noris product catalog 2017 web - cpmpharma.pt · Table of Contents / 2 / Implants Company Profile...
Transcript of noris product catalog 2017 web - cpmpharma.pt · Table of Contents / 2 / Implants Company Profile...
/ 1 /
PRODUCT CATALOG
Personal AttentionAccurate Dental Solutions
PrecisionDown to the Smallest Detail
Wide Range of Dental SolutionsEngineerd for a Lifetime
Global Partners
/ 1 /
Company Profile 2-4
Implants Implants Index 6-7Tuff 8-9Tuff Pro 10-11Tuff TT 12-13Onyx 14-15Cortical 16-17PteryCore 18PteryFit 19Pterygoid Implants Tools 21Zygomatic 22-25MBI & MBI NC 26-27Mono 28-29Packaging 30
Prosthetics Prosthetic Workflow 32-33Accessories Healing Caps 34Open & Closed Tray Transfers 35Snap-On Transfer 36Clip-On Transfer 37Cement Retained Restorations Temporary Abutments 38-39Straight Abutments 40-41Angulated Abutments 42-43Titanium Base Zirconia Abutments 44Castable Abutments 45CAD/CAM Abutments 46-47Screw Retained RestorationsMulti-Unit - Straight & Angulated 50Multi-Unit Components 52-53Multi-Unit Protocol 54-55Esthetic Screw Abutment 56Removable Restorations Vari-Connect 58Vari-Connect Components 59Ball Attachment 60Flat Attachment 61Noris Lock 62
InstrumentsDrills Workflow 64Drills 65-68Drivers 69-71Tools 72-73Kits 74-76
Table of Contents
/ 2 / Implants
Company ProfileNoris Medical provides the medical market with a wide range of solutions.
The company is directed by experienced physicians and professional engineers focusing on development, design and production of innovative products for the medical field. Within this framework, Noris Medical is focused on original products and systems for dental applications.
The synergetic activity of Noris Medical team results in advanced products and outstanding systems that help dentists and patients alike.
Each new product and system developed is supplied with comprehensive peripheral tooling needed for its successful implementation.
Noris Medical offers responsive customer support and ongoing professional training courses to the global community of dental surgeons and technicians.
With decades of collective professional experience, Noris Medical strives to provide the dental implantation market with the highest quality products and systems based on sound engineering principles and excellent manufacturing practices.
/ 3 /
Noris Medical improves the lives of dentists and patients around the world with the leading technology in dental implant systems.
Table of Contents
/ 4 / Implants
Noris Medical invests significant resources in creating an environment for the design and manufacture of its dental products. Keeping patient safety at the forefront throughout the process, Noris Medical complies with international standards for manufacturing and quality. The entire manufacturing process is monitored and recorded for total process traceability. All facilities are subjected to strict inspection procedures.
• Products carry the CE mark and meet the European Medical Device Directive (93/42/EEC).• Products received the FDA Clearance Premarket Notification (510k) (K140440).• Meticulous quality control system is in compliance with ISO 9001:2008, EN ISO 13485:2012 and FDA QSR 21 CFR
Part 820.• Facilities are subject to routine audits by international auditors.• Class 10,000 Clean Room for production.
Titanium alloys are known for their superior biocompatibility and tensile strength. Therefore, all Noris Medical Dental Implants and Prosthetic Components are produced from Titanium Alloy Ti6Al4V (Grade 5).
Macroscopic and microscopic properties of Dental Implant surfaces play a major role in their osseous healing process. Roughened implant surfaces provide increased retention strength. The topography, down to the micrometer, affects the attachment and growth of bone cells.
Noris Medical applies RBM (Resorbable Blast Media) technique in order to induce the sub-micro topography. The material used for RBM process is Calcium Phosphate, which is a highly resorbable and biocompatible material. Usage of Calcium Phosphate as the blasting material also eliminates the need of using strong acids for the removal of blasting material remnants.
Implant surfaces that have been RBM treated are considered to be more osteoconductive. Research showed higher percentage of bone to implant contact around RBM treated implants. This finding could be especially useful in severe clinical conditions like poor bone quality and in cases of early or immediate loading.
ReferencesMcCrcken M. Dental implant material: Commercially pure titanium and titanium alloys. J Prosthod 1999; 8:40-43.
Schwartz Z, Raz P, Zhao G, Barak Y, Tauber M, Yao H, Boyan BD. Effect of micrometer-scale roughness of the surface of Ti6Al4V pedicle screws in vitro and in vivo. J Bone Joint Surg Am. 2008; 90:2485-98.
Piattelli A, Manzon L, Scarano A, Paolantonio M, Piattelli M. Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: An experimental study in rabbits. Int J Oral Maxillofac Implants. 1998;13:805–810.
Piattelli M, Scarano A, Quaranto M, Petrone G, Piattelli A. bone response in rabbit to machined and RBM titanium implants. J Dent Res. 1999;78:1126.
Piattelli M, Scarano A, Paolantonio M, Iezzi G, Petrone G, Piattelli A. Bone response to machined and resorbable blast material titanium implants: an experimental study in rabbits. J Oral Implantol. 2002;28;2-8.
Standards
Materials & Surface Treatment
/ 5 /
Implants
Table of Contents
/ 6 / Implants
Pages 8-9 Pages 10-11 Pages 12-13 Pages 14-15 Pages 16-17 Pages 18 Pages 19 Pages 20-25
Tuff Tuff Pro Tuff TT Onyx Cortical PteryCore PteryFit Zygomatic
Internal Hex. Implants Index
Internal Hex. Drivers
NM-X2620 NM-X2615 NM-X2610 NM-X2607 NM-X1015 NM-X1014
Driver 2.42mm
Motor Mount 2.42mm
RBM Treated surface Machined surface
Implant's Neck Surface Treatment
In accordance with clinical needs or treatment preferences, Tuff, Tuff TT and Onyx implants are available in two neck texture versions: Machined surface or RBM treated surface.
/ 7 /
Pages 26-27 Pages 26-27 Pages 28-29
MBI MBI NC Mono
One Piece Implants Index
Implant Sterile Blister
Implant Holder
Implant
Cover Screw
Tube Casing
InformationSticker
MBI Drivers Mono Drivers
NM-X2415 NM-X1520 NM-X1018 NM-X1019 NM-X1620
Driver 1.7mm
Motor Mount 1.7mm
Driver 2.15mm
Driver 2.15mm
Motor Mount 2.15mm
Table of Contents
/ 8 / Implants
Drilling Speed (RPM) 1200- 1500
900- 1200
1200- 1500
1200- 1500
1200- 1500
1200- 1500
1200- 1500
Drill Diameter md ø2.0 ø2.8 ø3.2 ø3.65 ø4.2 ø4.2
Drill Sequence* Bone type D3, D4
6
10
16
ø3.3 ø3.75 ø4.2 ø5.0 ø6.0
Tuff
With their three thread zones, Tuff implants have been uniquely designed according to the anatomy of the bone structure. The lower V-shape thread zone enables self-tapping. The middle zone square type thread is used for compressing cancellous bone and helping achieve maximum BIC. The micro thread on the upper zone adds stability and prevents crestal bone loss.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
Available in two neck textures (See page 6 for more information)
2.42
L
D1
D
3.75
* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.
* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Farther insertion of the implant will be done with appropriate tool.
* Implant hexagon During implant insertion, the hexagon of the implant, should be located with a straight part of the hexagon toward the angulation needed, in order to provide adequate rehabilitation.
Drilling Speed (RPM) 1200- 1500
900- 1200
500- 700
500- 700
400-700
400-700
400-600
400-600
400-600
400-600
300-500
300-500
200-500
Drill Diameter md ø2.0 ø2.8 ø2.8 ø3.2 ø3.2 ø3.65 ø3.65 ø4.2 ø4.2 ø5.2 ø5.2 ø5-6
Drill Sequence* Bone type D1, D2
6
10
16
ø3.3 ø3.3 ø3.3 ø3.75 ø3.75 ø4.2 ø4.2 ø5.0 ø5.0 ø6.0 ø6.0
? Torque Too high Further Drilling Sequence Insert Implant
? ? ?? ? ?
