Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual...

186
www.trimble.com XS Series Total Station Instruction Manual Part Number C300E1 November 2017, Revision B

Transcript of Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual...

Page 1: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

www.trimble.com

XS Series Total StationInstruction Manual

Part Number C300E1November 2017, Revision B

Page 2: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the
Page 3: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Contact InformationNikon Surveying Instruments10368 Westmoor Drive, Suite #100Westminster, CO 80021USAPhone: +1-720-587-4700888-477-7516 (Toll Free in U.S.)[email protected]

Legal Notices

Copyright and Trademarks© 2007-2017, Nikon-Trimble Co. Limited. All rights reserved.All trademarks are the property of their respective owners.It is prohibited to alter this manual in part or whole without express permission.The contents of this manual are subject to change without notice. Although every effort has been made to ensure the accuracy of this manual, please contact your dealer if you find anything in it that is incorrect or unclear.

Release NoticeThis is the November 2017 release of the XS Series Total Station Instruction Manual Edition 1, Revision B.

ManufacturerNikon-Trimble Co., Ltd.Technoport Mituiseimei Bldg.16-2, Minamikamata 2-chome, Ota-kuTokyo 144-0035 Japan

Notices

USAFCC 15B Class B satisfied.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:– Reorient or relocate the receiving antenna.– Increase the separation between the equipment and receiver.– Connect the equipment into an outlet on a circuit different from that

to which the receiver is connected.– Consult the dealer or an experienced radio/TV technician for help.

C Warning – This equipment has been certified to comply with the limits for a Class B personal computer and peripherals, pursuant to Subpart B of Part 15 of FCC Rules. Only peripherals (computer input/output devices, terminals, printers, etc.) certified to comply with the Class B limits may be attached to this equipment. Operation with non-certified personal computer and/or peripherals is likely to result in interference to radio and TV reception. The connection of a non-shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment.

You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

European UnionEU RE Directive satisfied.

Authorized Representative in EuropeTrimble GmbHAm Prime Parc 1165479 Raunheim, Germany

CanadaThis Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.Cet appareil numérique de la Class B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Taiwan

Battery RecyclingRequirementsThe product contains a removable battery. Taiwanese regulations require that waste batteries are recycled.

Notice to Our European Union CustomersFor product recycling instructions and more information, please go to: www.trimble.com/environment/summary.html

Recycling in EuropeTo recycle Trimble WEEE, call: +31 497 53 2430, and ask for the “WEEE associate,” or mail a request for recycling instructions to:Trimble Europe BVc/o Menlo Worldwide LogisticsMeerheide 455521 DZ Eersel, NL

For Bluetooth unit

USA FCC Part 15 Subpart C/RSS-210, OET bulletin 65 supplement C satisfied

C Caution – Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:– Reorient or relocate the receiving antenna.– Increase the separation between the equipment and receiver.– Connect the equipment into an outlet on a circuit different from that

to which the receiver is connected.– Consult the dealer or an experienced radio/TV technician for help.

CanadaRSS-210 Low Power DeviceOperation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

European Union countries, Iceland, Norway, Liechtenstein, Turkey, SwissEN300 328 satisfiedHereby, Nikon-Trimble Co., Ltd., declares the RE type Total station Nikon XS Series are in compliance with RED 2014/53/EU.The full text of the EU DoC is available at the following internet address: http://www.nikon-trimble.com/

RF exposure compliance 1) To comply with FCC/IC RF exposure compliance requirements, a

separation distance of at least 20 cm must be maintained between the antenna of this device and all persons.

2) This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Page 4: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

According to Taiwan NCC regulation of Administrative Regulations on Low Power Radio Waves Radiated Devices:

Article 12Without permission granted by the DGT, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices.

Article 14The low power radio-frequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved.The said legal communications means radio communications is operated in compliance with the Telecommunications Act.The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.

Page 5: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Safety 1

In this chapter:

Introduction

Warnings and Cautions

Rechargeable Lithium-ion (Li-ion) batteries

Laser Safety

Nikon XS Series Total Station Instruction Manual v

Page 6: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Safety

IntroductionFor your safety, read this instruction manual carefully and thoroughly before using the Nikon XS Series Total Station. Although Nikon products are designed for maximum safety, using them incorrectly or disregarding the instructions can cause personal injury or property damage.

You should also read the documentation for any other equipment that you use with a Nikon XS Series instrument.

Note – Always keep the manual near the instrument for easy reference.

Warnings and CautionsThe following conventions are used to indicate safety instructions:

C WARNING – Warnings alert you to situations that could cause death or serious injury.

C CAUTION – Cautions alert you to situations that could cause injury or property damage.

Always read and follow the instructions carefully.

Warnings

Before using the instrument, read the following warnings and follow the instructions that they provide:

C WARNING – Never look at the sun through the telescope. If you do, you may damage or lose your eyesight.

C WARNING – The instruments are not designed to be explosion-proof. Do not use the instrument in coal mines, in areas contaminated with coal dust, or near other flammable substances.

C WARNING – Never disassemble, modify, or repair the instrument yourself. If you do, you may receive electric shocks or burns, or the instrument may catch fire. You may also impair the accuracy of the instrument.

C WARNING – Use only the battery charger and AC adapter that are supplied with the instrument. Do not use any other charger or you may cause the battery pack to catch fire or rupture.

vi Nikon XS Series Total Station Instruction Manual

Page 7: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Safety

C WARNING – Do not cover the battery charger and AC adapter while the battery pack is being recharged. The charger must be able to dissipate heat adequately. Coverings such as blankets or clothing can cause the charger to overheat.

C WARNING – Avoid recharging the battery pack in humid or dusty places, in direct sunlight, or near heat sources. Do not recharge the battery pack when it is wet. If you do, you may receive electric shocks or burns, or the battery pack may overheat or catch fire.

C WARNING – Although the battery pack has an auto-reset circuit breaker, you should take care not to short circuit the contacts. Short circuits can cause the battery pack to catch fire or burn you.

C WARNING – Never burn or heat the battery. Doing so may cause the battery to leak or rupture. A leaking or ruptured battery can cause serious injury.

C WARNING – Before storing the battery pack or battery charger, cover the contact points with insulation tape. If you do not cover the contact points, the battery pack or charger may short circuit, causing fire, burns, or damage to the instrument.

C WARNING – The battery is not itself waterproof. Do not get the battery wet when it is removed from the instrument. If water seeps into the battery, it may cause a fire or burns.

