Operating Instructions
Sartorius EcoMix.COMPACT
Model EM02T-YCompact paint-mixing system for potentially explosive areas of Zone 2
98648-017-93
98648-017-93
No. Designation
1 Terminal/controlpanel
2 LCDdisplay(QVGA)
3 ekey(standbyswitch)
4 (QWERTY)keypad
5 Equipotentialbondingconductor
2 Operating Instructions EcoMix.COMPACT
General View of the Equipment
No. Designation
6 Adaptorconnection
(DCjack)
7 Datainterfaceport(25-pin)
8 Connector(9-pin)forthescales
1
2
4
5
6
7
83
General View of the Equipment
Operating Instructions EcoMix.COMPACT 3
User Information
User Information
About these Installation Instructions
t Pleasereadtheseinstallationinstructionscarefullybeforeputtingtheequip-
mentintooperationforthefirsttime.
t Readtheinstallationinstructionsandsafetyinstructionscarefully.
t Theseinstallationinstructionsconstituteapartoftheproduct.
Keeptheseinstallationinstructionsinasafeplacethatiseasilyaccessibletoall
personnelwhooperatethisequipment.
t Iftheseinstructionsarelost,pleasecontactSartoriusforareplacementor
downloadthelatestmanualfromourwebsite,www.sartorius.com.
Warning/Danger SymbolsWarning/dangersymbolsusedintheseinstructions:
Dangerofelectricalshock2 Dangerofphysicalinjuryordeath
Warningofpotentialphysicalinjury,3 healthriskorriskofpropertydamage
h Usefulinformationandtips
Symbols
Thefollowingsymbolsareusedintheseinstructions:
t indicatesarequiredaction
y describeswhathappensafteraparticularactionhasbeenperformed
1. Performstepsinthespecifiedorder
2.
– indicatesaniteminalist
ContentsGeneral View of the Equipment 2
User Information 3
Contents 4
Intended Use 4
Safety Instructions 4
LegalInformation 4
WarningandSafetyInstructions 5
Equipment Supplied 6
Installation 6
Getting Started 7
InstallationLocation 7
JackPlugforDCPowerSupply 7
PowerConnection 8
EquipmentDowntime 8
Operation 8
Weighing 8
Setup and Configuration 9
Care and Maintenance 12
Service 12
Repairs 12
SafetyInspection 12
Cleaning 12
CorrosiveEnvironment 12
Disposal 13
Serial Number Coding 13
Interface Description 14
Connection Diagram 15
Specifications 16
Accessories 17
Scale Drawings (Dimensions) 18
Documents 19
CMarking 19
KEMATypeExaminationCertificate 21
SafetyPrecautions 25
Intended UseTheSartoriusEcoMix.COMPACTterminal(EM02T-Y)isacompactpaint-
mixingterminalforuseinpaint-mixingapplications.
TheEcoMix.COMPACTconsistsofadisplayandcontrolunit,whichcan
beconnectedtoscales.TheEcoMix.COMPACTisimmediatelyreadyfor
useinpotentiallyexplosiveareas(Zone2)withoutanyfurtherinstallation
work.
Aconnectioncablecan(optionally)beusedtoconnecttoaPCoutsideof
thehazardousarea(inanon-hazardousarea).TheEcoMix.COMPACTcan
becontrolledwiththeusersoftwareinstalledonthePC.Ifyouwishto
createyourownapplicationsoftware,Sartoriussupplytherequireddevice
driversforDOSorWindowsoperatingsystems.
Safety Instructions
Legal Information Thisdevicecorrespondstostipulatedsafetyrequirements.
Improperuseorhandlingcan,however,resultindamageand/orinjury.
Themanufacturerisnotresponsibleforanydamagescausedbynon-
compliancewithwarningsorsafetyinstructions.
– Therequirementspertainingtoapplicableinstallationregulationsmust
befollowedwhenusingelectricalequipmentinsystemsandenviron-
mentalconditionswithincreasedsafetyrequirements.
– TheEcoMix.COMPACTcanbeusedinZone2areas.
SeetheKEMACertificateincludedintheseinstructionsandthesafety
instructions,drawingnumber36658-751-16.
– Withregardtosafety,itisassumedthatallcircuitsareearthed(equi-
potentialbonding).
