Noise Control Practices
Dr. Wesam Al Madhoun
![Page 2: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/2.jpg)
Noise
Before We Discuss Noise Control Let’s Review Some Noise Concepts
Noise Measurements Noise Levels are Expressed as Decibels (dB)
![Page 3: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/3.jpg)
DEVICEdBAComputer37 - 45
Refrigerator40 - 43
Cloths Dryer56 – 58
Garbage Disposal76 - 83
Vacuum Cleaner84 - 89
Leaf Blower95 - 105
Circular Saw100 - 104
![Page 4: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/4.jpg)
1+1+1 Does Not Equal to 3
The Decibel is a Logarithmic Unit of Measure So We Can’t Simply Add Numbers.
“Shake and Roll”
How We Perceive Noise
![Page 5: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/5.jpg)
![Page 6: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/6.jpg)
High Frequency Noise
Power Tools, Saws, Grinders
Other High RPM Equipment
Sudden Release of Pressure
High Frequency Noises Deflect Easier, Are Easier to Shield, Are Easier to Insulate.
![Page 7: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/7.jpg)
![Page 8: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/8.jpg)
Low Frequency Noise
Power Presses
Pumps, Compressors
Other Low RPM Equipment
Low frequency Noises Can Travel Around and Through Objects and Are Harder to Shield and Absorb
![Page 9: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/9.jpg)
![Page 10: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/10.jpg)
Harmful Effects
Harmful Effects of Noise Are Related to the Noise Dose
Is the Noise Harmful?
Ask Yourself:How Loud, How Long, How Many Times?
![Page 11: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/11.jpg)
Noise Dose is a Combination
Intensity of Noise (how loud)
Duration of Noise Exposure (how long)
Frequency (how many times during the
day are they exposed to such a noise)
![Page 12: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/12.jpg)
Noise
Regulated as an 8 hour Time
Weighted Average (TWA)
An 8 hr TWA of 90 dBA is designated
as a Noise Dose of 100%
![Page 13: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/13.jpg)
First Rule of Thumb
5 dB Halving Rule
For Each 5 dB Increase in Noise, In order
to be Equivalent to the Previous Dose You
Must Half the Allowable Exposure Time
![Page 14: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/14.jpg)
Equivalent Dose of 90 dBA Over an 8 Hour TWA Period
95 dBA over 4 Hour TWA Period
100 dBA over 2 Hour TWA Period
105 dBA over 1 Hour TWA Period
110 dBA over ½ Hour TWA Period
![Page 15: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/15.jpg)
Duration (How Long)
The 5 dB Rule Can Be Useful in
Estimating Whether a Noise or an
Activity Would Result in Employees
Being Exposed to Noise In Excess of
the PEL
![Page 16: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/16.jpg)
Example
An Employee Must Enter a Pump Room and Conduct Preventative Maintenance
The Small Portable Sound Level Meter Reads 105 dBA Inside the Pump Room
How Long Could the Employee Stay in the Pump Room Without Exceeding the Dose Equivalent Noise Exposure of 90 dBA over an 8 hour TWA?
![Page 17: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/17.jpg)
Answer
Employee Noise Exposure for 1 Hour at 105 dBA Would Be the Dose Equivalent Exposure of 90 dBA for an 8 Hr TWA
Administrative Controls Likewise, Limiting Employee Exposure Time to Noise Can Help Reduce the Possibility of Hearing Loss
![Page 18: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/18.jpg)
Watch Where You’re Standing
Employee Noise Exposures Often Depend on How Close They Are to the Noise Source
Distance
Noise Quickly Decreases as You Move Away from the Noise Source
![Page 19: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/19.jpg)
6 dB Double Distance Rule
Noise Will Decrease 6 dB Each Time You
Double the Distance (free field, point
source only)
![Page 20: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/20.jpg)
![Page 21: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/21.jpg)
6 dB Rule Would Not Apply
![Page 22: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/22.jpg)
6 dB Rule Would Not Apply
![Page 23: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/23.jpg)
Distance From the Noise Source
Is It Possible to Move the Employee Workstation or the Noise Source?
Moving the Employee or the Noise Source Doesn’t Eliminate the Loud Noise, it Just Reduces the Employee Exposure to it!
![Page 24: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/24.jpg)
Think Out Loud
In Moving the Source, Have You Created a Problem for Someone Else?
Isolation Methods
Can You Isolate the Noise Source or The Employee From the Noise Source?
![Page 25: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/25.jpg)
Enclosing the Employee
The Cab of Heavy Earth Moving Equipment
is a Good Example. They are Insulated (and
Air Conditioned).