/ 9 /
Implants Ø D (mm) Ø D1 (mm) L (mm) RBM Treated Neck Machined Neck
3.3 2.6
8 NM-F3308 NMSF3308
10 NM-F3310 NMSF3310
11.5 NM-F3311 NMSF3311
13 NM-F3313 NMSF3313
16 NM-F3316 NMSF3316
3.75 3.1
6 NM-F3706 NMSF3706
8 NM-F3708 NMSF3708
10 NM-F3710 NMSF3710
11.5 NM-F3711 NMSF3711
13 NM-F3713 NMSF3713
16 NM-F3716 NMSF3716
4.2 3.5
6 NM-F4206 NMSF4206
8 NM-F4208 NMSF4208
10 NM-F4210 NMSF4210
11.5 NM-F4211 NMSF4211
13 NM-F4213 NMSF4213
16 NM-F4216 NMSF4216
5.0 4.5
6 NM-F5006 NMSF5006
8 NM-F5008 NMSF5008
10 NM-F5010 NMSF5010
11.5 NM-F5011 NMSF5011
13 NM-F5013 NMSF5013
16 NM-F5016 NMSF5016
6.0 5.2
6 NM-F6006 NMSF6006
8 NM-F6008 NMSF6008
10 NM-F6010 NMSF6010
11.5 NM-F6011 NMSF6011
13 NM-F6013 NMSF6013
16 NM-F6016 NMSF6016
Cover Screw Included with all implants
NM-S5023
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 10 / Implants
Tuff Pro
Tuff Pro implants have been uniquely designed to match the anatomy of the bone structure. The lower V-shape thread zone enables self-tapping. The middle zone square type thread is used for compressing cancellous bone and helping achieve maximum BIC.
The smooth “Neck” surface at the top helps in eliminating the adherence of Perio-Pathogens, thus reducing the chances of an inflammatory process to develop around the neck area. The RBM treated surface increases the BIC.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
L
D1
2.42
3.75
2
D
* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.
* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Farther insertion of the implant will be done with appropriate tool.
* Implant hexagon During implant insertion, the hexagon of the implant, should be located with a straight part of the hexagon toward the angulation needed, in order to provide adequate rehabilitation.
Drilling Speed (RPM) 1200- 1500
900- 1200
1200- 1500
1200- 1500
1200- 1500
1200- 1500
Drill Diameter md ø2.0 ø2.8 ø3.2 ø3.65 ø4.2
Drill Sequence* Bone type D3, D4
6
10
16
ø3.3 ø3.75 ø4.2 ø5.0
Drilling Speed (RPM) 1200- 1500
900- 1200
500- 700
500- 700
400-700
400-700
400-600
400-600
400-600
400-600
300-500
300-500
Drill Diameter md ø2.0 ø2.8 ø2.8 ø3.2 ø3.2 ø3.65 ø3.65 ø4.2 ø4.2 ø5.2 ø5.2
Drill Sequence* Bone type D1, D2
6
10
16
ø3.3 ø3.3 ø3.3 ø3.75 ø3.75 ø4.2 ø4.2 ø5.0 ø5.0
? ? ?? ?
? Torque Too high Further Drilling Sequence Insert Implant
/ 11 /
Implants Ø D (mm) Ø D1 (mm) L (mm) Item
3.3 2.6
10 NMAF3310
11.5 NMAF3311
13 NMAF3313
16 NMAF3316
3.75 3.1
10 NMAF3710
11.5 NMAF3711
13 NMAF3713
16 NMAF3716
4.2 3.5
10 NMAF4210
11.5 NMAF4211
13 NMAF4213
16 NMAF4216
5.0 4.5
10 NMAF5010
11.5 NMAF5011
13 NMAF5013
16 NMAF5016
Cover Screw Included with all implants
NM-S5023
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 12 / Implants
Tuff TT
Tuff TT Implants share the same three-thread zone concept as Tuff implants. The taper top converging coronal shape allows platform switch technology to prevent crestal bone loss.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
Available in two neck textures (See page 6 for more information)
L
D1
D
3.75
2.42
Drilling Speed (RPM) 1200- 1500
900- 1200
500- 700 400-700
400-600
400-600
400-600
300-500
300-500
200-500
Drill Diameter md ø2.0 ø2.8 ø3.2 ø3.65 ø4.2 ø5-6 ø5.2 ø5-6 ø5-6
Drill Sequence* Bone type D1, D2
6
10
16
ø4.2 ø4.2 ø5.0 ø6.0 ø6.0
Drilling Speed (RPM) 1200- 1500
900- 1200
500- 700 400-700
400-600
400-600
300-500
Drill Diameter md ø2.0 ø2.8 ø3.2 ø3.65 ø4.2 ø5.2
Drill Sequence* Bone type D3, D4
6
10
16
ø4.2 ø5.0 ø6.0
* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.
* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Farther insertion of the implant will be done with appropriate tool.
* Implant hexagon During implant insertion, the hexagon of the implant, should be located with a straight part of the hexagon toward the angulation needed, in order to provide adequate rehabilitation.
? ? ?
? Torque Too high Further Drilling Sequence Insert Implant
/ 13 /
Implants Ø D (mm) Ø D1 (mm) L (mm) RBM Treated Neck Machined Neck
4.2 3.5
6 NM-F4306 NMSF4306
8 NM-F4308 NMSF4308
10 NM-F4310 NMSF4310
11.5 NM-F4311 NMSF4311
13 NM-F4313 NMSF4313
16 NM-F4316 NMSF4316
5.0 4.2
6 NM-F5106 NMSF5106
8 NM-F5108 NMSF5108
10 NM-F5110 NMSF5110
11.5 NM-F5111 NMSF5111
13 NM-F5113 NMSF5113
16 NM-F5116 NMSF5116
6.0 5.0
6 NM-F6106 NMSF6106
8 NM-F6108 NMSF6108
10 NM-F6110 NMSF6110
11.5 NM-F6111 NMSF6111
13 NM-F6113 NMSF6113
Cover Screw Included with all implants
NM-S5023
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 14 / Implants
Onyx
Onyx implants are specially designed for treatments involving placement in type I and type II bone.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
Available in two neck textures (See page 6 for more information)
2.42
L
D1
D
3.75
Drilling Speed (RPM) 1200- 1500
900- 1200
500- 700 400-700
200-500
400-600
200-500
400-600
200-500
300-500
200-500
Drill Diameter md ø2.0 ø2.8 ø3.2 ø3.75 ø3.65 ø3.75 ø4.2 ø5-6 ø5.2 ø5-6
Drill Sequence* Bone type D1, D2
6
10
16
ø3.3 ø3.75 ø4.2 ø5.0 ø6.0
Drilling Speed (RPM) 1200- 1500
900- 1200
500- 700 400-700
400-600
400-600
300-500
Drill Diameter md ø2.0 ø2.8 ø3.2 ø3.65 ø5.2 ø4.2
Drill Sequence* Bone type D3, D4
6
10
16
ø3.3 ø3.75 ø4.2 ø5.0 ø6.0
* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.
* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Farther insertion of the implant will be done with appropriate tool.
* Implant hexagon During implant insertion, the hexagon of the implant, should be located with a straight part of the hexagon toward the angulation needed, in order to provide adequate rehabilitation.
