NSTX XP802 results - S.A. Sabbagh XP802: Active RWM stabilization system optimization and ITER...
-
Upload
agatha-joseph -
Category
Documents
-
view
216 -
download
0
Transcript of NSTX XP802 results - S.A. Sabbagh XP802: Active RWM stabilization system optimization and ITER...
![Page 1: NSTX XP802 results - S.A. Sabbagh XP802: Active RWM stabilization system optimization and ITER support Goals Alter active control configuration to achieve.](https://reader035.fdocuments.us/reader035/viewer/2022062409/5697bfa71a28abf838c9909a/html5/thumbnails/1.jpg)
NSTX XP802 results - S.A. Sabbagh
XP802: Active RWM stabilization system optimization and ITER support
• Goals Alter active control configuration to achieve highly reliable RWM
stabilization at various plasma rotation,
• Upper/lower RWM Br, Bp sensors, follow from best CY2007 feedback settings
• Br sensor feedback provides RFA correction, Bp provide RWM stabilization
• Determine if stable, low < i operation exists with feedback turned off
• If achieved, control system open as a tool for all NSTX XPs as desired
Specific ITER support requests
• Study effect of applied time delay on feedback (requires control system time delay capability)
• Determine impact of a large toroidal gap on active RWM stabilization to simulate ITER port plug coil geometry (take out one of six control coils)
• Addresses Joule milestone, ITER Organization (IO) request, NSTX PAC request ITPA experiment MDC-2
Pro
gre
ss 4
/11
/08
![Page 2: NSTX XP802 results - S.A. Sabbagh XP802: Active RWM stabilization system optimization and ITER support Goals Alter active control configuration to achieve.](https://reader035.fdocuments.us/reader035/viewer/2022062409/5697bfa71a28abf838c9909a/html5/thumbnails/2.jpg)
NSTX XP802 results - S.A. Sabbagh
Initial RWM signature leads to rotating global kink
• Transition to global kink indicates that mode is an RWM
off 1
2
zoomed view
1
1
Bpn=
1 N
Bn=
odd
Brm
idn=
1
Bpn=
1 N
Bn=
odd
Bpn=
1
RFA RFA reduced
n = 1 feedback on
![Page 3: NSTX XP802 results - S.A. Sabbagh XP802: Active RWM stabilization system optimization and ITER support Goals Alter active control configuration to achieve.](https://reader035.fdocuments.us/reader035/viewer/2022062409/5697bfa71a28abf838c9909a/html5/thumbnails/3.jpg)
NSTX XP802 results - S.A. Sabbagh
USXR shows transition from RWM to global kink
• Initial RWM locked signature spins up, amplitude dies away
K. Tritz
edge
edge
core
1
![Page 4: NSTX XP802 results - S.A. Sabbagh XP802: Active RWM stabilization system optimization and ITER support Goals Alter active control configuration to achieve.](https://reader035.fdocuments.us/reader035/viewer/2022062409/5697bfa71a28abf838c9909a/html5/thumbnails/4.jpg)
NSTX XP802 results - S.A. Sabbagh
Tearing mode appears significantly after global kink
• Significantly different than DIII-D results (H. Reimerdes)
K. Tritz
edge
core
edge
core
RWM + 20 ms + 30 ms
+ 40 ms + 50 ms
![Page 5: NSTX XP802 results - S.A. Sabbagh XP802: Active RWM stabilization system optimization and ITER support Goals Alter active control configuration to achieve.](https://reader035.fdocuments.us/reader035/viewer/2022062409/5697bfa71a28abf838c9909a/html5/thumbnails/5.jpg)
NSTX XP802 results - S.A. Sabbagh
Terminating event appears to be an internal kink
• n = 1 LMD shows mode lock (RWM?) preceding/concurrent w/kink
• Internal kink precedes H-L back-transition
2
K. Tritz
edge
edge
core Zoomed in view
![Page 6: NSTX XP802 results - S.A. Sabbagh XP802: Active RWM stabilization system optimization and ITER support Goals Alter active control configuration to achieve.](https://reader035.fdocuments.us/reader035/viewer/2022062409/5697bfa71a28abf838c9909a/html5/thumbnails/6.jpg)
NSTX XP802 results - S.A. Sabbagh
n = 1 feedback / RWM results show stabilization detail
• General conclusions (so far) n = 1 feedback system has produced far greater reliability of
discharge avoiding RWM
• Statistics being compiled n = 1 feedback system does not insure stability against RWM
• Reasons for failure being analyzed (e.g. fast mode growth) Mode characteristics appear to be RWM, not tearing
• Unlike present observation/conclusion by DIII-D
• Mode spin up, converts to global kink mode initially, tearing appears later
• Feedback system might be easing transition to rotating kink by altering boundary condition
Results to date question the validity of a “critical rotation” for RWM
• Next Steps Analysis of XP830 RWM Stabilization Physics (Berkery), and related
analysis to test kinetic stabilization model producing “bands” of stability/instability in rotation, beta