Cautions

Before using the instrument, read the following cautions and follow the instructions that they provide:

C CAUTION – Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous radiation exposure.

C CAUTION – The tops of the tripod ferrules are very sharp. When handling or carrying the tripod, take care to avoid injuring yourself on the ferrules.

C CAUTION – Before carrying the tripod or the instrument in the carrying case, check the shoulder strap and its clasp. If the strap is damaged or the clasp is not securely fastened, the carrying case may fall, causing personal injury or instrument damage.

C CAUTION – Before setting up the tripod, make sure that no-one’s hands or feet are underneath it. When the legs of the tripod are being driven into the ground, they could pierce hands or feet.

Nikon XS Series Total Station Instruction Manual vii

Page 8: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Safety

C CAUTION – After mounting the instrument on the tripod, securely fasten the thumb screws on the tripod legs. If the thumb screws are not securely fastened, the tripod may collapse, causing personal injury or instrument damage.

C CAUTION – After mounting the instrument on the tripod, securely fasten the clamp screw on the tripod. If the clamp screw is not securely fastened, the instrument may fall off the tripod, causing personal injury or instrument damage.

C CAUTION – Securely fasten the tribrach clamp knob. If the knob is not securely fastened, the tribrach may come loose or fall off when you lift the instrument, causing personal injury or instrument damage.

C CAUTION – Do not stack objects on the plastic carrying case, or use it as a stool. The plastic carrying case is unstable and its surface is slippery. Stacking or sitting on the plastic carrying case may cause personal injury or instrument damage.

C CAUTION – The system in the instrument may stop functioning in order to avoid any errors in measurement when the instrument detects strong electromagnetic wave(s). If this is the case, turn off the instrument and remove the source of the electromagnetic wave(s). Then turn on the instrument to resume the work.

Rechargeable Lithium-ion (Li-ion) batteries

C WARNING – Do not damage the rechargeable Lithium-ion battery. A damaged battery can cause an explosion or fire, and can result in personal injury and/or property damage.To prevent injury or damage:– Do not use or charge the battery if it appears to be damaged. Signs of damage include, but

are not limited to, discoloration, warping, and leaking battery fluid.– Do not expose the battery to fire, high temperature, or direct sunlight.– Do not immerse the battery in water.– Do not use or store the battery inside a vehicle during hot weather.– Do not drop or puncture the battery.– Do not open the battery or short-circuit its contacts.

C WARNING – Avoid contact with the rechargeable Lithium-ion battery if it appears to be leaking. Battery fluid is corrosive, and contact with it can result in personal injury and/or property damage.To prevent injury or damage:– If the battery leaks, avoid contact with the battery fluid.– If battery fluid gets into your eyes, immediately rinse your eyes with clean water and seek

medical attention. Do not rub your eyes!– If battery fluid gets onto your skin or clothing, immediately use clean water to wash off the

battery fluid.

viii Nikon XS Series Total Station Instruction Manual

Page 9: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Safety

C WARNING – Charge and use the rechargeable Lithium-ion battery only in strict accordance with the instructions. Charging or using the battery in unauthorized equipment can cause an explosion or fire, and can result in personal injury and/or equipment damage.To prevent injury or damage:– Do not charge or use the battery if it appears to be damaged or leaking.– Charge the Lithium-ion battery only in a product that is specified to charge it. Be sure to

follow all instructions that are provided with the battery charger.– Discontinue charging a battery that gives off extreme heat or a burning odor.– Use the battery only in equipment that is specified to use it.– Use the battery only for its intended use and according to the instructions in the product

documentation.

Laser SafetyThe Nikon XS Series is a Class 2 laser instrument.

Nikon XS Series is a Class 2 Laser Product in accordance with: IEC60825-1:2014: “Safety of Laser Products”

Precautions: To counteract hazards, it is essential for all users to pay careful attention to the safety precautions and control measures specified in the standard IEC60825-1:2014 within the hazard distance *); particularly on to “User’s Guide”.

Note – This product complies with IEC 60825-1:2014 and IEC 60825-1:2007 and 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice no. 50. dated June 24, 2007.

C WARNING – Only qualified and trained persons should be assigned to install, adjust and operate the laser equipment.

C WARNING – Precautions should be taken to ensure that persons do not look directly, with or without an optical instrument, into the beam.

C WARNING – Laser beam path should be located well above or below eye level wherever practicable.

Nikon XS Series Total Station Instruction Manual ix

Page 10: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Safety

Bluetooth

Table 1.1 Specifications for laser emission

Laser pointer

Wave length 630-680 nm

Output power CW Po ≤ 1 mW

Disatance meter

Wave length 850-890 nm

Output power Pulse Po ≤ 22 W

Pulse width < 5 ns

Laser plummet

Wave length 635 nm

Output power CW Po < 1.0 mW

Table 1.2 Conforming standards

E.U. IEC60825-1:2014Laser Pointer: Class 2Distance Meter: Class 1Laser plummet: Class 2

USA FDA21CFR Part 1040 Sec.1040.10 and 1040.11

(except for deviations pursuant to Laser Notice No.50, dated June

24, 2007)

Laser pointer Laser plummet(This label is attached when the instrument

is laser plummet model)

Class 2 Bluetooth 2.0 EDR+ Frequency band: 2402 MHz to 2480 MHz

Maximum output power: 2.5 mW

x Nikon XS Series Total Station Instruction Manual

Page 11: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Contents1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viWarnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viCautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vii

Rechargeable Lithium-ion (Li-ion) batteries . . . . . . . . . . . . . . . . . . . . . . . . . .viiiLaser Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix

Bluetooth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x

1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Standard Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Parts of the Instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Unpacking and Packing the Instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Packing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Charging the Battery Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Detaching and Re-Attaching the Battery Pack. . . . . . . . . . . . . . . . . . . . . . . . . . 14Setting Up the Tripod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Centering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Centering using the optical plummet . . . . . . . . . . . . . . . . . . . . . . . 15Centering using the laser plummet . . . . . . . . . . . . . . . . . . . . . . . . 16Centering using a plumb bob . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Sighting and Focusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Sighting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Auto Focusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Setting the Measurement Mode and Preparing the Target . . . . . . . . . . . . . . . . . . . . 19Measurement in Reflectorless Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Measurement with a Prism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Setting Up the Prism Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Adjusting the height of the tribrach adapter . . . . . . . . . . . . . . . . . . . . . 23Changing the direction of the prism . . . . . . . . . . . . . . . . . . . . . . . 23Setting the prism constant . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Setting the position of the target plate . . . . . . . . . . . . . . . . . . . . . . . 24

