NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

267
C20 Converged Softswitch Logs and Alarms Reference, Volume 9 Release: CVM16 and up Document Revision: 12.01 www.genband.com NN10275-909v9

Transcript of NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Page 1: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

C20 Converged Softswitch

Logs and Alarms Reference,Volume 9Release: CVM16 and upDocument Revision: 12.01

www.genband.com

NN10275-909v9

Page 2: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

C20 Converged SoftswitchRelease: CVM16 and upPublication: NN10275-909v9Document status: StandardDocument release date: 03 October 2011

Copyright © 2011 GENBAND. All rights reserved. Use of this documentation and its contents is subject to theterms and conditions of the applicable end user or software license agreement, right to use notice, and all relevantcopyright protections.

GENBAND, the GENBAND corporate logo and tagline, and certain of GENBAND's product and solution namesare registered trademarks of GENBAND and its affiliates.

While the information in this document is believed to be accurate and reliable, except as otherwise expresslyagreed to in writing GENBAND AND/OR ITS LICENSORS PROVIDES THIS DOCUMENT "AS IS" WITHOUTWARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or productsdescribed in this document are subject to change without notice.

THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF GENBAND OR ITS LICENSORS ANDMUST NOT BE DISCLOSED, OTHER THAN TO EMPLOYEES OF GENBAND OR CUSTOMERS WITH NEED-TO-KNOW, WITHOUT THE PRIOR WRITTEN CONSENT OF GENBAND OR ITS LICENSORS. THEINFORMATION MUST NOT BE DISCLOSED TO SUBCONTRACTORS OR REGULATORY AUTHORITIES. GENBAND MUST BE NOTIFIED OF ANY REQUEST OR ORDER FOR DISCLOSURE PRIOR TO SUCHDISCLOSURE.

Software and documentation owned by or under license with Nortel Networks included in this Release or in anydocument provided with this Release is Copyright © 2010 Nortel Networks or its licensors. All rights reserved. Useof this software and/or documentation and its contents is subject to the terms and conditions of the applicable enduser or software license agreement, right to use notice, and all relevant copyright protections. The product names remain as Carrier VoIP and CS 2000 in Canada and France pending regulatory approvals for a name change.

Page 3: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Contents

New in this release 17VSECA_alarm 17XAC 17

Logs and alarms fundamentals 19

VSECA_alarm alarms and logs reference 21VCA1300 21

Remedial action 21Attributes 21

VCA1301 22Remedial action 22Attributes 22

VCA1302 22Remedial action 22Attributes 22

VCA1303 22Remedial action 23Attributes 23

VCA1304 23Remedial action 23Attributes 23

VCA1305 24Remedial action 24Attributes 24

VCA1306 24Remedial action 24Attributes 24

VCA1307 25Remedial action 25Attributes 25

VCA1308 25Remedial action 25Attributes 25

VCA1309 25Remedial action 26Attributes 26

XAC alarms and logs reference 27

3

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 4: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CAP100 27Remedial action 28Attributes 28Format 28Selected field descriptions 28Active message example 29Clear message example 29Associated OM registers 29

CAP101 29Remedial action 30Attributes 30Format 30Selected field descriptions 30Active message example 32Clear message example 32Associated OM registers 33

CAP102 33Remedial action 33Attributes 34Format 34Selected field descriptions 34Active message example 35Clear message example 36Associated OM registers 36

CAP103 36Remedial action 37Attributes 37Format 37Selected field descriptions 37Active message example 38Clear message example 38Associated OM registers 38

LOST110 38Remedial action 39Attributes 39Format 39Selected field descriptions 40Active message example 40Clear message example 41Associated OM registers 41

LOST111 41Remedial action 41Attributes 42Format 42Selected field descriptions 42Active message example 43Clear message example 44Associated OM registers 44

LOST116 44Remedial action 44

4

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 5: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Attributes 44Format 45Selected field descriptions 45Active message example 46Clear message example 46Associated OM registers 47

LOST117 47Remedial action 47Attributes 47Format 47Selected field descriptions 48Active message example 48Clear message example 49Associated OM registers 49

SOS701 49Remedial action 50Attributes 50Format 50Active message example 50Clear message example 50Associated OM registers 50

SOS702 50Remedial action 51Attributes 51Format 51Active message example 51Clear message example 51Associated OM registers 51

SOS703 51Remedial action 52Attributes 52Format 52Active message example 52Clear message example 52Associated OM registers 52

XAC300 52Remedial action 53Attributes 53Format 53Selected field descriptions 54Active message example 57Clear message example 58Associated OM registers 58

XAC302 58Remedial action 59Attributes 59Format 59Selected field descriptions 60Active message example 63Clear message example 64

5

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 6: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers 64XAC303 64

Remedial action 65Attributes 66Format 66Selected field descriptions 66Active message example 70Clear message example 70Associated OM registers 70

XAC304 70Remedial action 71Attributes 72Format 72Selected field descriptions 73Active message example 76Clear message example 77Associated OM registers 77

XAC305 77Remedial action 77Attributes 79Format 79Selected field descriptions 79Active message example 83Clear message example 83Associated OM registers 83

XAC306 83Remedial action 84Attributes 84Format 84Selected field descriptions 85Active message example 88Clear message example 88Associated OM registers 88

XAC307 88Remedial action 89Attributes 89Format 89Selected field descriptions 90Active message example 93Clear message example 93Associated OM registers 93

XAC308 93Remedial action 94Attributes 94Format 94Selected field descriptions 95Active message example 97Clear message example 98Associated OM registers 98

XAC309 98

6

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 7: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial action 99Attributes 99Format 99Selected field descriptions 100Active message example 103Clear message example 104Associated OM registers 104

XAC310 104Remedial action 104Attributes 104Format 104Selected field descriptions 104Active message example 106Clear message example 107Associated OM registers 107

XAC312 107Remedial action 107Attributes 107Format 107Selected field descriptions 108Active message example 111Clear message example 112Associated OM registers 112

XAC320 112Remedial action 113Attributes 114Format 114Selected field descriptions 114Active message example 115Clear message example 116Associated OM registers 116

XAC321 116Remedial action 117Attributes 117Format 117Selected field descriptions 117Active message example 118Clear message example 119Associated OM registers 119

XAC322 119Remedial action 119Attributes 120Format 120Selected field descriptions 120Active message example 123Clear message example 124Associated OM registers 124

XAC323 124Remedial action 124Attributes 125

7

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 8: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Format 125Selected field descriptions 125Active message example 128Clear message example 129Associated OM registers 129

XAC324 129Remedial action 130Attributes 130Format 130Selected field descriptions 131Active message example 134Clear message example 134Associated OM registers 134

XAC325 134Remedial action 135Attributes 135Format 135Selected field descriptions 135Active message example 137Clear message example 137Associated OM registers 137

XAC326 137Remedial action 138Attributes 138Format 138Selected field descriptions 138Active message example 140Clear message example 141Associated OM registers 141

XAC327 141Remedial action 141Attributes 141Format 141Selected field descriptions 142Active message example 142Clear message example 143Associated OM registers 143

XAC329 143Remedial action 143Attributes 144Format 144Selected field descriptions 145Active message example 148Clear message example 149Associated OM registers 149

XAC330 149Remedial action 149Attributes 149Format 149Selected field descriptions 150

8

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 9: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example 150Clear message example 151Associated OM registers 151

XAC333 151Remedial action 152Attributes 152Format 152Selected field descriptions 153Active message example 153Clear message example 154Associated OM registers 154

XAC335 154Remedial action 154Attributes 154Format 154Active message example 155Clear message example 155Associated OM registers 155

XAC337 155Remedial action 155Attributes 156Format 156Selected field descriptions 156Active message example 158Clear message example 158Associated OM registers 158

XAC400 158Remedial action 158Attributes 158Format 159Selected field descriptions 160Active message example 161Clear message example 162Associated OM registers 162

XAC413 162Remedial action 163Attributes 163Format 163Selected field descriptions 163Active message example 164Clear message example 164Associated OM registers 164

XAC415 164Remedial action 164Attributes 165Format 165Selected field descriptions 166Active message example 167Clear message example 169Associated OM registers 169

9

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 10: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

XAC418 169Remedial action 170Attributes 170Format 170Selected field descriptions 170Active message example 171Clear message example 171Associated OM registers 171

XAC420 171Remedial action 172Attributes 172Format 172Selected field descriptions 172Active message example 174Clear message example 175Associated OM registers 175

XAC600 175Remedial action 175Attributes 175Format 175Selected field descriptions 176Active message example 178Clear message example 178Associated OM registers 178

XAC601 178Remedial action 178Attributes 178Format 178Selected field descriptions 179Active message example 179Clear message example 179Associated OM registers 179

XAC602 179Remedial action 179Attributes 179Format 179Selected field descriptions 180Active message example 182Clear message example 182Associated OM registers 182

XAC603 182Remedial action 182Attributes 182Format 183Selected field descriptions 183Active message example 185Clear message example 185Associated OM registers 185

XAC604 185Remedial action 185

10

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 11: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Attributes 186Format 186Selected field descriptions 186Active message example 188Clear message example 188Associated OM registers 188

XAC605 188Remedial action 189Attributes 189Format 189Selected field descriptions 189Active message example 191Clear message example 191Associated OM registers 191

XAC606 192Remedial action 192Attributes 192Format 192Selected field descriptions 192Active message example 194Clear message example 194Associated OM registers 195

XAC607 195Remedial action 195Attributes 195Format 195Selected field descriptions 195Active message example 197Clear message example 198Associated OM registers 198

XAC608 198Remedial action 198Attributes 198Format 198Selected field descriptions 198Active message example 198Clear message example 198Associated OM registers 199

XAC609 199Remedial action 199Attributes 199Format 199Selected field descriptions 199Active message example 201Clear message example 202Associated OM registers 202

XAC610 202Remedial action 202Attributes 202Format 202

11

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 12: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptions 203Active message example 205Clear message example 205Associated OM registers 206

XAC612 206Remedial action 206Attributes 206Format 206Selected field descriptions 206Active message example 208Clear message example 208Associated OM registers 209

XAC613 209Remedial action 209Attributes 209Format 209Selected field descriptions 209Active message example 209Clear message example 210Associated OM registers 210

XAC614 210Remedial action 210Attributes 210Format 210Selected field descriptions 210Active message example 211Clear message example 211Associated OM registers 211

XAC615 211Remedial action 211Attributes 211Format 211Selected field descriptions 211Active message example 212Clear message example 212Associated OM registers 212

XAC618 212Remedial action 212Attributes 213Format 213Selected field descriptions 213Active message example 214Clear message example 214Associated OM registers 214

XAC619 214Remedial action 215Attributes 215Format 215Selected field descriptions 215Active message example 215

12

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 13: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message example 215Associated OM registers 215

XAC620 215Remedial action 216Attributes 216Format 216Selected field descriptions 216Active message example 218Clear message example 218Associated OM registers 218

XAC622 218Remedial action 218Attributes 218Format 218Selected field descriptions 219Active message example 221Clear message example 221Associated OM registers 221

XAC623 221Remedial action 221Attributes 221Format 221Selected field descriptions 222Active message example 224Clear message example 224Associated OM registers 224

XAC624 224Remedial action 224Attributes 224Format 224Selected field descriptions 225Active message example 227Clear message example 227Associated OM registers 227

XAC625 227Remedial action 227Attributes 228Format 228Selected field descriptions 228Active message example 229Clear message example 229Associated OM registers 230

XAC626 230Remedial action 230Attributes 230Format 230Selected field descriptions 231Active message example 232Clear message example 233Associated OM registers 233

13

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 14: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

XAC627 233Remedial action 233Attributes 233Format 233Selected field descriptions 233Active message example 234Clear message example 234Associated OM registers 234

XAC628 234Remedial action 234Attributes 235Format 235Selected field descriptions 235Active message example 237Clear message example 237Associated OM registers 237

XAC629 237Remedial action 238Attributes 238Format 238Selected field descriptions 238Active message example 240Clear message example 240Associated OM registers 240

XAC630 240Remedial action 241Attributes 241Format 241Selected field descriptions 241Active message example 242Clear message example 242Associated OM registers 242

XAC631 242Remedial action 242Attributes 242Format 242Selected field descriptions 243Active message example 243Clear message example 243Associated OM registers 243

XAC632 243Remedial action 244Attributes 244Format 244Selected field descriptions 245Active message example 245Clear message example 245Associated OM registers 246

XAC633 246Remedial action 246

14

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 15: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Attributes 246Format 246Selected field descriptions 246Active message example 247Clear message example 247Associated OM registers 247

XAC634 247Remedial action 247Attributes 247Format 247Selected field descriptions 248Active message example 248Clear message example 248Associated OM registers 248

XAC635 248Remedial action 249Attributes 249Format 249Selected field descriptions 249Active message example 250Clear message example 250Associated OM registers 250

XAC637 250Remedial action 250Attributes 250Format 250Selected field descriptions 251Active message example 251Clear message example 251Associated OM registers 251

XAC640 251Remedial action 251Attributes 251Format 251Selected field descriptions 252Active message example 253Clear message example 253Associated OM registers 253

XAC641 253Remedial action 254Attributes 254Format 254Selected field descriptions 254Active message example 254Clear message example 255Associated OM registers 255

XAC801 255Remedial action 255Attributes 255Format 255

15

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 16: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptions 256Active message example 256Clear message example 256Associated OM registers 257

XAC814 257Remedial action 257Attributes 257Format 257Selected field descriptions 258Active message example 258Clear message example 258Associated OM registers 259

XACP300 259Remedial action 259Attributes 259Format 259Selected field descriptions 260Active message example 260Clear message example 260Associated OM registers 260

XACP310 260Remedial action 261Attributes 261Format 261Selected field descriptions 261Active message example 261Clear message example 262Associated OM registers 262

XACP500 262Remedial action 262Attributes 262Format 262Selected field descriptions 262Active message example 263Clear message example 263Associated OM registers 263

XACP600 263Remedial action 263Attributes 263Format 263Selected field descriptions 265Active message example 265Clear message example 266Associated OM registers 266

16

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 17: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

New in this release

The following sections detail what's new in the following network elementsand applications for this release.

VSECA_alarm• VCA1300 modified

• VCA1301 modified

• VCA1302 modified

• VCA1303 modified

• VCA1304 modified

• VCA1305 modified

• VCA1306 modified

• VCA1307 modified

• VCA1308 modified

• VCA1309 modified

XACNo Changes for this device

17

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 18: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

18 New in this release

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 19: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Logs and alarms fundamentals

A log report is a message about an important conditions or events relatedto component(s) performance. Log reports include, but are not restrictedto, the following information:

• state and activity reports

• changes in state

• hardware or software errors

• test results

• other events or conditions that affect performance

Both system actions and manual overrides can generate log reports.

Attention: This document uses multiple volumes to describe logs thatthe C20 network components can generate. Not all components apply toevery solution.

Attention: In systems which include an Integrated ElementManagement System (IEMS), clearing of manually clearable alarmsthrough OMI (or a System Management GUI) is reflected in the IEMS.However, acknowledgement of alarms through OMI (or a SystemManagement GUI) is NOT reflected in the IEMS.

19

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 20: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

20 Logs and alarms fundamentals

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 21: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

VSECA_alarm alarms and logsreference

This section provides a reference for the VSECA_alarm alarms and logsfor the VSECA14.0 release.

VCA1300VCA Network File System Inactive core Indicator Key (Niikey). This alarmis raised when Niikey is enabled for the VSECA application during acutover procedure.

Niikey is used by Nortel Installation Services personnel during cutoverprocedures. It indicates that the Network File System (NFS) inactive coreindicator key (Niikey) was detected as enabled. If a SOS application rebootoccurs while the Niikey is set, the SOS application will be prevented frombecoming the active instance.

Remedial actionIf a cutover is not in progress for the VSECA and this alarm appears,contact your next level of support. Otherwise, at the end of the cutoverprocedure, use the cli to disable Niikey for the VSECA application.

If a cutover is not in progress and this alarm appears, contact your nextlevel of support. Otherwise, at the end of the cutover procedure, use the clito disable Niikey for the VSECA application.

AttributesAttribute Value

Log name VCA1300

Type Quality of Service Alarm

Associated component VSE_Call_Agent application

21

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 22: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

VCA1301

Remedial actionInvestigate the cause of the out-of-sync condition. Then, use the cli 'sync'command to sync the VCA application.

Investigate the cause of the out-of-sync condition. Then, use the 'vca sync'cli command to clear the condition or wait for the system to automaticallyre-establish synchronization.

AttributesAttribute Value

Log name VCA1301

Type Processing Error Alarm

Associated component VSE_Call_Agent application

VCA1302When this alarm is raised, it indicates that the VSECA application isundergoing a RExTst. The RExTst can be initiated manually from the cli, orautomatically by the system.

RExTst runs in one of two modes: Base or Full. Base RExTst steps: imagetest and sync. Full RExTst steps: image test, hardware diagnostics andboard reset, sync, swact, and sync. Base RExTst is usually scheduled 6times a week at night during low traffic. Full RExTst is scheduled once perweek. Manual RExTst can be run by craft personnel at any time.

Remedial actionNo repair action required.

No manual action is required. The alarm clears automatically once theRExTst has completed.

AttributesAttribute Value

Log name VCA1302

Type Quality of Service Alarm

Associated component VSE_Call_Agent application

VCA1303One or more manual or system-initiated RExTsts have failed or have beenmanually aborted.

22 VSECA_alarm alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 23: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

This alarm is raised if any of the steps involved in the manual or systeminitiated RExTst fails.

Remedial actionReview office records to determine if the fault has occurred in the past.Run a manual RExTst during a period of low traffic to determine if the faultis intermittent. The alarm clears after a successful RExTst is completed(manual or system initiated).

Review office records to determine if the fault has occurred in the past.Run a manual RExTst during a period of low traffic to determine if the faultis intermittent. The alarm clears after a successful RExTst is completed(manual or system initiated).

AttributesAttribute Value

Log name VCA1303

Type Processing Error Alarm

Associated component VSE_Call_Agent application

VCA1304VSECA RExTst was not automatically scheduled by the system in the last7 days.

Once a RExTst is automatically scheduled by the system, the alarm clearsautomatically.

Remedial actionCheck SOS IOAU112 logs to see if a system RExTst has been disabled. Ifit has, no action is required. If system RExTst has not been disabled, editSOS table REXSCHED so that automatic scheduling of RExTst isresumed.

Check the SOS IOAU112 log reports to see if system RExTst has beendisabled. If it has, no action required. If system RExTst has not beendisabled, edit SOS table REXSCHED so that automatic scheduling ofRExTst is resumed.

AttributesAttribute Value

Log name VCA1304

Type Quality of Service Alarm

Associated component VSE_Call_Agent application

VCA1304 23

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 24: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

VCA1305VSECA Image Test (ImgTst) is in progress for the VSECA application.

ImgTst can be manually initiated from the cli, or as part of a manual orsystem RExTst. During ImgTst, all SOS restart types (warm, cold andreload) are performed on the standby instance of the VSECA application.

Remedial actionNo repair action required.

No manual action required. The alarm clears once the ImgTst completes.

AttributesAttribute Value

Log name VCA1305

Type Quality of Service Alarm

Associated component VSE_Call_Agent application

VCA1306One or more ImgTsts have failed. The ImgTst can be manually initiatedfrom the cli, or as part of a system or manual initiated RExTst.

This alarm is raised if the standby instance of the VSECA applicationcannot be successfully restarted (warm, cold or reload).

Remedial actionThe alarm clears once a successful ImgTst completes. The ImgTst can bemanually initiated from the cli, or as part of a system or manual RExTst.Run a manual ImgTst during a period of low traffic to determine if the faultis intermittent. The alarm clears after a successful ImgTst has completed.

The alarm clears once a successful ImgTst completes. The ImgTst can bemanually initiated from the cli, or as part of a system or manual RExTst.Run a manual ImgTst during a period of low traffic to determine if the faultis intermittent. The alarm clears after a successful ImgTst has completed.

AttributesAttribute Value

Log name VCA1306

Type Processing Error Alarm

Associated component VSE_Call_Agent application

24 VSECA_alarm alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 25: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

VCA1307VSECA Call Processing Applicaton Out of Service

This alarm is raised if the call processing application instance is out ofservice.

Remedial actionThe alarm clears once the call processing application is in service.

The alarm clears once the call processing applicatoin instance is inservice.

AttributesAttribute Value

Log name VCA1307

Type Processing Error Alarm

Associated component VSE_Call_Agent application

VCA1308Low memory condition of the call processing application instance.

This alarm is raised during a low memory condition of the call processingapplication instance

Remedial actionThe alarm clears automatically once the memory usage of the callprocessing application instance resumes to normal.

The alarm clears once the memory usage of the call processing applicationresumes to normal.

AttributesAttribute Value

Log name VCA1308

Type Processing Error Alarm

Associated component VSE_Call_Agent application

VCA1309Message Controller is undergoing a RExTst. The RExTst can be initiatedmanually from the cli, or by the system.

VCA1309 25

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 26: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

MC RExTst which is scheduled once per week includes board reset andhardware diagnostics. Manual RExTst can be run by craft at any time.

Remedial actionNo repair action required.

No manual action required. The alarm clears once the RExTst completes.

AttributesAttribute Value

Log name VCA1309

Type Processing Error Alarm

Associated component VSE_Call_Agent application

26 VSECA_alarm alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 27: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

XAC alarms and logs reference

This section provides a reference for the XAC alarms and logs for theCORE13 release.

CAP100The CAP100 log provides a summary of the system''''''''s capacity usage forthe previous 15 minutes. It provides averages of the numerical datareported at the CAPACITY MAP level during 15-minute sample. (Thefollowing figure shows the location of the CAPACITY level in the hierarchyof MAP levels.)

The log generates once every 15 minutes when activated by theSTRTLOG command.

Location of the CAPACITY MAP level

Event type: Informational (INFO).

The CAP-log buffer is a circular buffer. When the buffer has filled up, eachnew CAP log report overwrites the oldest CAP log report in the buffer.When you display the CAP log reports using LOGUTIL or DLOG, you mayencounter one or more instances of the message, "Log not available oroverwritten due to log throttling." This message is displayed if a log reportin the buffer is so old that it no longer makes sense, or if a log report isincomplete because it has been overwritten by new data.

The CAP log buffer can hold up to three hours'''''''' worth of CAP logreports.

27

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 28: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The three hours need not be three consecutive hours. For example, if youdisable CAP logs for a length of time and then enable them again, the logreports in the buffer will be from non-consecutive hours.

CAP log reports survive warm and cold restarts.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatSwitch Reportid mmmdd hh:mm:ss ssdd Event type Log title

CATMP/HR<nn>UTIL<nn>ENGCATMP<nn>MAXCATMP<nn>

Selected field descriptionsField Value Fixed or

VariableDescription

Switch TYPE= Variable Identifies the switch

Reportid CAP100 Variable The Reportid field displays the loggroup (CAP) and identification numberof the log report.

Event INFO Variable The Event Type displays the type ofevent identified in the log report.

Log CAPACITY_SUMMARY

Variable The Reportid field displays the loggroup and identification number of thelog report.

CATMP/HR Numeric Variable Call attempts per hour.

UTIL Numeric Variable A percentage representing thesummary of capacity activity for thelast 15 minutes.

28 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 29: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ENGCATMP Numeric Variable Projected engineered call attemptsper hour at which all grade-of-servicespecifications are met. This value isbased on the Rated Power of theoffice, and does not take theprocessing power of the spare PE intoaccount.

MAXCATMP Numeric Variable Projected maximum call attempts perhour at which all grade-of-servicespecifications are met. This valueincludes all PEs, including thoseprovisioned for reliability.

Active message exampleMTXJ10AF CAP100 JUN26 12:47:19 6000 INFO CAPACITY_SUMMARY

CATMP/HR 120000 UTIL 75 ENGCATMP 160000 MAXCATMP 2000000

Clear message examplen/a

Associated OM registers

CAP101The CAP101 log provides the user data reported at the CAPACITY MAPlevel. (The following figure shows the location of the CAPACITY level in thehierarchy of MAP levels.)

The log generates three times every 15 minutes. Each time it generates, itprovides information about the previous five minutes. The informationrefers to five one-minute intervals.

The log activates when the user enters the STRTLOG command.

Location of the CAPACITY MAP level

Event type: Informational (INFO).

CAP101 29

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 30: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The CAP-log buffer is a circular buffer. When the buffer has filled up, eachnew CAP log report overwrites the oldest CAP log report in the buffer.When you display the CAP log reports using LOGUTIL or DLOG, you mayencounter one or more instances of the message, "Log not available oroverwritten due to log throttling." This message is displayed if a log reportin the buffer is so old that it no longer makes sense, or if a log report isincomplete because it has been overwritten by new data.

The CAP log buffer can hold up to three hours' worth of CAP log reports.

