NPL REPORT MAT 8 Evaluation of the thermal performance of insulation systems used in roof structures Ray Williams Graham Ballard NOT RESTRICTED
December 2007
![Page 2: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/2.jpg)
![Page 3: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/3.jpg)
NPL Report MAT 8
Evaluation of the thermal performance of insulation systems used in roof structures
Ray Williams
Graham Ballard
Industry and Innovation Division ABSTRACT This report contains the results of a series of U-value measurements on a roof structure insulated with a variety of insulation systems; results of thermal performance measurements carried out using non-steady state temperature conditions and a brief review of the possible methods for determining the thermal performance of insulation systems based on reflective multifoil products. The thermal transmittance measurements were carried out using the NPL rotatable hot-box facility of a section of roof, insulated with four different insulation systems i) Actis Triso-Super 10 reflective multifoil, ii) Celotex TUFF-RTM rigid polyisocyanurate foam iii) Knauf Rafter Roll 32 glass fibre, iv) and four off, 25 mm deep air cavities with low emittance surfaces. The U-values of the four insulated roof systems were measured at four orientations which were i) the test element mounted vertically with horizontal heat flow, ii) at forty five degrees and iii) horizontally with upward heat flow and iv) mounted horizontally with downward heat flow. The measurement at forty-five degrees was repeated with a small airflow allowed into the air cavity between the tile membrane and the insulation. The U-values measured for these insulated roof structures are in agreement with values that were predicted from classic steady state heat transfer theory, which was demonstrated by calculating the U-value for each roof type using 2D finite element analysis, and air cavity thermal resistance values calculated using the procedures specified in BS ISO 15099. Temperature cycling measurements were carried out on a low-density glass fibre specimen and an air cavity insulated with Actis Triso-Super 10 reflective multifoil insulation. The energy used per 24 hours (in Watt-hours) obtained from the temperature cycling measurements show the energy required to cycle the low density glass fibre and the air cavity insulated with Actis Triso-Super 10 were within approximately 17% of each other with much of the difference resulting from differences in thermal resistance and the effect of temperature difference on the thermal resistance of air cavities. A brief review of the various methods of evaluating the thermal performance of reflective multifoil insulation products has also been carried out.
![Page 4: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/4.jpg)
NPL Report MAT 8
© Crown copyright 2007 Reproduced with the permission of the Controller of HMSO
and Queen's Printer for Scotland
ISSN 1754-2979
National Physical Laboratory Hampton Road, Teddington, Middlesex, TW11 0LW
The authors gratefully acknowledge the financial support of the National Measurement System Programmes Unit of the UK Department for Innovation, Universities and Skills.
No extracts from this report may be reproduced without the prior written consent of the Managing Director, National Physical Laboratory; if consent is given the source must be
acknowledged and the extracts may not be used out of context.
Approved on behalf of the Managing Director, NPL
by Susan Evans, Director, Industry and Innovation Division
![Page 5: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/5.jpg)
NPL Report MAT 8
CONTENTS
1 Background ..................................................................................................................... 1 2 Summary of the heat transfer processes through insulated air cavities.................... 2
2.1 Steady State heat transfer through an insulated air cavity ........................................... 2 2.1.1 The three modes of heat transfer ........................................................................ 2 2.1.2 Definition of steady state.................................................................................... 2 2.1.3 Overview of heat transfer processes in different types of insulation ................. 2
2.1.3.1 Insulation materials based on trapped air ................................................... 2 2.1.3.2 Insulation materials based on trapped high density gases.......................... 2 2.1.3.3 Insulation utilising low emittance surfaces ................................................ 2 2.1.3.4 Insulation utilising air at reduced pressure................................................. 3 2.1.3.5 Insulation only using particle size and radiation blocking......................... 3
2.1.4 Heat transfer through air cavities ....................................................................... 3 2.1.5 Heat transfer processes across an insulated cavity having cold bridges ............ 5
2.2 Non steady state thermal properties ............................................................................. 6 3 Review of methods of evaluating the thermal performance of multifoil insulation systems....................................................................................................................................... 7
3.1 Measure thermal resistance and emittance and calculate air cavity resistance............ 7 3.2 Measure thermal resistance of air cavity in hot box apparatus .................................... 7 3.3 Measure the thermal transmittance of a representative structure in a hot box............. 8 3.4 Measurement apparatus utilising the real outdoor environment. ................................. 9 3.5 Compare products installed in identical “simple buildings” exposed to real environment. ........................................................................................................................ 10 3.6 Insulate a “real building” and monitor energy use..................................................... 10
4 CEN activities related to thermal performance of reflective insulation .................. 11 5 Hot box measurements carried out at NPL................................................................ 11
5.1 Description of the NPL hot box and measurement procedures ................................. 11 5.2 Results of previous hot box measurements of reflective insulation products............ 14
5.2.1 Measurements of simple air cavity resistance.................................................. 14 5.2.2 Representative roof structures.......................................................................... 15
5.3 Hot box measurements of insulated roofs carried out for this project ....................... 15 5.3.1 Description of insulated roof structures that were tested ................................. 15 5.3.2 Results of the thermal transmittance measurements ........................................ 16
5.4 U-values modelled using 2D Finite Element Analysis (FEA)................................... 23 6 Temperature cycling measurements carried out in a heat flow apparatus............. 23
6.1 Description of apparatus and control system ............................................................. 23 6.2 Overview of specimens and measurements ............................................................... 24 6.3 Heat flow meter steady state results........................................................................... 24 6.4 Heat flow meter temperature cycling measurements ................................................. 24
7 Discussion of results...................................................................................................... 29 7.1 Hot Box results........................................................................................................... 29
7.1.1 The measured U-values.................................................................................... 29 7.1.2 The effect of direction of heat flow.................................................................. 29 7.1.3 Effect of allowing air flow into the external air cavity .................................... 29
7.2 Heat Flow Meter measurements and the non-steady state results.............................. 30 8 Summary of project and conclusions .......................................................................... 33
8.1 Summary of project.................................................................................................... 33 8.2 Conclusions................................................................................................................ 34
![Page 6: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/6.jpg)
NPL Report MAT 8
FIGURES Figure 1 Heat transfer processes through insulated air cavity showing the important
parameters. ......................................................................................................................... 6 Figure 2 Test element used to measure the thermal resistance of an air cavity in a hot box .... 8 Figure 3 Typical representative roof structure test element ..................................................... 9 Figure 4 Schematic diagram of Rotatable Hot Box ................................................................ 13 Figure 5 Historic values:- Thermal resistances of air cavity vs orientation............................ 14 Figure 6 Historic air cavity values:- Thermal resistance vs air cavity depth. ......................... 14 Figure 7 Position of perforated metal strip.............................................................................. 16 Figure 8 Cross section sketch of test element insulated with Triso-Super 10......................... 17 Figure 9 Cross section sketch of test element insulated with Celotex TUFF-RTM GA 3050
rigid polyisocyanurate foam............................................................................................. 18 Figure 10 Cross section sketch of test element insulated with Knauf Rafter Roll 32 glass fibre
.......................................................................................................................................... 19 Figure 11 Cross section sketch of test element insulated with reflective air cavities only ...... 20 Figure 12 THERM Model of Roof section insulated with Triso-Super 10............................. 23 Figure 13 Sketch of the LaserComp FOX 600 heat flow meter hot plate apparatus ............. 24 Figure 14 Test 5 Cycling glass fibre – Mean temperature 10 °C ± 10 °C ............................... 26 Figure 15 Test 6 Cycling glass fibre -Mean temperature 25 °C ± 10 °C ............................... 26 Figure 16 Test 7 Cycling glass fibre - Mean temperature 40 °C ± 10 °C ............................. 27 Figure 17 Test 12 Cycling Actis Triso-Super 10 - Mean temperature 10 °C ± 10 °C ........... 27 Figure 18 Test 13 Cycling Actis Triso-Super 10 Mean temperature 25 °C ± 10 °C ............ 28 Figure 19 Test 14 - Cycling Actis Triso-Super 10 Mean temperature 40 °C ± 10 °C .......... 28
TABLES Table 1 Effect of temperature difference and emittance on cavity thermal resistance ............ 4 Table 2 Effect of cavity depth on air cavity thermal resistance ............................................... 5 Table 3 Effect of orientation on air cavity thermal resistance .................................................. 5 Table 4 A typical set of experimental measured values........................................................... 21 Table 5 Measured and calculated U-values of the four insulated roof systems. ...................... 22 Table 6 Results of the heat flow meter apparatus measurements ............................................ 25 Table 7 Effect on measured U-value of orientation; air infiltration; direction of heat flow .... 30 Table 8 Analysis of the heat flow meter apparatus measurements .......................................... 32 Table 9 Comparison between measured and calculated U-values ........................................... 35
![Page 7: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/7.jpg)
Page 1 of 36 NPL Report MAT 8
1 Background In recent years, controversial claims have been made for the thermal performance of some insulation systems based on the use of low emittance surfaces. The controversy centres around the claims that some of these insulation systems, having an average thickness of 50 mm or less, when fixed in the centre of an air cavity produce an air cavity thermal resistance equivalent to that produced by 200 mm of glass fibre having a thermal conductivity of 0.04 W/m.K; that is equivalent to a thermal resistance of 5 (m2.K)/W. Simple calculations indicate that the best thermal resistance that can be achieved with a 50 mm thick insulation material (based on air) and two air cavities is about 3.3 m2.K/W and in practice it is likely to be lower than that. Some of those who have made the measurements on which such claims are based believe that the standard measurement methods such as those carried out using a hot box apparatus, do not measure the heat transfer processes that are occurring in their products. There have also been suggestions that the thermal performance of these products will be enhanced when subjected to non-steady state environmental conditions. There are a number of factors contributing to the problems associated with the thermal performance of these products. They are: • The thermal performance of these products is application specific. They rely on increasing
the thermal resistance of an air cavity and are not therefore fully characterised by considering simply their own intrinsic properties.
• There are no CEN product standards for these insulation systems. • Consumers and specifiers often have a poor understanding of the heat transfer principles
involved, leaving them unable to make their own judgement. • Most of the thermal performance values obtained to date are “commercially in
confidence”. • Some organisations have developed “in-house”, comparative measurement procedures
using outdoor environments. These methods are not publicly documented, may not be rigorously validated and could be subject to large measurement uncertainties.
This report: • Summarises the heat transfer processes involved when a structure is insulated with these
types of product. • Gives a brief review of the measurement and calculation standards associated with
traditional insulation materials and structures. • Reviews the various measurement methods available to evaluate these types of products. • Lists other activities taking place to resolve these issues. • Describes thermal transmittance measurements made by NPL on representative roof
structures insulated with different insulation systems, in a hot-box apparatus. • Describes power consumption measurements made of low-density glass fibre and an air
cavity insulated with Actis Triso-Super 10, in the non-steady state, in a specially adapted guarded heat-flow-meter apparatus.