Face-1/Face-2 Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24External Device Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

3 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Turning the Instrument On and Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Turning on the instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Turning off the instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Changing Regional Configuration Presets . . . . . . . . . . . . . . . . . . . . . . . . . . . 29PIN/PUK Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Display and Key Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Nikon XS Series Total Station Instruction Manual xi

Page 12: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Contents

Status bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32LCD backlight, Laser pointer, Beep sound and Contrast adjustment . . . . . . . . . . . 35[DSP] key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36[MODE] key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37[COD] key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38[HOT] key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Bubble indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Laser plummet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40[USR] keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41[DAT] key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

List Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Inputting Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Entering a point name or number . . . . . . . . . . . . . . . . . . . . . . . . . 43Entering a code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Entering values in feet and inches . . . . . . . . . . . . . . . . . . . . . . . . 47

Jobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Creating a new job . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Measuring Distances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Sighting a prism reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Measuring distances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Measurement settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

4 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53HA Reset and Angle Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Setting the horizontal angle to 0 . . . . . . . . . . . . . . . . . . . . . . . . . 54Entering the horizontal angle . . . . . . . . . . . . . . . . . . . . . . . . . . 54Recording a foresight point after repeat angle measurement . . . . . . . . . . . . . . 54Face-1/Face-2 measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Horizontal angle hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Station Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Setting up a station with known coordinates or azimuth . . . . . . . . . . . . . . . . 56Setting up a station using multiple point resection . . . . . . . . . . . . . . . . . . 59Setting up the station quickly without coordinates . . . . . . . . . . . . . . . . . . 61Determining station elevation . . . . . . . . . . . . . . . . . . . . . . . . . . 62Checking and resetting the backsight direction . . . . . . . . . . . . . . . . . . . 62Two-point resection along a known line . . . . . . . . . . . . . . . . . . . . . . 64Use last station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Stakeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Specifying the stakeout point by angle and distance . . . . . . . . . . . . . . . . . 66Specifying the stakeout point by coordinates . . . . . . . . . . . . . . . . . . . . 68DivLine S-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69RefLine S-O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

Program Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Measuring distance and offset values along a specified line . . . . . . . . . . . . . . 71Measuring distance and offset values on the arc-curve . . . . . . . . . . . . . . . . 73Remote distance measurement. . . . . . . . . . . . . . . . . . . . . . . . . . 75Measuring remote elevation . . . . . . . . . . . . . . . . . . . . . . . . . . . 77Measuring distance and offset values on the vertical plane . . . . . . . . . . . . . . . 78

xii Nikon XS Series Total Station Instruction Manual

Page 13: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Contents

Measuring distance and offset values on the slope . . . . . . . . . . . . . . . . . . 80Recording Measurement Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

Recording data from any observation screen . . . . . . . . . . . . . . . . . . . . 81Outputting data to the COM port . . . . . . . . . . . . . . . . . . . . . . . . . 82

Measuring Offsets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Measuring taped offsets . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Measuring angle offsets . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84Two-prism pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84Extending a line by horizontal angle offset . . . . . . . . . . . . . . . . . . . . . 85Entering a horizontal distance after an angle-only shot . . . . . . . . . . . . . . . . 86Calculating a corner point . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Measuring circle offsets . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Extending the slope distance. . . . . . . . . . . . . . . . . . . . . . . . . . . 89

5 Menu Key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Job Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92

Opening an existing job . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Creating a new job . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92Deleting a job . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Setting the control job . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Displaying job Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Importing a job. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Exporting a job. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

Cogo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Calculating angle and distance between two coordinates . . . . . . . . . . . . . . . 96Calculating and manually inputting coordinates . . . . . . . . . . . . . . . . . . . 98Calculating area and perimeter . . . . . . . . . . . . . . . . . . . . . . . . . 99Calculating coordinates from line and offset . . . . . . . . . . . . . . . . . . . 101Calculating coordinates using intersection functions . . . . . . . . . . . . . . . . 102

Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107Coordinate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Power saving. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109Stakeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110Recording. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110Security settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111Others settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Viewing records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Deleting records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115Editing records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Searching records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118Entering coordinates . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119Point name list and code list . . . . . . . . . . . . . . . . . . . . . . . . . . 120

Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

Nikon XS Series Total Station Instruction Manual xiii

Page 14: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Contents

Downloading data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Uploading coordinate data . . . . . . . . . . . . . . . . . . . . . . . . . . 123Uploading a point name list or code list . . . . . . . . . . . . . . . . . . . . . 125

1sec-Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126[MSR] key settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126[DSP] key settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126[USR] key settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127[S-O] key settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127[DAT] key settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127

Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Removable Memory (USB Memory). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

Displaying the external memory files . . . . . . . . . . . . . . . . . . . . . . 129Renaming a job or file on the removable memory . . . . . . . . . . . . . . . . . 130Deleting a job of file from the removable memory . . . . . . . . . . . . . . . . . 130Copying a job from the removable device . . . . . . . . . . . . . . . . . . . . 130Changing the list view of files on the removable memory . . . . . . . . . . . . . . 131

6 Checking and Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133Adjusting the Electronic Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134Checking and Adjusting the Circular Level . . . . . . . . . . . . . . . . . . . . . . . . . . 134Checking and Adjusting the Optical/Laser Plummet . . . . . . . . . . . . . . . . . . . . . . 134Zero Point Errors of Vertical Scale and Horizontal Angle Corrections . . . . . . . . . . . . . . 135

Checking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135Adjusting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135

Auto Focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137Adjusting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137

Checking the Instrument Constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138Checking the Laser Pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139

7 System Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142

8 Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145Uploading Coordinate Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146Record format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

Uploading Point Lists and Code Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148File format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148Data example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149

Downloading Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Nikon raw record formats . . . . . . . . . . . . . . . . . . . . . . . . . . 150SDR2x and SDR33 record formats . . . . . . . . . . . . . . . . . . . . . . . 153Data examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157

9 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161Cogo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162

xiv Nikon XS Series Total Station Instruction Manual

Page 15: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Contents

Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163Job Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164Recording Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165Searching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166Stakeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166Station Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167System Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168

Nikon XS Series Total Station Instruction Manual xv

Page 16: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Contents

xvi Nikon XS Series Total Station Instruction Manual

Page 17: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

1

Introduction 1

In this chapter:

Welcome

Standard Components

Parts of the Instrument

Maintenance

Nikon XS Series Total Station Instruction Manual 1

Page 18: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

1 Introduction

WelcomeThank you for purchasing this Nikon product.

