NOTE: MODIFY BOX CONSTRAINTS AS NEEDED PER ......Wire Strippers Mounting Clips (B) Angled Gimbal 6.5...
Transcript of NOTE: MODIFY BOX CONSTRAINTS AS NEEDED PER ......Wire Strippers Mounting Clips (B) Angled Gimbal 6.5...
Black White Green Grey Purple
Line Neutral Ground Dimming- Dimming+
Power Supply
Black (L)
White (N)
Purple (+)
Gray (-)
(+)
(-)
LED lightengine
2B
Step 2: Determine mounting position, adjust width of Hangers (A) until flush with surface.
2A- Anchor clips into wood joists with hammer and lock hangers.
OR 2B- Secure angle bars with screws to ceiling grid and lock hangers.
2B
Step 2: Determine mounting position, adjust width of Hangers (A) until flush with surface.
2A- Anchor clips into wood joists with hammer and lock hangers.
OR 2B- Secure angle bars with screws to ceiling grid and lock hangers.
(Top of housing hiddenfor clarity)
A
2
3
3.2
7
10"
7 -
1/2"
10"
25" Max 14" Min
(A) Hangers
ConstructionPlate (B)
Junction Plate (1) Driver Plate (1)
(C) Remote Driver
5
6- Pinch spring legs up and insertdownlight into recess
6
Downlight (1)
4
4- Remove driver and connecthigh voltage lines into driver.Do not disconnect low voltage wires. Replace driver.
High voltage In
Low voltage Out 4 - 5/8"
8 - 9/16"
18 - 1/4"
13
- 3/4
"
7"
B
B
C
B
(Top of housing hidden
for clarity)
A
B
2B
Step 2: Determine mounting position, adjust width of Hangers (A) until flush with surface.
2A- Anchor clips into wood joists with hammer and lock hangers.
OR 2B- Secure angle bars with screws to ceiling grid and lock hangers.
(Top of housing hiddenfor clarity)
A
8 - 9/16"
18 - 1/4"
14
- 3/4
"
7"
NO
TE: M
ODI
FY B
OX
CO
NST
RAIN
TS A
S N
EEDE
D PE
R DR
AW
ING N
OTE: M
ODIFY BO
X CO
NSTRA
INTS A
S NEEDED PER DRA
WIN
G
1
2A
Step 3: Install your Remote Driver (C) and pullDC Power through the knockout into the Housing (B).
Essential Hardware
Mounting Hardware
4- Connect male and femaleconnectors together
5- Connect spacer to downlight body
Various adapter plates are ordered with corresponding downlights, please refer to downlight data sheets
Step 5: Cut ceiling hole that matches the position anddimensions of the Construction Plate (B) hole.
Or
Wire Cutters
Hammer
#2 Screwdriver
Step 4: Install the ceiling. Make sure that theHousing (B) is flat on top of the ceiling.
Step 6: Install product (refer to ProductInstallation Instructions on back).
Bottom View
Bezel 100 RoundDownlight (D)
4 - 3/4" Hole Saw
Ceiling Saw
Hole Saw
Or
4
Conduit by others
Housing (B)
5
6
Hangers can attach to 2 sidesof the construction plate as
shown below.
Step 1: Attach the Hangars (A) to theCP/IC Housing (B).
(Top of Housing hidden for clarity)
(Top of Housing hidden for clarity) (Top of Housing hidden for clarity)
A
(Top of housing hiddenfor clarity)
1
TURN OFF MAIN POWER BEFORE PROCEEDING!
A(in) 3.9 4.5 4.8 5 6
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Inter-lux. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF Inter-lux IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONALANGULAR: MACH ± 0.5 BEND ± 1.0ONE PLACE DECIMAL ± 0.05
TWO PLACE DECIMAL ± 0.01
THREE PLACE DECIMAL ± 0.005
FINISH: GALVANIZED STEEL
SHEET 1 OF 3DRAWING NOT TO SCALE
Chicago Plenum/Insulated Ceiling Housing
REV N/C
WARNING:FAILURE TO COMPLY WITH THE
INSTALLATION INSTRUCTIONS MAYRESULT IN DEATH OR SERIOUS INJURY.
WARNING:INSTALL PRODUCT IN ACCORDANCE
WITH LOCAL AND NATIONAL ELECTRICALCODES; BY A QUALIFIED ELECTRICIAN.
CAUTION:INTER-LUX IS NOT RESPONSIBLE FOR THE
STRUCTURAL INTEGRITY OF THE BUILDING TOSUPPORT THE LUMINAIRE. ADDITIONAL BACKING
MAY BE REQUIRED.
*Inter-lux reserves the right to make changes to this product and related installation instructions at any time without prior notice.
