NUCLEONIX SYSTEMS PRIVATE LIMITED Plot No: 162A&B, PHASEII, I.D.A.Cherlapally, Hyderabad-500051, INDIA
Phone: +91-40-27263701, 040-27262146, 040-68888777, Fax: 040 – 27262146 Mobile No: 7331104480, 7331104481, E-mail: [email protected]
PRE-AMPLIFIER PA320
NUCLEONIX
SYSTEM
S PVT.
LTD
CONTENTS
CHAPTER I
CHAPTER II
CHAPTER III
CHAPTERIV
CHAPTER V
CHAPTER VI
UNPACKING
INTRODUCTION
SPECIFICATIONS
INSTALLATION
BLOCK DIAGRAM & ITS DESCRIPTION
CHARGES SENSITIVE PRE-AMPLIFIER LEGEND PRINT
CONTACT US FOR AVAILING SERVICES
NUCLEONIX
SYSTEM
S PVT.
LTDUNPACKING
Charge sensitive Pre-amplifier Type : PA320 has been thoroughly tested and is despatched in
ready to use condition. However, on unpacking and prior to operation, it is advisable to check
visually and make sure that there is no visible damage caused in transit.
If any damage to the instrument is observed, do not switch ON the unit and report the matter
immediately to :
Customer Support Division Nucleonix Systems
Private Limited Plot No : 162 A & B, PHASE II,
I.D.A.Cherlapally,
Hyderabad - 500 051.
Phone: +91-40-27263701, 040-27262146, 040-68888777, Fax: 040 – 27262146Mobile No: 7331104480, 7331104481,
7331104482, E-mail: [email protected]
In all correspondance regarding the instrument, please mention the type, serial number of the unit, date of supply etc., of the unit.
o FEATURES
Compact solid state circuit design Suitable for wide range of x-ray Proportional and gas flow type of
detectors.
Rise time 100 nano sec.
It is a charge sensitive pre-amplifier uses N-channel FET, in the inputwith charge collection capacitor in the feedback of the operationalamplifier.
CHAPTER - I
INTRODUCTIONCharge sensitive Pre-amplifier PA320 is designed for use with gas filled proportional detectors, X-ray proportional detectors, BF-3 & He3 neutron detectors etc. Users will have the choice to change the load resistors & charge sensitive feedback capacitor according to the gain & sensitivity requirement for a specific application. Charge sensitive pre amplifier consists of an operational amplifier with capacitive feedback & uses an N-FET in the input stage. Output driver transistor is capable of driving a 100 ohms impedance coaxial cable.
Detector output is also brought out from the second stage, for using it for data acquisition purpose. This unit is provided with built in comparator with threshold adjustment to give TTL output for counting applications.
NUCLEONIX
SYSTEM
S PVT.
LTD
: 10 M Ohms
: 100 Ohms
: 1000mv / pico coulombs for first stage. Followed by additional voltage gain stage.
: Better than 100 nano seconds.
: 20 micro sec. (approx).
: Operational amplifier with FET in the front end.
Detector Load Resistor
Output impedance
Charge Sensitivity
Rise Time
Decay Time Constant
Charge Sensitive Device
Power Supply Inputs
Output(s) available:
Dimensions :
: +12V@ 20mA -12V@ 10mA
CHAPTER - II
SPECIFICATIONS
:(a) Linear signal (amplified detector output)(b) TTL output (after comparator
: 155mm L X 95mmW X 50mmH.
CHAPTER - III
INSTALLATION
A. CONTROLS / CONNECTORS:
EHT (MHV socket) : High Voltage connector, at which the EHT supply is provided
to connect to the X-ray proportional counter / gas proportional
/ He-3 / BF3 / Neutron detector for detector biasing.
Output (Linear) : BNC Co-axial connector at which output from the Pre-
Amplifieris generated for connecting to shaping amplifier.
Output (TTL) : This is a TTL output after discriminator provided to cut-off noise.
LV (socket) : Five pin circular connector at which the LV supply voltages
are provided from the NIM Standard instrumentation bin & power
supply unit. Power up the PA320 is fed.
Detector (MHV socket) : MHV connector, to which detector is connected preferably
through a short RG 59 cable. Cable end has to match with
the appropriate connector on the detector.