/ 15 /
Implants Ø D (mm) Ø D1 (mm) L (mm) RBM Treated Neck Machined Neck
3.3 2.4
8 NM-G3308 NMSG3308
10 NM-G3310 NMSG3310
11.5 NM-G3311 NMSG3311
13 NM-G3313 NMSG3313
16 NM-G3316 NMSG3316
3.75 2.8
6 NM-G3706 NMSG3706
8 NM-G3708 NMSG3708
10 NM-G3710 NMSG3710
11.5 NM-G3711 NMSG3711
13 NM-G3713 NMSG3713
16 NM-G3716 NMSG3716
4.2 3.2
6 NM-G4206 NMSG4206
8 NM-G4208 NMSG4208
10 NM-G4210 NMSG4210
11.5 NM-G4211 NMSG4211
13 NM-G4213 NMSG4213
16 NM-G4216 NMSG4216
5.0 4.0
6 NM-G5006 NMSG5006
8 NM-G5008 NMSG5008
10 NM-G5010 NMSG5010
11.5 NM-G5011 NMSG5011
13 NM-G5013 NMSG5013
16 NM-G5016 NMSG5016
6.0 5.0
6 NM-G6006 NMSG6006
8 NM-G6008 NMSG6008
10 NM-G6010 NMSG6010
11.5 NM-G6011 NMSG6011
13 NM-G6013 NMSG6013
Cover Screw Included with all implants
NM-S5023
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 16 / Implants
Drilling Speed (RPM) 1200- 1500
900- 1200
500- 700
200-500 400-700
200-500
Drill Diameter md ø2.0 ø2.8 ø3.2 ø3.2 ø3.65
Drill Sequence* Bone type D1, D2
6
10
16
ø4.0 ø4.0 ø5.0 ø5.0 ø6.0
Drilling Speed (RPM) 1200- 1500
900- 1200
500- 700
Drill Diameter md ø2.0 ø2.8
Drill Sequence* Bone type D1, D2
6
10
16
ø4.0 ø5.0 ø6.0
Cortical
Cortical implants provide good stability for immediate loading. Its sharp, deep threads provide extremely strong retention for primary implant stability. The threads’ location gives stability in the cortical bone. The Cortical system can be used in extraction sites for immediate implantation. Cortical is available in different sizes to suit any implantation site.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
L
L2
D
4
3.75
4
L1
1.6
2.42
* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.
* Implant Carrier removal After the osteotomy preparation, the implant should be inserted with the aid of the implant carrier. The implant should be initially stabilized by a few threads and then the carrier should be removed. Farther insertion of the implant will be done with appropriate tool.
* Implant hexagon During implant insertion, the hexagon of the implant, should be located with a straight part of the hexagon toward the angulation needed, in order to provide adequate rehabilitation.
? ?
? Torque Too high Further Drilling Sequence Insert Implant
/ 17 /
Implants Ø D (mm) L (mm) L1 (mm) L2 (mm) Item
4.0
10 4.5 5.5 NM-M4010
11.5 4.7 6.8 NM-M4011
13 5 8 NM-M4013
16 6 10 NM-M4016
5.0
8 4.1 3.9 NM-M5008
10 4.5 5.5 NM-M5010
11.5 4.7 6.8 NM-M5011
13 5 8 NM-M5013
16 6 10 NM-M5016
6.0
8 4.1 3.9 NM-M6008
10 4.5 5.5 NM-M6010
11.5 4.7 6.8 NM-M6011
13 5 8 NM-M6013
Cover Screw Included with all implants
NM-S5023
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 18 / Implants
PteryCore
Implants Ø D (mm) L (mm) L1 (mm) L2 (mm) Item
4.2
18 7 11 NM-M4218
20 7 13 NM-M4220
22.5 7 15.5 NM-M4222
25 7 18 NM-M4225
Cover Screw Included with all implants
NM-S5023
4.2
2.42
3.75
L2
4.2
L
L1
4
1.7
PteryCore implants are installed in the posterior Maxilla and located in the Pterygomaxillary region. Their Sharp, deep threads provide extremely strong retention for primary implant stability. As such they provide good stability for Immediate Loading procedures.
PteryCore Implants are designed to have a smooth surface at their “Neck”, followed by RBM treated surface underneath.
The smooth “Neck” surface at the top helps in eliminating the adherence of Perio-Pathogens, thus reducing the chances of an inflammatory process to develop around the neck area. The RBM treated surface increases the BIC.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
/ 19 /
PteryFit
Implants Ø D (mm) Ø D1 (mm) L (mm) Item
4.2 3.5
18 NMAF4218
20 NMAF4220
22 NMAF4222
25 NMAF4225
Cover Screw Included with all implants
NM-S5023
L
D1
5
2.42
3.75
D
PteryFit implants are installed in the posterior Maxilla and are located in the Pterygomaxillary region.
PteryFit implants have been uniquely designed to match the anatomy of the bone structure. The lower V-shaped thread zone enables self-tapping. The middle zone square type thread is used for compressing cancellous bone and help achieving maximum BIC.
The smooth “Neck” surface at the top helps in eliminating the adherence of Perio-Pathogens, thus reducing the chances of an inflammatory process to develop around the neck area. The RBM treated surface increases the BIC.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 20 / Implants
Pterygoid Implants for Posterior Maxilla Rehabilitation
/ 21 /
Pterygoid Implants Tools
OsteotomesØ D (mm) Item
2.0 NM-X3001
3.0 NM-X3002
Long DrillsØ D (mm) Item
2.3 NM-D7423
2.8 NM-D7428
3.2 NM-D7432
3.65 NM-D7436
2522201816
Depth Groove (mm)
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
16 18 20 22 25La
ser M
ark
Col
or C
ode
25222018151311.5
Depth Groove (mm)
3.2
Table of Contents
/ 22 / Implants
Implants Ø D (mm) Ø D1 (mm) L (mm) Item
4.2 3.5
30 NM-F4430
32.5 NM-F4432
35 NM-F4435
37.5 NM-F4437
40 NM-F4440
42.5 NM-F4442
45 NM-F4445
47.5 NM-F4447
50 NM-F4450
52.5 NM-F4452
55 NM-F4455
57.5 NM-F4457
60 NM-F4460
Cover Screw Included with all implants
NM-S5023
Zygomatic
The Zygomatic Implant is designed to provide a solution for cases of atrophic maxilla. The shape of the Zygomatic Implant consists of sharp threads at the apical part for maximum retention to the Zygomatic bone. The implant has 2.43mm internal hex. connection, which enable simple and easy restoration. The Zygomatic Implant is available in a variety of lengths, from 35mm to 57.5mm.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
2.42
3.75
D
D1
12.5
L
/ 23 /
Drill Sequence
60
55
50
45
40
35
30
60
55
50
45
40
35
1
60
55
50
45
40
35
2
60
55
50
45
40
35
3
16
ø2.8ø2.8ø2.8ø2
ø3.2ø3.2ø3ø3
ø2.5
ø4.2ø4.2ø4.2ø4.2
D4 D3 D2 D1Bone Type
8
4
0
60
55
50
45
40
35
3
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 24 / Implants
Zygomatic
Zygomatic Surgical Kit NM-X2118
/ 25 /
Depth Probe NM-X1028
0 D (mm) L (mm) Item
4.2 30
Fine Grit NM-D7201
Medium Grit NM-D7202
Coarse Grit NM-D7203
Zygomatic Burs for Groove Preparation
Zygomatic Step Drills
0 D (mm) L (mm) Drill No. Item
2.0
40
1
NM-D7520
60 NM-D7020
80 NM-D7120
2.8
40
2
NM-D7528
60 NM-D7028
80 NM-D7128
3.2
40
3
NM-D7532
60 NM-D7032
80 NM-D7132
L
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 26 / Implants
MBI / MBI NC
MBI & MBI NC are One-Piece, self-tapping Implants, with integrated ball attachment, for single-stage implantation to stabilize a tissue-supported denture. Designed for placement in a very narrow ridge. MBI & MBI NC features a unique thread for immediate insertion. The implants can be placed in all types of bone and can be subjected to immediate load.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
Drilling Speed (RPM) 1200- 1500
1200- 1500 900-1200
Drill Diameter ø1.2 ø1.5 ø2.0
Drill Sequence* Bone type D1, D2
6
10
16
ø2.0 ø2.4 ø2.9
Drilling Speed (RPM) 1200- 1500
1200- 1500
1200- 1500
1200- 1500
Drill Diameter ø1.2 ø1.2 ø1.5 ø1.5
Drill Sequence* Bone type D3, D4
6
10
16
ø2.0 ø2.4 ø2.9
* The proposed procedure is only a recommendation and should not replace the doctor's judgment. MBI Torque Recommendations: Do not exceed 45 Ncm during implant placement. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.
