O CO NO SO - Instrumatics Inc 3000 (4... · C External probe for ambient temperature and relative...
Transcript of O CO NO SO - Instrumatics Inc 3000 (4... · C External probe for ambient temperature and relative...
NEW
eurotron
UniGas
BTU 3000+
BTU 3000+
Innovative Instrumentation SolutionsA unit of E instruments Group LLC
eurotron
UniGas
Innovative Instrumentation Solutionswww.einstrumentsgroup.com
E INSTRUMENTS
GROUP LLC
1
3
4
5
6
7
8
2
9
NO
N-C
ON
TR
AC
TD
OC
UM
EN
T-
SU
BJE
CT
TO
CH
AN
GE
E Instruments Group LLC
e-mail: [email protected] UniGas is a member of E Instruments Group LLC
172 Middletown BlvdSuite B 201
Langhorne, PA 19047Tel: 215 750 1212Fax: 215 750 1399
Distributed by:
Bulle
ttin
06-2
2.3
US
-ed.11/2
004
All descriptions are related to a fully optioned instrument. See last page for the different configurations.
Professional Combustion Analyzer
Built-In Impact Printer
Rechargeable Battery
Easy to Use, Text and Keyboard
in any Language
Stores up to 250 Samples
Graphic Display
Upgradable using Flash
Memory
9 INSTRUMENTS IN 1:
Designed to meet BS7927, TUV,
ISO, Gastec QA Criteria, GOST,
Qualigaz, and UNI 10389
Multifunction Unit for the Complete Maintenance of your Boiler
Combustion GasAnalyzer
Draft & DifferentialPressure Meter
2 ChannelThermometer
Ambient CO Monitor
Gas Pipework LeakTester
Gas Leak Detector
Ionization Flame Tester
O2
CO2
CO
Efficiency
Excess Air
DifferentialPressure
TairTgas
CO/CO2
Ratio
Ambient COMonitor
Gas LeakDetector
NO/NO & SO
Emissions AnalyserX 2
NOX
T+RH%Probe
Temperature &Humidity Meter
SO2
F7828000Manual pump for smokeindex measurements
BB830006Pt100 remote air sensorwith cone
BB610051
BB610046
7” (TGD - Temperature, Gas, Draft)sampling probe
12” (TGD - Temperature, Gas,Draft) sampling probe
BB880028
BB880033ABS rigid carrying case
Aluminium carrying case
F2139000Pipe Velcro Tc type K
F21371005” Contact type K Tc
BB830009A COmbient probe
Ambient T+RH% probe
Gas sniffer probe
BB830008
BB830010
BB880043Compact rigid carrying case withshoulder stap. BTU 3000+, probes, andaccessories need 1/3 of the classiccarrying case space.
EE300088Pressure probe andburner hose kit(single hose)
F21321005” air type KTc
BB290040DC Auto Adapter
BB830019Ionization current probe
Accessories Ordering Code
Table A Sensor n.1
Table B Sensor n.2
Table C Sensor n.3 Sensor n.4
Table D Sample probes
Table E Options
Table G Accessories
Table H Report of calibration
1 O (0-25%)
2 CO (0-8000 ppm)2X CO (0-20000 ppm)
0 none4 NO (0-4000 ppm) / NO
5 NO (0-1000 ppm) NO (0-1000 ppm)
6 SO (0-4000 ppm) SO (0-4000 ppm)
(including water trap and line filter)0 none1D 7” flue gas probe + draft (dual hose) BB6100513 12” flue gas probe + draft (dual hose) BB6100465D 29.5” flue gas probe + draft (dual hose) BB6100806 3.5” 90° flue gas or draft (single hose) probe BB6100437 6.3” multipoint flue gas (single hose) probe for
atmospheric boilers BB610070
0 none1 Built-in impact printer3 Gas network leak test procedure with pressure decay
programme4 Graphic display capability (bargraph)6 Electrovalve for automatic/manual CO exlusion
2 230V ±10% 50/60Hz - Schuko plug3 230V ±10% 50/60Hz - UK plug4 230V ±10% 50/60Hz - European plug5 100V ±10% 50/60Hz - USA/Japan plug
0 None1 Software GasConfig + DBGas2000 + IR/RS232 adapter2 Magnetic plate3V Vinyl case with shoulder strap3 ABS carrying case4 Aluminum carrying case5 Remote combustion air temperature sensor with 2m
cable and positionning cone7 Differential pressure connection kit (dual hose)8 External probe for CO operator safety9 External probe for gas leak detectorB Manual pump for smoke index measurement with filters
and comparison tableC External probe for ambient temperature and relative
umidityD External probe for boiler ionization currentE DC Auto battery charger
1 E-Instruments
2
X
2 2
2 2
Table F Mains adapter / charger1 115V ±10% 50/60Hz - USA plug
Modular Design GivingTotal Flexibility
cat. 7823 - A - B - C C - D - E - F - G - H
Low-N
ORe
ady!
