Oli DurneyLBTI Optical EngineerSteward ObservatoryUniversity of Arizona

NIC Aperture, Pupil, and Filter Wheel Positions

Rev. 2.3September 19, 2011

Page 2: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 2

Revision History PowerPoint File Name Version Date Modified Changes from Previous Version

NIC M

echanisms

NIC Wheel Positions v1.0.ppt 1.0 01-26-11 Original version, PhaseCam wheels (Pupil, FW1, FW2, ND)

NIC Wheel Positions v1.1.ppt 1.1 01-27-11 Include CAD drawing of ND wheel, added Prism & Optics wheels

NIC Wheel Positions v1.2.ppt 1.2 02-01-11 Flip Prism and Optics CAD orientations, colorize filters, change titles

NIC Wheel Positions v1.3.ppt 1.3 02-03-11 Update Notes, add Optics & Prism cell exploded views, add NAC wheel, re-order slides

NIC Wheel Positions v1.4.ppt 1.4 02-15-11 Add LMIRCam Filter wheels #1-4, add LMIRCam Aperture wheel

NIC Wheel Positions v1.5.ppt 1.5 02-21-11 Revise ‘drawn as’ comment, add red circle for optical axis and Note

NIC Wheel Positions v1.6.ppt 1.6 03-08-11 Change filters in LMIRCam FW#2

NIC Wheel Positions v1.7.ppt 1.7 04-20-11 Add Large & Small Beam Diverter, Image Dichroic, ID 3D view, Left & Right Shutter

NIC Wheel Positions v1.8.ppt 1.8 04-20-11 Add ‘controlled by’ comment, add NAC Source

NIC Wheel Positions v1.9.ppt 1.9 04-22-11 Add Shutter 3D views

NIC Wheel Positions v2.0.ppt 2.0 04-28-11 Reverse rotation direction and order of NAC wheel, add pinholes in Pos 3 & 6

NIC Wheel Positions v2.1.ppt 2.1 04-29-11 Reverse rotation direction and order of LMIRCam FW#2, Add Revision History

NIC Wheel Positions v2.2.ppt 2.2 05-03-11Add ‘Steps’ column to all slides, situate ‘Home’ in between Pos 5&6 on NAC slide, revise text on Image Dichroic slide, add red optical axis to all other slides, revise ‘Note’ accordingly

NIC Wheel Positions v2.3.ppt 2.3 09-19-11 Add 12-hole and 24-hole aperture masks in Pos 6&7 of LMIRCam FW#1, illustration shows installed orientation of hole patterns

Page 3: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 3

ND Wheel - Assembly• Neutral Density filter set: P/N FX90-0100 from Janos

Technology

• Drawn as viewed with cover plate removed from Access Port side (side facing PICNIC Detector)

• CW rotation of motor = CW rotation of wheel

• Controlled by Motor Box #2, Drive #1

Position Steps Description Dimensions

1 (Home) Open =25.4mm

2 OD=0.50, T=31.62% =25.4mm, t=1mm

3 OD=1.00, T=10.00% =25.4mm, t=1mm

4 OD=2.00, T=1.00% =25.4mm, t=1mm

5 OD=3.00, T=0.10% =25.4mm, t=1mm

NOTE: Optical Axis (Exit Port) is shown in red and is located at Position 1 when Wheel is in the Home position, Pos 1 will be replaced with an A/R coated ZnSe window

1

2

34

5

CW

Page 4: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 4

Optics Wheel – Assembly• CaF2 re-imaging lenses from ISP Optics

• Drawn as viewed with cover plate removed from flat side (side facing PICNIC Detector)

• CW rotation of motor = CW rotation of wheel

• Controlled by Motor Box #2, Drive #2

NOTE: Optical Axis (Exit Port) is shown in red and is located at Position 1 when Wheel is in the Home position

Position Steps Description Dimensions

1 (Home) Open Open

2 Dual Large Lenses =9.5mm, t=2.8mm

3 Open Open

4 Mixed Large/Small =9.5mm, t=2.8mm

Lenses =8.5mm, t=2.8mm

5 Open Open

6 Dual Small Lenses =8.5mm, t=2.8mm

43

1

5

2

6

CW

Page 5: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 5

Optics Wheel – CellsDual Large Lenses Dual Small LensesMixed Large/Small Lenses

Page 6: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 6

Prism Wheel - Assembly• Neutral Density filter set: P/N FX90-0100 from Janos

Technology

• Drawn as viewed with cover plate removed from Baffle Tube side (side facing Field Lenses)

• CW rotation of motor = CW rotation of wheel

• Controlled by motor Box #2, Drive #3

Position Steps Description Dimensions

1 (Home) Open Open

2 Dual Triplet Prisms 12x12mm

3 H Filter =25.4mm

4 Single Triplet Prism 12x12mm

with H Filter

5 K Filter =25.4mm

6 Single Triplet Prism 12x12mm

with K Filter

CW1 4

5

23

6

NOTE: Optical Axis (Entrance Port) is shown in red and is located at Position 1 when Wheel is in the Home position

