Asset: BEDFORD ACADEMY - BROOKLYN, 1119 BEDFORD AVENUE, New York, 11216 Inspection Id Inspection Type Time In Last Edited SA : K994 Architectural - Senior 2020-08-06 7:44 AM 2020-09-11 12:06 PM AA : K994 Architectural - Associate 2020-08-06 8:44 AM 2020-08-06 1:25 PM Asset Data Question Answer Was the building fully accessible for inspection Yes Principal(s) Information Principal Name Adofo Muhammad Organization Bedford Academy - Brooklyn Did you meet with this Principal? No Did this Principal provide feedback? Yes Summary of Principal's Feedback A Principal questionnaire form was returned with the following comment. The HVAC system does not properly function. Custodian Was not present Fireman Jerry Jones Building Square Footage 23000 Comments on the Area None Comments on the Stories (Floors) plus Basements 3+B+PH Comments on the Number of Classrooms 12 Comments on the Year Built 1920 Student Population 361 Staff Population 45 Weather Fair Facade Photo Corner of Bedford Avenue and Monroe Street - Northeast View NYC Department of Education Architectural Inspection Building Condition Assessment Survey 2019 - 2020 K994 PB/A&W Print Date: 9/13/2020 Page 1 of 24

Transcript of NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window...

Page 1: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Asset: BEDFORD ACADEMY - BROOKLYN, 1119 BEDFORD AVENUE, New York, 11216

Inspection Id Inspection Type Time In Last Edited

SA : K994 Architectural - Senior 2020-08-06 7:44 AM 2020-09-11 12:06 PM

AA : K994 Architectural - Associate 2020-08-06 8:44 AM 2020-08-06 1:25 PM

Asset Data

Question Answer

Was the building fully accessible for inspection Yes

Principal(s) Information

Principal Name Adofo Muhammad

Organization Bedford Academy - Brooklyn

Did you meet with this Principal? No

Did this Principal provide feedback? Yes

Summary of Principal's Feedback A Principal questionnaire form was returned with the followingcomment. The HVAC system does not properly function.

Custodian Was not present

Fireman Jerry Jones

Building Square Footage 23000

Comments on the Area None

Comments on the Stories (Floors) plus Basements 3+B+PH

Comments on the Number of Classrooms 12

Comments on the Year Built 1920

Student Population 361

Staff Population 45

Weather Fair

Facade Photo

Corner of Bedford Avenue and MonroeStreet - Northeast View

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 1 of 24

Page 2: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Main Entrance Photo

Facade A - Bedford Avenue

Roof Photo

Roof 1 - North View

Have any Systems/Major Building Components been upgraded? Yes

Systems: Limited Parapet repairs

Year: 2017

Systems: Limited Window repairs; limited Ceiling replacement(Rooms 101, 107, 204 and Entrance Lobby)

Year: 2016

Systems: Parapet reconstructed including Coping along BedfordAvenue; Cornice removed

Year: 2014

Systems: Structural crack repairs at Basement

Year: 2010

Systems: Complete Exterior and Interior Modernization andBuilding conversion project including Roof Barriers

Year: 2006

Have there been any New Building Additions? No

Tandem Schools? No

Leased Space? Yes

Year Leased 2005

Inspection Full Inspection

Priority Condition

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 2 of 24

Page 3: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

PriorityCondition ExistLast Year?

PriorityCategory

ConditionDescription

ComponentAffected

LocationDescription

Person(s)Notified

Person(s) Title PhotoImage

No condition recorded

Structural Engineer Required

StructuralCondition Type

ConditionDescription

ComponentAffected

LocationDescription

Person(s)Notified

Person(s) Title PhotoImage

No condition recorded

Accessibility

Accessibility Status Question Response

Is the primary or secondary entrance on an accessible route? Yes

Is the building a multi-story building? Yes

Are all floors of the building accessible through compliant means? Yes

Accessible classrooms exists on each floor? Yes

Boys and Girls or Unisex accessible toilets exist on at least every other floor? Yes

If the following spaces exist, are they ALL accessible? Art Room, Auditorium,Cafeteria, Computer, Gymnasiums, Library, Multipurpose Room, Science Labs

Yes

Physical Breakdown Structure Exists Required Complies Deficiency AudioInductionSystem