x
eurotron
UniGas
Innovative Instrumentation Solutions
Multifunction Unit forComplete Maintenanceof your Boiler
The handheldprovides the latest tecnology in fluegas analysis. One instruments withmany features:
NEW BTU 3000+
.
.
.
.
.
.
.
.
up to 4 gas sensors;
CO sensor with manual orautomatic protection;
built-in impact printer;
water, air, surface temperaturemeasurements;
draft, gauge and differentialpressure measurements;
searching for presence andlocation of gas leaks;
operator safety with ambient COcontinuous monitoring;
ambient temperature and relativehumidity measurements.
One Instrument withMany Functions
Easy Replaceable Gas Sensors
CO Sensor Protection
Keyboard & Display
BTU 3000+ uses long life, lowmaintenance sensors. Alarm levelswith audible buzzer on gasmeasurements.
An automatic device can exlude theCO sensor in presence of high COlevel.
Text, menu, and keyboard available inmost common languages (not icons)for simple and intuitive operations.Engineering units are selectable bykeyboard.The large backlight graphic LCD candisplay 3, 6 or 12 values per page(ZOOM function) or with bargraphformat.
Standard Report of Calibration
Rechargeable Battery Operations
Multi Fuel Selection
Each instrument is factory calibratedand certified against E-InstrumentsStandard to ensure traceability, andshipped with a Report of Calibration.
Ni-MH rechargeable batteries providelonger field use. Flue gas analyzerand internal printer is powered by abattery pack. Charger is supplied asstandard.
BTU 3000+ provides up to 10 fuels forcalculating combustion values.
Most used fuels for your country arepre-loaded from factory. Others fuelscan be added using GasConfig PCsoftware.
morereadable, long lasting and heatresistant
as pipework leak withpressure decay programme
An external optional probe isavailable for continuoussurveillance of the ambient and
Built-In Impact Printer
Pressure/Draft input
Smoke Index
Gas Sampling Probe
Combustion Air TemperatureProbe
CO Ambient Monitoring
The instrument has an optional internaland rugged printer. It uses a low costcommon roll of paper. Certainly
than the thermal printout onchemical paper.
Smoke index measurement isperformed by using the optionalexternal hand pump. The results canbe stored in the internal memory andprinted on the report.
Flue gas sampling probes, withdifferent lengths and shapes, areavailable to match each specificrequirement. The sampling probe isconnected to the instrument with asingle or dual hose through a watertrap and a suspended particle filter.
A remote Pt100 probe isavailable for remotecombustion air temperaturemeasurement. This probe isstrongly recommended mainlyin forced air boiler to obtain anaccurate efficiencymeasurement.
Differential pressure input to verify: lowpressure, draft, g
, pressurein gas pipework, pressure in
combustion chamber, P on filters and
fan, pressure switches calibration.
Patent pending to inhibit water into theinstrument. External, to prevent risk ofinstrument damage. Large watertank capacity for condensationboiler. Small rubber cup foreasy water purge. Long lifepaper filter.
∆
Proprietary Design Trap
To check gas pipework for the presenceof leaks using a pressure decay programand the internal pressure sensor.
An external probe is available fortemperature and relative humidity(T+RH%) of the ambient for comfortindex computation.
Gas Leak Snifferexternal
Ionization Flame Tester
Flash Memory
An probe is available to locatethe position of a gas leak. This probehas a flexible stainless steel shaft toreach difficult locations.
Checks the ionization current in flamecontrol sensor.
T+RH Ambient Monitoring
The flash memory allows the instrumentto be configured by updating the UniGasfirmware for any future legislationrequirement or product performanceupgrading.