![Page 8: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/8.jpg)
NPL Report MAT 8 Page 2 of 36
2 Summary of the heat transfer processes through insulated air cavities
2.1 Steady State heat transfer through an insulated air cavity
2.1.1 The three modes of heat transfer • Conduction – the heat transfer process through solids • Convection – heat transfer through fluids (in building situations this is usually air). • Radiation –heat transfer by electromagnetic radiation emitted from the surface of an
object, which is due to the object's temperature. This mode of heat transfer does not require a medium to pass through i.e it can pass through a vacuum.
2.1.2 Definition of steady state • The external temperatures of the cavity are constant with time. • The heat energy supplied is used solely to produce the temperature difference across it. • No heat energy is heating up the materials used to make the structure neither is any being
lost in cooling the structure. • Neither the mass nor specific heat of the insulation and structure are important.
2.1.3 Overview of heat transfer processes in different types of insulation
2.1.3.1 Insulation materials based on trapped air Materials such as glass fibre or expanded polystyrene (which have thermal conductivity values of around 0.038 W/m.K are considered to be homogenous and work by using a minimum of material to inhibit both heat transfer by convection and by thermal radiation. The material used (e.g. the glass fibres) also creates an additional heat transfer path by allowing thermal conduction through the material itself. In the case of glass fibre, there is an optimum density where the effect on minimising convection and radiation is greater than the increase in heat transfer by thermal conduction though the glass fibres themselves. Reduce the density below that optimum value and the thermal conductivity starts to rise (quite sharply) due to the increased thermal radiation passing through the material. But when the density is increased from this optimum value, however, the thermal conductivity also starts to rise (this time more gradually) due to the increased thermal conduction through the glass fibres.
2.1.3.2 Insulation materials based on trapped high density gases Although the principle is the same i.e. to reduce convection and radiation by using as little material as possible (for the same reasons as above) – these materials have the advantage of having the expanded polymer foam filled not with air but with blowing gases such as hydrofluorocarbons (HFCs) or hydrochlorofluorocarbons (HCFCs) which have a lower thermal conductivity than air. This means that some of these materials can have a lower thermal conductivity than air, values of 0.018 W/m.K are possible - but have to be clad in some way to stop those gases diffusing out of the polymer matrix. The producer must quote a 25 year design value based on accelerated aging measurements.
2.1.3.3 Insulation utilising low emittance surfaces Using low emittance surfaces to reduce radiant heat exchange is a well-established technique (Sir James Dewar famously used silver to enhance the performance of his famous vacuum
![Page 9: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/9.jpg)
Page 3 of 36 NPL Report MAT 8
flask in 1882). Some manufacturers of materials such as polyurethane and glass fibre supply products with a low emittance outer layer. The product that is of special interest for this report, however, is the one that comprises a number of layers of low density wadding between thin membranes with low emittance surfaces. The outer membranes of such products are usually of rather more robust materials but again with low emittance surfaces. The low density wadding is there to inhibit convection of the air between the membranes, again using the minimum of material which again provides an additional heat transfer path by thermal conduction. The density can be lower than for uncovered material because the low emittance membranes serve to reduce the thermal radiation through the wadding. With conventional wadding material, the thermal resistance between each layer cannot be less than for still air. The outer, low emittance surfaces have to be taken advantage of by ensuring the product is installed in such a way as to create an air cavity in front of each outer surface. The low emittance surface acts to increase the thermal resistance of those unventilated air cavities exactly as low emittance coating such as Pilkington K, does in a double glazed window unit. The use of low emittance surfaces to improve thermal insulation is a well-established technique and has been used for decades in many different applications. The vacuum flask has already been mentioned but other examples are for cryogenic insulation where the gaps between the reflective layers are usually evacuated and at high temperatures where the Stefan's Law relationship between radiant energy and the forth power of the absolute temperature makes concentric “reflective radiation shields” common practice.
2.1.3.4 Insulation utilising air at reduced pressure A vacuum is an extremely efficient insulator because it totally excludes conduction and / or convection through the gas (steps have to be taken to reduce radiant exchange of course).. The relationship between gas pressure and thermal conductivity is, however, such that to achieve thermal conductivity values about 0.001 W/m.K (compare with 0.025 W/m.K for air at atmospheric pressure) the gas pressure must be below about 0.001 mbar, very difficult to achieve and sustain over long periods of time. If, however, the gas space is filled with particles whose diameter is similar to the means free path of the gas molecules then thermal conductivity values of around 0.005 W/m.K can be achieved with gas pressures of about 1 mbar to 10 mbar.
2.1.3.5 Insulation only using particle size and radiation blocking Some materials utilise the above effect without any reduction in gas pressure at all. These are often some type of Aerogel material whose pore diameters are closely matched to the mean free path of the air. These can achieve thermal conductivity values of around 0.014 W/m.K
2.1.4 Heat transfer through air cavities The thermal performance of an unventilated air cavity is well understood – it depends on:-
• Cavity depth • Cavity aspect ratio (height to depth) • Total hemispherical emissivity of the bounding surfaces • Temperature difference across the cavity • Orientation with respect to gravity. • Gas type (but for most building applications it is air).
![Page 10: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/10.jpg)
NPL Report MAT 8 Page 4 of 36
The glazing industry routinely calculates the thermal resistance of air (or even gas filled) cavities using the procedures in BS EN 673 or BS ISO 15099. A simple procedure for calculating the thermal resistance of an air cavity bounded by one low emittance surface and one high emmittance surface is given in BS EN ISO 6946 and tables of air cavity thermal values for different temperature differences and different emittance are given in the ASHRAE Book of Fundamentals. The effects of orientation, temperature difference, emittance and cavity depth can be seen by looking at the air cavity thermal resistance values given in Table 1 (effect of temperature difference and emittance), Table 2 (effect of cavity depth) and Table 3 (effect of orientation). All these values were calculated using the procedures specified in BS ISO 15099. It can be seen from the values in those tables that the thermal performance of any structure insulated with one or more air cavities will depend on all these parameters. Table 1 Effect of temperature difference and emittance on cavity thermal resistance
The other surface
ε = 0.05
The other surface
ε =0.1
The other surface
ε = 0.2
The other surface
ε = 0.4
Temperature difference
(°C)
Gas space thermal
resistance (m2.K/W)
Gas space thermal
resistance (m2.K/W)
Gas space thermal
resistance (m2.K/W)
Gas space thermal
resistance (m2.K/W)
30 0.28420 0.31116 0.32714 0.33812 0.35110 0.3699 0.3808 0.3947 0.4116 0.4345 0.466 0.414 0.341 0.2624 0.5083 0.5632 0.671
* Cavity mean temperature = 10 °C
Cavity thermal resistances calculated using procedures given in BS ISO 15099
* Cavity at 45 degrees - heat flow up.* Cavity depth is 25 mm
* One side of the cavity has an emmittance of 0.9
![Page 11: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/11.jpg)
Page 5 of 36 NPL Report MAT 8
Table 2 Effect of cavity depth on air cavity thermal resistance
Table 3 Effect of orientation on air cavity thermal resistance
2.1.5 Heat transfer processes across an insulated cavity having cold bridges
The various heat transfer processes that take place across an insulated air cavity, with cold bridges, are listed below and shown in Figure 1 – which also shows the important parameters for each of the modes of heat transfer. • From the warm environment into the structure. • Through the walls of the cavity by conduction – (Note: When the air cavity thermal
resistance has been measured at NPL, the surface temperature of the inside face of the air cavity has been used and so the thermal resistance of the cavity walls are excluded).
• Across the warm side air cavity (see details below) • Through any bridging structure (eg rafters) • Though the insulation material (see description above) • Across the cold side air cavity (see details below) • Through any bridging structure (eg rafters) • Through the walls of the cavity by conduction • From the cavity wall to cold environment
100
Gas space thermal
resistance (m2.K/W)
ISO 15099 45 degree cavity - heat up - ε1 = 0.9 & ε2 = 0.1 @ Mean temp = 10 °C & Temperature difference = 5 °C
0.377 0.414 0.436 0.479 0.506
50 75Cavity depth (mms) 12 25
ISO 15099 - ε1 = 0.9 & ε2 = 0.1 @ Mean temp = 10 °C & Temperature difference = 5 °C & Cavity depth 50 mms
Heat flow direction
0.932
Gas space thermal
resistance (m2.K/W)
0.505 0.436 0.408
![Page 12: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/12.jpg)
NPL Report MAT 8 Page 6 of 36
Figure 1 Heat transfer processes through insulated air cavity showing the important parameters.
2.2 Non steady state thermal properties The thermal performance of insulation systems in non-steady state conditions (where one or more of the boundary temperatures change with time) is specific to the application and the nature of the non-steady state conditions to which the application is subjected. Under these conditions, the simple equations used to calculate steady state heat transfer no longer apply. The usual procedure for components used in buildings is to measure the steady state properties of the materials (in a hot plate apparatus) or of complete sub-sections (in a hot box apparatus) using standard apparatus and procedures and then use that data to calculate the non-steady state performance of the whole building over a defined period of time (day, week, month or year) when it is subjected to a particular set of weather conditions. The direct measurement of overall thermal performance of building components in a real, non-steady state environment is difficult and up to now has rarely been attempted. Facilities have been built to measure the thermal performance of glazed products by measuring the net heat flow through them, when exposed to the real environment, so enabling the complex effects of the solar gain at different angles throughout a day and over many months to be determined. The best example of such a facility is at EMPA in Switzerland. It is a complex and very expensive facility that is mainly used for research.
Key
Warm side
Cold side
Thermal conduction
Thermal radiation
Thermal convection
Wood rafterThermal conductivity = λ5
Thickness = w5
Cross section area = A5
InsulationThermal conductivity = λ4
Thickness = w4
Cold surrounding surfaceTemperature = T9
Emmittance = ε9
Warm surrounding surface:Temperature = T1
Emittance = ε1
Warm Air Temperature = T2
Velocity = V2
Warm cavity surface Temperature = T3
Emittance = ε3
Reflective surface Temperature = T6
Emittance = ε6
Internal cavity - cold surfaceTemperature = T7
Emittance = ε7
Cold Air Temperature = T8
Velocity = V8
Cavity wallsThermal conductivity = λ10
Thickness = w10
Cross section area = A10
![Page 13: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/13.jpg)
Page 7 of 36 NPL Report MAT 8
3 Review of methods of evaluating the thermal performance of multifoil insulation systems.
3.1 Measure thermal resistance and emittance and calculate air cavity resistance Currently a European Technical Approval (ETA) is being produced for these products. An ETS is produced when no harmonized European specification for the product exists. In that case the European Organisation for Technical Approvals (EOTA) and it’s approval bodies can issue a ETA, which will allow the product to be sold with the CE marking in the European Economic Area. ETAs are based on a Common Understanding of Assessment Procedures (CUAP) for specific products. The CUAP being produced utilises the following method of determining the thermal performance of these products:
i) Measure the thermal resistance of the product in a hot-plate apparatus ii) Measure the total emittance of the external surfaces.
iii) Calculate the thermal performance of any structure it was used to insulate. This method suffers from two problems.
