    Nokia BSC3i Diagnosing the BCSU

    Below are steps in troubleshooting the BCSU of a defective plug-in unit. Read notes below forESD requirements

    E ample. Replacing a plug-in unit in BCSU-!

    ". Chec# the computer unit wor#ing state.$US%&BCSU'!(

    ). %f a unit is in wor#ing state *+' change the wor#ing state to S,. fter the calls handled b the unit have ended' its state changes automaticall to S,-E/. Change the wor#ingstate first to 0E and then to SE.$USC&BCSU'!&S,($USC&BCSU'!&0E($USC&BCSU'!&SE(

    1. Switch off the cartridge power suppl .

    2. Remove the plug-in unit from the cartridge.

    3. Chec# the interchangeabilit of the new plug-in unit.

    4. Chec# the strappings of the new plug-in unit.

    5. %nsert the new plug-in unit.

    6. Switch on the cartridge power suppl .

    7. Change the computer unit wor#ing state to 0E.$USC&BCSU'!&0E(

    "!. Start the total diagnosis of the unit.$UDU&BCSU'!(

    "". Chec# the diagnostics results.$UD8&BCSU'!(

    "). Change the computer unit wor#ing state to S, 9or *+:.$USC&BCSU'!&S,(

    "1. Chec# the alarms.$ 8+(

    See figure below in inserting a plug-in unit