Oniplast DIN 8062

1
DIN 8062 DIMENSIONAL CHART OF uPVC PIPES AS PER DIN 8062 All dimensions in mm Nominal Diameter (Nominal Size) Mean Outside Diameter Wall ickness of Pipes of Series of 1 2 3 4 5 6 Min Max Min Max Min Max Min Max Min Max Min Max Min Max 20 20 20.2 1.5 1.9 2.3 2.8 25 25 25.2 1.5 1.9 1.9 2.3 2.8 3.3 32 32 32.2 1.8 2.2 2.4 2.9 3.6 4.2 40 40 40.2 1.8 2.2 1.9 2.3 3 3.5 4.5 5.2 50 50 50.2 1.8 2.2 2.4 2.9 3.7 4.3 5.6 6.4 63 63 63.2 1.9 2.3 3 3.5 4.7 5.4 7 7.9 75 75 75.3 1.8 2.2 2.2 2.7 3.6 4.2 5.6 6.4 8.4 9.5 90 90 90.3 1.8 2.2 2.7 3.2 4.3 5 6.7 7.6 10 11.2 110 110 110.3 1.8 2.2 2.2 2.7 3.2 3.8 5.3 6.1 8.2 9.3 12.3 13.8 125 125 125.3 1.8 2.2 2.5 3 3.7 4.3 6 6.8 9.3 10.5 13.9 15.5 140 140 140.4 1.8 2.2 2.8 3.3 4.1 4.8 6.7 7.6 10.4 11.7 16.6 17.4 160 160 160.4 1.8 2.2 3.2 3.8 4.7 5.4 7.7 8.7 11.9 13.3 17.8 19.8 180 180 180.4 1.8 2.2 3.6 4.2 5.3 6.1 8.6 9.7 13.4 15 20 22.2 200 200 200.4 1.8 2.2 4 4.6 5.9 6.7 9.6 10.8 14.9 16.6 22.3 24.8 225 225 225.5 1.8 2.2 4.5 5.2 6.6 7.5 10.8 12.1 16.7 18 25 27.7 250 250 250.5 2 2.4 4.9 5.6 7.3 8.3 11.9 13.3 18.6 20.7 27.8 30.8 280 280 280.6 2.3 2.8 5.5 6.3 8.2 9.3 13.4 15 20.8 23.1 315 315 315.6 2.5 3 6.2 7.1 9.2 10.4 15 16.7 23.4 26 355 355 355.7 2.9 3.4 7 7.9 10.4 11.7 16.9 18.8 26.3 29.2 400 400 400.7 3.2 3.8 7.9 8.9 11.7 13.1 19.1 21.3 29.7 32.9 450 450 450.8 3.6 4.2 8.9 10 13.2 14.8 21.5 23.9 500 500 500.9 4 4.6 9.8 11 14.6 16.3 23.9 26.5 560 560 561 4.5 5.2 11 12.3 16.4 18.3 26.7 29.6 630 630 631.1 5 5.7 12.4 13.9 18.4 20.5 30 33.2 710 710 711.2 5.7 6.5 14 15.6 20.7 23 800 800 801.3 6.4 7.3 15.7 17.5 23.3 25.9 900 900 901.5 7.2 8.2 17.7 19.7 26.3 29.2 1000 1000 1001.6 8 9 19.7 21.9 29.2 32.4 Recommended Working Pressure in BAR for conveyance of water and harmless fluids to which Rigid PVC is resistant (to refer DIN 2403, March 1965 issue, Section 7.2 & DIN 16929) Temperature up to 0 C 20 To refer Note 1 below 4 6 10 16 To refer Note 2 below 40 2.5 4 6 10 60 1 2.5 Note: 1) Pipe Series 1 is stipulated as special series for construction of Ventilation Pipes 2) Pipe Series 6 is stipulated as special series for construction of Pipeline and Apparatus in chemical industry. is pipes at least withstand the pressure Series 5. ey have a bigger wall thicknesses than Pipes of Series 5 witth a view to suitability for welding and plastic foaming. 3) Pipe Series 2, 3, 4 & 5 are suiotable for conveyance foe Water and are harmless (to refer DIN 2403, March 1965 issue, Section 7.2) Fluids to which rigid PVC is resistant (to refer DIN 16929)

