Oil Record Book entries: Machinery space operations

8
Including January 2011 amendments to Technical Bulletin 24 Technical Bulletin NUMBER 35 2011 (revised from Bulletin 24) UK P&I CLUB Oil Record Book entries: Machinery space operations (Part 1) The Club’s Inspectors have noted that the above subject does not seem to be either clear cut or well understood by ships’ officers or MARPOL inspectors. IMO guidance on entries in the Oil Record Book (ORB) has also been ambiguous in the past. However, IMO recently brought out (November 2010) a new MEPC Circular 736 in an attempt to clarify and standardise ORB entries with the revision of the ORB under Resolution MEPC.187(59) which came into force on 1 January 2011. The Club would suggest a standard format for entries described in the MEPC circular should be adopted on all Club entered vessels as soon as possible to avoid the possibility of fines from PSC or others for incorrect record keeping. A comprehensive listing of machinery space items to be recorded in the ORB as appropriate, is included in Appendix III of Annex 1 to MARPOL 73/78 as amended, and the standardised entry system in the circular from IMO. All entries must be in ink, pencil in any log record should be avoided, and all entries should be recorded at the time of the operation to avoid possible mistakes. The areas of most concern to the Club are the entries required when: Related to oil residue (sludge and other residues) retained on board the vessel. Transferring or disposing of oil residues. Operating the Oily Water Separator, when non automatic disposal methods are used. Transferring and collecting bilge water to the bilge tanks and any oil residue (sludge) content of the bilges. Related to other operations required under Section (I).

description

Oil Record Book entries:Machinery space operations.The Club’s Inspectors have noted that the above subject does not seem to be either clear cut or well understood by ships’ officers or MARPOL inspectors.

Transcript of Oil Record Book entries: Machinery space operations

Page 1: Oil Record Book entries:  Machinery space operations

Including January 2011 amendments to Technical Bulletin 24

Technical BulletinNUMBER 35 2011 (revised from Bulletin 24)

UK P&I CLUB

Oil Record Book entries:Machinery space operations (Part 1)

The Club’s Inspectors have noted that the above subject does not seem to be either clear cut or wellunderstood by ships’ officers or MARPOL inspectors. IMO guidance on entries in the Oil Record Book(ORB) has also been ambiguous in the past. However, IMO recently brought out (November 2010) a newMEPC Circular 736 in an attempt to clarify and standardise ORB entries with the revision of the ORBunder Resolution MEPC.187(59) which came into force on 1 January 2011.

The Club would suggest a standard format for entries described in the MEPC circular should be adoptedon all Club entered vessels as soon as possible to avoid the possibility of fines from PSC or others forincorrect record keeping.

A comprehensive listing of machinery space items to be recorded in the ORB as appropriate, is included inAppendix III of Annex 1 to MARPOL 73/78 as amended, and the standardised entry system in the circularfrom IMO.

All entries must be in ink, pencil in any log record should be avoided, and all entries should be recorded atthe time of the operation to avoid possible mistakes.

The areas of most concern to the Club are the entries required when:

● Related to oil residue (sludge and other residues) retained on board the vessel.

● Transferring or disposing of oil residues.

● Operating the Oily Water Separator, when non automatic disposal methods are used.

● Transferring and collecting bilge water to the bilge tanks and any oil residue (sludge) content ofthe bilges.

● Related to other operations required under Section (I).

Page 2: Oil Record Book entries:  Machinery space operations

Tank Tank location Tank volumeindentification Frames (from-to) Lateral position m3

Waste Oil Tank 116-118 Port 13.4

F.O. Sludge Tank 120-121 Port 6.0

L.O. Sludge Tank 120-121 Starboard 6.0

TOTAL VOLUME 25.4 m3

Tank Tank location Tank volumeindentification Frames (from-to) Lateral position m3

Dirty Bilge Tank 125-134 Centre line 27.0

500

TOTAL VOLUME 27.0 m3

* Oily bilgewater holding tank(s) are not required by the Convention; if such tank(s) are provided they shall be listed in Table 3.3.

Example of IOPP Cert Form A (or B):

3 Means for retention and disposal of oil residues (sludge) (regulation 17) and bilge waterholding tank(s)*

3.1 The ship is provided with oil residue (sludge) tanks as follows:

3.2 Means for the disposal of oil residue (sludge) retained in oil residue (sludge) tanks:

3.2.1 Incinerator for oil residues (sludge), maximum capacity...............kW or kcal /h(delete as appropriate)

3.2.2 Auxiliary boiler suitable for burning oil residues (sludge).........................................

3.2.3 Other acceptable means, state which................................................................

3.3 The ship is provided with holding tank(s) for the retention on board of oily bilge water asfollows:

Entries under Section (C)Section (C) 11, Collection of oil residues

(C) Collection and disposal of oil residues (sludge)

11 Collection of oil residues.

Quantities of oil residues (sludge) retained on board. The quantity should be recorded weekly:*(This means that the quantity must be recorded once a week even if the voyage lasts morethan 1 week.).

