Operation Log and Inspection Result for MHP

download Operation Log and Inspection Result for MHP

of 7

Transcript of Operation Log and Inspection Result for MHP

  • 8/3/2019 Operation Log and Inspection Result for MHP

    1/7

    Fill Numeric Characters Clearly ! Sample of

    Operation Log & Inspection Result (1/4)

    OPERATION LOG (Hydro Supply) Month: Year:

    R-N Y-N B-N R-Y Y-B B-R IR IY IB

    [V] [V] [V] [V] [V] [V] [KW] [A] [A] [A] [per min]

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    REMARKSDate Time

    Date Time

    " 1

    Voltage

    Output

    Current

    Rotation

    Comments of Operator

    Hydro Supply

  • 8/3/2019 Operation Log and Inspection Result for MHP

    2/7

    Hz [kWh] [Mpa]Frequency

    Generated

    Energy

    PressureGauge on

    Turbine

    Fill N i Ch Cl l ! S l f i h

  • 8/3/2019 Operation Log and Inspection Result for MHP

    3/7

    Fill Numeric Characters Clearly ! Sample of numeric chara

    Operation Log & Inspection Result (2/4)

    OPERATION LOG (Village Suppy) Month Year

    R-N Y-N B-N R-Y Y-B B-R IR IY IB[V] [V] [V] [V] [V] [V] [A] [A] [A] Hz [kWh]

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:0017:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:0017:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    7:00

    11:0017:00

    7:00

    11:00

    17:00

    7:00

    11:00

    17:00

    REMARKSDate Time Comments of Operator

    " 1 2 3 4 5 6 7 8

    Date Time

    Hydro Supply

    Voltage Current

    Frequency

    Village

    Supply

    Energy

  • 8/3/2019 Operation Log and Inspection Result for MHP

    4/7

    [Houses] [kW]

    Village

    Supplypower

    Number ofConsumers

    F aracters ear y n B oc Letters amp e o oc etters

  • 8/3/2019 Operation Log and Inspection Result for MHP

    5/7

    F aracters ear y n B oc Letters amp e o oc etters

    Operation Log & Inspection Result (3/4) "ABCDEFGHIJKLMN"

    Month: Year:

    Inspect according to "List of Inspection Items", and fill the problem of each structure in the following column if an

    [m] [m/sec] [C]

    REMARKS

    Date Time

    Fill Characters Clearly in Block Letters !!

    River Water Intake Weir Inpspection Result for Civil Structure

    TimeDate

    Comments of Inspector/Inspection result that is not possible to write in the above column

    IntakeHeadrace

    Channel

    Sand Settling

    Basin

    Penstock Power Station

    RIVER WATER & CIVIL STRUCTURES

    Inspec-

    tion Class

    Water

    Height

    Water

    Discharge

    Water

    Temp.

  • 8/3/2019 Operation Log and Inspection Result for MHP

    6/7

    Tailrace

    F aracters ear y n B oc Letters amp e o oc etters

  • 8/3/2019 Operation Log and Inspection Result for MHP

    7/7

    F aracters ear y n B oc Letters amp e o oc etters

    Operation Log & Inspection Result (4/4) "ABCDEFGHIJKLMN"

    GENERATING & TRANSMISSION FACILITIES Month: Year:

    Inspect according to "List of Inspection Items", and fill the problem of each facilities in the following column if any

    Inlet Valve Water Turbine Generator Ballast Load Power Board Transformer Transmission

    Line

    REMARKS

    Date Time

    Fill Characters Clearl in Block Letters !!

    Comments of Inspector/Inspection result that is not possible to write in the above column

    Inspec-

    tion Class

    Date

    Inspection Result for Generating and Transmission Facilities