1) Many of the reflective multifoil products do not have a uniform shape, some are in fact “quilted” and so measuring their thermal resistance accurately in a hot plate apparatus is difficult. This difficulty is increased by the low emittance external surfaces that will have an effect on the small air cavities that are created between the external surfaces of the product and the hot and cold plates of the apparatus. In the CUAP method, an attempt is made to account for this additional thermal resistance by spraying the product matt black and re-measuring it. Then, assuming the air cavities created are the same for both measurements, the thermal resistance of the external air cavities is estimated and deducted from the overall thermal resistance value.
2) Measuring the emittance of the external surfaces is difficult. There are no standards for
making emittance measurements of these types of surface and very few institutes are involved in carrying them out. The rigorous method of making emittance measurements is expensive and requires a very flat surface. There is one very simple device for measuring emittance covered by ASTM C1371, but there is only one manufacturer of this device and it has never been independently validated. It is repeatable but the absolute measurement uncertainty of the technique is not known. It can only be used on material with high thermal conductivity, so it cannot be used on made-up insulation products. The emittance of many plastic coated, aluminium materials must be measured after fabrication because the heating involved in manufacture can alter the emittance of the surface because of the effect on the plastic coating.
3.2 Measure thermal resistance of air cavity in hot box apparatus The product under investigation is mounted in the centre of an unventilated air cavity, typically 2 m long by 1 m wide and is kept in position by a number of small, expanded polystyrene pillars (Figure 2). The temperature of the inside surfaces of the cavity are measured by nine thermocouples on each surface. The power through the system is measured and the thermal resistance of the insulated cavity measured. This has a number of advantages over the method described in section 3.1. These are:- • No need to measure emittance of the two external surfaces • No need to measure intrinsic thermal resistance
![Page 14: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/14.jpg)
NPL Report MAT 8 Page 8 of 36
• Irregular shaped products do not pose a problem • Thermal effects of overlaps used in practice can be accounted for. • Real convective effects are measured – ie not reliant on calculations using simplified
convection correlations. • It can be measured at whatever orientation is appropriate. The thermal resistance values produced can then be used in a variety of calculation procedures to determine the U-value of the actual application.
Figure 2 Test element used to measure the thermal resistance of an air cavity in a hot box
3.3 Measure the thermal transmittance of a representative structure in a hot box. In this method a representative section of actual roof (or wall or floor) structure is made insulated with the target product and its U-value measured in the appropriate orientation. Sections up to 2 m x 2 m can be measured in the NPL rotatable hot box, but usually specimens approximately 1.5 m x 1.25 m are used. This was the procedure adopted for the measurements made for this project. A typical insulated roof structure is shown in Figure 3. This value includes all the effects of the cold bridging due to the rafters. Advantages of this method;
i) Output directly gives U-value data for a specific structure – no calculations needed. ii) It will give a value very near the actual U-value of the actual roof.
Disadvantage of the method:
i) A separate test is needed for each structure
Hot Box test element to measure the thermal resistance of an air cavity insulated with insulation using reflective surfaces
Cavity walls can be made from any material - eg plywood or MDF. Their thermal resistance is NOT included in the measured value.
Thermocouples measure the INSIDE surface temperature of the cavity walls.
Small expanded polystyrene pillars insure minimum air cavity depth is maintained.
Expanded polystyrene surround panel. - This could be either 150 mm or 300 mm thick.
Greater than 25 mm - According to EN ISO 6946 - this will then be representative of any air gap from 25 mm to ~ 300 mm. - A wide range of air gaps could be produced.
Insulation - could be of any type. This arrangement measures the thermal resistance of the insulated air cavity without the need to measure i) intrinsic thermal resistance ii) emissivity iii) cavity geometries
![Page 15: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/15.jpg)
Page 9 of 36 NPL Report MAT 8
Figure 3 Typical representative roof structure test element
3.4 Measurement apparatus utilising the real outdoor environment. This is a test cell with the specimen exposed to the real climate. The difficulties in carrying out accurate measurements and extracting the thermal performance values for individual components of a structure increase dramatically when real climatic conditions are used. The varying effects of wind, rain, solar gain and fluctuating air temperature make interpreting the measured data very difficult. There have been a number of attempts to do this. The EU PASSYS Programme and the EMPA Solar Heat Gain facility are good examples. Advantages:
i. Controlled and monitored interior environment; monitored exterior environment. ii. Performance measured will include solar gain.
iii. Performance will include thermal inertia effects. iv. It is an absolute method
Disadvantages
i. Very difficult to extract “standard” thermal performance data from the results as it requires complex mathematics [1].
All dimensions in mmsNOT TO SCALE
NOTE: The sample should be 1478 ± 2 mm long
Tile felt - tiles could also be fixed if required - but we do not usually.
Rafter - dimensions as required
"Half" thickness rafter at each side - Used to ensure that a representative area of wood is used.
Counter battens (suggest 3 off - one at each end and one in the middle). Need to be deep enough to ensure a 25 mm gap between reflective insulation and plasterboard is created - even allowing for the bulging of the insulation
Plasterboard ~12 mm (Could be Aluminium foil backed)
Multifoil reflective insulation -
Expanded polystyrene surround panel - part of Hot Box Apparatus
Normally 1228 ± 2 wide
~ 408 ~ 408 ~ 408
Overall cavity depth could be up to ~ 280
Usually > 50
> 25
![Page 16: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/16.jpg)
NPL Report MAT 8 Page 10 of 36
3.5 Compare products installed in identical “simple buildings” exposed to real environment. This is the method used by most institutes that have produced the controversial thermal performance values for reflective insulation products. The important issues when carrying out these types of measurement are:-
i. Carry out a sensitivity analysis of the system. For example what percentage of the total energy used goes through the floor and the cold bridging rafters. What percentage of the measured energy goes into heating up the structure? Is the measurement method sensitive enough to detect differences between the two samples being compared?
ii. Ensure both simple building are the same thermally (carry out measurements of the
buildings in a non-insulated state in the same types of weather conditions that will be used to compare the products.
iii. Ensure the reference material is well characterised and installed as perfectly as possible
and in a manner required by the manufacturer of that product.
iv. Validate the whole system by measuring another reference material in the “other” building. For example if 100 mm thick expanded polystyrene was used as the reference material in building 1 use 50 mm of the same expanded polystyrene in building 2.
v. Measure the air infiltration rates for the buildings with both the reference material and the
target material. Then calculate what effect air infiltration that is having on the measured energy used. It should be remembered that the energy used to keep these well insulated buildings (U-value of the whole building approximately 0.2 W/m2.K which is much lower than for a “normal” building) at a normal indoor temperature of say 25 °C, will be quite low and therefore the energy used to warm the infiltrating cold air will be a significant percentage of the total.
Advantages
i. Will take into account the effects of installing materials in an almost real situation e.g. how such features as joins and overlaps are dealt with.
Disadvantages
i. Very difficult to extract steady state thermal performance data for the insulation from the measured data.
ii. Results specific to that structure and cannot be extrapolated to other structures. iii. Results specific to the weather conditions present during that test. iv. Low measurement sensitivity due to large and un-quantified heat transfer associated with
changing the temperature of the “building” structure, heat transfer through the “cold bridging” of the rafters and through the large area of floor.
3.6 Insulate a “real building” and monitor energy use This would mainly be used to check the whole building energy calculation not the performance of one part of the structure. It would be very difficult to determine the thermal performance of one component of the building from such measurements.
![Page 17: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/17.jpg)
Page 11 of 36 NPL Report MAT 8
4 CEN activities related to thermal performance of reflective insulation Below is a list of current CEN activities related to resolving these measurement problems.
i. Common Understanding of Assessment Procedure (CUAP) Contact: CSTB, 84, avenue Jean Jaurès, Champs-sur-Marne,
77447 Marne-la-Vallée cedex 2, France
ii. CEN TC89 WG12 – Standardisation of the assessment of the thermal performance of products based upon or utilising reflective or low emittance layers. Contact: Carol Houghton, CJHconsult Associates [carol@cjhconsult-
associates.co.uk]
iii. CEN Workshop - Evaluation of Thin Multilayer Reflective Insulation Products by in situ Testing. Contact: CEN Management Centre, Ms Gaïd Le Gall, Programme manager,
Workshops, CEN European Committee for Standardization. [[email protected]]
5 Hot box measurements carried out at NPL
5.1 Description of the NPL hot box and measurement procedures The NPL thermal transmittance facility comprises two hot-box apparatus accredited to by UKAS to carry out measurements to EN ISO 8990, EN ISO 12567-1 and EN ISO 12567-2. The UKAS accreditation is to the EN ISO 17025 accreditation standard. The rotatable hot-box used to carry out the measurements reported in Section 5.3 is capable of carrying out measurements with the test element positioned in any position from horizontal with vertically up heat flow through to horizontal with vertically down heat flow (important when the sample includes air cavities). A side elevation, cross sectional sketch of the two chambers comprising the hot-box apparatus is shown in Figure 4. The hot-box apparatus is designed to measure the total heat transfer through large, non-homogeneous structures, where the heat transfer into and out of the specimen involves both convective and radiant heat transfer and the heat transfer through the specimen can involve any combination of conduction, convection and radiation. The design and operation of the hot-box apparatus are specified in EN ISO 8990 and EN 1946 Part 4 and the details of the validation measurements are given in NPL Report CBTLM 25 “Validation of the NPL rotatable wall guarded hot box with horizontal heat flow” and NPL Report DEPC-TH-002 “An investigation of measurement procedures needed to determine thermal transmittance of deep structures using both horizontal and vertical heat flow”. The apparatus comprises a hot chamber and a cold chamber. The specimen is fixed between the two chambers, mounted in a surround panel made from insulation material of known thermal properties. Both chambers are designed to enable the following:- Air movement:
• Produced • Controlled • Measured
![Page 18: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/18.jpg)
NPL Report MAT 8 Page 12 of 36
These temperatures to be measured:
• Air • Surface of the surround panel • Specimen surface • Surfaces radiating to the specimen Most importantly and the most difficult to achieve - the hot chamber of the apparatus is
designed and built to ensure that ALL the measured power produced in the hot chamber, to maintain a temperature difference across the specimen, actually goes through the specimen and surround panel. It is important that there is no significant heat flow out of or into the hot chamber, other than through the specimen and surround panel.