1.8
4
H
L
D
L1
1.7
L
1.8
D1
1.7
4.2
D
/ 27 /
NM-D2312 NM-D2315 NM-X1520 NM-X2415 NM-T6124 NM-T4410
Drill Ø 1.2mm
Drill Ø 1.5mm
Motor Mount 1.7mm
Driver 1.7mm
Analog Transfer
ø 4.3
2.8
ø 3.4
2.3
NM-T3201 NM-T3202 NM-T3203
Metal Cap Extra Soft Nylon Cap Soft Nylon Cap
MBI & MBI NC Components
Implants Ø D (mm) Ø D1 (mm) neck (H) (mm) L (mm) Item
2.0 1.0 0
10 NMTV2010
13 NMTV2013
16 NMTV2016
18 NMTV2018
2.4 1.5 0
10 NMTV2410
13 NMTV2413
16 NMTV2416
18 NMTV2418
2.9 1.9 0
10 NMTV2910
13 NMTV2913
16 NMTV2916
18 NMTV2918
MBI NC (Non Collar)
Implants Ø D (mm) Ø D1 (mm) neck (H) (mm) L (mm) Item
2.0 1.0 2.5
10 NM-V2010
13 NM-V2013
16 NM-V2016
18 NM-V2018
2.4 1.5 2.5
10 NM-V2410
13 NM-V2413
16 NM-V2416
18 NM-V2418
2.9 1.9 2.5
10 NM-V2910
13 NM-V2913
16 NM-V2916
18 NM-V2918
MBI
NM-D2312 NM-D2315 NM-X1520 NM-X2415 NM-T6124 NM-T4410
Drill Ø 1.2mm
Drill Ø 1.5mm
Motor Mount 1.7mm
Driver 1.7mm
Analog Transfer
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 28 / Implants
D1 D
L
6.5
3
2.15
Mono
Mono implants are specifically indicated for replacing maxillary lateral incisors and mandibular central and lateral incisors. The implants are cleared for immediate, non-occlusal provisionalization in single-tooth restorations. Multiple-unit restorations should be splinted together. In appropriate clinical conditions MONO Implants may be loaded immediately.
Material: Titanium (Ti6Al4V ELI) Treatment: RBM
Drilling Speed (RPM) 1200- 1500
1200- 1500
200-500
900-1200
500-700
500-700
Drill Diameter md ø1.5 ø2.0 ø2.0 ø2.8 ø3.2
Drill Sequence* Bone type D3, D4
6
10
16
ø3.0 ø3.3 ø3.75 ø4.2 ø5.0
* The proposed procedure is only a recommendation and should not replace the doctor's judgment. The implants may be placed in immediate function when good primary stability (above 35 Ncm) has been achieved and with appropriate occlusal loading.
Drilling Speed (RPM) 1200- 1500
1200- 1500
200-500
900-1200
200-500
500-700
200-500 400-700
200-500
Drill Diameter md ø1.5 ø2.0 ø2.0 ø2.8 ø2.8 ø3.2 ø3.2 ø3.65
Drill Sequence* Bone type D1, D2
6
10
16
ø3.0 ø3.3 ø3.75 ø4.2 ø5.0
/ 29 /
Implants Ø D (mm) ø D1 (mm) L (mm) Item
3.0 1.7
10 NM-V3010
11.5 NM-V3011
13 NM-V3013
16 NM-V3016
3.3 2.0
10 NM-V3310
11.5 NM-V3311
13 NM-V3313
16 NM-V3316
3.75 2.4
10 NM-V3710
11.5 NM-V3711
13 NM-V3713
16 NM-V3716
4.2 2.9
10 NM-V4210
11.5 NM-V4211
13 NM-V4213
16 NM-V4216
18 NM-V4218
5.0 3.7
10 NM-V5010
11.5 NM-V5011
13 NM-V5013
6
10
NM-D2315 NM-X1620 NM-X1018 NM-X1019 NM-T6202 NM-T4420
Drill Ø 1.5mm
Motor Mount 2.15mm
Driver 2.15mm
Driver 2.15mm
Analog Transfer
Mono Components
Mon
oM
BI &
MB
I NC
Zygo
mat
icPt
eryF
itPt
eryC
ore
Cor
tical
Ony
xTu
ff TT
Tuff
Pro
Tuff
Table of Contents
/ 30 / Implants
Use by date
Sterile package unless opened or damaged
Sterilized using irradiation
Do not re-use
Do not resterilize
Consult accompanying documents
Caution: Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner
CEpartner4U Esdoornlaan 13, 3951 db Maarn, The Netherlands www.cepartner4u.eu
Packaging
Implant Label
Prosthetic Label
/ 31 /
Prosthetics
Table of Contents
/ 32 / Prosthetics
NM-X1207 NM-X1210 NM-X1215 NM-X1006 NM-X1007 NM-X1011 NM-X1008 NM-X1009 NM-X1010
Driver 1.25mm
Hand Driver 1.25mm
Motor Mount 1.25mm
Prosthetic Components Drivers
Prosthetic Workflow
Healing Cap Impression Components
Pages 34 Page 35-37
Closed Tray TransferOpen Tray Transfer
Snap-On Transfer Clip-On Tray Transfer
Analog
or
or
/ 33 /
Scan Abutments
Titanium Base
NM-X1016 NM-X1017 NM-X7006 NM-X7007 NM-X7011 NM-X7008 NM-X7009 NM-X7010
Driver 2.0mm
Hand Driver 1.25mm
Motor Mount 1.25mm
Multi-Unit & Vari-Connect Drivers
Angulated Abutment
Straight Abutment
Temporary Abutment
or
or
or
Zirconia Abutment
Castable Abutment
or
Cement Retained Restorations CAD/CAM Removable
Restorations
Page 38-45 Page 46-47 Page 58-62
Flat Vari-Connect
Ball Attachent
Ball Vari-Connect
or
Flat Attachent
Noris lock
or
or
or
Screw Retained Restorations
Page 50-56
Straight Multi-Unit
Angulated Multi-Unit
or
or
Esthetic Screw Abutment
Table of Contents
/ 34 / Prosthetics
L (mm) Ø 3.8 (mm) Ø 4.6 (mm) Ø 5.5 (mm) Ø 6.3 (mm)
2
NM-H3802 NM-H4602 NM-H5502 -
3
NM-H3803 NM-H4603 NM-H5503 NM-H6303
4
NM-H3804 NM-H4604 NM-H5504 NM-H6304
5
NM-H3805 NM-H4605 NM-H5505 NM-H6305
6
NM-H3806 NM-H4606 NM-H5506 NM-H6306
7
NM-H3807 NM-H4607 NM-H5507 NM-H6307
Healing Caps
Healing caps prepare the site for the superstructure insertion and “shapes” the soft tissue surrounding the implant. Selecting the correct healing cap depends on the thickness of the mucosa. Wide healing caps are used for soft-tissue contouring of molars and premolars.
Recommendation: Hand-tighten using a 1.25 mm hex. driver or a motor mount with a force of 10 Ncm.
Material: Titanium (Ti6Al4V ELI)
D3.750
L
1.28
/ 35 /
Transfers are designed for impressions using the open-tray technique when the retentions are sharp, and for the closed-tray technique when the retentions are round. The body of the transfer is made of stainless steel; the screws are made of titanium alloy.
Material: Stainless Steel
Open Tray TransferTransfer Ø D (mm) L (mm)
4.75 8NM-T4008
Screw 16mm Included with all transfers above & available separatelyNM-S1610
3.85 12NM-T4203
4.3 12NM-T4201
4.75 12NM-T4012
Screw 24mm Included with all transfers above & available separately
NM-S2418
Non-Hexed TransferTransfer Ø D (mm) L (mm)
3.85 12NM-T4204
Screw 24mm Included with all transfers above & available separately
NM-S2418
Open & Closed Tray Transfers
Closed Tray TransferTransfer Ø D (mm) L (mm)
4.75 8NM-T3601
Screw 13mm Included with all transfers above & available separatelyNM-S1307
3.85 12NM-T3507
4.5 12NM-T3511
Screw 16mm Included with all transfers above & available separatelyNM-S1610
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
3.75
L
D
2.42
Table of Contents
/ 36 / Prosthetics
Snap-On Transfer
The Snap-On Transfer is made of titanium alloy TI-6AL-4V and designed for impressions using the closed-tray technique, in conjunction with the cap T4402. The cap remains in the impression tray after it is removed from the mouth. It is also possible to use this type of transfer as esthetic abutments.
