Brine/Water Heat PumpsProfessional
Operating ManualSWP
83053700gUK – Translation into English of the original German operating manual
2 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Please read firstThis operating manual provides important information on the handling of the unit. It is an integral part of the product and must be stored so that it is accessible in the immediate vicinity of the unit. It must remain available throughout the entire service life of the unit. It must be handed over to subsequent owners or users of the unit.
In addition to this operating manual, you must also have the operating manual for the heating and heat pump regulator and the operating manual for your heat pump.
Read the operating manual before working on or operating the unit. This applies in particular to the chapter on safety. Always follow all instructions completely and without restrictions.
It is possible that this operating manual may contain instructions that seem incomprehensible or unclear. In the event of any questions or if any details are unclear, contact the factory customer service department or the manufacturer’s local partner.
Since this operating manual was written for several different models of the unit, always comply with the parameters for the respective model.
This operating manual is intended only for persons assigned to work on or operate the unit. Treat all constituent parts confidentially. The information contained herein is protected by copyright. No part of this manual may be reproduced, transmitted, copied, stored in electronic data systems or translated into another language, either wholly or in part, without the express written permission of the manufacturer.
SymbolsThe following symbols are used in the operating manual. They have the following meaning:
Information for uers.
Information or instructions for qualified technicians.
DANGER! Indicates a direct impending danger
resulting in severe injuries or death.
WARNING! Indicates a potentially dangerous situation
that could result in serious injuries or death.
CAUTION! Indicates a potentially dangerous situation
that could result in medium or slight injuries.
ATTENTION. Indicates a potentially dangerous situation, which
could result in property damage.
NOTE. Emphasized information.
€
ENERGY SAVING TIP Indicates suggestions that help to save energy,
raw materials and costs.
Reference to other sections of the operating manual.
Reference to other documents of the manufacturer.
3Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Content
INFORMATION FOR USERS AND QUALIFIED PERSONNEL
PLEASE READ FIRST ..................................................................2
SYMBOLS .....................................................................................2
INTENDED USE ..........................................................................4
DISCLAIMER................................................................................4
EC CONFORMITY .....................................................................4
SAFETY .........................................................................................4
CUSTOMER SERVICE ................................................................5
WARRANTY / GUARANTEE ....................................................5
DISPOSAL ....................................................................................5
OPERATING PRINCIPLE OF HEAT PUMPS ..........................5
AREA OF UTILISATION ............................................................5
HEAT METERING .......................................................................6
OPERATION ................................................................................6
COOLING ....................................................................................6
CARE OF THE UNIT ..................................................................7
MAINTENANCE OF THE UNIT ..............................................7Cleaning and flushing of unit components ........................8
MALFUNCTIONS .......................................................................8
INSTRUCTIONS FOR QUALIFIED TECHNICIANS
SCOPE OF DELIVERY ................................................................8Main components ..................................................................9
INSTALLATION ..........................................................................9Installation area .....................................................................9Transport to installation location ....................................10Installation ............................................................................10
INSTALLATION OF THE HYDRAULIC CONNECTIONS ................................................................ 11Buffer tank ........................................................................... 11Domestic water heating ..................................................... 11Domestic hot water tank .................................................. 11Installing the housing ..........................................................13
ELECTRICAL CONNECTIONS .............................................15
INSTALLATION OF THE CONTROL ELEMENT ............... 17
FLUSHING AND FILLING THE UNIT ..................................18flushing and filling the heat source ...................................18flushing and filling the heating circuit ..............................18Water quality .......................................................................18
INSULATING THE HYDRAULIC CONNECTIONS ..........20
COMMISSIONING ...................................................................20
DISMANTLING .........................................................................21
TECHNICAL DATA / SCOPE OF DELIVERYBrine operation ..................................................................22Water operation .................................................................24
PERFORMANCE CURVESHeating capacity/COP / power consumption / heat pump pressure loss
Brine operationSWP 371 ...............................................................................26SWP 451 ...............................................................................27SWP 581 ...............................................................................28SWP 691 ...............................................................................29SWP 291H ............................................................................30SWP 561H ............................................................................31Water operationSWP 371 ...............................................................................32SWP 451 ...............................................................................33SWP 581 ...............................................................................34SWP 691 ...............................................................................35SWP 291H ............................................................................36SWP 561H ............................................................................37
DIMENSIONAL DRAWINGS AND INSTALLATION PLANSSWP 371 – SWP 691Dimensional drawings - moving dimensions ...................38Dimensional drawings with housing ................................39SWP 291H – SWP 561HDimensional drawings - moving dimensions .................. 40Dimensional drawings with housing ................................41Installation plansInstallation plan 1 ................................................................42Installation plan 2 ................................................................43
HYDRAULIC INTEGRATIONSeparate buffer tank .......................................................... 44Legend Hydraulic integration ............................................45
TERMINAL DIAGRAM .............................................................46
CIRCUIT DIAGRAMSSWP 371 / SWP 451 ...........................................................47SWP 581 / SWP 691 / SWP 561H .....................................50SWP 291H ............................................................................53
EC DECLARATION OF CONFORMITY ..............................59
4 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Intended useThe unit may be used only for the intended purpose. This means:
• For heating.
• For domestic water heating.
• For cooling (active + passive through external hydraulics)
The unit may be operated only within its technical parameters.
Overview “Technical data / scope of delivery”.
NOTE. Notify the responsible power supply company of
the use of a heat pump or heat pump system.
DisclaimerThe manufacturer is not liable for losses resulting from any use of the unit which is not its intended use.
The manufacturer’s liability also expires:
• If work is carried out on the unit and its components contrary to the instructions in this operating manual.
• If work is improperly carried out on the unit and its components.
• If work is carried out on the unit which is not described in this operating manual, and this work has not been explicitly approved by the manufacturer in writing.
• If the unit or components in the unit have been altered, modified or removed without the explicit written consent of the manufacturer.
EC conformityThe unit bears the CE mark of conformity.
EC declaration of conformity
SafetyThe unit is safe to operate for its intended use. The construction and design of the unit conform to current state of the art standards, all relevant DIN/VDE regulations and all relevant safety regulations.
Every person who performs work on the unit must have read and understood the operating manual prior to starting any work. This also applies if the respective person has already worked with such a unit or a similar unit or has been trained by the manufacturer.
Every person who performs work on the unit must comply with the applicable accident prevention and safety regulations. This applies in particular to the wearing of personal safety gear.
DANGER! Risk of fatal injury due to electric shock! All electrical connections must be carried
out by qualified electricians only.
Before opening the unit, disconnect the system from the power supply and prevent it from being switched back on!
WARNING! Only qualified personnel (trained heating,
cooling and refrigerant engineers and electricians) may carry out work on the unit and its components.
WARNING! Observe safety labels on and in the unit.
WARNING! Unit contains refrigerants! Leaking refrigerant could result in
personal injury or material damage. Therefore:
– Switch off unit– Thoroughly ventilate installation room– Notify the manufacturer’s authorised
service centre
CAUTION. For safety reasons: Never disconnect the unit from the power
supply, unless the unit is being opened.
5Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Customer serviceFor technical assistance, please contact your qualified technician or the manufacturer’s local service partner.
For a current list and additional partners of the manufac-turer, please visit
DE: www.alpha-innotec.de
EU: www.alpha-innotec.com
Warranty / GuaranteeFor warranty and guarantee conditions, please refer to the purchase documents.
NOTE. Please contact your dealer about all matters
concerning warranties and guarantees.
DisposalWhen decommissioning the old unit, always comply with local applicable laws, directives and standards concerning the recovery, recycling and disposal of materials and components of cooling units.
“Dismantling”.
Operating principle of heat pumps
Heat pumps operate on the same principle as a refrigerator: same technology, only with reversed benefits. The refrigerator extracts heat from foods, which is released into the room through fins on the back.
The heat pump extracts heat from our environment: air, earth or ground water. The extracted heat is conditioned in the unit and supplied to the heating water. Even when it is extremely cold outside, the heat pump draws enough heat to heat a house.
Example: drawing of a brine/water heat pump with floor heating:
4/4 = usable energyapprox. 3/4 = environmental energyapprox. 1⁄4 = external electrical
energy
Area of utilisationTaking into consideration the ambient conditions, limits of application and the applicable regulations, every heat pump can be utilised in new or existing heating systems.
Overview “Technical data / scope of delivery”.
6 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Heat meteringIn addition to proof of the unit’s efficiency, the EEWaermeG also requires heat metering (hereafter referred to as HQR). Heat metering is mandatory for air/water heat pumps. Heat metering for brine/water and water/water heat pumps only have to be installed for a flow temperature ≥ 35 °C. The heat metering must record the total thermal energy released (heating and domestic hot water) in the building. In heat pumps with heat metering, the analysis is carried out by the regulator. The regulator displays the thermal energy discharged in the heating system in kWh.
OperationYour decision to purchase a heat pump or a heat pump system is a long-term contribution to protecting the environment through low emissions and reduced primary energy use.
To ensure that your heat pump or heat pump system operates efficiently and ecologically, the following are especially important:
€ ENERGY SAVING TIP Avoid unnecessarily high flow temperatures.
A lower flow temperature on the hot water side increases the efficiency of the system.
€ ENERGY SAVING TIP Preferably use purge ventilation. Compared to
continuously open windows, it is better to air rooms by fully opening windows for a short period, two to three times a day (so-called “rapid” or “purge” ventilation); this reduces energy consumption and your heating bill.
You can operate and control the heat pump system with the control element of the heating and heat pump regulator.
NOTE. Make sure that the control settings are correct.
Operating manual of the heating and heat pump regulator.
CoolingThere are two ways to use the heat pump for air condi-tioning in rooms, through: „passive cooling“ and „active cooling“.The main difference is the compressor operation. Whi-le the compressor is not needed for passive cooling, i.e. it is passive, the compressor operates during active coo-ling, i.e. it is active.Another difference is that both passive and active coo-ling is possible with the ground and groundwater heat sources. But only active cooling is possible with the out-side air heat source.Passive cooling is the more cost-effective option. Lowe-ring the temperature by 3-4 K is often fully sufficient to produce a comfortable room temperature in the sum-mer.Whereas higher cooling output is possible with active cooling.Passive cooling uses the fact that the ground and ground-water, from a depth of around 8 metres, are more or less a constant temperature all year round and in the summer are around 9 °C to 10 °C cooler than the out-side air or the interior rooms.This temperature difference is sufficient to cool a buil-ding with energy from the ground and groundwater. Ad-ditional fan coils, cooling ceilings, underfloor heating and thermo active building systems (embedding cooling pi-pes), such as concrete core thermal activation, can be used for direct cooling.
ATTENTION By cooling with low flow temperatures, conden-
sate can be expected to form on the heat distri-bution system as the temperature falls below the dew point. If the heat distribution system is not designed for these operating conditions, it must be protected by appropriate safety devices, e.g. dew point monitor (purchasable accessory).
NOTICE If the heating surfaces are used for heating and
cooling, the control valves must be suitable for heating and cooling.
In addition, a dew-point monitor should be used for cooling.
NOTE Use recommended accessory dew point moni-
tors.
7Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
THE ROOM THERMOSTAT OF THE COOLING FUNCTION (PURCHASABLE ACCESSORIES, OPTIONAL)
The room thermostat is used to release and to switch off the cooling function:
I Cooling function switched on Cooling function off
USE OF THE COOLING FUNCTION
The heating and heat pump regulation program activates the cooling function only if the following conditions are fulfilled:
• Heat pump type with integrated cooling function.
• Room thermostat of the cooling function is swit-ched on.
• Temperature of the heat source is ≥ +5 °C.
• Heat pump is currently not being used for „heating“ nor for „domestic water heating“.If the heat pump control program sends the “domestic water hea-ting” request to the heat pump, the cooling function of the heat pump stops automatically for the dura-tion of the domestic water heating.
• The „Automatic“ setting is selected under the „Cooling mode“ heading.
• The outside temperature release set at the control is exceeded.
Operating manual of the heating and heat pump regulator.
The cooling function can be used in two variants:
Variant 1:
Manual switching from heating to cooling mode (and vice versa). This uses a fixed pre-set flow temperature.
Operating manual of the heating and heat pump controller.
Variant 2:
Automatic switching from heating to cooling mode (and vice versa). This variant can operate using a cooling curve.