The total power used in the hot chamber is accurately measured.
The air temperature in the cold chamber is kept at a constant low temperature throughout
(often about 2 °C ) the measurement, by a suitable chiller system The NPL rotatable hot-box can carry out U-value measurements with the test specimen in any orientation; from vertical through to horizontal with the cold box above the hot- box or horizontal with the hot-chamber above the cold chamber. The overall measurement uncertainty of the U-value measurements made of these types of structures, with this apparatus, is estimated to be within ± 7.2% based on a standard uncertainty multiplied by a coverage factor k = 2, providing a level of confidence of approximately 95 %. The repeatability of the apparatus when measuring these types of structures has been determined to be within ± 2 %
![Page 19: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/19.jpg)
Page
13
of 3
6
NPL
Rep
ort M
AT
8
Figu
re 4
Sch
emat
ic d
iagr
am o
f Rot
atab
le H
ot B
ox
N
PL R
otat
able
Wal
l Gua
rded
Hot
Box
HO
T B
OX
CO
LD B
OX
X X
Hea
ter (
dc)
Fan
3Pha
se (P
rodu
ces
up to
6 m
/s a
ir flo
w
Hea
t ex
chan
ger
Baf
fle -
can
be m
oved
bac
k
Line
ar g
radi
ent C
olla
r G
uard
Sys
tem
Tem
pera
ture
gra
dien
t in
stee
l she
et
kept
the
sam
e as
in e
xpan
ded
poly
styr
ene
hold
er p
anel
Exp
ande
d po
lyst
yren
e ho
lder
pan
el
Spe
cim
en
Air
ther
moc
oupl
es
Hea
t flo
w m
eter
sys
tem
;90
00 μ
V /
°C
Hea
t flo
w k
ept t
o ze
ro w
atts
Insu
latio
n
Insu
late
d w
alls
Baf
fle th
erm
ocou
ples
X
Hol
der p
anel
th
erm
ocou
ples
Bot
tom
zon
e ex
tern
al w
all
guar
d he
ater
sys
tem
m
ount
ed o
n 6
mm
Al
shee
ts. T
emp
cont
rolle
d by
di
ff t/c
to to
p zo
ne
Rev
eal t
herm
ocou
ples
Top
zone
ext
erna
l wal
l gua
rd
heat
er s
yste
m m
ount
ed o
n
6 m
m A
l she
ets.
Tem
pera
ture
co
ntro
lled
with
ther
mis
or in
a
brid
ge c
ircui
t ~ 6
000
μV/°
C
Fan
(dc)
pro
duce
s ~
0.2
to 0
.5 m
/s a
ir flo
w
X X X
Spe
cim
en s
urfa
ce
ther
moc
oupl
esC
oppe
r fin
Diff
eren
tial
t/c s
yste
m
Baf
fle -
can
be m
oved
![Page 20: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/20.jpg)
NPL Report MAT 8 Page 14 of 36
5.2 Results of previous hot box measurements of reflective insulation products.
5.2.1 Measurements of simple air cavity resistance NPL has carried out twenty thermal resistance measurements of air cavities insulated with reflective insulation. These have included test elements comprising one and two air cavities; different cavity depths and measurements at different orientations. The range of total thermal resistance values measured is from 0.55 m2.K/W to 2 m2.K/W. The relationship between air cavity thermal resistance and it’s orientation for one and two cavities specimens (for one material) can be seen in Figure 5 and the variation of thermal resistance with cavity depth can be seen in Figure 6.
Figure 5 Historic values:- Thermal resistances of air cavity vs orientation.
Figure 6 Historic air cavity values:- Thermal resistance vs air cavity depth.
Thermal resistance of air cavity vstotal cavity depth of system (2 air cavity systems)
0.5
0.7
0.9
1.1
1.3
1.5
1.7
1.9
2.1
50 60 70 80 90 100 110 120 130 140
Total air cavity depth (mm)
The
rmal
res
ista
nce
(m2 .K
/W)
90 degrees 45 degrees 0 degrees
Thermal resistance of air cavity vs specimen orientationfor specimens comprising one and two cavities
(0 degrees = specimen vertical with horizontal heat flow)
1.25
1.50
1.75
2.00
0 15 30 45 60 75 90 105Orientation (degrees)
The
rmal
res
istan
ce
(m2 .K
/W)
1 cavity total 90 mm 2 cavities total 90 mm
![Page 21: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/21.jpg)
Page 15 of 36 NPL Report MAT 8
5.2.2 Representative roof structures A wide variety of roof structures have been measured at NPL and it is therefore difficult to draw simple conclusions from the results. They have all been of roofs with two full rafters and two half rafters (for explanation see section 5.3.1), insulation, plaster board and “tile felt”. Some have had more than one layer of reflective insulation. The measured U-values for those systems ranged from 0.3 W/(m2.K) to 0.86 W/(m2.K).
5.3 Hot box measurements of insulated roofs carried out for this project
5.3.1 Description of insulated roof structures that were tested The basic roof structure (see for example Figure 8 and Figure 9) comprised: Size 1.48m long x 1.23m wide Rafters 2 off 38mm wide wood rafters at 409mm centres and two off 19mm
wide “half” rafters down the sides of the structure. These half rafters ensured that the cross section area of rafters is representative of the whole structure. In essence the adiabatic cut lines you would use in a numerical model, bound the test element.
Insulation Fixed as appropriate (see individual sketches). Warm side A 12.5mm thick, aluminium foil-backed, plasterboard sheet was fixed
either to the to the counter-battens or the rafters as appropriate. Cold side A roofing membrane, Lafarge Veltitech 180 was fixed to the cold end
of the rafters creating a further air cavity between insulation and the membrane. This “cold side air cavity” was 50 mm deep for the traditional insulation and the special “layers of air cavities” insulation and approximately 100 mm deep with the Actis Triso-Super 10 insulation
External air vent To investigate effect of air movement in the “cold side air cavity”, a
perforated metal strip was fixed near the top and bottom of the membrane. The strip was taped over for the non-vented measurements and removed when air infiltration was required. The exposed, perforated metal strip was 25 mm wide with small (1.2 mm diameter) holes producing 42% of open area. The position of this strip is shown in Figure 7.
Overall thickness 162 mm of test element
![Page 22: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/22.jpg)
NPL Report MAT 8 Page 16 of 36
Four different insulation systems were measured. i. Actis Triso-Super 10 – see Figure 8
ii. Celotex TUFF-RTM GA 3050 – see Figure 9
rigid polyisocyanurate foam (λ = 0.023 W/m.K)
iii. Glass fibre Knauf Rafter Roll 32 – see Figure 10 (λ = 0.032 W/m.K)
iv. Reflective air cavities formed by 2 mm cardboard, – see Figure 11
covered on both sides with aluminium foil.
Figure 7 Position of perforated metal strip
5.3.2 Results of the thermal transmittance measurements A set of typical measured values used to derive the U-value from the measurements can be seen in Table 4. The measured U-values of all the test elements that are described in Section 5.3.1, in the different orientations, can be seen in Table 5.
50 mm25 mm
50 mm25 mm
Perforated metal strip (1.2 mm diameter holes - producing 42% open area)
![Page 23: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/23.jpg)
Page
17
of 3
6
NPL
Rep
ort M
AT
8
Figu
re 8
Cro
ss se
ctio
n sk
etch
of t
est e
lem
ent i
nsul
ated
with
Tri
so-S
uper
10
All d
imen
sion
s in
mm
sN
OT
TO S
CAL
E
Lafa
rge
Roo
fing
Velti
tech
Und
erla
yR
afte
r 100
mm
dee
p x
38 m
m th
ick
"Hal
f" ra
fter -
Use
d to
ens
ure
that
a
repr
esen
tativ
e ar
ea o
f woo
d is
use
d.
3 of
f cou
nter
bat
tens
- 50
mm
dee
p x
25 m
m w
ide
- to
ensu
re a
t a 2
5 m
m c
avity
form
ed b
etw
een
the
refle
ctiv
e in
sula
tion
and
plas
terb
oard
- ev
en a
llow
ing
for t
he
bulg
ing
of th
e in
sula
tion
Plas
terb
oard
~1
2 th
ick
(Alu
min
ium
foi
l ba
cked
)
Tris
o-Su
per 1
0 R
efle
ctiv
e in
sula
tion
-
Expa
nded
po
lyst
yren
e su
rrou
nd p
anel
- pa
rt o
f Hot
Box
Ap
para
tus
300
1228
± 2
~ 40
8 ~
408
~ 40
8
Ove
rall
cavi
ty
dept
h =
150
100
50
![Page 24: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/24.jpg)
NPL
Rep
ort M
AT
8 Pa
ge 1
8 of
36
Fig
ure
9 C
ross
sect
ion
sket
ch o
f tes
t ele
men
t ins
ulat
ed w
ith C
elot
ex T
UFF
-RTM
GA
305
0 ri
gid
poly
isoc
yanu
rate
foam
All
dim
ensi
ons
in m
ms
NO
T TO
SC
ALE
Lafa
rge
Roo
fing
Velti
tech
Und
erla
yR
afte
r 100
mm
de
ep x
38
mm
th
ick
"Hal
f" ra
fter -
Use
d to
ens
ure
that
a
repr
esen
tativ
e ar
ea o
f woo
d is
use
d.
Addi
tiona
l "ra
fter"
to m
ake
over
all d
epth
up
to 1
50 m
m (t
o m
ake
all r
oof c
aviti
es
test
ed th
e sa
me)
Plas
terb
oard
~12
mm
(Alu
min
ium
foil
back
ed)
Cel
otex
Tuf
f-RTM
GA3
050
insu
latio
nEx
pand
ed
poly
styr
ene
surr
ound
pan
el -
part
of H
ot B
ox
Appa
ratu
s
300
1228
± 2
~ 40
8 ~
408
~ 40
8
Ove
rall
cavi
ty
dept
h =
150
50
50
Alum
iniu
m
face
d
50
![Page 25: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/25.jpg)
Page
19
of 3
6
NPL
Rep
ort M
AT
8
Figu
re 1
0 C
ross
sect
ion
sket
ch o
f tes
t ele
men
t ins
ulat
ed w
ith K
nauf
Raf
ter
Rol
l 32
glas
s fib
re
All
dim
ensi
ons
in m
ms
NO
T TO
SC
ALE
Lafa
rge
Roo
fing
Velti
tech
Und
erla
yR
afte
r 100
mm
de
ep x
38
mm
th
ick
"Hal
f" ra
fter -
Use
d to
ens
ure
that
a
repr
esen
tativ
e ar
ea o
f woo
d is
use
d.