The three hours need not be three consecutive hours. For example, if youdisable CAP logs for a length of time and then enable them again, the logreports in the buffer will be from non-consecutive hours.

CAP log reports survive warm and cold restarts.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatSwitch Reportid mmmdd hh:mm:ss ssdd Event type Log title

<min.>: CATMP/HR<nn>UTIL<nn>ENGCATMP<nn>MAXCATMP<nn>

ENGLEVEL<ABOVE|BELOW>CCOVRLD<ON|OFF>IOOVRLD<OFF|CMIC|ETHR|CMIC-ETHR>

PESC<YES|NO>

Selected field descriptionsField Value Fixed or

VariableDescription

Switch TYPE="text" Variable Identifies the switch

Reportid CAP101 Variable The Reportid field displays the loggroup (CAP) and identification numberof the log report.

30 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 31: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Event INFO Variable The Event Type displays the type ofevent identified in the log report.

Log CAPACITY_DATA Variable The Reportid field displays the loggroup and identification number of thelog report.

CATMP/HR Numeric Variable Call attempts per hour.

UTIL Numeric Variable Current call attempts as a percentageof engineered call attempts.

ENGCATMP Numeric Variable Projected engineered call attemptsper hour at which all grade-of-servicespecifications are met. This value isbased on the Rated Power of theoffice, and does not take theprocessing power of the spare PE intoaccount.

MAXCATMP Numeric Variable Projected maximum call attempts perhour at which all grade-of-servicespecifications are met. This valueincludes all PEs, including thoseprovisioned for reliability.

ENGLEVEL ABOVE Variable Boolean, indicating whether utilizationis above or below the value set foroffice parameterCC_ENGLEVEL_WARNING_THRESHOLD.

CCOVRLD ON Variable Boolean, indicating the status of thecentral control overload controls.

IOOVRLD OFF Variable Indicates the status of the IO overloadcontrols. The system monitors theusage of the CMIC and ethernetmessaging. When the messaging rateexceeds a threshold, the systemactivates overload control. Whenactivated, overload control causes thesystem to reject new call originations.The system deactivates overloadcontrol when the messaging ratedeclines to a rate that does notexceed the threshold. The value CMICindicates that the CMIC messagingrate has exceeded the CMICmessaging threshold, causing thesystem to activate CMIC overloadcontrol. The value ETHR indicates

CAP101 31

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 32: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

that the ethernet messaging rate hasexceeded the ethernet messagingthreshold, causing the system toactivate ethernet overload control. Thevalue CMIC-ETHR indicates that theCMIC messaging rate has exceededthe CMIC messaging threshold andthe ethernet messaging rate hasexceeded the ethernet messagingthreshold, causing the system toactivate CMIC overload control andethernet overload control.

PESC YES Variable Boolean, indicating whether a PEstate change occurred.

Active message exampleMTXJ10AF CAP101 JUN26 12:47:19 6000 INFO CAPACITY DATA

11: CATMP/HR 120000 UTIL 75 ENGCATMP 160000 MAXCATMP 200000

ENGLEVEL BELOW CCOVRLD OFF IOOVRLD OFF PESC NO

12: CATMP/HR 112000 UTIL 70 ENGCATMP 160000 MAXCATMP 200000

ENGLEVEL BELOW CCOVRLD OFF IOOVRLD OFF PESC NO

13: CATMP/HR 112000 UTIL 70 ENGCATMP 160000 MAXCATMP 200000

ENGLEVEL BELOW CCOVRLD OFF IOOVRLD OFF PESC NO

14: CATMP/HR 120000 UTIL 75 ENGCATMP 160000 MAXCATMP 200000

ENGLEVEL BELOW CCOVRLD OFF IOOVRLD OFF PESC NO

14: CATMP/HR 120000 UTIL 75 ENGCATMP 160000 MAXCATMP 200000

ENGLEVEL BELOW CCOVRLD OFF IOOVRLD OFF PESC NO

Clear message examplen/a

32 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 33: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

CAP102The CAP102 log provides the user data reported at the SCHEDMAP MAPlevel. (The following figure shows the location of the SCHEDMAP level inthe hierarchy of MAP levels.)

The log generates three times every 15 minutes. Each time it generates, itprovides information about the previous five minutes. The informationrefers to five one-minute intervals.

The log activates when the user enters the STRTLOG command.

Location of the SCHEDMAP MAP level

Event type: Informational (INFO).

The CAP-log buffer is a circular buffer. When the buffer has filled up, eachnew CAP log report overwrites the oldest CAP log report in the buffer.When you display the CAP log reports using LOGUTIL or DLOG, you mayencounter one or more instances of the message, "Log not available oroverwritten due to log throttling." This message is displayed if a log reportin the buffer is so old that it no longer makes sense, or if a log report isincomplete because it has been overwritten by new data.

The CAP log buffer can hold up to three hours' worth of CAP log reports.

The three hours need not be three consecutive hours. For example, if youdisable CAP logs for a length of time and then enable them again, the logreports in the buffer will be from non-consecutive hours.

CAP log reports survive warm and cold restarts.

Remedial actionn/a

CAP102 33

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 34: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatSwitch Reportid mmmdd hh:mm:ss ssdd Event type Log title

<min.>: SCHED<n>FORE<n>MAINT<n>DNC<n>AUXCP<n>

OM<n>GTERM<n>BKG<n>NETM<n>SNIP<n>IO<n>

Selected field descriptionsField Value Fixed or

VariableDescription

GTERM numeric Variable Percentage indicating observedGTERMCLASS utilization relative tothe expected occupancy at capacity.This value can be altered via the officeparmGUARANTEED_TERMINAL_CPU_SHARE

BKG numeric Variable Percentage indicating observedbackground classes utilization relativeto the expected occupancy atcapacity. Background includesBKGCLASS and AUDITCLASS

NETM numeric Variable Percentage indicating observedNETMTCCLASS utilization relative tothe expected occupancy allocated atcapacity

SNIP numeric Variable Percentage indicating observedSNIPCLASS utilization relative to theexpected occupancy at capacity

IO numeric Variable Percentage indicating IO utilization, asa proportion of the expected maximumIO utilization.

Switch TYPE="text" Variable Identifies the switch

Reportid CAP102 Variable The Reportid field displays the loggroup (CAP) and identification numberof the log report.

Event INFO Variable The Event Type displays the type ofevent identified in the log report.

34 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 35: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Log CAPACITY_SCHEDMAP

Variable The Reportid field displays the loggroup and identification number of thelog report.

SCHED numeric Variable Percentage indicating observedscheduler overhead utilization relativeto the expected overhead occupancyat capacity

FORE numeric Variable Percentage indicating observedoperating system utilization relative tothe expected occupancy at capacity.Foreground includes SYSTEMCLASS,SYSTOOLCLASS, INITCLASS.

MAINT numeric Variable Percentage indicating observedMAINTCLASS utilization relative tothe expected occupancy at capacity

DNC numeric Variable Percentage indicating observedNOSFTCLASS utilization relative tothe expected occupancy allocated atcapacity. DNC includes NOSFT class

AUXCP numeric Variable Percentage indicating observedAUXCPCLASS utilization relative tothe expected occupancy at capacity.This value can be altered via the officeparm AUXCP_CPU_SHARE

OM numeric Variable Percentage indicating observed OMutilization relative to the expectedoccupancy at capacity. OM includesGOMCLASS and NGOMCLASS

Active message exampleMTXJ10AF CAP102 AUG16 16:53:13 3400 INFO CAPACITY_SCHEDMAP

11: SCHED 85 FORE 75 MAINT 80 DNC 66 AUXCP 100

OM 95 GTERM 50 BKG 300 NETM 0 SNIP 20 IO 0

12: SCHED 85 FORE 75 MAINT 80 DNC 66 AUXCP 100

OM 95 GTERM 50 BKG 300 NETM 0 SNIP 20 IO 0

13: SCHED 85 FORE 75 MAINT 80 DNC 66 AUXCP 100

OM 95 GTERM 50 BKG 300 NETM 0 SNIP 20 IO 0

CAP102 35

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 36: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

14: SCHED 85 FORE 75 MAINT 80 DNC 66 AUXCP 100

OM 95 GTERM 50 BKG 300 NETM 0 SNIP 20 IO 0

15: SCHED 85 FORE 75 MAINT 80 DNC 66 AUXCP 100

OM 95 GTERM 50 BKG 300 NETM 0 SNIP 20 IO 0

Clear message examplen/a

Associated OM registers

CAP103The CAP103 log provides the user data reported at the DETAIL MAP level.(The following figure shows the location of the DETAIL level in thehierarchy of MAP levels.)

The log generates three times every 15 minutes. Each time it generates, itprovides information about the previous five minutes. The informationrefers to five one-minute intervals.

The log activates when the user enters the STRTLOG command.

Location of the DETAIL MAP level

Event type: Informational (INFO).

The CAP-log buffer is a circular buffer. When the buffer has filled up, eachnew CAP log report overwrites the oldest CAP log report in the buffer.When you display the CAP log reports using LOGUTIL or DLOG, you mayencounter one or more instances of the message, "Log not available oroverwritten due to log throttling." This message is displayed if a log reportin the buffer is so old that it no longer makes sense, or if a log report isincomplete because it has been overwritten by new data.

The CAP log buffer can hold up to three hours' worth of CAP log reports.

36 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 37: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The three hours need not be three consecutive hours. For example, if youdisable CAP logs for a length of time and then enable them again, the logreports in the buffer will be from non-consecutive hours.

CAP log reports survive warm and cold restarts.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatSwitch Reportid mmmdd hh:mm:ss ssdd Event type Log title

<min.>: OAvgDel<n>ms 95%OLim<n>ms PAvgDel<n>ms 95%PLim<n>

BAvgDel<n>ms 95%BLim<n>ms MAvgDel<n>ms 95%MLim<n>ms

Selected field descriptionsField Value Fixed or

VariableDescription

Switch TYPE="text" Variable Identifies the switch

Reportid CAP103 Variable The Reportid field displays the loggroup (CAP) and identification numberof the log report.

Event INFO Variable The Event Type displays the type ofevent identified in the log report.

Log CAPACITY_DETAIL Variable The Reportid field displays the loggroup and identification number of thelog report.

OAvgDel numeric Variable Weighted average waiting time on theCCB originating queue.

95%OLim numeric Variable This represents the 95% high watermark for the CCB originating queue.

PAvgDel numeric Variable Weighted average waiting time on theCCB progress queue.

95%PLim numeric Variable This represents the 95% high watermark for the CCB progress queue.

CAP103 37

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 38: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

BAvgDel numeric Variable Weighted average waiting time on theBackground (BKGCLASS) readyqueue.

95%BLim numeric Variable This represents the 95% high watermark for the Background ready queue.

MAvgDel numeric Variable Weighted average waiting time on theMaintenance (MAINTCLASS) readyqueue.

95%MLim numeric Variable This represents the 95% high watermark for the Maintenance readyqueue.

Active message exampleMTXJ10AF CAP103 AUG16 16:53:13 3400 INFO CAPACITY DETAIL

11: OAvgDe1 17ms 95%OLim 45ms PAvgDel 13ms 95%Plim 25ms

BAvgDel 12ms 95%BLim 25ms MAvgDel 11ms 95%MLim 25ms

12: OAvgDel 8ms 95%OLim 45ms PAvgDel 13ms 95%Plim 25ms

BAvgDel 12ms 95%BLim 25ms MAvgDel 11ms 95%MLim 25ms

13: OAvgDel 17ms 95%OLim 45ms PAvgDel 13ms 95%Plim 25ms

BAvgDel 12ms 95%BLim 25ms MAvgDel 13ms 95%MLim 25ms

14: OAvgDel 18ms 95%OLim 45ms PAvgDel 13ms 95%Plim 25ms

BAvgDel 12ms 95%BLim 25ms MAvgDel 12ms 95%MLim 25ms

15: OAvgDel 17ms 95%OLim 45ms PAvgDel 13ms 95%Plim 25ms

BAvgDel 12ms 95%BLim 25ms MAvgDel 12ms 95%MLim 25ms

Clear message examplen/a

Associated OM registers

LOST110LOST110 occurs when Call Processing gets a failure indication onattempting to output a message.

38 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 39: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

LOST110 in XA-Core

Log LOST110 is also generated in XA-Core when the messaging systemcannot send the message due to faults other than routing trouble. Thesefaults include:

• No buffer is available to enqueue the message for the outgoingmessage process.

• Failed to enqueue the message for the outgoing message process.

• The destination node has exceeded a congestion level.

• A user error is detected by the messaging system.

When the log is generated, a message is lost. The impact of losing amessage depends on the importance of the message. This log is used toalert the craftperson and helps in debugging the messaging problem.

A LOST log is generated whenever the I/O system or an application isunable to deliver a message. The discarded message is displayed in thelog. The impact of discarding a message depends on the importance of themessage. This cannot be determined by the I/O system as it has nounderstanding of message contents. A LOST log is used to alert thecraftsperson to a possible problem (for example, a hardware fault, or badconfiguration data).

Remedial actionNo immediate action is required as the problem may be transient. Shouldthis log occur more than three times in one minute, then retain the logs andcontact the next level of support.

AttributesAttribute Value

Severity Indeterminate

FormatLOST110 mmmdd hh:mm:ss ssdd EXC aaa

Message TID: Node=aaa, Terminal=aaa, Device=aaa

Time of Event: aaa

Message Dump:

aaa...

LOST110 39

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 40: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Application Data:

Buffer: aaa

Physical: aaa...

IOUI: aaa...

Reported by: aaa...

Selected field descriptionsField Value Fixed or

VariableDescription

EXC Constant Variable Identifies the log class (softwareexecution event).

MSG TOSSED Constant Variable Identifies the log error condition.

Node Decimal number Variable Identifies the peripheral internal nodenumber.

Terminal Decimal number Variable Identifies the peripheral internalterminal number.

Device Text Variable Identifies the peripheral external nodename.

Time of Event Decimal number Variable Indicates the time of day (formathour:minute:second:fraction) when theevent occurred.

Message Dump Hexadecimal number Variable Indicates the contents of themessage.

Buffer Text Variable Indicates the type of software buffer.

Physical Hexadecimal number Variable Identifies the routing header.

IOUI Hexadecimal number Variable Identifies the network header.

Reported by Text Variable Indicates five-level softwaretraceback.

Active message exampleXASKY07BA LOST110 SEP16 12:06:02 8800 EXC MSG TOSSED

Message TID: Node=32, Terminal=310, Device=DTC 20

Time of Event: 12:06:02.275

Message Dump:

710F B102 0100 5419 FD55 FC1A 860E FE12 0001 0015

40 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 41: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

2020 3F6B 840F 8507 0145 FDFD FDFD FDFD FDFD FDFD

FDFD FDFD FDFD FDFD FDFD FDFD FDFD FDFD

Application Data:

Buffer: DS30

Physical: FDFD FDFD

IOUI: 2600 FDFD 1020 FD36

Reported by: 01FF37E4=CPIOUI.JG07:FASTCP_DISPATCH+#0AB4

01FE6254=ISUPISUP.CY01:ISUP_ISU+#1194

0043E1A0=ISUPXPR.CS04:ISUP_XPR+#1040

01FC1D6C=ISUPHDLR.CL02:Q764_SEL+#028C

01FB9E2C=EDTKCPUI.BC01:EVENT_DR+#022C

Clear message examplen/a

Associated OM registers

LOST111LOST111 occurs when an incoming message cannot be delivered. Thespecific failure reason is displayed in the log.

A LOST log is generated whenever the I/O system or an application isunable to deliver a message. The discarded message is displayed in thelog. The impact of discarding a message depends on the importance of themessage. This cannot be determined by the I/O system as it has nounderstanding of message contents. A LOST log is used to alert thecraftsperson to a possible problem (for example, a hardware fault, or badconfiguration data).

Remedial actionNo immediate action is required as the problem may be transient. Shouldthis log occur more than three times in one minute, then retain the logs andcontact the next level of support.

LOST111 41

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 42: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Indeterminate

FormatLOST111 mmmdd hh:mm:ss ssdd EXC aaa

Message TID: Node=aaa, Terminal=aaa, Device=aaa, Bad IP=aaa

Time of Event: aaa

Message Dump:

aaa...

Application Data:

Buffer: aaa

Physical: aaa...

IOUI: aaa...

IH Error: Reason=aaa Data=aaa

Reported by: aaa...

Selected field descriptionsField Value Fixed or

VariableDescription

Terminal Decimal number Variable Identifies the peripheral internalterminal number.

Device Text Variable Identifies the peripheral external nodename.

Bad IP Decimal Integer Variable Indicates the source IP address. Thisis applicable only to Succession IP-based nodes.

Time of Event Decimal number Variable Indicates the time of day (formathour:minute:second:fraction) when theevent occurred.

Message Dump Hexadecimal number Variable Indicates the contents of themessage.

Buffer Text Variable Indicates the type of software buffer.

Physical Hexadecimal number Variable Identifies the routing header.

42 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 43: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

IOUI Hexadecimal number Variable Identifies the network header.

Reason Text Variable Indicates additional diagnosticinformation (character based).

Data Hexadecimal number Variable Indicates additional diagnosticinformation (numeric based).

Reported by Text Variable Indicates five-level softwaretraceback.

EXC Constant Variable Identifies the log class (softwareexecution event).

INPUT HANDLERERROR

Constant Variable Identifies the log error condition.

Node Decimal number Variable Identifies the peripheral internal nodenumber.

Active message exampleMERCURY_MSC LOST111 SEP16 08:12:38 5700 EXC INPUT HANDLERERROR

Message TID: Node=9, Terminal=2, Device=GWC 20, BadIP=47.111.6.231

Time of Event: 08:12:38.810

Message Dump:

01BE 0237 0A02 0000 4974 A9A0 0034 FFFF 0000 0000

0000 0000 0000 0000 0000 0000 0000 0000 0000 0000

0000 0000 0000 0000 0000 0000 60F9 00E2

Application Data:

Buffer: DS30

Physical: FFFF FFFF

IOUI: 4000 FFFF 60F9 00E2

IH Error: Reason=BAD_CPTLB_STATE Data=0003

Reported by: 0535EE38=XACPHAND.BG03:XCP_APPL+#1238

LOST111 43

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 44: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

00A6D020=XAIONET.BC01:INJECT_I+#0260

00497C30=IOCPBASE.BQ01:SENDIOMS+#0250

0613F808=GCMMSGXA.AH02:X_CGMMSG+#0268

019A5094=GCMMSGUI.BM01:GCMMSG_SEND_M+#0034

Clear message examplen/a

Associated OM registers

LOST116LOST116 occurs when an outgoing message is lost in the sending path.The faults that cause this are:

• XA-Core messaging path fails to get a BMS buffer to enqueue theapplication message.

• XA-Core messaging path fails to copy the application's message to theBMS buffer.

• XA-Core messaging path fails to send the application's message due tounavailable routing destination.

LOST116 occurs when an outgoing message encounters a failure. Thespecific failure reason is displayed in the log.

A LOST log is generated whenever the I/O system or an application isunable to deliver a message. The discarded message is displayed in thelog. The impact of discarding a message depends on the importance of themessage. This cannot be determined by the I/O system as it has nounderstanding of message contents. A LOST log is used to alert thecraftsperson to a possible problem (for example, a hardware fault, or badconfiguration data).

Remedial actionNo immediate action is required as the problem may be transient. Shouldthis log occur more than three times in one minute, collect the activeFootprint buffer for MSG class events and contact the next level of support.

AttributesAttribute Value

Severity Indeterminate

44 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 45: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatLOST116 mmmdd hh:mm:ss ssdd EXC aaa

Message TID: Node=aaa, Terminal=aaa, Device=aaa

Time of Event: aaa

Message Dump:

aaa...

Application Data:

Buffer: aaa

Physical: aaa...

IOUI: aaa...

Send Error: Reason=aaa Data=aaa

Reported by: aaa...

Selected field descriptionsField Value Fixed or

VariableDescription

EXC Constant Variable Identifies the log class (softwareexecution event).

SEND ERROR Constant Variable Identifies the log error condition.

Node Decimal number Variable Identifies the peripheral internal nodenumber.

Terminal Decimal number Variable Identifies the peripheral internalterminal number.

Device Text Variable Identifies the peripheral external nodename.

Time of Event Decimal number Variable Indicates the time of day (formathour:minute:second:fraction) when theevent occurred.

Message Dump Hexadecimal number Variable Indicates the contents of themessage.

Buffer Text Variable Indicates the type of software buffer.

Physical Hexadecimal number Variable Identifies the routing header.

IOUI Hexadecimal number Variable Identifies the network header.

LOST116 45

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 46: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Reason Text Variable Indicates additional diagnosticinformation (character based).

Data Hexadecimal number Variable Indicates additional diagnosticinformation (numeric based).

Reported by Text Variable Indicates five-level softwaretraceback.

Active message exampleMERCURY_MSC L0ST111 SEP16 07:49:48 1400 EXC SEND ERROR

Message TID: Node=275, Terminal=260, Device=DTC 103

Time of Event: 07:49:47.978

Message Dump:

ABCD 1CCC 640F 2000 1000 8007 9EOO 0020 8000 8412

0000 1E00 0002 0000 0200 5100 0000 FD00 FDFD FDFD

FDFD FDFD FDFD FDFD FDFD FDFD FDFD FDFD

Application Data:

Buffer: DS30

Physical: FDFD FDFD

IOUI: 2B00 FDFD 1113 FD04

Send Error: Reason=ROUTE_UNAVAILABLE Data=0000

Reported by: 0049CD84=IONETUI.CQ03:CMC_OUTPUT+#0144

01509170=PPMUI.EM02:DISPATCH_P+#01D0

02797110=ISUPA.ED04:ISUP_PHY+#0070

00CFE464=TPUI.EB01:DISPATCH+#0024

02792138=ISUPA.ED04:ISUP_UPD+#0118

Clear message examplen/a

46 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 47: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

LOST117LOST117 occurs when an outgoing message is discarded in the outgoingmessage path. The specific failure reason is displayed in the log.

A LOST log is generated whenever the I/O system or an application isunable to deliver a message. The discarded message is displayed in thelog. The impact of discarding a message depends on the importance of themessage. This cannot be determined by the I/O system as it has nounderstanding of message contents. A LOST log is used to alert thecraftsperson to a possible problem (for example, a hardware fault, or badconfiguration data).

Remedial actionNo immediate action is required as the problem may be transient. Shouldthis log occur more than three times in one minute, collect the activeFootprint buffer for MSG class events and contact the next level of support.

AttributesAttribute Value

Severity Indeterminate

FormatLOST117 mmmdd hh:mm:ss ssdd EXC aaa

Message TID: Node=aaa, Terminal=aaa, Device=aaa

Time of Event: aaa

Message Dump:

aaa...

Application Data:

Buffer: aaa

Physical: aaa...

IOUI: aaa...

Outgoing Error: Reason=aaa Data=aaa

Reported by: aaa...

LOST117 47

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 48: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

EXC Constant Variable Identifies the log class (softwareexecution event).

OUTGOING ERROR Constant Variable Identifies the log error condition.

Node Decimal number Variable Identifies the peripheral internal nodenumber.

Terminal Decimal number Variable Identifies the peripheral internalterminal number.

Device Text Variable Identifies the peripheral external nodename.

Time of Event Decimal number Variable Indicates the time of day (formathour:minute:second:fraction) when theevent occurred.

Message Dump Hexadecimal number Variable Indicates the contents of themessage.

Buffer Text Variable Indicates the type of software buffer.

Physical Hexadecimal number Variable Identifies the routing header.

IOUI Hexadecimal number Variable Identifies the network header.

Reason Text Variable Indicates additional diagnosticinformation (character based).

Data Hexadecimal number Variable Indicates additional diagnosticinformation (numeric based).

Reported by Text Variable Indicates five-level softwaretraceback.

Active message exampleMERCURY_MSC LOST117 NOV01 07:49:48 1400 EXC OUTGOING ERROR

Message TID: Node=275, Terminal=260, Device=DTC 103

Time of Event: 07:49:47.978

Message Dump:

ABCD 1CCC 640F 2000 1000 8007 9EOO 0020 8000 8412

0000 1E00 0002 0000 0200 5100 0000 FD00 FDFD FDFD

FDFD FDFD FDFD FDFD FDFD FDFD FDFD FDFD

Application Data:

48 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 49: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Buffer: DS30

Physical: FDFD FDFD

IOUI: 2B00 FDFD 1113 FD04

Outgoing Error: Reason=BAD_FIQS_RC Data=0000

Reported by: 024BF4CC=XAIOEH.AA02:HANDLE_M+#04BC

01FF0910=XAIOLINK.AV02:XA_OUTPUT_D+#037C

02797110=IOLINKUI.BJ03:PRIVATE_+#0070

00CFE464=XAIONET.AY03:XA_PRIVA+#0024

02792138=XATXMSG.AM03:MSG_TC_H+#0118

Clear message examplen/a

Associated OM registers

SOS701Log title: SNTP offset is greater than 500ms.

