NomoLine - masimo.com · Infant/Neonatal, 2 mPN 4369 ... NomoLine Selection Chart Is the patient...

5
Advanced technology enables cost-effective, hassle-free sidestream capnography and gas monitoring NomoLine No-moisture sampling lines for intubated and non-intubated patients in low- and high-humidity applications

Transcript of NomoLine - masimo.com · Infant/Neonatal, 2 mPN 4369 ... NomoLine Selection Chart Is the patient...

Advanced technology enables cost-effective, hassle-free sidestream capnography and gas monitoring

NomoLine™

No-moisture sampling lines for intubated and non-intubated patients in low- and high-humidity applications

NomoLineNomoLine technology eliminates common problems associated with conventional sidestream gas analysis. Incorporating a unique, patented polymer, NomoLine allows water in the sampling line to evaporate into the surrounding air, while leaving oxygen, carbon dioxide, and anesthetic gases unaffected, eliminating the need for a water trap and issues related to their handling. Designed for low-flow applications, with functionality in any orientation, NomoLine sampling lines can be used in a variety of clinical scenarios on both intubated and non-intubated adult, pediatric, infant, and neonatal patients, in both low- and high-humidity configurations.

Features

A selection of convenient, cost-effective single-patient-use products

> Feature: Patented polymer collects and removes water in the sampling line

> Benefit: Extends product life and eliminates the need for a water trap

> Feature: Designed for low tidal volumes and high breath rates

> Benefit: Suitable for a wide range of clinical applications

> Feature: Hydrophobic bacteria filter

> Benefit: Protects the ISA™ module from bacteria and water intrusion

> Feature: Cannulas with soft, ergonomically curved design

> Benefit: Greater patient comfort

> Feature: Leak-free, click-in gas sampling port connector

> Benefit: Easy-to-use sampling lines

NomoLine LH (Low-Humidity) Single-Patient-Use Sampling LinesSingle-patient-use sampling lines for short-term applications in low-humidity conditions. Available for intubated and non-intubated patients.

NomoLine HH (High-Humidity) Single-Patient-Use Sampling LinesSingle-patient-use sampling lines for long-term applications in high-humidity conditions. Available for intubated and non-intubated patients.

NomoLine LH Airway Adapter SetKey Applications: Critical careColor coded Infant and Infant/Neonatal Airway Adapter Sets: Pink

Adult/Pediatric, 2 m PN 3814

Adult/Pediatric, 3 m PN 3815

Infant, 2 m PN 3816

Infant/Neonatal, 2 m PN 4369

NomoLine LH Single Nasal Prong CO2 CannulaKey Applications: EMS, ED

Adult single prong PN 3826

Adult PN 3817

Pediatric PN 3818

Infant PN 3819

Adult with O2 PN 3820

Pediatric with O2 PN 3821

NomoLine LH Nasal CO2 CannulaKey Applications: EMS, ED

NomoLine LH Nasal CO2 Cannula with O2 DeliveryKey Applications: EMS, ED

NomoLine LH Nasal/Oral CO2 CannulaKey Applications: Procedural sedation, critical care, sleep lab, EP, EMS, ED, cath lab

NomoLine LH Nasal/Oral CO2 Cannula with O2 DeliveryKey Applications: Procedural sedation, critical care, sleep lab, EP, EMS, ED, cath lab

Adult PN 3822

Pediatric PN 3823

Adult with O2 PN 3824

Pediatric with O2 PN 3825

NomoLine HH Airway Adapter SetKey Applications: OR, EMS, EDColor coded Infant and Infant/Neonatal Airway Adapter Sets: Pink

Adult/Pediatric, 2 m PN 3827

Adult/Pediatric, 3 m PN 3828

Infant, 2 m PN 3829

Infant/Neonatal, 2 m PN 4367

NomoLine HH Single Nasal Prong CO2 CannulaKey Applications: Critical care, sleep lab, long-term pain management

Adult single prong PN 3839

Adult PN 3830

Pediatric PN 3831

Infant PN 3832

Adult with O2 PN 3833

Pediatric with O2 PN 3834

NomoLine HH Nasal CO2 CannulaKey Applications: Critical care, sleep lab, long-term pain management

NomoLine HH Nasal CO2 Cannula with O2 DeliveryKey Applications: Critical care, sleep lab, long-term pain management