Material: Titanium (Ti6Al4V ELI)
Transfer Ø D (mm) L1 (mm)
4.8 2
NM-T3802
4.8 3
NM-T3803
4.8 4
NM-T3804
4.8 5
NM-T3805
4.8 6
NM-T3806
Included with all abutments above & available separately
NM-S8324
Plastic Cap for Snap-On Transfer
Cap Ø D (mm) L (mm)
4.8 11
NM-T4402
D
L
8
3.75
L
2.42
D
/ 37 /
A clip-on connection transfer for impressions without a screw has a hexagonal lock to ensure a tight fit. It is especially effective with molars and premolars, where there is a lack of space, and where working with a driver is difficult. It is sufficient to use this transfer for all types of impressions as the lack of screws saves significant amount of time.
Material: Stainless Steel
Transfer Ø D (mm) L (mm)
4.7 9
NM-T3409
4.7 13
NM-T3413
L
D3.75
2.42
Clip-On Transfer
The analog is made of stainless steel and is used in the preparation of laboratory models.
Material: Stainless Steel
Analog Ø D (mm) L (mm)
4 12.7
NM-T6004
5 12.7
NM-T6005
D
3.75
L
2.43
Analog A
cces
sorie
sC
emen
t Ret
aine
d Re
stor
atio
nsSc
rew
Ret
aine
dRe
stor
atio
nsRe
mov
able
Rest
orat
ions
Table of Contents
/ 38 / Prosthetics
Temporary Abutments
PEEK (polyetheretherketone) is a high-grade thermoplastic polymer which is certified for medical use. PEEK is characterized by a superior combination of strength, elasticity and resilience. PEEK is one of the most chemically resistant materials, Biocompatible and esthetic with low electrical conductivity. PEEK polymer is well suited for use in the oral cavity.
Material: PEEK
Straight L (mm) Angulated 15° Angulated 25° L (mm) L1 (mm)
9 9.5 1
NM-C6001 NM-C5001 NM-C5201
10 10.5 2
NM-C6002 NM-C5002 NM-C5202
11 11.5 3
NM-C6003 NM-C5003 NM-C5203
3.750
L
L1
2.42
D
2
Technical Data:
• Can be sterilized without changing the mechanical properties or biocompatibility violations.
• Does not create artifacts in X-ray irradiation procedures, magnetic resonance imaging (MRI), and computed tomography (CT).
• Has high compressive strength.
• Possesses excellent mechanical properties such as stiffness and strength.
• Has proven biocompatibility for both hard and soft tissue.
• Does not contain metal additives to prevent ion exchange in the mouth.
• Is a natural color, a superior esthetic advantage.
/ 39 /
Temporary Abutments
The titanium Temporary Abutments are designed with deep retention grooves, for the acrylic prosthesis to hold to. The abutments are available hexed and non-hexed.
Material: Titanium (Ti6Al4V ELI)
Hexed Non-Hexed Short Non-Hexed L (mm) L1 (mm) Ø D (mm)
9.5 1.7 4.4
NM-A5001 NM-A5002 -
9.5 1.7 3.8
NM-A5101 - NM-A5102
Included with all abutments above & available separately
NM-S8324
L
2.42
D
3.75
L1
3.2 Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Table of Contents
/ 40 / Prosthetics
Straight Abutments
A wide variety of titanium straight abutments are available for use in different situations. These abutments remain stable, even when their wall thickness is reduced to 0.1 mm. They are used in the fabrication of cement-retained restorations, single crowns or bridges.
Recommendation: Tighten the screw at a torque between 25 to 30 Ncm.
Material: Titanium (Ti6Al4V ELI)
Anatomic Ø D (mm) L (mm) L1 (mm)
5.2 9 1
NM-A4601
5.2 10 2
NM-A4602
5.2 11 3
NM-A4603
5.2 12 4
NM-A4604
Included with all abutments & available separately
NM-S8324
Shoulder Ø D (mm) L (mm) L1 (mm)
4.5 8.5 1
NM-A4801
4.5 9.5 2
NM-A4802
4.5 10.5 3
NM-A4803
4.5 11.5 4
NM-A4804
Available separately
NM-C1005
3.750
L
L1
2.42
D
2
/ 41 /
Mega Ø D (mm) L (mm)
9 15
NM-A5515
Standard Ø D (mm) L (mm)
4.5 8.5
NM-A5908
4.5 9.5
NM-A5909
4.5 11.5
NM-A5911
4.5 12.5
NM-A5912
Wide Ø D (mm) L (mm)
5.5 9NM-A5709
5.5 11NM-A5711
Shoulder, Narrow Ø D (mm) L (mm) L1 (mm)
3.75 8.5 0.5NM-A5300
3.75 8.5 1.5NM-A5301
3.75 8.5 2.5NM-A5302
Narrow Ø D (mm) L (mm)
3.8 6NM-A6006
3.8 8NM-A6008
Standard Ø D (mm) L (mm)
4.5 8.5
NM-A5601
4.5 10.5
NM-A5602
Mega, Co-Cr Ø D (mm) L (mm)
15 15
NM-A5516
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Table of Contents
/ 42 / Prosthetics
AnatomicAngulated 15° Angulated 25° Ø D (mm) L (mm) L1 (mm)
5.4 9.5 1
NM-A2401 NM-A2601
5.4 10.5 2
NM-A2402 NM-A2602
5.4 11.5 3
NM-A2403 NM-A2603
5.4 12.5 4
NM-A2404 NM-A2604
Angulated Abutments
Angulated abutments are used when a change to the axis of the implant is required. Normally used for constructing cement-retained single crowns or bridges. The abutments are available with angles of 15° and 25° degrees.
Recommendation: Tighten the screw at a torque between 25 to 30 Ncm.
Material: Titanium (Ti6Al4V ELI)
15°
L1
D 3.75
L
2
2.42
/ 43 /
Narrow TopAngulated 15° Angulated 25° L (mm)
9
NM-A2809 NM-A3009
Narrow Angulated 15° Ø D (mm) L (mm)
4 9
NM-A3609
StandardAngulated 15° Angulated 25° Ø D (mm) L (mm)
4.5 9
NM-A3209 NM-A3409
4.5 11
NM-A3211 NM-A3411
Included with all abutments & available separately
NM-S8324
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Table of Contents
/ 44 / Prosthetics
Titanium Base
for Zirconia
NM-S1001 NM-Z1001
AnatomicStraight L (mm) L1 (mm) Angulated 15° Angulated 25° L (mm) L1 (mm)
8.5 0.5 9 0.5
NM-Z5600 NM-Z3400 NM-Z3600
9 1 9.5 1
NM-Z5601 NM-Z3401 NM-Z3601
10 2 10.5 2
NM-Z5602 NM-Z3402 NM-Z3602
11 3 11.5 3
NM-Z5603 NM-Z3403 NM-Z3603
Titanium Base Zirconia Abutments
Zirconia is an esthetic alternative material for the traditional titanium abutments. The abutments are available as fully cast zirconia or with a titanium base in a wide variety of shapes and sizes.
Material: Zirconium
15°
L1
D 3.75
L
2
2.42
/ 45 /
15°
L1
D 3.75
L
2
2.42
Castable Abutments
Plastic Castable Abutments are intended for use by the technician for simple casting of custom-made abutments for constructing the prosthetic restoration.
Plastic Castable Abutments on Titanium Bases enable the dental laboratory to cast on an accurate Titanium base. The machined Titanium base provides an accurate fit to the implant.
