Design and Study of a LOX/GH2 Throttleable Swirl Injector ...
Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power...
Transcript of Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power...
![Page 1: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/1.jpg)
Nuclear Thermal Rocket Element Environmental
Simulator (NTREES)
SNSF 2009 Meeting
Marshall Space Flight Center
Michael Schoenfeld
![Page 2: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/2.jpg)
• Need
• Capability
• Experiment Configuration
• Summary
Content
![Page 3: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/3.jpg)
Purpose
– fuel materials that can withstand hot hydrogen is key for NTR.
– NTREES enables: • cost effective & rapid
screening of candidate material
• examining thermal hydraulic performance.
![Page 4: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/4.jpg)
Design Requirements
• Fuel elements environment– Maximum temperature: 3000 K using non-contact Radio Frequency (RF)
power system– Pressure: 1,000 psi to simulate NTR chamber pressure– GH2 flow: up to 0.0011 lb/sec
• Test Sample Materials (surrogates and DU)– Composite graphite (U, Zr)C with ZrC coatings– Advanced CERMET W-Re/UN without coatings
INL CERMETAlabama A&MGlossy Carbon
![Page 5: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/5.jpg)
NTREES Layout
GH2 Trailer
GH2 IsolationValve
CTRL Computer
Vent line
RF PowerSupply
Exhaust, Mixer, HX, Filter
GH2 Control Manifold
Hydrogen supply
Exhaust VPV
DAQ & Control Cabinet
NTRFEESTest Chamber
RF HX
Valve Control CabinetGN2
Manifold
Cooling water
![Page 6: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/6.jpg)
Data Acquisition and Control SystemSchematic
![Page 7: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/7.jpg)
NTREES System Schematic
• 50 kW RF power supply (up to 5 MW available)• Exhaust mixer system and heat exchanger to cool and dilute hot hydrogen flow• Mass spectrometer on vent when testing DU samples• Pyrometers to measure test specimen surface temperatures & axial profile
![Page 8: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/8.jpg)
Coil Assembly
H2 Inlet
H2 / N2 Mixer
NTREES Setup
![Page 9: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/9.jpg)
NTREES Setup
![Page 10: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/10.jpg)
NTREES Setup
Hydrogen Panel
Vent Line
N2 Purge Panel
Water RecirculationSystem
MassSpectrometer
H2 / N2
Mixer
Heat Exchanger(dummy)
Pit
PressureVessel
![Page 11: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/11.jpg)
NTREES Setup
Hydrogen InletPanel for Trailer
Exhaust VentNTREESFacility
![Page 12: Nuclear Thermal Rocket Element Environmental Simulator ...Valve CTRL Computer Vent line RF Power Supply Exhaust, Mixer, HX, Filter GH2 Control Manifold Hydrogen supply Exhaust VPV](https://reader035.fdocuments.us/reader035/viewer/2022071419/6117b25ab27a3c69047b8b86/html5/thumbnails/12.jpg)
Summary
• NTREES provides testing capability to simulate NTR environment (w/o radiation) & is operationally ready to begin testing.
• Enables cost effective & rapid testing for NTP
– candidate fuel screening (hot hydrogen corrosion)
– quantitative thermal hydraulic testing
• Experiment configuration
– Water cooled ASME vessel
– RF heated test piece which can contain surrogate or DU material
– GH2 up to 1000 psi and 0.001 lb/sec
– Instrumented for temperature, pressure, flow rates and mass spec. analysis of exhaust