This log is generated if the Network Time Protocol (NTP) is the timingreference for the time-of-day clock, and if the time-of-day clock is morethan 500ms ahead of or behind the timing reference.

Office parameter SNTP_CLIENT in table OFCENG controls whether theNTP is used as a timing reference for the time-of-day clock. The NTP isused as the reference only in the German market.

An SOS701 log report indicates a TOD Critical alarm. The TOD alarms arevisible in the TOD field, at the following MAP level:

MAPCI;MTC;APPL;OAMAP.

To view this log, use the following commands, starting from the CI MAPlevel.

CI>LOGUTIL

LOGUTIL>OPEN SOS

SOS701 49

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 50: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionUse the SETTIMETONTP command to synchronize to the NTP timingreference. For instructions, see "How to check and adjust the XA-CoreTOD" in the Nortel XA-Core Fault and Performance Management(297-8991-510).

AttributesAttribute Value

Severity Critical

Formatn/a

Active message examplen/a

Clear message examplen/a

Associated OM registers

SOS702Log title: SDM has a problem servicing the NTP request.

This log is generated if the Network Time Protocol (NTP) is the timingreference for the time-of-day clock, and if there is an indication that theSuperNode Data Manager cannot respond to a query-time or set-timerequest.

Office parameter SNTP_CLIENT in table OFCENG controls whether theNTP is used as a timing reference for the time-of-day clock. The NTP isused as the reference only in the German market.

Any of the following can trigger this log:

• The SDM does not respond to a request for five minutes.

• The SDM does not provide the NTP reference time, thus indicating thatit has lost synchronization with the NTP timing reference.

• The SDM issues a series of invalid responses, and the number of suchresponses exceeds an internal threshold value. Round-trip delaysexceeding an internal limit are considered as invalid responses.

The reason text in the log indicates the trigger event.

50 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 51: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

An SOS702 log report indicates a TOD Major alarm. The TOD alarms arevisible in the TOD field, at the following MAP level:

MAPCI;MTC;APPL;OAMAP.

To view this log, use the following commands, starting from the CI MAPlevel.

CI>LOGUTIL

LOGUTIL>OPEN SOS

Remedial actionVerify the SDM connectivity with the computing module, and verify the NTPserver operation at the SDM.

AttributesAttribute Value

Severity Major

Formatn/a

Active message examplen/a

Clear message examplen/a

Associated OM registers

SOS703Log title: SNTP information log.

This log is generated if the Network Time Protocol (NTP) is the timingreference for the time-of-day clock, and if an event occurs that requires aninformation log.

Office parameter SNTP_CLIENT in table OFCENG controls whether theNTP is used as a timing reference for the time-of-day clock. The NTP isused as the reference only in the German market.

SOS703 51

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 52: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Any of the following can trigger this log:

• Successful execution of a query-time or set-time command.

• The offset between the time-of-day and the NTP timing reference is inthe range 300ms to 500ms.

• The time-of-day has been adjusted with a leap second.

The reason text in the log indicates the trigger event.

To view this log, use the following commands, starting from the CI MAPlevel.

CI>LOGUTIL

LOGUTIL>OPEN SOS

Remedial actionn/a

AttributesAttribute Value

Severity Indeterminate

Formatn/a

Active message examplen/a

Clear message examplen/a

Associated OM registers

XAC300The system generates the Low Shared Memory (LowSM) log report whenthere is a loss of service of one or more XA-Core shared memory (SM)circuit packs (CP).

The LowSM log report describes the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the LowSM Condition Cleared log (XAC600)report.

52 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 53: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The LowSM log report generates a Card List when the system detects afault on more than one CP or packlet. The Card List displays other CPsand packlets that operating company personnel need to check as possiblesources of the fault identified in the log report.

A LowSM log report indicates one of two alarm levels:LowSM Major alarm:Shared memory redundancy is lost. XA-Core shared memory is running inSimplex.LowSM Minor alarm: A shared memory CP is out-of-service(OOS). XA-Core shared memory remains duplicated, but spare memory isnot available.

Event type: Fault (FLT)

Remedial actionIf the Shared Memory (SM) circuit pack (CP) state is ManB, return the SMCP to service.

If the SM CP state is InSv, check other SM CPs for faults.

If the system is in split mode, take no action. The SM CP returns-to-servicewhen the system exits split mode.

If the SM CP state is not ManB or InSv, and the system is not in splitmode, check for a card list in the log report. The card list displays otherCPs and packlets that can contain a fault.

AttributesAttribute Value

Severity • Major

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC /Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

XAC300 53

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 54: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Severity Two asterisks (**), orone asterisk (*)

Variable Displays the severity of the associatedalarm.

Two asterisks (**) indicate a majoralarm condition. Shared memoryredundancy is lost. XA-Core sharedmemory is running in simplex.

One asterisk (*) indicates a minoralarm condition. A shared memory CPis out-of-service (OOS). XA-Coreshared memory remains duplicated,but spare memory is not available.

Reportid XAC300 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

54 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 55: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

XAC300 55

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 56: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

56 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 57: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Active message example** XAC300 JAN01 17:52:34 0011 FLT LowSM (Low Shared Memory)

IMPACT: Shared Memory redundancy is lost. Running inSimplex.

DESCRIPTION: State has changed from INSV to SYSB by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

SM SysB HOST 01 A00 DPCC:00 01 17F NTLX14CA/nnnnnnnnnn

REASON: XA-Core fault.

ACTION: Check the other card(s) for possible source offault.

XAC300 57

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 58: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FAULT RECORD ID: 12345678

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

70% SM SysB 01 A00 DPCC:00 01/07F NTLX14CA/nnnnnnnnn

30% IOP IsTb 01 A00 DPCC:00 01/03F NTLX03BA/nnnnnnnnn

Clear message examplen/a

Associated OM registers

• XASMCRIU; XARSMPXU; XAMSMPXU; XASSMPXU; XASM

XAC302The system generates the Low Processor Element (LowPE) log reportwhen there is a loss of service of one or more XA-Core processorelements (PE).

The LowPE log report describes the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the LowPE Condition Cleared log (XAC602)report.

The LowPE log report generates a Card List when the system detects afault on more than one CP or packlet. The Card List displays other CPsand packlets that operating company personnel need to check as possiblesources of the fault identified in the log report.

In CSP15, a LowPE log report indicates one of two alarm levels:LowPECritical Alarm: The amount of PE capacity that has been lost is so largethat all redundant capacity is absent and the XA-Core cannot meet therequired processing capacity. In CSP15 this means that more than one PECP is out of service.LowPE Major Alarm: The amount of PE capacity thathas been lost is so large that all redundant capacity is absent. In CSP15this means that one PE CP is out of service.

A LowPE minor alarm is not possible in CSP15. Such an alarm indicatesthat some but not all redundant capacity has been lost. All the PEconfigurations supported in CSP15 are "+1" configurations. A minor alarmcan occur only if the configuration is "+2" or greater.

Event type: Fault (FLT)

58 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 59: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Reason

The following message has been added in CSP15. The reason field candisplay the message "Maximum allowed number of PE cards already in-service," to explain the failure of an RTS command to put a PE CP intoservice.

Remedial actionIf the processor element (PE) circuit pack (CP) state is ManB, return-to-service (RTS) the PE circuit pack.

If the PE CP state is InSv, check other PE CPs for faults.

If the XA-Core system is in split mode, take no action. The PE CP willreturn- to-service when the system exits split mode.

If the PE CP state is not ManB or InSv, and the system is not in split mode,check for a card list in the log. The card list displays other CPs andpacklets that can contain a fault.

AttributesAttribute Value

Severity • Critical

• Major

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

XAC302 59

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 60: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

..............

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Severity Three asterisks (***)or two asterisks (**)

Variable Displays the severity of the associatedalarm. Three asterisks indicate acritical LowPE alarm condition. Theamount of PE capacity that has beenlost is so large that all redundantcapacity is absent and the XA-Corecannot meet the required processingcapacity. In CSP15 this means thatmore than one PE CP is out ofservice. Two asterisks indicate aLowPE major alarm condition. All theredundant capacity has been lost. InCSP15 this means that one PE CP isout of service.

Reportid XAC302 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

60 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 61: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

XAC302 61

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 62: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

62 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 63: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Active message example** XAC302 OCT22 15:22:28 9700 FLT LowPE (Low ProcessorElement)

IMPACT: PE count reduced to minimum performancerequirements.

DESCRIPTION: State has changed from INSV to SYSB by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

PE InSv HOST 01 A00 DPCC:00 01 16F NTLX02BA/nnnnnnnnnn

REASON: XA-Core fault.

ACTION: Contact next level of support.

XAC302 63

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 64: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FAULT RECORD ID: 12345678

** XAC302 OCT26 17:52:34 9200 FLT LowPE (Low ProcessorElement)

IMPACT: PE count reduced to minimum performancerequirements.

DESCRIPTION: State has changed from INSV to SYSB by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

PE InSv HOST 01 A00 DPCC:00 01 16F NTLX02BA/nnnnnnnnnn

REASON: XA-Core fault.

ACTION: Contact the next level of support.

FAULT RECORD ID: 12345678

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

70% PE SysB 01 A00 DPCC:00 01 16F NTLX02AA/nnnnnnnnn

30% IOP IsTb 01 A00 DPCC:00 01/12F NTLX03BA/nnnnnnnnn

Clear message examplen/a

Associated OM registers

• XARXPE; XAPECRIU; XAPEMAJU; XAPE

XAC303The system generates the Message Switch Communication (MScomm) logreport when any of the following conditions occur:

There is a loss of communication between the XA-Core and the messageswitch (MS).

There is a loss of CMIC link redundancy.

There is a partial loss CMIC link redundancy.

64 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 65: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The MScomm log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the MScomm Alarm Cleared log (XAC603)report.

The MScomm log report generates a Card List when the system detects afault on more than one CP or packlet. The Card List displays other CPsand packlets that operating company personnel need to check as possiblesources of the fault identified in the log report.

A MScomm log indicates one of three alarm levels:

• MScomm Critical alarm: There is no communication between the XA-Core and the MS. The CMIC hardware in the XA-Core (HCMIC circuitpacks or OC-3 two port interface packlets), the physical links, or theMS cannot provide communication service.

• MScomm Major alarm: There is a loss of CMIC link redundancybetween the XA-Core and the MS.

• MScomm Minor alarm: There is a partial loss of CMIC link redundancybetween the XA-Core and the MS.

Event type: Fault (FLT)

Remedial actionIf the CMIC hardware in the XA-Core shelf (HCMIC circuit pack or OC-3two port interface packlet) is ManB, attempt to return the it to service.Replace the circuit pack or packlet if faulty.

If the CMIC packlet state is CBsy because an IOP CP is out-of-service,ensure the identified input/output processor (IOP) circuit pack is in-service.

If the CMIC hardware in the XA-Core shelf (HCMIC circuit pack or OC-3two port interface packlet) is SysB, attempt to return it to service. Replacethe circuit pack or packlet if faulty.

If the CMIC hardware in the XA-Core shelf (HCMIC circuit pack or OC-3two port interface packlet) is in-service (InSv) or in-service-trouble (IsTb),check integrity of link(s), and the state of MS ports.

If the XA-Core system is in split mode, take no action. The CMIC hardwareand links will return-to-service when the system exits split mode.

If the state of the CMIC hardware in the XA-Core shelf (HCMIC circuit packor OC-3 two port interface packlet) is unknown and a state change hasoccurred on the CMIC hardware, link, or MS port, ensure CMIC hardwareand MS Port are in-service. Check the integrity of the links.

XAC303 65

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 66: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Critical

• Major

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. If

66 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 67: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

the device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Severity Three asterisks (***)or two asterisks (**) orone asterisk (*)

Variable Displays the severity of the associatedalarm. Three asterisks indicate acritical alarm condition. There is no

XAC303 67

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 68: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

communication between the XA-Coreand the Message Switch (MS). Twoasterisks indicate a major alarmcondition. There is a loss of OC-3 two-port interface packlet (CMIC packlet)link redundancy between the XA-Coreand the MS. One asterisk indicates aminor alarm condition. There is apartial loss of OC-3 two-port interfacepacklet link redundancy between theXA-Core and the MS.

Reportid XAC303 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

68 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 69: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the CMIC links are supported byOC-3 two port interface packlets, thisis a character identifying the packletposition (upper or lower). Possiblevalues are U and L. If the links aresupported by HCMIC circuit packs, thefield is blank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only if

XAC303 69

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 70: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

the Class of the resource involved inthe state change is PORT, LINK, orTOD.

Active message example** XAC303 OCT27 15:22:28 1800 FLT MScomm {Message SwitchCommunication)

IMPACT: 1 of 4 CMIC Links on XA-Core are in-service.

DESCRIPTION: State has changed from INSV to SYSB by SYSTEMaction.

LINK: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

CMICInSv HOST 01 A00 DPCC:00 00 04R0 NTLX05AA/nnnnnnnnnn

REASON: XA-Core fault.

ACTION: Check integrity of link(s), and state of MS ports.

FAULT RECORD ID: 12345678

Clear message examplen/a

Associated OM registers

• XARXIO; XAIOP; XCMICLNK; XCMICPRT; XCMIC

XAC304The system uses time-of-day (TOD) clocks to generate billing informationand produce log reports. The TODs are in the CMIC hardware in the XA-Core shelf, that is, in the HCMIC circuit packs or in the OC-3 two portinterface packlets. Each HCMIC circuit pack has two TODs. Each OC-3two-port interface packlet (CMIC packlet) has one TOD.

The system generates the Time-of-Day (TOD) log report when any of thefollowing conditions occur:

There is a loss in service of TOD clocks on the message switch (MS).

There is a loss in service of TOD clocks on the XA-Core.

70 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 71: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

There is a loss of redundancy of TOD clocks on the XA-Core.

The TOD log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the TOD Alarm Cleared log (XAC604) report.

The TOD log report generates a Card List when the system detects a faulton more than one CP or packlet. The Card List displays other CPs andpacklets that operating company personnel need to check as possiblesources of the fault identified in the log report.

A TOD log indicates one of three alarm levels:

TOD critical alarm

TOD major alarm

TOD minor alarm

For explanations of the meanings of the TOD alarms, see the introductorysections of the procedures for clearing those alarms. The procedures arein the Nortel XA-Core Fault and Performance Management(297-8991-510), in the chapter titled "Understanding the alarm system".

Event type: Fault (FLT)

Remedial actionIf a CMIC packlet state is CBsy, return the input/output processor (IOP)circuit pack (CP) to service, or replace the IOP CP if faulty.

If the state of an item of CMIC hardware on the XA-Core shelf (an HCMICcircuit pack or a CMIC packlet) is ManB or SysB, return the item ofhardware to service, or replace it if faulty.

If the state of the CMIC hardware on the XA-Core shelf (HCMIC circuitpacks or CMIC packlets) is InSv or IsTb, and the XA-Core TOD state isCBsy, ensure that the links to the MS are in-service.

If the state of the CMIC hardware on the XA-Core shelf (HCMIC circuitpacks or CMIC packlets) is InSv or IsTb, and the XA-Core TOD state isInSv, or IsTb, ensure that the MS TODs are InSv.

If the state of the CMIC hardware on the XA-Core shelf (HCMIC circuitpacks or CMIC packlets) is InSv, or IsTb, and the XA-Core TOD state isManB, check the MS TOD(s) and the XA-Core TOD and link.

XAC304 71

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 72: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

If the state of the CMIC hardware on the XA-Core shelf (HCMIC circuitpacks or CMIC packlets) is InSv, or IsTb, and the XA-Core TOD state isSysB or not available, check the MS TOD (s) and the XA-Core TOD andlink integrity to isolate the problem.

If the state of the CMIC hardware on the XA-Core shelf (HCMIC circuitpacks or CMIC packlets) is unknown, and the XA-Core TOD state is CBsy,ensure that the CMIC hardware is InSv. If the CMIC hardware is a CMICpacklet, ensure that the IOP circuit pack is also InSv. Also ensure that thelinks to the MS are InSv.

If the state of the CMIC hardware on the XA-Core shelf (HCMIC circuitpacks or CMIC packlets) is unknown, and the XA-Core TOD state is InSvor IsTb, ensure that the MS TODs are InSv.

If state of the CMIC hardware on the XA-Core shelf (HCMIC circuit packsor CMIC packlets) is unknown, and the XA-Core TOD state is ManB,ensure that the MS TODs are InSv.

If the state of the CMIC hardware on the XA-Core shelf (HCMIC circuitpacks or CMIC packlets) is unknown, and the XA-Core TOD state is SysBor unknown, check the MS TOD (s), and the XA-Core TOD and linkintegrity to isolate the problem.

AttributesAttribute Value

Severity • Critical

• Major

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

72 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 73: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Severity Three asterisks (***),two asterisks (**), orone asterisk (*)

Variable Displays the severity of the associatedalarm.

Three asterisks (***) indicate a criticalalarm condition. Four out of four TODclocks on the message switch (MS)are out-of-service (OOS), or two out oftwo TODs on the XA-Core are OOS.

Two asterisks (**) indicate a majoralarm condition. There is a loss ofredundancy of TOD clocks on the XA-Core. One TOD clock on the XA-Coreis OOS.

One asterisk (*) indicates a minoralarm condition. A TOD clock on theMS is OOS.

Reportid XAC304 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

XAC304 73

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 74: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

74 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 75: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the CMIC links are supported byOC-3 two port interface packlets, thisis a character identifying the packletposition (upper or lower). Possiblevalues are U and L. If the links aresupported by HCMIC circuit packs, thefield is blank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

XAC304 75

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 76: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Active message example** XAC304 MAR01 15:22:28 6800 FLT TOD (Time of Day Clock)

IMPACT: XAC TOD can receive clock update from 1 out of 2 MSTODS.

DESCRIPTION: State has changed from INSV to SYSB by SYSTEMaction.

TOD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

CMICInSv HOST 01 A00 DPCC:00 00 04RL0 NTLX05AA/nnnnnnnnnn

76 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 77: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

REASON: At least one MS TOD is not providing clock update.

ACTION: Ensure that MS TODs are InSv.

FAULT RECORD ID: 12345678

Clear message examplen/a

Associated OM registers

• XCMICLNK; XCMICPRT; XCMIC; XAIOP

XAC305The system generates the Reset Terminal Interface (RTIF) log report whenthere is a loss in service of RTIF local or remote ports.

The RTIF log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the RTIF Alarm Cleared log (XAC605) report.

The RTIF log report generates a Card List when the system detects a faulton more than one CP or packlet. The Card List displays other CPs andpacklets that operating company personnel need to check as possiblesources of the fault identified in the log report.

An RTIF log report indicates one of three alarm levels:

RTIF critical alarm

RTIF major alarm

RTIF minor alarm

For explanations of the meanings of the RTIF alarms, see the introductorysections of the procedures for clearing those alarms. The procedures arein the Nortel XA-Core Fault and Performance Management(297-8991-510), in the chapter titled "Understanding the alarm system".

Event type: Fault (FLT)

Remedial actionIf the hardware supporting the RTIF link (an HCMIC circuit pack or an RTIFpacklet) is in the ManB state, attempt to return it to service. Replace iffaulty.

XAC305 77

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 78: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

If the RTIF packlet state is CBsy, ensure the input/output processor (IOP)circuit pack (CP) is in-service.

If the hardware supporting the RTIF link (an HCMIC circuit pack or an RTIFpacklet) is in the SysB state, attempt to return the it to service. Replace iffaulty.

If the hardware supporting the RTIF link (an HCMIC circuit pack or an RTIFpacklet) is in the InSv state or the IsTb state, test any out-of-service portsand check the integrity of cables and terminal connections. Replace thecircuit pack or packlet, or the cables, if faulty.

If the XA-Core system is in split mode, take no action. The RTIF hardwarewill return-to-service when split mode is exited.

If the state of the hardware supporting the RTIF link (an HCMIC circuitpack or an RTIF packlet) is unknown, and the RTIF local or remote portstate is ManB, attempt to return the ManB port to service.

If the state of the hardware supporting the RTIF link (an HCMIC circuitpack or an RTIF packlet) is unknown, and the RTIF local or remote portstate is SysB, replace the circuit pack or packlet if faulty.

If the state of the hardware supporting the RTIF link (an HCMIC circuitpack or an RTIF packlet) is unknown, and the RTIF local or remote portstate is CBsy,

if the RTIF hardware is an RTIF packlet, ensure that the packlet and IOPCP are InSv

if the RTIF hardware is an HCMIC CP, ensure that the CP is InSv

If the state of the hardware supporting the RTIF link (an HCMIC circuitpack or an RTIF packlet) is unknown,, and the RTIF local and remote stateis unknown,

if the RTIF hardware is an RTIF packlet, ensure that the RTIF packlet andports are in-service.

if the RTIF hardware is an HCMIC CP, ensure that the CP and its RTIFports are in-service

78 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 79: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Critical

• Major

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Severity Three asterisks (***),two asterisks (**), orone asterisk (*)

Variable Displays the severity of the associatedalarm.

XAC305 79

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 80: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Three asterisks (***) indicate a criticalalarm. Both RTIF local or remote portsare out-of-service (OOS).

Two asterisks (**) indicates a majoralarm. One RTIF local port is OOS orBoth RTIF remote ports are OOS (andoperating company personnel haveset office parameter REMTERMEQPto true).

One asterisk (*) indicates a minoralarm. One RTIF remote port is OOS(and operating company personnelhave set office parameterREMTERMEQP to true).

Reportid XAC305 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,

80 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 81: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the RTIF links are supported byRTIF packlets, this is a characteridentifying the packlet position (upper

XAC305 81

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 82: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

or lower). Possible values are U andL. If the links are supported y HCMICcircuit packs, the field is blank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

82 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 83: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Active message example*** XAC305 OCT27 15:22:28 1800 RTIF (Reset TerminalInterface)

IMPACT: n of n RTIF remote ports required on XA-Core are in-service.

DESCRIPTION: State has changed from INSV to SYSB by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slot/Pk EqPEC/Serial

RTIFCBsy HOST 01 A00 DPCC:00 01 15R L NTLX05AA/nnnnnnnnnn

REASON: RTIF packlet is CBsy due to out of service IOP.

ACTION: Ensure IOP card is in-service.

FAULT RECORD ID: 12345678

Clear message examplen/a

Associated OM registers

• XAIOP; XRTIF

XAC306The system generates the Disk log report when a Disk packlet is out-of-service (OOS).

The Disk log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the Disk Alarm Cleared log (XAC606) report.

XAC306 83

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 84: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The Disk log report generates a Card List when the system detects a faulton more than one CP or packlet. The Card List displays other CPs andpacklets that operating company personnel need to check as possiblesources of the fault identified in the log report.

A Disk log report indicates a Disk Minor alarm condition. This alarmcondition means that at least one Disk packlet is OOS.

Event type: Fault (FLT)

Remedial actionIf the Disk packlet state is ManB, return the Disk packlet to service.

If the Disk packlet state is CBsy, return the input/output processor (IOP)circuit pack (CP) to service.

If the XA-Core system is in split mode, take no action. The Disk packletreturns-to-service (RTS) when the XA-Core system exits split mode.

AttributesAttribute Value

Severity Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

84 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 85: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Severity One asterisk (*) Variable Displays the severity of the associatedalarm. One asterisk (*) indicates aminor alarm condition. At least oneDisk packlet is out-of-service (OOS).

Reportid XAC306 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,

XAC306 85

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 86: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

86 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 87: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,

XAC306 87

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 88: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Active message example* XAC306 JAN01 15:22:28 0011 FLT Disk

IMPACT: At least one Disk packlet is out of service.

DESCRIPTION: State has changed from INSV to CBSY by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

DISKCBsy HOST 01 A00 DPCC:00 01 02F L NTLX06AA/nnnnnnnnnn

REASON: Disk packlet is CBsy due to out of service IOP.

ACTION: Return IOP card to service.

FAULT RECORD ID: 12345678

Clear message examplen/a

Associated OM registers

• XADISK; XAIOP

XAC307The system generates the Tape log report when a Tape packlet is out-of-service (OOS).

The Tape log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the Tape Alarm Cleared log (XAC607) report.

The Tape log report generates a Card List when the system detects a faulton more than one CP or packlet. The Card List displays other CPs andpacklets that operating company personnel need to check as possiblesources of the fault identified in the log report.

88 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 89: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

A Tape log report indicates a Tape Minor alarm condition. This alarmcondition means at least one Tape packlet is OOS.

Event type: Fault (FLT)

Remedial actionIf the Tape packlet state is ManB, return the Tape packlet to service.

If the Tape packlet state is CBsy, return the input/output processor (IOP)CP to service.

If the XA-Core system is in split mode, take no action. The Tape packletreturns-to-service (RTS) when the XA-Core system exits Split mode.