Material: Delrin
Straight L (mm) Angulated 15° Angulated 25° L (mm) L1 (mm)
9 9.5 1
NM-C4001 NM-C3001 NM-C3201
10 10.5 2
NM-C4002 NM-C3002 NM-C3202
11 11.5 3
NM-C4003 NM-C3003 NM-C3203
Hexed Non-Hexed L (mm) Ø D (mm) Angulated 15° L (mm) Ø D (mm)
8.5 4.5 8.5 4.5NM-C2004 NM-C2003 NM-C2005
10.5 3.25
NM-C1002 NM-C1001
Titanium Base Co-Cr Base L (mm) Ø D (mm)
10.5 4.5
NM-C2001 NM-C2002
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Included with all abutments & available separately
NM-S8324
Table of Contents
/ 46 / Prosthetics
Scan Abutments Ø D (mm) L (mm)
4.8 7
D3.75
L
2.42
MN-C9007
4.8 10
MN-C9010
Single Unit Titanium Base Ø D (mm) L (mm)
4.8 4.5
L
3.75 D
2.42
NM-C2201
NM-C2201
Multiple Units Titanium Base Ø D (mm) L (mm)
4.8 4.5
L
3.75 D
2.42
Flat Platform Base for CAD/CAM
NM-C2202
Included with all abutments & available separately
NM-S8324
CAD/CAM Abutments
The CAD/CAM abutment are especially designed for CAD/CAM fabrication of individual abutments.
Recommendation: Tighten the screw NM-S8324 at a torque between 25 to 30 Ncm. Tighten the screw NM-S7102 at a torque of 15 Ncm.
Material: Titanium (Ti6Al4V ELI) & PEEK
/ 47 /
Multi-Unit Scan Abutments Ø D (mm) L (mm)
4.8 7D1
D
L
MN-C9107
4.8 10
MN-C9110
Multi-Unit Titanium Base Ø D (mm) L (mm)
4.8 4.5 L
D
NM-C7124
Included with all abutments
NM-S7102
Individual Blank for Milling Ø D (mm) L (mm)
10 26
D
L
2.42 3.75
D1
NM-A5517
Included with all abutments & available separately
NM-S8324
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Table of Contents
/ 48 / Prosthetics
A NEW SMILEIN ONE DAY
IMMEDIATELOADING
/ 49 /
Multi-Unit
Table of Contents
/ 50 / Prosthetics
3.75
4.8
L1
2.0
3.75
a
L1
2.42
Multi-Unit | Straight & Angulated
The Multi-Unit system provides a solution for screw-retained prostheses even on complicated-to-restore implants (for example, multiple tilted implants). The Multi-Unit system comprises a full range of sizes for both the upper and lower jaws. Straight, 17°, 30°, 45°, 52° and 60° adaptors, in a variety of heights, connects to a wide range of complementary products.
Material: Titanium (Ti6Al4V ELI)
Straight L (mm)
1NM-A7101
2NM-A7102
3NM-A7103
4NM-A7104
5NM-A7105
NM-X7100
Included with all multi-unit bases
Angulated 17 °
Angulated 30°
Angulated 45°
Angulated 52°
Angulated 60° L (mm)
2NM-A7112
3NM-A7113 NM-A7133
4NM-A7134 NM-A7144
5NM-A7152 NM-A7160
Included with all multi-unit bases
NM-S7101 NM-X7101
Recommendation: Tighten the screw at a torque of 20 Ncm.Recommendation: Tighten the base at a torque of 25 Ncm.
/ 51 /
60°45°
30°0°52°
17°
Multi-Unit System
Entire Product Line for Immediate Loading
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Table of Contents
/ 52 / Prosthetics
Multi-Unit Components
Passive Fit Castable Abutment Kit
Screw*
NM-S7102
Universal AbutmentØ 4.8mm H 12mm
NM-T7121
Castable SleeveØ 4.8mm H 10.5mm
NM-C7120
Castable Sleeve PositionerØ 4.8mm H 10mm
NM-T7122
The Passive Fit Castable Abutment Kit consists of three parts aimed for the fabrications of accurate metal reinforced prostheses.
The Castable Sleeve Positioner is used for locating the Castable Sleeve on the plaster model, ensuring passive fit of the fabricated metal cast when cemented to the Titanium Abutments.
* Recommendation: Tighten the screw at a torque of 15 Ncm.
Healing Cap
Screw
NM-S7102
Healing CapØ 4.8mm H 4.3mm
NM-H7101
Transfers & Analog
ScrewL 13mm
NM-S7111
Open TrayØ 4.8mm H 11mm
NM-T7111
Plastic CapØ 4.8mm H 11mm
NM-T4402
Screw
NM-S7102
2 m
m
Closed TrayØ 4.8mm H 8mm
NM-T7102
AnalogØ 4.8mm
NM-T7151
Abutments
Screw*
NM-S7102
Ø 3.3 mm
Universal AbutmentØ 4.8mm H 12mm
NM-T7121
Screw*
NM-S7102
Ø 3.8 mm
Wide Universal AbutmentØ 4.8mm H 12mm
NM-T7123
Screw*
NM-S7102
Castable AbutmentØ 4.8mm H 12mm
NM-C7121
Abutment for CAD/CAM
Screw*
NM-S7102
Ø 4.8mm H 4.5mm
NM-C7124
Scan Abutments
Ø 4.8mm H 7mm
MN-C9107
Ø 4.8mm H 10mm
MN-C9110
* Recommendation: Tighten the screw at a torque of 15 Ncm.
* Recommendation: Tighten the screw at a torque of 15 Ncm.
/ 53 /
Straight Multi-Unit Drivers
Short Driver 2.0mm L 6mm
NM-X1016
Long Driver 2.0mm L 10mm
NM-X1017
Straight Multi-Unit Motor Mounts
Short Motor Mount 2.0mm L 20mm
NM-X1120
Long Motor Mount 2.0mm L 25mm
NM-X1125
Multi-Unit Drivers
Star Hex. Drivers
Short Driver 1.25mm L 7mm
NM-X7006
Long Driver 1.25mm L 14mm
NM-X7007
Long Driver 1.25mm L 20mm
NM-X7011
Star Hex. Motor Mounts
Motor Mount 1.25mm L 20mm
NM-X7008
Motor Mount 1.25mm L 25mm
NM-X7009
Motor Mount 1.25mm L 35mm
NM-X7010
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Table of Contents
/ 54 / Prosthetics
Multi-Unit Protocol
Assembly of a Straight Multi-Unit Base
Assembly of Angled Multi-Unit Base
Impression
Choose the desired impression technique:
Healing Cap Assembly
1
2
1
2
33
4
Adjust the straight Multi-Unit Base to the implant by using the plastic handle.
Adjust the Multi-Unit base to the appropriate angle.
Use the handle as an indicator for the final screw emergence.
For closed tray choose Snap-On-Transfer.
For open tray technique choose conventional Transfer.
Remove the handle.
Tighten the base at 25 Ncm, with a 2.0mm Straight Multi-Unit Driver.
Remove the handle by unscrewing it out.
use the Angulated Guide Pin to choose the right correction angle.
orTighten the base at 20 Ncm, with a 1.25mm Hex Driver or a Star Driver.
/ 55 /
Immediate Loading(Fabrication of the temporary bridge)
Laboratory Phase Passive Fit Castable Abutment Kit
1 1
2
Assemble the Titanium Sleeve on the Multi-Unit base and tighten the screw at 15 Ncm.
Mount the Plastic Sleeve on the Multi-Unit analog and tighten with the screw.
3
Carve the Sleeves to the desired shape.
2
Splint the sleeves.
4
Invest and cast the metal frame of the prosthesis.
Attach the pre-prepared provisional acrylic prosthesis
The Passive Fit Castable Abutment Kit consists of three parts aimed for the fabrication of accurate metal reinforced prostheses. The uniquely designed Castable Sleeve Positioner is used for locating the Castable Sleeve on the plaster model, ensuring passive fit of the fabricated metal cast when cemented to the Titanium Abutments.
Table of Contents
/ 56 / Prosthetics
Esthetic Screw Abutments
Esthetic Screw Abutment is designed for the screw retained rehabilitation process on single or multiple units.
The height of the abutment is selected according to the thickness of the mucosa.
The Esthetic Screw Abutment base is supplied with an appropriate screw adjusted to the height of the abutment together with a plastic sleeve for casting.