FireAlarmStrobe

FUNCTIONAL ACCESSIBILITY

Exterior Routes

Exterior Entrances & Exits Yes

Exterior H/C Lifts No No

Exterior Ramps and Railings Yes Yes

Interior Routes

Corridor and Lobby H/C Lifts No No

Interior Corridor Doors and Hardware No No

Interior Corridors and Lobbies Yes

Interior Elevators Yes Yes

Interior Lobby Doors and Hardware Yes

Interior Ramps No

Rooms & Spaces

Art Rooms No

Auditorium No

Cafeteria Basement Yes Yes Yes Yes

Classrooms 1st - 3rd Floor Yes Yes

Computer Rooms No

Gymnasium No

Library No

Main Office Room 106 Yes Yes

Multi-purpose Room No

Nurse's Room Room C04 Yes Yes

Pool No

Science Lab Room 304 Yes Yes

Toilet Rooms (Boys) Basement and 2nd Floors Yes Yes

Toilet Rooms (Girls) Basement, 1st and 3rd Floors Yes Yes

Toilet Rooms (Staff) Basement and 1st Floors Yes Yes

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 3 of 24

Page 4: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Physical Breakdown Structure Exists Required Complies Deficiency AudioInductionSystem

FireAlarmStrobe

Building Template

Inspection

Question Response

Architectural

EXTERIOR Inspected

AREAWAY Does not Exist

AWNINGS AND CANOPIES Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

CHIMNEY Inspected

Material Type(s) Metal

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

COPING Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

CORNICE Does not Exist

DOORS Inspected

DOORS AND FRAMES Inspected

Condition 5 - Poor

Deficiency METAL: DETERIORATED DOOR AND FRAME - MAJORDETERIORATION

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 4 of 24

Page 5: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

DOORS

DOORS AND FRAMES

Roof Plan reference

Deficiency Quantity 1

Quantity Uom EACH

Potential Action REPLACE

Urgency of Action PRIORITY 4

Purpose of Action LEVEL 2

Deficiency Photo1

Facade A - Exit 2

Violations No violations recorded.

DOOR HARDWARE Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

LINTELS Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

TRANSOM/SIDE LIGHT Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

EXTERIOR WALLS Inspected

Material Type(s) Masonry, Steel

Replacement Quantity 8,000

Replacement Uom S.F.

InspectedInstance on Facades A, C - F

Instance Condition 3 - Fair

Instance Quantity 8,000

Instance Quantity Uom S.F.

Deficiency BRICK: OPEN JOINTS

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 5 of 24

Page 6: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

EXTERIOR WALLS

Roof Plan reference

Elevation

Deficiency Quantity 30

Quantity Uom S.F.

Potential Action REPOINT

Urgency of Action PRIORITY 4

Purpose of Action LEVEL 2

Deficiency Photo1

Facade A

Violations No violations recorded.

Deficiency BRICK: MAJOR / THRU CRACKS

Roof Plan reference

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 6 of 24

Page 7: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

EXTERIOR WALLS

Elevation

Deficiency Quantity 10

Quantity Uom S.F.

Potential Action REMOVE AND REBUILD

Urgency of Action PRIORITY 4

Purpose of Action LEVEL 2

Deficiency Photo1

Facade A

Violations No violations recorded.

Deficiency BRICK: OPEN JOINTS

Roof Plan reference

Elevation

Deficiency Quantity 400

Quantity Uom S.F.

Potential Action REPOINT

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 7 of 24

Page 8: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

EXTERIOR WALLS

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Facade A

Violations No violations recorded.

EXTERIOR SOFFITS Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

LOADING DOCK Does not Exist

LOUVER Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

PARAPETS Inspected

Material Type(s) Masonry, Metal

Replacement Quantity 3,000

Replacement Uom C.F.

InspectedInstance on All Facades

Instance Condition 3 - Fair

Instance Quantity 3,000

Instance Quantity Uom C.F.

Deficiency BRICK: MINOR CRACKS, SPALLING

Roof Plan reference

Deficiency Quantity 20

Quantity Uom S.F.

Potential Action REPAIR

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 8 of 24

Page 9: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

PARAPETS

Deficiency Photo1

Facade A - Roof 1

Violations No violations recorded.

Deficiency BRICK: EFFLORESCENCE

Roof Plan reference

Deficiency Quantity 40

Quantity Uom S.F.

Potential Action MAINTENANCE

Urgency of Action PRIORITY 1

Purpose of Action LEVEL 1

Deficiency Photo1

Facade A - Roof 1

Violations No violations recorded.

PLAZA DECK Does not Exist

ROOF Inspected

Roofing Inspected

Replacement Quantity 8,000

Replacement Uom S.F.