WIRING DETAILS
Adapter Rings
ISOMETRIC VIEWS ITEMS NEEDED (SUPPLIED BY OTHERS):PACKAGE INCLUDES:
INSTALLATION INSTRUCTIONS
3RD ANGLEPROJECTION
Phone: (410)381-1497 Web: www.inter-lux.com
CAUTION:THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN
DURING STORAGE AND HANDLING. STORE IN A CLEAN, COOLAND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN
HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILEHANDLING THIS PRODUCT.
MOUNTING DIMENSIONS
WARNING:READ ALL SAFETY INSTRUCTIONS
INCLUDED WITH LUMINAIRE BEFOREINSTALLING LUMINAIRE.
MOUNTING OPTIONS
SURFACE MOUNT INSTALLATION STEPS
MOUNTING POSITIONS PRODUCT
PART. NO. CP/IC-WG-P100RAG-X
940-P100RAG
6 -
1/2"
1
2
C
1 -
3/4"
4 - 1/4"
14"
6 -
3/8"
3 -
3/8"
4 - 1/2"
6 -
3/8"
7 - 1/4"
B
(Ceiling hidden for clarity)
B
Plaster Applied
A A DA
B
D
(C) Mounting Clips
Step 4B: Before placement into the ceiling, push large Mounting Clips (B) into their slots
up to the first tab. Then insert Housing (B) into the ceiling and bring Mounting Clips (C) up
and into their respective slots as shown.Make sure that each clip is pushed until the
housing is secure in the ceiling.
Driver Box (A)
Light Engine (D)
(A) Housing
Philips Head#2 Screwdriver
Wire Connectors
Wire StrippersMounting Clips (B)
Angled Gimbal
6.5 inch Minimum Void Depth
Step 4b: Bring Mounting Clips (C) upthrough the Housing (B)(1) and push
them into their respective slots asshown (2). Make sure that each clip
is pushed down far enough thatthe fixture is secure in the ceiling.
Step 5: Once Housing (B) is flush with the ceiling and screwed down, plaster over the lattice.
Step 3: Pull DC Power wires and Dimming Leads through Housing (B).
(Ceiling)
Screw (x4)
Regressed Diffuser
Ceiling Saw
(Ceiling hidden for clarity) (Ceiling hidden for clarity)
(CP/IC Housing hidden for clarity) (CP/IC Housing hidden for clarity) (CP/IC Housing hidden for clarity) (CP/IC Housing hidden for clarity)
Step 2: Locate the DC Power wires. Thenpull them through the hole in the
Plenum Box and ceiling.
TURN OFF MAIN POWER BEFORE PROCEEDING!
Step 1: Complete up to and includng step 5 ofthe Chicago Plenum Surface Mount Install Steps.(Refer to Ceiling Thickness Key before installing)
Step 6: Attach the Safety Cable to the Light Engine (E)(1). Then make the connection
between the Driver (A) and the Light Engine (E) using the supplied connectors (2).
Step 7: Push the Light Engine (E) up into the Housing (B) until it locks into the spring latch. Tilt light into desired position (max 30 degree tilt).
Step 4A: Position the Housing (B) into hole and push it all the way in. Screw down the Housing
(B) into the ceiling using holes in the lattice.
1
2
Ceiling Thickness KeyMaterial Wood Gypsum Metal Tile
Minimum 1/4" 1/2" 1/16" 1/2"
Maximum 1" 1" 11/16" 1"
6 -
1/2"
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Inter-lux. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF Inter-lux IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
FINISH: WHITE PART. NO. WG-P100RAG22
SHEET 2 OF 3DRAWING NOT TO SCALE
MOUNTING INSTALLATION STEPS
REV N/C
WARNING:FAILURE TO COMPLY WITH THE
INSTALLATION INSTRUCTIONS MAYRESULT IN DEATH OR SERIOUS INJURY.
CAUTION:INTER-LUX IS NOT RESPONSIBLE FOR THE
STRUCTURAL INTEGRITY OF THE BUILDING TOSUPPORT THE LUMINAIRE. ADDITIONAL BACKING
MAY BE REQUIRED.
*Inter-lux reserves the right to make changes to this product and related installation instructions at any time without prior notice.
MOUNTING OPTIONS
ISOMETRIC VIEWS ITEMS NEEDED (SUPPLIED BY OTHERS):PACKAGE INCLUDES:
INSTALLATION INSTRUCTIONS
Phone: (410)381-1497 Web: www.inter-lux.com
CAUTION:THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN
DURING STORAGE AND HANDLING. STORE IN A CLEAN, COOLAND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN
HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILEHANDLING THIS PRODUCT.