This instruction manual was written for the users of Nikon XS Series Total Station instruments. Before you operate a Nikon XS Series Total Station, read this manual carefully. In particular, pay attention to the warnings and cautions that appear in the Safety section at the front of the manual. Before you begin, you should also read the maintenance instructions. For more information, see Maintenance, page 6.

2 Nikon XS Series Total Station Instruction Manual

Page 19: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Introduction 1

Standard Components• Instrument main body

• Battery pack (x 2)

• Universal charger, power cord, and adapters

• Adjustment pin, Allen wrench

• Objective lens cap

• Rain/dust cover

• Carrying case

• Shoulder strap (x 2)

Nikon XS Series Total Station Instruction Manual 3

Page 20: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

1 Introduction

Parts of the InstrumentFigure 1.1 and Figure 1.2 show the main parts of the Nikon XS Series Total Station.

Figure 1.1 Nikon XS Series Total Station – Face-1

Telescope

Telescope

Diopter ring

Face-1 display /

Horizontal axis

Vertical tangent

Battery box

Horizontal

screw

tangent screw

focusing ring

eyepiece

keyboard

Carrying handle

Optical sight(Finder)

Reticle plate cover

Tribrach clamp knob

Battery box release knob

indication mark

Horizontal clamp

Vertical clamp

The Laser Safety label shown below is attached to the telescope.

The Laser Safety label shown below will be attached here (underside) when the instrument is laser plummet model.

Figure shows the optical plummet model. The Nikon XS Series is available in both an optical plummet model and a laser plummet model.

4 Nikon XS Series Total Station Instruction Manual

Page 21: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Introduction 1

Figure 1.2 Nikon XS Series Total Station – Face-2

Figure shows the optical plummet model. The Nikon XS Series is available in both an optical plummet model and a laser plummet model.

Horizontal axisindication mark

Objective

Battery box

LASER LIGHT ISEMITTED FROM

THIS PART.

Data output /external powerinput connector

Input voltageshall be

Battery box

The Laser Safety label shown below is attached to

.the telescope.

release knob

Leveling screw

Tribrach

Optical or optional laser

plummet (This picture shows the optical plummet.)

4.5-5.2 V DCCircular level

The label shown below is attached to the underside of the keyboard.

The label shown below is attached to the underside of the keyboard.

USB port

Nikon XS Series Total Station Instruction Manual 5

Page 22: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

1 Introduction

MaintenanceBefore using the instrument, read and follow the following maintenance instructions:

• Do not leave the instrument in direct sunlight or in a closed vehicle for prolonged periods. Overheating the instrument may reduce its efficiency.

• If the instrument has been used in wet conditions, immediately wipe off any moisture and dry the instrument completely before returning the instrument to the carrying case. The instrument contains sensitive electronic assemblies which have been well protected against dust and moisture. However, if dust or moisture gets into the instrument, severe damage could result.

• Sudden changes in temperature may cloud the lenses and drastically reduce the measurable distance, or cause an electrical system failure. If there has been a sudden change in temperature, leave the instrument in a closed carrying case in a warm location until the temperature of the instrument returns to room temperature.

• Do not store the instrument in hot or humid locations. In particular, you must store the battery pack in a dry location at a temperature of less than 30 °C (86 °F). High temperature or excessive humidity can cause mold to grow on the lenses. It can also cause the electronic assemblies to deteriorate, and so lead to instrument failure.

• Store the battery pack with the battery discharged.

• When storing the instrument in areas subject to extremely low temperatures, leave the carrying case open.

• When adjusting the leveling screws, stay as close as possible to the center of each screw’s range. The center is indicated by a line on the screw.

• If the tribrach will not be used for an extended period, lock down the tribrach clamp knob and tighten its safety screw.

• Do not overtighten any of the clamp screws.

• When adjusting the vertical tangent screw and horizontal tangent screw, stay as close as possible to the center of each screw’s range. The center is indicated by a line on the screw. For final adjustment of the tangent screws, rotate the screw clockwise.

• Do not use organic solvents (such as ether or paint thinner) to clean the non-metallic parts of the instrument (such as the keyboard) or the painted or printed surfaces. Doing so could result in discoloration of the surface, or in peeling of printed characters. Clean these parts only with a soft cloth or a tissue, lightly moistened with water or a mild detergent.

• To clean the optical lenses, lightly wipe them with a soft cloth or a lens tissue that is moistened with alcohol.

6 Nikon XS Series Total Station Instruction Manual

Page 23: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Introduction 1

• The reticle plate cover has been correctly mounted. Do not release it or subject it to excessive force to make it watertight.

• Before attaching the battery pack, check that the contact surfaces on the battery and instrument are clean.

• Securely press the cap that covers the data output/external power input connector terminal. The instrument is not watertight if the cap is not attached securely, or when the data output/external power input connector is used.

• The carrying case is designed to be watertight, but you should not leave it exposed to rain for an extended period. If exposure to rain is unavoidable, make sure that the carrying case is placed with the Nikon nameplate facing upward.

• The battery pack contains a Lithium-ion battery. When disposing of the battery pack, follow the laws or rules of your municipal waste system.

• The instrument can be damaged by static electricity from the human body discharged through the data output/external power input connector. Before handling the instrument, touch any other conductive material once to remove static electricity.

• Be careful not to pinch your finger between the telescope and trunnion of the instrument.

Reticle plate cover

Nikon XS Series Total Station Instruction Manual 7

Page 24: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

1 Introduction

8 Nikon XS Series Total Station Instruction Manual

Page 25: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

2

Preparation 2

In this chapter:

Unpacking and Packing the Instrument

Charging the Battery Pack

Detaching and Re-Attaching the Battery Pack

Setting Up the Tripod

Centering

Leveling

Sighting and Focusing

Setting the Measurement Mode and Preparing the Target

Measurement in Reflectorless Mode

Measurement with a Prism

Setting Up the Prism Reflector

Face-1/Face-2 Measurement

External Device Connector

Nikon XS Series Total Station Instruction Manual 9

Page 26: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

Unpacking and Packing the InstrumentNote – Handle the instrument gently to protect it from shocks and excessive vibration.

Unpacking

To unpack the instrument, grip the carrying handle and gently remove the instrument from the carrying case.

Packing

To pack the instrument back into the carrying case, please refer to the figure on the right.