– TheEcoMix.COMPACTcomplieswiththeapplicableCENELECharmo-
nizedEuropeanstandards:
EN60079-0:2006
EN60079-15:2005
– TheuseofEcoMix.COMPACTisnotpermittedinlegalmetrologyorin
medicalareasorhazardousareascontainingdustorexplosivemateri-
als.
– TheIPprotectionratingofthedeviceisIP40inaccordancewith
EN60529.ThedevicemustbehandledcarefullyaccordingtotheIP
protectionrating.
– TheEcoMix.COMPACTmeetsallrequirementsforelectromagnetic
compatibility(EMC).Interferencestrongerthanthemaximumvalues
specifiedinthestandards(seeDeclarationsofConformity)shouldbe
avoided.
– Theconnectioncables,aswellasthewiresinsidetheequipment
housing,aremadeofPVC.Chemicalsthatcorrodethismaterialmust
bekeptawayfromthesecables.Noneofthecomponentsofthe
EcoMix.COMPACTshouldbeexposedtoambienttemperaturesoutside
therangefrom0°Cto40°Cduringoperation.Sufficientventilation
mustbeprovided,inordertoavoidexcessivebuild-upofheat.
4 Operating Instructions EcoMix.COMPACT
Contents
Warning and Safety Instructions TheEcoMix.COMPACTshouldonlybeopenedbytrainedpersonnelwiththepowerdisconnected.2 Dangertolife:donottouchconductivepartsofthepowersupplywiring!
Theinstallationmustbecheckedforcorrectfunctionandsafetybyatrainedandqualifiedpersonatappropriate
intervals(e.g.checkingthecablefordamage).
Thedeviceisintendedtobeinstalledexclusivelyinlocationsthatoffersufficientprotectionagainstthepenetration
ofsolidforeignbodiesorwater.Thesafetyoftheequipmentiscompromisedbyforeignbodiesandwater.Theterminal
mustbeprotectedagainstdamageanddirectorindirectpenetrationofwaterandforeignbodies(>1mmdiameter).
Avoidgeneratingstaticelectricityonthedustcoverandtheglasspanel.Theequipotentialbondingconductor3 oftheterminalmustbeconnectedproperly,accordingtocommonlyacceptedtechnicalstandards.
Adustcovershouldbeusedtoprotectthedevicefrompaintremnants.
Onlycleanthedeviceasstipulatedinthecleaninginstructions.
Operatingpersonnelmustbetrainedtorecognizefaultyoperatingstatesandtobeableto
initiatethenecessarysafetymeasures,e.g.disconnectingtheEcoMix.COMPACTfromthepowersupply.
Proceedwithextremecautionwhenusingpre-wiredconnectioncablespurchasedfromothermanufacturers:
ThepinassignmentsofthesecablesmaynotbecompatiblewithSartoriusequipment.
OnlyusecablesandcablelengthsapprovedbySartorius.
CablesnotprovidedbySartoriusaretheresponsibilityoftheoperator.
Takecarethattheglasspaneloverthedisplayisnotdamaged(e.g.byfallingobjects).
Iftheglasspanelisdamaged,disconnectthedevicefromthepowersupplyimmediately.
AdefectivedevicemayonlyberepairedbytrainedservicetechniciansinaccordancewithSartoriusguidelines.
Onlyoriginalreplacementpartsshouldbeused.AlwaysensurethattheequipmentisdisconnectedfromACpower
beforeperforminganymaintenance,cleaning,orrepairwork.Iftheequipmentisopenedbyanyoneotherthan
personsauthorizedbySartorius,allclaimsunderthemanufacturer‘swarrantyareforfeited.
Ifnecessary,speaktoyourdealerortheSartoriusServiceCenter.
Thedevicemustbeprotectedfromaggressivechemicalvapors,unnecessarilyextremetemperatures,moisture,shocks,
andvibrations.Pleaseobservethewarningsandsafetyinstructionsintheattacheddrawing,36658-751-16.
InaccordancewithDirective94/9/EC,theEcoMix.COMPACTmodelisadeviceinCategory3,suitableforusein
Zone 2hazardousareas.