NOTE Variant 2 is only possible if the expansion board
(purchasable accessories) is installed in the hea-ting and heat pump controller.
Expansion board operating manual
Care of the unitThe outer surfaces of the unit can be cleaned with a damp cloth and standard cleaning products.
Do not use cleaning or care products that contain abrasives, acids and/or chlorine. Such products would destroy the surfaces and could also damage the technical components of the unit.
Maintenance of the unitThe cooling circuit of the heat pump requires no regu-lar maintenance.
According to EU regulation (EC) 517/2014, leak inspections and maintenance of a log book are required by law for certain heat pumps!
Log book for heat pumps, Section “Information on use of the log book”.
The components of the heating circuit and the heat source (valves, expansion vessels, circulating pumps, filters, dirt traps) should be inspected and cleaned as needed - at the very least annually - by qualified personnel (heating or cooling system fitters).
It is best to arrange a maintenance agreement with a heating installation company. The company will arrange for the required maintenance at regular intervals.
8 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
CLEANING AND FLUSHING OF UNIT COMPONENTS
CAUTION! Unit components may be cleaned
and flushed only by customer service personnel authorised by the manufacturer. Use only liquids recommended by the manufacturer.
Flushing of the liquefier with chemical cleaning agents must be followed by neutralisation of residue and intensive flushing with water. Always observe the technical data of the manufacturer of the heat exchanger.
MalfunctionsIn the event of a fault, you can read out the cause of the fault from the diagnostic program of the heating and heat pump regulator.
Operating manual of the heating and heat pump regulator.
WARNING! Only customer service personnel
authorised by the manufacturer may carry out service and repair work on the components of the unit.
Scope of deliveryExample of scope of delivery:
Size 1:
As delivered:
1 Heat pump = complete indoor unit2 Transport frame3 Facing panels placed to
the side (5 panels)4 Insulation panel, which is then
pushed under the baseplate (sound insulation)
5 Pre-fitted adjustable feet (4)6 Spacer blocks (4), which can be
unscrewed after installation7 Extra box with accessories (indoors)8 Profile rails
Complete the following first:
Check the delivery for outwardly visible signs of damage…
Check that nothing is missing from the scope of supply…
Any defects or incorrect deliveries must be reported immediately.
NOTE. Note the unit model.
Overview “Technical data / scope of delivery”.
9Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
MAIN COMPONENTS
1 condenser2 compressor3 evaporator
InstallationObserve the following when performing all work:
NOTE. Always comply with the applicable local accident
prevention regulations, statutory regulations, ordinances, guidelines and directives.
WARNING! The heat pump or heat pump system
may only be installed and assembled by qualified personnel!
NOTE. Observe the sound levels of the respective
model.
Overview “Technical data / scope of delivery”, “Sound” section.
INSTALLATION AREA
ATTENTION. Install the heat pump only indoors. The installation room must be frost-free and
dry.
WARNING! Please note and follow the respective
relevant local standards, directives and regulations applicable, especially the minimum volume necessary depending on the refrigerant capacity of the relevant heat pump system (EN 378-1).
Refrigerant Limit
R 134a 0.25 kg/m³
R 404A 0.48 kg/m³
R 407C 0.31 kg/m³
R 410A 0.44 kg/m³
Overview “Technical data / scope of delivery”, “General unit data” section.
Minimum volume = Refrigerant capacity [kg]
Limit [kg/m³]
NOTE. If several heat pumps of the same type
are installed, only one heat pump must be considered.
If several heat pumps of different types are installed, the heat pump with the largest refrigerant capacity must be considered.
10 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
TRANSPORT TO INSTALLATION LOCATION
Before transporting the heat pump to the final installation location the packaging and wooden frame can be dismantled.
To do this, remove the facing panels on the long sides, undo the wooden boards and remove the two machine screws (M8) in each of the sides.
You can now lift the unit with the help of a pallet truck or fork lift truck and transport it to its final installation location.
NOTE. The unit has ground clearance for easy access
from all sides
NOTE. The baseplate is 76 cm wide, so that the heat
pump can be transported through a standard door opening.
NOTE. Keep the components enclosed in the scope of
delivery in a safe place until the assembly.
Always comply with the following safety information during transport:
CAUTION! Wear safety gloves.
WARNING! Several people are required to transport
the unit. Do not underestimate the weight of the unit.
Overview “Technical data / scope of delivery”, “General unit data” section.
ATTENTION. Never use components and hydraulic
connections on the unit for purposes of transport.
ATTENTION. Do not tilt the unit more than a maximum of 45°
(in any direction).
INSTALLATION
WARNING! Several people are required to install the
unit.
NOTE. Take into account the size of the unit.
Overview “Technical data / scope of delivery”, “General unit data” section.
NOTE. Always follow the installation plan for the
respective model. Note the size and minimum clearances.
Installation plan for respective model.
ATTENTION. The heat pump must be installed on a firm,
horizontal surface. Make sure that the foundation is designed for the weight of the heat pump.
Do not use a rigid foam boiler pedestal!
Overview “Technical data/scope of delivery”, “General unit data” section.
11Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
NOTE. Set up the unit so that the operating side is
accessible at all times!
ATTENTION. Do not tilt the unit more than a maximum of 45°
(in any direction).
Lower the basic heat pump module on the 4 wooden transport blocks in its final installation location. Now use the vibration-decoupling, adjustable machine feet to align the unit horizontally. Ensure the distance from the finished floor level to the top of the heat pump baseplate is 170 mm. Lock this setting by locking the nuts.
The four transport blocks (each with 2 universal wood screws) must then be removed.
Installation of the hydraulic connections
BUFFER TANK
The hydraulic connection of the heat pump requires a buffer tank in the heating circuit. The required volume of the buffer tank is calculated based on the following formula:
VBuffer tank =minimum flow rate of heat circuit volume flow / hour
10
For the minimum flow rate of the heat circuit volume flow, see overview “Technical data/Scope of delivery”, “Heating circuit” section.
DOMESTIC WATER HEATING
The domestic water heating with the heat pump requires an additional hot water circuit, parallel to the heating circuit. When installing, make sure that the domestic hot water charge is not fed through the buffer tank of the heating circuit.
“Hydraulic connection” instructions.
DOMESTIC HOT WATER TANK
If the heat pump is to be used for domestic water heating, you must integrate special domestic hot water tanks in the heat pump system. Choose a storage volume so that the required quantity of hot water is available even during a power cut.
NOTE: The heat exchanger surface of the domestic hot
water tank must be dimensioned so that the heating capacity of the heat pump is transferred with minimum spread.
We offer a variety of domestic hot water tanks for you to choose from. They are optimised for use with your heat pump.
ATTENTION. Connect the unit to the heating circuit according
to the hydraulic diagram for the respective model.
“Hydraulic connection” instructions.
12 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
ATTENTION. The heat source system must be designed
according to the specifications of the planning manual.
Planning manual and “Hydraulic connection” documents.
NOTE: Check to make sure that the diameters and
lengths of the pipes for the heating circuit and the heat source are sufficiently dimensioned.
NOTE: Circulating pumps, which pump the volume flow
through the heat pump, must be designed as multi-stage pumps. They must at least provide the minimum throughput rate required for your model.
In the case of heat source pumps, the viscosity of the brine liquid must also be taken into account!
Overview “Technical data / scope of delivery”, “Heat circuit” and “Heat source” sections.
ATTENTION. The hydraulic system must be equipped with
a buffer tank, the required volume of which depends on the model of your unit.
ATTENTION. When installing the connections, always secure
the connections on the unit against twisting, in order to prevent damage to the components inside the unit.
The following steps are to be carried out on all 4 hydraulic connections of the heat pump:
Push the insulation elements included in the scope of delivery onto the plate heat exchanger
Position the back panel of the heat pump on the basic heat pump module
Connect the piece of pipe supplied to the threaded flange and insulate it with the enclosed insulating hose
Connect the connectors to the connection clip included in the scope of supply to the corresponding connection on the heat pump.
13Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Use the insulating tape supplied to insulate the connection clip. Use the enclosed fastening materials to additionally fix the insulation.
NOTE: We recommend completing step after the
leak test.
NOTE: The heat source and heating side must be
insulated from the heat pump; to this end we recommend using the IPFK hydraulic connection set in our range of products (not included in the scope of delivery).
Install shut-off devices at the heating circuit.
Install shut-off devices at the heat source.
Place a bleeder at the highest point of the heat source in the heat source outlet…
We recommend installing a dirt filter (screen size 0.9 mm) on the heat source inlet connection…
The hot water and heat source connections are marked accordingly on the unit.
For the positioning of the connections, please refer to the dimensioned drawing for the respective model.
INSTALLING THE HOUSING
NOTE. Remove the protective film from all facing panels.
NOTE. The screws for installing the heat pump housing
are included in the scope of delivery.
Position the insulation included in the scope of delivery under the baseplate.
NOTE. Before screwing on the side panels, feed the patch
cable and + LIN bus cable through the rear panel!
see “electrical connection work”
Screw the two side panels onto the back panel using 3 screws for each:
Mount the profile rail onto the front of the unit, between the two side panels, using 2 screws for each side.
1 Profile rail2 Screw
14 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Align the facing with the baseplate as shown in the following sketch
28
28
28
Secure and fix the facing on the profile rail using the fastening materials included in the scope of delivery (2 x 10mm anchors and 2 x M8 hanger bolts). Twist the hanger bolt into the floor up to the start of the thread.
1 hanger bolt with anchor
Align the insulating board under the unit with the
middle of the unit (see ).
Fix the housing cover onto the rear panel (5 screws):
and the two side panels (2 screws each) onto the front:
The front panel can now be hung into the clips provided at the bottom
and locked by means of the two quarter-turn screws.
Glue the insulating half-shells included in the scope of delivery around the pipe pieces in the rear panel.
15Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Electrical connectionsThe following applies to all work to be done:
DANGER! Risk of fatal injury due to electric shock! All electrical connections must be carried
out by qualified electricians only.
Before opening the unit, disconnect the system from the power supply and prevent it from being switched back on!
WARNING! During installation and while carrying out
electrical work, comply with the relevant EN-, VDE and/or local safety regulations.
Comply with technical connection requirements of the responsible power supply company (if required by the latter)!
NOTE. All cables must be fed through the openings in
the back panel!
The front panel is hung in at the bottom and is held in place at the top by 2 quarter-turn screws.
1 Quarter-turn screws
Open the quarter-turn screws of the front panel by turning them through 90° anticlockwise…
Lift out front panel and set aside in a safe place…
1 Electrical switch cabinet
Open the unit’s electrical switch cabinet: Undo the 6 screws slightly, in order to unhook the
cover panel by lifting it slightly…
Several openings are provided at the back of the unit for passing through the cables:
NOTE. When laying the cable, ensure that unshielded
power supply cables and shielded cables (LIN bus) are laid separately from each other.
NOTE. LIN bus length may not be increased. However,
they can be shortened.
For further details, see “installation plan”
1 Electric cable penetration
2 Penetration, LIN bus and patch cable for Luxtronik 2.0 regulator
16 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
The external electric cables to be provided must be fed through the grommets cut out in the bottom of the rear panel and then fed into the electrical switch cabinet by means of the cable duct, which is integrated into the baseplate of the heat pump.
1 Cable duct
The cables laid in the switch cabinet for the regulator (patch cable, LIN bus) must be fed through the grommet cut out in the bottom of the rear panel.
Make electrical connections according to the terminal diagram…
“Terminal diagrams” for respective model.
ATTENTION. Ensure clockwise rotary field of the load power
supply (compressor). Operation with the incorrect rotary direction of
the compressor can cause serious, irreparable damage to the compressor.
ATTENTION. The power supply for the heat pump must be
equipped with an all-pole automatic circuit-breaker with at least 3mm contact spacing to IEC 60947-2.
Note the level of the tripping current.
Overview “Technical data / scope of delivery”, “Electrics” section.
1 Control voltage connection2 Compressor output connection3 Regulator board
NOTE. The control element of the heat and heat pump
regulator can be connected to a computer or network using a suitable network cable, enabling the heating and heat pump regulator to be controlled remotely from there.
If such a connection is required, lay a shielded network cable (category 6, with RJ-45 connector) up to the control element while carrying out the electrical connection work.
After completion of all electrical installation work, close the switch cabinet inside the unit.