Sleeves are available with or without internal hex.
Material: Titanium (Ti6Al4V ELI)
Base L (mm)
0.5
NM-E1005
1.5
NM-E1015
2.5
NM-E1025
Hexed Non-Hexed L (mm)
12
NM-C1015 NM-C1007
Screw L (mm)
10.5
NM-S1002
11.5
NM-S1102
12.5
NM-S1202
4.7
L
2.42 3.75
2.1
/ 57 /
Vari-Connect
Table of Contents
/ 58 / Prosthetics
Included with all vari-connect bases
NM-S7101 NM-X7101
Vari-Connect
The Vari-Connect system presents a complete solution for removable prostheses on tilted implants. It provides all the required equipment for removable prostheses, both on ball attachments and flat attachments, covering a wide range of possible situations. Straight, 17°, 30° and 45° adaptors are available. Complementary products are fixed to the adaptors by the adaptor thread.
Material: Titanium (Ti6Al4V ELI)
Angulated 17 ° Angulated 30° Angulated 45° L (mm)
2
NM-A7212 - -
3
NM-A7213 NM-A7233 -
4
- NM-A7234 NM-A7244
Recommendation: Tighten the screw at a torque of 30 Ncm.
Ax
3.75
L
2.42
/ 59 /
Vari-Connect Components
Healing Cap
Screw
NM-S7102
Healing CapØ 4.8mm H 4.3mm
NM-H7101
Transfers & Analog
ScrewL 13mm
NM-S7111
Open TrayØ 4.8mm H 11mm
NM-T7111
Plastic CapØ 4.8mm H 11mm
NM-T4402
Screw
NM-S7102
2mm
Closed TrayØ 4.8mm H 8mm
NM-T7102
AnalogØ 4.8mm
NM-T7251
Ball-Connect
Ball-ConnectØ 4.8mm, H 2mm
NM-T7262
Ball-ConnectØ 4.8mm, H 3mm
NM-T7263
Ball-ConnectØ 4.8mm, H 4mm
NM-T7264
Metal CapØ 5mm, H 3.2mm
NM-T3001
Nylon Extra Soft Cap
NM-T3002
Nylon Soft Cap
NM-T3003
Nylon Standard Cap
NM-T3004
Star Hex. Drivers
Short Driver 1.25mm L 7mm
NM-X7006
Long Driver 1.25mm L 14mm
NM-X7007
Long Driver 1.25mm L 20mm
NM-X7011
Flat-Connect
Flat-ConnectØ 4.8mm, H 3mm
NM-T7273
Flat-ConnectØ 4.8mm, H 4mm
NM-T7274
Metal CapØ 5.5mm, H 2.3mm
NM-T3010
Nylon Extra Soft Cap
NM-T3015
Nylon Soft Cap
NM-T3016
Nylon Standard Cap
NM-T3017
Laboratory Cap
NM-T3018
Sealing Disc
NM-T1824
Available as Set NM-T3099
Star Hex. Motor Mounts
Motor Mount 1.25mm L 20mm
NM-X7008
Motor Mount 1.25mm L 25mm
NM-X7009
Motor Mount 1.25mm L 35mm
NM-X7010
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Table of Contents
/ 60 / Prosthetics
Ball Attachment
The ball attachment superstructure is intended to secure a removable prosthesis. The attachment is used in conjunction with a stainless steel cap and an intermediate Nylone insert.
Material: Titanium (Ti6Al4V ELI)
Ball Attachment L (mm)
0.5
NM-T1200
1
NM-T1201
2
NM-T1202
3
NM-T1203
Ball Attachment L (mm)
4
NM-T1204
5
NM-T1205
6
NM-T1206
Caps for 2.5mm Ball AttachmentMetal Extr Soft Nylon Soft Nylon Standard Nylon
ø 5
3.2
NM-T3001 NM-T3002 NM-T3003 NM-T3004
L
3.75
1.28 2.5
/ 61 /
The flat attachment superstructure is intended to secure a removable prosthesis. The attachment is used in conjunction with a stainless steel cap and an intermediate Nylone insert.
Material: Titanium (Ti6Al4V ELI)
Flat Attachment L (mm)
0.5
NM-T1100
1
NM-T1101
2
NM-T1102
Flat Attachment L (mm)
3
NM-T1103
4
NM-T1104
5
NM-T1105
Flat Attachment
2
L
3.75
2.1 1.52
Caps for Flat Attachment | Set NM-T3099 Metal Extra Soft Nylon Soft Nylon Standard Nylon Laboratory Sealing Disc
ø 5.5
2.3
NM-T3010 NM-T3015 NM-T3016 NM-T3017 NM-T3018 NM-T1824
Acc
esso
ries
Cem
ent R
etai
ned
Rest
orat
ions
Scre
w R
etai
ned
Rest
orat
ions
Rem
ovab
leRe
stor
atio
ns
Table of Contents
/ 62 / Prosthetics
Noris Lock
The Noris Lock attachment superstructure is intended to secure a removable prosthesis. The attachment is used in conjunction with a stainless steel cap and an intermediate Nylone insert.
Material: Titanium (Ti6Al4V ELI)
Lock Attachment L (mm)
0.5
NM-T1300
1
NM-T1301
2
NM-T1302
3
NM-T1303
Lock Attachment L (mm)
4
NM-T1304
5
NM-T1305
6
NM-T1306
7
NM-T1307
Caps for Lock Attachment | Set NM-T3039 Metal Extra Soft Nylon Soft Nylon Standard Nylon High Retention
Nylon Laboratory Sealing Disc
NM-T3030 NM-T3031 NM-T3032 NM-T3033 NM-T3034 NM-T3035 NM-T1824
3.75
2.5
1.26
L
/ 63 /
Instruments
Table of Contents
/ 64 / Instruments
Drills Workflow
Page 68
Complementary Drilling Tools
Page 65
Standard / Short
Page 67
Conical
Drills Color Code
Ø 2.0
Ø 2.8
Ø 3.2
Ø 3.65
Ø 4.2
Ø 5.2
16
1311.510
86
Laser Mark
Color Code
Depth G
roove (mm
)
Page 66
Long
Material: Stainless Steel
/ 65 /
Standard DrillsØ D (mm) External Irrigation
2.0 NM-D1220
2.5 NM-D1225
2.8 NM-D1228
3.2 NM-D1232
3.65 NM-D1236
4.2 NM-D1242
5.2 NM-D1252
Drills
Short DrillsØ D (mm) External Irrigation
2.0 NM-D1420
2.8 NM-D1428
3.2 NM-D1432
3.65 NM-D1436
4.2 NM-D1442
5.2 NM-D1452
Dril
lsD
river
sTo
ols
Kits
Table of Contents
/ 66 / Instruments
Drills
Long DrillsØ D (mm) Item
2.3 NM-D7423
2.8 NM-D7428
3.2 NM-D7432
3.65 NM-D7436
Ø 2.3
Ø 2.8
Ø 3.2
Ø 3.65
Drills Color Code
25
222018
151311.5
Laser Mark
Color Code
Depth G
roove (mm
)
3.2
/ 67 /
Conical DrillsØ D1-D2 (mm) External Irrigation
1.8-2.4 NM-D3018
2.0-3.2 NM-D3020
2.5-3.7 NM-D3025
2.7-4.0 NM-D3027
2.7-4.5 NM-D3028
3.1-5.5 NM-D3031
Drills
Ø 18.-24
Ø 2.0-3.2
Ø 2.5-3.7
Ø 2.7-4.0
Ø 2.7-4.5
Ø 3.1-5.5
16
1311.51086
Laser Mark
Color Code
Depth G
roove (mm
)
D2
D1
Drills Color Code
Dril
lsD
river
