One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along...

37
One step towards True Along Hole logging depths: proper WLL corrections Amsterdam ICSWSA meeting 30 th October 2014 Harald Bolt Ton Loermans 1

Transcript of One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along...

Page 1: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

One step towards True Along Hole logging

depths: proper WLL corrections

Amsterdam ICSWSA meeting

30th October 2014

Harald Bolt

Ton Loermans

1

Page 2: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Why work on depth QC??• Depth one of the top uncertainty factors

FDP’s• Sensitivity analysis Net Present Value

typical FDP

• Direct impact fluid contacts on HC vol.– Extreme case: >>> 1 million bbl per 1 ft change in

GOC 2

Change in NPV FDP for assumed uncertainty in various parameters

Page 3: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Accuracy & precision needed

• Fluid contacts

–A few feet difference has major impact

3

- Not many examplesabout lateral error mishaps.

(…yet … )

Page 4: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

AH-depth and 3D position

• Limit to AH depth

• Surveying needed for 3D position

– AH depth (often) important input

• Plenty of problems challenges already

4

Page 5: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Current practice• Wireline – loggers depth

–Normally (some) stretch corrections applied

• LWD logs – drillers depth

–Surface measured lengths

–No stretch corrections applies

• Hence grossly in error; errors not consistent

• WLL depths (used to be) believed as being better than drillers depth

–But LWD/drillers depth taken for lack of WL in horizontals

5

Page 6: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

heptacable

5” drillpipe

Drillpipe and logging cable

6

Page 7: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

heptacable

5” drillpipe

Drillpipe and logging cable

7

The WLL challenge: get a really good (accurate) measurement even withsuch flimsy cable..!!)

Page 8: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Depth problems common• Random field example

– 25 well field

– 7 wells with serious depth problems suspected

– 4 wells resurveyed confirmed significant problemsoriginal depths

• errors from -12 to +28 ft (< 10000 ft wells)

• (suspected) errors & mismatches jumping up & down

– one well, WLL only: 19, 29, 10, 21, 10, 30, 2 ft

– WLL/LWD mix: similar problems

• 25 % of wells have reason to worry, / too large depth discrepancy (Saudi Aramco 2013)

8

Page 9: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Depth

Why worry about depth?

“Normal work”, eg stretching and squeezing core photos

of solid pieces of rock to match LWD depths

Current NS well:

•Drilled just for depth problem

earlier well

•Still not sure how to tackle

now..

!!!!!

9

Depth mishaps

t r i a n g le

Page 10: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Depth

Why worry about depth?

“Normal work”, eg stretching and squeezing core photos

of solid pieces of rock to match LWD depths

Current NS well:

•Drilled just for depth problem

earlier well

•Still not sure how to tackle

now..

!!!!!

10

Page 11: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Cause of problems??

• Inadequate QC service companies??

– “type 1 errors” logging depths are simplywrong, so logs have to be shifted

• Lack of audit trail/documentationleading to “type 2” error

–Operator shifts logs, assuming they’re wrong, tomatch existing model

• “Quest for depth” (started mid 1990’s) focussed on improvementsQM/QC/audit trail

11

Page 12: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

QC not main problem; methods fall short

• Problems (often/mostly?) not from operational errors

–Not much difference various regions/countries

–Not much difference after QC improvement campaign

–Stretch profile more complicated than traditionally assumed for smooth vertical wells

12

Page 13: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

QC not main problem; methods fall short

• Problems (often/mostly?) not from operational errors

–Not much difference various regions/countries

–Not much difference after QC improvement campaign

–Stretch profile more complicated than traditionally assumed for smooth vertical wells

13

Page 14: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Improve stretch corrections

• Current stretch corrections developedfor simple, smooth, vertical wells

–Two point correction OK

• Need improved corrections (for bothWLL and LWD)

–Newly development routines for (marked cable) WLL routines seem a major step forward

14

Page 15: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Harald Bolt (ICT Europe)

15

Page 16: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Measurehead systems

16courtesy of Schlumbergercourtesy of MPA and BenchMark© ICT Europe s.a.

Page 17: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Calibrate, verify and correct

17

• Calibrate the cable length• Verify cable length measurements• Environmental corrections

• Uncertainty statements• Audit trail

© ICT Europe s.a.