MOUNTING DIMENSIONS
WARNING:READ ALL SAFETY INSTRUCTIONS
INCLUDED WITH LUMINAIRE BEFOREINSTALLING LUMINAIRE.
DIFFUSER POSITIONS
WARNING:INSTALL PRODUCT IN ACCORDANCE
WITH LOCAL AND NATIONAL ELECTRICALCODES; BY A QUALIFIED ELECTRICIAN.
Whitegoods Plaster 100 RoundAngled Gimbal 22
940-P100RAG
Red Black Green Black White
Positive Negative Ground Line Neutral
Purple Grey
Dimming + Dimming -
118'
72'
150'
200'100'
15'
25'
40'
60'
50'
35'
30'
#12AWG
#14AWG
#16AWG
#18AWG710 mA to 1.50 A200 mA to 700 mA
Wire Gauge EldoLEDLutron
Maximum Lead Length
118'
72'
150'
200'100'
15'
25'
40'
60'
50'
35'
30'
#12AWG
#14AWG
#16AWG
#18AWG710 mA to 1.50 A200 mA to 700 mA
Wire Gauge EldoLEDLutron
Maximum Lead Length
Standard Non-Dimming/DFPN Dimming D3W 1% Dimming
DES 1% Dimming 0-10V Dimming
To L
ine
Vol
tage
(Sta
ndar
d)
To F
orw
ard
Pha
se C
ontro
l (D
FPN
)
To 3
-Wire
Dim
min
g C
ontro
lTo
Lin
eV
olta
ge
To L
ine
Vol
tage
To E
cosy
stem
Dig
ital L
ink
To 0
-10V
Dim
Con
trol
NOTE: SHOWN DRIVERS ARE INTER-LUX PROVIDED. FOR NON INTER-LUX PROVIDED DRIVERS PLEASE REFER TODRIVER MANUFACTURER. THE USE OF NON INTER-LUX PROVIDED DRIVERS VOIDS PRODUCT WARRANTY.
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF Inter-lux. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF Inter-lux IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL SHEET 3 OF 3DRAWING NOT TO SCALE
Driver Wiring Diagrams
REV N/C
WARNING:FAILURE TO COMPLY WITH THE
INSTALLATION INSTRUCTIONS MAYRESULT IN DEATH OR SERIOUS INJURY.
WARNING:INSTALL PRODUCT IN ACCORDANCE
WITH LOCAL AND NATIONAL ELECTRICALCODES; BY A QUALIFIED ELECTRICIAN.
CAUTION:INTER-LUX IS NOT RESPONSIBLE FOR THE
STRUCTURAL INTEGRITY OF THE BUILDING TOSUPPORT THE LUMINAIRE. ADDITIONAL BACKING
MAY BE REQUIRED.
*Inter-lux reserves the right to make changes to this product and related installation instructions at any time without prior notice.
MAXIMUM NUMBER OF FIXTURES PER DRIVER
Phone: (410)381-1497 Web: www.inter-lux.com
CAUTION:THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN
DURING STORAGE AND HANDLING. STORE IN A CLEAN, COOLAND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN
HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILEHANDLING THIS PRODUCT.
WIRE GAUGES BY DISTANCE
WARNING:READ ALL SAFETY INSTRUCTIONS
INCLUDED WITH LUMINAIRE BEFOREINSTALLING LUMINAIRE.
*Actual Voltage drop to be calculated by installer
Wiring Key
Ground (Green)
Negative -Positive +
- Dimming+ Dimming
Ground
LineNeutral
Positive + (Red)
Negative - (Black)
Dimming + (Purple)
Dimming - (Grey)
Line (Black)
Neutral (White)
Fixture
Driver (Typical)
Switch/Dimmer
AC Power
Ground (Green)
Power Supply
Dimmed Hot (Black)
Neutral (White)+VDC (Red or Brown)
-VDC (Black or Blue)
LED lightengine
Ground (Green)
Power Supply
Switched Hot (Black)
Neutral (White) LED lightengine
Dimmed Hot (Orange)
Ground (Green) Power Supply
Switched Hot (Black)
Neutral (White)
LED lightengine
E1 (Purple)E2 (Purple)
Ground (Green) Power Supply
Line (Black)
Neutral (White)
Dimming + (Purple)
Dimming - (Grey)
LED lightengine
+VDC (Red or Brown)
-VDC (Black or Blue)
-VDC (Black or Blue) -VDC (Black or Blue)
+VDC (Red or Brown) +VDC (Red or Brown)
Wiring Instructions PART. NO. CP/IC-WG-P100RAG-X
*Actual Voltage drop to be calculated by installer
WIRE GAUGES BY DISTANCE
940-P100RAG