ECTypeExaminationCertificates: KEMA09ATEX0066X
Labeling: II3GExnAnLIIBT4
Operating Instructions EcoMix.COMPACT 5
Warning and safety instructions
6 Operating Instructions EcoMix.COMPACT
Installation
Equipment Suppliedt Removethedevicefromthepackaging.
Theequipmentsuppliedincludesthefollowing:
– EcoMix.COMPACTterminal
– Adaptor
– Safetyretainerwithscrewforstrainreliefofthepowersupplycable
y Afterunpackingtheequipment,checkimmediatelyforanyvisibledamage.
If youdetectanydamage,proceedasdirectedinthesafetyinstructions.
Installation
h TheEcoMix.COMPACT(terminal)isauthorizedforuseinZone2poten-
tiallyexplosiveareas.
Connecttheadaptorasshownindrawing3 36658-751-16(pagexx).
Thisexplosion-protectedsystemshouldbesetupaccordingtocommonlyaccepted
technicalstandards.Theapplicablenationalelectricalcodeandsafetyregulations
foryourparticularcountrymustbeobserved.
BeforecommissioningtheEcoMix.COMPACTinpotentiallyexplosiveareas,acheck
mustbecarriedoutbyorunderthesupervisionofaqualifiedelectriciantoensure
thatthesystemisingoodworkingorder.
Checkwhetherornotthecompetentauthorities(e.g.industrialsupervisoryboard)
needtobeinformed.Itisalsonecessarytocarryoutinspectionsofthesystemdur-
ingoperation.Inspectionintervalsshouldbesuchthatanysignificantdefectsthat
mayoccurcanbeidentifiedingoodtime.Inspectionsshouldbecarriedoutatleast
onceeverythreeyears.Theapplicablerequirementsandguidelinesoftheemploy-
ers‘liabilityinsuranceassociationshouldalsobeobservedduringoperation.
ConnecttheEcoMix.COMPACTtotheequipotentialbondingconductorusinga
suitablecable(notincluded)viatheequipotentialbondingconductorterminalon
thedevice.Thecablegaugeconformswithnationalspecifications.Installationmust
becarriedoutproperlybytrainedpersonnelandaccordingtocommonlyaccepted
technicalstandards.Thesystemshouldonlybeoperatedforthefirsttimewhenitis
certainthattheareaisnotpotentiallyexplosive.
Ifdeviationsareevidentduringstartupduetotransportdamage(e.g.nodisplay,
nobacklighting),thesystemshouldbedisconnectedfromthepowersupplyand
serviceprofessionalsshouldbecontacted.
Makeabsolutelysurethatthedeviceisunpluggedfromthepowersupply3 beforeconnecting/disconnectingdatatransferorcontrollines.
Getting StartedInstallation Location
h Chooseasuitablelocationwherethepowersupplywillnotbeexposed
todrafts,heatradiation,moistureorvibrations.
Connecting the Scales
y 1.Connectthescalesdatacablestothe9-pinEcoMixterminal
interface.
2.Tightenthescrews.
h OnlyusecablesandcablelengthsapprovedbySartorius;
seeAccessories.
CablesnotprovidedbySartoriusaretheresponsibilityoftheoperator.
Jack Plug for DC Power Supply
t ConnectthejackplugofthepowersupplycabletotheEcoMix.COMPACT
terminalconnector.
h Tomaketheplugconnectionsmoreeasily,thedevicecanbe
placedonitsside.
Placethesafetyretaineroverthejackplugand3 tightenthescrew.
Operating Instructions EcoMix.COMPACT 7
Getting Started
°C
1
2
Power Connection
t ConnecttheEcoMix.COMPACTtothepowersupplyviatheadaptor.
t Plugthepowercordintothewalloutlet(mains).
3 Followallwarningsandsafetyinstructions.Adeviceconnectedtothe
powersupplyshouldneverbeopened.Donotremoveconnectedcables.
Onlyconnectcablestothedevicewhenthepowersupplyisturnedoff.
Makesurethatthevoltageratingprintedonthisunitmatchesthe
voltageattheplaceofinstallation.Ifthevoltagespecifiedonthelabel
or thetypeofpowersupplyplugdoesnotmatchtheratingorstandard
youuse,pleasecontactyourSartoriusofficeordealer.Useonlyoriginal
Sartoriuspowersupplyunits.Theuseofcablesfromothermanufactur-
ers,eveniftheseunitshavearegisteredapprovalratingfrom anational
testinglaboratory,requirestheconsentofaqualifiedelectrician.
y TheEcoMix.COMPACTisnowswitchedon.