B. EXTERNAL CONNECTIONS:
Having connected the Pre-amplifier to the detector as explained earlier, proceed to make
the connection as follows:
1. Using the HV cable (MHV to MHV) connect the OUTPUT from High Voltage Unit, type
HV502 /HV503 of NUCLEONIX make or its equivalent to the HV connector (MHV
socket) on PA320.
2. Using Co-axial signal cable connect from the OUTPUT BNC connector on PA320 to the
INPUT of any Pulse shaping Amplifier typically LA520 or AF521or Spectroscopy amplifier.
3. Using LV - I/O, 5 core cable connect to the "LV" connector on PA320 to the LV connector
on Instrumentation bin & power supply. If your instrumentation bin has a 9-pin D-connector,
then you wire up one end with 9 pin D-connector & the other end with 5 pin I/O connector
to mate with corresponding connector on pre-amplifier.
CHAPTER – IV
BLOCK DIAGRAM & ITS DESCRIPTION
C1
Cc
R1
HV
1M 0.01/22KV
0.001/2KV
10M To Detector
anode
C7 RL
Non Inv gain stage
OUTPUT
MHV socket
MHV socket
FET input
TTL
R6
Op amp
Driver
+
P1
20K
+ -
-
Charge Integrator PZ circuit
Op amp
Op amp
Mono
Comparator Mono
OUTPUT
LINEAR
Block diagram of Charge sensitive pre amplifier of PA320 of Nucleonix make
Block diagram description: It can be seen from the block diagram, HV input to the detector is filtered further by an RC filter of R1 (1meg ohm) & capacitor C1 (0.01uf, 2KV). Detector such as an X-ray proportional detector, gas proportional detector or a Neutron detector BF3 or HE-3 IS connected at the MHV /SHV socket provided on the pre amp unit, thru appropriate co-axial cable. Signal from this is ac coupled & applied to the gate input of FET. Followed by this is a charge integrating op.amp with a feedback capacitor of 1pf which integrates the charge collated to give voltage pulse output. Followed by charge integrator output, there is a transistor driver, PZ- circuit and a non inverting op.amp stage, which provides further voltage gain required.
Trimpot (P1) on second stage op.amp can be used to adjust gain.Signal from the output of this second stage is fed to a comparator which helps in cutting of any noise signal. Output of this comparator is fed to a mono stable to get a fixed width TTL output signal. Both Linear output from the second stage & TTL outputs have been brought out for external use & processing or further amplification & acquisition.
Rl4.
HV TPI
SIZE,55Xll9mm CHARGE SENSITIVE PRE A�LIFIER 07 /05/2016 NSPL_PCB_0542
CHARGE SENSITIVE PRE A�LIFIER
(:)
+ 8 TPS AEGI CJS
w
e R2 R3 RI � Rl3�
CS Cl+ • •1
:{J
O �
Cl9 CIB e0
[;J•l2V
0
• o· Ul·
o· re\ ·R�
w
· +eel4 •• �i
i;e
o
.
[;;]
2 : :65
: ���V e e � �o ff P3 u4 -o - e
• • • �
+ CB • . TP4 .P3: : e •• 3 T.PB 191�/
• • • e • • n O - -e • I JPI �
1� --:=i Q2 • •
Cl0�+�+:;___;:e U3 ;0 =• TP7 •
i.:j "'';� .,1 .. ,1 .. :�: .. "'� l!ln"J: �mo[;];, !�� CZ R4 o· �-, ... �o:o: rJElll���or::�r �]":(a\ e 1 � CII G •• 3 (a\ � ··-9· . C3 • • u:-�� uPI
Cl2 P7 2 �
NOTE (1): Pl. C7 are indicated in dashed lines
NOTE (2): To Change charge sensitivity gain,One has to change capacitor (C7) value. By default it is 1pf. One can increase it to 2.2pf or 3.3pf etc. Increasing the value decrease inversely charge sensitivity.
NOTE (3):Further Signal Voltage can be manipulated by P1 – trimpot which is in the op.amp (U2) feedback. Manipulation of P1 alters gain in the second stage.
Chapter VCHARGES SENSITIVE PRE-AMPLIFIER LEGEND PRINT
CHAPTER –VI
CONTACT US FOR AVAILING SERVICES
Postal/Mailing Address (Phone / Fax / Email)
Nucleonix Systems Pvt Ltd.