Add
ition
al "
rafte
r" to
mak
e ov
eral
l de
pth
up to
150
mm
(to
mak
e al
l roo
f ca
vitie
s te
sted
the
sam
e)Pl
aste
rboa
rd ~
12 m
m (A
lum
iniu
m fo
il ba
cked
)
Kna
uf R
afte
r Rol
l 32
Gla
ss fi
bre
insu
latio
nEx
pand
ed
poly
styr
ene
surr
ound
pan
el -
part
of H
ot B
ox
Appa
ratu
s
300
1228
± 2
~ 40
8 ~
408
~ 40
8
Ove
rall
cavi
ty
dept
h =
150
50
50 50
![Page 26: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/26.jpg)
NPL
Rep
ort M
AT
8 Pa
ge 2
0 of
36
Figu
re 1
1 C
ross
sect
ion
sket
ch o
f tes
t ele
men
t ins
ulat
ed w
ith r
efle
ctiv
e ai
r ca
vitie
s onl
y
All
dim
ensi
ons
in m
ms
NO
T TO
SC
ALE
Lafa
rge
Roo
fing
Velti
tech
Und
erla
yR
afte
r 100
mm
dee
p x
38
mm
thic
k
"Hal
f" ra
fter -
Use
d to
ens
ure
that
a
repr
esen
tativ
e ar
ea o
f woo
d is
use
d.
Addi
tiona
l "ra
fter"
to m
ake
over
all
dept
h up
to 1
50 m
m (t
o m
ake
all 3
ro
of c
aviti
es te
sted
the
sam
e)
Plas
terb
oard
~12
mm
(Alu
min
ium
foil
back
ed)
Div
ider
s m
ade
of B
risto
l bo
ard
with
alu
min
ium
foil
stuc
k to
bot
h si
des
(em
issi
vity
~ 0
.05)
300
mm
thic
k ex
pand
ed
poly
styr
ene
surr
ound
pan
el -
part
of t
he H
ot B
ox
Appa
ratu
s
300
1228
± 2
~ 40
8~
408
~ 40
8
Ove
rall
cavi
ty
dept
h =
150
mm
50
25
25
25
25
![Page 27: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/27.jpg)
Page
21
of 3
6
NPL
Rep
ort M
AT
8
Tab
le 4
A ty
pica
l set
of e
xper
imen
tal m
easu
red
valu
es
R05
8A4
Dat
a en
tere
d by
.....
GB
Serv
ice
num
ber..
.PP
31/D
TI P
roje
ct/1
Tris
o-Su
per 1
0 - V
ertic
al -
Clo
sed
Dat
a en
try
chec
ked
by...
..R
. Will
iam
s
Hol
der t
herm
al c
ondu
ctiv
ity d
ata
from
610
resu
lts
12
34
56
78
910
1112
1314
15D
ate
& T
ime
Spec
imen
Hol
der
Atm
.To
tal
Hol
der
Hol
der
Spec
imen
Spec
imen
Air
Air
Baffl
eBa
ffle
Div
iny
boun
dary
area
Th C
ond.
pres
sure
pow
erH
otC
old
Hot
Col
dte
mp
tem
pH
otC
old
Offs
etlo
sste
mp
tem
psu
rfac
esu
rfac
eH
otC
old
tem
pte
mp
(m²)
(W/m
.K)
(mb)
(W)
(°C
)(°
C)
(°C
)(°
C)
(°C
)(°
C)
(°C
)(°
C)
(uV
)(%
)
13/0
2/20
07 2
3:08
1.83
00.
0335
0.0
26.1
9321
.786
2.87
320
.581
3.09
122
.062
2.72
521
.704
2.80
55.
700.
5614
/02/
2007
01:
081.
830
0.03
350.
026
.133
21.7
792.
786
20.5
723.
007
22.0
572.
607
21.6
982.
711
-0.4
00.
5614
/02/
2007
03:
081.
830
0.03
350.
026
.141
21.7
722.
845
20.5
703.
067
22.0
562.
712
21.6
902.
784
-0.1
00.
5614
/02/
2007
05:
081.
830
0.03
350.
026
.084
21.7
662.
822
20.5
683.
044
22.0
492.
668
21.6
892.
752
0.00
0.56
14/0
2/20
07 0
7:08
1.83
00.
0335
0.0
25.9
7621
.772
2.81
320
.569
3.03
622
.053
2.66
121
.693
2.74
63.
100.
56A
vera
ges
1.83
00.
0335
0.0
26.1
0521
.775
2.82
820
.572
3.04
922
.055
2.67
521
.695
2.76
01.
660.
56
Dat
e &
Tim
eTo
tal
Surr
ound
Sur
face
Pow
erH
otC
old
Surf
ace
Air
tem
pera
ture
sEn
viro
nmen
tal t
empe
ratu
res
Baffl
e te
mpe
ratu
res
Ther
mal
Ther
mal
Surf
ace
Resi
stan
cepo
wer
Hot
Col
dth
roug
hsu
rfac
esu
rfac
eTe
mp
Hot
Col
ddi
ffH
otC
old
diff
Hot
Col
dC
ond
Tran
sH
otC
old
Cor
for
Inse
rtte
mp
tem
pdi
ffH
FM O
ffm
inus
BL%
(W)
(°C
)(°
C)
(W)
(°C
)(°
C)
(°C
)(°
C)
(°C
)(°
C)
(°C
)(°
C)
(°C
)(°
C)
(°C
)(W
/m².K
)(W
/m².K
)(m
².K/W
)(m
².K/W
)Bo
unda
ry lo
ss c
alc
usin
g TH
ERM
5A
rea
of sp
ecim
en1.
8296
m²
Thic
k @
edg
e 16
2.00
mm
Bou
nd L
oss
(W)
0.56
26-M
ar-0
7M
ean
envi
rn te
mp
12.2
5°C
Hr (
c)
5.77
2A
rea
hold
er
3.95
80m
²H
olde
r thi
ckne
ss0.
298
mλ
Hol
der
0.03
35W
/m.K
Hr (
h)4.
766
Efth
n/a
mm
Baffl
e Em
is. H
ot0.
94Sp
ec. E
mis
. Hot
0.9
Emis
sivi
ty F
acto
r H
ot0.
8511
Tot R
es0.
173
Baffl
e Em
is C
old
0.94
Spec
. Em
is. C
old
0.9
Emis
sivi
ty F
acto
r C
old
0.85
1113
/02/
2007
23:
0826
.172
21.7
862.
873
17.1
8620
.581
3.09
117
.490
22.0
622.
725
19.3
3721
.829
2.73
319
.095
21.7
042.
805
0.53
70.
492
0.13
30.
038
14/0
2/20
07 0
1:08
26.1
3421
.779
2.78
617
.113
20.5
723.
007
17.5
6622
.057
2.60
719
.450
21.8
212.
619
19.2
0321
.698
2.71
10.
532
0.48
70.
134
0.04
114
/02/
2007
03:
0826
.142
21.7
722.
845
17.1
4920
.570
3.06
717
.503
22.0
562.
712
19.3
4421
.817
2.71
919
.098
21.6
902.
784
0.53
60.
491
0.13
30.
037
14/0
2/20
07 0
5:08
26.0
8421
.766
2.82
217
.084
20.5
683.
044
17.5
2422
.049
2.66
819
.381
21.8
132.
677
19.1
3721
.689
2.75
20.
533
0.48
80.
133
0.03
914
/02/
2007
07:
0825
.965
21.7
722.
813
16.9
5820
.569
3.03
617
.533
22.0
532.
661
19.3
9221
.815
2.67
019
.145
21.6
932.
746
0.52
90.
484
0.13
40.
039
**
**
**
**
**
**
**
**
**
*
Av.
Val
ues
26.0
9921
.775
2.82
817
.098
20.5
723.
0517
.52
22.0
62.
6719
.38
21.8
22.
6819
.14
21.6
92.
760.
533
0.48
80.
133
0.03
9V
aria
tion
0.80
%0.
020
0.08
71.
34%
0.01
30.
084
0.43
%0.
013
0.11
80.
58%
0.01
50.
114
0.56
%0.
015
0.09
51.
58%
1.60
%0.
002
0.00
4
Surr
ound
tem
p di
ffere
nce
18.9
47°C
9.34
5W
/m2
Stan
dard
ised
U-v
alue
(to
0.17
m2 .K
/W)
0.48
9
Surr
ound
mea
n te
mpe
ratu
re12
.301
°C
Hol
der p
anel
num
ber
![Page 28: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/28.jpg)
NPL
Rep
ort M
AT
8 Pa
ge 2
2 of
36
Tab
le 5
Mea
sure
d an
d ca
lcul
ated
U-v
alue
s of t
he fo
ur in
sula
ted
roof
syst
ems.
Hot Box test number
NPL Specimen number
Description of test element
Heat flow direction
Environmental [1]
temperature difference (°C)
Measured standardised thermal
transmittance (W/m
2.K)
Calculated thermal transmittance -
(using THERM & ISO 15099) (W/m
2.K)
Assumptions made in calculating the U-value
1R
058A
Tris
o-Su
per 1
0 - V
ertic
al -
Air
vent
clo
sed
Hor
izon
tal
19.1
40.
489
2R
058B
Tris
o-Su
per 1
0 - 4
5 de
gree
s - A
ir ve
nt c
lose
dU
p19
.14
0.51
40.
533
R05
8DTr
iso-
Supe
r 10
- Hor
izon
tal -
Air
vent
clo
sed
Up
19.3
10.
529
4R
058E
Tris
o-Su
per 1
0 - 4
5 de
gree
s - A
ir ve
nt o
pen
Up
19.1
00.
559
5R
058F
Tris
o-Su
per 1
0 - H
oriz
onta
l - A
ir ve
nt c
lose
dD
own
19.0
00.
347
6R
059A
Cel
otex
- V
ertic
al -
Air
vent
clo
sed
Hor
izon
tal
19.3
30.
256
7R
059B
Cel
otex
- 45
deg
rees
- A
ir ve
nt c
lose
dU
p19
.33
0.26
00.
278
R05
9CC
elot
ex -
Hor
izon
tal -
Air
vent
clo
sed
Up
19.5
90.
261
9R
059D
Cel
otex
- 4
5 de
gree
s - A
ir ve
nt o
pen
Up
19.2
50.
269
10R
059E
Cel
otex
- H
oriz
onta
l - A
ir ve
nt c
lose
dD
own
19.1
20.
232
11R
060A
Air
cavi
ty -
Ver
tical
- A
ir ve
nt c
lose
dH
oriz
onta
l19
.31
0.33
412
R06
0BA
ir ca
vity
- 45
deg
rees
- A
ir ve
nt c
lose
dU
p19
.30
0.35
70.
3613
R06
0CA
ir ca
vity
- H
oriz
onta
l - A
ir ve
nt c
lose
dU
p19
.63
0.41
714
R06
0DA
ir ca
vity
- 4
5 de
gree
s - A
ir ve
nt o
pen
Up
19.3
60.