Screw on the front panel of the unit if no further installation work inside the unit is to be performed immediately.
17Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Installation of the control element
NOTE. Note the distance between the control element
and the unit.
For further details, see “installation plan”
Control element for wall-mounting
Fasten the wall bracket using the assembly materials included in the scope of delivery.
There are 4 fixing hooks on the back of the control element.
Hang the control element on the wall bracket using the 4 fixing hooks and push down until it latches into position.
1 Shielded terminal for LIN bus cable/strain relief
2 Strain relief
Connection of patch cable and LIN bus cable to the regulator (via the strain relief):
1 Patch cable to the network link2 LIN bus to the regulator board in the unit3 Patch cable to the regulator
board in the unit
If the work on the heat pump regulator has been completed, the cover can be clipped onto the wall bracket.
+ =
NOTE. A connection to a computer or a network can
be installed via the left bushing on the bottom of the control element, thus allowing the heating and heat pump regulator to be controlled remotely. This requires that a shielded network cable was laid up to the heat pump regulator during the electrical connection work.
Operating manual for the heating and heat pump regulator, version “Qualified heating engineers”, “Web server” section.
NOTE. The network cable can be exchanged at any
time. In order to be able to connect it, the screen must first be removed.
18 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Flushing and filling the unit
CAUTION. The system must be absolutely free from air
before commissioning.
FLUSHING AND FILLING THE HEAT SOURCE
Contamination and deposits in the heat source can cause malfunctions.
ATTENTION. Before flushing and filling the heat source the
drain pipe of the safety valve must be connected - Important: do not discharge into the drains (anti-freeze mixture)!.
NOTE The following antifreezes are approved for the
brine circuit:
• Monopropylene glycol
• Monoethylene glycol
• Ethanol
• Methanol
ATTENTION Ensure that the (pipe) materials, seals and other
components used on site are made of materials that are compatible with the antifreeze used!
WARNING! Methanol and ethanol can evaporate, gi-
ving off flammable and explosive gases. Therefore, the relevant antifreeze safety regulations must be noted and followed!
Flush heat source system thoroughly.
Thoroughly mix the anti-freeze, available as an accessory, with water with the required ratio. Add only anti-freeze mixed with water to the heat source.
ATTENTION. The concentration of anti-freeze in the water
must be at the level specified for your model.
Overview “Technical data / scope of delivery”, “Heat source” section.
Check the concentration of the anti-freeze in the mixture…
Fill heat source with the anti-freeze mixture…
Bleed the heat source.
FLUSHING AND FILLING THE HEATING CIRCUIT
WATER QUALITY
OF THE FILL AND ADDITIONAL WATER IN HOT WATER HEATING SYSTEMS ACCORDING TO VDI 2035 PART I AND II
Use of modern, energy-efficient heat pump systems is becoming increasingly widespread. Their ingenious technology enables these systems to achieve very good efficiencies. The decreasing space available for heat generators has led to the development of compact units with increasingly smaller cross-sections and high capacities. This means the complexity of the systems and the material diversity are also increasing, which plays an important role especially in their corrosion behaviour. The heating water not only affects the efficiency of the system, but also the life of the heat generator and the heating components of a system.
The guide values of VDI 2035 Part I and Part II must therefore be complied with as minimum requirements for proper operation of the systems. Our practical experience has shown that the safest and most trouble-free running of the systems is achieved with so-called low-salt operation.
VDI 2035 Part I gives important information and recommendations regarding scaling and its prevention in heating and domestic hot water heating systems.
VDI 2035 Part II primarily deals with the requirements for reducing heating water corrosion in hot water heating systems.
PRINCIPLES OF PART I AND PART II
The occurrence of scaling and corrosion damage in hot water heating systems is low, if
- proper planning and commissioning is carried out
- the system is closed in corrosion terms
- adequately dimensioned pressurising is integrated
- the guide values for the heating water are complied with
19Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
- and regular servicing and maintenance are carried out.
A system log should be kept, in which the relevant planning data is entered (VDI 2035).
DAMAGE THAT CAN OCCUR IN CASE OF NON-COMPLIANCE
- Malfunctions and the failure of components (e.g. pumps, valves)
- Internal and external leaks (e.g. from heat exchangers)
- Cross-section reduction and blockaging of components (e.g. heat exchanger, pipes, pumps)
- Material fatigue
- Gas bubbles and gas cushion formation (cavitation)
- Negative effect on heat transfer (formation of coatings, deposits) and associated noises (e.g. boiling noises, flow noises)
LIMESCALE – THE ENERGY KILLER
Filling with untreated drinking water inevitably leads to the precipitation of all calcium as scale. The consequence: limescale deposits form on the heat transfer surfaces of the heating. The efficiency falls and the energy costs rise. A rule of thumb is that 1 millimetre of limescale deposit causes an energy loss of 10%. In extreme cases it can even cause damage to the heat exchangers.
WATER SOFTENING TO VDI 2035 – PART I
If the water is softened before the heating is filled, in accordance with the VDI 2035 guidelines, no scale can form. This effectively and permanently prevents limescale deposits and the resulting negative effects on the entire heating system.
CORROSION – AN UNDERESTIMATED PROBLEM
VDI 2035, Part II, deals with the problem of corrosion. Softening the heating water can prove to be insufficient. The pH value can significantly exceed the limit of 10. pH values higher than 11 can set in, which even damage rubber seals. The VDI 2035, Part 1 guidelines are fulfilled, however, VDI 2035, Part 2 suggests a pH value between 8.2 and maximum 10.
If aluminium materials are used, which is the case in many modern heating systems, a pH value of 8.5 must not be exceeded, because otherwise there is a threat of corrosion – and aluminium is attacked without the presence of oxygen. Therefore, apart from softening
the heating fill and additional water, the heating water should also be appropriately conditioned. This is the only way to comply with the VDI 2035 requirements and the recommendations and installation instructions of the heat pump manufacturer.
Part 2 of VDI 2035 also points out the reduction in total salt content (conductivity). The risk of corrosion is far lower if deionised water is used than is the case if the system is operated with salty, i.e. softened water.
Even if the water has been softened beforehand, it contains dissolved, corrosion-promoting salts, which act as electrolytes due to the use of different materials in the heating system and therefore accelerate corrosion processes. This can ultimately result in pitting.
ON THE SAFE SIDE WITH LOW-SALT OPERATION
The problems listed above do not occur at all with low-salt operation, as neither corrosive salts such as sulphates, chlorides and nitrates nor alkalising sodium hydrogen carbonate are in the heating water. The corrosive properties of deionised water are very low and in addition, fur cannot form in the boiler. This is the ideal approach for closed heating circuits, in particular, because low oxygen input into the heating circuit can also be tolerated.
In general, when the system is filled with deionised water, the pH value sets itself within the ideal range due to „self-alkalinisation“. If necessary, a pH value of 8.2 can be very easily alkalised by adding chemicals. In this way, optimum protection of the entire heating system is achieved.
MONITORING
Analytical recording and monitoring of the relevant water values and the added active conditioning substances is of decisive importance. Therefore, they should be monitored regularly using appropriate water test equipment.
ATTENTION. Before flushing and filling the heating circuit, the
drain pipe of the safety valve must be connected.
Flush heating circuit system thoroughly.
Fill heating circuit…
Bleed heating circuit.
20 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Insulating the hydraulic connections
NOTE. Insulate the heating circuit and the heat source
according to relevant local standards and guidelines.
Check all hydraulic connections for leaks. Perform leak test…
Insulate all connections, vibration isolation, connections and pipes of the heating circuit and the heat source. Insulate the heat source so that it is vapour-diffusion tight.
Commissioning
NOTE. The commissioning has to be in the heating
mode.
Carry out a thorough installation check and work through the general checklist…
Manufacturer’s homepage.
By checking the installation you prevent damage to the heat pump system, which could be caused by work carried out improperly.
Check that…
• clockwise rotary field of the load power supply (compressor) is ensured.
• The heat pump installation and assembly have been carried out according to the requirements of this operating manual.
• the electrical installation work has been completed properly.
• The power supply for the heat pump must be equipped with an all-pole automatic circuit-breaker with at least 3 mm contact spacing to IEC 60947-2.
• The heating circuit is flushed, filled and thoroughly vented.
• All valves and shut-off devices of the heating circuit are open.
• All pipe systems and components of the system are leaktight.
Carefully fill out and sign the completion report for heat pump systems...
Manufacturer’s homepage.
Within Germany and Austria: Send completion report for heat pump systems
and general checklist to the manufacturer’s factory customer service department…
In other countries: Send completion report for heat pump systems
and general checklist to the manufacturer’s local partner…
The heat pump system is commissioned by customer service personnel authorised by the manufacturer. There is a fee for starting up!
21Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Dismantling
DANGER! Risk of fatal injury due to electric shock! Electrical connections may be installed
only by qualified electricians.
Before opening the unit, disconnect the system from the power supply and prevent it from being switched back on!
WARNING! Only qualified heating or cooling system
personnel are allowed to remove the unit from the system and dismantle the unit.
ATTENTION. The anti-freeze mixture of the heat source must
not be allowed to enter the sewer system. Collect anti-freeze mixture and dispose of
properly.
ATTENTION. Recycle or ensure proper disposal of unit
components, refrigerants and oil according to the relevant regulations, standards and guidelines.
REMOVAL OF THE BUFFER BATTERY
ATTENTION. Before scrapping the heating and heat pump
regulator, remove the buffer battery on the processor board. The battery can be pushed out using a screwdriver. Dispose of battery and electronic components in an environmentally friendly way.