![Page 26: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/26.jpg)
Isolation Methods
Install Barriers Between the Employee
and Noise Source
Enclose the Noise Source
Enclose the Employee
![Page 27: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/27.jpg)
Think Out Loud
Be Careful When Constructing Barriers or Enclosures.
Noise May be Deflected Backwards Off the Barriers or the Walls of the Enclosure Which Can Increase the Noise Intensity on the Noise Source Side.
Employees who Must Service Equipment or Conduct Work in Those Areas May Now be Exposed to Greater Noise than Before
![Page 28: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/28.jpg)
Deflection of Sound Waves in Enclosure Creates Louder Noise
![Page 29: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/29.jpg)
Noise Absorbing Material
The GoodNoise is Absorbed, It’s Gone, It Wouldn’t Bother Anyone Anymore
High Frequency Noises are Easier to Absorb
![Page 30: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/30.jpg)
The Bad
Some Types Can be Fragile
Some Types Can be Hard to Clean
Some Can Be Expensive
![Page 31: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/31.jpg)
The Ugly
Some Types Can Be Very Expensive
Some Types Won’t Hold Up to Chemicals or Moisture
Some Types Can be Combustible
![Page 32: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/32.jpg)
Climate
Ease of installation
Durability - resistance to degradation from
compression, moisture, decomposition, etc.
Ease of replacement at end of life
Cost effectiveness
Toxicity
Flammability
Environmental impact and sustainability
Consideration of materials used
![Page 33: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/33.jpg)
Brick
Glass
![Page 34: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/34.jpg)
Hardwood
![Page 35: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/35.jpg)
Softwood
![Page 36: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/36.jpg)
Fiberglass rigid panel
![Page 37: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/37.jpg)
PolystyreneCementitious foam
Air-entrained concrete
![Page 38: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/38.jpg)
![Page 39: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/39.jpg)
![Page 40: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/40.jpg)
Transmitting Vibration
Noise and Vibration Can Be
Transmitted to Other Surfaces Which
Then also Transmits Noise
![Page 41: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/41.jpg)
![Page 42: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/42.jpg)
Controlling Noise Generated by Vibration Sources
Springs, or Isolation Material under Motors and Large Equipment
Ensure Plates, Covers, Doors, and Access Panels are Securely Attached
Bent or Warped Shafts on Motors and Fans Can Create Vibration
Bad Bearings, Flywheels, Pulleys, Fan Blades, and Belts
![Page 43: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/43.jpg)
![Page 44: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/44.jpg)
By the Way
Poor Maintenance Can Be a Major
Source of Noise Exposure and One
Which is Often Consider Economically
Feasible.
![Page 45: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/45.jpg)
Controlling Noise Created By Released Air
Muffler systems on Pneumatic Equipment When Available
Reduce Air Pressure if Possible
Discourage the Use of Compressed Air for Cleaning Purposes
![Page 46: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/46.jpg)
You May Not Be The First Person To Ask
Contact the Manufacturer of the
Equipment and Request Assistance
in Determining Ways to Help
Decrease Noise Output of the
Machines
![Page 47: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/47.jpg)
Hearing Protection
Hearing Protection is not a Noise Control Method
Hearing Protection does not Reduce Employee Noise Exposure,
It Reduces the Potential Harm Which Could Otherwise Result in an Unprotected Employee
![Page 48: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/48.jpg)
Hearing Protectors
Like Respirators, They are Only Effective if Used Properly
Ear Plugs and Other Types of Hearing Protection Have Limitations on How Much Protection They Can Provide
![Page 49: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/49.jpg)
Noise Management Strategy
![Page 50: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/50.jpg)
The techniques employed for noise control can be broadly classified as:
Control at source
Control in the transmission path
Using protective equipment.
![Page 51: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/51.jpg)
Noise Control at Source
Reducing the noise levels from domestic
sectors:
The domestic noise coming from radio, tape
recorders, television sets, mixers, washing machines,
cooking operations can be minimized by their
selective and judicious operation.
By usage of carpets or any absorbing material, the
noise generated from felling of items in house can be
minimized.
![Page 52: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/52.jpg)
Maintenance of automobiles:
Regular servicing and tuning of vehicles will reduce the noise levels.
Fixing of silencers to automobiles, two wheelers etc., will reduce the noise levels.
Control over vibrations:
The vibrations of materials may be controlled using proper foundations, rubber padding etc. to reduce the noise levels caused by vibrations.