392
15R
060E
Air
cavi
ty -
Hor
izon
tal -
Air
vent
clo
sed
Dow
n19
.17
0.26
8
16R
061A
Gla
ss fi
bre
- 45
degr
ees -
Air
vent
clo
sed
Up
19.4
20.
333
0.35
17R
061B
Gla
ss fi
bre
- 45
deg
rees
- A
ir ve
nt o
pen
Up
19.3
80.
341
Not
e [1
]Fo
r the
def
initi
on o
f env
ironm
enta
l tem
pera
ture
s see
BS
EN IS
O 8
990
Ann
ex A
* Tr
iso-
Supe
r 10
assu
med
to b
e a
unifo
rm s
lab
of in
sula
tion
23 m
m
thic
k w
ith a
λ o
f 0.0
33 W
/m.K
*
It's
oute
r sur
face
s w
ere
assu
med
to
hav
e em
ittan
ces
of 0
.05
* Th
e em
ittan
ce o
f the
foil
cove
ring
of th
e in
sula
tion
was
as
sum
ed to
be
0.2.
* λof
the
insu
latio
n w
as a
ssum
ed
to b
e 0.
023
W/m
.K.
*
Th
ickn
ess
of th
e in
sula
tion
was
ta
ken
as 1
00 m
m
* Th
e em
ittan
ce o
f the
alu
min
ium
fo
il w
as a
sum
ed to
be
0.05
* λ
of th
e gl
ass
fibre
was
as
sum
ed to
be
0.03
4 W
/m.K
![Page 29: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/29.jpg)
Page 23 of 36 NPL Report MAT 8
5.4 U-values modelled using 2D Finite Element Analysis (FEA) As a cross check, the U-values (in the 45 degree orientation) of the roof sections that had been measured in the hot box were calculated. The thermal resistance of the air cavities were calculated using the procedures in ISO 15099 and the overall U-value of the roof structure was simulated using the 2D Finite Element Analysis software tool THERM5, produced by the Windows and Daylighting Group of the Lawrence Berkeley Laboratory in the USA. A number of assumptions had to be made and the most important of which are identified in Table 5. A manual, iterative method was used to ensure the air cavity thermal resistance value associated with the appropriate air cavity temperature difference was used in the 2D FEA model. An example of a THERM5 model can be seen in Figure 12. The results of the 2D Finite Element Modelling can be seen in Table 5. Figure 12 THERM Model of Roof section insulated with Triso-Super 10
6 Temperature cycling measurements carried out in a heat flow apparatus.
6.1 Description of apparatus and control system These measurements were carried out in a LaserComp FOX 600, 610 mm square, single specimen, Heat Flow Meter apparatus, using control and acquisition software specifically written by the manufacturer for this project. This apparatus incorporates 5 heat flux transducers on both surface plates and five associated temperature sensors to measure the plate temperatures. It conforms to the requirements of ISO 8301, EN 12667. A simple, schematic diagram of the apparatus can be seen in Figure 13. The special software allowed the following conditions to be imposed on the specimen:-
i. The temperature of one plate held constant and the other cycled, over a period of 24 hours, at temperatures always higher than that of the plate held constant.
ii. The temperature of one plate held constant and the other cycled, over a period of 24 hours, at temperatures that were both higher and lower than the one being held constant.
Plasterboard 12mm thickλ = 0.16 W/m.K assumed
Air cavity equivelent 0.043 mm deepλ = 0.16 W/m.K calculated using ISO 15099
Air cavity 0.083 mm deepEquivelent λ = 0.16 W/m.K calculated using ISO 15099
Triso-Super 10 average thickness estimated as 23 mm.λ = 0.033 W/m.K assumed
Wood 19 mm thickλ = 0.14 W/m.K assumed
Compressed Triso-Super 10 - 2mm deep λ = 0.04 W/m.K assumed
Membrane 1 mm thickλ = 0.2 Wm.K assumed
Wood 38 mm thick
![Page 30: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/30.jpg)
NPL Report MAT 8 Page 24 of 36
iii. The temperature of one plate held constant and the other cycled, over a period of 24 hours, at temperatures always lower than that of the plate that was held constant
During the measurements the instantaneous heat flux (W/m2) and temperature of the two central heat flux transducers were recorded approximately every 6 seconds.
Figure 13 Sketch of the LaserComp FOX 600 heat flow meter hot plate apparatus
6.2 Overview of specimens and measurements The thermal performance of a low density glass fibre insulation specimen (10 kg/m3) and an 85 mm deep air cavity insulated with Actis Triso-Super 10 installed centrally, were compared when the temperature of one of the bounding surfaces of the test sample was cycled as described in section 6.1. These measurements were carried out in the apparatus described in section 6.1. The plate temperatures and cycling regimes used for these measurements are also given in Table 6.
6.3 Heat flow meter steady state results. The results for these measurements can be seen in Table 6. The marked difference between the thermal resistance measured with heat flow up and down for the air cavity insulated with the Triso-Super 10 material is the most interesting feature of these results.
6.4 Heat flow meter temperature cycling measurements The results of these measurements can be seen in Figure 14, Figure 15, Figure 16, Figure 17, Figure 18 and Figure 19 and they are summarised in Table 6.
610 mm
Test sample
Peltier effect - heater/cooler
plate
Peltier effect - heater/cooler
plate Central heat flux tranducer
Central heat flux tranducer
305 mm
101 mm
90 mm
1 mm3 mm
Plate tranducers
![Page 31: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/31.jpg)
Page
25
of 3
6
NPL
Rep
ort M
AT
8
Tab
le 6
Res
ults
of t
he h
eat f
low
met
er a
ppar
atus
mea
sure
men
ts
Test number
Specimen description
Test description
Lower plate minimum temperature (°C)
Lower plate maximum temperature (°C)
Upper plate minimum temperature (°C)
Upper plate maximum temperature (°C)
Mean temperature (°C)
Temperature difference (°C)
Cycling temperature range (°C)
Average temperature difference across
specimen during cycling (°C)
Heat flow direction °C
Thermal resistance (m
2.K)/W
W.hrs in 24 hours
1G
lass
fibr
e
(0.
1m th
ick
& 10
kg/m
3 )S
tead
y st
ate
2020
00
1020
--
Up
2.19
2-
2G
lass
fibr
e
(0.
1m th
ick
& 10
kg/m
3 )S
tead
y st
ate
00
2020
1020
--
Dow
n2.
178
-3
Gla
ss fi
bre
(
0.1m
thic
k &
10kg
/m3 )
Stea
dy s
tate
3535
1515
2520
--
Up
1.98
5-
4G
lass
fibr
e
(0.
1m th
ick
& 10
kg/m
3 )St
eady
sta
te15
1535
3525
20-
-D
own
1.97
7-
5G
lass
fibr
e
(0.
1m th
ick
& 10
kg/m
3 )C
yclin
g25
250
20-
-20
15U
p-
1.75
6G
lass
fibr
e
(0.
1m th
ick
& 10
kg/m
3 )C
yclin
g25
2515
35-
-20
5U
p &
Dow
n-
1.36
7G
lass
fibr
e
(0.
1m th
ick
& 10
kg/m
3 )C
yclin
g25
2530
50-
-20
15D
own
--2
.03
8AC
TIS
Tris
o-S
uper
10
in 0
.085
m c
avity
Ste
ady
stat
e20
200
010
20-
Up
1.73
4-
9AC
TIS
Tris
o-S
uper
10
in 0
.085
m c
avity
Ste
ady
stat
e0
020
2010
20-
Dow
n2.
471
-10
AC
TIS
TriI
so S
uper
10
in 0
.085
m c
avity
Ste
ady
stat
e35
3515
1525
20-
Up
1.70
4-
11A
CTI
S T
riso-
Sup
er 1
0 in
0.0
85m
cav
ityS
tead
y st
ate
1515
3535
2520
-D
own
2.19
4-
12A
CTI
S T
riso-
Sup
er 1
0 in
0.0
85m
cav
ityC
yclin
g25
250
20-
-20
15U
p-
1.98
13A
CTI
S T
riso-
Sup
er 1
0 in
0.0
85m
cav
ityC
yclin
g25
2515
35-
-20
5U
p &
Dow
n-
1.20
14A
CTI
S T
riso-
Sup
er 1
0 in
0.0
85m
cav
ityC
yclin
g25
2530
50-
-20
15D
own
--1
.68
![Page 32: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/32.jpg)
NPL Report MAT 8 Page 26 of 36
Figure 14 Test 5 Cycling glass fibre – Mean temperature 10 °C ± 10 °C
Figure 15 Test 6 Cycling glass fibre -Mean temperature 25 °C ± 10 °C
Test 5 - Glass fibre blanket (nominal density 10 kg/m3) - Power & plate temperatures .
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0.18
0.2
0 12 24 36 48
Time / hours
Pow
er (h
eat f
low
UP)
/ W
-5
0
5
10
15
20
25
30
Plate temperatures / °C
Upper plate power Lower plate power Upper plate temperature Lower plate temperature
-0.1
-0.08
-0.06
-0.04
-0.02
0
0.02
0.04
0.06
0.08
0.1
0 12 24 36 48
Time / hours
Pow
er (h
eat f
low
up
& d
own)
/ W
10
15
20
25
30
35
40
45
50 Test 6 - Glass fibre blanket (nominal density 10 kg/m3) - Power & plate temperatures
Upper plate power Lower plate power Upper plate temperature Lower plate temperature
Plate temperatures / °C
![Page 33: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/33.jpg)
Page 27 of 36 NPL Report MAT 8
Figure 16 Test 7 Cycling glass fibre - Mean temperature 40 °C ± 10 °C
Figure 17 Test 12 Cycling Actis Triso-Super 10 - Mean temperature 10 °C ± 10 °C
-0.18
-0.16
-0.14
-0.12
-0.1
-0.08
-0.06
-0.04
-0.02
00 12 24 36 48
Time / hour
Pow
er (
heat
flow
dow
n) /
W
0
10
20
30
40
50
60
Test 7 - Glass fibre blanket (nominal density 10 kg/m3) - Power & plate temperatures
Plate temperatures / °C
Upper plate power Lower plate power Upper plate temperature Lower plate temperature
Test 12 - ACTIS Triso-Super 10 - Power and plate temperatures
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0.18
0.2
0 12 24 36 48
Time / hours
Pow
er (h
eat f
low
UP)
/ W
-5
0
5
10
15
20
25
30 Upper plate power Lower plate power Lower plate temperature Upper plate temperature
Plate temperatures °C
![Page 34: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/34.jpg)
NPL Report MAT 8 Page 28 of 36
Figure 18 Test 13 Cycling Actis Triso-Super 10 Mean temperature 25 °C ± 10 °C
Figure 19 Test 14 - Cycling Actis Triso-Super 10 Mean temperature 40 °C ± 10 °C
Test 13 - Triso-Super 10 - Power and plate temperatures
-0.1
-0.08
-0.06
-0.04
-0.02
0
0.02
0.04
0.06
0.08
0.1
0 12 24 36 48
Time /hour
Pow
er (h
eat f
low
UP
& D
OW
N) /
W
10
15
20
25
30
35
40
45
50
Plate temperature °C
Upper plate power Lower plate power Upper plate temp Lower plate temperature
Test 14 ACTIS Triso-Super 10 - Power and plate temperatures
-0.18
-0.16
-0.14
-0.12
-0.1
-0.08
-0.06
-0.04
-0.02
00 12 24 36 48
Time / hr
Pow
er (h
eat f
low
DO
WN
) / W
0
10
20
30
40
50
60
Plate temperatures (°C
)
Upper plate power Lower plate power Upper plate temperature Lower plate temperature
![Page 35: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/35.jpg)
Page 29 of 36 NPL Report MAT 8
7 Discussion of results
7.1 Hot Box results
7.1.1 The measured U-values The U-value results of the all the different roof systems are consistent with predictions of their thermal performance based on combining the various steady-state thermal resistances of the materials and air cavities, using well-established methodologies. The agreement between the measured U-values and those calculated using the convective correlations given in ISO 15099 to calculate the thermal resistance of unventilated air cavities, the thermal resistance of the various components and the two dimensional finite element analysis software tool THERM to combine them, support this conclusion. Those measured and calculated values are shown in Table 5.