AttributesAttribute Value

Severity Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

XAC307 89

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 90: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,

90 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 91: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

One asterisk (*) indicates a minoralarm condition. At least one Tapepacklet is out-of-service (OOS).

Reportid XAC307 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

XAC307 91

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 92: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only if

92 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 93: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

the Class of the resource involved inthe state change is PORT, LINK, orTOD.

Active message example* XAC307 MAR17 15:22:28 0011 FLT Tape

IMPACT: At least one tape packlet is out of service.

DESCRIPTION: State has changed from INSV to CBSY by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

TapeCBsy HOST 01 A00 DPCC:00 00 02F U NTLX07AA/nnnnnnnnnn

REASON: Tape packlet is CBsy due to out of service IOP.

ACTION: Return IOP card to service.

FAULT RECORD ID: 12345678

Clear message examplen/a

Associated OM registers

• XAIOP; XATAPE

XAC308The system generates the Image Test Report log report when the XA-Coreimage test executes. The XA-Core image test checks for correct softwarefunction and image restart capability.

The Image Test Report log report indicates the recommended action thatoperating company personnel can follow to correct the condition identifiedin the log. When the condition clears, the system generates the ImageAlarm Cleared log (XAC608) report.

An Image Test Report log indicates an Image Critical alarm condition. Thisalarm condition indicates that an XA-Core Image is bad.

Event type: Fault (FLT)

XAC308 93

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 94: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionIf the image test indicates Image may be Ok, the image may not berestartable. Contact Emergency Personnel.

If the image test indicates Image Bad, the image is not restartable. Do nottry an active restart. Contact Emergency Personnel.

If the image test indicates Image Test Aborted, or Image Test Not Run,take no action.

AttributesAttribute Value

Severity • Critical

• Major

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

INITIATOR:<Manual/System/REx>

RESTART TYPE:<Warm/Cold/Reload>

RESULT:<Image Maybe Okay/Image Bad/Image Test Aborted/ImageTest Not Run

SUBTEST/PROCESS CHECK: FAILED NOT-RUN

RTS Matecom

Sending Data to Inactive Side

Receiving Data from Inactive Side

Inactive Timeout

Login for Disconnected User

Response from Command Interface

Critical Process Verification

Overall Process

Login Process

94 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 95: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

HDRCON Process

NHDRCON Process

CALLP Process

Program Store Check

Data Store Check

Allocating DS Temp

Allocating DS Prot

Allocating DS Perm

Allocating PS Temp

Allocating PS Prot

Deallocating DS Temp

Deallocating DS Prot

Deallocating DS Perm

Deallocating PS Temp

Deallocating PS Prot

Trap Rate Check

IMPACT:<Impact statement>

ACTION:<Action Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC308 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

XAC308 95

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 96: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

INITIATOR Manual, System, orREx

Variable The INITIATOR field identifies themethod used to start an image test.

RESTART TYPE Warm, Cold, orReload

Variable The RESTART TYPE field indicatesthe type of restart used to take animage test

RESULT Image Maybe Okay,Image Bad, ImageTest Aborted, orImage Test Not Run

Variable The RESULT field indicates the resultof the XA-Core image test.

SUBTEST/PROCESS CHECK

Text string Variable The SUBTEST/PROCESS CHECKfield describes specific subtests orprocess checks that failed or were notrun during an XA-Core image test.

FAILED "X" Variable An "X" indicates that the subtest orprocess check failed during an imagetest. Log report XAC308 only displaysthe subtests or process checks thatfailed or were not run during an imagetest.

NOT-RUN "X" Variable An "X" indicates that the subtest andprocess check was not run during animage test. Log report XAC308 onlydisplays those subtests or processchecks that failed or were not runduring an image test.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core.

ACTION Text string Variable The Action field recommends theaction that operating companypersonnel can take to correct theproblem identified in the log report.

Severity Two asterisks (**), orone asterisk (*)

Variable Displays the severity of the associatedalarm.

Two asterisks (**) indicates a majoralarm condition. An XA-Core imagetest detected that an image is Bad.

One asterisk (*) indicates a minoralarm condition. An XA-Core imagetest detected that an image maybeokay, an image test aborted, or animage test was not run.

96 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 97: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message example** XAC308 MAY07 10:11:09 9000 FLT Image Test Report

INITIATOR: System

RESTART TYPE: Warm

RESULT: Image Bad

SUBTEST/PROCESS CHECK: FAILED NOT-RUN

RTS Matecom X

Sending Data to Inactive Side X

Receiving Data from Inactive Side X

Inactive Timeout X

Login for Disconnected User x

Response from Command Interface X

Critical Process Verification

Overall Process X

Login Process X

HDRCON Process X

NHDRCON Process X

CALLP Process X

Program Store Check X

Data Store Check X

Allocating DS Temp X

Allocating DS Prot X

Allocating DS Perm X

Allocating PS Temp X

Allocating PS Prot X

XAC308 97

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 98: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Deallocating DS Temp X

Deallocating DS Prot X

Deallocating DS Perm X

Deallocating PS Temp X

Deallocating PS Prot X

Trap Rate Check X

IMPACT: Image is not restartable

ACTION: Do not attempt an active restart!

Contact Emergency Personnel.

Clear message examplen/a

Associated OM registers

XAC309The system generates the ATM multinode data interface (AMDI) log reportwhen there is a loss of communication between the XA-Core and anySuccession multi gateway (SMG) peripheral. The log also occurs whenthere is a loss of AMDI packlet link redundancy.

The AMDI log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the AMDI cleared (XAC609) log report.

The AMDI log generates a card list when the system detects a fault onmore than one packlet. The card list displays other packlets that operatingcompany personnel need to check as possible sources of the faultidentified in the log report.

An AMDI log indicates one of two alarm levels

AMDI Critical Alarm: There is no communication between the XA-Core andat least one SMG peripheral.

AMDI Major Alarm: There is a loss of AMDI packlet link redundancybetween the XA-Core and SMG peripherals.

98 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 99: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Event type: Fault (FLT)

Remedial actionIf the state of the AMDI hardware (HIOP circuit pack or AMDI packlet) isManB, attempt to return it to service. Replace if faulty.

If the AMDI packlet state is Cbsy because an Input/Output Processor (IOP)circuit pack (CP) is out-of-service, ensure the identified IOP circuit is in-service.

If the state of the AMDI hardware (HIOP circuit pack or AMDI packlet) isSysB, attempt to return it to service. Replace if faulty.

If the state of the AMDI hardware (HIOP circuit pack or AMDI packlet) isunknown and a state change has occurred on an AMDI packlet, port, orlink, ensure that AMDI hardware is InSv. Check the integrity of the AMDIlinks.

If the AMDI link state is ManB, attempt to return to service the AMDI link.

If the AMDI link state is InSv, check the integrity of the link.

If the AMDI link state is SysB, contact next level of support if problempersists.

If the XA-Core system is in split mode, take no action. The AMDI hardwareand links will return to service when the system exits split mode.

If the AMDI link state is unknown and a state change has occurred on anAMDI link, ensure AMDI links are InSv.

AttributesAttribute Value

Severity • Critical

• Major

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

XAC309 99

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 100: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Severity Three asterisks (***)Two asterisks (**)

Variable Displays the severity of the associatedalarm.

Three asterisks (***) indicate a criticalalarm condition. There is nocommunication between the XA-Coreand at least one SMG peripheral.

Two asterisks (**) indicate a majoralarm condition. There is a loss ofAMDI packlet link redundancybetween the XA-Core and the SMGperipherals.

Reportid XAC309 Variable The reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

100 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 101: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

XAC309 101

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 102: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the AMDI links are supported by anAMDI packlet, this is a characteridentifying the packlet position (upperor lower). Possible values are U andL. If the AMDI links are supported byan HIOP circuit pack, the field isblank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

102 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 103: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Active message example** XAC309 OCT29 15:22:28 1199 FLT AMDI (ATM Multinode DataInterface)

IMPACT: Group redundancy changed.

DESCRIPTION: State has changed from INSV to MANB by MANUALaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

AMDIManB HOST 00 A00 DPCC:00 00 14R L NTLX05BA/nnnnnnnnnn

XAC309 103

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 104: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

REASON: AMDI link(S) are out of service due to manuallybusied packlet.

ACTION: Attempt to RTS AMDI links.

FAULT RECORD ID: 12345678

Clear message examplen/a

Associated OM registers

XAC310The Card Manual Busy log indicates that the craftsperson has manuallybusied a card, packlet, port, or link that was already in an out-of-servicestate.

Event type: Manual Busy (MBSY).

Remedial actionn/a

AttributesAttribute Value

Severity Indeterminate

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC310 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type MBSY Variable The Event Type field displays the typeof event identified in the log report.

104 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 105: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, and LINK. (TOD isnot a possible value because it is notpossible to busy a TOD device.)

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

XAC310 105

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 106: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the component that was busied is apacklet or a device on a packlet, thisis a character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT or LINK.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC310 JUN12 11:01:09 2400 MANB ManB (Card Manual Busy)

106 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 107: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DESCRIPTION: State has changed from CBSY to MBSY by MANUALaction

LINK: Type State Site FL Row Bay Shf/Slt/Pk/Lk EqPEC/Serial

ETHR MBSY HOST 01 A00 DPCC:00 00 05R U 0 NTLX09AA/nnnnnnnn

Clear message examplen/a

Associated OM registers

XAC312The system generates the input/output processor (IOP) log report when aninput/output processor (IOP) circuit pack or a high performance input/output processor (HIOP) circuit pack or a high performance CMIC (HCMIC)circuit pack is out-of-service (OOS).

The IOP log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the IOP Cleared log (XAC612) report.

The IOP log generates a Card List when the system detects a fault onmore than one CP or packlet. The Card List displays other CPs andpacklets that operating company personnel need to check as possiblesources of the fault identified in the log report.

A IOP log indicates an IOPflt Minor alarm condition. This alarm conditionmeans that at least one IOP or HIOP or HCMIC CP is OOS.

Event type: Fault (FLT)

Remedial actionIf the IOP or HIOP or HCMIC CP state is ManB, return the CP to service.

If the IOP or HIOP or HCMIC CP state is InSv, check other CPs for thesource of the fault.

AttributesAttribute Value

Severity Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

XAC312 107

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 108: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

108 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 109: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

XAC312 109

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 110: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

One asterisk (*) indicates a minoralarm condition. At least one IOP CPis out-of-service (OOS).

Reportid XAC312 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

110 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 111: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Active message example** XAC312 OCT30 15:22:28 0011 FLT IOP (Input OutputProcessor)

IMPACT: At least one IOP card is out of service.

DESCRIPTION: State has changed from INSV to MANB by MANUALaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

IOP ManB HOST 01 A00 DPCC:00 00 15R NTLX03BA/nnnnnnnnnn

REASON: IOP card has been manually busied.

ACTION: RTS IOP card.

XAC312 111

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 112: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FAULT RECORD ID: 12345678

Clear message examplen/a

Associated OM registers

• XAIOP;

XAC320The system generates the SysBTh Alarm Raised log report when aSysBTh alarm is raised and the severity of the alarm has changed. Thepossible scenarios are as follows.

The system raises a SysBTh minor alarm, and previously there were noSysBTh alarms.

The system increases the severity of a SysBTh alarm from minor to major.

The system decreases the severity of a SysBTh alarm from major to minor.

At any time when a SysBTh alarm is raised, that alarm represents thehighest level of SysBTh activity in the system. For example, if a PE circuitpack goes through enough system-busy transitions to justify the raising ofa minor alarm, but an IOP circuit pack goes through enough transitions tojustify the raising of a major alarm, the SysBTh major alarm will be raised.

The system monitors the SysB transitions for many components. (Themonitored components are listed later in this section). It maintains separatecounts for each instance of each monitored component.

The monitored components are separated into groups.

The following list shows the groups and the monitored components.

The PE group includes PE circuit packs.

The SM group includes SM circuit packs.

The IO link (IOlk) group includes all IO links.

The IO hardware (IOhw) group includes

IOP, HIOP, and HCMIC circuit packs

all packlets: disk, tape, CMIC, RTIF, Ethernet, and AMDI

112 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 113: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

sections of HIOP circuit packs that are supporting ETHR and AMDIconnections

sections of HCMIC circuit packs that are supporting CMIC, RTIF, andETHR connections

time-of-day (TOD) devices

ports

For each instance of each monitored component, the system counts theSysB transitions that occur during the current six-hour interval. It alsomaintains records of the numbers of transitions that occurred during theseven preceding six-hour intervals. For each component, the system sumsthe totals from the seven preceding intervals and the total from the currentinterval, producing the 48-hour total, which is the number of SysBtransitions occurring over the last 42 to 48 hours.

For each component group, there are minor and major SysB-transitionthreshold values. The thresholds apply to each component in thecomponent group. To obtain a list of the major and minor thresholds thatapply to the component groups, use the CNTRS QUERY command. Thesystem displays the threshold values as part of its response to the CNTRSQUERY command. For detailed information on the display of thresholdvalues, see the description of the QUERY parameter of the CNTRScommand in the XAC MAP level. The description is found in the Nortel XA-Core Reference Manual (297-8991-810), in the chapter that describesMAP levels and user interfaces.

For each monitored component, the system compares the component's 48-hour transition total to the minor and major SysB transition thresholds forthe group. If the 48-hour SysB transition total equals or exceeds the minorSysB transition threshold, and if the SysBTh minor alarm or SysBTh majoralarm is not already raised, the system raises the SysBTh minor alarm(unless the alarm has been disabled). If the 48-hour SysB transition totalequals or exceeds the major SysB transition threshold, and if the SysBThmajor alarm is not already raised, the system raises the SysBTh majoralarm (unless the alarm has been disabled).

Remedial actionInvestigate the components that have high SysB transition counts, andreplace components as necessary.

If link hits occurred because of events at the far end, consider using theCNTRS RESET command to reset the SysB transition counter for each linkthat was affected.

XAC320 113

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 114: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Minor

• Major

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

Reason:<Reason Statement>

Grp Type Component SysB Cnts in last N hrs Sum Thresh

--- ---- --------- 42 36 30 24 18 12 06 00 --- ------

<Group><Type><Loc.>nn nn nn nn nn nn nn nn |

<Opt>nn<nn/nn><Sev>

Selected field descriptionsField Value Fixed or

VariableDescription

Sev One asterisk (*), twoasterisks (**), or ablank space

Variable One asterisk indicates that a SysBThminor alarm is raised. Two asterisksindicate that a SysBTh major alarm israised.

Severity One asterisk (*) ortwo asterisks (**)

Variable Displays the severity of the associatedalarm. One asterisk (*) indicates anSysBTh minor alarm; two asterisks(**) indicate an SysBTh major alarm.

Reportid XAC320 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

Reason "Cleared alarm raisedto Minor" or "Clearedalarm raised to Major"or "Minor alarm raisedto Major" or "Majoralarm lowered toMinor"

Variable A SysBTh alarm is raised, and theseverity has changed.

114 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 115: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Group PE SM IOlk IOhw Variable PE circuit pack

SM circuit pack

IO links

The IOhw category includes IOP andHIOP circuit packs, packlets, ports,and TOD devices.

Type PE, SM, IOP, HIOP,Tape, Disk, RTIF,OC3, CMIC, AMDI,ETHR, TOD

Variable Item type. OC3 is the equivalent ofAMDI.

Loc. < Slot > < Side > <Position > < Devicetype >

Variable Identifies the location of thecomponent, where < Slot > is numericin the range 1 to 18 and < Side > is Ffor front or R for rear. A < Position >value appears only if the component isa packlet or a packlet's port, link, ortime-of-day device. A < Device type >value appears only if the transitionswere by a port, link, or TOD device.

SysB cnts in last Nhrs

Eight numeric values,separated by spaces.Each is an integer inthe range 0 to 15.

Variable The number of SysB transitionsoccurring for the component in thecurrent six-hour interval (the rightmostvalue), and in each of the sevenpreceding six-hour intervals. Thecounter for each interval can count ashigh as 15.

Opt A plus sign (+) or ablank space

Variable A plus sign (+) appears in the Opt fieldif the Group is IOhw, and if the valuein the Sum field is a sum of transitionsfor multiple IOhw components that areassociated with the slot.

Sum Numeric Variable The sum of the SysB transitionsoccurring in the current six-hourinterval, and in the seven precedingsix-hour intervals.

Thresh Two numeric valuesseparated by a slash

Variable The two numeric values separated bya slash indicate the minor and majorSysB transition thresholds for thecomponent.

Active message exampleXAC320 NOV02 16:23:29 0019 FLT SysBTh Alarm Raised

XAC320 115

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 116: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Reason: Minor alarm cleared.

Grp Type Component SysB Cnts in last N hrs Sum Thresh

--- ---- --------- 42 36 30 24 18 12 06 00 --- ------

IOhw CMIC 4 R L 0 0 0 0 0 0 0 1 |+ 6 2/6 **

IOlk CMIC 4 R L Link1 0 0 0 0 0 0 0 1 | 1 2/8

IOhw RTIF 4 R U 0 0 0 0 0 0 0 1 |+ 6 2/6 **

IOhw RTIF 4 R U 0 0 0 0 0 0 3 1 |+ 6 2/6 **

Clear message examplen/a

Associated OM registers

• XETHRLNK (Ethernet links); XETHRPRT (Ethernet ports); XETHR(Ethernet packlets); XAMDILNK (AMDI links); XAMDIPRT (AMDIports); XAMDI (AMDI packlets); XCMICLNK (CMIC links); XCMICPRT(CMIC ports); XCMIC (CMIC packlets); XRTIFLNK (RTIF links);XRTIFPRT (RTIF ports); XRTIF (RTIF packlets); XATAPE (Tapepacklets); XADISK (Disk packlets); XAIOP (IOP, HIOP, and HCMICcircuit packs); XASM (SM circuit packs); XAPE (PE circuit packs); Thefollowing registers in the XACORE OM group are associated with thislog. Each register is pegged if its associated component (shown inparentheses) goes into the system-busy state.

XAC321Operating company personnel must insert the correct type of circuit pack(CP) in the XA-Core shelf slot matched for that type of CP. The system candetect the wrong type of CP in a shelf slot in real time (The system detectsa clock signal from the CP) or during a software audit.

The system generates the WgSlot (Shelf Audit Failure - CardConfiguration) log report if either of the following conditions occurs:

A shelf audit detects one or more CPs in the wrong XA-Core shelf slotpositions.

A shelf audit detects that a shelf slot configured for a CP is empty.

116 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 117: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The WgSlot (Shelf Audit Failure - Card Configuration) log report indicatesthe recommended action that operating company personnel can follow tocorrect the condition. When the condition clears, the system generates theWgSlot Cleared (Card Removed) (XAC627) log report.

A WgSlot (Shelf Audit Failure - Card Configuration) log report indicates aWgSlot Minor alarm condition. This alarm condition means that the wrongtype of CP is in a shelf slot, or a shelf slot configured for a CP is empty.

Event type: Fault (FLT)

Remedial actionIf the system detects a circuit pack (CP) in a shelf slot that is notprovisioned, remove the CP from that slot.

If the system detects a CP in a shelf slot configured for another type of CP,replace the CP with the correct CP type.

If the system detects no CP in a shelf slot that is configured for a CP, addthe correct CP type to the shelf slot.

AttributesAttribute Value

Severity Minor

FormatSeverity XACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

IMPACT:<System Impact Statement>

Shf Slot Side Expected Card/Pklt Detected Card/Pklt Action

nn nn c cccccc cccccc cccccc

nn nn c cccccc cccccc cccccc

nn nn c cccccc cccccc cccccc

nn nn c cccccc cccccc cccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

XAC321 117

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 118: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

One asterisk (*) indicates a minoralarm condition. The wrong type ofcircuit pack (CP) is in an XA-Coreshelf slot, or a shelf slot configured fora CP is empty.

Reportid XAC321 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core.

Shf 0 to 3 Variable The Shf field displays the positionnumber, within the Bay/Frame, of theXA-Core shelf.

Slot 01 to 18 Variable The Slot field displays the slotposition, within the shelf, that containsthe CP or packlet identified in the logreport.

Side F or R Variable The Side field displays the front (F)side or rear (R) side position of theshelf that contains the slot identified inthe log report.

Expected Card/Pklt Alphanumeric Variable The Expected Card/Pklt field displaysthe type of CP or packlet expected inthe shelf slot.

If the system expects no CP in theshelf slot, this field displays "none".

Detected Card/Pklt Alphanumeric Variable The Detected Card/Pklt field displaysthe type of CP or packlet detected inthe shelf slot.

If the system detects no CP in theshelf slot, this field displays "none".

Active message example* XAC321 NOV02 13:45:56 8800 FLT WgSlot (Shelf AuditFailure-Card Configuration)

IMPACT: The following slots contain unexpected cards:

118 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 119: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Shf Slot Side Expected Card/Pklt Detected Card/Pklt Action

1 4 F PE none Add

1 9 R none SM Remove

1 16 F PE IOP Replace

Clear message examplen/a

Associated OM registers

XAC322The system generates the Processor Element Trouble (PETrbl) log reportwhen a non-critical fault is detected on a Processor Element (PE) circuitpack (CP). A non-critical fault causes the PE CP to change state from in-service (InSv) to in-service trouble (IsTb).

The PETrbl log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the PETrbl Alarm Cleared log (XAC622)report.

The PETrbl log report generates a Card List when the system detects afault on more than one CP or packlet. The Card List displays other CPs orpacklets that operating company personnel need to check as possiblesources of the fault identified in the log report.

An PETrbl log report indicates a PEtrbl minor alarm condition. This alarmcondition means that a non-critical fault was detected on a PE CP. The PECP has changed state from InSv to IsTb.

Event type: Trouble (TBL)

Remedial actionPerform a manual in-service test on the PE CP that contains the fault to tryand clear the fault condition.

Replace the PE CP that contains the fault during a low traffic period on theswitch.

XAC322 119

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 120: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Critical

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resource

120 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 121: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

involved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

One asterisk (*) indicates a minoralarm condition. A non-critical faultwas detected on a PE CP. The PE CPhas changed state from InSv to IsTb

Reportid XAC322 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type TBL Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,

XAC322 121

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 122: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

122 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 123: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Active message example* XAC322 NOV01 15:22:28 0011 TBL PETrbl (Trouble)

IMPACT:

XAC322 123

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 124: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DESCRIPTION: State has changed from INSV to ISTB by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

PE IsTb HOST 01 A00 DPCC:00 01 04F NTLX02BA/nnnnnnnnnn

REASON: Non-critical XA-Core fault detected.

ACTION: Perform in-service test on the PE card.

Clear message examplen/a

Associated OM registers

XAC323The system generates the Shared Memory Trouble (SMTrbl) log reportwhen a non-critical fault is detected on a shared memory (SM) CP. Thenon-critical fault causes the SM CP to change state from in-service (InSv)to in-service trouble (IsTb).

The SMTrbl log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the SMTrbl Alarm Cleared log (XAC623)report.

The SMTrbl log report generates a Card List when the system detects afault on more than one CP or packlet. The Card List displays other CPsand packlets that operating company personnel need to check as possiblesources of the fault identified in the log report.

An SMTrbl log indicates an SMtrbl Minor alarm condition. This alarmcondition means that a non-critical fault was detected on a SM CP. The SMCP has changed state from InSv to IsTb

Event type: Trouble (TBL)

Remedial actionRun a manual in-service test on the SM CP that contains the fault to tryand clear the fault.

Replace the SM CP that contains the fault during a low traffic period on theswitch.

124 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 125: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Critical

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This field

XAC323 125

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 126: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

is displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

One asterisk (*) indicates a minoralarm. A non-critical fault wasdetected on an SM CP. An SM CPhas changed state from InSv to IsTb.

Reportid XAC323 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type TBL Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

126 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 127: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

XAC323 127

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 128: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Active message example** XAC323 NOC01 15:22:28 9700 TBL SMTrbl (Trouble)

IMPACT:

128 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 129: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DESCRIPTION: State has changed from INSV to ISTB by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

SM IsTb HOST 01 A00 DPCC:00 01 11F NTLX14CA/nnnnnnnnnn

REASON: Non-critical XA-Core fault detected.

ACTION: Perform in-service test on the SM card.

Clear message examplen/a

Associated OM registers

XAC324The system generates the Input/Output Trouble (IOTrbl) log report when anon-critical fault condition causes any of the following elements to changestate from in-service (InSv) to in-service trouble (IsTb):

high performance input/output processor (HIOP) circuit pack (CP)

high performance CMIC (HCMIC) circuit pack (CP)

input/output processor (IOP) circuit pack (CP)

IOP packlet (RTIF, CMIC, Disk or Tape packlet)

a link, port, or TOD clock

The IOTrbl log report indicates the recommended action that operatingcompany personnel can follow to correct the condition. When the conditionclears, the system generates the IOTrbl Alarm Cleared log (XAC624)report.