11.1 – identity of tank(s)...........................................................

11.2 – capacity of tank(s)......................................................... m3

11.3 – total quantity of retention................................................ m3

11.4 – quantity of residue collected by manual operation............ m3

(Operator initiated manual collections where oil residue (sludge) is transferredinto the oil residue (sludge) holding tank(s))

* Tanks listed in item 3.1 of forms A and B of the supplement in the IOPP Certificate used for sludge.

It should be noted that entries under this heading are now weekly at all times, whether at sea or in port, butnever more than once a week, and should include all tanks mentioned in section 3.1 only of Form A or B of theInternational Oil Pollution Prevention (IOPP) Certificate, and only these tanks. Other tanks and bilge water shouldbe included under a different heading.

Manual collections should be recorded when they occur and separate to the weekly ROB sludge records.

Page 3: Oil Record Book entries:  Machinery space operations

Note: Operator initiated manual collection where oil residue (sludge) is transferred into the 3.1 tanks could include,but not be limited to:

1. Transfer of sludge from separator drain tanks (fuel or lub oils)

2. Transfers of oil residues from engine sump tanks

3. Addings any oils to a sludge tank from any source (all oils in the tank are then considered sludge)

4. Collection of sludge from the bilge water holding tanks – in this case an entry for the disposal of bilge wateris also required.

* The use of Code C 11.4 came into force from 1 January 2011.

Section (C )12, Methods of disposal

(C) Collection and disposal of oil residues (sludge and other oil residues)

12 Methods of disposal of residue

State quantity of oil residues disposed of, the tank(s) emptied and the quantity of contents retained:

12.1 To reception facilities (indentify port);*

12.2 Transferred to another(other) tank(s) [indicate tank(s) and the total content of tank(s)];

12.3 Incinerated (indicate total time of operation);

12.4 Other method (state which).

* Ships’ masters should obtain from the operator of the reception facilities, which includes barges and tank trucks, areceipt or certificate detailing the quantity of tank washings, dirty ballast, residues or oily mixtures transferred, togetherwith the time and date of the transfer. This receipt or certificate, if attached to the Oil Record Book, may aid the master ofthe ship in proving that his ship was not involved in an alleged pollution incident. The receipt or certificate should be kepttogether with the Oil Record Book, Part 1.

Example: ORB entry for manual collection of residues would read as follows:

04/Jan/2011 C 11.1 Waste Oil Tank

11.2 13.4m3

11.3 9.8m3

11.4 3.5m3 collected from Bilge Holding Tank

4/E Ian Wilkins 04/Jan/2011 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

*

Example: ORB entry made weekly would read as follows:

30/Nov/2010 C 11.1 Waste Oil Tank

11.2 13.4m3

11.3 6.3m3

C/E Jim Binder, 30/Nov/2010 signed: Jim Binder30/Nov/2010 C 11.1 L.O. Sludge Tank

11.2 6.0m3

11.3 3.2m3

C/E Jim Binder, 30/Nov/2010 signed: Jim Binder30/Nov/2010 C 11.1 F.O. Sludge Tank

11.2 6.0m3

11.3 1.0m3

C/E Jim Binder, 30/Nov/2010 signed: Jim Binder

Date Code Item Record of operations/Signature of officer in charge

Page 4: Oil Record Book entries:  Machinery space operations

Example 2: Internal transfer between tanks under 3.1 to tanks of 3.1 or 3.3 of Form A (or B):

12/Dec/2010 C 12.2 0.8m3 water drained from Waste Oil Tank, 9.0m3 retained to

Dirty Bilge Tank (3.3), ROB Dirty Bilge Tank 22m3

C/E Jim Binder, 12/Dec/2010 signed: Jim Binder

Date Code Item Record of operations/Signature of officer in charge

Note: Each tank disposed should be entered separately even if all are included in the single receipt. Also all tanks inform A (or B) including 3.1 and 3.3 tanks should be included under this heading.

Note: Only one entry required as the ROB in the bilge tank is included here.