Charging the Battery PackBefore charging the battery pack, read the warnings (also listed in the Safety section at the front of this manual) and the following notes.

C WARNING – Do not damage the rechargeable Lithium-ion battery. A damaged battery can cause an explosion or fire, and can result in personal injury and/or property damage.To prevent injury or damage:– Do not use or charge the battery if it appears to be damaged. Signs of damage include, but

are not limited to, discoloration, warping, and leaking battery fluid.– Do not expose the battery to fire, high temperature, or direct sunlight.– Do not immerse the battery in water.– Do not use or store the battery inside a vehicle during hot weather.– Do not drop or puncture the battery.– Do not open the battery or short-circuit its contacts.

C WARNING – Avoid contact with the rechargeable Lithium-ion battery if it appears to be leaking. Battery fluid is corrosive, and contact with it can result in personal injury and/or property damage.To prevent injury or damage:– If the battery leaks, avoid contact with the battery fluid.– If battery fluid gets into your eyes, immediately rinse your eyes with clean water and seek

medical attention. Do not rub your eyes!– If battery fluid gets onto your skin or clothing, immediately use clean water to wash off the

battery fluid.

10 Nikon XS Series Total Station Instruction Manual

Page 27: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Preparation 2

C WARNING – Charge and use the rechargeable Lithium-ion battery only in strict accordance with the instructions. Charging or using the battery in unauthorized equipment can cause an explosion or fire, and can result in personal injury and/or equipment damage.To prevent injury or damage:– Do not charge or use the battery if it appears to be damaged or leaking.– Charge the Lithium-ion battery only in a product that is specified to charge it. Be sure to

follow all instructions that are provided with the battery charger.– Discontinue charging a battery that gives off extreme heat or a burning odor.– Use the battery only in equipment that is specified to use it.– Use the battery only for its intended use and according to the instructions in the product

documentation.

C WARNING – To charge the battery pack, use only the battery charger and AC adapter that are supplied with the instrument. Do not use any other charger or you may cause the battery pack to catch fire or rupture. The enclosed battery pack cannot be used with other chargers.

C WARNING – Do not cover the battery charger and AC adapter while the battery pack is being recharged. The charger must be able to dissipate heat adequately. Coverings such as blankets or clothing can cause the charger to overheat.

C WARNING – Avoid recharging the battery pack in humid or dusty places, in direct sunlight, or near heat sources. Do not recharge the battery pack when it is wet. If you do, you may receive electric shocks or burns, or the battery pack may overheat or catch fire.

C WARNING – Although the battery pack has an auto-reset circuit breaker, you should take care not to short circuit the contacts. Short circuits can cause the battery pack to catch fire or burn you.

C WARNING – Never burn or heat the battery. Doing so may cause the battery to leak or rupture. A leaking or ruptured battery can cause serious injury.

C WARNING – Before storing the battery pack or battery charger, cover the contact points with insulation tape. If you do not cover the contact points, the battery pack or charger may short circuit, causing fire, burns, or damage to the instrument.

C WARNING – The battery is not itself waterproof. Do not get the battery wet when it is removed from the instrument. If water seeps into the battery, it may cause a fire or burns.

Nikon XS Series Total Station Instruction Manual 11

Page 28: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

Applying Power

• Plug in the charger to the supplied AC adapter to turn the unit on. The power input must be 5 V with at least 4 A of current capability. Each battery may take up to 2 A while charging.

Charging a battery

• Simply slide a battery into either battery slot to begin charging. The adjacent charge indicator will illuminate yellow when charging is in progress. The charge indicator will change to green when charging is complete.

• Two battery slots are independent of each other. A battery slot can be used regardless of the state of the other battery slot.

• Charging a normally discharged battery may take 3 to 6 hours.

• Charging an exhausted battery which has not been used for several months may take up to 7 hours.

• Li-Ion battery is designed not to be charged when its temperature becomes higher than 40 °C to 45 °C. In such conditions, the charge indicator will blink to warn the battery is too hot to continue charging. Wait for a while and the charging will resume after the battery has cooled down. As a result, note that the charging time will be longer.

Charge indicator 1

Calibrationindicator 1

Calibration button

Calibrationindicator 2

Charge indicator 2

Power jack

This will read 5V, 4A

Case“Top” edge

Battery Slot 1

Battery Slot 2

12 Nikon XS Series Total Station Instruction Manual

Page 29: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Preparation 2

• If the charge indicator(s) are blinking and the batteries feel cool, it may indicate a problem with the battery or the charger. If the charge light is still blinking after trying several batteries which are not warm, there is a problem with the unit or the batteries themselves.

Conditioning / calibrating a battery

• Battery calibration is necessary about once every 6 months or more often if desired. Calibration ensures the reported battery charge remaining is accurate.

• Hold down the calibration button on the unit and then insert a battery while holding the calibration button to begin a battery calibration. Only the battery which was inserted while the button was depressed will begin calibration. During a battery calibration the battery will be charged, discharged completely, and then recharged before finishing. Calibration should complete in roughly 22 hours and the charger vents should not be covered during a calibration cycle.

• The blue calibration indicator light(s) will blink slowly (on 1.5 sec, off 2 sec) while a calibration is in progress and the charge light(s) may be on or off during the calibration cycle.

• When a calibration cycle is completed, the calibration light will stop blinking and remain on until the corresponding battery is removed.

• The bottom case temperature may continue to climb up to approximately 43 °C before temperature regulation is enabled to keep the case from getting warmer. As the battery voltage drops, the case will cool down and the automatic temperature limiting will no longer be necessary which minimizes the time it takes to discharge a battery.

• If the case temperature continues to get too hot internally even after temperature regulation is enabled, there is a secondary failsafe which will abort the calibration completely. If an abort occurs, the calibration light(s) will blink rapidly and battery charging will be re-enabled.

Nikon XS Series Total Station Instruction Manual 13

Page 30: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

Detaching and Re-Attaching the Battery Pack

Detaching the battery pack

C CAUTION – Avoid touching the contacts on the battery pack.

1. If the instrument is turned on, press [PWR] to turn it off.

2. Turn the battery box release knob counterclockwise, open the battery box cover and remove the battery pack from the battery box.

Inserting the battery pack

Before inserting the battery pack, clear any dust or other foreign particles from the battery contacts.