Providing theProfessional Toolfor Heating Engineers
Specifications
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Type
Calibration
Self-diagnosis
Fuel types
Power supply
Charging time:
Battery life
Printer
Printer power supply
Print capacity
Service and user information
Printed report header
Display
Flue gas probes
Memory
Serial communication
Operating temperature
Storage temperature
Dimensions and Weight
: hand-held combustion gasanalyzer with 2, 3 or 4 gas sensors.
: automatic calibrationprocedure at instrument switch-On.
: Sensors efficiencytest with diagnostic messages.
: Up to 10 selectablefrom keyboard.
: High capacity Ni-MH rechargeable battery pack /external battery charger.
8h at 90% withinstrument Off.
: 6 hours (typical)continuous use (without printingand backlight).
: Internal impact type 24columns with 2.3” paper roll.
: from theanalyzer battery pack.
: up to 40 reportswith battery .
: 3programmable lines.
: 4programmable lines
: 1.6”x2.3” graphic LCD withbacklight device.
: stainless steelshaft with temperaturesensor.
: up to 250 full analysisdata structured by boilers (Tags).
: IR serialport. Optional IR/RS232 serialinterface adapter.
: from 23°Fto 113°F
: from -4°F to+140°F (3 months maximum attemperatures exceeding theoperational limits).
:45”x3.5”x13” - 2.2 lb with batteryand printer
full (typical)
incorporated
DBGas 2004 - Boiler test & Customer database manager
BTU 3000+ can store 250 readingsstructured by boilers and customers.Using the optionalWindows software package, youcan organize and manage yourinspection and maintenanceactivity.
DBGas 2004 software packageincludes Windowssoftware. With this software youcan modify the configuration ofthe instrument.
DBGas2004
GasConfig
TM
TM
Parameter Sensor type Range Resolution Accuracy
O
CO
NO
NO
Tair
Tgas
T
Pressure/Draft
Smoke index
2
2
2
2
flow
return
Electrochemical 0 - 25% 0.1% ±0.1% vol.
Calculated 0 - 5000ppm
Pt100 -10 - 99.9°C 1°C ±(0.2% rdg + 0.15°C)
TC K 0 - 999.9°C
Piezo -10 - ±100hPa 0.01Pa ±3Pa <300Pa
±1%rdg >300Pa
Paper filter method 0-9
Electrochemical 0 - 8000ppm 1ppm ±10ppm <300ppm
±4%rdg up to 2000ppm
±10%rdg >2000ppm
Electrochemical 0 - 20,000ppm 1ppm ±10ppm <300ppm
±4%rdg up to 2000ppm
±10%rdg >2000ppm
Electrochemical 0 - 4000ppm 1ppm ±5ppm <125ppm
±4%rdg up to 4000ppm
Electrochemical 0 - 1000ppm 1ppm ±5ppm <125ppm
±4%rdg up to 1000ppm
Electrochemical 0 - 4000ppm 1ppm ±5ppm <125ppm
±4%rdg up to 4000ppm
Calculated 0 - 99.9% 0.1%
1°C ±(0.3% rdg + 0.3°C)
Calculated 0 - 999°C 0.1°C
TC K -10 - 99.9°C 0.1°C ±(0.3% rdg + 0.3°C)
TC K -10 - 100°C 0.1°C ±(0.3% + 0.3°C)
Calculated 1.00 - infinity 0.01
Calculated 0 - 99.9m/s 0.1m/s
Calculated 1 - 99.9% 0.1%
H <2000ppm comp.
14.0 - 212.0°F 0.2°F
2
CO
NO
SO
CO
T
T
Excess air
Gas speed
Efficiency
X
±(0.2% rdg + 0.3°F)
32.0 - 1830°F 0.2°F ±(0.3% rdg + 0.6°F)
32.0 - 1830°F 0.2°F
14.0 - 212.0°F 0.2°F ±(0.3% rdg + 0.6°F)
14.0 - 212.0°F 0.2°F ±(0.3% rdg + 0.6°F)
∆
!
!
!
!
!
All emissions measurements are available also with a programmable O reference value.
NO concentration can be shown in terms of stack equivalent NO .
Accuracy limits are stated as % of reading. Additional ±1 digit error has to be considered.The pressure accuracy shown is valid only after zero procedure.