The IOTrbl log report generates a Card List when the system detects afault on more than one CP or packlet. The Card List displays other CPsand packlets that operating company personnel need to check as possiblesources of the fault identified in the log report.

A IOTrbl log report indicates an IOtrbl Minor alarm condition. This alarmcondition means that a non-critical fault condition has caused one of thefollowing to change state from InSv to IsTb: an HIOP CP, an HCMIC CP,an IOP CP, a packlet, a link, a port, or a TOD clock.

XAC324 129

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 130: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Event type: Trouble (TBL)

Remedial actionRun a manual in-service test on the CP or packlet that contains the fault totry and clear the fault.

Replace the CP or packlet that contains the fault during a low traffic periodon the switch.

AttributesAttribute Value

Severity • Critical

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

130 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 131: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

One asterisk (*) indicates a minoralarm. A non-critical fault has causedan IOP CP, packlet, link, port or TODclock to change state from InSv toIsTb.

Reportid XAC324 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type TBL Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

XAC324 131

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 132: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the IsTb component is a packlet or adevice on a packlet, this is a characteridentifying the packlet position (upperor lower). Possible values are U andL.

132 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 133: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,

XAC324 133

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 134: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Active message example* XAC324 NOV23 15:22:28 0011 TBL IOTrbl (Trouble)

IMPACT:

DESCRIPTION: State has changed from INSV to ISTB by SYSTEMaction.

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

IOP IsTb HOST 01 A00 DPCC:00 01 17F NTLX03BA/nnnnnnnnnn

REASON: Non-critical XA-Core fault detected.

ACTION: Perform in-service test on the IOP card.

Clear message examplen/a

Associated OM registers

XAC325A retrofit inactive boot key (RIBkey) is a tool that Installation personnel useduring an upgrade or cutover process of the XA-Core. A RIBkey connectsto the local port on each of the XA-Core reset terminal interfaces (RTIF).Installation personnel remove the RIBkeys when the switch of activity(SWACT) is complete and the XA-Core is the active core.

The system generates the RIBKEY Detected log report when a RIBkeydevice remains connected to an RTIF port on an XA-Core that is InSv. If anXA-Core restart occurs with RIBkey devices attached to the RTIF ports, theXA-Core system cannot return to active mode.

The RIBKEY Detected log report indicates the recommended action thatoperating company personnel can follow to correct the condition. When thecondition clears, the system generates the RIBkey Removed log (XAC625)report.

134 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 135: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

A RIBkey log indicates one of two alarm levels:

RIBkey Major alarm: RIBkey devices remain attached to both RTIF localports on an XA-Core that is the active core.

RIBkey Minor alarm: A RIBkey device remains attached to one RTIF localport on an XA-Core that is the active core.

Event type: Fault (FLT)

Remedial actionRemove remaining Ribkey (s) from the XA-Core.

AttributesAttribute Value

Severity • Major

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Event Text

IMPACT:<System Impact Statement>

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn/nns p ccccnncc/nnnnnnnn

ACTION:<Action Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Row Alphanumeric Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core.

XAC325 135

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 136: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CARD Type Character string Variable The Card Type field displays the typeof circuit pack (CP) or packletidentified in the log report.

State Character string Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site HOST Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

FL Numeric Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shf/Slot nn/nns p nn / =0 to 3 /nn =01 to 18 s =F orR p =U or L

Variable The Shelf (Shf) and Slot field identifythe shelf position within the bay, andslot position within the shelf, thatcontains the CP or packlet identified inthe log report.

nn/ = the shelf position number. /nn =the slot position number. s = sideposition, either the front (F) side orrear (R) side of the XA-Core shelf thatcontains the CP. p = the packletposition, either the upper (U) or lower(L) position, within an IOP CP. (Thepacklet position only displays whenthe indicated slot and side are from anIOP CP.).

Reportid XAC325he Alarm fielddisplays the severityof the alarm condition

Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

EqPEC/Serial Alphanumeric Variable The EqPEC/Serial field identifies theequipment product engineering code(EqPEC) and the serial number of theCP or packlet identified in the logreport.

136 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 137: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

ACTION Text string Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Severity One asterisk (*) Variable Displays the log severity.

Active message example* XAC325 DEC11 12:15:34 0011 RIBKEY (RIBKEY Detected)

IMPACT: XA-Core may not boot as active core.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

RTIF SysB HOST 01 A00 DPCC:00 01/15R U NTLX08AA/nnnnnnnn

ACTION: Remove remaining RIBKEY (s) from XA-Core.

Clear message examplen/a

Associated OM registers

XAC326The system generates the MS Link Configuration Mismatch (XAC326) logreport when there is a mismatch between the expected and the actualmessage switch (MS) link configuration. A link configuration mismatchoccurs when a CMIC link from a port on the CMIC hardware in the XA-Core shelf (an HCMIC circuit pack or an XA-Core OC-3 two-port Interfacepacklet) is connected to the wrong port on the OC-3 two port interfacepaddleboard in the message switch.

The MS Link Configuration Mismatch log report indicates therecommended action that operating company personnel can follow tocorrect the condition. When the condition clears, the system generates theMS Link Configuration Restored (XAC626) log report.

The MS Link Configuration Mismatch log does not indicate an alarmcondition.

Event type: Fault (FLT)

XAC326 137

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 138: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionCheck the MS Link Configuration.

AttributesAttribute Value

Severity Indeterminate

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

IMPACT:<System Impact Statement>

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn/nns p ccccnncc/nnnnnnnnn

PORT: n

REASON:<Reason statement>

SHELF MS CARD PORT

EXPECTED: nn nn nn nn

ACTUAL: nn nn nn nn

ACTION:<Action Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC326 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

IMPACT Text string Variable The Impact field describes the impactof the condition on the XA-Core.

CARD Type Character string Variable The Card Type field displays the typeof circuit pack (CP) or packletidentified in the log report.

138 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 139: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

State Character string Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site HOST Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

FL Numeric Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shf/Slot nn/nns p where: nn/=0 to 3 /nn=01 to 18s=F or R p=U or L

Variable The Shelf (Shf) and Slot field identifythe shelf position within the bay, andslot position within the shelf, thatcontains the CP or packlet identified inthe log report.

where:

nn/=the shelf position number.

/nn=the slot position number.

s=side position, either the front (F)side or rear (R) side of the XA-Coreshelf that contains the CP.

p=the packlet position, either theupper (U) or lower (L) position, withinan IOP CP. (The packlet positiondisplays only if the CMIC link issupported by an OC-3 two portpacklet.)

EqPEC/Serial Alphanumeric Variable The EqPEC/Serial field identifies theequipment product engineering code(EqPEC) and the serial number of theCP or packlet identified in the logreport.

PORT 0 to 1 Variable The Port field indicates the portnumber on the CMIC packlet.

XAC326 139

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 140: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

REASON Text string Variable The Reason field describes the causeof the condition reported in the logreport.

EXPECTED Character string Variable The Expected field indicates theexpected MS Link configuration.

This field identifies the expected MSshelf number, MS, MS Card numberand MS port number.

ACTUAL Character string Variable The Actual field indiciates the actualMS Link configuration.

This field identifies the actual MS shelfnumber, MS, MS Card number andMS port number.

SHELF 0 to 3 Variable The shelf field identifies the shelfposition number on the MS.

MS 0 or 1 Variable The MS field identifies the MS.

CARD Character string Variable The Card field identifies the shelf slotnumber on the MS.

PORT 0 or 1 Variable The MS Port field identifies the portnumber on the MS.

ACTION Text string Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Active message exampleXAC326 NOV03 17:15:16 8800 FLT MS Link ConfigurationMismatch

IMPACT: Possible loss of messaging.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

CMIC InSv HOST 00 A00 DPCC:00 01/15R L NTLX05AA/nnnnnnnnn

PORT: 0

REASON: Mismatch between expected and actual MS LinkConfiguration.

SHELF MS CARD PORT

140 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 141: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

EXPECTED: 0 1 24 0

ACTUAL: 0 0 25 0

ACTION: Check MS Link Configuration.

Clear message examplen/a

Associated OM registers

XAC327Operating company personnel must insert the correct circuit pack (CP) inthe XA-Core shelf slot matched for the CP type. The system can detect thewrong type of CP in a shelf slot in real time (The system detects a clocksignal from the CP) or during a software audit.

The system generates the WgSlot (Card Inserted Into Wrong Slot) logreport when software detects the insertion of a CP into the wrong shelf slotin real-time (The system detects a clock signal from the CP).

The WgSlot (Card Inserted Into Wrong Slot) log report indicates therecommended action that operating company personnel can follow tocorrect the condition. When the condition clears, the system generates theWgSlot Cleared (Card Removed) log (XAC627) report.

The WgSlot (Card Inserted Into Wrong Slot) log report indicates a WgSlotMinor alarm condition. This alarm condition means that a CP was insertedinto the wrong shelf slot in real-time (The system detects a clock signalfrom the CP).

Event type: Fault (FLT)

Remedial actionRemove the card.

AttributesAttribute Value

Severity Minor

FormatSeverity XACnnn mmmdd hh:mm:ss nnnn Event Type Event Text

DESCRIPTION:<Description Statements>

XAC327 141

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 142: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Shf Slot Side TYPE PEC

nn nn c cccc cccccccc

ACTION:<Action statements>

Selected field descriptionsField Value Fixed or

VariableDescription

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

One asterisk (*) indicates a minoralarm. A CP was inserted into thewrong shelf slot in real-time.

Reportid XAC327 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thecondition identified in the log report.

Shf 0 to 3 Variable The Shelf (Shf) field identifies the XA-Core shelf position.

Slot 01 to 18 Variable The Slot field identifies the slotposition, within the shelf, that containsthe CP identified in the log report.

Side F or R Variable The Side field identifies the front (F)side or rear (R) side of the shelf thatcontains the slot.

TYPE Character string Variable The TYPE field identifies the type ofCP detected in the shelf slot.

PEC Alphanumeric Variable The PEC field displays the productengineering code of the CP detectedin the slot.

Active message example* XAC327 NOV02 13:45:56 1700 FLT WgSlot (Card Inserted IntoWrong Slot)

DESCRIPTION: Card detected in the following unprovisionedslot.

142 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 143: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Shf Slot Side TYPE PEC

00 12 F PE NTLX02AA

ACTION: Remove the card

Clear message examplen/a

Associated OM registers

XAC329The system generates the Ethernet log (XAC329) report when any of thefollowing conditions occur

There is a loss of communication between the XA-Core and the ethernetnetwork as a result of any single link failure.

There is a loss of ethernet link redundancy.

IP routing and maintenance (IRM) disables the link as a result of a problemthat occurs while trying to bring the link into service.

Failure to set active IP address on link because one or more of the activeIP addresses entered in table CMIPADDR could not be bound onto theethernet packlet.

The IRM comm audit has failed on the link because the comm audit on theethernet link has detected a problem with the connection to the edgedevice.

An Ethernet log report indicates a ETHR alarm condition.

Event type: Fault (FLT)

Remedial actionIf the state of the ethernet hardware supporting the ethernet link (anethernet packlet or an HIOP circuit pack or an HCMIC circuit pack) isManB, attempt to return it to service. Replace if faulty.

If the ethernet packlet state is Cbsy because an Input/Output Processor(IOP) circuit pack (CP) is out-of-service, ensure the identified IOP circuit isin-service.

XAC329 143

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 144: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

If the state of the ethernet hardware supporting the ethernet link (anethernet packlet or an HIOP circuit pack or an HCMIC circuit pack) isSysB, attempt to return it to service. Replace if faulty.

If the state of the ethernet hardware supporting the ethernet link (anethernet packlet or an HIOP circuit pack or an HCMIC circuit pack) is in-service (InSv) or in-service trouble (Istb), perform an in-service test on theaffected hardware. Replace if faulty.

If the state of the ethernet hardware supporting the ethernet link (anethernet packlet or an HIOP circuit pack or an HCMIC circuit pack) isunknown and a state change has occurred on the ethernet hardware or ona port or link, ensure that the ethernet hardware InSv. Check the integrityof the ethernet links.

If an ethernet port or link state is ManB, attempt to return to service theethernet port or link.

If an ethernet port or link state is SysB, contact next level of support ifproblem persists.

If the XA-Core system is in split mode, take no action. The ethernethardware (an ethernet packlet or an HIOP circuit pack or an HCMIC circuitpack), port and link will return to service when the system exits split mode.

If the link continues to be disabled by IRM, contact your next level ofsupport.

If failure to set active IP address on the link continues, contact your nextlevel of support.

If IRM comm audit continues to fail on the link, contact your next level ofsupport.

AttributesAttribute Value

Severity • Critical

• Major

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Log Title

IMPACT:<System Impact Statement>

144 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 145: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

REASON:<Reason Statement>

ACTION:<Action Statement>

FAULT RECORD ID: hhhhhhhh

Check the following card(s) for possible source of fault.

Weight Type Site FL Row Bay Shf/Slt/Pk/Dv EqPEC/Serial

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

.... ..

nnn% cccc cccc nn cnn cccc:nn nn nnc c n nnnnccnn/cccccccccccc

Selected field descriptionsField Value Fixed or

VariableDescription

REASON Text string (optional) Variable The Reason field describes the causeof the condition identified in the logreport. This field is not displayed if thestate change was initiated by the user.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Fault Record Id 8 hexadecimalcharacters (optional)

Variable A hexadecimal identifier thatreferences an entry in the XA-CoreFault Query Tool database. (This fieldis displayed only if the conditionidentified in the log report was causedby a recorded hardware fault.)

XAC329 145

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 146: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Cardlist Variable field(optional)

Variable The Cardlist field displays other CPsor packlets that operating companypersonnel need to check as possiblesources of the fault identified in the logreport.

The Cardlist field displays the card orpacklet weight (probability, shown asa percentage, that the CP or packletcontains a fault), card type, state, site,floor, row, bay, shelf and slot position,the product engineering code andserial number for each CP or packlet.

A cardlist is displayed only if thenumber of CPs or packlets involved inthe fault report was greater than one.

Severity Three asterisks (***)Two asterisks (**)

Variable Displays the severity of the associatedalarm.

Three asterisks (***) indicate a criticalalarm condition. There are insufficientlinks in service to maintain theengineered capacity. This can indicatea loss of call origination at the CallServer.

Two asterisks (**) indicate a majoralarm condition. The minimum numberof ethernet links remain in-service.There is a loss of link redundancy.

Reportid XAC329 Variable The reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core. (Thisline is generated only if the statechange has a negative impact.)

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

146 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 147: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

XAC329 147

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 148: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the ethernet links are supported byethernet packlets, this is a characteridentifying the packlet position (upperor lower). Possible values are U andL. If the links are supported by HIOPor HCMIC circuit packs, the field isblank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message example** XAC329 OCT29 15:22:28 1199 FLT ETHR (Ethernet)

IMPACT: 2 of 4 Ethernet links on XA-CORE are in-service .

DESCRIPTION: State has changed from INSV to MANB by MANUALaction.

148 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 149: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

ETHRManB HOST 01 A00 DPCC:00 00 14R L NTLX09AA/nnnnnnnnnn

REASON: Ethernet link(s) are out of service due to manuallybusied packlet.

ACTION: Attempt to RTS ETHR packlet.

FAULT RECORD ID: 12345678

Clear message examplen/a

Associated OM registers

XAC330The system generates log report XAC330 when it detects a firmware (FW)mismatch. The firmware version of the field replaceable unit (FRU) and thecurrent version recorded in XAFWLOAD data schema table do not match.

A Firmware Mismatch log report indicates an FWvers Major alarmcondition. This alarm indicates a firmware mismatch.

The system compares the FW version from the FRU and the FW versionrecorded in the XAFWLOAD data schema table when one of the followingactions occur:

Operating company personnel manually issue a query card command.

The system performs an audit and automatically queries the card.

Remedial actionCheck the datafill in the XAFWLOAD data schema table. If the firmwareversion recorded in the data schema table is correct, upgrade the firmware.

AttributesAttribute Value

Severity Major

Formatn/a

XAC330 149

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 150: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Severity One, two, or threeasterisks, or blank

Variable Displays the log severity.

Reportid XAC330 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core.

< FRU > character string Variable Indicates the FRU type PE, IOP,HIOP, CMIC, ETHR, or AMDI.

< state > character string Variable Indicates the FRU state is InSv, SysB,ManB, CBsy or ISTb.

< location > character string Variable Indicates the location of XA-Core.

< shelf > integers Variable Indicates the shelf number. The shelfnumber is 0, 1, 2 or 3.

< slot > integers Variable Indicates the slot number.

< side > character string Variable Indicates the slot side is front or rear.

< PEC > alphanumeric Variable Indicates the FRU productengineering code in the formatNTLXxxxx.

< # > numeric Variable Indicates the FRU serial number.

< actualFW > character string Variable Indicates the actual FRU FW version.

< table_entryFW > character string Variable Indicates the FW version datafill in theXAFWLOAD data schema table.

Active message example**XAC330 OCT27 18:29:47 8300 FLT FW version mismatch

IMPACT: Wrong FW version on a IOP card

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

IOP InSv HOST 01 A000 DPCC:00 01 17F NTLX03BA/Not avail

REASON: FW version on card is XAIO01AA, should be XAIO01AG.

150 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 151: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

ACTION: Upgrade the firmware.

Clear message examplen/a

Associated OM registers

XAC333The system generates the log XAC333 if the firmware(FW) loading processfails. The followingdescriptions apply:

New FW fails to load and there is no valid FW in FLASH.

New FW fails to load and the system recovers the old firmware.

Reason

The reason field provides the specific reason for the failure of the LoadFWcommand. The following table lists the reasons that can be displayed.

Reasons for the failure of the LoadFW command

• Bank not programmable

• File is nonexistent

• Invalid fru location

• Memory allocation failed

• No problems were detected

• Resource unavailable

• Table entry not found

• Unknown file type

• Unknown hardware type

• Unreadable file

• Volume nonexistent

• Firmware mismatch detected

• Firmware soaking in progress

• FW not compatible with card type

• Obsolete FW

• Copy FW to SM failed

XAC333 151

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 152: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

• Copy FW to SM failed: bad FW load

• Copy FW to SM failed: could not extract FW from file

• Copy FW to SM failed: could not read FW from other card

• Bank erase failed

• Bank erase failed: no communication with card

• Bank erase failed: timeout

• Bank program failed

• Bank program failed: no communication with card

• Bank program failed: timeout

• Test failed

• Test failed: no communication with card

• Test failed: could not reset card

• Test failed: could not swap banks

• FW Upgrade aborted with roll back

• FW Upgrade aborted with NO roll back

• FW Upgrade failed with roll back

• Packlet setup failed

• FW Upgrade NOT supported

Remedial actionIf the action reports NO VALID FW IN FLASH, load the FW manually.

If the action reports FW version could not be loaded, return the FRU intoservice and contact the next level of support.

If the impact text of the log reports that the LoadFW command wasrejected, follow the instructions recorded in the reason and action text.Check the XAFWLOAD table datafill.

AttributesAttribute Value

Severity Indeterminate

Formatn/a

152 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 153: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Severity One, two, or threeasterisks, or blank

Variable Displays the log severity.

Reportid XAC333 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core.

< FRU > character string Variable Indicates the FRU type is PE, IOP orCMIC.

< state > character string Variable Indicates the FRU state is InSv, SysB,ManB, CBsy or ISTb.

< location > character string Variable Indicates the location of XA-Core.

< shelf > integer Variable Indicates the shelf number is 0, 1, 2 or3.

< slot > integer Variable Indicates the slot number is 2 to 17.

< side > character string Variable Indicates the slot side is front or rear.

< PEC > alphanumeric Variable FRU product engineering codeNTLXxxxx in format.

< # > numeric Variable Indicates the FRU serial number.

Active message example** XAC333 OCT27 18:02:06 7300 FLT FW loading failed

IMPACT: LoadFW command failed.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

PE ManB HOST 01 A00 DPCC:00 00/04F NTLX02AA/Not available

REASON: FW not compatible with card type

ACTION: NO VALID FW IN FLASH!

Load previous version of FW. Execute LoadFW current.

* XAC333 OCT27 18:01:46 6800 FLT FW loading failed

XAC333 153

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 154: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

IMPACT: LoadFW command failed.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

PE ManB HOST 01 A00D PCC:00 00/04F NTLX02AA/Not available

REASON: FW not compatible with card type

ACTION: RTS the card.

Contact next level of support.

Clear message examplen/a

Associated OM registers

XAC335The system generates the OC-3 packlet fault log only after a restart. Thelog is intended to inform the user that table XAMDILNK must be datafilled ifthe AMDI packlet is only datafilled in table XACINV.

An OC-3 packlet faukt log indicates one of two alarm levels:

AMDI Critical Alarm: There is no communication between the XA-Core andat least one SMG peripheral.

AMDI Major Alarm: There is a loss of AMDI packlet link redundancybetween the XA-Core and SMG peripherals.

Event type: Fault (FLT)

Remedial actionEnsure that table XAMDILNK is datafilled with the correct AMDI packletinformation as found in table XACINV.

AttributesAttribute Value

Severity • Critical

• Major

FormatXAC### mmmdd hh:mm:ss ssdd Event type Event text

154 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 155: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Impact: description text

Slot Side Position

<C><C><C>

Action: suggested action text

Active message exampleXAC335 OCT07 00:00:00 8700 FLT Unknown OC-3 packlet

IMPACT: OC-3 packlet not provisioned.

Slot Side Position

12 R L

ACTION: Ensure table XAMDILNK is provisioned.

Clear message examplen/a

Associated OM registers

XAC337The system generates the Baseln Alarm Raised log report when either ofthe following things occurs:

The system raises the Baseln major alarm, indicating that it has detectedan item of hardware or firmware that is incompatible with the baseline andexception-list information in tables FWINV and PECINV.

The Baseln major alarm is already raised, but the system has detected achange in the list of non-baseline items in the system. For example, thesystem has detected that a new non-baseline item has been added, or ithas detected that an item that was previously non-baseline has been fixed,but one or more other non-baseline items still remain.

Event type: Fault (FLT)

Remedial actionInvestigate to find out which hardware and/or firmware is incompatible withthe baseline and exception-list information in tables FWINV and PECINV.For instructions on how to investigate, see the procedure for clearing aBaseln major alarm. The procedure is in the Nortel XA-Core Fault andPerformance Management (297-8991-510).

XAC337 155

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 156: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Update the hardware or firmware as required.

AttributesAttribute Value

Severity Major

FormatSeverity XAC337 mmmdd hh:mm:ss ssdd Event Type Log Title

Card/packlets below have non-baseline HW and/or FW.

Investigate items with "N*" or U* in OK column.

- HW vs. PECINV - -- Firmware vs. FWINV --

Type FRU PEC+Release BL OK Typ Version Baseline OK

---- ------- ----------- -- -- --- -------- -------- --

aaaa aaaaaaa aaaaaaaaaaa aa aa aaa aaaaaaaa aaaaaaaa aa

aaaa aaaaaaa aaaaaaaaaaa aa aa aaa aaaaaaaa aaaaaaaa aa

aaaa aaaaaaa aaaaaaaaaaa aa aa aaa aaaaaaaa aaaaaaaa aa

.

.

.

Selected field descriptionsField Value Fixed or

VariableDescription

Severity Two asterisks (**) Variable Displays the severity of the associatedalarm.

Reportid XAC337 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type FLT Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string: "BaselineAlarm Raised"

Variable A text string describing the title of thelog report.

156 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 157: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Type Text string Variable Identifies the type of circuit pack orpacklet.

FRU Slot: integer in therange 1 to 18 Side: Ffor front or R for rearPacklet-position: U forupper or L for lower

Variable Identifies the location of the circuitpack or packlet in the XA-Core shelf,in the format: < slot > < side > <packlet-position > .

PEC+Release PEC: six-characteralphanumeric Suffix:two characteralphabetic Release:two-digitalphanumeric

Variable Identifies the hardware in the format: <PEC > < suffix > < release > .

BL Two-characteralphanumeric

Variable The baseline hardware release for thehardware, as listed in table PECINV.

OK Y, N*, or U* Variable Indicates whether the hardware iscompatible with the baseline andexception-list information listed intable PECINV. Y means yes. N*means no. U* means unknown, whichindicates that the table does notcontain an entry for the hardwareitem.

Typ FW or DLL Variable Indicates the type of firmware load.Every hardware items that takesfirmware takes an FW firmware load.Only HIOP circuit packs take DLLfirmware loads as well.

Version Eight-characteralphanumeric

Variable Identifies the firmware load that iscurrently in the hardware item.

Baseline Eight-characteralphanumeric

Variable The baseline firmware load for thehardware, as listed in table FWINV.

OK Y, N*, or U* Variable Indicates whether the current firmwareis compatible with the baseline andexception-list information listed intable FWCINV. Y means yes. N*means no. U* means unknown, whichindicates that the table does notcontain an entry listing the firmwarefor the hardware item.