Equipment Downtimet Switchtheequipmenttostandbymodewhenitwillnotbeoperatedforashort
periodoftime:
Holddowntheekeyfor3seconds.
h Forlongerperiodsofdowntime,thedeviceshouldbedisconnectedfrom
thepowersupply.
Operationt Turnonthedevicewiththeekey.
y AftertheEcoMix.COMPACTisswitchedon,itwillrunanautomaticself-test.
Thistestendswiththeweightdisplayedaszero,assoonasscalesareconnected.
8 Operating Instructions EcoMix.COMPACT
Getting Started
Setup and ConfigurationSettings in the EcoMix.COMPACT Main Menu
Thisdevicecanbeindividuallyadaptedtoitsworkingenvironment.
Enterthedesiredsettingsinthesetupmenu.
t Switchoffthedevicewiththeekey.
t Holddown[S]andturnonthedeviceagainusingtheekey.
y ThesetupmenuoftheEcoMix.COMPACTappearsinthedisplay.
t UsethecursorkeysA B tomakeselectionsinthemainsetupmenu.
t PresstheLkey[ENTER]toactivatethedesiredsetting.
y Theassociatedsubmenuisdisplayed.
t ChangethedesiredsettingandactivatebypressingtheLkey[ENTER]with
a“°“.
h Ifnokeyispressedforoneminute,theprogramautomaticallyreturns
totheweighingmenu.
Language
t UsethecursorkeysA B toselectthe“Language“menuoption.
t PresstheLkey[ENTER].
y Thesubmenuisdisplayed.
t UsetheA Bcursorkeystoselectthedesiredlanguage(hereEnglish).
t PresstheLkey[ENTER].
y Activatethelanguagesettingwith“°“.
t UsetheVcursorkeytoreturntothemainmenu,ortoexitthesetupmenu,
pressthe[Esc]key.
Contrast Setting
t UsethecursorkeysA B toselectthe“Displaycontrast“menuoption.
t PresstheLkey[ENTER].
y Thecontrastmenuisdisplayed.
Operating Instructions EcoMix.COMPACT 9
Setup and Configuration
t UsethecursorkeysA B tosetthedesiredscreencontrast.PresstheLkey
[ENTER]andconfirmthedesiredcontrastsetting.
t UsetheVcursorkeytoreturntothemainmenu,ortoexitthesetupmenu,
pressthe[Esc]key.
h Ifyouselectalowsetting,thedisplaywillbeverydark.
Weighing Display
t UsethecursorkeysA B toselectthe“Weighingdisplay“menuoption.
t UsetheLkey[ENTER]toconfirmthis.
t UsetheA Bcursorkeystochoosewhetherornottheweightvalueonthe
connectedweighcellisshownontheEcoMix.COMPACTdisplay.
t PresstheLkey[ENTER]toconfirmthedesiredsetting.
t UsetheVcursorkeytoreturntothemainmenu,ortoexitthesetupmenu,
pressthe[Esc]key.
Selecting Connected Scales
t UsethecursorkeysA Btoselectthe“Scale“menuoption.
t UsetheLkey[ENTER]toconfirmthis.
t UsethecursorkeysA Btoselecttheconnectedscales.
t PresstheLkey[ENTER]toconfirmthedesiredsetting.
t UsetheVcursorkeytoreturntothemainmenu,ortoexitthesetupmenu,
pressthe[Esc]key.
10 Operating Instructions EcoMix.COMPACT
Setup and Configuration
Info
t UsetheA B cursorkeystoselectthe“Info“menuoption.
t PresstheLkey[ENTER].
y Inthe“Info“setting,informationabouttheEcoMix.COMPACTdevicesoftware
canbeaccessed.
y Thecurrentsoftwareversionandfontversionoftheterminalaredisplayed.
t PresstheVcursorkeyrepeatedlytoreturntothesetupmenu,ortoexitthe
setupmenu,pressthe[Esc]key.