2
X 2
Measuring readings can be directly converted from ppm to mg/Nm and from hPa to mbar, mmH O, inH O.3
2 2
BTU 3000+ BTU 3000+
eurotron
UniGas
Innovative Instrumentation Solutions
Multifunction Unit forComplete Maintenanceof your Boiler
The handheldprovides the latest tecnology in fluegas analysis. One instruments withmany features:
NEW BTU 3000+
.
.
.
.
.
.
.
.
up to 4 gas sensors;
CO sensor with manual orautomatic protection;
built-in impact printer;
water, air, surface temperaturemeasurements;
draft, gauge and differentialpressure measurements;
searching for presence andlocation of gas leaks;
operator safety with ambient COcontinuous monitoring;
ambient temperature and relativehumidity measurements.
One Instrument withMany Functions
Easy Replaceable Gas Sensors
CO Sensor Protection
Keyboard & Display
BTU 3000+ uses long life, lowmaintenance sensors. Alarm levelswith audible buzzer on gasmeasurements.
An automatic device can exlude theCO sensor in presence of high COlevel.
Text, menu, and keyboard available inmost common languages (not icons)for simple and intuitive operations.Engineering units are selectable bykeyboard.The large backlight graphic LCD candisplay 3, 6 or 12 values per page(ZOOM function) or with bargraphformat.
Standard Report of Calibration
Rechargeable Battery Operations
Multi Fuel Selection
Each instrument is factory calibratedand certified against E-InstrumentsStandard to ensure traceability, andshipped with a Report of Calibration.
Ni-MH rechargeable batteries providelonger field use. Flue gas analyzerand internal printer is powered by abattery pack. Charger is supplied asstandard.
BTU 3000+ provides up to 10 fuels forcalculating combustion values.
Most used fuels for your country arepre-loaded from factory. Others fuelscan be added using GasConfig PCsoftware.
morereadable, long lasting and heatresistant
as pipework leak withpressure decay programme
An external optional probe isavailable for continuoussurveillance of the ambient and
Built-In Impact Printer
Pressure/Draft input
Smoke Index
Gas Sampling Probe
Combustion Air TemperatureProbe
CO Ambient Monitoring
The instrument has an optional internaland rugged printer. It uses a low costcommon roll of paper. Certainly
than the thermal printout onchemical paper.
Smoke index measurement isperformed by using the optionalexternal hand pump. The results canbe stored in the internal memory andprinted on the report.
Flue gas sampling probes, withdifferent lengths and shapes, areavailable to match each specificrequirement. The sampling probe isconnected to the instrument with asingle or dual hose through a watertrap and a suspended particle filter.
A remote Pt100 probe isavailable for remotecombustion air temperaturemeasurement. This probe isstrongly recommended mainlyin forced air boiler to obtain anaccurate efficiencymeasurement.
Differential pressure input to verify: lowpressure, draft, g
, pressurein gas pipework, pressure in
combustion chamber, P on filters and
fan, pressure switches calibration.
Patent pending to inhibit water into theinstrument. External, to prevent risk ofinstrument damage. Large watertank capacity for condensationboiler. Small rubber cup foreasy water purge. Long lifepaper filter.
∆
Proprietary Design Trap
To check gas pipework for the presenceof leaks using a pressure decay programand the internal pressure sensor.
An external probe is available fortemperature and relative humidity(T+RH%) of the ambient for comfortindex computation.
Gas Leak Snifferexternal
Ionization Flame Tester
Flash Memory
An probe is available to locatethe position of a gas leak. This probehas a flexible stainless steel shaft toreach difficult locations.
Checks the ionization current in flamecontrol sensor.
T+RH Ambient Monitoring
The flash memory allows the instrumentto be configured by updating the UniGasfirmware for any future legislationrequirement or product performanceupgrading.
Providing theProfessional Toolfor Heating Engineers
Specifications
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Type
Calibration
Self-diagnosis
Fuel types
Power supply
Charging time:
Battery life
Printer
Printer power supply
Print capacity
Service and user information
Printed report header
Display
Flue gas probes
Memory
Serial communication
Operating temperature
Storage temperature
Dimensions and Weight
: hand-held combustion gasanalyzer with 2, 3 or 4 gas sensors.
: automatic calibrationprocedure at instrument switch-On.
: Sensors efficiencytest with diagnostic messages.
: Up to 10 selectablefrom keyboard.