sTo
ols
Kits
Table of Contents
/ 68 / Instruments
Drills
Countersink DrillsØ D (mm) Item
3.8-4.2 NM-D1034
5.0-6.0 NM-D1056
Extension DrillØ D (mm) Internal Irrigation External Irrigation
- NM-D3413 NM-D3412
Trephine DrillsØ D (mm) Item
3.0-4.0 NM-D2030
4.0-5.0 NM-D2040
5.0-6.0 NM-D2050
Marking DrillØ D (mm) Internal Irrigation External Irrigation
1.9 NM-D3411 NM-D3410
/ 69 /
Drivers for Implants
Drivers 2.42mm
Self Holding
Length (mm) Item Item
7 NM-X2607 NMHX2607
10 NM-X2610 NMHX2610
15 NM-X2615 NMHX2615
20 NM-X2620 NMHX2620
30 NM-X2630 NMHX2630
40 NM-X2640 NMHX2640
One Piece Drivers
Length (mm) D (mm) Item
10 1.7 NM-X2415
6 2.15 NM-X1018
10 2.15 NM-X1019
Motor Mounts 2.42mm
Self Holding
Length (mm) Item Item
20 NM-X1014 NMHX1014
28 NM-X1015 NMHX1015
Hand Wrench 6.35mm
Length (mm) Item
- NM-X1022
One Piece Motor Mounts Length (mm) D (mm) Item
20 1.7 NM-X1520
20 2.15 NM-X1620
Dril
lsD
river
sTo
ols
Kits
Table of Contents
/ 70 / Instruments
Drivers for Prosthetic
Drivers 1.25mm
Length (mm) Item
7 NM-X1207
10 NM-X1210
15 NM-X1215
Hand Drivers 1.25mm
Length (mm) Item
7 NM-X1006
14 NM-X1007
20 NM-X1011
Motor Mounts 1.25mm
Length (mm) Item
20 NM-X1008
25 NM-X1009
35 NM-X1010
/ 71 /
Straight Multi-Unit Motor Mounts 2.0mm
Length (mm) Item
20 NM-X1120
25 NM-X1125
Drivers for Multi-Unit & Vari-Connect
Straight Multi-Unit Drivers 2.0mm
Length (mm) Item
6 NM-X1016
10 NM-X1017
Star Hex. Drivers 1.25mm
Length (mm) Item
7 NM-X7006
14 NM-X7007
20 NM-X7011
Star Hex. Ratchet Drivers 1.25mm
Length (mm) Item
7 NM-X7307
10 NM-X7310
15 NM-X7315
Star Hex. Motor Mounts 1.25mm
Length (mm) Item
20 NM-X7008
25 NM-X7009
35 NM-X7010
Table of Contents
/ 72 / Instruments
Tools
Hand Tools
Item
Ratchet NM-X1020
Torque Ratchet NM-X1021
Surgical Screw Driver NM-X1023
Contra-Angle Torque Control HandPiece
NM-X1030
Depth Probe
Item
NM-X1025
567
3210
4
Gin
giva
l Hei
ght (
mm
)
86
1011.513
16
Osteotom
y Depth (m
m)
Material: Stainless Steel
/ 73 /
Straight Guide Pin Ø2.0mm
Length (mm) Item
10 NM-X1026
16 NM-X1027
Angulated Guide Pin Ø2.0 mm
Angle Length (mm) Item
17° 10 NM-X1302
17° 16 NM-X1312
30° 10 NM-X1304
30° 16 NM-X1314
45° 10 NM-X1305
45° 16 NM-X1315
Angulated Guide Pin Internal Hex. 2.42mm
Angle Item
17° NM-X1402
30° NM-X1404
45° NM-X1405
52° NM-X1406
60° NM-X1407
Dril
lsD
river
sTo
ols
Kits
Table of Contents
/ 74 / Instruments
Premium Surgical Kit Box
Kit NM-X2111 Contains: Kit NM-X2112 (Conical Drills) Contains:
Drill, ø2.0mm NM-D1220 Drill, ø1.8-2.4mm NM-D3018
Drill, ø2.8mm NM-D1228 Drill, ø2.0-3.2mm NM-D3020
Drill, ø3.2mm NM-D1232 Drill, ø2.5-3.7mm NM-D3025
Drill, ø3.65mm NM-D1236 Drill, ø2.7-4.0mm NM-D3027
Drill, ø4.2mm NM-D1242 Drill, ø2.7-4.5mm NM-D3028
Drill, ø5.2mm NM-D1252 Drill, ø3.1-5.5mm NM-D3031
Both Kits Contain:
Countersink, ø3.8-4.2mm NM-D1034 Motor Mount 1.25, L 20mm NM-X1008
Countersink, ø5.0-6.0mm NM-D1056 Motor Mount 2.42, L 20mm NM-X1014
Marking Drill NM-D3410 Motor Mount 2.42, L 28mm NM-X1015
Drill Extension NM-D3412 Torque Ratchet NM-X1021
Driver 1.25mm, L 7mm NM-X1207 Guide Pin, L 10mm - 2 Pcs. NM-X1026
Driver 1.25mm, L 15mm NM-X1215 Guide Pin, L 16mm - 2 Pcs. NM-X1027
Driver 2.42mm, L 7mm NM-X2607 Depth Probe NM-X1025
Driver 2.42mm, L 15mm NM-X2615 Hand Driver 1.25, L 14mm NM-X1007
/ 75 /
Mini Surgical Kit Box
Kit NM-X2211 Contains:
Drill, Countersink, ø3.8-4.2mm NM-D1034
Drill, ø2.0mm NM-D1220
Drill, ø2.8mm NM-D1228
Drill, ø3.2mm NM-D1232
Drill, ø3.65mm NM-D1236
Drill, ø4.2mm NM-D1242
Marking Drill NM-D3410
Driver 1.25mm, L 15mm NM-X1215
Driver 2.42mm, L 15mm NM-X2615
Motor Mount 1.25, L 22mm NM-X1008
Motor Mount 2.42, L 28mm NM-X1015
Ratchet NM-X1020
Guide Pin, L 10mm NM-X1026
Guide Pin, L 16mm NM-X1027
Kit NM-X2210 Contains:
Drill, Countersink, ø3.8-4.2mm NM-D1034
Drill, ø2.0mm NM-D1220
Drill, ø2.8mm NM-D1228
Drill, ø3.2mm NM-D1232
Drill, ø3.65mm NM-D1236
Drill, ø4.2mm NM-D1242
Marking Drill NM-D3410
Driver 1.25mm, L 15mm NM-X1215
Driver 2.42mm, L 15mm NM-X2615
Motor Mount 1.25, L 22mm NM-X1008
Motor Mount 2.42, L 28mm NM-X1015
Torque Ratchet NM-X1021
Guide Pin, L 10mm NM-X1026
Guide Pin, L 16mm NM-X1027
Dril
lsD
river
sTo
ols
Kits
Table of Contents
/ 76 / Instruments
Drills Kit with Stoppers
Drills diameters:
ø2.0mm, ø2.8mm, ø3.2mm
Each drill diameter has the following lengths:
6mm, 8mm, 10mm, 11.5mm, 13mm
15 Drills Set Kit NM-X2216 Contains:
Drills diameters:
ø2.0mm, ø2.5mm, ø2.8mm, ø3.2mm, ø3.65mm, ø4.2mm, ø5.2mm
Each drill diameter has the following lengths:
6mm, 8mm, 10mm, 11.5mm, 13mm
35 Drills Set Kit NM-X2212 Contains:
Drills Catalog No.:
Ø D (mm)L (mm)
2.0 2.5 2.8 3.2 3.65 4.3 5.2
6 NM-D6006 NM-D6106 NM-D6206 NM-D6306 NM-D6406 NM-D6506 NM-D6606
8 NM-D6008 NM-D6108 NM-D6208 NM-D6308 NM-D6408 NM-D6508 NM-D6608
10 NM-D6010 NM-D6110 NM-D6210 NM-D6310 NM-D6410 NM-D6510 NM-D6610
11.5 NM-D6011 NM-D6111 NM-D6211 NM-D6311 NM-D6411 NM-D6511 NM-D6611
13 NM-D6013 NM-D6113 NM-D6213 NM-D6313 NM-D6413 NM-D6513 NM-D6613
PRECISIONDOWN TO THE SMALLEST DETAIL
www.norismedical.com
LBL0
06 R
ev.2
017-
1 |
© 2
017
NO
RIS
MED
ICA
L