Page 18: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Calibrated line length

18

dual wheelmeasurehead

calibrated tension measurement device at,

or near, the measurehead

line tension measurement

enc. 1

enc. 2 wireline drum

sheave

sheave

cablehead tension

magnetic mark detector

actual cable magnetic mark

Magnetic marks => line length(measurehead interpolation between marks)Surface tension + CHT => interval line stretchΔ Line tension changes => Δ correction changesΔ tension inter-mark => Δ stretch increments

Requires:magnetic marked cablecalibrated tension devices(calibrated measurehead)

Note: changes in line tension and well bore friction =>changes in inter-mark distance =>environmental correction to line length

© ICT Europe s.a.

Page 19: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Verification of depth

The difference between individual measurewheelencoder responses (per mark) are logged and compared.

19

Use high resolution encoders (typ. 600 ppf).Inter-mark distance will depend on tension and st. coeff.

Cable IPD will be seen as a change in gain on both encoder responses.

© ICT Europe s.a.

Page 20: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Measurewheel verification

Enc.2Enc.1

mag.mark sequence number

mag.mark sequence number

Run-1

Run-2

100’ mag.markdifference, ft

20

RIH sequence POOH sequence

HUD

© ICT Europe s.a.

Page 21: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Measurewheel problem example

RIH data

POOH data

Δ Enc.1 – Enc.2

Δ Enc.1 – Enc.2

Δ Ind.Depth – Enc.1

Δ Ind.Depth – Enc.1

Δ Enc.1 – Enc.2, ft Δ Ind.Depth – Enc.1, ft

21

RIH sequence

POOH sequence

© ICT Europe s.a.

Page 22: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Correction basics – elastic stretch

• Hooke’s Law

• General stretch equation

• Total stretch applicable to WL correction

22

© ICT Europe s.a.

Page 23: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Stretch coefficient behaviour

23

As wireline design complexity increases, the complexity of the stretch coefficient increases

© ICT Europe s.a.

Page 24: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

HUD st.coeff - example

24© ICT Europe s.a.

Page 25: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

HUD st.coeff testing

25© ICT Europe s.a.

Page 26: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Magnetic mark defined st.coeff

Using a marked cable and a calibrated measurehead,St.Coeff and tension determines the inter-mark distance

26

This assumes that cable IPD has been worked out.

© ICT Europe s.a.

Page 27: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Way-point measurement method

27

Surf.Ten

CHT

Casing

Casing

© ICT Europe s.a.

Page 28: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Available technologies and processes

28

Calibrated Cable Length Cable calibration verification• Thermal expansion• Stretch Coefficient Calibration• Stretch Coefficient ProfilingHUD Stretch Coefficient Real Time Stretch Coefficient• Straight Line Stretch CorrectionWay-Point Depth with Correction• Way-Point Depth with Real-Time Stretch Coefficient

© ICT Europe s.a.

Page 29: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Simple case correction comparisons ??

ind.depth

ind.depth, fttension, lbs Ind. – corr.depth, ft

data sequence number

Surf.Ten

CHT

29

Elastic St.Corr

Log-down/-upcorrection

casing shoe

Δ = 5 ft

Δ = 3 ft

Δ = 8 ft

© ICT Europe s.a.

Page 30: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Complex comparisons ??

ind.depth

ind.depth, fttension, lbs Ind. – corr.depth, ft

data sequence number

Surf.Ten

CHT

30

Elastic St.Corr

Log-down/-upcorrection

casing shoe

Δ = 14 ft

Δ = 3 ftΔ = 10 ft

© ICT Europe s.a.

Page 31: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Wrap up

31

Page 32: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

TAH depth consortium (isn)Joint activity service companies, operators

– Main objectives: provide standards andrecommended practices for TAH depthdetermination WLL and LWD

– Expand and hone this new WLL correctionsmethod

• Consider “wheels only” WLL

• Further quantification uncertainties/errors needed

– Agree on methods for LWD stretch corrections

• Obvious ISCWSA collaboration potential

32

Page 33: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Conclusions

1. WLL and LWD need better along hole depths

2. Proper corrections to get to real TAH (True Along Hole) depth for bothLWD & WLL possible

– New method shown for marked cable WLL

– Better than 2 / 10000 achievable

– TAH depth consortium can deliver all what is needed

33

Page 34: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

34

Page 35: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

35

Page 36: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

36

DIY fire truck model building kit

Page 37: One step towards True Along Hole logging depths: proper ... · 1. WLL and LWD need better along hole depths 2. Proper corrections to get to real TAH (True Along Hole) depth for both

Improve stretch corrections

• Current stretch corrections developed for simple, smooth, vertical wells

–Two point correction OK

• Need improved corrections (for both WLL and LWD)

–Tension/friction profile along well; then (simply) Hooke

–Various approaches made & published; some (even better?) coming

37

Taken from Chia,

2006