ROOF HATCH/SMOKE HATCH Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS Inspected

Condition 2 - Between Good and Fair

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 9 of 24

Page 10: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

ROOF

Roofing

LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS Inspected

Deficiency No deficiencies recorded

ROOF BARRIER Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

ROOF CAGE Does not Exist

ROOF FENCE Does not Exist

ROOFING Inspected

InspectedInstance on IRMA: All Roofs

Instance Condition 4 - Between Fair and Poor

Instance Quantity 8,000

Instance Quantity Uom S.F.

Does the roof have major mechanical equipment sitting onDunnage Steel less than 18" above the Roofing?

No

Installation Year 2005

Source of Installation Custodial Staff

Deficiency IRMA: ROOFING: LOSS OF GRAVEL

Roof Plan reference

Deficiency Quantity 40

Quantity Uom S.F.

Potential Action MAINTENANCE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Roof 1

Violations No violations recorded.

Deficiency IRMA: ROOFING: DAMAGED INSULATION

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 10 of 24

Page 11: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

ROOF

Roofing

ROOFING

Roof Plan reference

Deficiency Quantity 30

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 4

Purpose of Action LEVEL 2

Deficiency Photo1

Roof 1

Violations No violations recorded.

Deficiency IRMA: ROOFING: MAJOR ACTIVE ROOF LEAKS ININSTRUCTIONAL SPACE

Roof Plan reference

Deficiency Quantity 200

Quantity Uom S.F.

Potential Action REPLACE ROOFING WITHOUT MAJOR EQUIPMENTREMOVAL

Urgency of Action PRIORITY 5

Purpose of Action LEVEL 2

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 11 of 24

Page 12: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

ROOF

Roofing

ROOFING

Deficiency Photo1

Roof 1 - Room 305 shown, Roof 1 - Room 304 similar

Violations No violations recorded.

ROOFING DRAINS Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Specialties Inspected

BULKHEAD/PENTHOUSE Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

CUPOLA/ SPIRES/ TOWERS Does not Exist

DORMER Does not Exist

DUNNAGE STEEL Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

SKYLIGHT/ROOF VENT Does not Exist

ROOF/GRAVITY TANK Does not Exist

STAIRS/RAMPS: EXTERIOR Inspected

BUILDING CHEEK/FLANK WALLS Does not Exist

RAILINGS Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

STAIRS/RAMPS Inspected

Condition 3 - Fair

Deficiency CONCRETE: CRACKS/SPALLING - MAJOR

Roof Plan reference

Deficiency Quantity 10

Quantity Uom S.F.

Potential Action REPLACE

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 12 of 24

Page 13: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

STAIRS/RAMPS: EXTERIOR

STAIRS/RAMPS

Urgency of Action PRIORITY 4

Purpose of Action LEVEL 2

Deficiency Photo1

Facade A - Main Entrance

Violations No violations recorded.

WINDOWS Inspected

Replacement Quantity 4,000

Replacement Uom S.F.

EXTERIOR GUARDS Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

LINTELS Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

WINDOWS Inspected

Material Type(s) Aluminum

InspectedInstance on Aluminum - Other: Facades A, C, E

Instance Condition 3 - Fair

Instance Quantity 4,000

Instance Quantity Uom S.F.

Installation Year 2005

Source of Installation Custodial Staff

Deficiency ALUMINUM - OTHER: BROKEN PANE

Roof Plan reference

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 13 of 24

Page 14: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

EXTERIOR

WINDOWS

WINDOWS

Elevation

Deficiency Quantity 160

Quantity Uom S.F.

Potential Action MAINTENANCE

Urgency of Action PRIORITY 5

Purpose of Action LEVEL 2

Deficiency Photo1

Facade A - Room 305 shown, Facade A - Room 304 similar

Violations No violations recorded.

INTERIOR Inspected

POOLS Does not Exist

STRUCTURAL Inspected

COLUMNS/BEAMS/BEARING WALLS Inspected

Condition 3 - Fair

Deficiency STEEL COLUMNS/BEAMS: DETERIORATED CONCRETEFIREPROOFING

Deficiency Location/Instance Basement - Boiler Room

Deficiency Quantity 10

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 4

Purpose of Action LEVEL 5

Deficiency Photo1

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 14 of 24

Page 15: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

STRUCTURAL

COLUMNS/BEAMS/BEARING WALLS Inspected

Basement - Boiler Room

Violations No violations recorded.

FLOOR STRUCTURE Inspected

Condition 3 - Fair

Deficiency CONCRETE SLAB ON GRADE: MINOR CRACKS

Deficiency Location/Instance Basement - Boiler Room

Deficiency Quantity 20

Quantity Uom S.F.

Potential Action REPAIR

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 5

Deficiency Photo1

Basement - Boiler Room

Violations No violations recorded.

