Series CV 3000Directional Control Valve

3

Contents

General Information

Technical data

Performance Curves

Dimensions

Main Relief Valve/Service Port Valves/Spools

Spool Controls

Valve Sample

Page 10

Page 12

Page 4

Page 5

Page 6

Page 7

Page 9

Page 4: NIMCO CV3000s

Series CV 3000Directional Control Valve

4

General Information

The CV 3000 directional control valve is a sectional valve, that can be used in both open and closed center systems.

It can be adapted for open center, closed center, along with load sensing systems and operated with manual, pneumatic, hydraulic or electro hydraulic controls.

It is designed to handle up to 110 LPM/30 USGPM when operated as a traditional open center valve. It will handle 120LPM/32 Gpm in the inlet section and working flows of 110 LPM/30 USGpm at each section when operating with a pressure compensated inlet section. The maximum working pressure is 350 bar/5075 Psi with a maximum back pressure of 20 bar/290 Psi in the return lines and can be assembled up to 10 valve sections as one valve unit.

Standard Valve Version with Fixed Pump

It can be equipped with a number specially designed spools for different applications or have special spools designed for special requirements.

The inlet section can be equipped with either a main relief valve or an electrical dump to tank valve or both. Pump and tank connections can be fitted in the inlet on the left side of the valve and a pressure reducer valve can also be fitted in the inlet when the valve is being operated electro hydraulically on/off or proportionally.

The outlet section can be equipped with a H.P.C.O. (power beyond) adapter as well as equipped with a main relief valve for downstream functions.

The main relief valve and all cylinder port relief valves are direct operated and with build in anti-cavitation functions.

The CV 3000 offers a large number of spool controls, such as the enclosed manual hand lever mechanism, open spool ends, cable, pneumatic pilot, hydraulic pilot and electrical on/off or proportional controls (with manual override).

Load Sensing on Demand with Variable Pump

With a special inlet and special spools, the CV 3000 can be used as an on demand LS valve, where the pump is activated to full stroke by the activation of any one of the spools.

This inlet can be equipped with main relief valve, electrical unloading valve and a pressure-reducing valve if the valve is operated with EHP as well as the pressure compensated flow control valve communicating with the open center gallery and the pump’s LS line.

This version can be equipped with a standard outlet.

Page 5: NIMCO CV3000s

Series CV 3000Directional Control Valve

5

Technical Data

Max. pressure setting

Main relief valvePort relief valveTank line

Flow rates

Maximum pump flowMaximum flow per section

Temperature range

Standard seals

Spool leakage at

100 bar (1450 psi) and25 mm2/s (cSt)(117 SSU) viscosityA and B port

Filtration

Contamination level equal to or better then

Viscosity

Recommended operating viscosity range

Weight

Inlet sectionManual sectionOutlet sectionEHP section

Operating force necessary to move the spool

Spring centeredDetent inDetent out

Port sizes

A,B

P, T

bar

35035020

l/min.

140/120120

°C

-40 to +80

cm3/min

4-8

18/14 according to ISO 4406

mm2/s(cSt)

10-400

kg

4.94.84.76.2

N

130230200

BSP Metric SAE

1/2 M18x1,5 3/4-16 UNF SAE8or 3/4 M22x1,5 1 1/16-12 SAE12

3/4 M22x1,5 1 1/16-12 SAE12

Psi

50755075290

USGpm

37/3232

°F

-40 to +176

inch3/min

0.24-0.48

NAS 1638-class 10

SSU

47-1875

lbs

10.810.610.413.7

kp

132320

Page 6: NIMCO CV3000s

Series CV 3000Directional Control Valve

6

Pressure Drop PA(B)