1. Turn the battery box release knob counterclockwise and open the battery box cover.

2. Put the battery pack into the battery box. Insert the battery pack with the connectors bottom first, facing inside.

3. Close the battery box cover and turn the knob clockwise until the secure click sound is heard.

C CAUTION – If the battery box cover is not closed, this could adversely affect the watertightness of the instrument.

1

2 3

14 Nikon XS Series Total Station Instruction Manual

Page 31: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Preparation 2

Setting Up the Tripod

C CAUTION – The tops of the tripod ferrules are very sharp. When handling or carrying the tripod, take care to avoid injuring yourself on the ferrules.

1. Open the tripod legs enough to for the instrument to be stable.

2. Locate the tripod directly over the station point. To check the tripod’s position, look through the center hole in the tripod head.

3. Firmly press the tripod ferrules into the ground.

4. Level the top surface of the tripod head.

5. Securely fasten the thumb screws on the tripod legs.

6. Place the instrument on the tripod head.

7. Insert the tripod mounting screw into the center hole of the base plate of the instrument.

8. Tighten the tripod mounting screw.

Note – Do not carry the instrument while it is attached to a tripod.

CenteringWhen you center the instrument, you align its central axis precisely over the station point. To center the instrument, you can either use the laser or optical plummet or a plumb bob.

Centering using the optical plummet

Note – If you require high accuracy, check and adjust the optical plummet before you center the instrument. For detailed instructions, see Checking and Adjusting the Optical/Laser Plummet, page 134.

To center the instrument using the optical plummet:

1. Set up the instrument on the tripod. For detailed instructions, see Setting Up the Tripod, page 15.

2. While looking through the optical plummet, align the reticle with the station point. To do this, turn the leveling screws until the center mark of the reticle is directly over the image of the station point.

3. While supporting the tripod head with one hand, loosen the tripod leg clamps and adjust the lengths of the legs until the air bubble is in the center of the circular level.

4. Tighten the tripod leg clamps.

Nikon XS Series Total Station Instruction Manual 15

Page 32: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

5. Use the electronic level to level the instrument. For detailed instructions, see Leveling, page 17.

6. Look through the optical plummet to check that the image of the station point is still in the center of the reticle mark.

7. If the station point is off center, do one of the following:

– If the station point is slightly off center, loosen the tripod mounting screw and then center the instrument on the tripod. Use only direct movement to center the instrument. Do not rotate it.

When the instrument is centered, tighten the mounting screw.

– If the displacement of the station point is major, repeat this procedure from Step 2.

Centering using the laser plummet

Note – Do NOT look into the laser directly.

Note – If you require high accuracy, check and adjust the laser plummet before you center the instrument. For detailed instructions, see Checking and Adjusting the Optical/Laser Plummet, page 134.

1. Set up the instrument on the tripod. For detailed instructions, see Setting Up the Tripod, page 15.

2. Turn on the laser plummet. See Laser plummet ON/OFF, page 40.

3. Align the laser pointer to the station point. To do this, turn the leveling screws until the laser pointer is over the station point.

4. While supporting the tripod head with one hand, loosen the tripod leg clamps and adjust the lengths or the legs until the air bubble is the center of the circular level.

5. Tighten the tripod leg clamps.

6. Use the electronic level to level the instrument. For detailed instructions, see Leveling, page 17.

7. Check the laser pointer is over the station point.

8. If the station point is off center, do one of the following:

– If the station point is slightly off center, loosen the tripod mounting screw and then center the instrument on the tripod. Use only direct movement to center the instrument. Do not rotate it.

– When the instrument is centered, tighten the mounting screw.

– If the displacement of the station point is major, repeat this procedure from Step 2

16 Nikon XS Series Total Station Instruction Manual

Page 33: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Preparation 2

Centering using a plumb bob

1. Set up the instrument on the tripod. For detailed instructions, see Setting Up the Tripod, page 15.

2. Hang the plumb line on the hook of the tripod mounting screw.

3. Adjust the length of the plumb line so that the tip of the plumb bob is at the height of the station point.

4. Loosen the tripod mounting screw slightly.

5. Using both hands to support the outer side of the tribrach, carefully slide the instrument about on the tripod head until the tip of the plumb bob is positioned over the exact center of the station point.

Note – To confirm that the instrument is precisely aligned, check its position from two directions at right angles to each other.

LevelingWhen you level the instrument, you make the vertical axis of the instrument exactly vertical. To level the instrument, use the electronic level. In the leveling work, always set the instrument in face 1 direction (please refer to the Fig.1.1 in page 3).

To level the instrument:

1. Move the bubble into the circle drawn on the circular level and then turn on the power.

2. Rotate the alidade until the bottom edge of the keyboard panel is parallel to the two of the leveling screws (B and C).

3. Use leveling screws B and C to move the bubble into the center of the electronic level.

4. Use leveling screw A to move the bubble into the center of the electronic level.

5. Repeat Step 2 through Step 4 to center the bubble.

6. Rotate the alidade 180°.

7. If the bubble in the electronic level remains centered, the instrument is level. If the bubble moves off center, adjust the electronic level. For detailed instructions, see Adjusting the Electronic Level, page 134.

B C

A

Bottom edge of the keyboard panel

Nikon XS Series Total Station Instruction Manual 17

Page 34: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

Sighting and Focusing

Sighting

When you sight the instrument, you aim the telescope at the target, bring the target image into focus, and align the image with the center crosshairs of the reticle.

To sight the instrument:

1. Adjust the diopter:

a. Aim the telescope at a blank area, such as the sky or a piece of paper.

C WARNING – Never look at the sun through the telescope. If you do, you may damage or lose your eyesight.

b. Looking through the eyepiece, rotate the diopter ring until the reticle crosshairs are in sharp focus.

2. Eliminate parallax:

a. Aim the telescope at the target image.

b. Rotate the focusing ring until the target image is in sharp focus on the reticle crosshairs.

c. Move your eye vertically and laterally to check whether the target image moves relative to the reticle crosshairs.

If the target image does not move, there is no parallax.

d. If the target image does move, rotate the telescope focusing ring. Then repeat from Step c.

3. Rotate the tangent screw:

– The final turn of the tangent screw should be in a clockwise direction, to align the target accurately on the center crosshairs.

– The focusing lens is driven by a motor when the telescope focusing ring is turned.

Note – To move the focusing lens, you need to power ON the instrument.

Centercrosshairs

Diopter ring Telescope focusingring

18 Nikon XS Series Total Station Instruction Manual

Page 35: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Preparation 2

Auto Focusing

Use autofocus to focus to a target automatically. First ensure AF is enabled, see Auto Focus, page 109 for autofocus settings, then press [AF] key.

