Norms for Educational building
Dr. Saravanan KAssociate professor
School of Mechanical and Building SciencesVIT Chennai
Occupant Load
Plinth level of the main building should be above 45 cm with respect
to average road level from site
Level of the Interior Courtyards, Covered Parking Spaces and
Garages should be above 15 cm with respect to average road level
from site
1. Provided that the minimum clear head way under any beam shall be not less than 2.4 m.
2. Maximum height permissible for all the components of the building mentioned above is 4 m.
3. The maximum height of building shall not exceed 1.5 times the width of road abutting plus the front open spaces.
Minimum Size and Width of Different Components of Residential Premises
Minimum Size and Width of Different Components of Residential Premises
Minimum Width Provisions for Stairways
The following minimum width provisions shall be made for each stairway
a) i) Residential low rise building 0.9 m. ii) Other residential building e.g. flats, hostels, group housing, guest houses, etc 1.25 m.
b) Assembly buildings like Auditorium, theatres and cinemas 2.0 m.
c) All other buildings including hotels 1.5 m.
d) Institutional building like hospitals 2.0 m.
e) Educational building like School, Colleges. 1.5 m.
Minimum Width Provisions for Stairways
The minimum width of treads : > 25 cm for residential building
: > 30 cm for others building
The maximum height of rise : <19 cm. for residential building
: < 15 cm for other building
Minimum height of handrails : >100 cm
Maximum no. rise per flight : < 12
Minimum Width Provisions for Passageway/Corridors
The following minimum width provisions shall be made for each passage way/corridor.
a) Residential buildings, dwelling unit type 1.0 m.
b) Residential buildings, e.g., hostels, etc. 1.25 m.
c) Assembly buildings like auditorium theatres and cinemas 2.0 m.
d) All other buildings including hotels 1.5 m.
e) Hospital, Nursing Homes, etc. 2.4 m.
Metro: Mumbai, Chennai, Kolkata, Delhi, Bangalore, Hyderabad, Ahmedabad, Kanpur and Pune
Class room size
Minimum one number drawing hall of size 175 sq.m upto 240 students in first yearMinimum two number drawing hall of size 175 sq.m more than 240 students
Class Room
Number of classrooms required for the college shall be equal to
Number of tutorial rooms required for the college shall be equal to
Total sanctioned intake for all the years x 0.7560
Total sanctioned intake for all the years x 0.560
Class room size
Carpet area in sq. mClass room 66Tutorial room 33Laboratory 66Research laboratory 66Seminar hall 132Library with reading room 400
Laboratories Size
For batch size of 30 students = 250 sq. m
For batch size of 40 students = 360 sq. m
Minimum area for workshop = 900 sq. m
Lab area does not include any faculty cabin inside the lab
Lab area includes the supporting staff and students sitting area
Lab area includes storage of consumable and instruments
Space in the Department
Carpet Area (Sq. m.)Head of Department 20Department Office 25Faculty rooms 10Library (Departmental) 30Seminar Room 30Store 10Drawing/Reprograp. Facilities 20
Space for Administrative Office
Carpet area (Sq. m.)
Principal’s office 30
Strong Room 20
Conference room 100
Reception office 25
Main office 300( for an intake of 240 students per year)
Administrative office 20
Maintenance & Estate office 40
Toilet Blocks
Education Building : 10 sq.m. for each unit of 100 students
Hostel : 75 sq.m. for each unit of 120 students
Norms for Hostels
College is located within 20 km. of a large city: Accommodation for 20% of bays and 50 % of girls on enrollment
Other locations : Accommodation for 50% of bays and 100 % of girls on enrollment
Carpet area (sq.m)Single room 9Triple seated room 20