22 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Device designationHeat pump type Brine/Water ı Air/Water ı Water/Water • relevant ı — not relevant
Installation location Indoors ı Outdoors • relevant ı — not relevant
Conformity CE
Power data Heating power/COP at
B0/W35 Standard point as per EN14511 2 Compressors 1 Compressor
kW ı … kW ı …
B0/W45 Standard point as per EN14511 2 Compressors 1 Compressor
kW ı … kW ı …
B7/W35 Standard point as per EN14511 2 Compressors 1 Compressor
kW ı … kW ı …
B0/W50 Standard point as per EN14511 2 Compressors 1 Compressor
kW ı … kW ı …
Operating limits Heat circuit °C
Heat source °C
Additional operating points …
Noise Sound pressure level at 1m gap around the machine averaged (in free field) dB(A)
Sound power level as per EN12102 dB
Heat source Volumetric flow: minimum throughput ı nominal throughput ı maximum throughput l/h
Pressure loss in heat pump ∆p ı Volumetric flow bar ı l/h
Recommended brine circulating pump …
Total compression of the recommended pump at nominal brine volumetric flow bar ı l/h
Antifreeze Monoethylene glycol
Minimum concentration ı frostproof to % ı °C
Heat circuit Volumetric flow: minimum throughput ı nominal throughput ı maximum throughput l/h
Pressure loss in heat pump ∆p ı Volumetric flow bar ı l/h
Free compression of heat pump ∆p ı Volumetric flow bar ı l/h
Temperature spread for B0/W35 K
General device data Earth (see dimensional diagram for the size indicated) Size
Total weight kg
Extra weight of construction unit 1 kg
Extra weight of construction unit 2 kg
Connections Heat circuit …
Heat source …
Refrigerant Refrigerant type ı Filling capacity … ı kg
Electrics Voltage code ı All-pole circuit breaker for pump *) … ı A
Voltage code ı Control voltage circuit breaker *) … ı A
Voltage code ı Electrical heating element circuit breaker *) ı A
Heat pump Effect. power consumption in the normal point B0/W35 as per EN14511: Power consumption ı Current consumption ı cosφ kW ı A ı …
Maximum machine current within the operating limits A
Starting current: direct ı with slow-starter A ı A
Protection type IP
Power of electrical heating element 3 ı 2 ı 1-phase kW ı kW ı kW
Components Circulating pump for heat circuit at nominal throughput: Power consumption ı Current consumption kW ı A
Circulating pump for heat source at nominal throughput: Power consumption ı Current consumption kW ı A
Setting range for motor protection switch of heat source circulating pump A
Passive cooling function Data only for devices with ID K: Cooling power at nominal volumetric flow rates (15 °C heat source, 25 °C hot water) kW
Safety devices Safety assembly for heat circuit ı Safety assembly for heat source in scope of supply: • yes — no
Heating and heat pump control in scope of supply: • yes — no
Electronic soft-starter integrated: • yes — no
Expansion vessels Heat source: Scope of supply ı Volume ı Supply pressure • yes — no ı l ı bar
Heat circuit: Scope of supply ı Volume ı Supply pressure • yes — no ı l ı bar
Overflow valve integrated: • yes — no
Vibration isolation Heat circuit ı Heat source in scope of supply: • yes — no
UK813198a *) Observe local regulations n.n. = cannot be demonstrated
Technical data / scope of delivery
23Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
SWP561H• ı — ı —
• ı —•
- 53,8 ı 4,50
- 52,9 ı 3,80
- 65,9 ı 5,20
- 52,1 ı 3,10
20 - 64 -5 - 25B0/W70
4459
9400 ı 12600 ı 191000,16 ı 12600
——•
25 ı -134400 ı 8900 ı 11200
0,12 ı 8900— ı —
5,01
521——
DN50 DIN2566DN50 DIN2566R134a ı 12,8
3~/PE/400V/50Hz ı C501~/N/PE/230V/50Hz ı B16
— ı —12,0 ı 27,80 ı 0,63
45,6310 ı 105
20— ı — ı —
— ı —— ı —
——
— ı —••
— ı —— ı —
——
813433a
SWP691• ı — ı —
• ı —•
- 68,5 ı 4,60
- 66,1 ı 3,60
- 84,1 ı 5,40
- 64,6 ı 2,90
20 - 60 -5 - 25B0/W65
4459
13000 ı 17300 ı 210000,16 ı 17300
——•
25 ı -135700 ı 11300 ı 14200
0,12 ı 11300— ı —
5,21
484——
DN50 DIN2566DN50 DIN2566R410A ı 13,4
3~/PE/400V/50Hz ı C501~/N/PE/230V/50Hz ı B16
— ı —14,9 ı 28,14 ı 0,75
48,5272 ı 85
20— ı — ı —
— ı —— ı —
——
— ı —••
— ı —— ı —
——
813431b
SWP291H• ı — ı —
• ı —•
- 25,9 ı 4,37
- 24,9 ı 3,46
- 31,5 ı 5,10
- 24,7 ı 2,80
20 - 64 -5 - 25B4/W70
4358
4900 ı 6500 ı 78000,16 ı 6500
——•
25 ı -132400 ı 4700 ı 5900
0,12 ı 4700— ı —
5,01
319——
DN50 DIN2566DN50 DIN2566
R134a ı 6,73~/PE/400V/50Hz ı C40
1~/N/PE/230V/50Hz ı B16— ı —
5,9 ı 15,16 ı 0,5634
174 ı 8220
— ı — ı —— ı —— ı —
——
— ı —••
— ı —— ı —
——
813432c
SWP581• ı — ı —
• ı —•
- 57,6 ı 4,80
- 55,8 ı 3,80
- 71,1 ı 5,80
- 54,1 ı 3,00
20 - 60 -5 - 25B0/W65
4257
10200 ı 13600 ı 163000,15 ı 13600
——•
25 ı -134900 ı 9700 ı 12200
0,12 ı 9700— ı —
5,11
441——
DN50 DIN2566DN50 DIN2566R410A ı 11,2
3~/PE/400V/50Hz ı C501~/N/PE/230V/50Hz ı B16
— ı —12,0 ı 22,16 ı 0,76
40225 ı 88
20— ı — ı —
— ı —— ı —
——
— ı —••
— ı —— ı —
——
813430b
SWP451• ı — ı —
• ı —•
- 45,0 ı 4,80
- 42,7 ı 3,70
- 55,0 ı 5,70
- 41,1 ı 2,90
20 - 58 -5 - 25B0/W65
4156
8100 ı 10800 ı 130000,15 ı 10800
——•
25 ı -133900 ı 7800 ı 9400
0,12 ı 7800— ı —
5,01
385——
DN50 DIN2566DN50 DIN2566R410A ı 8,2
3~/PE/400V/50Hz ı C401~/N/PE/230V/50Hz ı B16
— ı —9,4 ı 18,28 ı 0,72
34174 ı 37
20— ı — ı —
— ı —— ı —
——
— ı —••
— ı —— ı —
——
813429b
SWP371• ı — ı —
• ı —•
- 37,2 ı 4,80
- 35,8 ı 3,70
- 45,4 ı 5,60
- 34,8 ı 2,90
20 - 57 -5 - 25B3/W65
3954
6900 ı 9200 ı 111000,16 ı 9200
——•
25 ı -133200 ı 6400 ı 8000
0,12 ı 6400— ı —
5,01
371——
DN50 DIN2566DN50 DIN2566
R410A ı 7,23~/PE/400V/50Hz ı C321~/N/PE/230V/50Hz ı B16
— ı —7,8 ı 13,97 ı 0,8
31140 ı 26
20— ı — ı —
— ı —— ı —
——
— ı —••
— ı —— ı —
——
813428b
24 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Device designationHeat pump type Brine/Water ı Air/Water ı Water/Water • relevant ı — not relevant
Installation location Indoors ı Outdoors • relevant ı — not relevant
Conformity CE
Power data Heating power/COP at
W10/W35 Standard nominal conditions based on EN14511
2 Compressors 1 Compressor
kW ı … kW ı …
W10/W55 ** 2 Compressors 1 Compressor
kW ı … kW ı …
Operating limits Heat circuit °C
Heat source °C
Additional operating points …
Noise Sound pressure level at 1m gap around the machine averaged (in free field) dB(A)
Sound power level as per EN12102 dB
Heat source Volumetric flow: minimum throughput ı nominal throughput ı maximum throughput l/h
Pressure loss in heat pump ∆p ı Volumetric flow bar ı l/h
Recommended brine circulating pump …
Total compression of the recommended pump at nominal brine volumetric flow bar ı l/h
Antifreeze Monoethylene glycol
Minimum concentration ı frostproof to % ı °C
Heat circuit Volumetric flow: minimum throughput ı nominal throughput ı maximum throughput l/h
Pressure loss in heat pump ∆p ı Volumetric flow bar ı l/h
Free compression of heat pump ∆p ı Volumetric flow bar ı l/h
Temperature spread for W10/W35 K
General device data Earth (see dimensional diagram for the size indicated) Size
Total weight kg
Extra weight of construction unit 1 kg
Extra weight of construction unit 2 kg
Connections Heat circuit …
Heat source …
Refrigerant Refrigerant type ı Filling capacity … ı kg
Medium im Zwischenkreis Heizungswasser nach VDI 2035
Electrics Voltage code ı All-pole circuit breaker for pump *) … ı A
Voltage code ı Control voltage circuit breaker *) … ı A
Voltage code ı Electrical heating element circuit breaker *) ı A
Heat pump Effect. power consumption in the normal point W10/W55 as per EN14511: Power consumption ı Current consumption ı cosφ kW ı A ı …
Maximum machine current within the operating limits A
Starting current: direct ı with slow-starter A ı A
Protection type IP
Power of electrical heating element 3 ı 2 ı 1-phase kW ı kW ı kW
Components Circulating pump for heat circuit at nominal throughput: Power consumption ı Current consumption kW ı A
Circulating pump for heat source at nominal throughput: Power consumption ı Current consumption kW ı A
Setting range for motor protection switch of heat source circulating pump A
Passive cooling function Data only for devices with ID K: Cooling power at nominal volumetric flow rates (15 °C heat source, 25 °C hot water) kW
Safety devices Safety assembly for heat circuit ı Safety assembly for heat source in scope of supply: • yes — no
Heating and heat pump control in scope of supply: • yes — no
Electronic soft-starter integrated: • yes — no
Expansion vessels Heat source: Scope of supply ı Volume ı Supply pressure • yes — no ı l ı bar
Heat circuit: Scope of supply ı Volume ı Supply pressure • yes — no ı l ı bar
Overflow valve integrated: • yes — no
Vibration isolation Heat circuit ı Heat source in scope of supply: • yes — no
UK813198a *) Observe local regulations n.n. = cannot be demonstrated **) Flows according to standard nominal conditions
Technical data / scope of delivery
25Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
SWP561H— ı — ı •
• ı —•
- 73,7 ı 5,30
- 69,7 ı 3,50
20 - 70 7 - 25
4459
19400 ı 19400 ı 291000,38 ı 19400
———
— ı —6300 ı 12600 ı 15800
0,24 ı 12600— ı —
51
521——
DN50 DIN2566DN50 DIN2566R134a ı 12,8
•3~/PE/400V/50Hz ı C50
1~/N/PE/230V/50Hz ı B16— ı —
13,9 ı 28,2 ı 0,7145,6
310 ı 10520
— ı — ı —— ı —— ı —
——
— ı —••
— ı —— ı —
——
813449
SWP691— ı — ı •
• ı —•
- 92,8 ı 5,80
- 85,4 ı 3,70
20 - 65 7 - 25
4459
24700 ı 24700 ı 370000,33 ı 24700
———
— ı —8000 ı 16000 ı 20000
0,24 ı 16000— ı —
51
484——
DN50 DIN2566DN50 DIN2566R410A ı 13,4
•3~/PE/400V/50Hz ı C50
1~/N/PE/230V/50Hz ı B16— ı —
16,0 ı 28,6 ı 0,8148,5
272 ı 8520
— ı — ı —— ı —— ı —
——
— ı —••
— ı —— ı —
——
813447
SWP291H— ı — ı •
• ı —•
- 36,9 ı 5,30
- 33,2 ı 3,30
20 - 70 7 - 25
4358
10000 ı 10000 ı 150000,38 ı 10000
———
— ı —3200 ı 6400 ı 8000
0,22 ı 6400— ı —
51
319——
DN50 DIN2566DN50 DIN2566
R134a ı 6,7•
3~/PE/400V/50Hz ı C401~/N/PE/230V/50Hz ı B16
— ı —7,0 ı 15,2 ı 0,66
34174 ı 82
20— ı — ı —
— ı —— ı —
——
— ı —••
— ı —— ı —
——
813448
SWP581— ı — ı •
• ı —•
- 77,1 ı 6,10
- 71,4 ı 3,80
20 - 65 7 - 25
4257
19300 ı 19300 ı 289000,31 ı 19300
———
— ı —6600 ı 13200 ı 16500
0,22 ı 13200— ı —
51
441——
DN50 DIN2566DN50 DIN2566R410A ı 11,2
•3~/PE/400V/50Hz ı C50
1~/N/PE/230V/50Hz ı B16— ı —
12,6 ı 22,5 ı 0,8140
225 ı 8820
— ı — ı —— ı —— ı —
——
— ı —••
— ı —— ı —
——
813446
SWP451— ı — ı •
• ı —•
- 60,2 ı 6,10
- 54,9 ı 3,80
20 - 65 7 - 25
4156
15500 ı 15500 ı 232000,32 ı 15500
———
— ı —5200 ı 10400 ı 13000
0,21 ı 10400— ı —
51
385——
DN50 DIN2566DN50 DIN2566R410A ı 8,2
•3~/PE/400V/50Hz ı C40
1~/N/PE/230V/50Hz ı B16— ı —
9,8 ı 19,1 ı 0,7434
174 ı 3720
— ı — ı —— ı —— ı —
——
— ı —••
— ı —— ı —
——
813445
SWP371— ı — ı •
• ı —•
- 49,8 ı 6,0
- 44,6 ı 3,6
20 - 65 7 - 25
3954
12800 ı 12800 ı 192000,3 ı 12800
———
— ı —4300 ı 8600 ı 10800
0,22 ı 8600— ı —
51
371——
DN50 DIN2566DN50 DIN2566
R410A ı 7,2•
3~/PE/400V/50Hz ı C321~/N/PE/230V/50Hz ı B16
— ı —8,3 ı 14,4 ı 0,83
31140 ı 26
20— ı — ı —