Example 3: Transfer from one sludge tank to another sludge tank designated under 3.1 of Form A (or B):

12/Dec/2010 C 12.2 0.8m3 sludge transferred from F.O. Sludge Tank, 0.3m3 retained to

Waste Oil Tank, 9.9m3 retained

C/E Jim Binder, 12/Dec/2010 signed: Jim Binder

Date Code Item Record of operations/Signature of officer in charge

Example 4: Incineration of sludge from 3.1 or 3.2.3 tanks in Form A (or B):

12/Dec/2010 C 12.3 0.8m3 sludge from Waste Oil Tank, 9.1m3 retained

Burned in incinerator for 08 hours

C/E Jim Binder, 12/Dec/2010 signed: Jim Binder

Date Code Item Record of operations/Signature of officer in charge

Example 5: Burning of sludge in the boiler:

12/Dec/2010 C 12.4 3.8m3 sludge from Waste Oil Tank, 6.0m3 retained

Burned in boiler for 08 hours

C/E Jim Binder, 12/Dec/2010 signed: Jim Binder

Date Code Item Record of operations/Signature of officer in charge

Example 7: Regeneration of fuel oil (only allowed if permitted under IOPCC supplement):

12/Dec/2010 C 12.4 9.1m3 of sludge disposed by regeneration of 7.5m3 fuel in F.O. Deep Tank

and 1.6m3 water in Dirty Bilge Tank

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Example 6: Evaporation of water from sludge in tank listed in 3.1 of Form A (or B):

12/Dec/2010 C 12.4 0.8m3 water evaporated from Waste Oil Tank, 9.1m3 retained

C/E Jim Binder, 12/Dec/2010 signed: Jim Binder

Date Code Item Record of operations/Signature of officer in charge

Example 1: Disposal of shore reception facilities:

12/Dec/2010 C 12.1 9.5m3 sludge from Waste Oil Tank, 0.3m3 retained

To shore facility during port stay Pusan, South Korea

C/E Jim Binder, 12/Dec/2010 signed: Jim Binder

Date Code Item Record of operations/Signature of officer in charge

Page 5: Oil Record Book entries:  Machinery space operations

(D) Non-automatic discharge overboard or disposal otherwise of bilge water which hasaccumulated in machinery spaces

13 Quantity discharged or disposed of, in m3 *

14 Time of discharge, transfer or disposal (start and stop)

15 Method of discharge, transfer or disposal:

15.1 Through 15 ppm equipment (state position at start and end);

15.2 To reception facilities (indentify port);**

15.3 To slop tank or holding tank or other tank(s), [indicate tank(s); state quantity retained intank(s), in m3].***

* In case of discharge or disposal of bilge water from holding tank(s), state identity and capacity of holding tank(s) andquantity retained in holding tank.

** The ship’s masters should obtain from the operator of the reception facilities, which includes barges and tank trucks, areceipt or certificate detailing the quantity of tank washings, dirty ballast, residues or oily mixtures transferred, togetherwith the time and date of the transfer. This receipt or certificate, if attached to the Oil Record Book, may aid the master ofthe ship in proving that his ship was not involved in an alleged pollution incident. The receipt or certificate should be kepttogether with the Oil Record Book, Part 1.

*** In case of discharge or disposal of bilge water from holding tank(s), state the identity and capacity of holding tank(s) andquantity retained in holding tank.

Entries under Section (D)

Example 1: Disposal of bilge water overboard via 15ppm equipment:

12/Dec/2010 D 13 2.5m3 of bilge water from Dirty Bilge Tank, capacity 27m3, 14.3m3 retained

14 Start: 08.00, stop: 11.30

15.1 Through 15ppm equipment overboard

Position start: 35 deg 15 min N, 126 deg 31 min E

Position stop: 35 deg 00 min N, 126 deg 04 min E

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Note: Code I entries for the unsealing and re-sealing of the overboard valve will also be required as detailed below.

Example 2: Disposal of bilge water to shore reception facilities:

12/Dec/2010 D 13 15m3 of bilge water from Dirty Bilge Tank, capacity 27m3, 0.5m3 retained

14 Start: 08.00, stop: 11.30

15.2 Pumped to shore reception facilities Pusan, South Korea

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Example 3: Pumping from bilges to a bilge tank:

12/Dec/2010 D 13 0.5m3 of bilge water from engine room bilge wells

14 Start: 08.00, stop: 11.30

15.3 To Dirty Bilge Tank, 15.5m3 retained in tank

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Page 6: Oil Record Book entries:  Machinery space operations

Note: We would stress that the system must be in a totally automated state, switching itself on and off, andautomatically operating the required valves and pumps without any personnel present for the operation to beconsidered automatic, otherwise code D should be used. In the case of automatic operation of the OWS unit acode I entry unsealing and opening the overboard valve prior to setting the operation to fully automatic mode mustbe made as well, and a second code I entry re-sealing the overboard valve is also required after the E 18 entry attime of stopping automatic operation, entry examples for these are shown under Code I below.