Pressure Drop A(B)T

Performance Curves

25 50 75 100 125 150

10

20

30

Flow L/min

Bar

290

150

440

20 403010

psi

US gpm40

0

25 50 75 100 125 150

10

20

30

Flow L/min

Bar

290

150

440

20 403010

psi

US gpm40

0

25 50 75 100 125 150

10

20

30

Flow L/min

Bar

290

150

440

20 403010

psi

US gpm40

0

25 50 75 100 125 150

10

20

30

Flow L/min

Bar

290

150

440

20 403010

psi

US gpm40

0

Pressure Drop PT

Pressure Drop PT

Pressure Drop PA(B)

Page 7: NIMCO CV3000s

Series CV 3000Directional Control Valve

7

DimensionsManual Operator

Page 8: NIMCO CV3000s

Series CV 3000Directional Control Valve

8

DimensionsEHP + Manual Override

Page 9: NIMCO CV3000s

Series CV 3000Directional Control Valve

9

Main Relief Valve/service Port Valves/Spools

CA

A

C

RV

Description Order code

Port Relief/Anticav. valve

Anticav. valve

Port relief valve

Main relief valve

Symbol

In addition to our standard spools there are a wide range of specially designed spools to maximize load control at different pump flows and applications. Please contact our factory or any authorized distributor to discuss your specifiv requirements.

Spool type

3S

Order codestandard spool

2SB

2SA

1S

Double acting with float position

Single acting B

Single acting A

Double acting

Symbol

4S Motor

Remark

Page 10: NIMCO CV3000s

Series CV 3000Directional Control Valve

10

Spool Controls

Code A-sideType B-side CodeType

9

10

S1

S5

Spring centered.

Detent in position 1, 2 and 3

Spring centered.Detent in pos. 4.

Spring centered.Detent in pos. 3

and 4.

Spring centered.Detent in pos. 2

and 4.

12

15

11

Spring centered.Detent in pos. 2.13

Spring centered.Detent in pos. 3.14

Spring centered.Detent in pos. 1,

2, 3 and 4.16

Hand leverhorizontal.

StandardHand lever

vertical.Encased.

Hand leververtical.

Other lengthon request.

S2

Page 11: NIMCO CV3000s

Series CV 3000Directional Control Valve

11

Spool Controls

Code A-sideType B-side CodeType

EHP EHP

3W

Electricalhydraulic

proportional.12V/1.5 A

24V/0.75 A

Electricalhydraulic

proportional.12V/1.5 A

24V/0.75 AWith manual

override

Hydraulic on/off.Pilot pressureH

Hydraulicproportional.Pilot pressure

HP

Pneumaticon/off.P

Pneumaticproportional.PP 4WWire control for

4-position spool.

Wire control for3-position spool.

Hydraulic on/off.Pilot pressure H

Hydraulicproportional.Pilot pressure

HP

Page 12: NIMCO CV3000s

Series CV 3000Directional Control Valve

12

Valve Sampleopen Center Circuit - Fixed Pump

1/ Pressure relief valve2/ Solenoid valve for electrical unloading3/ Check Valve4/ Spool5/ Spool Control A-side6/ Spool Control B-side7/ Service port valve

7

6

2

1

3

5

4

Page 13: NIMCO CV3000s

Series CV 3000Directional Control Valve

13

Valve Sampleopen Center Circuit - Fixed Pump

13

4

6

8

5

7

21/ Pressure relief valve2/ Solenoid valve for electrical unloading3/ By-pass flow control spool4/ Check Valve5/ Spool6/ Spool Control A-side7/ Spool Control B-side8/ Service port valve

Page 14: NIMCO CV3000s

Series CV 3000Directional Control Valve

14

Valve SamplePressure on Demand Circuit - Variable Pump

13

4

5

7

9

8

6

2

1/ Pressure relief valve2/ Solenoid valve for electrical unloading3/ Constent flow control valve for LS-control4/ Pressure reducing/ relieving valve5/ Check Valve6/ Spool7/ Spool Control A-side8/ Spool Control B-side9/ Service port valve

Page 15: NIMCO CV3000s
Page 16: NIMCO CV3000s