— ı —— ı —
——
— ı —••
— ı —— ı —
——
813444
26 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbHBezeichnung:
Seite: 1/1
Zeichnungsnummer:
Datei: 823077 Leistungs-Druckverlustkurven SWP371.xls
Leistungs-DruckverlustkurvenSWP371
Legende: DE823025L
823077a
∆p„
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
a/PEP007-2011/Garthe/19.12.2011 823077a
Änd./Ä.M./Ersteller/Datum
-/PEP007-2011/Garthe/29.07.2011
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
20
30
40
50
60
70
80
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
65°C
1
2
3
4
5
6
7
8
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
COP
6
11
16
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5 10,0
“”[m3/h]
∆p (bar)
∆p”
0,0
0,1
0,2
0,3
0,0 5,0 10,0
“„[m3/h]
∆p (bar)
∆p„
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)
SWP 371 Performance curves – Brine operation
27Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Bezeichnung:
Seite: 1/1
Zeichnungsnummer:
Änd./Ä.M./Ersteller/Datum
-/PEP007-2011/Garthe/29.07.2011
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
∆p”
∆p„
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
a/PEP007-2011/Garthe/19.12.2011 823078aDatei: 823078 Leistungs-Druckverlustkurven SWP451.xls
Leistungs-DruckverlustkurvenSWP451
Legende: DE823025L
823078a
30
40
50
60
70
80
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
65°C
2
3
4
5
6
7
8
9
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
COP
8
13
18
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5 10,0 12,5
“”[m3/h]
∆p (bar)
∆p”
0,0
0,1
0,2
0,3
0,0 5,0 10,0 15,0
“„[m3/h]
∆p (bar)
∆p„
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)
Performance curves – Brine operation SWP 451
28 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbHBezeichnung:
Seite: 1/1
Zeichnungsnummer: a/PEP007-2011/Garthe/19.12.2011 823079a
Änd./Ä.M./Ersteller/Datum
-/PEP007-2011/Garthe/29.07.2011
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
Datei: 823079 Leistungs-Druckverlustkurven SWP581.xls
Leistungs-DruckverlustkurvenSWP581
Legende: DE823025L
823079a
∆p„
40
50
60
70
80
90
100
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
65°C
2
3
4
5
6
7
8
9
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
COP
10
15
20
25
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5 10,0 12,5 15,0
“”[m3/h]
∆p (bar)
∆p”
0,0
0,1
0,2
0,3
0,0 5,0 10,0 15,0 20,0
“„[m3/h]
∆p (bar)
∆p„
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)
SWP 581 Performance curves – Brine operation
29Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbHBezeichnung:
Seite: 1/1
Zeichnungsnummer: 823080a
Änd./Ä.M./Ersteller/Datum
-/PEP007-2011/Garthe/29.07.2011
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
a/PEP007-2011/Garthe/19.12.2011
Datei: 823080 Leistungs-Druckverlustkurven SWP691.xls
Leistungs-DruckverlustkurvenSWP691
Legende: DE823025L
823080a
∆p„
50
60
70
80
90
100
110
120
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
65°C
2
3
4
5
6
7
8
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
COP
10
15
20
25
30
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,0 2,5 5,0 7,5 10,0 12,5 15,0
“”[m3/h]
∆p (bar)
∆p”
0,0
0,1
0,2
0,0 5,0 10,0 15,0 20,0
“„[m3/h]
∆p (bar)
∆p„
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)
Performance curves – Brine operation SWP 691
30 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Bezeichnung:
Seite: 1/1
Zeichnungsnummer: a/ÄM067-2013/Garthe/18.09.2013 823081a
Änd./Ä.M./Ersteller/Datum
-/PEP018-2011/Garthe/09.05.2012
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
Datei: 823081a Leistungs-Druckverlustkurven SWP281H.xls
Leistungs-DruckverlustkurvenSWP291H
Legende: DE823025L
823081a
∆p„
20
30
40
50
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C 45°C
55°C 70°C
2
3
4
5
6
7
8
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
COP
5
10
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5
“”[m3/h]
∆p (bar)
Δp”
0,0
0,1
0,2
0,3
0,0 5,0 10,0
“„[m3/h]
∆p (bar)
Δp„
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)
SWP 291H Performance curves – Brine operation
31Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)
Bezeichnung:
Seite: 1/1
Zeichnungsnummer:
Datei: 823082 Leistungs-Druckverlustkurven SWP561.xls
Leistungs-DruckverlustkurvenSWP561H
Legende: DE823025L
823082
∆p„
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
823082
Änd./Ä.M./Ersteller/Datum
-/PEP018-2011/Garthe/09.05.2012
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
40
50
60
70
80
90
100
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
70°C
2
3
4
5
6
7
8
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
COP
11
16
21
26
-10 -5 0 5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5 10,0 12,5
“”[m3/h]
∆p (bar)
∆p…
0,0
0,1
0,2
0,3
0,4
0,0 5,0 10,0 15,0 20,0
“„[m3/h]
∆p (bar)
∆p…
Performance curves – Brine operation SWP 561H
32 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s) Bezeichnung:
Seite: 1/1
Zeichnungsnummer: a/ÄM067-2013/Garthe/18.09.2013 823077a
Änd./Ä.M./Ersteller/Datum
-/PEP???-2013/Garthe/14.02.2013
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
Datei: 823077a Leistungs-Druckverlustkurven SWP371.xls
Leistungs-DruckverlustkurvenSWP371
Legende: DE823025L
823077a
∆p„
35
45
55
65
5 10 15 20 25
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
65°C
1
2
3
4
5
6
7
8
5 10 15 20 25
Temp„ (°C)
COP
6
11
16
5 10 15 20 25
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5 10,0
“”[m3/h]
∆p (bar)
Δp”
0,0
0,1
0,2
0,3
0,0 5,0 10,0
“„[m3/h]
∆p (bar)
Δp„
SWP 371 Performance curves – Water operation
33Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)Bezeichnung:
Seite: 1/1
Zeichnungsnummer:
Änd./Ä.M./Ersteller/Datum
-/PEP007-2011/Garthe/29.07.2011
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
∆p”
∆p„
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
a/ÄM067-2013/Garthe/18.09.2013 823078aDatei: 823078a Leistungs-Druckverlustkurven SWP451.xls
Leistungs-DruckverlustkurvenSWP451
Legende: DE823025L
823078a
45
55
65
75
5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
65°C
2
3
4
5
6
7
8
5 10 15 20 25 30
Temp„ (°C)
COP
8
13
18
5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5 10,0 12,5
“”[m3/h]
∆p (bar)
Δp”
0,0
0,1
0,2
0,3
0,0 5,0 10,0 15,0
“„[m3/h]
∆p (bar)
Δp„
Performance curves – Water operation SWP 451
34 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s) Bezeichnung:
Seite: 1/1
Zeichnungsnummer:
Datei: 823079a Leistungs-Druckverlustkurven SWP581.xls
Leistungs-DruckverlustkurvenSWP581
Legende: DE823025L
823079a
∆p„
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
a/ÄM067-2013/Garthe/18.09.2013 823079a
Änd./Ä.M./Ersteller/Datum
-/PEP007-2011/Garthe/29.07.2011
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
60
70
80
90
100
5 10 15 20 25
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
65°C
2
3
4
5
6
7
8
9
5 10 15 20 25
Temp„ (°C)
COP
10
15
20
25
5 10 15 20 25
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5 10,0 12,5 15,0
“”[m3/h]
∆p (bar)
Δp”
0,0
0,1
0,2
0,3
0,0 5,0 10,0 15,0 20,0
“„[m3/h]
∆p (bar)
Δp„
SWP 581 Performance curves – Water operation
35Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)Bezeichnung:
Seite: 1/1
Zeichnungsnummer: a/ÄM067-2013/Garthe/18.09.2013
Datei: 823080a Leistungs-Druckverlustkurven SWP691.xls
Leistungs-DruckverlustkurvenSWP691
Legende: DE823025L
823080a
∆p„
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
823080a
Änd./Ä.M./Ersteller/Datum
-/PEP007-2011/Garthe/29.07.2011
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
∆p”
70
80
90
100
110
120
5 10 15 20 25
Temp„ (°C)
Qh (kW)
35°C
45°C
55°C
65°C
2
3
4
5
6
7
8
5 10 15 20 25
Temp„ (°C)
COP
15
20
25
30
5 10 15 20 25
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,0 2,5 5,0 7,5 10,0 12,5 15,0
“”[m3/h]
∆p (bar)
Δp”
0,0
0,1
0,2
0,0 5,0 10,0 15,0 20,0
“„[m3/h]
∆p (bar)
Δp„
Performance curves – Water operation SWP 691
36 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s) Bezeichnung:
Seite: 1/1
Zeichnungsnummer:
Datei: 823081 Leistungs-Druckverlustkurven SWP291H.xls
Leistungs-DruckverlustkurvenSWP291H
Legende: DE823025L
823081
∆p„
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
823081
Änd./Ä.M./Ersteller/Datum
-/ÄM067-2013/Garthe/18.09.2013
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
30
40
50
5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C 45°C
55°C 70°C
2
3
4
5
6
7
8
5 10 15 20 25 30
Temp„ (°C)
COP
6
11
5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5
“”[m3/h]
∆p (bar)
Δp”
0,00,10,20,30,40,50,60,70,80,9
0,0 5,0 10,0 15,0
“„[m3/h]
∆p (bar)
Δp„
SWP 291H Performance curves – Water operation
37Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Legend: UK823025L
“” Volume flow, heating water
“„ Volume flow, heat source
Temp„ Temperature, heat source
Qh Heating capacity
Pe Power consumption
COP Coefficient of performance / efficiency rating
∆p” Pressure loss heat circuit
∆p„ Pressure loss heat source
VD Compressor(s)Bezeichnung:
Seite: 1/1
Zeichnungsnummer:
Datei: 823082 Leistungs-Druckverlustkurven SWP561H.xls
Leistungs-DruckverlustkurvenSWP561H
Legende: DE823025L
823082
∆p„
∆p”
“”
Druckverlust Heizkreis
Volumenstrom Heizwasser
Volumenstrom Wärmequelle
Temperatur Wärmequelle
Heizleistung
Leistungsaufnahme
Coeffiicient of performance / Leistungszahl
823082
Änd./Ä.M./Ersteller/Datum
-/ÄM067-2013/Garthe/18.09.2013
Druckverlust Wärmequelle
“„
Temp„
Qh
Pe
COP
60
70
80
90
100
5 10 15 20 25 30
Temp„ (°C)
Qh (kW)
35°C 45°C
55°C 70°C
2
3
4
5
6
7
8
5 10 15 20 25 30
Temp„ (°C)
COP
11
16
21
26
5 10 15 20 25 30
Temp„ (°C)
Pe (kW)
0,0
0,1
0,2
0,3
0,0 2,5 5,0 7,5 10,0 12,5
“”[m3/h]
∆p (bar)
Δp”
0,0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,0 5,0 10,0 15,0 20,0 25,0
“„[m3/h]
∆p (bar)
Δp„
Performance curves – Water operation SWP 561H
38 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
D
0131
1219
1340
1350
10
0
123
781902912
E
0,18N/mm²
0,32N/mm²
0,005N/mm²
0
1190 51
1139
0100170
961A
87
051709
760
B
0
237
756
0
198
1084
C
Legende: DE819407
A VorderansichtB Seitenansicht von linksC RückansichtD Vorderansicht mit Fassade E Ansicht von unten mit Fassade
87654321
www.alpha-innotec.deD - 95359 Kasendorf
Industriestraße 3Alpha-InnoTec GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
BenennungMaßbild SWP Redesign
Einbringmaße, Belastungsangaben
819407 -Zust. Änderungstext
PEP 007/2011
Datum27.9.2011
REVon
Blatt
von
Werkstoff Gewicht
Maßstab 1:20 Det. Maßstab
Datum NameErstelltGepr.Norm.
16.9.2011 Eberlein
toleranzAllgemein-
DIN ISO 2768 -c
Oberflächen
ArtikelNr.Alle Maße in mm. Toutes les mesures en mm. All measures in mm.Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Subject to technical modifications.
Schu
tzverm
erk IS
O 16
016 b
each
ten
Legend: EN819407All dimensions in mm.