Factory Settings
t UsetheA Bcursorkeystoselectthe“Factorysettings“menuoptionand
confirmusingtheLkey[ENTER].
h Thefactorysettingsforthismenuoptionaresetto“No.“
Onlychangeifnecessary,becauseallpreviousindividualsettingswill
be lost.
Thissettingthenautomaticallyreturnsto“No.“
y Withthe“Factorysettings,Yes“setting,theEcoMix.COMPACTparameterswill
bereturnedtotheiras-delivereddefaultsettings.
t PresstheVcursorkeyrepeatedlytoreturntothesetupmenu,ortoexitthe
setupmenu,pressthe[Esc]key.
y Thecurrentweightvalueappearsinthedisplay.
Operating Instructions EcoMix.COMPACT 11
Setup and Configuration
Care and Maintenance
Service
RegularservicingbyaSartoriustechnicianwillensurecontinuedfunctionalsafety.
Sartoriusoffersitscustomersservicecontractswithregularmaintenanceintervals
rangingfrom1monthto2years.
Themaintenanceintervaldependsonoperatingconditionsandtolerancerequire-
ments.
Repairs
3 Disconnectdefectiveequipmentfromthepowersupplyimmediately.
RepairworkmustbeperformedonlybyauthorizedSartoriusservicetechnicians
usingoriginalreplacementparts.Repairsperformedbyuntrainedpersonsmay
resultinconsiderablehazardsfortheuser.Ifrepairsbecomenecessaryduringthe
warrantyperiod,sendintheentireEcoMix.COMPACTdevice.
Safety Inspection
Safeoperationoftheequipmentisnolongerensured:
– ifthedevicehasvisibledamageorisnolongerworking;
– followingstorageforarelativelylongperiodinunfavorableconditions.
Inthiscase,notifytheSartoriusServiceCenter.Maintenanceandrepairwork
mayonlybeperformedbyauthorizedservicetechnicianswhohaveaccesstothe
requiredmaintenancemanualsandinstructionsandhaveattendedrelevantservice
trainingcourses.IfyouaresendingyourEcoMix.COMPACTtoberepaired:
– removeasmuchpaintresidueaspossible,anddisconnectallcablesbefore
sending,inordertoavoidanyfurtherdamage;
– encloseadescriptionoftheerror.
Cleaning
3 Makesurenoliquidenterstheinteriorofthehousing.
Donotuseanyaggressivecleaningagents,concentratedacids,alkalisolutionsor
purealcoholtocleantheequipment.
Sprayingthedevicewithwaterorblowingcompressedairthroughthedeviceisnot
permitted.
– Useabrushorasoft,dry,lint-freeclothtocleanthedevice.
Corrosive Environment
Removealltracesofcorrosivesubstancesfromthescaleonaregularbasis.
12 Operating Instructions EcoMix.COMPACT
Care and Maintenance
DisposalIfthepackagingisnolongerneeded,itcanbedisposedofbylocalwastedisposal
authorities.Thepackagingismadeofenvironmentallyfriendlymaterialsthatcan
beusedassecondaryrawmaterials.Theequipment,includingaccessoriesand
batteries,shouldnotbedisposedofasregularhouseholdwaste.EUlegislationin
MemberStatesrequireselectricalandelectronicequipmenttobecollectedsepa-
ratelyfromunsortedmunicipalwastesothatitmayberecycled.InGermanyand
severalothercountries,Sartoriusitselfassumesresponsibilityforthereturnand
legallycompliantdisposalofitselectronicandelectricalproducts.Theseproducts
maynotbeplacedwithhouseholdwasteorbroughttocollectioncentersrunby
localpublicdisposaloperations–notevenbysmallcommercialoperators.Fordis-
posalinGermanyandintheotherMemberStatesoftheEuropeanEconomicArea
(EEA),pleasecontactourlocalservicetechniciansorourServiceCenterinGoettingen,
Germany:
SartoriusServiceCenter,WeenderLandstrasse94-108,37075Goettingen,
Germany
IncountriesthatarenotmembersoftheEuropeanEconomicArea(EEA)or
wherenoSartoriussubsidiariesordealershipsarelocated,pleasecontactyourlocal
authoritiesoracommercialdisposaloperator.Priortodisposaland/orscrappingof
theequipment,anybatteriesshouldberemovedanddisposedofinlocalcollection
boxes.Sartoriuswillnottakebackequipmentcontaminatedwithhazardousmate-
rials(ABCcontamination)eitherforrepairordisposal.Pleaserefertoourwebsite
(www.sartorius.com)orcontacttheSartoriusServiceDepartmentformoredetailed
informationregardingrepairserviceaddressesorthedisposalofyourdevice.