Deficiency CONCRETE: CRACKS/SPALLED/REINFORCEMENT EXPOSED

Deficiency Location/Instance Basement - Boiler Room, Electric Service Room C10A, WaterSprinkler Room C10C

Deficiency Quantity 50

Quantity Uom S.F.

Potential Action REPAIR

Urgency of Action PRIORITY 4

Purpose of Action LEVEL 5

Deficiency Photo1

Basement - Boiler Room

Violations No violations recorded.

FOUNDATION WALLS Inspected

Material Type(s) Concrete

Condition 3 - Fair

Deficiency CONCRETE: CRACKED/SPALLED/REINFORCEMENTEXPOSED

Deficiency Location/Instance Basement - Boiler Room

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 15 of 24

Page 16: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

STRUCTURAL

FOUNDATION WALLS

Deficiency Quantity 80

Quantity Uom S.F.

Potential Action REPAIR

Urgency of Action PRIORITY 4

Purpose of Action LEVEL 5

Deficiency Photo1

Basement - Boiler Room

Violations No violations recorded.

ROOF STRUCTURE Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

VAULTS-BUNKERS Does not Exist

AUDITORIUM Does not Exist

CAFETERIA Inspected

InspectedInstance on Basement (600 SF)

Ceiling

InspectedInstance on Basement (600 SF)

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Door(s)

InspectedInstance on Basement (600 SF)

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Fixed Equipment

Does not ExistInstance on Basement (600 SF)

Floor Finish

InspectedInstance on Basement (600 SF)

Condition 5 - Poor

Deficiency VINYL TILES: BROKEN/DETERIORATED/MISSING TILES

Deficiency Location/Instance Center

Deficiency Quantity 60

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 16 of 24

Page 17: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

CAFETERIA

Floor Finish

Deficiency Photo1

Center

Violations No violations recorded.

Deficiency VINYL TILES: DETERIORATED SUBSTRATE

Deficiency Location/Instance Near Entrance

Deficiency Quantity 25

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Near Entrance

Violations No violations recorded.

Sliding-folding Partition

Does not ExistInstance on Basement (600 SF)

Stage

Does not ExistInstance on Basement (600 SF)

Walls

InspectedInstance on Basement (600 SF)

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Window Curtains/Shades/Blinds

Does not ExistInstance on Basement (600 SF)

CLASSROOMS/CORRIDORS/ADMIN SPACES Inspected

Ceiling Inspected

Condition 2 - Between Good and Fair

Deficiency PLASTER: CRACKS/SPALLING - ACTIVE LEAK

Deficiency Location/Instance Rooms 304, 305

Deficiency Quantity 50

Quantity Uom S.F.

Potential Action REPLACE

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 17 of 24

Page 18: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

CLASSROOMS/CORRIDORS/ADMIN SPACES

Ceiling

Urgency of Action PRIORITY 5

Purpose of Action LEVEL 2

Deficiency Photo1

Room 304

Violations No violations recorded.

Deficiency GYPSUM BOARD: DAMAGED/DETERIORATED

Deficiency Location/Instance Corridor near Room 106, 104A

Deficiency Quantity 15

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Corridor near Room 106

Violations No violations recorded.

Deficiency PLASTER: CRACKS/SPALLING

Deficiency Location/Instance Room 302A

Deficiency Quantity 10

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 18 of 24

Page 19: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

CLASSROOMS/CORRIDORS/ADMIN SPACES

Ceiling Inspected

Room 302A

Violations No violations recorded.

Door(s) Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Floor Finish Inspected

Condition 2 - Between Good and Fair

Deficiency VINYL TILES: DETERIORATED SUBSTRATE

Deficiency Location/Instance Main Entrance Lobby, Corridor near Room C10C, C01

Deficiency Quantity 30

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Main Entrance Lobby

Violations No violations recorded.

Walls Inspected

Condition 2 - Between Good and Fair

Deficiency GYPSUM BOARD: DETERIORATED

Deficiency Location/Instance Corridor near Room 302A, 106, 104A, 103, 102, C10C

Deficiency Quantity 50

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Corridor near Room 103

Violations No violations recorded.

Specialties Inspected

Classroom Locker(s) Inspected

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 19 of 24

Page 20: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

CLASSROOMS/CORRIDORS/ADMIN SPACES Inspected

Specialties

Classroom Locker(s) Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Fixed Seating Does not Exist

GYMNASIUM Does not Exist

INTERIOR DOOR HARDWARE Inspected

Condition 3 - Fair

Deficiency No deficiencies recorded

INTERIOR GUARDS Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

KITCHEN Inspected

InspectedInstance on Basement

Ceiling

InspectedInstance on Basement

Condition 2 - Between Good and Fair

Deficiency METAL PAN: DAMAGED/MISSING

Deficiency Location/Instance Servery, Back of the Room

Deficiency Quantity 10

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Servery

Violations No violations recorded.