7.1.2 The effect of direction of heat flow The size of the effect of the direction of heat flow on the measured U-value once again reflects the relative importance of the thermal resistance of the air cavities to the overall thermal resistance. The values given in Table 7 show the Actis Triso-Super 10 insulated roof behaving in a similar way to the roof insulated only with air cavities, whereas the roofs with the Celotex and Glass fibre show a smaller effect on U-value of the direction of heat flow. In circumstances where the roof is hotter than the inside of the building the systems employing large air cavities will have much improved thermal properties. The U-value of the Actis Triso-Super 10 insulated roof was about 36% lower (see Table 7) with downward heat flow which is the same as the improvement in thermal resistance of the air cavity insulated with Triso-Super 10 measured in the heat flow meter apparatus (see Table 8).
7.1.3 Effect of allowing air flow into the external air cavity The effect on the measured U-values of the small airflow induced into the outer cavity through 25 mm wide pierced metal strips fixed to the top and bottom of the roof structure, (see Figure 7) can also be seen in Table 7. It increased the U-value of the Tri-Iso Super 10 and the air cavity roof by about 9% and the Celotex and Glass Fibre insulated roofs by about 3% which again reflects the relative importance of that external air cavity to the overall thermal resistance of the system.
![Page 36: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/36.jpg)
NPL Report MAT 8 Page 30 of 36
Table 7 Effect on measured U-value of orientation; air infiltration; direction of heat flow
7.2 Heat Flow Meter measurements and the non-steady state results. The measured values are shown in Table 6 and a summary of the analysis carried out of these data care shown in Table 8. The energy used over a 24 hour period to cycle the glass fibre and Triso-Super 10 insulated air cavity was derived from the area under the curves shown in Figure 14, Figure 15, Figure 16, Figure 17, Figure 18 and Figure 19, using a graphical technique. The thermal resistance values of the 100 mm thick low-density glass fibre and the 85 mm thick, Triso-Super 10 insulated air cavity, are in good agreement with values measured previously both in the heat flow meter apparatus and the hot box. When the thermal resistance values measured at the same temperature, with upward heat flow and downward heat flow are normalised to the same temperature –(see Table 8), the thermal resistance of the glass fibre is shown to be independent of heat flow direction and the Actis Triso-Super 10 insulated air cavity to be strongly dependent on heat flow direction as expected.
Hot
Box
test
num
ber
NPL
Spe
cim
en n
umbe
r
Des
crip
tion
of te
st e
lem
ent
Hea
t flo
w d
irec
tion
Env
iron
men
tal [1
]
tem
pera
ture
diff
eren
ce
(°
C)
Mea
sure
d st
anda
rdis
ed
th
erm
al tr
ansm
ittan
ce
(W
/m2 .K
)
% d
iffer
ence
to th
e U
-val
ue
mea
sure
d w
ith
ho
rizo
ntal
hea
t flo
w.
% d
iffer
ence
res
ultin
g fr
om th
e sm
all a
ir fl
ow in
the
exte
rnal
air
ca
vity
.
%ch
ange
in U
-val
ue o
f ho
rizo
ntal
cav
ity w
ith
dow
nwar
ds fl
owin
g
he
at tr
ansf
er.
1 R058A Triso-Super 10 - Vertical - Air vent closed Horizontal 19.14 0.4892 R058B Triso-Super 10 - 45 degrees - Air vent closed Up 19.14 0.514 -5.13 R058D Triso-Super 10 - Horizontal - Air vent closed Up 19.31 0.529 -8.24 R058E Triso-Super 10 - 45 degrees - Air vent open Up 19.10 0.559 -8.8
5 R058F Triso-Super 10 - Horizontal - Air vent closed Down 19.00 0.347 29.0 34.4
6 R059A Celotex - Vertical - Air vent closed Horizontal 19.33 0.2567 R059B Celotex - 45 degrees - Air vent closed Up 19.33 0.260 -1.68 R059C Celotex - Horizontal - Air vent closed Up 19.59 0.261 -2.09 R059D Celotex - 45 degrees - Air vent open Up 19.25 0.269 -3.5
10 R059E Celotex - Horizontal - Air vent closed Down 19.12 0.232 9.4 11.1
11 R060A Air cavity - Vertical - Air vent closed Horizontal 19.31 0.33412 R060B Air cavity - 45 degrees - Air vent closed Up 19.30 0.357 -6.913 R060C Air cavity - Horizontal - Air vent closed Up 19.63 0.417 -24.914 R060D Air cavity - 45 degrees - Air vent open Up 19.36 0.392 -9.8
15 R060E Air cavity - Horizontal - Air vent closed Down 19.17 0.268 19.8 35.7
16 R061A Glass fibre - 45 degrees - Air vent closed Up 19.42 0.33317 R061B Glass fibre - 45 degrees - Air vent open Up 19.38 0.341 -2.4
![Page 37: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/37.jpg)
Page 31 of 36 NPL Report MAT 8
The energy used to cycle these systems over a 24 hour period will be dependent on: i. Temperature difference
ii. Mass iii. Thermal resistance (which is dependent on mean temperature for both systems and
the temperature difference for the Triso-Super 10 insulated air cavity). iv. Specific heat.
To compare how these two subsystems are behaving dynamically, the thermal resistance at the “mean” temperature of the cycled samples has had to be derived from the measured steady state values for both materials for both the only heat flow up and only heat flow down situations. See Table 8. The figures in this table show that for heat flow up, at a mean temperature of 17.5 °C, the thermal resistance of the glass fibre specimen is 18% higher than the Tri-Iso Super 10 insulated air cavity, however, the Watt hours used over 24 hours was only 13% less for the glass fibre sample than for the Triso-Super 10. This small discrepancy could be related to the fact that the thermal resistance of an insulated air cavity will increase (non-linearly) as the temperature difference across it gets smaller and that the minimum temperature difference in this case is 5°C. The figures in this table also show that for the heat flow down situation, at a mean temperature of 32.5°C, that while the thermal resistance of the glass fibre specimen is 10% lower than for the Triso-Super 10 insulated air cavity, the Watt hours used over 24 hours was 17% more for the glass fibre sample. This discrepancy could again be related to the fact that the thermal resistance of an insulated air cavity increases (non-linearly) as the temperature difference across it gets smaller. The minimum temperature difference in this case is again 5°C. The graphs for the situation where the upper plate was cycled above and below the temperature of the fixed temperature plate highlight the asymmetrical nature of the air cavity thermal resistance. With the glass fibre sample (Figure 14) the Watts against time curve is symmetrical around 0 watts. For the Triso-Super 10 insulated air cavity (Figure 15) it can be seen that more power is being transferred on the heat-flow-up cycle than for the heat-flow-down-cycle. There are a number of interesting features of the graphs plotted for the temperature cycling data that have not yet been analysed. These are: • Phase difference between the power entering and leaving the upper and lower
heater/cooler plates. • Amplitude difference between the power entering and leaving the upper and lower
heater/cooler plates. • The periods of erratic power flows exhibited by some of the graphs could be
associated with the onset of convection.
![Page 38: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/38.jpg)
NPL Report MAT 8 Page 32 of 36
Table 8 Analysis of the heat flow meter apparatus measurements
Glass fibre (100 mm thick ~ 10 kg/m3)Thermal resistance at mean temperature 10 °C heat flow UP (measured - steady state) 2.192 m2.K/WThermal resistance at mean temperature 25°C heat flow UP (measured - steady state) 1.985 m2.K/WThermal resistance at mean temperature 17 °C heat flow UP (Interpolated - steady state) 2.095 m2.K/WThermal resistance at mean temperature 10 °C heat flow DOWN (measured - steady state) 2.178 m2.K/WThermal resistance at mean temperature 25°C heat flow DOWN (measured - steady state) 1.977 m2.K/WThermal resistance at mean temperature 32°C heat flow DOWN (extrapolated - steady state) 1.883 m2.K/WThermal resistance at mean temperature 17°C heat flow DOWN (interpolated - steady state) 2.084 m2.K/W% difference between (R @ 17 °C HF UP & R @ 17°C HF DOWN)/ (R @ 17 °C HF UP) 0.5 %(W.hr in 24 hours) - mean temp ~ 17 °C heat flow UP (Measured - temperature cycling) 1.75 W.hr(W.hr in 24 hours) - mean temp ~ 32 °C heat flow DOWN (Measured - temperature cycling) 2.03 W.hr
Tri-Iso Super 10 in centre of a 85 mm deep air cavityThermal resistance at mean temperature 10 °C heat flow UP (measured - steady state) 1.734 m2.K/WThermal resistance at mean temperature 25°C heat flow UP (measured - steady state) 1.704 m2.K/WThermal resistance at mean temperature 17 °C heat flow UP (Interpolated - steady state) 1.720 m2.K/WThermal resistance at mean temperature 10 °C heat flow DOWN (measured - steady state) 2.471 m2.K/WThermal resistance at mean temperature 25°C heat flow DOWN (measured - steady state) 2.194 m2.K/WThermal resistance at mean temperature 32°C heat flow DOWN (extrapolated - steady state) 2.065 m2.K/WThermal resistance at mean temperature 17°C heat flow DOWN (interpolated - steady state) 2.342 m2.K/W% difference between (R @ 17 °C HF UP - R @ 17 °C HF DOWN)/R @ 17 °C HF UP -36.1 %
(W.hr) - mean temp ~ 17 °C heat flow UP 1.98 W.hr(W.hr) - mean temp ~ 32 °C heat flow Down 1.68 W.hr
Relationship between Thermal resistance and Energy used to cycle test elements over a 24 hour period
Mean temperature 17 °C HF UP - ((R glass fibre - R Tri-Iso)/ Rglass fibre) 18 %Mean temperature 17 °C HF UP - ((W.hr glass fibre - W.hr Tri-Iso)/ W.hr glass fibre) -13 %
Mean temperature 32°C HF DOWN - ((R glass fibre - R Tri-Iso)/ Rglass fibre) -10 %Mean temperature 32°C HF DOWN - ((W.hr glass fibre - W.hr Tri-Iso)/ W.hr glass fibre) 17 %
![Page 39: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/39.jpg)
Page 33 of 36 NPL Report MAT 8
8 Summary of project and conclusions
8.1 Summary of project a) The U-values of a representative roof section insulated with four different insulation
systems have been measured in the NPL rotatable hot-box facility. The insulation systems tested were: • Actis Triso-Super 10 • Celotex TUFF-RTM GA 3050 rigid polyisocyanurate foam • Glass fibre Knauf Rafer Roll 32 • Reflective air cavities formed by 2 mm cardboard covered on both sides with
aluminium foil. b) The U-value measurements were carried out in the following orientations:
• Test element vertical - Horizontal heat flow - Air vent closed • Test element @ 45 degrees - Heat flow up - Air vent closed • Test element @ 45 degrees - Heat flow up - Air vent open • Test element horizontal - Heat flow up - Air vent closed • Test element horizontal - heat flow down - Air vent closed
c) The U-value of each of the roof structures in the 45 degree orientation, were also
calculated using the thermal conductivity data of the materials, the procedures in BS ISO 15099 to derive air cavity thermal resistances and the Lawrence Berkeley Laboratory 2D FEA software - THERM5.