Serial Number Coding
Themanufacturedateofthisdeviceisencodedintheserialnumber.
Thestructureisasfollows:
YMMxxxxx
Y Year
1 2000–2006
2 2007–2013
3 2014–2020,etc.
TheYcolumnindicatestheyeargroup,whichcoversaperiodof7years.
Withineachyeargroup,themonths(MM)arecountedupto13.
2007 13-24
2010 49-60
...
Example: 249xxxxx(January2010)xxxxxisaconsecutivenumber,
increasingbyoneeverymonth.
Operating Instructions EcoMix.COMPACT 13
Disposal
Interface Port
GeneralInformation:
AnyPCcanbeconnectedviatheinterfaceport.
TheinterfacecanbeusedaseitheraRS-232orRS-422port.
Theinterfaceiselectricallyconnectedtothehousing(protectiveconductor).
Theinterfacecablesareshieldedandbothendsofeachcableareelectrically
connectedtotheconnectorcasing.
Thisconnectionmayresultininterferencecausedbygroundloopsortransient
currentsifthehousinghasbeengroundedorconnectedtotheprotectivegrounding
conductor.Ifnecessary,connectanequipotentialbondingconductortothe
equipment.
Pin Assignments for the 25-pin DSUB
Signal DSUB ConnectorRXD232 2
TXD232 3
SGND 7
+5V 13
RS422ENABLE 14
KBDDATA 15
TXD422 16
TXD422 17
RXD422 18
KBDCLOCK 19
RXD422 23
Providealow-resistanceconnectionbetweenshieldandconnectorcasing.
h CablesnotsuppliedbySartoriusoftenhaveapinassignmentthatdiffersfrom
theassignmentusedbySartorius.Therefore,beforeyouconnectthecabletothe
EcoMix.COMPACT,checkthepinassignmentofyourcableanddisconnectanylines
withpinassignmentsthatdifferfromthatofSartorius.
FailuretodosomaydamagetheEcoMix.COMPACTorcauseittomalfunction.
14 Operating Instructions EcoMix.COMPACT
Interface Port
1
14
13
25
Connection Diagram
EcoMix.COMPACT RS232/V24 PC
TheEcoMix.COMPACTisequippedwitha120Ohmloadresistorasstandard.
Operating Instructions EcoMix.COMPACT 15
Connection Diagram
EcoMix.Compact RS422 Connector D-Sub PC 25-pin
TxD 16
TxD 17
RxD 23
RxD 18
14
GND 7
EcoMix.Compact RS232/V24 Connector D-Sub PC 25-pin 9-pin/25-pol.
RxD 2 3/2 TxD 3 2/3
GND 7 7/7
The max. cable length is 20 m.
R
R
TxD
RxD
GND
Specifications
EcoMix.COMPACT (EM02T-Y)
Housing(dimensions) 243+245+303mm
Netweight,approx. 3.45kg
Dustandwaterprotectionrating IP40(inaccordancewithIEC529)
Interface RS-232orRS-422
Ambient Conditions
Environment Forindooruseonly
Ambienttemperature:Storageandshipping –10°Cto+60°C
Ambienttemperature:Operation 0to+40°C
Highestrelativehumidity: 80%fortemperaturesupto31°C,decreasinglinearlyupto50%relative
humidityfor40°C
Power Connection
ConnectiontoACpowersourcevia 230VACor115VACdependingonnationalversion,–20%to+15%
Sartoriusadaptor;seeAccessories
Primary 230VAC122mA,12VA/115VAC,240mA,12VA
Secondary 14.5DC/1A/14.5VA
Safety of Electrical Equipment accordingtoEN61010-1:2001
Safetyrequirementsforelectricalequipmentformeasurement,control,and
laboratoryuse–Part1:Generalrequirements
Electromagnetic Compatibility inaccordancewithEN61326-1:2006
Electricalequipmentformeasurement,control,andlaboratoryuse
EMCrequirements–Part1:Generalrequirements
Definedimmunitytointerference: Basicrequirements
Emissions: ClassB:suitableforuseinresidentialareasandareasthataredirectly
connectedtoalowvoltagenetwork.