Door(s)

InspectedInstance on Basement

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Floor Finish

InspectedInstance on Basement

Condition 2 - Between Good and Fair

Deficiency QUARRY TILE: BROKEN/MISSING TILES

Deficiency Location/Instance Near stove

Deficiency Quantity 10

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 20 of 24

Page 21: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

KITCHEN

Floor Finish

Purpose of Action LEVEL 2

Deficiency Photo1

Near stove

Violations No violations recorded.

Walls

InspectedInstance on Basement

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

LIBRARY Does not Exist

LOCKER ROOM Does not Exist

MULTI-PURPOSE ROOM Does not Exist

SCIENCE DEMO ROOM Does not Exist

SCIENCE LAB Inspected

InspectedInstance on Room 304

Alternative use No

Fixed Equipment

InspectedInstance on Room 304

Condition 5 - Poor

Deficiency CABINETRY: MISSING/DAMAGED

Deficiency Location/Instance Room 304

Deficiency Quantity 40

Quantity Uom L.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Room 304

Violations No violations recorded.

SCIENCE PREP ROOM Does not Exist

SHOWER ROOM Does not Exist

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 21 of 24

Page 22: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

STAIRS/RAMPS: INTERIOR Inspected

Do Letter Stair Signs Exist? Yes

Ceiling Does not Exist

Door(s) Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Partition Does not Exist

Railings Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Stairs and Landings Inspected

Condition 2 - Between Good and Fair

Deficiency CONCRETE: CRACKS/SPALLING - MAJOR

Deficiency Location/Instance Stair B/Basement

Deficiency Quantity 10

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Stair B/Basement

Violations No violations recorded.

Walls Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

TOILET ROOMS - STAFF Inspected

Ceiling Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Door(s) Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Floor Finish Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Stalls Does not Exist

Walls Inspected

Condition 2 - Between Good and Fair

Deficiency GYPSUM BOARD: DETERIORATED

Deficiency Location/Instance Rooms C10D, C10,E, Kitchen

Deficiency Quantity 15

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 22 of 24

Page 23: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

INTERIOR

TOILET ROOMS - STAFF

Walls

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Room C10D

Violations No violations recorded.

TOILET ROOMS - STUDENTS Inspected

Ceiling Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Door(s) Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Floor Finish Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Stalls Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Walls Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

LIFE SAFETY Inspected

F.D. HOLDING AREA Does not Exist

STEEL STAIRS Does not Exist

SITE Inspected

CONTAINERIZATION Does not Exist

Drainage System for Asphalt Does not Exist

Drainage System for Concrete Does not Exist

Drainage System for Soil Does not Exist

DRINKING FOUNTAINS Does not Exist

FENCES Does not Exist

IRRIGATION SYSTEM Does not Exist

PAVING Inspected

Student Non-Use Does not Exist

Student Use Does not Exist

Site Sidewalks & Walkways Inspected

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 23 of 24

Page 24: NYC Department of Education · Systems: Limited Parapet Repairs Year: 2017 Systems: Limited Window Repairs; limited Ceiling Replacement (Rooms 101, 107, 204, and Entrance Lobby) Year:

Question Response

SITE

PAVING

Site Sidewalks & Walkways

Asphalt Does not Exist

Concrete Inspected

Condition 2 - Between Good and Fair

Deficiency No deficiencies recorded

Pavers Does not Exist

DOT Sidewalk Inspected

Asphalt Does not Exist

Concrete Inspected

Condition 3 - Fair

Deficiency DAMAGED/DETERIORATED/MISSING SECTIONS

Deficiency Location/Instance Bedford Avenue

Deficiency Quantity 50

Quantity Uom S.F.

Potential Action REPLACE

Urgency of Action PRIORITY 3

Purpose of Action LEVEL 2

Deficiency Photo1

Bedford Avenue

Violations No violations recorded.

Pavers Does not Exist

PLAYGROUNDS Does not Exist

PLAYING SURFACE Does not Exist

RETAINING WALLS Does not Exist

SEATING Does not Exist

SITE WALLS (NOT RETAINING WALLS) Does not Exist

STAIRS/RAMPS: EXTERIOR Does not Exist

NYC Department of Education

Architectural Inspection

Building Condition Assessment Survey 2019 - 2020

K994

PB/A&W Print Date: 9/13/2020Page 24 of 24