: High capacity Ni-MH rechargeable battery pack /external battery charger.
8h at 90% withinstrument Off.
: 6 hours (typical)continuous use (without printingand backlight).
: Internal impact type 24columns with 2.3” paper roll.
: from theanalyzer battery pack.
: up to 40 reportswith battery .
: 3programmable lines.
: 4programmable lines
: 1.6”x2.3” graphic LCD withbacklight device.
: stainless steelshaft with temperaturesensor.
: up to 250 full analysisdata structured by boilers (Tags).
: IR serialport. Optional IR/RS232 serialinterface adapter.
: from 23°Fto 113°F
: from -4°F to+140°F (3 months maximum attemperatures exceeding theoperational limits).
:45”x3.5”x13” - 2.2 lb with batteryand printer
full (typical)
incorporated
DBGas 2004 - Boiler test & Customer database manager
BTU 3000+ can store 250 readingsstructured by boilers and customers.Using the optionalWindows software package, youcan organize and manage yourinspection and maintenanceactivity.
DBGas 2004 software packageincludes Windowssoftware. With this software youcan modify the configuration ofthe instrument.
DBGas2004
GasConfig
TM
TM
Parameter Sensor type Range Resolution Accuracy
O
CO
NO
NO
Tair
Tgas
T
Pressure/Draft
Smoke index
2
2
2
2
flow
return
Electrochemical 0 - 25% 0.1% ±0.1% vol.
Calculated 0 - 5000ppm
Pt100 -10 - 99.9°C 1°C ±(0.2% rdg + 0.15°C)
TC K 0 - 999.9°C
Piezo -10 - ±100hPa 0.01Pa ±3Pa <300Pa
±1%rdg >300Pa
Paper filter method 0-9
Electrochemical 0 - 8000ppm 1ppm ±10ppm <300ppm
±4%rdg up to 2000ppm
±10%rdg >2000ppm
Electrochemical 0 - 20,000ppm 1ppm ±10ppm <300ppm
±4%rdg up to 2000ppm
±10%rdg >2000ppm
Electrochemical 0 - 4000ppm 1ppm ±5ppm <125ppm
±4%rdg up to 4000ppm
Electrochemical 0 - 1000ppm 1ppm ±5ppm <125ppm
±4%rdg up to 1000ppm
Electrochemical 0 - 4000ppm 1ppm ±5ppm <125ppm
±4%rdg up to 4000ppm
Calculated 0 - 99.9% 0.1%
1°C ±(0.3% rdg + 0.3°C)
Calculated 0 - 999°C 0.1°C
TC K -10 - 99.9°C 0.1°C ±(0.3% rdg + 0.3°C)
TC K -10 - 100°C 0.1°C ±(0.3% + 0.3°C)
Calculated 1.00 - infinity 0.01
Calculated 0 - 99.9m/s 0.1m/s
Calculated 1 - 99.9% 0.1%
H <2000ppm comp.
14.0 - 212.0°F 0.2°F
2
CO
NO
SO
CO
T
T
Excess air
Gas speed
Efficiency
X
±(0.2% rdg + 0.3°F)
32.0 - 1830°F 0.2°F ±(0.3% rdg + 0.6°F)
32.0 - 1830°F 0.2°F
14.0 - 212.0°F 0.2°F ±(0.3% rdg + 0.6°F)
14.0 - 212.0°F 0.2°F ±(0.3% rdg + 0.6°F)
∆
!
!
!
!
!
All emissions measurements are available also with a programmable O reference value.
NO concentration can be shown in terms of stack equivalent NO .
Accuracy limits are stated as % of reading. Additional ±1 digit error has to be considered.The pressure accuracy shown is valid only after zero procedure.
2
X 2
Measuring readings can be directly converted from ppm to mg/Nm and from hPa to mbar, mmH O, inH O.3
2 2
BTU 3000+ BTU 3000+
NEW
eurotron
UniGas
BTU 3000+
BTU 3000+
Innovative Instrumentation SolutionsA unit of E instruments Group LLC
eurotron
UniGas
Innovative Instrumentation Solutionswww.einstrumentsgroup.com
E INSTRUMENTS
GROUP LLC
1
3
4
5
6
7
8
2
9
NO
N-C
ON
TR
AC
TD
OC
UM
EN
T-
SU
BJE
CT
TO
CH
AN
GE
E Instruments Group LLC
e-mail: [email protected] UniGas is a member of E Instruments Group LLC
172 Middletown BlvdSuite B 201
Langhorne, PA 19047Tel: 215 750 1212Fax: 215 750 1399
Distributed by:
Bulle
ttin
06-2
2.3
US
-ed.11/2
004
All descriptions are related to a fully optioned instrument. See last page for the different configurations.