16 Operating Instructions EcoMix.COMPACT
Specifications
Accessories
Description Order No.
Dustcover YDC02EM
Connecting AccessoriesPeripheraldevicescanbeconnectedtotheinterfaceportontheEcoMix.Compact.
Sartoriussuppliesappropriateaccessoriesforthispurpose.
Pleasenotethesafetyprecautions,36658-751-16(page24).
Description Order No.
DatacableforconnectiontoPMAscales YCC01-0041M3
DatacableforconnectiontoPC,RS-232 YCC01-0029M20
DatacableforconnectiontoPC,USB YCO14
DatacableandaccessoriesforRS-422datacommunicationcanbeobtainedon
request.
Adaptor
Description Order No.
ING1/.../A:
EC Europe 6971476
GB UnitedKingdom 6971890
US(115V) USA 6971480
Furthercountry-specificadaptorsareavailableuponrequest.
Operating Instructions EcoMix.COMPACT 17
Accessories
Scale Drawings (Dimensions)
Dimensionsinmillimeters.
18 Operating Instructions EcoMix.COMPACT
Scale Drawings (Dimensions)
A-A 164
6
4580
A
A235.6
246.3
42.3
Wandmontage / wall assembly
X
80
243.6
102.8120
40°
X 50°
245
267
238.4
164
Wallassembly
Operating Instructions EcoMix.COMPACT 19
Documents
20 Operating Instructions EcoMix.COMPACT
Documents
Operating Instructions EcoMix.COMPACT 21
Documents
22 Operating Instructions EcoMix.COMPACT
Documents
Operating Instructions EcoMix.COMPACT 23
Documents
Page 2of1
36658-751-16Safety Instructions and Information
April 16, 2009
Dr. Klausgrete Drawing No.
Designation
Revision 00
1. Power connection
Zone 2 hazardous areaGas group IIB, temperature class T4Ambient temperature: 0°C to +40°C
Non-hazardous area
Power supplyING1..../A
II 3 G EEx nC IIB T4KEMA 05ATEX1248X
2. Data transfer Data transfer only; no power may be supplied from the connected equipment to the EM02.-Y
The equipment may also be installed in zone 2 if it is suitable for category 3G in accordance with ATEX Directives.
Secure plug so that it cannot become accidentally disconnected. Ensure that an emergency off switch is available.
Plug
Alternative connections
Use explosion-protected plug
EcoMix.COMPACTEM02.-Y
II 3 G Ex nA nL IIB T4KEMA 09ATEX0066X
Scale / weigh cellPMA7501.-Y
KEMA 05ATEX1248XII 3 G EEx nA nL IIB T4
8
3
8
1
2
5
4
625-pinD-SUB 8
5
Alternative power supply
7
9-pinD-SUB
8
8
8
9
9
5
9-pinD-SUB
24 Operating Instructions EcoMix.COMPACT
Documents
Page 2of2
36658-751-16Safety Instructions and Information
April 16, 2009
Dr. Klausgrete Drawing No.
Designation
Revision 00
These safety instructions apply to the installation, operation, maintenance and repair of the equipment.
The numbers given in parentheses are the position numbers on page 1.
1. The power supply (1), control panel (2) and the scale/weigh cell (3) may be used only in this combination and only as non-portable equipment in zone 2.
2. As an alternative to power supply (1), an alternative power supply source (7) may be used, provided that it does not exceed the maximum ratings of 30 V and 1 A.
3. As an alternative to scale/weigh cell (3) of type PMA7501.-Y (KEMA 05ATEX1248X), a different scale or weigh cell may be used if it is designed according to type of explosion protection Ex n and is approved for gas group IIB and temperature class T4, and its power supply inputs may be loaded with a voltage of up to 30V and a current of up to 1A.