The Auto Focusing system focuses the lens using a distance captured by the EDM. At any time the manual focus ring can be used for precise adjustments to the focus.

The Auto Focusing system uses distance taken by EDM to drive the focusing lens to the appropriate position. Therefore, an EDM distance is required, if the instrument is to Auto Focus.

To best obtain the required distance for the EDM, rough sighting by optical sight (Finder) is needed.

The focusing is based on the center of the telescope (cross-hair sighting).

After turning the focusing ring, the instrument will remain in manual focusing mode until the [AF] key is next pressed.

Setting the Measurement Mode and Preparing the TargetThe Nikon XS Series has two measurement modes: Prism mode (Prism) and Reflectorless mode (N-Prism). These modes can be changed at any time by holding down the [MSR1] or [MSR2] key for one second. For more information, see Measurement settings, page 50.

To set the measurement mode depending on the target you want to measure, see the following table.

In some cases, you can measure another target that is not appropriate to the set measurement mode.

Note – The Nikon XS Series is Laser Class 1 in the measurement function, and Laser Class 2 in the Laser pointer function.Don’t sight the Prism when the Laser Pointer is on.

Target Target setting

Prism, reflector sheet Prism (Prism mode)

Other (reflective materials) N-Prism (Reflectorless mode)

Nikon XS Series Total Station Instruction Manual 19

Page 36: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

Measurement in Reflectorless ModeThe intensity of the reflection from the target determines the distance the Nikon XS Series can measure in this mode. The color and condition of the target surface also affect the measurable distance, even if the targeted objects are the same. Some less-reflective targets may not be measured.

The following table describes some examples of targets and approximate measureable distances.

Measurable distances may be shorter or measurement intervals may be longer in the following cases:

• the angle of the laser against the target is small

• the surface of the target is wet

In direct sunlight, the measurable distance may be shorter. In this case, try to throw a shadow on the target.

Targets with completely flat surfaces, such as mirrors, cannot be measured unless the beam and the target are perpendicular to each other.

Target You can measure approximately...

Traffic signs, reflectors 800 meters (2624 feet)

Paper (white), veneer (new) 450 meters (1476 feet)

Wall (brightly painted), brick 150 to 300 meters (492 to 984 feet)

Make sure there are no obstacles between the instrument and the target when taking measurents.

When you need to take measurements across a road or a place where vehicles or other objects are frequently moving, take several measurements to a target for the best result.

20 Nikon XS Series Total Station Instruction Manual

Page 37: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Preparation 2

Measurement with a PrismDo not use a prism with scratches, a dirty surface, or a chipped center. Prisms with thin edges are recommended.

As the Nikon XS Series are extremely sensitive, multiple reflections on the prism surface can sometimes cause a significant loss in accuracy.

To maintain the accuracy of your measurements:

• When measuring a short distance, incline the prism slightly so that the EDM can ignore unnecessary reflections on the prism surface, as shown below.

Hold the prism securely in place and do not move while taking measurements.

In Prism mode, in order to avoid false measurements on objects other than the prism or reflector-sheet, targets that are less reflective than the prism or reflector sheet are not measured. Even if measurement is started, measured values are not displayed. To measure less reflective objects, use the N-prism (reflectorless) mode

thin edges chipped center thick edges

3 5 5

Nikon XS Series Total Station Instruction Manual 21

Page 38: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

Setting Up the Prism Reflector1. Assemble the prism reflector as shown below.

2. Adjust the height of the tribrach adaptor (see page 23).

3. If necessary, change the direction of the prism (see page 23).

4. Set the prism constant (see page 23).

5. If you are using a single prism holder, set the position of the target plate (see page 24).

Detailed instructions for Step 2 through Step 5 are provided on the following pages.

Note – The instrument must be used with the Tribrach W30S or W30Sb.

Tribrach

Tribrach

Tripod

Target plate for single prism

Tiltable singleprism holder

Prism C

Target pole

Triple prism holder

Height adjust- ment adapter

is not used.

W30S/W30Sb

adapter 15

22 Nikon XS Series Total Station Instruction Manual

Page 39: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Preparation 2

Adjusting the height of the tribrach adapter

The tribrach adapter has a height adjustment adapter. To use the prism reflector with the instrument, remove the height adjustment adapter as shown in the Figure below.

The height adjustment adapter will be used with other Nikon Total Stations, except for Nivo Series, XS Series and XF Series.

Changing the direction of the prism

The prism mounted on the tribrach adapter can be rotated to face in any direction.

To change the direction of the prism:

1. Release the rotation clamp. To do this, turn the clamp lever counterclockwise.

2. Turn the upper plate of the tribrach adapter until the prism is facing in the required direction.

3. Fasten the rotation clamp. To do this, turn the clamp lever clockwise.

Setting the prism constant

1. Attach the prism to the single prism holder or triple prism holder.

B Tip – To use a triple prism holder as a single prism holder, attach the prism to the center thread of the prism holder.

2. Set the prism constant. To do this, hold down [MSR1] or [MSR2] for one second. For more information, see Measurement settings, page 50.

Note – The prism constant of a Nikon prism is always 0, whether it is attached to a single prism holder or a triple prism holder.

B Tip – When you use the prism at a short distance, set the prism at a slight angle to the sighting axis, rather than completely square.

If your prism constant is not 0 mm, then directly enter the prism constant value in the Const field. For example, if your prism constant is 30 mm, enter 30mm in the Const field on the instrument.

Height adjustment adapter

Height adjustment adapter clamp screw

Clamp

Clamp lever

Unclamp

Nikon XS Series Total Station Instruction Manual 23

Page 40: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

Setting the position of the target plate

If using a single prism, make sure that the target plate is aligned with the tribrach adapter and the prism.

To set the position of the target plate:

1. Use the two set screws supplied to attach the target plate to the single prism holder.

2. Move the target plate within the screw holes until the apex of the wedge pattern is aligned with the vertical axis of the prism and the tribrach adapter.

Face-1/Face-2 MeasurementYou can take a measurement from either face of the instrument. To change the face, rotate the instrument 180° on its base, and rotate the telescope 180° within the standard.

By averaging the Face-1 and Face-2 measurement values, you can cancel out most constant mechanical errors. Some errors, such as vertical axis error, cannot be cancelled out by averaging Face-1 and Face-2 measurements.