A Front viewB Side view from leftC Rear viewD Front view with facing E View from underneath with facing
SWP 371 – SWP 691 Dimensional drawings - moving dimensions
39Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
0
1030
990
010
1340
1350
A
097 912
902
B
0
135
756
190
081266
485
580
1152
237
3
7
65
4
E
2
0
275
0
159
G1
H0 47 70
165
4x 18
12589
Legende : DE819406aAlle Maße in mm
A VorderansichtB Seitenansicht von linksE RückansichtG Vorderansicht BedienteilH Seitenansicht von links BedienteilI Anschlussmöglichkeiten
I
Pos. Bezeichnung1 Bedienteil (für Wandmontage, im Beipack)2 Durchführung für Verbindungs- und LIN-Bus-Kabel3 Durchführung für Elektrokabel4 Wärmequelle Austritt (aus Wärmepumpe)5 Wärmequelle Eintritt (in Wärmepumpe)6 Heizwasser Austritt (Vorlauf)7 Heizwasser Eintritt (Rücklauf)8 Flansch DN50 PN10/16 9 R2" Aussengewinde
87654321
www.alpha-innotec.deD - 95359 Kasendorf
Industriestraße 3Alpha-InnoTec GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
BenennungMaßbildSWP Redesign AIT
819406 a-Zust. Änderungstext
PEP 007/2011
ÄM 054/2013
Datum10.5.201223.10.2013
DMVon
RA Blatt
von
Werkstoff Gewicht
Maßstab 1:20 1:15Det. Maßstab
Datum NameErstelltGepr.Norm.
15.9.2011 Eberlein23.10.2013 Aepfelbach
toleranzAllgemein-
DIN ISO 2768 -c
Oberflächen
ArtikelNr.Alle Maße in mm. Toutes les mesures en mm. All measures in mm.Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Subject to technical modifications.
Schu
tzverm
erk IS
O 16
016 b
each
ten
Legend: EN819406a Item Designation1 Control element (for wall mounting, in extra box)
A Front view” 2 Penetration for connection and LIN bus cableB Side view from lef 3 Penetration for electric cableE Rear view 4 Heat source outlet (from heat pump)G Front view, control 5 Heat source inlet (in heat pump)H Side view from left, control 6 Heating water outlet (flow)I Connection options 7 Heating water inlet (return)
8 Flange DN50 PN10/16 9 male thread
Dimensional drawings with housing SWP 371 – SWP 691
40 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
D
0131
1219
1340
1350
10
0
123
781902912
E
0,18N/mm²
0,32N/mm²
0,005N/mm²
0
237
756
0
226
686
0
1110 19
8
C 051
1139
1190
0
170100
961A
87
051709
760
B
Legende: DE819416
A VorderansichtB Seitenansicht von linksC RückansichtD Vorderansicht mit Fassade E Ansicht von unten mit Fassade
87654321
www.alpha-innotec.deD - 95359 Kasendorf
Industriestraße 3Alpha-InnoTec GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
Benennung
819416 -Zust. Änderungstext
PEP 018/2011
Datum11.5.2012
DMVon
Blatt
von
Werkstoff Gewicht
Maßstab 1:20 Det. Maßstab
Datum NameErstelltGepr.Norm.
11.5.2012 Kleuderlein11.5.2012 Markieton
toleranzAllgemein-
DIN ISO 2768 -c
Oberflächen
ArtikelNr.Alle Maße in mm. Toutes les mesures en mm. All measures in mm.Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Subject to technical modifications.
Schu
tzverm
erk IS
O 16
016 b
each
ten
Maßbild SWP-H RedesignEinbringmaße, Belastungsangaben
Legend: UK819416All dimensions in mm.
A Front viewB Side view from leftC Rear viewD Front view with facing E View from underneath with
facing
SWP 291H – SWP 561H Dimensional drawings - moving dimensions
41Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
0
1030
990
010
1340
1350
A
097 912
902
B
0
135
756
190
081266
485
580
1178
237
0
226
686
3
6E
2
7
4
5
0
275
0
159
G1
0 47 70
H
165
4x 18
12589
Legende : DE819414aAlle Maße in mm
A VorderansichtB Seitenansicht von linksE RückansichtG Vorderansicht BedienteilH Seitenansicht von links BedienteilI Anschlussmöglichkeiten
I
Pos. Bezeichnung1 Bedienteil (für Wandmontage, im Beipack)2 Durchführung für Verbindungs- und LIN-Bus-Kabel3 Durchführung für Elektrokabel4 Wärmequelle Austritt (aus Wärmepumpe)5 Wärmequelle Eintritt (in Wärmepumpe)6 Heizwasser Austritt (Vorlauf)7 Heizwasser Eintritt (Rücklauf)8 Flansch DN50 PN10/16 9 R2" Aussengewinde
87654321
www.alpha-innotec.deD - 95359 Kasendorf
Industriestraße 3Alpha-InnoTec GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
BenennungMaßbildSWP-H Redesign AIT
819414 a-Zust. Änderungstext
PEP 018/2011
ÄM 054/2013
Datum10.5.201223.10.2013
DMVon
RA Blatt
von
Werkstoff Gewicht
Maßstab 1:20 1:15Det. Maßstab
Datum NameErstelltGepr.Norm.
10.5.2012 Kleuderlein23.10.2013 Aepfelbach
toleranzAllgemein-
DIN ISO 2768 -c
Oberflächen
ArtikelNr.Alle Maße in mm. Toutes les mesures en mm. All measures in mm.Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Subject to technical modifications.
Schu
tzverm
erk IS
O 16
016 b
each
ten
Legend: EN819414a Item Designation1 Control element (for wall mounting, in extra box)
A Front view” 2 Penetration for connection and LIN bus cableB Side view from lef 3 Penetration for electric cableE Rear view 4 Heat source outlet (from heat pump)G Front view, control 5 Heat source inlet (in heat pump)H Side view from left, control 6 Heating water outlet (flow)I Connection options 7 Heating water inlet (return)
8 Flange DN50 PN10/16 9 male thread
Dimensional drawings with housing SWP 291H – SWP 561H
42 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
1030 >1
600
A1
2
max. 13m
>800
912
>900
>500 >500
1350
B
1
Legende : DE819408
A VorderansichtB Draufsicht1 Schraffierte Fläche Freiraum für Servicezwecke2 Bedienteil
87654321
www.alpha-innotec.deD - 95359 Kasendorf
Industriestraße 3Alpha-InnoTec GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
BenennungAufstellungsplanSWP Redesign
819408 -Zust. Änderungstext
PEP 007/2011
Datum28.9.2011
REVon
Blatt
von
Werkstoff Gewicht
Maßstab 1:50 Det. Maßstab
Datum NameErstelltGepr.Norm.
15.9.2011 Eberlein
toleranzAllgemein-
DIN ISO 2768 -c
Oberflächen
ArtikelNr.Alle Maße in mm. Toutes les mesures en mm. All measures in mm.Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Subject to technical modifications.
Schu
tzverm
erk IS
O 16
016 b
each
ten
Legend: EN819408
A Front viewB Plan view1 Hatched area = space for service purposes2 Control element
SWP 371 – 691 / SWP 291H – 561H Installation plan 1
43Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
>160
010
30
A1
2
>800
912
>900
>2730>30
>500>500
B
1
Legende : DE819409
A VorderansichtB Draufsicht1 Schraffierte Fläche Freiraum für Servicezwecke2 Bedienteil
max.13m
87654321
www.alpha-innotec.deD - 95359 Kasendorf
Industriestraße 3Alpha-InnoTec GmbH
1
1
Ers. d. Ers. f.
A
B
C
D
E
F F
E
D
C
B
A
4321
BenennungAufstellungsplan
SWP Redesign Kaskadenaufstellung
819409 -Zust. Änderungstext
PEP 007/2011
Datum28.9.2011
REVon
Blatt
von
Werkstoff Gewicht
Maßstab 1:50 Det. Maßstab
Datum NameErstelltGepr.Norm.
15.9.2011 Eberlein
toleranzAllgemein-
DIN ISO 2768 -c
Oberflächen
ArtikelNr.Alle Maße in mm. Toutes les mesures en mm. All measures in mm.Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Subject to technical modifications.
Schu
tzverm
erk IS
O 16
016 b
each
ten
Legend: EN819409
A Front viewB Plan view1 Hatched area = space for service purposes2 Control element
Installation plan 2 SWP 371 – 691 / SWP 291H – 561H
44 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
SWP 371 – 691 / SWP 291H – 561H Separate buffer tank
45Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Lege
nd h
ydra
ulic
dia
gram
m14
0304
1H
eat p
ump
51S
eper
atio
n ta
nkTA
/AE
xter
nal s
enso
r2
Und
erflo
or h
eatin
g / r
adia
tors
52G
as- o
r oil-
boile
rTB
W/B
Dom
estic
hot
wat
er s
enso
r3
Vib
ratio
n is
olat
ion
53W
ood
boile
rTB
1/C
Feed
wat
er s
enso
r mix
er c
ircui
ts 1
4S
ylom
er s
trip
mac
hine
und
erla
y54
Hot
wat
er c
ylin
der
DFl
oor t
mpe
ratu
re li
mite
r5
Clo
sure
and
dra
inag
e55
Brin
e pr
essu
re s
witc
hTR
L/G
Sen
sor e
xter
nal r
etur
n6
Exp
ansi
on v
esse
l pac
king
list
56S
wim
min
g po
ol h
eat e
xcha
nger
STA
Line
pre
ssur
e re
gula
tor v
alve
7S
afet
y va
lve
57G
eoth
erm
al h
eat e
xcha
nger
TRL/
HS
enso
r ret
urn
(hyd
raul
ic m
odul
e, d
ual)
8C
losu
re
58V
entil
atio
n sy
stem
9H
eatin
g ci
rcul
atio
n pu
mp
59P
late
hea
t exc
hang
er79
Mot
or v
alve
10N
on re
turn
val
ve/ o
ne w
ay v
alve
61C
oolin
g cy
linde
r80
Mix
ing
valv
e11
Indi
vidu
al ro
om re
gula
tion
65C
ompa
ct d
istri
buto
r81
Spl
it he
at p
ump
outd
oor u
nit
12O
verfl
ow v
alve
66Fa
ncoi
ls82
Spl
it he
at p
ump
indo
or u
nit
13S
team
tight
insu
latio
n67
Sol
ar/ s
ervi
ce w
ater
cyl
inde
r83
Circ
ulat
ion
pum
p14
Ser
vice
wat
er c
ircul
atio
n pu
mp
68S
olar
/ ser
vice
wat
er c
ylin
der
84S
witc
hing
val
ve15
Mix
er c
ircui
t thr
ee-w
ay m
ixer
(MK
1 di
scha
rge)
69M
ultif
unct
ion
tank
113
Con
nect
ion
2nd
heat
gen
erat
or
16
Exp
ansi
on v
esse
l sup
plie
d by
cus
tom
er71
Dua
l hyd
raul
ic m
odul
eB
T1O
utdo
or te
mpe
ratu
re s
enso
r18
Hea
ting
rod
(hea
ting)
72B
uffe
r tan
k w
all m
ount
edB
T2Fl
ow te
mpe
ratu
re s
enso
r 19
Mix
er c
ircui
t fou
r-w
ay m
ixer
(MK
1 ch
arge
)73
Pip
e le
ad-in
BT3
Ret
urn
tem
pera
ture
sen
sor
20H
eatin
g ro
d (S
W)
74V
ento
wer
BT6
Dom
estic
hot
wat
er te
mpe
ratu
re s
enso
r21
Mix
er c
ircui
t circ
ulat
ion
pum
p (F
P1)
75S
cope
of d
eliv
ery,
hyd
raul
ic to
wer
, dua
lB
T12
Flow
tem
pera
ture
liqu
efie
r23
Feed
circ
ulat
ing
pum
p (r
econ
nect
the
inte
grat
ed c
ircul
atin
g pu
mp
in th
e he
at p
ump)
76Fr
esh
wat
er s
tatio
nB
T19
Tem
pera
ture
sen
sor i
mm
ersi
on h
eate
r
24M
anifu
ld77
Sco
pe o
f sup
ply
wat
er/w
ater
boo
ster
BT2
4Te
mpe
ratu
re s
enso
r 2nd
hea
t gen
erat
or25
Hea
ting
circ
ulat
ion
pum
p78
Acc
esso
ries
wat
er/w
ater
boo
ster
opt
iona
l26
Sw
itchi
ng v
alve
(hea
ting/
serv
ice
wat
er)(
B =
norm
ally
ope
n)27
Hea
ting
elem
ent
28B
rine
circ
ulat
ion
pum
pC
omfo
rt bo
ard:
29D
irt-tr
ap 0
.6 m
m m
esh
15M
ixer
circ
uit t
hree
-way
mix
er (M
K2-
3 di
scha
rge)
30S
pill-
tray
für b
rine
mix
100
Roo
m th
erm
osta
t for
coo
ling
(opt
iona
l)17
Tem
pera
ture
diff
eren
ce re
gula
tor
31W
all b
reak
thro
ugh
101
Con
trols
sup
plie
d by
cus
tom
er19
Mix
er c
ircui
t fou
r-w
ay m
ixer
(MK
2 ch
arge
)32
Inle
t pip
e10
2D
ew-p
oint
mon
itor (
optio
nal)
21M
ixer
circ
uit c
ircul
atio
n pu
mp
(FP
2-3)
33B
rine
man
ifuld
103
Roo
m th
erm
osta
t for
refe
renc
e sp
ace
in p
acki
ng li
st22
Sw
imm
ing
pool
circ
ulat
ing
pum
p34
Gro
und
colle
ctor
104
Sup
ply
heat
pum
p44
Thre
e-w
ay m
ixer
val
ve (c
oolin
g fu
nctio
n M
K2)
35G
roun
d sl
inki
es10
5C
oolin
g ci
rcui
t mod
ule
box
rem
ovea
ble
for i
nsta
llatio
n47
C
hang
eove
r val
ve s
wim
min
g ba
th p
repa
ratio
n(B
= no
rmal
ly o
pen)
36G
roun
dwat
er s
prin
g pu
mp
106
Spe
cific
gly
cole
mix
ture
60C
hang
eove
r val
ve c
oolin
g op
erat
ion(
B =
norm
ally
ope
n)37
Wal
l bra
cket
107
Sca
ld p
rote
ctio
n / t
herm
osta
tic m
ixer
val
ve62
Hea
t met
er (o
ptio
nal)
38Fl
ow s
witc
h10
8S
olar
pum
p as
sem
bly
63C
hang
eove
r val
ve s
olar
circ
uit(B
= n
orm
ally
ope
n)39
Suc
tion
wel
l10
9O
verfl
ow v
alve
mus
t be
clos
ed64
Coo
ling
circ
ulat
ion
pum
p40
Inve
rted
wel
l11
0P
acki
ng li
st h
ydra
ulic
tow
er70
Sol
ar s
eper
atio
n m
odul
e41
Rin
se fi
tting
hea
ting
circ
uit
111
Mou
ntin
g fo
r add
ition
al h
eatin
g el
emen
tTB
2-3/
CFe
edw
ater
sen
sor m
ixer
circ
uits
2-3
42C
ircul
atio
n pu
mp
112
Min
imum
dis
tanc
e to
ther
mal
dec
oupl
ing
of th
e m
ixin
g va
lve
TSS
/ES
enso
r, te
mpe
ratu
re d
iffer
ence
con
trol (
low
tem
pera
ture
)43
Brin
e / W
ater
hea
t exc
hang
er (c
oolin
g fu
nctio
n)TS
K/E
Sen
sor,
tem
pera
ture
diff
eren
ce c
ontro
l (hi
gh te
mpe
ratu
re)
44Th
ree-
way
mix
er v
alve
(coo
ling
func
tion
MK
1)TE
E/F
Sen
sor e
xter
nal e
nerg
y so
urce
45C
ap v
alve
46Fi
ller a
nd d
rain
age
valv
e48
Dom
estic
hot
wat
er c
harg
ing
pum
p49
Dire
ctio
n of
gro
undw
ater
flow
50B
uffe
r sto
rage
Impo
rtant
not
ice
!
