One Page for Site Installation v2.0

5
3 2 1 0 0 1 2 3 4 5 25mm 2 DC Power Cable DC Rectifier External Alarming Box 5 4 25mm 2 Grounding Cable External Alarming Cable DDF Grounding Bar Grounding Post FE cable IDU/SW GSM 900M GSM 1800M UMTS 2100M Part 1 BS8800 UBPG2UBPG1BPK North region connect to slot 1(RSU82 900M) South region connect to slot 2(RSU60E 900M) If UMTS only connect to slot 5(RSU82 2100M) To FCE MON cable connection

description

bklkl

Transcript of One Page for Site Installation v2.0

  • 3 2 1 0

    0 1 2 3 4 5

    25mm2 DC

    Power Cable

    DC

    Rectifier

    External

    Alarming Box

    5 4

    25mm2 Grounding Cable

    External Alarming

    Cable

    DDF

    Grounding

    Bar

    Grounding

    Post

    FE cable IDU/SWGSM 900M GSM 1800M UMTS 2100M

    Part 1 BS8800

    UBPG2

    UBPG1

    BPK

    North region connect to slot 1(RSU82 900M)South region connect to slot 2(RSU60E 900M)If UMTS only connect to slot 5(RSU82 2100M)

    To FCE

    MON cable connection

  • To IDU

    SCSI 50RS232/485 ETH_1MON

    To DC power

    To external alarms

    ETH_0 BBU_1 BBU_0E1/T1

    LPU

    To FS 0 To FS1 To FS2 To FS3 To FS4 To FS5

    To FAN

    GSM

    900M

    GSM

    1800MUMTS 2100M

    0 1 2 3 4 5

    Part 2 BS8900A

    PM3

    SA

    To FCE

    North region connect to slot 1(RSU82 900M)South region connect to slot 2(RSU60E 900M)If UMTS only connect to slot 5(RSU82 2100M)

    IDU up-side down in BC8910A

    MON cable connection

  • Sector 1

    2100M

    Sector 2

    2100M

    Sector 3

    2100M

    ASBT ASBT ASBT

    NSBT NSBT

    Y-T

    yp

    e AIS

    G C

    able

    AISG Cable AISG Cable AISG Cable

    To

    RS

    U

    82

    AN

    T1

    To

    RS

    U

    82

    AN

    T2

    To

    RS

    U

    82

    AN

    T3

    To

    RS

    U

    82

    AN

    T4

    To

    RS

    U

    40

    AN

    T1

    To

    RS

    U

    40

    AN

    T2

    To

    RS

    U

    82

    AIS

    G

    Part 3 UMTS feeder system

    AB1

    B2

  • Part 4 SA board jumper setting(120ohm)

  • TO BBU FS port

    PART 4 Distributed site ZXSDR BS8700 without RET

    jumpers

    Grounding Bar

    -45+45

    Sector 2

    jumpers

    -45 +45

    TX/RX RXDSector 1

    PIM

    DC

    PWR

    To DCPD4

    12345

    6 7 8 9

    10

    R8881

    Jumper

    OUT1

    PWR Mon LC1

    PGND

    16mm2

    16mm2

    Tx/Rx Rx

    PIMDC

    To DCPD4

    -45+45

    TX/RX RXDSector 1

    TO BBU FS port

    One page for site insatllation v2.0.vsdBS8800BS8900AUMTS feederSA board jumper settingR8882