Plot No. 162 A&B, Phase II, I.D.A.,
Cherlapally, Hyderabad - 500 051, Telangana, India.
Phone: + 91-40-27263701, 040-27262146, 68888777
Mobile: 7331104480, 7331104481, 7331104482
Fax : + 91-40 - 27262146
Email : [email protected]
For any information, Contact by email is always appreciated.
(This will help us to respond to you quickly)
Marketing Department :
a) Sales / Commercial Information / Field installation and servicing
For any Commercial, Price information, Product information, customer coordination &
quotation
of our products customer related commercial services, please contact front office marketing
staff through the listed Email Ids or Phone Nos. given below
Whom to Contact:
1. R.Maniram(Sr. Business Executive)
2. Ch.Gayatri(Business Executive)
3. K.Sarika(Business Executive)
Mob:7331104481, Ph-040-27263701
Mob:7331104481, Ph-040-27263701
Mob:7331104481, Ph-040-27263701
Contact NumbersBusiness Executives: Contac t by E-mail ID
Note: Our business executives will also connect you to concerned Engineer or General Manager
for any technical clarifications if required
b) Factory Services
For Servicing and Calibration factory services & follow up on the above jobs including dispatch
related/payment related issues of serviced & calibrated items please contact
Ms.B.Sravani (Executive services)
Mob:7331104482 E-mail: [email protected]
She will also connect you to concerned engineer or general manager if required, for any clarifications & deficiencies in services
c) Dispatch Related Issues (Production Items)
For dispatch related issues of your ordered equipments, including delays, purchase order
related document deficiencies, payment proofs, dispatch docket details and bills
etc,.contact
Ms.V.Anusha / Renuka Devi (Executive Dispatch)
Ph:040-27263701, Ex-26 E-mail: [email protected]
d) Product Technical Information / Clarifications
Whom To Contact:
Contact any front office "Business Executive"- He/She will take your details and connect you to concerned product engineer for any technical clarifications. Best thing is to email your technical queries and obtain the reply, rather than on telephone.
You can also contact General Manager or Director (Tech) if required.
e) Marketing ManagerOn business matters for all your marketing services / techno commercial requirements aboutNucleonix Products contact:
Bhaskara I.V. Mob:8019662500 Land lines : 91-40-27263701, 91-40-68888777 Email: [email protected]
f) General ManagerDr.M.S.R.Murthy PhD (Nuclear physics)Land line: 91-40-27263701, 91-40-68888777Email: [email protected]
Contact General Manager for all sales / servicing and technical information including customer support related issues, on the delays, gaps & lapses by our staff. Contact G.M. regarding field installations & field servicing jobs schedule etc.
g) H.R -Incharge
Contact her regarding, job vacancies, sending resume for employment, H.R. related issues etc. contact
Ms. M.Swarna Jyothi Mob:7331104480 Email: [email protected]
h) Director -Technical
Mr. J. Dheeraj Reddy
Email: [email protected]
Mobile No. +91-7674009005
Contact him for, any Technical Information and clarifications on products, which cannot be
answered by General Manager / Customer support executives.
For any technical deficiencies in products, related issues & suggestions on product
improvements you may contact by email or telephone. This will help the company to improve
the product & serve you better.
Dealer’s complaints, on commercials, lapses by our commercial staff, or any other discripancy,
or you like to give any feedback on any Nucleonix staff doing any wrong thing against
cleaner / ethical business principles / practices can be complained to any of the directors or
managing director.
i) Director - ITMr. J. Nishanth Reddy
Email: [email protected]; [email protected] No. +91-9966691000
For any deficiencies in product software’s, related issues, & any suggestions or
improvisations in software’s can be contact by email or telephone. This will help the company
to improve the product & serve you better.
j) Managing Director
Shri. J.Narender Reddy (Managing Director)
Email : [email protected]; [email protected]
Contact Managing Director for, Foreign relations, International Business co-operation, Joint
ventures, Exports, Dealership in other countries, Policy matters, Technology tie-ups etc.
k) Dealers Complaints :
Dealers complaints, on commercials, lapses by our commercial staff, or any other discripancy,
or you like to give any feedback on any Nucleonix staff doing any wrong thing against
cleaner /ethical business principles / practices can be complained to any of the directors or
managing director.