d) Steady state thermal resistance measurements and temperature cycling, energy consumption measurements were carried out in a LaserComp FOX 600, a 610 mm square, single specimen, Heat Flow Meter (HFM) apparatus, using special control and acquisition software written by the manufacturer for this project. The measurements were carried out on two specimens: • 100 mm thick glass fibre (10 kg/m3) • 85 mm deep air cavity with a layer of Actis Triso-Super 10 material fixed in the centre
of the cavity.
The HFM apparatus measurements carried out were:
Steady state thermal resistance measurements: i) Mean temperature 10 °C with heat flow up.
ii) Mean temperature 10 °C with heat flow down iii) Mean temperature 25 °C with heat flow up. iv) Mean temperature 25 °C with heat flow down
Thermal cycling measurements.
v) Lower surface constant 25 °C upper surface 10 °C ± 10 °C vi) Lower surface constant 25 °C upper surface 25 °C ± 10 °C
vii) Lower surface constant 25 °C upper surface 40 °C ± 10 °C
![Page 40: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/40.jpg)
NPL Report MAT 8 Page 34 of 36
e) Brief explanations of the following were given: i) The role of the three modes of heat transfer in the roof structures.
ii) Factors that effect the thermal resistance of air cavities. f) The various methods that could be used to quantify the thermal performance of insulation
systems based on the use of reflective surfaces are discussed (Section 3).
8.2 Conclusions 1) The mechanisms by which reflective surfaces increase the thermal resistance of air
cavities are well understood.
• The use of low emittance surfaces to increase the thermal resistance of air cavities has a long history (Sir James Dewar’s vacuum flask in 1882).
• There are many “standard” methods of calculating the thermal resistance of air cavities that have one or more reflective surfaces from measured emittance values, temperature difference across the cavity, mean temperature and cavity orientation. These include BS EN 673, BS ISO 15099, BS EN ISO 6946 and the ASHRAE Book of Fundamentals).
2) The hot-box apparatus is capable of measuring the overall heat transfer through non-
homogeneous structures that involve all three modes of heat transfer. Traditionally the thermal conductivity (W/m.K) of a homogeneous material (e.g. expanded polystyrene) is measured in a hot-plate apparatus[Note 1]. From the thermal conductivity value, various other thermal properties (e.g. thermal conductance, thermal resistance and U-value can be calculated using the thickness and standard surface heat transfer coefficients. The purpose of a hot box apparatus[Note 1] is to measure the overall heat transfer through non-homogeneous structures by measuring the temperature difference between the environments on either side of the structure, it’s area and the heat flow through it. The limitations of the hot-box method are as follows:
• It is not intended to quantify the effect of mass transfer (air infiltration). The thermal effect of air infiltration is traditionally determined by measuring the air infiltration rate through the structure and calculating the thermal effect of that airflow rate.
• It does not account for the effect of solar gain (e.g. through glazing) The suitability of the hot-box apparatus to measure the thermal transmittance of structures insulated with all types of insulation has been demonstrated by the good agreement between the measured U-values of the roof structures and those calculated using typical material property data, air cavity thermal resistances calculated using BS ISO 15099 and a assumed low emittance and the 2D FEA software tool THERM. Note[1] – Despite their similar sounding names, hot plate and hot-box apparatus are very different. A hot-plate apparatus (either guarded hot-plate or heat flow meter {HFM} hot-plate apparatus) measures the surface temperature difference across and the heat flow through, homogeneous samples measuring typically about 0.6 m x 0.6 m x 0.02 m to 0.2 m thick. A hot-box apparatus, however, measures the overall heat transfer, from the warm environment to the cold environment, through large, non-homogeneous structures. Specimens up to 2 m x 2 m x 0.3 m can be measured in the NPL facility – but apparatus exist that can measure even larger test elements
![Page 41: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/41.jpg)
Page 35 of 36 NPL Report MAT 8
Those measured and calculated U-values have been extracted from Table 5 and summarised in Table 9 below which shows the calculated values between 0 and 5% higher than the measured. It should be specially noted that one of these structures was insulated by a method that solely comprised air cavities and reflective surfaces. Table 9 Comparison between measured and calculated U-values
3) No significant thermal advantage was observed for the insulated air cavity over the low-
density glass fibre specimen during the temperature cycling measurements. Dynamic thermal measurements of an air cavity insulated with Actis Triso-Super 10 and a 100 mm thick, low density glass fibre specimen, showed the power required to cycle their temperatures over a 24 hour period were within ± 17% of each other, depending on direction of heat flow, with much of the difference being explained by differences in the thermal resistance at the average temperature of the sample during the cycling measurements. (See Table 8). 4) The hot box is the most effective method of determining the thermal resistance of air
cavities insulated with non-geometrically regular, reflective insulation Because of the difficulty of measuring the thermal resistance of non-geometrically regular products in a hot plate apparatus and difficulty in measuring the emittance of low emittance (often non-planar) surfaces it is concluded that the most effective method of determining the
NPL
Spe
cim
en n
umbe
r
Des
crip
tion
of in
sula
tion
used
in th
e ro
of st
ruct
ure.
All
mea
sure
men
ts
- A
ir v
ent c
lose
d
- Spe
cim
en a
t 45
degr
ees.
Hea
t flo
w d
irec
tion
Mea
sure
d
stan
dard
ised
ther
mal
tr
ansm
ittan
ce
(W
/m2 .K
)
Cal
cula
ted
th
erm
al tr
ansm
ittan
ce -
(u
sing
TH
ER
M &
ISO
150
99)
(W/m
2 .K) [1
]
Ass
umpt
ions
mad
e in
calc
ulat
ing
the
U-v
alue
R058B Triso-Super 10 Up 0.51 0.53* Triso Super 10 product assumed to be a uniform slab of insulation 23 mm thick * It's outer surfaces assumed to have an emittance of 0.05
R059B Celotex Up 0.26 0.27
* The emittance of the foil covering of the insulation assumed to have an emittance of 0.2; a the thermal conductivity of the insulation to be 0.023 W/m.K. and the thickness of the insulation was 100 mm
R060B Air cavities only Up 0.36 0.36 * The emittance of the aluminium foil was assumed to be 0.05
R061A Glass fibre Up 0.33 0.35 * The thermal conductivity of the glass fibre was assumed to be 0.034 W/m.K
![Page 42: NPL REPORT MAT 8 Evaluation of the thermal performance of ...eprintspublications.npl.co.uk/4044/1/MAT8.pdf · downward heat flow. The measurement at forty-five degrees was repeated](https://reader033.fdocuments.us/reader033/viewer/2022042013/5e73181df4704c7c4d11b96f/html5/thumbnails/42.jpg)
NPL Report MAT 8 Page 36 of 36
thermal resistance of an air cavity, insulated with such products, is to measure the thermal resistance of the insulated air cavity using the hot-box apparatus. 5) The thermal resistance of structures with deep (> 20 mm) air cavities will be dependent on
temperature difference and heat flow direction. When the hot environment is above the cold environment there is a significant improvement air cavity thermal resistance. This is illustrated by the improvement in the measured U-values of the Triso-Super 10 insulated roof and the roof insulated only with air layers when the heat-flow was downward (see the results in Table 5). It should be noted, however, that the thermal resistance of air cavities would decrease when the temperature difference across them increases (see Table 1). This effect will be important when the thermal performance of a structure depends mainly on the thermal resistance of air cavities. 6) Possible reasons for the large differences between the thermal performance values
measured with the standard measurement methods and the comparative measurement methods.
i) Are comparative methods sensitive enough to discriminate between products? It is important to determine if the method of comparing the power used to keep two roof-shaped structures, insulated with different products, exposed to the fluctuating outdoor climate, at the same internal temperature, is sensitive enough to discriminate between the thermal properties of the insulation materials being compared. To determine if a method is able to discriminate between products, a sensitivity analysis of the thermal system should be carried out to determine:-
• What percentage of the energy used, goes through the floor, end walls and the cold bridging constructions (i.e. rafters)?
• What percentage of the measured energy (over a given period of time) goes into changing the temperature of the structure?
• What percentage of energy is lost through heating up the air infiltrating into the structure?
• Identifying these parameters will enable the percentage of the measured energy that goes through the product being characterised to be determined.
Some suggestions of how to identify the cause of these differences are given in Section 3.5.
ii) Can a straightforward comparison of energy used to keep a special structure at a given temperature, while exposed to the outdoor climate, be used to compare products?
Extracting the thermal performance data for a specific component of a structure from the total energy required to keep that structure at a constant temperature when exposed to a real fluctuating climate is very complex. The EU PASSYS Project is an example of how this has been attempted in the past and is a good illustration of how complex that process is.[Note 2]
[Note 2] “Experience from PASSYS and the use of MRQT” – D.van Dijk – EU Commission Joint Research Centre publication – System identification applied to building performance data.