Page 7: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 7

Prism Wheel – CellsDual Triplet Prisms Single Triplet Prism with Filter

Page 8: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 8

NAC Aperture Wheel• ZnSe lenses and mirror from Edmund Optics

• Drawn as viewed from cryostat Window side

• CWW rotation of motor = CWW rotation of wheel

• Controlled by Motor Box #2, Drive #4

Position Steps Name Size

1 (Home) 0 Open 42.86 x 42.86mm

2 100000 ZnSe Lens and 45° =25.4mm

Fold Mirror

3 200000 5 mm Aperture =25.4mm

4 300000 Znse Lens =25.4mm

5 400000 3x3 Grid of Pinholes 36.46 x 36.46mm

=1mm, d=8.94mm

6 500000 50 m Pinhole =25.4mm

NOTE: Optical Axis (Entrance Port) is shown in red and is located at Position 1 when Wheel is in the Home position

1

653

4

2CCW

Page 9: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 9

NAC Source Slide• Wires installed on 03-07-11

• Drawn as viewed from cryostat Window side

• CW rotation of motor = vertical translation of the slide ??

• Controlled by Motor Box #1, Drive #7

Position Steps AWG Size

1 30 0.0100”

2 40 0.0310”

3 40 0.0310”

4 48 0.0012”

5 48 0.0012”

6 30 0.0100”

7 40 0.0310”

8 40 0.0310”

9 48 0.0012”

10 48 0.0012”

1

2

3

4

5

6

7

89

10

Move

(Home)

NOTE: Pos 6-10 are not currently working (05-03-11). However, the wires are installed.

1

2

3

4

5

6

7

89

10

Back View

Page 10: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 10

LMIRCam Filter Wheel #1• Single Apertures installed on 01-21-11, Hole patterns

installed on 09-16-11

• Drawn as viewed with cover plate removed from Baffle Tube side (side facing LMIRCam Dichroic)

• CW rotation of motor = CCW rotation of wheel

• Controlled by LMIRCam Motor Box, Drive #1

1

1195

3 CCW

Position Steps Name Size

1 (Home) Open 25.4mm

2 Small Dual Aperture ~7.19mm

3 Large Dual Aperture ~7.49mm

4 Left Aperture ~8.16mm

5 Right Aperture ~8.21mm

6 24-hole Pattern 25.4mm

7 12-hole Pattern 25.4mm

8 Open 25.4mm

9 Open 25.4mm

10 Open 25.4mm

11 Pinhole ~0.33mm

12 Blank 25.4mm

72

4

6 8

10

12

NOTE: Optical Axis (Entrance Port) is shown in red and is located at Position 1 when Wheel is in the Home position

Page 11: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 11

LMIRCam Filter Wheel #2• All filter retainer rings adjusted on 01-19-11, H & J filters

installed on 03-08-11

• Drawn as viewed with cover plate removed from flat side (side facing LMIRCam Baseplate)

• CCW rotation of motor = CCW rotation of wheel

• Controlled by LMIRCam Motor Box, Drive #2

7

5311

9 CCW

Position Steps Name Size

1 (Home) Open 25.4mm

2 Ks (2.00-2.32 m) 25.4mm

3 H (1.50-1.81 m) 25.4mm

4 J (1.18-1.36 m ) 25.4mm

5 L-spec (2.81-4.00 m) 25.4mm

6 M-long (4.60-5.86 m) 25.4mm

7 Std ‘M’ (4.60-4.97 m) 25.4mm

8 L-long 2 (3.81-4.05 m) 25.4mm

9 L-long 1 (3.51-4.06 m) 25.4mm

10 Std ‘L’ (3.41-3.99 m) 25.4mm

11 L-short (3.10-3.51 m) 25.4mm

12 Blank 25.4mm

18

10

12 2

4

6

NOTE: Optical Axis (Exit Port) is shown in red and is located at Position 1 when Wheel is in the Home position

Page 12: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 12

LMIRCam Filter Wheel #3• New filter (Pos 10) installed on May 11, 2010

• Drawn as viewed with cover plate removed from Baffle Tube side (side facing Biconic #2)

• CW rotation of motor = CCW rotation of wheel

• Controlled by LMIRCam Motor Box, Drive #3

10

862

12 CCW

Position Steps Name Size

1 (Home) Open 25.4mm

2 H2O Ice 1 (2.96-3.12 m) 25.4mm

3 H2O Ice 2 (3.01-3.15 m) 25.4mm

4 PAH 1 (3.26-3.31 m) 25.4mm

5 PAH 2 (3.38-3.43 m) 25.4mm

6 Br- (4.02-4.09 m) 25.4mm

7 Br- off (3.97-4.04 m) 25.4mm

8 L-cont 1 (3.13-3.20 m) 25.4mm

9 L-cont 2 (3.39-3.54 m) 25.4mm

10 L-cont 3 (3.55-3.64 m) 25.4mm

11 L-cont 4 (3.68-3.88 m) 25.4mm

12 Blank 25.4mm

411

1

3 5

7

9

NOTE: Optical Axis (Entrance Port) is shown in red and is located at Position 1 when Wheel is in the Home position