XAC337 157

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 158: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleXASKY07GH ** XAC337 JAN15 22:55:48 6100 FLT Baseln AlarmRaised

Card/packlets below have non-baseline HW and/or FW.

Investigate items with "N*" or U* in OK column.

- HW vs. PECINV - -- Firmware vs. FWINV --

Type FRU PEC+Release BL OK Typ Version Baseline OK

---- ------- ----------- -- -- --- -------- -------- --

HIOP 14 R NTLX04CA 02 02 Y FW XHIO02AH XHIO02AH Y

DLL XHIO02AI XHIO02AH N*

PE 4 F NTLX02DA 01 02 N* FW XAPE02AB XAPE02AB Y

Clear message examplen/a

Associated OM registers

XAC400The system generates the XA-Core Summary Report log (XAC400) toprovide a summary of performance and maintenance information about theXA-Core for a 24-hour period.

If the summary report is generated at a time when the Config minor alarmis raised, the summary report includes the following sentence: "System isstill in an upgrade process mode." (The Config minor alarm indicates thatthe XA-Core contains one or more NTLX02DA PE circuit packs and one ormore earlier-model PE circuit packs.)

Remedial actionn/a

AttributesAttribute Value

Severity • Warning

• Minor

158 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 159: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatXAC400 mmmdd hh:mm:ss ssdd INFO XA-Core Summary Report

TOTAL TRAPS IN LAST 24 HOURS: n

AVERAGE TRAPS PER MINUTE: n

LAST RESTART: MANUAL RELOAD mmm-dd hh:mm:ss

FAULT EVENT COUNTERS FOR LAST 24 HOUR PERIOD

===================================================

PE Fault Events : n

SM Fault Events : n

IOP Fault Events : n

DISK Fault Events : n

TAPE Fault Events : n

RTIF Fault Events : n

Loc Port Fault Events: 0

Rem Port Fault Events: n

CMIC Fault Events : n

SYSTEM WARM restarts : n

MANUAL WARM Restarts : n

SYSTEM COLD Restarts : n

MANUAL COLD Re starts : n

XAC Trap Events : n

CURRENTLY DISABLED XA-CORE ALARMS

=============================================

<alarm><alarm>

CURRENTLY SOAKING FW

XAC400 159

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 160: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

=============================================

<card><slot><side><packlet position>

<card><slot><side><packlet position>

<card><slot><side><packlet position>

<card><slot><side><packlet position>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid Alphanumeric Variable Indicates the log group (XAC) andidentification number of the log.

Event Type Character string Variable Indicates the type of event identified inthe log report.

Event Text Text string Variable Indicates describes the type of eventidentified in the log report.

TOTAL TRAPS INTHE LAST 24HOURS

Numeric Variable Indicates the total number of TRAPSdetected in the last 24 hours.

AVERAGE TRAPSPER MINUTE

Numeric Variable Indicates the average number ofTRAPS detected per minute.

LAST RESTART intitiator=MANUAL, orSYSTEM restarttype=WARM, COLD,or RELOAD yyyy/mm/dd hh:mm:ss.nnn ccc.

Variable This field displays the followinginformation about the last restart:

initiator=The trigger that began thelast restart can either be MANUAL orSYSTEM restart.

restart type =The type of restart canbe WARM, COLD, or RELOADrestart.

yyyy/mm/dd=The year, month and dayof the last restart.

hh:mm:ss.nnn ccc.=The hour, minute,second, millisecond, and day of thelast restart.

FAULT EVENTCOUNTERS FORLAST 24 HOURPERIOD

Numeric Variable Indicates the number of XA-Coreevents for the last 24 hour period.

The system counts the followingevents for the last 24 hour period:

PE Fault Events

SM Fault Events

160 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 161: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

IOP, HIOP, and HCMIC Fault Events

DISK Fault Events

TAPE Fault Events

RTIF Fault Events

CMIC Fault Events

SYSTEM WARM Restarts

MANUAL WARM Restarts

SYSTEM COLD Restarts

MANUAL COLD Restarts

XAC Trap Events

CURRENTLYDISABLED XA-COREALARMS

Character string Variable Operating company personnel candisable XA-Core alarms fromdisplaying at the MAP.

This field displays alarms that arecurrently disabled.

CURRENTLYSOAKING FW

Character string Variable Indicates the position of the card/packlet that is currently soakingfirmware (FW).

Active message exampleXAC400 OCT27 00:00:00 5600 INFO XA-Core Summary Report

TOTAL TRAPS IN LAST 24 HOURS: 0

AVERAGE TRAPS PER MINUTE: 0

LAST RESTART: MANUAL RELOAD OCT-26 18:04:15

FAULT EVENT COUNTERS FOR LAST 24 HOUR PERIOD

================================================

PE Fault Events : 2

SM Fault Events : 0

IOP Fault Events : 3

DISK Fault Events : 0

XAC400 161

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 162: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TAPE Fault Events : 0

RTIF Fault Events : 0

Loc Port Fault Events: 0

Rem Port Fault Events: 0

CMIC Fault Events : 1

SYSTEM WARM restarts : 0

MANUAL WARM Restarts : 0

SYSTEM COLD Restarts : 0

MANUAL COLD Restarts : 0

XAC Trap Events : 0

CURRENTLY DISABLED XA-CORE ALARMS

================================================

FWsoak FWvers

CURRENTLY SOAKING FW

================================================

CMIC 4 rear lower

Clear message examplen/a

Associated OM registers

XAC413The system performs a daily Routine Exercise (REx) test to make sure thatthe XA-Core equipment is functioning correctly. The system can perform aREx test, or operating company personnel can perform a manual REx test.

The system generates the RExSch (REx Schedule Failure) log (XAC413)report when two or more consecutive system XA-Core REx tests arecancelled.

162 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 163: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

The RExSch (REx Schedule Failure) log indicates the recommendedaction that operating company personnel can follow to correct thecondition. When the condition clears, the system generates the RExSchAlarm Cleared log (XAC613) report.

A RExSch (REx Schedule Failure) log report indicates a RExSch Minoralarm condition. This alarm condition means that two or more consecutivesystem REx tests are cancelled.

Event type: Summary (SUMM)

Remedial actionRun a system REx test to clear the alarm.

AttributesAttribute Value

Severity Minor

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Event Text

DESCRIPTION:<Description Statement>

ACTION:<Action Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

One asterisk (*) indicates a minoralarm condition. There is acancellation of two or moreconsecutive XA-Core system RExtests.

Reportid XAC413 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type SUMM Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

XAC413 163

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 164: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DESCRIPTION Text string Variable The Description field describes thesystem condition identified in the logreport.

ACTION Text string Variable The Action field displays therecommended action that operatingcompany personnel can follow tocorrect the condition identified in thelog report.

Active message example* XAC413 FEB13 11:02:10 0011 SUMM RExSch (REx Schedule)

DESCRIPTION: XA-Core REx has not run for 2 days

ACTION: Enable REx in table RExSched

Clear message examplen/a

Associated OM registers

XAC415The system performs a system routine exercise (SREx) test, or operatingcompany personnel perform a manual REx test to make sure that XA-Corehardware is functioning correctly.

The system generates the Routine Exercise (REx) Report log (XAC415)report after a REx test finishes. The REx Report log report providesoperating company personnel with a summary of the REx results.

No alarm is associated with the REx Report log.

Event type: Information (INFO)

Remedial actionIf the REx test fails, check for other XA-Core logs that report fault eventsfor more detailed information about faults and their effect on the system.

164 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 165: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Warning

• Major

• Critical

FormatThe usual format for log XAC415 is as follows:The usualformat for log XAC415 is as follows:

XACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

INITIATOR CLASS RESULT

<cccccc><cccc><cccccc>

Device Position Test Result Fault/Reason

<cccc><ccccccccccccccc><cccc><cccccc><ccccccccccc>

<cccc><ccccccccccccccc><cccc><cccccc><ccccccccccc>

<cccc><ccccccccccccccc><cccc><cccccc><ccccccccccc>

<cccc><ccccccccccccccc><cccc><cccccc><ccccccccccc>

<cccc><ccccccccccccccc><cccc><cccccc><ccccccccccc>

Image Test Result:<image test result><RExFlt raised/cleared>

If the system does not execute the SREx test for somereason, it uses the following alternative format to explainwhy:If the system does not execute the SREx test for somereason, it uses the following alternative format to explainwhy:

XACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

INITIATOR CLASS RESULT

<cccccc><cccc><cccccc>

Reason:<reason>

XAC415 165

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 166: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC415 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

INITIATOR Manual or System Variable The Initiator field indicates if the RExtest is system or manually triggered.

CLASS All, Base, Full, IO, PE,or SM

Variable The Class field displays the REx testclass used in the REx test.

RESULT Passed, Failed,Aborted, or Not Run

Variable The Result field displays the result ofthe REx test.

Device Text string Variable Identifies the circuit pack or packlet.

Position < slot > < side > <packlet > < device > <slot > is numeric <side > is F or R <packlet > is U or L <device > is a string

Variable The Position field displays the positionof the item being tested.

The system displays a < packlet >value only if the item being tested is apacklet or a device on a packlet.

The system displays a < device >value only if the item being tested is alink, port, or time-of-day device

Test InSv or OOS Variable The Test field identifies the type ofREx test performed on CPs andpacklets.

InSv=An InSv Rex test is performedon CPs and packlets that are in-service.

OOS=An OOS Rex test is performedon CPs and packlets that operatingcompany personnel have taken out-of-service (OOS).

Result Passed, Failed, NotRun, Aborted, orStarting

Variable The Result field displays the results ofthe REx test for the equipmentidentified.

Fault/Reason Fault values:Questionable, Non-Critical, Conditional,or Critical

Variable The "Fault" displays the severity ofany faults found for the CPs orpacklets identified in the REx Report.The "Reason" is a string.

166 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 167: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Image Test Result passed, failed, notrun, aborted, orstarting

Variable The Image Test Result field displaysthe results of an Image Test.

RExFlt raised/cleared RExFlt alarm raisedor RExFlt alarmcleared

Variable This is an optional field. It is displayedif a RExFlt alarm is raised or clearedduring a REx test.

Active message exampleXAC415 DEC11 16:05:41 1300 INFO Routine Exercise (REx)Report

INITIATOR CLASS RESULT

Manual Full Passed

Device Position Test Result Fault/Reason

PE 12 F InSv Passed

PE 6 F InSv Passed

PE 5 F InSv Passed

PE 4 F InSv Passed

SM 10 F InSv Passed

SM 8 R InSv Passed

SM 9 F InSv Passed

SM 8 F InSv Passed

SM 7 F InSv Passed

TOD 15 R L TOD0 InSv Passed

TOD 15 R L TOD1 InSv Passed

CMIC 15 R L Link0 InSv Passed

CMIC 15 R L Link1 InSv Passed

CMIC 15 R L InSv Passed

XAC415 167

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 168: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

RTIF 15 R 0 Port0 InSv Passed

RTIF 15 R U Port1 InSv Passed

RTIF 15 R U InSv Passed

IOP 15 R InSv Passed

AMDI 14 R Port0 InSv Passed

AMDI 14 R Port1 InSv Passed

ETHR 14 R Link InSv Passed

ETHR 14 R Port InSv Passed

HIOP 14 R InSv Passed

AMDI 5 R Port0 InSv Passed

AMDI 5 R Port1 InSv Passed

ETHR 5 R Link InSv Passed

ETHR 5 R Port InSv Passed

HIOP 5 R InSv Passed

TOD 4 R L TOD0 InSv Passed

TOD 4 R L TOD1 InSv Passed

CMIC 4 R L Link0 InSv Passed

CMIC 4 R L Link1 InSv Passed

CMIC 4 R InSv Passed

RTIF 4 R U Port0 InSv Passed

RTIF 4 R U Port1 InSv Passed

RTIF 4 R U InSv Passed

IOP 4 R InSv Passed

.

168 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 169: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

.

.

Image Test Result: Image OK

XAC415 JAN12 17:06:42 1400 INFO Routine Exercise (REx)Report

INITIATOR CLASS RESULT

Manual All Not Run

Reason: Components have gone SYSB in the last 48 hrs.

Clear message examplen/a

Associated OM registers

• XARXALL; XARXFULL; XARXBASE; XARXABRT; XARXIO; XARXSM;XARSMPXU; XARXPE

XAC418The system issues this log to indicate that it tried to enter split mode butfailed. The log also offers basic guidance for solving the problem.

When the system enters split mode, it is separated into two "sides", andactive side and an inactive side. Each side has enough PE circuit packsand SM circuit packs to function properly.

Split mode is used on several occasions, including the following:

an image test

during mtc swact

during norestart swact

during restart swact

during loadmate

during a One Night Process (ONP)

XAC418 169

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 170: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Entry into split mode can be ordered by the user, It can also be ordered bythe system, for example, during a system REx test. If entry into split modefails, you should understand the cause before reattempting the operation.

Remedial actionResolve the problem that prevented entry into split mode. The informationin the Reason and Action fields provides basic guidance about how toresolve the problem. If you do not understand the information in theReason and Action fields, seek help from the next level of support.

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

DESCRIPTION: XA-Core has failed to enter Split Mode.

Some SM and PE cards may be unavailable for call

processing until recovery is complete.

INITIATOR:<Initiator statement>

REASON:<Reason Statement>

ACTION:<Action Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC418 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

INITIATOR Text string Variable The Initiator field specifies the actionthat ordered entry into split mode.

170 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 171: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

REASON Text string Variable The Reason field specifies the reasonfor the failure to enter split mode. Ifyou do not understand the contents ofthis field, seek help from the next levelof support.

ACTION Text string Variable The Action field provides basicguidance for resolving the problemthat prevented entry into split mode. Ifyou do not understand the contents ofthis field, seek help from the next levelof support.

Active message exampleXAC418 JAN18 10:39:26 2900 INFO Split (Entry to Split ModeFailed)

DESCRIPTION: XA-Core has failed to enter Split Mode.

Some SM and PE cards may be unavailable for call

processing until recovery is complete.

INITIATOR: Action initiated by a Image Test.

REASON: PE call capacity levels are too high to supportSplit.

ACTION: Check call capacity levels before reattemptingSplit.

Clear message examplen/a

Associated OM registers

XAC420The system generates the SysBTh Ctrl Changed log report when either ofthe following events occurs.

A user resets the SysB transition counters by using the CNTRS RESETcommand. (The CNTRS RESET command is available in several MAPlevels. For details, see the chapter titled "XA-Core MAP levels and userinterfaces" "title"

XAC420 171

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 172: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

in this document.)

Nortel changes the SysB-transition thresholds that govern when thesystem raises the SysBTh alarms.

See the description of log XAC320 in this chapter for a list of thecomponents for which the system maintains counts of system-busy (SysB)transitions, and for a description of the conditions in which the systemraises SysBTh minor and SysBTh major alarms.

Remedial actionn/a

AttributesAttribute Value

Severity • Major

• Minor

• Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

Reason:<Reason Statement>

<Comment>

Grp Type Component SysB Cnts in last N hrs Sum Thresh

--- ---- --------- 42 36 30 24 18 12 06 00 --- ------

<Group><Type><Loc.>nn nn nn nn nn nn nn nn |<Opt>nn<nn/nn><Sev>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC420 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

172 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 173: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Reason "Counters reset fromcommand: < Group >< Slot > < Side > <Position > " or "Alarmthresholds changedfor: < Group > "

Variable For a description of < Group > , seethe description of the Group field inthis table. For descriptions of < Slot > ,< Side > , and < Position > , see thedescription of the Loc. field in thistable.

Comment "Before countersreset:" or "Old values:minor = < nn > , major= < nn > New values:minor = < nn > , major= < nn > Beforethresholdchange:"where eachinstance of nn is aninteger in the range 1to 32767

Variable This comment appears if the Reasonfield contains "Counters reset fromcommand: < location > ".

This comment appears if the Reasonfield contains "Alarm thresholdschanged for < Group > ".

Group PE SM IOlk IOhw Variable PE circuit pack

SM circuit pack

IO links

The IOhw category includes IOP,HIOP, and HCMIC circuit packs,packlets, ports, and TOD devices.

Type PE, SM, IOP, HIOP,Tape, Disk, RTIF,OC3, CMIC, AMDI,ETHR, TOD

Variable Item type. OC3 is the equivalent ofAMDI.

Loc. < Slot > < Side > <Position > < Devicetype >

Variable Identifies the location of thecomponent, where < Slot > is numericin the range 1 to 18 and < Side > is Ffor front or R for rear. A < Position >value appears only if the component isa packlet or a packlet's port, link, ortime-of-day device. A < Device type >value appears only if the transitionswere by a port, link, or TOD device.

SysB cnts in last Nhrs

Eight numeric values,separated by spaces.Each is an integer inthe range 0 to 15.

Variable The number of SysB transitionsoccurring for the component in thecurrent six-hour interval (the rightmostvalue), and in each of the sevenpreceding six-hour intervals. Thecounter for each interval can count ashigh as 15.

XAC420 173

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 174: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Opt A plus sign (+) or ablank space

Variable A plus sign (+) appears in the Opt fieldif the Group is IOhw, and if the valuein the Sum field is a sum of transitionsfor multiple IOhw components that areassociated with the slot.

Sum Numeric Variable The sum of the SysB transitionsoccurring in the current six-hourinterval, and in the seven precedingsix-hour intervals.

Thresh Two numeric valuesseparated by a slash

Variable The two numeric values separated bya slash indicate the minor and majorSysB transition thresholds for thecomponent.

Sev One asterisk (*), twoasterisks (**), or ablank space

Variable One asterisk indicates that a SysBThminor alarm was raised for thecomponent before the thresholdvalues were reset or changed. Twoasterisks indicate that a SysBTh majoralarm was raised for the componentbefore the threshold values were resetor changed.

Active message exampleXAC420 NOV06 11:33:21 0015 INFO SysBTh Ctrl Changed

Reason: Counters reset from command: CMIC 4 R L

Before counters reset:

Grp Type Component SysB Cnts in last N hrs Sum Thresh

--- ---- --------- 42 36 30 24 18 12 06 00 --- -----

IOhw CMIC 4 R L 0 0 0 0 0 0 0 1 |+ 3 2/6 *

IOlk CMIC 4 R L Link1 0 0 0 0 0 0 0 1 | 1 2/8

IOhw RTIF 4 R U 0 0 0 0 0 0 0 1 |+ 3 2/6 *

IOhw RTIF 4 R U Remote 0 0 0 0 0 0 0 1 |+ 3 2/6 *

XAC420 NOV07 12:43:22 0010 INFO SysBTh Ctrl Changed

Reason: Alarm thresholds changed for: PE

174 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 175: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Old values: minor = 2, major = 7

New values: minor = 2, major = 6

Before threshold change:

Grp Type Component SysB Cnts in last N hrs Sum Thresh

--- ---- --------- 42 36 30 24 18 12 06 00 --- ------

IOlk AMDI 13 R L Link0 1 0 0 0 0 0 0 1 |+ 3 2/8 *

IOhw ETHR 13 R L Port 0 1 0 0 0 0 0 0 |+ 3 2/6 *

Clear message examplen/a

Associated OM registers

XAC600The system generates the Low Shared Memory (LowSM) ConditionCleared log (XAC600) report when the LowSM alarm condition clears andshared memory (SM) redundancy is restored.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

XAC600 175

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 176: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC600 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

176 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 177: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

XAC600 177

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 178: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleXAC600 NOV02 09:23:45 0011 INFO LowSM Condition Cleared

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

SM Insv HOST 01 A00 DPCC:00 00 10F NTLX14CA/nnnnnnnn

Clear message examplen/a

Associated OM registers

• XASMCRIU; XASM

XAC601The system generates the Memory Limit (MemLim) Condition Cleared log(XAC601) report when the low allocatable memory condition clears. Theamount of available memory-store and program-store are above the alarmthresholds.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

DESCRIPTION:<Description Statement>

178 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 179: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC601 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thesystem event.

Active message exampleXAC601 NOV03 15:23:31 0011 INFO MemLim Condition Cleared

DESCRIPTION: Memory usage is now below alarm threshold.

Clear message examplen/a

Associated OM registers

• XASMCRIU; XASM

XAC602The system generates the Low Processor Element (LowPE) ConditionCleared log (XAC602) report when the LowPE alarm condition clears andprocessor element (PE) redundancy is restored.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

XAC602 179

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 180: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possible

180 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 181: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

values for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Reportid XAC602 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

XAC602 181

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 182: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Active message exampleXAC602 MAR22 11:45:43 5700 INFO LowPE Condition Cleared

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

PE Insv HOST 01 A00 DPCC:00 00 16F NTLX02AA/nnnnnnnn

Clear message examplen/a

Associated OM registers

• XAPECRIU; XAPEMAJU; XAPE

XAC603The system generates the MScomm Alarm Cleared log (XAC603) reportwhen the MScomm alarm condition clears. Communication between theXA-Core and the Message Switch (MS) is restored. CMIC link redundancyis restored.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

182 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 183: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC603 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction with

XAC603 183

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 184: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

the Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the CMIC links are supported byOC-3 two port interface packlets, thisis a character identifying the packletposition (upper or lower). Possiblevalues are U and L. If the links aresupported by HCMIC circuit packs, thefield is blank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

184 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 185: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC603 OCT27 15:47:38 7500 INFO MScomm Alarm Cleared

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

CMIC Insv HOST 01 A00 DPCC:00 00 15R L NTLX05AA/nnnnnnnn

Clear message examplen/a

Associated OM registers

• XCMICLNK; XCMICPRT; XCMIC; XALKMAJU

XAC604The system generates the (Time-of-Day) TOD Alarm Cleared log(XAC604) report when the TOD alarm condition clears. All TOD clocks onthe MS and XA-Core are in-service.

Event type: Information (INFO)

Remedial actionn/a

XAC604 185

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 186: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC604 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

186 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 187: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the TOD devices are on OC-3 twoport interface packlets, this is acharacter identifying the packletposition (upper or lower). Possiblevalues are U and L. If the TODdevices are on HCMIC circuit packs,the field is blank.

XAC604 187

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 188: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC604 NOV27 15:48:37 1900 INFO TOD Alarm Cleared

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

TOD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

CMIC Insv HOST 00 A00 DPCC:00 00 05R L 0 NTLX05AA/nnnnnnnn

Clear message examplen/a

Associated OM registers

• XCMICLNK; XCMICPRT; XCMIC

XAC605The system generates the Reset Terminal Interface (RTIF) Alarm Clearedlog (XAC605) report when the RTIF alarm condition clears. All local andremote ports on HCMIC circuit packs or on RTIF packlets are in-service.

Event type: Information (INFO)

188 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 189: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC605 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,

XAC605 189

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 190: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the RTIF links are supported byRTIF packlets, this is a characteridentifying the packlet position (upper

190 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 191: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

or lower). Possible values are U andL. If the RTIF links are supported byHCMIC circuit packs, the field is blank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC605 NOV09 13:38:01 4500 INFO RTIF Alarm Cleared

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

PORT: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

RTIF Insv HOST 01 A00 DPCC:00 00 04R U 0 NTLX08AA/nnnnnnnn

Clear message examplen/a

Associated OM registers

• XAIOP; XRTIFLNK; XRTIFPRT; XRTIF

XAC605 191

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 192: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

XAC606The system generates the Disk Alarm Cleared log (XAC606) report when aDisk packlet alarm condition clears, and the Disk packlet returns-to-service.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC606 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

192 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 193: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possible

XAC606 193

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 194: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

values for the slot are in the range 1 to18. Possible values for the side are Fand R.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC606 MAR02 09:23:19 6600 INFO Disk Alarm Cleared

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

DISK Insv HOST 01 A00 DPCC:00 00 17F L NTLX06AA/nnnnnnnn

Clear message examplen/a

194 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 195: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

• XADISK;

XAC607The system generates the Tape Alarm Cleared log (XAC607) report whena Tape alarm condition clears, and the Tape packlet returns-to-service(RTS).

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC607 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

XAC607 195

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 196: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

196 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 197: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC607 MAR01 11:21:32 6400 INFO Tape Alarm Cleared

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

Tape Insv HOST 01 A00 DPCC:00 00 17F U NTLX07AA/nnnnnnnn

XAC607 197

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 198: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

• XATAPE;

XAC608The system generates the Image Alarm Cleared log (XAC608) report whenan XA-Core image test passes, or when an Image Test (ImgTst) Alarmcondition clears.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ssssdd Event TypeEvent Text

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC608 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Test Passed or AlarmCleared

Variable The Event Text field indicates whenan XA-Core image test passes, orwhen an Image Test (ImgTst) alarmcondition clears.