NomoLine HH Nasal/Oral CO2 CannulaKey Applications: Critical care, sleep lab, long-term pain management

NomoLine HH Nasal/Oral CO2 Cannula with O2 DeliveryKey Applications: Critical care, sleep lab, long-term pain management

Adult PN 3835

Pediatric PN 3836

Adult with O2 PN 3837

Pediatric with O2 PN 3838

INTUBATED PATIENTS Ordering Information: Box of 25, single-patient use

NON-INTUBATED PATIENTS Ordering Information: Box of 25, single-patient use

INTUBATED PATIENTS Ordering Information: Box of 25, single-patient use

NON-INTUBATED PATIENTS Ordering Information: Box of 25, single-patient use

LH HH

NomoLine Selection Chart

Is the patient intubated?

YES NO

Does the patient need supplementary oxygen?

YES NO

Short Term

Nasal/Oral Cannulawith O2 delivery

Nasal Cannula with O2 delivery

• Adult PN 3820• Pediatric PN 3821

• Adult PN 3824• Pediatric PN 3825

LH

Long Term

HH Airway Adapter Set

• Adult/Pediatric, 2 m PN 3827• Adult/Pediatric, 3 m PN 3828• Infant, 2 m PN 3829• Infant/Neonatal, 2 m PN 4367

HH

Long Term

Nasal Cannula with O2 delivery

Nasal/Oral Cannula with O2 delivery

• Adult PN 3833• Pediatric PN 3834

• Adult PN 3837• Pediatric PN 3838

HH

Short Term

Nasal Cannula Nasal/Oral Cannula Single Nasal Prong

• Adult PN 3817• Pediatric PN 3818• Infant PN 3819

• Adult PN 3822• Pediatric PN 3823

• Adult PN 3826

LH Long Term

Nasal Cannula Nasal/Oral Cannula Single Nasal Prong

• Adult PN 3830• Pediatric PN 3831• Infant PN 3832

• Adult PN 3835• Pediatric PN 3836

• Adult PN 3839

HH

Short Term

LH Airway Adapter Set

• Adult/Pediatric, 2 m PN 3814• Adult/Pediatric, 3 m PN 3815• Infant, 2 m PN 3816• Infant/Neonatal, 2 m PN 4369

LH

Color coded Infant and Neonatal Airway Adapter Sets: Pink

Masimo Internationaltel [email protected]

Masimo U.S.tel 1-877-4-Masimo [email protected] 60

443/

PLM

-103

61B-

0318

© 2018 M

asimo. A

ll rights reserved.

Masimo Sweden ABTel: +46 8 544 98 150 [email protected]

Standard length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 m

Inline bacteria filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BFE ≥ 99.9%

Tubing inner diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 mm

Supplementary oxygen delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 5 l/min

Airway Adapter dead space

Adult/Pediatric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≤ 6 ml Infant and Infant/Neonatal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 0.7 ml

Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not made with natural rubber latex

NomoLine Specifications

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. See instructions for use for full prescribing information including indications, contraindications, warnings, and precautions.

How NomoLine Works

> Gas and condensed moisture from the patient’s expired breath enters the Nomo Section through the gas sample tube

> Condensed moisture and aspirated water are separated and collected using a hydrophilic absorbent

> Water molecules are diffused from the hydrophilic absorbent through the Nomo polymer cover

> Long-term use is possible as the water diffused through the Nomo polymer cover continuously evaporates into the surrounding air

> A hydrophobic bacteria filter protects the gas module from water intrusion and cross-contamination

> Gas and condensed moisture from the patient’s expired breath enters the Nomo Section through the gas sample tube

> Condensed moisture and aspirated water are separated and collected using a hydrophilic absorbent

> When the capacity of the hydrophilic absorbent is reached, the sampling line should be replaced

> A hydrophobic bacteria filter protects the gas module from water intrusion and cross-contamination

Gas sa

mple

from

patien

t circ

uitHH

Nomo polymer cover

Hydrophobic bacteria filter

Gas sampling port connector

Gas sample tube

Hydrophilic absorbent

Nomo Section

Gas sa

mple

from

patien

t circ

uit

Hydrophobic bacteria filter

Gas sampling port connector

Gas sample tube

Hydrophilic absorbent

CoverNomo Section

LH