Numerical Assessment of the Thermal Performance of Structural Precast PanelsStructural Precast Panels
J Keenahan, K Concannon, D Hajializadeh & C McNallyUCD School of Civil, Structural &UCD School of Civil, Structural &Environmental EngineeringEmail: [email protected]
![Page 2: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/2.jpg)
Description
� Precast sandwich panels – widely used panels – widely used in building facades
� 3 layers
o Concrete
o Insulation
o Concreteo Concrete
![Page 3: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/3.jpg)
Industrial Relevance
� New building regulations will specify a much lower U-value for sandwich panelslower U-value for sandwich panels
� Expected to go from 0.25 to 0.15 W/m2K
� Significant implications for industry
� Concern over structural connectors
![Page 4: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/4.jpg)
Structural Connectors
� Needed for all panels
� Traditionally made of steel
� Also available in FRP
� Potential thermal weakness
![Page 5: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/5.jpg)
Structural Connectors
� FRP more expensive, but will they give the required U-value?required U-value?
� 3 panel types studied
� Determined using
• Numerical methods (ASHRAE)U = 1
RA∑• Hot-box testing (Experimental)
• FEA analysis U =
&Q∆T
RA∑
![Page 6: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/6.jpg)
Numerical Analysis
� ASHRAE: American Society for Heating, Refrigeration and Air-Conditioning EngineersRefrigeration and Air-Conditioning Engineers
� U-value: inverse of the resistances of a material
� Theoretical approach
� Thermal resistances electric resistances
o Parallel
o Series
o Combination
![Page 7: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/7.jpg)
Numerical Analysis
![Page 8: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/8.jpg)
Hot-box Testing
� Build insulated room around a series of precast concrete sandwich panelsconcrete sandwich panels
� Install heater inside the room
o Thermostat to control temperature
� Sensors to measure temperature (internal & external) and heat flux
� Monitor using thermal imaging camera� Monitor using thermal imaging camera
� 30˚C Temperature gradient
� Tests duration: 48 hours
� EN 1946-4 (2000)
![Page 9: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/9.jpg)
Hot-box Testing
Materials used:
� Insulation (120 mm)
� FRP connectors (9)
� Steel connectors (3)
![Page 10: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/10.jpg)
Hot-box Testing
Thermal Imaging
![Page 11: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/11.jpg)
FE Analysis
� Conducted using MSC Patran
� 3-D FE solid model (hex elements)
� 2 DOF per node (Temp & heat flux)
� Boundary conditions to mirror hot-box testing
o Internal temp 40˚C
o External temp 10˚Co External temp 10˚C
o Internal convection coefficient 8.29 W/m2K
o External convection coefficient 34 W/m2K
� Patran Connector function
� Transient analysis
![Page 12: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/12.jpg)
FE Analysis
Sample results: steel connectors
![Page 13: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/13.jpg)
FE Analysis
Sample results: FRP connectors
![Page 14: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/14.jpg)
Results
U-Values (W/m2K)
Connector Type
ASHRAE Hot-box FEA
Steel 0.288 0.260 0.286
FRP 0.169 0.150 0.149FRP 0.169 0.150 0.149
Control 0.168 0.139 0.145
![Page 15: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/15.jpg)
Conclusions
� Choice of connectors has a very significant impact on achievable U-valueson achievable U-values
� Simple numerical analysis surprisingly good, but insufficient for low U-values
� FEA verified as offering significant benefits in product development of such panels
![Page 16: Numerical Assessment of the Thermal Performance …...Numerical Assessment of the Thermal Performance of Structural Precast Panels J Keenahan, K Concannon, D Hajializadeh & C McNally](https://reader030.fdocuments.us/reader030/viewer/2022041111/5f10ac4e7e708231d44a42ae/html5/thumbnails/16.jpg)
Acknowledgement
Ergon Structural Concrete
This research is funded by the TEAM project, a Marie Curie Initial Training Network under the EC 7th Framework Programme (PITN-GA-2009-238648)