Active message exampleXAC608 MAR06 8:26:49 6400 INFO Image (Test Passed/AlarmCleared)

Clear message examplen/a

198 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 199: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

XAC609The system generates the AMDI Link Condition Cleared log (XAC609)report when out of service (OOS) AMDI links are returned to service andthe AMDI alarm is clear.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC609 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

XAC609 199

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 200: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

200 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 201: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the AMDI links are supported by anAMDI packlet, this is a characteridentifying the packlet position (upperor lower). Possible values are U andL. If the AMDI links are supported byan HIOP circuit pack, the field isblank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC609 FEB27 11:02:45 6300 INFO AMDI (AMDI Link ConditionCleared)

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

LINK: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

AMDI Insv HOST 00 A00 DPCC:00 00 04R L 0 NTLX05BA/nnnnnnnn

XAC609 201

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 202: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

XAC610The Card Returned to Service log reports a return-to-service (RTS) statechange of a circuit pack (CP) or packlet when both of the followingconditions occur:

A circuit pack (CP) or packlet returns to service.

The RTS state change of this CP or packlet is not connected to an alarmclearing condition.

A Card Returned to Service log indicates a Minor alarm condition. A Minoralarm condition means that a CP or packlet has returned to service.

The Card Returned to Service log does not generate for all RTS statechanges of a CP or packlet. If a CP or packlet returns to service because arelated alarm condition clears, the log connected with this alarm clearingcondition reports the RTS state change. For example, if a Shared MemoryCP returns to service because a LowSM alarm condition clears, theLowSM Condition Cleared log report generates and reports that the SM CPis now in-service. In this example, the Card Returned to Service log reportdoes not report the RTS state change.

Event type: Return to Service (RTS)

Remedial actionIf the IMPACT field indicates that PE upgrade activity is in progress andthat the Config alarm is raised, the craftsperson should complete theupgrade process by replacing the remaining earlier-model PE circuit packswith NTLX02DA-model PE circuit packs.

AttributesAttribute Value

Severity Minor

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

202 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 203: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

IMPACT:<System Impact Statement>

ACTION:<Action Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC610 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type RTS Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resource

XAC610 203

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 204: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

involved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the component that returned toservice is a packlet or a device on apacklet, this is a character identifyingthe packlet position (upper or lower).Possible values are U and L.Otherwise the field is blank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

204 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 205: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

IMPACT Text string (optional) Variable The Impact field describes the impactof the condition to the XA-Core.

ACTION Text string (optional) Variable The Action field displays therecommended action that operatingcompany personnel can follow in lightof the information in the IMPACT field.

Active message exampleXAC610 FEB27 11:02:45 6300 RTS Returned to Service

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

PE Insv HOST 01 A00 DPCC:00 00 05F NTLX02CA/nnnnnnnn

IMPACT: PE upgrade activity in progress. Config alarm israised.

ACTION: Upgrade remaining processor cards.

Clear message examplen/a

XAC610 205

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 206: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

XAC612The system generates the input/output processor (IOP) Alarm Cleared log(XAC612) report when an IOP alarm condition clears, and the IOP, HIOP,or HCMIC circuit pack (CP) returns to service (RTS).

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC612 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

206 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 207: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

XAC612 207

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 208: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC612 MAY18 11:15:39 6000 INFO IOP Cleared

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

IOP Insv HOST 01 A00 DPCC:00 01 17F NTLX03AA/nnnnnnnn

Clear message examplen/a

208 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 209: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

• XAIOP;

XAC613The system generates the RExSch Alarm Cleared log (XAC613) reportwhen the RExSch (REx Schedule Failure) alarm condition clears. TheRExSch (REx Schedule Failure) alarm condition clears when a systeminitiated daily REx test (SREx) runs to completion and passes.

Event type: Summary (SUMM)

Remedial actionn/a

AttributesAttribute Value

Severity Minor

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

DESCRIPTION:<Description Statement>

<Severity of alarm condition cleared statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC613 Variable The Reportid field displays the loggroup and identification number in thelog report.

Event Type SUMM Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thesystem event and indicates theseverity of the alarm conditioncleared.

Active message exampleXAC613 June 1 16:45:30 4500 SUMM RExSch Alarm Cleared

XAC613 209

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 210: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DESCRIPTION:REx Schedule alarm condition cleared.

Minor alarm condition cleared.

Clear message examplen/a

Associated OM registers

XAC614The system generates the XATrap Alarm Cleared log (XAC614) reportwhen the XATRAP alarm condition clears. The XATRAP alarm conditionclears when the trap rate (number of traps per minute) on the XA-Core fallsbelow the XATRAP alarm threshold.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Title text

DESCRIPTION:<Description Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC614 Variable The Reportid field displays the loggroup (XAC) and identification numberin the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thesystem event.

210 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 211: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleXAC614 JAN01 14:56:13 0011 INFO XATrap Alarm Cleared

DESCRIPTION: Trap rate has dropped below XATRAP alarmthreshold.

Clear message examplen/a

Associated OM registers

• XATRAP;

XAC615The system performs a system routine exercise (SREx) test, or operatingcompany personnel perform a manual REx test to make sure that XA-Corehardware is functioning correctly.

The system generates the REx Started log (XAC615) report when a routineexercise (REx) test begins on the XA-Core.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

DESCRIPTION:<Description Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC615 Variable The Reportid field displays the loggroup and identification number in thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

XAC615 211

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 212: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thesystem event.

Active message exampleXAC615 NOV02 09:23:56 0011 INFO REx Started

DESCRIPTION: XA-Core REx has been initiated.

Clear message examplen/a

Associated OM registers

• XARSMPXU;

XAC618When the XA-Core enters split mode, the system generates the Split ModeEntered log (XAC 618) report. When the XA-Core system is in split mode,there is an upgrade to the operating system software in progress.Maintenance software has configured processor and shared memory toallow two images to run at the same time. One part of the XA-Core switchcontinues to process call traffic. The remaining part of the system is readyto receive, or is receiving new operating software.

The Split (Split Mode Entered) log report identifies the shared memory(SM) and processor element (PE) circuit packs (CP) that are not availablefor call processing while the XA-Core is in split mode.

A Split (Split Mode Entered) log report indicates a Minor alarm. A Minoralarm means that the XA-Core system has entered split mode.

When the XA-Core exits split mode, the system generates the Split ModeExited log (XAC619) report.

Event type: Information (INFO)

Remedial actionn/a

212 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 213: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Minor

• Warning

FormatSeverity XACnnn mmmdd hh:mm:ssssdd Event Type Event Text

DESCRIPTION:<Description Statement>

TYPE Slot

____ ____

<cc><nnc>

<cc><nnc>

REASON:<Reason Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Slot Character string Variable The Slot field displays the shelf slotposition of CP that is not available forcall processing while the XA-Core is insplit mode.

REASON Text string Variable The Reason field identifies the reasonwhy the PE and SM CPs are notavailable for call processing.

Severity one asterisk (*) Variable Displays the severity of the associatedalarm.

One asterisk (*) indicates a minoralarm condition. The XA-Core systemhas entered split mode.

Reportid XAC618 Variable The Reportid field displays the loggroup (XAC) and identification numberin the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

XAC618 213

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 214: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DESCRIPTION Text string Variable The Description field describes thesystem event. This field also identifiesthe type and slot position of the circuitpacks (CPs) that are not available forcall processing while the XA-Core is insplit mode.

Type SM, PE Variable The Type field displays the type ofcircuit pack (CP) that is not availablefor call processing while the XA-Coreis in split mode.

Active message example* XAC618 DEC11 16:06:39 1600 INFO Split (Split Mode Entered)

DESCRIPTION: XA-Core has entered Split Mode. Some SM

and PE cards are unavailable for call

processing. The following cards are affected:

TYPE Slot

---- ----

PE 04F

SM 08F

REASON: System Maintenance

Clear message examplen/a

Associated OM registers

• XARSMPXU; XAMSMPXU; XASSMPXU; XAPEMAJU

XAC619The system generates the Split Mode Exited (XAC619) log report when theXA-Core switch exits split mode. All processor element (PE) and SharedMemory (SM) circuit packs (CP) are now available to run a single softwareimage.

Event type: Information (INFO)

214 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 215: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

DESCRIPTION:<Description Statement>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC619 Variable The Reportid field displays the loggroup and identification number in thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thesystem event.

Active message exampleXAC619 MAY14 13:56:34 0011 INFO Split Mode Exited

DESCRIPTION:XA-Core is no longer in Split Mode.

Clear message examplen/a

Associated OM registers

• XARSMPXU; XAMSMPXU; XASSMPXU; XAPEMAJU

XAC620The system generates the SysBTh Alarm Cleared log report when it clearsa SysBTh minor or major alarm.

XAC620 215

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 216: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

See the description of log XAC320 in this chapter for a list of thecomponents for which the system maintains counts of system-busy (SysB)transitions, and for a description of the conditions in which the systemraises SysBTh minor and SysBTh major alarms.

Remedial actionn/a

AttributesAttribute Value

Severity • Major

• Minor

• Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

Reason:<Reason Statement>

Grp Type Component SysB Cnts in last N hrs Sum Thresh

--- ---- --------- 42 36 30 24 18 12 06 00 --- ------

<Group><Type><Loc.>nn nn nn nn nn nn nn nn |<Opt>nn<nn/nn><Sev>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC620 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

Reason "Minor alarm cleared."or "Major alarmcleared."

Variable Identifies the type of alarm thatcleared.

216 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 217: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Group PE SM IOlk IOhw Variable PE circuit pack or SM circuit pack orIO links or IO hardware. The IOhardware category includes IOP,HIOP, and HCMIC circuit packs,packlets, ports, and TOD devices.

Type PE, SM, IOP, HIOP,Tape, Disk, RTIF,OC3, CMIC, AMDI,ETHR, TOD

Variable Item type. OC3 is the equivalent ofAMDI.

Loc. < Slot > < Side > <Position > < Devicetype >

Variable Identifies the location of thecomponent, where < Slot > is numericin the range 1 to 18 and < Side > is Ffor front or R for rear. A < Position >value appears only if the component isa packlet or a packlet's port, link, ortime-of-day device. A < Device type >value appears only if the transitionswere by a port, link, or TOD device.

SysB cnts in last Nhrs

Eight numeric values,separated by spaces.Each is an integer inthe range 0 to 15.

Variable The number of SysB transitionsoccurring for the component in thecurrent six-hour interval (the rightmostvalue), and in each of the sevenpreceding six-hour intervals. Thecounter for each interval can count ashigh as 15.

Opt A plus sign (+) or ablank space

Variable A plus sign (+) appears if the Group isIOhw, and if the value in the Sum fieldis a sum of transitions for multipleIOhw components that are associatedwith the slot.

Sum Numeric Variable The sum of the SysB transitionsoccurring in the current 6-hourinterval, and in the seven preceding 6-hour intervals.

Thresh Two numeric valuesseparated by a slash

Variable The two values separated by a slashindicate the minor and major SysBtransition thresholds for thecomponent.

Sev One asterisk (*), twoasterisks (**), or ablank space

Variable One asterisk indicates that a SysBThminor alarm is raised. Two asterisksindicate that a SysBTh major alarm israised.

XAC620 217

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 218: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleXAC620 NOV02 20:00:01 0019 INFO SysBTh Alarm Cleared

Reason: Minor alarm cleared.

Grp Type Component SysB Cnts in last N hrs Sum Thresh

--- ---- --------- 42 36 30 24 18 12 06 00 | --- ------

IOhw TOD 15 F L TOD 0 0 1 0 0 0 0 0 | 1 2/6

Clear message examplen/a

Associated OM registers

XAC622The system generates the Processor Element Trouble (PETrbl) AlarmCleared log (XAC622) report when the PETrbl alarm condition clears. ThePETrbl alarm condition clears when a non-critical fault on a processorelement (PE) circuit pack (CP) clears. The clearing of the non-critical faultcauses the PE CP to change state from IsTb to InSv.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity • Critical

• Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

218 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 219: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC622 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

XAC622 219

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 220: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

220 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 221: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleXAC622 NOV09 09:23:45 0011 INFO PETrbl Alarm Cleared

DESCRIPTION: State has changed from ISTB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

PE Insv HOST 01 A00 DPCC:00 00 04F NTLX02AA/nnnnnnnn

Clear message examplen/a

Associated OM registers

XAC623The system generates the Shared Memory Trouble (SMTrbl) AlarmCleared (XAC623) log report when the SMTrbl alarm condition clears. AnSMTrbl alarm clears when a non-critical fault condition on a sharedmemory (SM) circuit pack (CP) clears. The clearing of the non-critical faultcauses the SM CP to change state from IsTb to InSv.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity • Critical

• Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

XAC623 221

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 222: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC623 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

222 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 223: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

XAC623 223

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 224: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleXAC623 DEC12 11:51:03 7600 INFO SMTrbl Alarm Cleared

DESCRIPTION: State has changed from ISTB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

SM Insv HOST 00 A00 DPCC:00 00 11F NTLX14CA/nnnnnnnn

Clear message examplen/a

Associated OM registers

XAC624The system generates the input/output Trouble (IOTrbl) Alarm Cleared(XAC624) log report when an IOTrbl alarm condition clears. An IOTrblalarm clears when a non-critical fault condition clears on any of thefollowing elements and that element changes state from IsTb to InSv:

high performance input/output processor (HIOP) circuit pack (CP)

high performance CMIC (HCMIC) circuit pack (CP)

input/output processor (IOP) circuit pack (CP)

IOP packlet (RTIF, CMIC, Disk or Tape packlet)

a link, port, or TOD clock

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity • Critical

• Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

224 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 225: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

XAC624 225

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 226: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the component on which the troublecondition cleared was a packlet or adevice on a packlet, this is a characteridentifying the packlet position (upperor lower). Possible values are U andL. Otherwise the field is blank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

226 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 227: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Reportid XAC624 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

Active message exampleXAC624 JAN09 09:42:23 9000 INFO IOTrbl Alarm Cleared

DESCRIPTION: State has changed from ISTB to INSV by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

IOP Insv HOST 00 A00 DPCC:00 01 17F NTLX03AA/nnnnnnnn

Clear message examplen/a

Associated OM registers

XAC625A retrofit inactive boot key (RIBkey) is a tool that Installation personnel useduring an upgrade or cutover process of the XA-Core. A RIBkey connectsto the local port on each of the XA-Core reset terminal interfaces (RTIF).Installation personnel remove the RIBKeys when the switch of activity(SWact) is complete and the XA-Core is the active core.

The system generates the RIBKEY Removed log (XAC625) report toindicate to operating company personnel when a RIBKEY device isremoved from a local RTIF port on an RTIF packlet or on an HCMIC circuitpack.

Event type: Information (INFO)

Remedial actionn/a

XAC625 227

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 228: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity • Warning

• Minor

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

DESCRIPTION:<Description Statement>

<Severity of alarm condition cleared statement>

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn/nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC625 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thesystem event and indicates the alarmseverity of the condition cleared.

CARD Type Character string Variable The Card Type field displays the typeof circuit pack (CP) or packletidentified in the log report.

State Character string Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site Character string Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

FL Numeric Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

228 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 229: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Row Alphanumeric Variable The Row field displays the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay Alphanumeric Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shf/Slot Alphanumeric nn/nnsp nn/ =0 to 3 /nn =01to 18 s =F or R p =Uor L

Variable The Shelf (Shf) and Slot field identifythe shelf position within the bay, andslot position within the shelf, thatcontains the CP or packlet identified inthe log report.

nn/ = the shelf position number. /nn =the slot position number. s = sideposition, either the front (F) side orrear (R) side of the XA-Core shelf thatcontains the CP. p = the packletposition, either the upper (U) or lower(L) position, within an IOP CP. Thepacklet position only displays whenthe indicated slot and side are from anIOP.

EqPEC/Serial Alphanumeric Variable The EqPEC/Serial field identifies theequipment product engineering code(EqPEC) and the serial number of theCP or packlet identified in the logreport.

Active message exampleXAC625 NOV06 12:09:18 0011 INFO RIBKEY Removed

DESCRIPTION:A RIBKEY has been removed from the XA-Core.

Minor alarm condition cleared.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

RTIF InSv HOST 00 A00 DPCC:00 01/15F U NTLX08AA/nnnnnnnn

Clear message examplen/a

XAC625 229

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 230: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

XAC626A message switch (MS) Link mismatch occurs when a CMIC link from aport on the CMIC hardware in the XA-Core shelf (an HCMIC circuit pack oran XA-Core OC-3 two-port Interface packlet) is connected to the wrongport on the MS OC-3 2-port Interface Paddleboard.

The switch generates the MS Link Mismatch Configuration Restored(XAC626) log report when the XA-Core CMIC port to MS port linkconnections are restored to the correct configuration.

Event type: Information(INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Event Text

DESCRIPTION:<Description Statement>

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn/nns p ccccnncc/nnnnnnnnn

PORT: n

SHELF MS CARD PORT

EXPECTED: nn nn nn nn

ACTUAL: nn nn nn nn

230 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 231: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC626 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thesystem event.

CARD Type Character string Variable The Card Type field displays the typeof circuit pack (CP) or packletidentified in the log report.

State Character string Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site HOST Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

FL Numeric Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shf/Slot nn/nns p nn/ = 0 to 3 /nn =01 to 18 s =F orR p =U or L

Variable The Shelf (Shf) and Slot field identifythe shelf position within the bay, andslot position within the shelf, thatcontains the CP or packlet identified inthe log report.

nn/ = the shelf position number. /nn =the slot position number. s = sideposition, either the front (F) side orrear (R) side of the XA-Core shelf thatcontains the CP. p = the packletposition, either the upper (U) or lower

XAC626 231

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 232: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

(L) position, within an IOP CP. Thepacklet position only displays whenthe indicated slot and side are from anIOP CP.

EqPEC/Serial Alphanumeric Variable The EqPEC/Serial field identifies theequipment product engineering code(EqPEC) and the serial number of theCP or packlet identified in the logreport.

PORT 0 to 1 Variable The Port field indicates the portnumber on a CMIC packlet.

REASON Text string Variable The Reason field describes the causeof the condition reported in the logreport.

EXPECTED Character string Variable The Expected field indicates theexpected MS Link configuration.

This field identifies the expected MSshelf number, MS, MS Card numberand MS port number.

ACTUAL Character string Variable The Actual field indicates the actualMS Link configuration.

This field identifies the actual MS shelfnumber, MS, MS Card number andMS port number.

Active message exampleXAC626 NOV03 18:34:45 8800 INFO MS Link ConfigurationRestored

DESCRIPTION:MS Link Configuration has been restored.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

CMIC InSv HOST 00 A00 DPCC:00 01/15R L NTLX05AA/nnnnnnnnn

PORT: 0

SHELF MS CARD PORT

EXPECTED: 0 1 24 0

ACTUAL: 0 1 24 0

232 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 233: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

XAC627The system generates the WgSlot Cleared (Card Removed) log (XAC627)report when a WgSlot alarm condition clears. A WgSlot alarm conditionclears when operating company personnel remove a circuit pack (CP) fromthe wrong XA-Core shelf slot.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Title text

DESCRIPTION:<Description Statement>

Shf Slot Side TypePEC

nn nn c cc ccccnncc

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC627 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Event Text Text string Variable The Event Text field describes thetype of event identified in the logreport.

DESCRIPTION Text string Variable The Description field describes thesystem event.

XAC627 233

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 234: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Shf Numeric Variable The Shf field indicates the shelfposition of the circuit pack (CP) thatwas removed from the wrong shelfslot.

Slot Numeric Variable The Slot field describes the shelf slotposition of the CP that was removedfrom the wrong shelf slot.

Side F or R Variable The Side field indicates the shelf sidelocation of the CP that was removedfrom the wrong shelf slot. The sidelocation can be the front (F) side orrear (R) side of the shelf.

Type Character string Variable The Type field indicates the type ofCP that was removed from the wrongshelf slot.

PEC Alphanumeric Variable The PEC field indicates the PECnumber of the CP that was removedfrom the wrong shelf slot.

Active message exampleXAC627 NOV02 13:45:56 1700 INFO WgSlot Cleared - CardRemoved

DESCRIPTION:Card in wrong slot removed.

Shf Slot Side TypePEC

00 06 F PE NTLX02AA

Clear message examplen/a

Associated OM registers

XAC628The system generates the XA-Core Provisioning/Deprovisioning log(XAC628) when a component on the XA-Core is provisioned ordeprovisioned.

Event type: Information (INFO)

Remedial actionNo immediate action.

234 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 235: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

XAC628 235

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 236: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable A character identifying the packletposition (upper or lower). Possiblevalues are U and L.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Reportid XAC628 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO or UPGRADE Variable The Event Type field displays the typeof event identified in the log report.UPGRADE indicates that a PE circuitpack was provisioned ordeprovisioned during the process ofupgrading from earlier-model PEcircuit packs to NTLX02DA models.

Log title Text string Variable A text string describing the title of thelog report.

236 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 237: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Active message exampleXAC628 FEB14 17:50:32 3000 INFO XA-Core Provisioning Report

DESCRIPTION: State has changed from UNEQ to SYSB by SYSTEMaction

CARD: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

SM SysB HOST 01 A00 DPCC:00 00 09F NTLX14CA/nnnnnnnn

Clear message examplen/a

Associated OM registers

XAC629The system generates the Ethernet Link Condition Cleared log (XAC629)report when the ETHR alarm condition clears.

Event type: Information (INFO)

XAC629 237

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 238: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION: State has changed from OldState to NewState byInit. action

Class: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

cccc cccc cccc nn cnn cccc:nn nn nns p ccccnncc/nnnnnnnn

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC629 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable A text string describing the statechange. The DESCRIPTION fieldcontains the following fields: OldState, New State, and Initiator.

OldState 4 characters Variable A character field identifying the "from"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

NewState 4 characters Variable A character field identifying the "to"state. Possible values are: SYSB,CBSY, MBSY, ISTB, INSV, UNEQ,and SPLT.

Initiator (Init) Up to 12 characters Variable A character field identifying theinitiator of the state change. Possiblevalues are: MANUAL, SYSTEM,RECOVERY, PROVISIONING,

238 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 239: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

CLOCKEVENT, FAULT, SWACT,REX, IMGTST, MSMTCE, SREX,AUDIT, IRM, and CCMT.

Class 4 characters Variable The class of resource that is involvedin the state change. Possible valuesare: CARD, PORT, LINK, and TOD.

Type 4 characters Variable A character field identifying the type ofCP or packlet identified in the logreport. This field, in conjunction withthe Class field, identifies the resourceinvolved in the state change. Forexample, Class Link and Type ETHRidentifies an Ethernet link.

State 4 characters Variable The State field displays the currentoperational state of the CP or packletidentified in the log report.

Site 4 characters Variable The Site field displays the site locationof the switch that contains the CP orpacklet identified in the log report.

Floor 2 digits Variable The Floor field displays the floorposition, within the site, of the CP orpacklet identified in the log report.

Row Alphanumeric: 1 digitfollowed by 2characters

Variable The Row field identifies the rowposition, on the floor, that contains theCP or packlet identified in the logreport.

Bay DPCC:00 Variable The Bay field identifies the bay (frametype and number) that contains theCP or packlet identified in the logreport.

Shelf 2 digits Variable A number identifying the shelf wherethe CP, packlet, or device is located.Possible values are 0, 1, 2, and 3.

Slot 3 alphanumericcharacters

Variable Two digits identifying the slot numberand one character identifying the side(front or rear) of the shelf. Possiblevalues for the slot are in the range 1 to18. Possible values for the side are Fand R.

Packlet 1 character (optional) Variable If the ethernet links are supported byethernet packlets, this is a characteridentifying the packlet position (upperor lower). Possible values are U and

XAC629 239

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 240: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

L. If the links are supported by HIOPor HCMIC circuit packs, the field isblank.

Device 1 digit (optional) Variable One digit identifying the number of thedevice (0 or 1) involved in the statechange. This field is displayed only ifthe Class of the resource involved inthe state change is PORT, LINK, orTOD.

EqPEC 9 alphanumericcharacters

Variable The EqPEC field identifies the productengineering code (EqPEC) of the CPor packlet identified in the log report. Ifthe device involved in the statechange is not a CP or packlet, thenthe EqPEC displayed is that of the CPor packlet that is hosting the device.

Serial 14 alphanumericcharacters

Variable The Serial field identifies the serialnumber of the CP or packlet identifiedin the log report. If the device involvedin the state change is not a CP orpacklet, then the serial numberdisplayed is that of the CP or packletthat is hosting the device.

Active message exampleXAC629 OCT09 19:09:19 1900 INFO ETHR (Ethernet LinkCondition Cleared)

DESCRIPTION: State has changed from SYSB to INSV by SYSTEMaction

LINK: Type State Site FL Row Bay Shf/Slt/Pk EqPEC/Serial

ETHR Insv HOST 00 A00 DPCC:00 00 05R L 0 NTLXO9AA/nnnnnnnn

Clear message examplen/a

Associated OM registers

XAC630The system generates this log when the firmware (FW) mismatch clears.The mismatch occurs when FW version on the field replaceable unit (FRU)and the FW version in the XAFWLOAD data schema table does not match.