Professional Combustion Analyzer
Built-In Impact Printer
Rechargeable Battery
Easy to Use, Text and Keyboard
in any Language
Stores up to 250 Samples
Graphic Display
Upgradable using Flash
Memory
9 INSTRUMENTS IN 1:
Designed to meet BS7927, TUV,
ISO, Gastec QA Criteria, GOST,
Qualigaz, and UNI 10389
Multifunction Unit for the Complete Maintenance of your Boiler
Combustion GasAnalyzer
Draft & DifferentialPressure Meter
2 ChannelThermometer
Ambient CO Monitor
Gas Pipework LeakTester
Gas Leak Detector
Ionization Flame Tester
O2
CO2
CO
Efficiency
Excess Air
DifferentialPressure
TairTgas
CO/CO2
Ratio
Ambient COMonitor
Gas LeakDetector
NO/NO & SO
Emissions AnalyserX 2
NOX
T+RH%Probe
Temperature &Humidity Meter
SO2
F7828000Manual pump for smokeindex measurements
BB830006Pt100 remote air sensorwith cone
BB610051
BB610046
7” (TGD - Temperature, Gas, Draft)sampling probe
12” (TGD - Temperature, Gas,Draft) sampling probe
BB880028
BB880033ABS rigid carrying case
Aluminium carrying case
F2139000Pipe Velcro Tc type K
F21371005” Contact type K Tc
BB830009A COmbient probe
Ambient T+RH% probe
Gas sniffer probe
BB830008
BB830010
BB880043Compact rigid carrying case withshoulder stap. BTU 3000+, probes, andaccessories need 1/3 of the classiccarrying case space.
EE300088Pressure probe andburner hose kit(single hose)
F21321005” air type KTc
BB290040DC Auto Adapter
BB830019Ionization current probe
Accessories Ordering Code
Table A Sensor n.1
Table B Sensor n.2
Table C Sensor n.3 Sensor n.4
Table D Sample probes
Table E Options
Table G Accessories
Table H Report of calibration
1 O (0-25%)
2 CO (0-8000 ppm)2X CO (0-20000 ppm)
0 none4 NO (0-4000 ppm) / NO
5 NO (0-1000 ppm) NO (0-1000 ppm)
6 SO (0-4000 ppm) SO (0-4000 ppm)
(including water trap and line filter)0 none1D 7” flue gas probe + draft (dual hose) BB6100513 12” flue gas probe + draft (dual hose) BB6100465D 29.5” flue gas probe + draft (dual hose) BB6100806 3.5” 90° flue gas or draft (single hose) probe BB6100437 6.3” multipoint flue gas (single hose) probe for
atmospheric boilers BB610070
0 none1 Built-in impact printer3 Gas network leak test procedure with pressure decay
programme4 Graphic display capability (bargraph)6 Electrovalve for automatic/manual CO exlusion
2 230V ±10% 50/60Hz - Schuko plug3 230V ±10% 50/60Hz - UK plug4 230V ±10% 50/60Hz - European plug5 100V ±10% 50/60Hz - USA/Japan plug
0 None1 Software GasConfig + DBGas2000 + IR/RS232 adapter2 Magnetic plate3V Vinyl case with shoulder strap3 ABS carrying case4 Aluminum carrying case5 Remote combustion air temperature sensor with 2m
cable and positionning cone7 Differential pressure connection kit (dual hose)8 External probe for CO operator safety9 External probe for gas leak detectorB Manual pump for smoke index measurement with filters
and comparison tableC External probe for ambient temperature and relative
umidityD External probe for boiler ionization currentE DC Auto battery charger
1 E-Instruments
2
X
2 2
2 2
Table F Mains adapter / charger1 115V ±10% 50/60Hz - USA plug
Modular Design GivingTotal Flexibility
cat. 7823 - A - B - C C - D - E - F - G - H
Low-N
ORe
ady!
x