Low voice speaking: Speaking at low voices enough for communication reduces the excess noise levels.
![Page 53: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/53.jpg)
Prohibition on usage of loud speakers: By not permitting the usage of loudspeakers in the habitant zones except for important meetings / functions.
Selection of machinery: Optimum selection of machinery tools or equipment reduces excess noise levels.
Maintenance of machines: Proper lubrication and maintenance of machines, vehicles etc. will reduce noise levels.
For example, it is a common experience that, many parts of a vehicle will become loose while on a rugged path of journey.
![Page 54: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/54.jpg)
If these loose parts are not properly fitted, they will generate noise and cause annoyance to the driver/passenger.
Similarly is the case of machines. Proper handling and regular maintenance is essential not only for noise control but also to improve the life of machine.
Control in the transmission path
The change in the transmission path will increase the length of travel for the wave and get absorbed/refracted/radiated in the surrounding environment.
![Page 55: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/55.jpg)
Installation of barriers:
Installation of barriers between noise source and receiver can attenuate the noise levels.
For a barrier to be effective, its lateral width should extend beyond the line-of-sight at least as much as the height.
The barrier may be either close to the source or receiver, subject to the condition that, R <<D or in other words, to increase the traverse length for the sound wave.
It should also be noted that, the presence of the barrier itself can reflect sound back towards the source.
![Page 56: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/56.jpg)
At very large distances, the barrier becomes less effective because of the possibility of refractive atmospheric effects.
![Page 57: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/57.jpg)
Design of building: The design of the building incorporating the use of suitable noise absorbing material for wall/door/window/ceiling will reduce the noise levels.
The approximate reduction of outside noise levels using typical exterior wall construction is given at Table 6.
Green belt development: The degree of attenuation varies with species of greenbelt.
The typical attenuation of noise levels by trees is presented at Fig. 7 (a) and (b).
The statutory regulations direct the industry to develop greenbelt four times the built-up area for attenuation of various atmospheric pollutants, including noise.
![Page 58: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/58.jpg)
![Page 59: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/59.jpg)
![Page 60: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/60.jpg)
Using protection equipment
Protective equipment usage is the ultimate step in noise control technology, i.e. after noise reduction at source
and/or after the diversion or engineered control of transmission path of noise.
The first step in the technique of using protective equipment is to gauge the intensity of the problem, identification of the sufferer and his exposure to the noise levels.
The usage of protective equipment and the worker's exposure to the high noise levels can be minimized by -:
Job rotation: By rotating the job between the workers working at a particular noise source or isolating a person, the adverse impacts can be reduced.
![Page 61: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/61.jpg)
Exposure reduction: Regulations prescribe that, noise level of 90 dB (A) for more than 8 hr continuous exposure is prohibited.
Persons who are working under such conditions will be exposed to occupational health hazards.
The schedule of the workers should be planned in such a way that, they should not be over exposed to the high noise levels.
Hearing protection: Equipment like earmuffs, ear plugs etc. are the commonly used devices for hearing protection.
Attenuation provided by ear-muffs vary widely in respect to their size, shape, seal material etc.
Literature survey shows that, an average noise attenuation up to 32 dB can be achieved using earmuffs.
![Page 62: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/62.jpg)
Traffic Control Measures
Reducing road traffic noise at source:(a)imposing permissible noise emission limits;
(b) promoting the use of public transport; and
(c) cracking down illegal vehicle modifications such as muffler alterations
Land use planning:(a)zoning land and planning urban projects with the consideration of the noise factor;
(b) building bypasses and ring roads; and
(c) establishing buffer zones on each side of a road.
![Page 63: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/63.jpg)
Resurfacing roads with low-noise materials:
Resurfacing roads with low-noise materials to reduce noise from tire friction.
Generally speaking, low-noise pavement can attain a reduction of noise from 3 dB(A) to 5 dB(A).
Installing double-glazed windows and air-conditioning for the affected residents
Adopting advanced construction methods
employing a jointless construction method for elevated roads and bridges; and
installing sound-absorbing panels on the underside of elevated roads.
![Page 64: Noise Control Practices](https://reader036.fdocuments.us/reader036/viewer/2022062309/56813514550346895d9c68eb/html5/thumbnails/64.jpg)
Prohibition of certain vehicle types (usually trucks)
from a particular route or restricting vehicles from
operating during noise sensitive times of the day.
The prohibition of trucks from a major roadway can
produce up to an 8 to 10 dB reduction in noise, at
times providing an adequate traffic management
abatement measure.