240 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 241: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Tide

DESCRIPTION:<Description statement>

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

<FRU><state><location><shelf>/<slot><side><PEC>/<#>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC630 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable Provides details.

< FRU > character string Variable Indicates the FRU type is PE, HIOP,IOP, CMIC, ETHR, or AMDI.

< state > character string Variable Indicates the FRU state is InSv, SysB,ManB, CBsy or ISTb.

< location > character string Variable Indicates the location of XA-Core.

< shelf > integer Variable Indicates the shelf number is 0, 1, 2 or3.

< slot > integer Variable Indicates the slot number is 2 to 17.

< side > character string Variable Indicates the slot side is front or rear.

< PEC > alphanumeric Variable FRU product engineering codeNTLXxxxx in format.

XAC630 241

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 242: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

< # > numeric Variable Indicates the FRU serial number.

< FW version > character string Variable Indicates newly loaded FW versioncomprised of 8 characters.

Active message exampleXAC630 OCT27 18:29:47 8300 INFO No FW version mismatch

DESCRIPTION: FW version is XAIO1AG.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

IOP InSv HOST 01 A00 DPCC:00 00/17F NTLX03BA/Not avail

Clear message examplen/a

Associated OM registers

XAC631The system generates the log XAC631 when the firmware (FW) soakingprocess begins.

A Firmware Soaking Started log report indicates an FWsoak Minor alarm.This alarm indicates that firmware soaking is in progress.

Event type: Information (INFO)

Soaking starts when the FRU is returned to service for the first time afterloading firmware.

Remedial actionn/a

AttributesAttribute Value

Severity • Minor

• Warning

FormatXAC631 mmmdd hh:mm:ss ssdd INFO FW soaking started

242 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 243: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

DESCRIPTION: Soaking of FW started.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

<FRU><state><location><shelf>/<slot><side><PEC>/<#>

Selected field descriptionsField Value Fixed or

VariableDescription

< FRU > character string Variable Indicates the FRU type is PE, HIOP,IOP CMIC, ETHR, or AMDI.

< state > character string Variable Indicates the FRU state is InSv, SysB,ManB, CBsy or ISTb.

< location > character string Variable Indicates the location of XA-Core.

< shelf > integer Variable Indicates the shelf number is 0, 1, 2 or3..

< slot > integer Variable Indicates the slot number is 2 to 17.

< side > character string Variable Indicates the slot side is front or rear.

< PEC > alphanumeric Variable FRU product engineering codeNTLXxxxx in format.

< # > numeric Variable Indicates the FRU serial number.

Active message exampleXAC631 OCT27 17:54:09 6100 INFO FW soaking started

DESCRIPTION: Soaking of FW started.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

PE InSv HOST 01 A00 DPCC:00 00/04F NTLX02AA/Not avai

Clear message examplen/a

Associated OM registers

XAC632The system generates the log XAC632 when the firmware (FW) soakingprocess completes.

Event type: Information (INFO)

XAC632 243

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 244: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionIf the number of faults is zero, do not take action.

If there are any faults, check the fault records to verify that the newfirmware is not the cause of the faults. If the new firmware is causing thefaults, revert to the original firmware.

AttributesAttribute Value

Severity • Warning

• Critical

FormatXAC632 mmmdd hh:mm:ss ssdd INFO FW soaking completed

DESCRIPTION: Soaking of FW is complete (<#h>hours).

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

<FRU><state><location><shelf>/<slot><side><PEC>/<#>

Number of critical faults encountered:<n>

Fault Record Id:

=============================================

<#### ####>

<#### ####>

<#### ####>

<#### ####>

<#### ####>

==============================================

244 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 245: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

< #h > integer Variable Indicates the total number of hourssoaked from 0 to 240 hours.

< FRU > character string Variable Indicates the FRU type is PE, HIOP,IOP, CMIC, ETHR, or AMDI.

< state > character string Variable Indicates the FRU state is InSv, SysB,ManB, CBsy or ISTb.

< location > character string Variable Indicates the location of XA-Core.

< shelf > integer Variable Indicates the shelf number is 0, 1, 2 or3.

< slot > integer Variable Indicates the slot number is 2 to 17.

< side > character string Variable Indicates the slot side is front or rear.

< PEC > alphanumeric Variable FRU product engineering codeNTLXxxxx in format.

< # > numeric Variable Indicates the FRU serial number.

< #### #### > alphanumeric Variable Indicates the fault record identifier.

Active message exampleXAC632 OCT26 21:06:27 8200 INFO FW soaking completed

DESCRIPTION: Soaking of FW is complete (48 hours).

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

IOP InSv HOST 01 A00 DPCC:00 00/02F NTLX03BA/Not/avail

Number of critical faults encountered: 1

Fault Record Id:

=============================================

05A2 6000

=============================================

Clear message examplen/a

XAC632 245

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 246: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

XAC633The system generates log XAC633 when the firmware (FW) loadingprocess begins.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION:<Description statement>

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

<FRU><state><location><shelf><slot><side><PEC>/<#>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC633 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable Provides details..

< FRU > character string Variable Indicates the FRU type is PE, HIOP,IOP, CMIC, ETHR, or AMDI.

< state > character string Variable Indicates the FRU state is InSv, SysB,ManB, CBsy or ISTb.

< location > character string Variable Indicates the location of XA-Core.

< shelf > integer Variable Indicates the shelf number is 0, 1, 2 or3.

246 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 247: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

< slot > integer Variable Indicates the slot number is 2 to 17.

< side > character string Variable Indicates the slot side is front or rear.

< PEC > alphanumeric Variable FRU product engineering codeNTLXxxxx in format.

< # > alphanumeric Variable Indicates the FRU serial number.

Active message exampleXAC633 OCT27 17:53:59 5900 INFO FW loading started

DESCRIPTION: Loading of FW started.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

PE ManB HOST 01 A000 DPC:00 00 04F NTLX02AA/Not avai

Clear message examplen/a

Associated OM registers

XAC634The system generates the log XAC634 when the firmware (FW) loadingprocess completes successfully.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION:<Description statement>

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

<FRU><state><location><shelf><slot><side><PEC>/<#>

XAC634 247

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 248: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC634 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable Provides details.

< FRU > character string Variable Indicates the FRU type is PE, HIOP,IOP, CMIC, ETHR, or AMDI.

< state > character string Variable Indicates the FRU state is InSv, SysB,ManB, CBsy or ISTb.

< location > character string Variable Indicates the location of XA-Core.

< shelf > integer Variable Indicates the shelf number is 0, 1, 2 or3.

< slot > integer Variable Indicates the slot number is 2 to 17.

< side > character string Variable Indicates the slot side is front or rear.

< PEC > alphanumeric Variable FRU product engineering codeNTLXxxxx in format.

< # > numeric Variable Indicates the FRU serial number.

Active message exampleXAC634 OCT27 17:53:59 6000 INFO FW loading completed

DESCRIPTION: Loading of FW has been completed.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

PE ManB HOST 01 A00 DPCC:00 00 04F NTLX02AA/Not avail

Clear message examplen/a

Associated OM registers

XAC635The system generates log XAC635 after a restart if a field replaceable unit(FRU) is in the soaking state.

248 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 249: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

A Firmware Soaking in Progress log report indicates an FWsoak Minoralarm. This alarm indicates that firmware soaking is in progress.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity • Minor

• Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

DESCRIPTION:<Description statement>

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

<FRU><state><location><shelf>/<slot><side><PEC>/<#>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC635 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

DESCRIPTION Text string Variable Provides details.

< FRU > character string Variable Indicates the FRU type is PE, HIOP,IOP, CMIC, ETHR, or AMDI.

< state > character string Variable Indicates the FRU state is InSv, SysB,ManB, CBsy or ISTb.

< location > character string Variable Indicates the location of XA-Core.

< shelf > integer Variable Indicates the shelf number is 0, 1, 2 or3.

< slot > integer Variable Indicates the slot number is 2 to 17.

XAC635 249

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 250: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

< side > character string Variable Indicates the slot side is front or rear.

< PEC > alphanumeric Variable FRU product engineering codeNTLXxxxx in format.

< # > numeric Variable Indicates the FRU serial number.

Active message exampleXAC635 OCT27 17:07:40 1900 INFO FW soaking in progress

DESCRIPTION: Soaking of FW is in progress.

CARD: Type State Site FL Row Bay Shf/Slot EqPEC/Serial

IOP SysB HOST 01 A00 DPCC:00 00/02F NTLX03BA/Not avai

Clear message examplen/a

Associated OM registers

XAC637The system generates the Baseln Alarm Cleared log report when theBaseln major alarm clears, indicating that there are no longer any items ofhardware or firmware that are incompatible with the baseline and exceptionlist information in tables PECINV and FWINV.

Event type: Information (INFO)

Remedial actionn/a

AttributesAttribute Value

Severity • Major

• Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

All XAC HW at PECINV baseline. All XAC FW/DLL at FWINVbaseline.

250 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 251: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC637 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string:BaselineAlarm Cleared"

Variable A text string describing the title of thelog report.

Active message exampleXASKY07GH XAC637 JAN15 23:35:16 6100 INFO Baseln AlarmCleared

All XAC HW at PECINV baseline. All XAC FW/DLL at FWINVbaseline.

Clear message examplen/a

Associated OM registers

XAC640The system generates the Manual Test Report log (XAC640) for thefollowing reasons:

record the results of a manual test request on an XA-Core component

record the results of a system test request initiated when a new card orpacklet is provisioned to a manbusy state.

Event type: Information (INFO)

Remedial actionNo immediate action.

AttributesAttribute Value

Severity Warning

FormatXACnnn nimnidd hh:mm:ss ssdd Event Type Log Title

XAC640 251

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 252: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

TYPE Link_Num Slot Side Packlet Test_Type Result

tttt n nn fifr p test_txt result_txt

Initiator: intiator_text

Reason: reason_txt

FAULT RECORD ID: id

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC640 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

Variable

tttt character string Variable Indicates the type of circuit pack (CP),packlet, or link.

n numeric Variable Indicates the link number.

This field can indicate link 0, link 1, orremain blank.

This field remains blank if operatingcompany personnel do not perform amanual test on a link.

nn alphanumeric Variable Indicates slot position of the device.

frfr alphanumeric Variable Indicates the shelf side location of theCP, packlet, or link.

The side location can be front (F) sideor rear (R) side of the shelf.

p alpha Variable Indicates the position of a packlet onan input/output processor (IOP) CP.

The packlet position can be upper (U)or lower (L) position on an IOP CP.

The Packlet field remains blank ifoperating company personnel do notperform a manual test on a packlet.

252 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 253: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Field Value Fixed orVariable

Description

test_txt character string Variable Indicates the type of test. It isinservice (InSv) or out of service(OOS).

result_txt character string Variable Indicates if a selected CP, packlet, orlink passed, failed or rejected a test.

initiator_txt character string Variable Indicates the action that initiated thetest and is manual action or systemmaintenance.

reason_txt character string Variable If the test fails, the reason textindicates the reason for the failure.

FAULT RECORD ID alphanumeric Variable Indicates the identification number ofthe record that has a fault.

Active message exampleXAC640 NOV11 17:50:32 9168 INFO Test Report

TYPE Link_Num Slot Side Packlet Test_Type Result

SM 7 R InSv Passed

Initiator: Manual Action

Clear message examplen/a

Associated OM registers

XAC641This log indicates that an XA-Core alarm has been enabled or disabled bya user. Once an alarm has been disabled, it remains disabled until a userre-enables it or until a restart or SWACT occurs.

For information on enabling and disabling alarms, see the chapter"Understanding the alarm system" in the Nortel XA-Core Fault andPerformance Management (297-8991-510).

Event type: Information (INFO)

There is no XA-Core system alarm to indicate that an alarm has beendisabled.

XAC641 253

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 254: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

If an alarm has an associated OM usage register that records the length oftime during which that alarm is raised, the register records the valueregardless of whether the alarm is enabled or disabled.

The XA-Core Summary Report log (XAC400) includes a list of any alarmsthat are disabled.

Remedial actionNo immediate action.

AttributesAttribute Value

Severity Warning

FormatXACnnn mmmdd hh:mm:ss ssdd Event Type Log Title

<Alami-name>is<Alami-state>by<User-name>

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XAC641 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

Alarm-name Text string, up to sixcharacters

Variable The name of the XA-Core alarm thathas been enabled or disabled.

Alarm-state Text field, up ti eightcharacters

Variable The new state of the XA-Core alarm.Possible values are Enabled andDisabled.

User-name Text field, up to eightcharacters

Variable The name of the user who enabled ordisabled the alarm.

Active message exampleXAC641 JUN12 10:38:59 1900 INFO Alarm Enable/DisableNotification

FWvers is Disabled by ADMIN

254 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 255: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

XAC801The system generates the Memory Limit (MemLim) log (XAC801) reportwhen the available memory resources on the XA-Core drop below themajor or minor alarm thresholds.

The MemLim log report indicates the recommended action that operatingcompany personnel can follow to correct the condition.

A MemLim log report indicates one of the following alarm levels:

MemLim Major alarm: The available memory has dropped below an alarmthreshold.

MemLim Minor alarm: The system has used 90% of the available addressspace.

When the MemLim condition clears, the system generates the MemLimCondition Cleared log (XAC601) report.

Event type: Trouble (TBL)

Remedial actionContact the next level of support.

AttributesAttribute Value

Severity • Major

• Minor

FormatSeverity XACnnn mmmdd hh:mm:ss ssdd Event Type Title text

IMPACT:<System Impact Statement>

ACTION:<Action Statement>

XAC801 255

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 256: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Severity One asterisk (*) Variable Displays the severity of the associatedalarm.

Two astericks (**) indicate a majoralarm condition. Avaialble memory isbelow the major memory limitthreshold for data-store or program-store.

One asterisk (*) indicates a minoralarm condition. Available memory isbelow the minor memory limitthreshold for data-store or program-store.

Reportid XAC801 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type TBL Variable The Event Type field displays the typeof event identified in the log report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core.

ACTION Text string Variable The Action field recommends theaction that operating companypersonnel can take to correct theproblem identified in the log report.

Active message example* XAC801 MAR08 14:15:57 6700 TBL MemLim (Memory Limit)

IMPACT: A minor memory limit has been reached.

Either the amount of available data-store is 32768kb or less

or the amount of available program-store is 8192kb or less

or both.

ACTION: Contact next level of support.

Clear message examplen/a

256 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 257: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

• XASM;

XAC814A trap is a software or hardware error that causes an interruption of thesoftware process that is executing when the error occurs. If the rate of XA-Core traps exceeds the restart threshold value, a warm restart occurs.

The system generates the XATrap log (XAC814) report when the rate ofXA-Core traps (number of traps per minute) exceeds the XATRAP alarmthreshold.

The XATrap log report indicates the recommended action that operatingcompany personnel can follow to correct the condition.

An XATrap log report indicates an XATrap Major alarm condition. Thisalarm condition means the trap rate (number of traps per minute) hasexceeded the XATRAP alarm threshold.

When the XATRAP alarm condition clears, the system generates theXATrap Alarm Cleared log (XAC614).

Event type: Trouble (TBL)

Remedial actionContact the next level of support.

AttributesAttribute Value

Severity Major

FormatSeverity XACnnn mmmdd hh:mm:ss ssdd Event Type Title text

IMPACT:<System Impact Statement>

Current Trap Rate:<new trap rate>

XATrap Alarm Threshold:<trap rate threshold>

ACTION:<Action Statement>

XAC814 257

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 258: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Alarm Two asterisks (**) Variable Displays the severity of the associatedalarm.

Two asterisks (**) indicates a majoralarm condition. The trap rate (numberof traps per minute) has exceeded theXATRAP alarm threshold.

Reportid XAC814 Variable The Reportid field displays the loggroup and identification number of thelog report.

Event Type TBL Variable The Event Type field displays the typeof event identified in the log report.

IMPACT Text string Variable The Impact field describes the impactof the condition to the XA-Core.

Current Trap Rate Numeric Variable The Current Trap Rate field indicatesthe new trap rate (number of traps perminute) on the XA-Core.

XATrap AlarmThreshold

Numeric Variable The XATrap Alarm Threshold fieldindicates the trap rate (number oftraps per minute) at which theXATRAP alarm condition generates.

ACTION Text string Variable The Action field recommends theaction that operating companypersonnel can take to correct theproblem identified in the log report.

Active message example** XAC814 JAN01 14:56:13 0011 TBL XATRAP (XA-Core High TrapRate)

IMPACT: Trap rate approaching level where restart may occur.

Current Trap Rate: 6

XATrap Alarm Threshold: 6

ACTION: Contact next level of support.

Clear message examplen/a

258 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 259: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Associated OM registers

• XATrap;

XACP300Log XACP300 is generated once in every minute during which the systemdetects a high memory blocking condition.

Memory blocking occurs because XA-Core has a dynamic memory-ownership mechanism. A process will be blocked from proceeding if it triesto access memory that is currently owned by another process.

Memory blocking is a normal part of system behavior. Unusually highlevels of blocking may indicate problems that require investigation.

The levels that constitute normal memory blocking and high memoryblocking for a given software system can be determined only by conductingtesting on the software. This analysis is performed by Nortel system-engineering personnel, before the software becomes available tocustomers.

During the first ten minutes of a restart, the system collects memory-blocking data but it will not generate the XACP300 log. The reason is thathigh levels of memory blocking are expected to occur during this time.

Remedial actionContact the next level of support.

AttributesAttribute Value

Severity Indeterminate

FormatSeverity XACPnnn mmmdd hh:mm:ss ssdd Event Type Log Title

hh:mm Memory Blocking: High

Please contact your next level of support.

XACP300 259

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 260: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Severity Two asterisks (**) Variable Displays the log severity.

Reportid XACP300 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type TBL Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

Active message example** XACP300 JAN02 12:20:17 0100 TBL Memory Blocking High

12:20 Memory Blocking: High

Please contact your next level of support.

Clear message examplen/a

Associated OM registers

XACP310Log XACP310 is generated if, during a log-generation interval, the XA-Core has detected an overload condition for more than 50% of the time.

The log-generation interval is set to two minutes. If the two-minute intervallength is not suitable for you, it is possible to increase the length, up to 15minutes. If you need such an increase, please contact Nortel support.

The XA-Core performs overload analysis every second. It monitors forCallp (call processing) overload and for IO (input/output) overload. When itdetects an overload condition, it throttles new incoming originating callsuntil the overload condition has been rectified.

Under normal conditions, an overload condition does not require anymanual intervention. However, if a sustained overload condition exists overa long period, the overload may degrade the office performance andrequire further investigation.

260 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 261: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Remedial actionContact the next level of support if the overload condition is sustained overa long period.

AttributesAttribute Value

Severity Indeterminate

FormatSeverity XACPnnn mmmdd hh:mm:ss ssdd Event Type Log Title

Reason:<Reason statements>

Action: Please contact your next level of support.

Possible values for the "reason" field are asfollows:Possible values for the "reason" field are asfollows:

IO related

Callp related

Callp and IO related

Selected field descriptionsField Value Fixed or

VariableDescription

Severity Two asterisks (**) Variable Displays the log severity.

Reportid XACP310 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type TBL Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

REASON Text string Variable Provides details about the overload.

Active message example** XACP310 DEC02 10:30:45 0700 TBL Sustained Overload

Reason: IO related

Please contact your next level of support.

XACP310 261

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 262: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Clear message examplen/a

Associated OM registers

XACP500The system generates log XACP500 when memory blocking declines fromthe high level to the normal level. This log indicates that the high memoryblocking condition has cleared.

Memory blocking occurs because XA-Core has a dynamic memory-ownership mechanism. A process will be blocked from proceeding if it triesto access memory that is currently owned by another process.

The levels that constitute normal memory blocking and high memoryblocking for a given software system can be determined only by conductingtesting on the software. This analysis is performed by Nortel system-engineering personnel, before the software becomes available tocustomers.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatXACPnnn mmmdd hh:mm:ss ssdd Event Type Log Title

hh:mm Memory Blocking: Normal

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XACP500 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

262 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 263: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Active message exampleXACP500 JAN02 02:25:17 0400 INFO Memory Blocking Normal

2:25 Memory Blocking: Normal

Clear message examplen/a

Associated OM registers

XACP600Log XACP600 is generated automatically once every 15 minutes, to reportthe levels of memory blocking on the switch during the preceding 15minutes.

Memory blocking occurs because XA-Core has a dynamic memory-ownership mechanism. A process will be blocked from proceeding if it triesto access memory that is currently owned by another process.

Memory blocking is a normal part of system behavior. Unusually highlevels of blocking may indicate problems that require investigation.

The levels that constitute normal memory blocking and high memoryblocking for a given software system can be determined only by conductingtesting on the software. This analysis is performed by Nortel system-engineering personnel, before the software becomes available tocustomers.

Remedial actionn/a

AttributesAttribute Value

Severity Warning

FormatFor log XACP600, there is a long format and a short format.The system uses the long format if the blocking level hasnot been normal during each of the preceding 15 minutes. Thelong format is as follows:For log XACP600, there is a longformat and a short format. The system uses the long formatif the blocking level has not been normal during each of thepreceding 15 minutes. The long format is as follows:

XACPnnn mmmdd hh:mm:ss ssdd Event Type Log Title

XACP600 263

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 264: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

hh: mm Memory Blocking<level>

If the blocking level has been normal during each of thepreceding 15 minutes, the system uses the short format. Theshort format is as follows:If the blocking level has beennormal during each of the preceding 15 minutes, the systemuses the short format. The short format is as follows:

XACPnnn mmmdd hh:mm:ss ssdd Event Type Log Title

Memory Blocking has been Normal during the last 15 minutes.

264 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 265: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Selected field descriptionsField Value Fixed or

VariableDescription

Reportid XACP600 Variable The Reportid field displays the loggroup (XAC) and identification numberof the log report.

Event Type INFO Variable The Event Type field displays the typeof event identified in the log report.

Log title Text string Variable A text string describing the title of thelog report.

Active message exampleXACP600 JAN02 12:30:17 0900 INFO Memory Blocking Summary

12:29 Memory Blocking: Normal

12:28 Memory Blocking: Normal

12:27 Memory Blocking: High

12:26 Memory Blocking: High

12:25 Memory Blocking: High

12:24 Memory Blocking: High

12:23 Memory Blocking: High

12:22 Memory Blocking: High

12:21 Memory Blocking: High

12:20 Memory Blocking: High

12:19 Memory Blocking: Normal

12:18 Memory Blocking: Normal

12:17 Memory Blocking: Normal

12:16 Memory Blocking: Normal

12:15 Memory Blocking: Normal

XACP600 FEB07 18:30:12 6000 INFO Memory Blocking Summary

XACP600 265

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 266: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

Memory Blocking has been Normal during the last 15 minutes.

Clear message examplen/a

Associated OM registers

266 XAC alarms and logs reference

C20 Converged SoftswitchLogs and Alarms Reference, Volume 9

NN10275-909v9 12.01 03 October 2011

Copyright © 2011 GENBAND. All Rights Reserved.

Page 267: NN10275 909v9 12.01 CVM16 c20 Fault Management Logs Alarms Ref

C20 Converged Softswitch

Logs and Alarms Reference, Volume 9Release: CVM16 and upPublication: NN10275-909v9Document Revision: 12.01Document release date: 03 October 2011

Copyright © 2011 GENBAND. All rights reserved. Use of this documentation and its contents is subject to the terms and conditionsof the applicable end user or software license agreement, right to use notice, and all relevant copyright protections.

GENBAND, the GENBAND corporate logo and tagline, and certain of GENBAND's product and solution names are registeredtrademarks of GENBAND and its affiliates.

While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writingGENBAND AND/OR ITS LICENSORS PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANYKIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to changewithout notice.

THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF GENBAND OR ITS LICENSORS AND MUST NOT BEDISCLOSED, OTHER THAN TO EMPLOYEES OF GENBAND OR CUSTOMERS WITH NEED-TO-KNOW, WITHOUT THEPRIOR WRITTEN CONSENT OF GENBAND OR ITS LICENSORS. THE INFORMATION MUST NOT BE DISCLOSED TOSUBCONTRACTORS OR REGULATORY AUTHORITIES. GENBAND MUST BE NOTIFIED OF ANY REQUEST OR ORDERFOR DISCLOSURE PRIOR TO SUCH DISCLOSURE.

Software and documentation owned by or under license with Nortel Networks included in this Release or in any documentprovided with this Release is Copyright © 2010 Nortel Networks or its licensors. All rights reserved. Use of this software and/ordocumentation and its contents is subject to the terms and conditions of the applicable end user or software license agreement,right to use notice, and all relevant copyright protections. The product names remain as Carrier VoIP and CS 2000 in Canada and France pending regulatory approvals for a name change.

www.genband.com