4. The equipment must be installed by an authorized specialist in compliance with applicable laws, rules and regulations, ordinances and standards. In particular, be sure to conform to the European Standard EN 60079-14 (Electrical apparatus for use in potentially explosive gas atmospheres).
5. Be sure to follow the installation, operating, maintenance and servicing instructions given in the manuals supplied.
6. Use the equipment only within the temperature range specified. Do not expose the equipment to any impermissible sources of heat or cold, sunlight or vibration. Be sure that the equipment is installed so that sufficient heat dissipation can take place all around the equipment and that the equipment is sufficiently spaced apart from external heat sources.
7. Protect the power cable (4) from damage and properly connect it to the power supply (120 or 230 Vac; be sure to check that the rating on the power supply is appropriate for the line voltage/mains supply of your country). The power supply is permitted for circuits up to 1,500 A. Use the power cable inside the hazardous area/location only with the approved explosion-protected plug. Alternative: Secure the plug from becoming disconnected or directly connect the cable to the equipment; in the latter case, be sure to provide an emergency off switch.
8. For the power cable (4), supply cable (5) and the data cable (6), make sure to use suitable cabling with regard to the applicable zone classification, type of installation, electrical load and mechanical stress, provided that these cables are notalready supplied with the equipment. The equipment operator shall be responsible and liable for the safety of cables supplied by manufacturers other than Sartorius.
9. All metal parts (housing) must be electrically connected to the terminal for the equipotential bonding conductor (PA) (9).The equipment operator is obligated to connect a lead with a gauge of at least 4 mm² (cross section) to the PA terminal in a suitable location. For this purpose, fasteners (screws) may be used. The low resistance of this connection to the PA busbar must be checked when the system is installed at the intended place of use. The equipment operator shall be responsible and liable for preventing static electricity.
10. Secure connections (8) from becoming disconnected (for example, use the safety retainers supplied). Seal the unused connections (8) so that IP protection is ensured.
11. Before opening the equipment, turn off the power or ensure that the area does not have a potentially explosive atmosphere. Inside the hazardous area, do not connect or disconnect cables under load!
12. If the equipment does not operate properly, unplug it immediately from line power (mains supply)!
13. Prevent the effects of stray current (e.g., caused by magnetic fields) by ensuring suitable installation.
14. Keep chemicals that can corrode the housing seals and cable sheaths away from the equipment. These include oil, grease, benzene, chlorinated and aromatic solvents, caustics and acids, acetone and ozone. If you are not sure about the safety of a certain substance, please contact the manufacturer.
15. At reasonable intervals, have your equipment installation checked for proper functioning and safety by a specialist trained and certified for this purpose.
16. If your equipment needs to be repaired, use only original spare parts supplied by the manufacturer.
17. Any tampering with the equipment by anyone, other than repair work performed by authorized Sartorius personnel, will result in the loss of EX conformity for zone 2 and in the forfeiture of all claims under the manufacturer's warranty. Only authorizedspecialists may open the equipment.
18. Modifications, including those to be carried out by Sartorius employees, may be permitted only after express written authorization has been obtained from Sartorius.
19. These safety instructions and information are supplementary and do not release the equipment operator from his or her responsibility for the installation, operation and testing of the equipment according to the standards, directives, regulations,ordinances and laws currently in force.
Documents
Operating Instructions EcoMix.COMPACT 25
SartoriusWeighingTechnologyGmbH
WeenderLandstrasse94–108
37075Goettingen,Germany
Phone+49.551.308.0
Fax +49.551.308.3289
www.sartorius.com
Copyrightby
SartoriusWeighingTechnologyGmbH,
Goettingen,Germany.
Allrightsreserved.Nopart
ofthispublicationmay
bereprintedortranslatedin
anyformorbyanymeans
withoutthepriorwritten
permissionofSartorius.
Thestatusoftheinformation,
specificationsandillustrations
inthismanualisindicated
bythedategivenbelow.
Sartoriusreservesthe
righttomakechangesto
thetechnology,features,specifications
anddesignof
theequipmentwithoutnotice.
Status:
November2012,
SartoriusWeighingTechnologyGmbH,
Goettingen,Germany
PrintedinGermanyonpaperthathasbeenbleached
withoutanyuseofchlorine
W1/EcoMixCompact·KT
PublicationNo.:WEM6004-e12112