Page 13: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 13

LMIRCam Filter Wheel #4• PK-50 Blocker not installed because of OD clearance

concern (substrate delivered with 2 chips)

• Drawn as viewed with cover plate removed from Baffle Tube side (side facing detector)

• CW rotation of motor = CW rotation of wheel

• Controlled by LMIRCam Motor Box, Drive #4

10

1226

8 CW

Position Steps Name Size

1 (Home) Open 25.4mm

2 Blank 25.4mm

3 PK-50 Blocker 25.4mm

4 Pupil Imaging Lens (ZnSe)12.7mm

5 Open 25.4mm

6 Open 25.4mm

7 Open 25.4mm

8 Open 25.4mm

9 Open 25.4mm

10 Open 25.4mm

11 Open 25.4mm

12 Open 25.4mm

49

7

5 3

1

11

NOTE: Optical Axis (Exit Port) is shown in red and is located at Position 1 when Wheel is in the Home position

Page 14: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 14

4

3CW

LMIRCam Aperture Wheel• New filter (Pos 10) installed on May 11, 2010

• Drawn as viewed with cover plate removed from side opposite cryo-motor (side facing Biconic #2)

• CW rotation of motor = CW rotation of wheel

• Controlled by LMIRCam Motor Box, Drive #5

Position Steps Name Size

1 (Home) Open 50.8x50.8mm

2 Open 50.8x50.8mm

3 Pinhole 1mm?

4 Blank 50.8x50.8mm

1

2

NOTE: Optical Axis (Exit Port) is shown in red and is located at Position 1 when Wheel is in the Home position

Page 15: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 15

Large Beam Diverter Slide• Two (2) possible configurations for the Beam Diverter –

Large (2-position) and Small (3-position)

• Drawn as viewed from entrance Window

• CW rotation of motor = right translation of the slide ??

• Controlled by Motor Box #1, Drive #6

Position Steps Name Size

1 (Home) Open 72x57mm

2 Large Dichroic 74x58x7mm

1 2Position of 1 when 2 is centered along the optical axis

Move

NOTE: Position 1 nominally houses the Large Mirror. It is currently removed to allow an open path to LMIRCam

Optical Axis is shown in red and is located at Position 1 when Slide is in the Home position

Page 16: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 16

Image Dichroic Slide• Drawn as viewed from entrance Window

• CW rotation of motor = right translation of the slide ??

• Controlled by Motor Box #1, Drive #1

Position Steps Name Size

1 (Home) Open 72x57mm

2 Large Dichroic 74x58x7mm 1 2

Move

NOTE: Optical Axis is shown in red and is located at Position 1 when Slide is in the Home position

Page 17: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 17

Image Dichroic AssemblyFront View

Side View

ISO View

Page 18: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 18

Right Shutter• Shutter located in front of Fixed Nulling Mirror

• Drawn as viewed from entrance Window

• Controlled by Motor Box #1, Drive #2

Position Steps Name Size

1 (Home) Vertical – half open 20mm

2 Closed 20mm

3 Horizontal – half open 20mm

4 Open 20mm

1 2

3 4NOTE: Optical Axis is shown in red

Page 19: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 19

Left Shutter• Shutter located in front of Field Steering Mirror

• Drawn as viewed from entrance Window

• Controlled by Motor Box #1, Drive #3

Position Steps Name Size

1 (Home) Vertical – half open 20mm

2 Closed 20mm

3 Horizontal – half open 20mm

4 Open 20mm

1 2

3 4NOTE: Optical Axis is shown in red

Page 20: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 20

Shutter AssembliesLeft Shutter Right Shutter

Page 21: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 21

Additional Slides

Page 22: Oli Durney LBTI Optical Engineer Steward Observatory University of Arizona

OFD 22

Small Beam Diverter Slide• Two (2) possible configurations for the Beam Diverter –

Large (2-position) and Small (3-position)

• Drawn as viewed from entrance Window

• Controlled by Motor Box #1, Drive #6

Position Steps Name Size

1 Open 42x30mm

2 (Home) Small Mirror 52x32x9.53mm

3 Small Dichroic 54x38x7mm

2 3

Move

1

Move

NOTE: Position 1 is Open when slide is moved to Position 2. It is Small Mirror when slide is moved to Position 3

Optical Axis is shown in red and is located at Position 2 when Slide is in the Home position