Transcript of Oniplast DIN 8062

Page 1: Oniplast DIN 8062

DIN 8062DIMENSIONAL CHART OF uPVC PIPES AS PER DIN 8062 

All dimensions in mmNominal Diameter (Nominal

Size)

Mean Outside Diameter 

Wall Thickness of Pipes of Series of1 2 3 4 5 6

Min Max Min Max Min Max Min Max Min Max Min Max Min Max

20 20 20.2 1.5 1.9 2.3 2.825 25 25.2 1.5 1.9 1.9 2.3 2.8 3.332 32 32.2 1.8 2.2 2.4 2.9 3.6 4.240 40 40.2 1.8 2.2 1.9 2.3 3 3.5 4.5 5.250 50 50.2 1.8 2.2 2.4 2.9 3.7 4.3 5.6 6.463 63 63.2 1.9 2.3 3 3.5 4.7 5.4 7 7.975 75 75.3 1.8 2.2 2.2 2.7 3.6 4.2 5.6 6.4 8.4 9.590 90 90.3 1.8 2.2 2.7 3.2 4.3 5 6.7 7.6 10 11.2

110 110 110.3 1.8 2.2 2.2 2.7 3.2 3.8 5.3 6.1 8.2 9.3 12.3 13.8125 125 125.3 1.8 2.2 2.5 3 3.7 4.3 6 6.8 9.3 10.5 13.9 15.5140 140 140.4 1.8 2.2 2.8 3.3 4.1 4.8 6.7 7.6 10.4 11.7 16.6 17.4160 160 160.4 1.8 2.2 3.2 3.8 4.7 5.4 7.7 8.7 11.9 13.3 17.8 19.8180 180 180.4 1.8 2.2 3.6 4.2 5.3 6.1 8.6 9.7 13.4 15 20 22.2200 200 200.4 1.8 2.2 4 4.6 5.9 6.7 9.6 10.8 14.9 16.6 22.3 24.8225 225 225.5 1.8 2.2 4.5 5.2 6.6 7.5 10.8 12.1 16.7 18 25 27.7250 250 250.5 2 2.4 4.9 5.6 7.3 8.3 11.9 13.3 18.6 20.7 27.8 30.8280 280 280.6 2.3 2.8 5.5 6.3 8.2 9.3 13.4 15 20.8 23.1315 315 315.6 2.5 3 6.2 7.1 9.2 10.4 15 16.7 23.4 26355 355 355.7 2.9 3.4 7 7.9 10.4 11.7 16.9 18.8 26.3 29.2400 400 400.7 3.2 3.8 7.9 8.9 11.7 13.1 19.1 21.3 29.7 32.9450 450 450.8 3.6 4.2 8.9 10 13.2 14.8 21.5 23.9500 500 500.9 4 4.6 9.8 11 14.6 16.3 23.9 26.5560 560 561 4.5 5.2 11 12.3 16.4 18.3 26.7 29.6630 630 631.1 5 5.7 12.4 13.9 18.4 20.5 30 33.2710 710 711.2 5.7 6.5 14 15.6 20.7 23800 800 801.3 6.4 7.3 15.7 17.5 23.3 25.9900 900 901.5 7.2 8.2 17.7 19.7 26.3 29.2

1000 1000 1001.6 8 9 19.7 21.9 29.2 32.4Recommended Working Pressure in BAR for conveyance of water and harmless fluids to which Rigid PVC is resistant (to refer DIN 2403, March 1965

issue, Section 7.2 & DIN 16929)

Temperature up to 0 C

20To refer Note 1

below

4 6 10 16To refer Note 2

below40 2.5 4 6 1060 1 2.5

Note:

1) Pipe Series 1 is stipulated as special series for construction of Ventilation Pipes2) Pipe Series 6 is stipulated as special series for construction of Pipeline and Apparatus in chemical industry. This pipes at least withstand the pressure Series 5.  They have a bigger wall thicknesses than Pipes of Series 5 witth a view to suitability for welding and plastic foaming.3) Pipe Series 2, 3, 4 & 5 are suiotable for conveyance foe Water and are harmless (to refer DIN 2403, March 1965 issue, Section 7.2) Fluids to which rigid PVC is resistant (to refer DIN 16929)