Thes
e hy
drau
lic d
iagr
ams
are
sche
mat
ic re
pres
enta
tions
and
are
for a
ssis
tanc
e on
ly. T
hey
do n
ot re
lieve
of t
he o
blig
atio
n to
car
ry o
ut a
ppro
pria
te p
lann
ing!
The
y do
not
incl
ude
all n
eces
sary
shu
t-off
valv
es, v
entil
ator
fit
tings
or s
afet
y de
vice
s. T
hese
mus
t be
inco
rpor
ated
in a
ccor
danc
e w
ith th
e st
anda
rds
and
regu
latio
ns a
pplic
able
to th
e re
spec
tive
inst
alla
tion.
All
coun
try-s
peci
fic s
tand
ards
, law
s an
d re
gula
tions
mus
t be
obse
rved
! The
tu
bes
have
to b
e di
men
sion
ed a
ccor
ding
to th
e no
min
al v
olum
e flo
w o
f the
hea
t pum
p re
sp. t
he fr
ee p
ress
ing
of th
e in
tegr
ated
circ
ulat
ing
pum
p. F
or d
etai
led
info
rmat
ion
and
advi
ce p
leas
e co
ntac
t our
loca
l sal
es p
artn
er!
46 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
12
-F11
34
56
-F1
2
A1
A2
FP
1
EV
U
FP1
Sub-distribution unit intern
al installation
ASD
PE
X
TA
L1
Pum
p for mixing circuit 1
Leg
en
d:
MA
1/MIS
HU
P
Charge/discharge/cooling m
ixer 1 close
d
EV
U
X0-X
4
Hot w
ater gauge/therm
ostat
Heating circuit circulating pum
p
TBW
Accessories: R
emote control
TRL
VBO
PEX
ZW1
GND
Q0:L
1,L2,L3,PE
Controller board; A
ttention: I-max =
6A
/230VA
C
3
TB
1
External return sensor
GND
MOT
Hot w
ater circulating pum
p/switching valve
TR
L
ZUP
ZW
1
3~PE/400V/50Hz
Term
inal strips on controller board
Function
Q0
Term
inals in heat pum
p switchbox
External flo
w ra
te switch; bridge if no sw
itch is connecte
d.
N
Main
contactor; m
ains power 3~
PE
/400V/50H
z
M
RF
V
X10
Q0
BU
P
RFV
2
F11
L1
GND
Energy supplier contact; close
d on release; bridge if no blocking inte
rval
A5
TA
-X3
N
MIS
MZ1
GND
-X2
EVU
Control signal of add
itional heat generator 1
MO
T
ZIP
X10:L,N
,PE
N
TBW
N
X10
1~N/PE/230V/50Hz
TB1
Sensor m
ixing circuit 1
PE
ZU
P
4
SW
P
VB
O
A1
F12
A5
Cut out controller unit
A2
A1
connection
control unit
L
-X
LIN
Nam
e
External sensor
ZW
2/SS
T
ZW2/SST
TA
Single pole m
iniature circuit-breaker of compressor to IE
C 60947-2; Im
portant: Clockw
ise rotary field is absolutely essential!
L1
Auxiliary circulation pum
p
L2
No function
Control signal of add
itional heat generator 2 (alternative is general m
alfunction)HUP
PE
-X1
0
DF
S
PE
Brine pum
p
TB1
PE
PE
MA1
HU
P
Pow
er supply controller 230V ZU
P
Term
inal strip in sw
itchbox of heat pum
p; N/P
E distribu
tion for external 230V units
TB
W
UK
83
1175
N
Connection of external m
otor protection; bridge if no external m
otor protection is connected.
PE
FP
1
L1
DF
S
ZIP
Control e
lement
RFV
ZW
2
Pow
er supply compressor; 3x400V
; Importa
nt: Clockw
ise rotary field is absolutely necessary!
-X4
Term
inals
GND
MZ
1/MIS
VB
O
A2
MO
T
TRL
Charge/discharge/cooling m
ixer 1 open
3
2
-X0
LIN
ZW
1
Information
on fuses can be found in the technical data
GND
L3
BU
P
circulation pump
ZIP
X10
BUP
1
Term
inal diagram S
WP
generation 2011831175
Achim
Pfleg
er3
0.05.2
011
-P
EP
007/2011
12
34
56
78
910
1112
1314
1516
12
34
56
78
910
1112
1314
1516 1
/1
1
30.0
9.2
011
Achim
Pfleg
er
Blatt-N
r.
Zusta
ndÄ
nde
rung
Bea
rb.
Datu
mN
ame
Bl vo
n An
z
Datu
m
SWP 371 – 691 / SWP 291H – 561H Terminal diagram
47Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
PE
IN0V
L1UL2VL3W
-Q11
1412
11
-K1
/2.4
12
-Q0
/2.5
34
56P
E
-X1
0
M3
T1
T2
T3
PE
-M1
VD
1-E
20
E20
/2.1N
/2.1
2
Q0
Ma
ins conta
ctor, com
pressor
VD
1
Q11
Leg
en
d:
PE
UK
8173
79a
3~P
E/40
0V/50H
z
E20
-M1
Operating
materials
VD
1com
pre
ssor
Sta
rting cu
rrent limit co
mpressor
K1
M1
1
L1,L2,L
3,PE
; pow
er su
pply, o
utput, com
pressor; clo
ckwise ro
tary fie
ld is absolute
ly necessary!
L3
L2
L1
3
Fun
ction
Sum
p heatin
g for compre
ssor 1
3~P
E/400V
/50Hz
auxiliary rela
y com
pressor
X10
Term
inal in sw
itch box h
eat p
ump
27.01.2014
PE
P 007
/2011
1
Achim
Pfleg
er
10X
614 - 10X
615;
-
1/3
Achim
Pfleg
er1
7.05.2011
SW
P 371; S
WP
451817379
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
aÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
Circuit diagram 1/3 SWP 371 / SWP 451
48 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
E20
/1.15
N/1.15,1
5
PE
-X1PE
-X1
0
NN
LL
P+
-
b2c4a1
-F1
HD
P
DI1
-X2
DI2
OUT1
A1
A2
-K1
OUT4
OUT5
A1
A2
-Q0
L..
-X4
L..
L..
B/
-X6
A
Green
Yellow
white
Brown
-K2
2 A/
B
ϑ
NT1
-X7
-R1
TS
G1
GND
ϑ
NT2
-R2
TV
D
GND
ϑ
NT3
-R3
TW
E
GND
ϑ
NT4
-R4
TH
G
GND
ϑ
NT5
-R5
TS
G2
GND
ϑ
NT6
-R6
TV
L
GND
ϑ
NT7
-R7
TR
L
GND
ϑ
NT8
-R8
TW
A
GND
NT9
-R9
CW
GND
GND
-X8
IP
12
-B1
0H
D
AIN1
GND
IP
12
-B1
1N
D
AIN2
L/3.1
N1,/3.1
PE
/3.1
3 -X1
12
32
1P
E
1
12
/1.53
4/1.5
56
/1.5
1214
11/1.3
UK
8173
79a
TW
E
Q0
2
TS
G1
R2
Hig
h-pressure sw
itch
TR
L
TS
G2
R8
B10
HD
Co
ntroller board; A
ttentio
n: I-ma
x = 6A
/230VA
CV
D1
3
auxilia
ry relay co
mpressor
Ho
t gas senso
r
230
VA
C
R1
Co
der resistance
; 11,0 kO
hm
-F1
K1
Sum
p h
eating sen
sor
GN
D/LIN
/12V
Leg
en
d:
R4
1~N
/PE
/230V/50H
z
K22
HD
P
R9
K20
F1
r t
Hig
h-pressure sen
sor
-K201~
N/P
E/230V
/50Hz
TH
G
1
TV
L
sw
2
He
at source inpu
t sensor
Suction sensor, com
pressor
1
TV
D
41
23
CW
TW
A
R5
Term
inal in sw
itch box h
eat pum
pX
10
Fun
ctionL,N
,PE
; pow
er supply, contro
ller
R3
Electron
ic expansion valve
ND
He
at source outpu
t sensor
Low
pressure
sensor
Suction sensor, e
vapo
rator
R7
Ma
ins contactor, com
pressor
Operating
materials
blB
11
Flo
w se
nsorR
etu
rn sensor
2
R6
1
27.01.2014
PE
P 007
/2011
2
Achim
Pfleg
er
10X
614 - 10X
615;
-
2/3
Achim
Pfleg
er2
7.09.2010
SW
P 371; S
WP
451817379
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
aÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
SWP 371 / SWP 451 Circuit diagram 2/3
49Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
L/2.15
N/2.15
PE
/2.15
L-X
0N
PE
L-X
0L
L
MOT
-X2
.
ASD
EVU
K10
MO
TC
onnection o
f external motor p
rotection; bridge
if no e
xtern
al moto
r prote
ction is connected.
UK
8173
79
a
Controller board; A
ttentio
n: I-ma
x = 6A
/230V
AC
AS
DF
unction
EV
U
Exte
rnal flo
w rate sw
itch; bridge if no sw
itch is co
nnected.