(E) Automatic starting of discharge overboard, transfer or disposal otherwise of bilge waterwhich has accumulated in machinery spaces

16 Time and position of the ship at which the system has been put into automatic mode ofoperation for discharge overboard, through 15ppm equipment

17 Time when the system has been put into automatic mode of operation for transfer ofbilge water to holding tank (identify tank)

18 Time when the system has been put into manual operation.

Entries under Section (E)

Usage of Code I: Additional operational procedures and general remarks

Note: A Code C 11.4 entry will also be required if this is a manual operator initiated operation.

Example 4: Pumping from Bilge Tank to an oil residue (sludge) tank:

12/Dec/2010 D 13 1.5m3 of bilge water from Dirty Bilge Tank, now 12.5m3

14 Start: 08.00, stop: 11.30

15.3 Collected in Waste Oil Tank, 10.5m3 retained in tank

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Example 1: Pumping from bilge tank automatically via 15ppm OWS unit :

12/Dec/2010 E 16 OWS unit start at 09.00 at 35 deg 15 min N, 126 deg 31 min E

from Dirty Bilge Tank

18 Stop 12.00

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Example 2: Automatic transfer from bilge well(s) to a tank:

12/Dec/2010 E 17 Transfer start 09.00 to Dirty Bilge Tank

18 Stop 10.00

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Example 1: Optional sealing of MARPOL Annex 1 related valve and/or equipment:

12/Dec/2010 I Overboard valve (no 23) from 15ppm bilge separator unit sealed

Seal no: D156783

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Page 7: Oil Record Book entries:  Machinery space operations

Note: This item should be recorded every week directly after the weekly record of items under Code C 11.1/C 11.2/C 11.3 for oil residue (sludge) tank(s) in section 3.1 of Form A (or B).

Entries under Section (H)Section (H) (repeated below) is the requirement for quantities of ALL BUNKERED OILS to be recorded in “tonnes”and not in m3. As far as we are aware this is the only diversion from the convention to record all other quantities in m3.

To avoid fines levied by port state control authorities we advise Members to pay attention to this point. The regulationas stated in the Guidelines is given below for reference;

Example 2: Breaking of optional sealing of MARPOL Annex 1 related valve and/or equipment:

12/Dec/2010 I Overboard valve (no 23) from 15ppm bilge separator unit

unsealed for normal operation of 15ppm equipment

Seal no: D156783

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Example 3: Testing of 15ppm alarm of bilge separator unit:

12/Dec/2010 I 15ppm alarm unit of the bilge separator unit tested and found satisfactory.

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Example 4: Cleaning of 15ppm bilge separator unit:

12/Dec/2010 I Opened and inspected bilge separator unit, filters cleaned as required.

After maintenance separator and 15ppm alarm unit

tested and found satisfactory.

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

Example 5: Voluntary weekly declaration of bilge tank retention quantity:

12/Dec/2010 I Weekly inventory of Bilge Water Tank(s) (listed under item 3.3) .

Dirty Bilge Tank, capacity 27.0m3, 15.0m3 retained.

4/E Ian Wilkins 12/Dec/2010 signed: Ian Wilkins

Date Code Item Record of operations/Signature of officer in charge

(H) 26 Bunkering of fuel or bulk lubricating oil

26.1 Place of bunkering

26.2 Time of bunkering.

26.3 Type and quantity of fuel oil and identity of tank(s) (state quantity added, in tonnes and total contentof tank(s)).

26.4 Type and quantity of lubricating oil and identity of tank(s) (state quantity added, in tonnes and totalcontent of tank(s)).

Section (H) 26, Bunkering of fuel or bulk lubricating oil

Page 8: Oil Record Book entries:  Machinery space operations

UK P&I CLUBIS MANAGEDBY THOMASMILLER

For further information please contact:Loss Prevention Department, Thomas Miller P&I LtdTel: +44 20 7204 2307. Fax +44 20 7283 6517Email: [email protected]

Example: ORB entry for bunkering lubricating oil would read as follows:

30/Jan/2011 H 26.1 Shanghai

26.2 Start 04.00. Stop 13.00

26.4 25 tonnes of cylinder oil bunkered in tanks:

25 tonnes added to cylinder oil holding tank

Now containing 32 tonnes

C/E Jim Binder, 30/Jan/2011 signed: Jim Binder

Date Code Item Record of operations/Signature of officer in charge

Example: ORB entry for bunkering fuel or diesel would read as follows:

30/Jan/2011 H 26.1 Shanghai

26.2 Start 04.00. Stop 13.00

26.3 Heavy fuel oil ISO 380cst, 1.0% sulphur bunkered in tanks

aaaa Forward deep tanks P/S 850 tonnes added now

containing 1450 tonnes

bbbb Aft deep tanks P/S 600 tonnes added now

containing 2400 tonnes

C/E Jim Binder, 30/Jan/2011 signed: Jim Binder