Leg
en
d:
-K10
MO
T
Operating
materials
AS
D
Energy supp
lier conta
ct; closed on relea
se; bridge if no blo
cking interva
lE
VU
27.01.2014
PE
P 007
/2011
3
Achim
Pfleg
er
10X
614 - 10X
615;
-
3/3
Achim
Pfleg
er2
3.05.2011
SW
P 371; S
WP
451817379
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
aÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
Circuit diagram 3/3 SWP 371 / SWP 451
50 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
PE
IN0V
L1UL2VL3W
-Q11
1412
11 -K1
/2.4
12
-Q0
/2.5
34
56P
E
-X1
0
M3
T1
T2
T3
PE
-M1
VD
1
T1
-230
V
T2
M1
-F1.1 M
2
L Reg
/2.1N
/2.1
HD
P/2.1
MO
T/2.1
L3
L2
L1
F1.1
Com
pressor mo
tor prote
ction
42
PE
Leg
en
d:
UK
8173
80a
Q11
2
Sta
rting curre
nt limit co
mpressor
Q0
VD
1
-M1
comp
resso
r
Ma
ins conta
ctor, com
pressor
3~P
E/400V
/50Hz
K1
M1
Fun
ction
Sum
p heatin
g for compre
ssor 1
13
Term
inal in sw
itch box h
eat p
ump
3
L1,L2,L
3,PE
; pow
er su
pply, o
utput, com
pressor; clo
ckwise ro
tary fie
ld is absolute
ly necessary!
Operating
materials
3~P
E/40
0V/50H
z
1
X10
VD
1au
xiliary relay co
mpressor
E20
27.01.2014
PE
P 007
/2011
1
Achim
Pfleg
er
10X
616; 10X
617;
10X
619;
-
1/3
Achim
Pfleg
er1
7.05.2011
SW
P 581 - 691; 561H
817380
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
aÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
SWP 581 / SWP 691 / SWP 561H Circuit diagram 1/3
51Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
L Reg
/1.15
MO
T/1.15
HD
P/1.15
N/1.15,1
5
PE
-X1PE
-X1
0
NN
LL
P+
-
b2c4a1
-F1
HD
P
DI1
-X2
DI2
1314
-Q05
1
-X1
0
OUT1
A1
A2
-K1
OUT5
A1
A2
-Q0
L..
-X4
L..
L..
B/
-X6
A
Green
Yellow
white
Brown-K
22
A/
B
ϑ
NT1
-X7
-R1
TS
G1
GND
ϑ
NT3
-R3
TW
E
GND
ϑ
NT4
-R4
TH
G
GND
ϑ
NT5
-R5
TS
G2
GND
ϑ
NT6
-R6
TV
L
GND
ϑ
NT7
-R7
TR
L
GND
ϑ
NT8
-R8
TW
A
GND
NT9
-R9
CW
GND
GND
-X8I
P
12
-B1
0H
D
AIN1
GND
IP
12
-B1
1N
D
AIN2
L/3.1
N1,/3.1
PE
/3.1
3 -X1
12
32
1P
E
1
12
/1.43
4/1.4
56
/1.413
144
1214
11/1.2
43
21
1
TW
A
TV
L
Term
inal in sw
itch box h
eat pum
p
-K20
2
X10
2
K20
Ho
t gas senso
r
1
Fun
ction
TH
G
HDTR
L
auxiliary rela
y compressor
Ma
ins contacto
r, com
pressor
GN
D/LIN
/12V
Hig
h-pressure sen
sor
R6
TS
G2
R4
K1
F1
1~N
/PE
/230V/50H
z
Hig
h-pressure sw
itch
R2
Electron
ic expansio
n valve
2
1~N
/PE
/230V
/50Hz
VD
1
3
TS
G1 2
30
VA
C
rt
-F1
Suction sensor, e
vapo
rator
Co
ntroller board; A
ttention: I-m
ax = 6A
/230V
AC
Suction sensor, com
pressor
B10
Leg
en
d:
1
Low
pressure
sensor
R9
CW
Co
der resistance
; S58
-69K
W 11
,5kOh
m / S
29-56
KW
12,1kO
hm
TV
DS
ump h
eating sen
sorT
WE
Flo
w se
nsorR
5
K22
Re
turn sensor
B11
R7
R1
HD
P
Q0
Operating
materials
R3
He
at source outpu
t sensor
R8
sw
UK
8173
80a
ND
L,N,P
E; p
owe
r supply, contro
ller
He
at source inpu
t sensor
bl
27.01.2014
PE
P 007
/2011
2
Achim
Pfleg
er
10X
616; 10X
617;
10X
619;
-
2/3
Achim
Pfleg
er2
7.09.2010
SW
P 581 - 691; 561H
817380
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
aÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
Circuit diagram 2/3 SWP 581 / SWP 691 / SWP 561H
52 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
L/2.15
N/2.15
PE
/2.15
L-X
0N
PE
L-X
0L
L
MOT
-X2
.
ASD
EVU
-K10
MO
T
Exte
rnal flo
w rate sw
itch; bridge if no sw
itch is co
nnected.
Leg
en
d:
Energy supp
lier conta
ct; closed on relea
se; bridge if no blo
cking interva
lE
VU
Operating
materials
AS
D
K10
Controller board; A
ttentio
n: I-ma
x = 6A
/230V
AC
MO
T
UK
8173
80
a
EV
U
Conne
ction of external m
otor protection; brid
ge if no
exte
rnal m
otor pro
tection is con
nected.
AS
DF
unction
27.01.2014
PE
P 007
/2011
3
Achim
Pfleg
er
10X
616; 10X
617;
10X
619;
-
3/3
Achim
Pfleg
er2
3.05.2011
SW
P 581 - 691; 561H
817380
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
aÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
SWP 581 / SWP 691 / SWP 561H Circuit diagram 3/3
53Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
PE
IN0V
L1UL2VL3W
-Q11
1412
11
-K1
/2.4
12
-Q0
/2.4
34
56P
E
-X1
0
M3
T1
T2
T3
PE
-M1
VD
1
ϑ-F2
MO
T/2.1
L-Steu
/2.1
1
L1,L2,L
3,PE
; pow
er su
pply, o
utput, com
pressor; clo
ckwise ro
tary fie
ld is absolute
ly necessary!
L1
Co
mpre
ssor mo
tor pro
tection
Fun
ctionU
K8
173
85b
Sta
rting cu
rrent lim
it compressor
L2
X10
13
3~P
E/400V
/50Hz
M1
auxiliaire
com
presseu
r
L3
F2
K1
Term
inal in sw
itch box h
eat pum
p
PE
22
VD
1
Operating
materials
Ma
ins conta
ctor, com
pressor
-M1
3~P
E/40
0V/50H
z
Q0
Leg
en
d:
VD
1
Q11
comp
resso
r
27.01.2014
ÄM
037
/201
3
1
Achim
Pfleg
er
10X
618;
a
1/3
Achim
Pfleg
er0
8.02.2012
SW
P 291H
817385
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
bÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
Circuit diagram 1/3 SWP 291H
54 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
MO
T/1.15
L-Steu
/1.15
PE
-X1PE
-X1
0
NN
LL
P+
-
b2c4a1
-F1
HD
P
DI1
-X2
DI2
OUT1A
1
A2
-K1
OUT5
A1
A2
-Q0
L..
-X4
L..
L..
B/
-X6
A
Green
Yellow
white
Brown
-K2
2 A/
B
ϑ
NT1
-X7
-R1
TS
G1
GND
ϑ
NT3
-R3
TW
E
GND
ϑ
NT4
-R4
TH
G
GND
ϑ
NT5
-R5
TS
G2
GND
ϑ
NT6
-R6
TV
L
GND
ϑ
NT7
-R7
TR
L
GND
ϑ
NT8
-R8
TW
A
GND
NT9
-R9
CW
GND
GND
-X8
IP
12
-B1
0H
D
AIN1
GND
IP
12
-B1
1N
D
AIN2
L/3.1
N/3.1
PE
/3.1
3 -X1
12
32
1P
E
1
12
/1.53
4/1.5
56
/1.5
1214
11/1.3
UK
8173
85b
TW
E
Q0
2
TS
G2
Hig
h-pressure sw
itch
TS
G1
TR
L
auxiliaire
compresseu
r
R8
B10
HD
Co
ntroller board; A
ttention: I-m
ax = 6A
/230V
AC
230
VA
C
3
VD
1
Ho
t gas senso
r
R1
Co
der resistance
; 18,7 kO
hm
-F1
K1
GN
D/LIN
/12V
Leg
en
d:
R4
1~N
/PE
/230V/50H
zH
igh-p
ressure sensor
K22
HD
P
R9
K20
1~N
/PE
/230V/50H
z
rt
F1
-K20
He
at source outpu
t sensor
Low
pressure
sensor
TH
G
1
TV
L
sw
He
at source inpu
t sensor
21
R5
41
23
X10
TW
AC
WT
ermina
l in switch bo
x heat p
ump
Electron
ic expansio
n valve
Fun
ction
2
R3
Suction sensor, e
vapo
rator
R7
L,N,P
E; p
ower sup
ply, controller
ND
Re
turn sensor
B11
Ma
ins contacto
r, com
pressorS
uction sensor, compre
ssor
blR
6
1
Operating
materials
Flo
w se
nsor
27.01.2014
ÄM
037
/201
3
2
Achim
Pfleg
er
10X
618;
a
2/3
Achim
Pfleg
er2
7.09.2010
SW
P 291H
817385
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
bÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
SWP 291H Circuit diagram 2/3
55Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
L/2.15
N/2.15
PE
/2.15
L-X
0N
PE
L-X
0L
L
MOT
-X2
.
ASD
EVU
-K10
MO
T
Exte
rnal flo
w rate sw
itch; bridge if no sw
itch is co
nnected.
Leg
en
d:
Energy supp
lier conta
ct; closed on relea
se; bridge if no blo
cking interva
lE
VU
Operating
materials
AS
D
Conne
ction of external m
otor protection; brid
ge if no
exte
rnal m
otor pro
tection is con
nected.
UK
8173
85
b
K10
MO
T
Fun
ction
EV
U
Controller board; A
ttentio
n: I-ma
x = 6A
/230V
AC
AS
D
27.01.2014
ÄM
037
/201
3
3
Achim
Pfleg
er
10X
618;
a
3/3
Achim
Pfleg
er2
3.05.2011
SW
P 291H
817385
12
34
56
78
91
01
11
21
31
415
16
12
34
56
78
91
01
11
21
31
415
16
bÄ
M 070/20
13
Bl von A
nz
Nam
e
Da
tum
Zu
stand
Blatt-N
r.
Bearb.
Da
tumÄ
nderun
g
Circuit diagram 3/3 SWP 291H
56 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
57Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
58 Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
59Subject to change without notice | 83053700gUK – Translation into English of the original German operating manual | ait-deutschland GmbH
IIA1
ait-deutschland GmbHIndustrie Str. 395359 KasendorfGermany
Unit model
100 615SWP 371 *SWP 451 *SWP 581 *SWP 691 *SWP 291H *SWP 561H *
EC Directives Standardized ENEN 349
EN 60529
Designated position:TÜV-SÜDIndustrie Service GmbH (Nr.:0036)
EN 60335-1/-2-40
EN ISO 13857 EN 61000-3-2/-3-3
Module
UK818163c
EN ISO 12100-1/2 EN 55014-1/-2
EN 378
* Pressure equipment component
Kasendorf, 14.12.2015Company: Place, date:
Signature:
Category
2011/65/EG
Designation of the device(s)
NumberUnit modelNumber
confirms that the following designated device(s) as designed and marketed by us fulfill thestandardized EC directives, the EC safety standards and the product-specific EC standards.In the event of modification of the device(s) without our approval, this declaration shall becomeinvalid.
The undersigned
Heat Pump
100 614
100 616100 617100 618100 619
EC Declaration of Conformity in accordance with the EC Machinery Directive 2006/42/EC, Annex II A
2006/42/EG 2009/125/EG2006/95/EG 2010/30/EU2004/108/EG*97/23/EG
Jesper StannowHead of Heating Development
ait-deutschland GmbHIndustriestraße 3D-95359 Kasendorf
E [email protected] www.alpha-innotec.de
alpha innotec – an ait-deutschland GmbH brand
UK