C CAUTION – When rotating the telescope, take care not to catch your finger in the gap between the instrument’s standard and the telescope.

A Face-1 measurement is made with the vertical circle positioned to the left of the telescope eyepiece. A Face-2 measurement is made with the vertical circle positioned to the right of the telescope eyepiece.

Center on axis

Face-1 Face-2

24 Nikon XS Series Total Station Instruction Manual

Page 41: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Preparation 2

External Device ConnectorThis connector can be used to connect to an external power source or to communicate with an external device.

Before using the external device connector, make sure that the external device meets the specifications below.

C CAUTION – Except for the connection shown in Figure 7.1 on page 142, use of this connector is at your own risk.

C CAUTION – Use only the male connectors specified above. Using other connectors will damage the instrument.

The external device connector is a Hirose HR 10A-7R-6S female connector. The pinouts for connecting it to an external device connector are shown below:

C CAUTION – Use only the pin connections shown above. Using other connections will damage the instrument.

C CAUTION – The Nikon XS and XF Series Total Stations have different pin assignment from other models of Nikon total station.

To connect to an external power source, supply power to Pin 4 (power terminal) and Pin 5 (ground terminal) on the instrument. The instrument will use the external power source even if the internal battery packs are attached.

C CAUTION – Make sure that the power supplied is within the rated input range (4.5 V to 5.2 V DC, 1 A maximum). Power supplied outside this range will damage the instrument.

Input voltage 4.5 V to 5.2 V DC

System RS-232C

Signal level ±9 V standard

Maximum baud rate 38400 bps asynchronous

Compatible male connector Hirose HR10A-7P-6P or HR10-7P-6P

Pin Signal Description

1 RXD Receive data (Input)

2 TXD Send data (Output)

3 NC No connection

4 V Power

5 GND Ground

6 NC No connection

HRS

16

2534

Nikon XS Series Total Station Instruction Manual 25

Page 42: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

2 Preparation

To communicate with an external device, connect the RS-232C signal from the external device to Pin 1 (input terminal) and to Pin 2 (output terminal) on the instrument.

Cap the data output/external power input connector securely while not in use. The instrument is not watertight if the cap is not attached or not attached securely, and when the data output/external power input connector is in use.

The instrument can be damaged by static electricity from the human body discharged through the data output/external power input connector. Before handling the instrument, touch any other conductive material once to remove static electricity.

26 Nikon XS Series Total Station Instruction Manual

Page 43: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

3

Getting Started 3

In this chapter:

Turning the Instrument On and Off

Changing Regional Configuration Presets

PIN/PUK Lock

Display and Key Functions

List Display

Inputting Data

Jobs

Measuring Distances

Nikon XS Series Total Station Instruction Manual 27

Page 44: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

Turning the Instrument On and Off

Turning on the instrument

1. To turn on the instrument, press [PWR]. The start-up screen appears. It shows the model name, current temperature, pressure, date, and time.

The display automatically changes to the electronic level after 2 seconds.

Turning off the instrument

To enter the power-off process, press [PWR] and [ENT].

Then do one of the following:

Sleep mode

If you press the Sleep softkey in the Press [ENT] → OFF screen, or enable the Power Save setting (see Power saving, page 109), the instrument goes into sleep mode.

When the instrument is in sleep mode, it wakes up if any of the following occurs:

• You press a key

• The instrument receives a remote control command

• You rotate the alidade

• You tilt the telescope

If you have entered your name or your company’s name in the Owner’s detail field, the text from this field appears on the start-up screen. To set the Owner’s detail field, go to MENU > Settings > Others. For more information, see page 112.

Press … to …

[ENT] again turn off the instrument

the Reset softkey reboot the program and re-start the instrument

the Sleep softkey put the instrument into power-saving mode

[ESC] cancel the power-off process and return to the previous screen

If you press the Reset softkey, the software is rebooted and the Basic Measurement Screen (BMS) appears without an open job.

28 Nikon XS Series Total Station Instruction Manual

Page 45: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

Changing Regional Configuration PresetsTo provide easier configuration for common regional settings, you can quickly configure the Nikon total station to a pre-set combination of default regional settings. The Regional Configuration screen appears only after the language configuration is complete, the instrument has rebooted.

1. Follow the steps in Language, page 112.

Once the instrument rebooted, the Regional Configuration screen appears.

2. Press [^] or [v] to highlight the required regional settings and then press [ENT].

3. If you do not want to change the current settings, press [ESC] and quit. The instrument will continue to use the last configured settings that were configured.

The settings affected by the Regional Configuration screen are:

Category Setting Europe International United States

Angle VA zero Zenith Zenith Zenith

Resolution 1"(See note) 1"(See note) 1"(See note)

HA Azimuth Azimuth Azimuth

Distance Scale 1.000000 1.000000 1.000000

T-P corr. On On On

Sea Level Off Off Off

C&R corr. 0.132 0.132 0.132

Coordinates Order ENZ ENZ NEZ

Label ENZ ENZ NEZ

AZ zero North North North

Power Save Main Unit Off Off Off

EDM Unit Off Off Off

Auto Focus Sig+Key Sig+Key Sig+Key

Sleep 5 minutes 5 minutes 5 minutes

Communication Ext. Comm Nikon Nikon Nikon

Baud 4800 4800 4800

Length 8 8 8

Parity None None None

Stop bit 1 1 1

Stakeout Add PT 1000 1000 1000

Units Angle GON DEG DEG

Distance meters meters US-ft

Temp °C °C °F

Press mm Hg mm Hg In Hg

Rec Store DB RAW&XYZ RAW&XYZ RAW&XYZ

Nikon XS Series Total Station Instruction Manual 29

Page 46: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

The default regional configuration pre-set is “United States” settings. For more information, see Settings, page 106.

PIN/PUK LockIf a PIN/PUK security code are activated by the user, a PIN Code enter screen appears. Enter the PIN Code.

If the wrong code is entered more than 10 times, the instrument will be locked and the PUK needs to be entered. See Security settings, page 111.

Display and Key FunctionsThe following figure shows the keys on the Nikon XS Series instrument keyboard and the LCD display.

The functions of the instrument keys are as follows.

Data Rec Internal Internal Internal

Others XYZ disp Fast Fast Fast

2nd Unit None None None

Split ST No No No

CD Input <ABC> <ABC> <ABC>

Signal Beep Off Off Off

Owner’s Detail Blank Blank Blank

Key Function Details

Turns the instrument on or off. page 28

(Illumination key)

Provides access to the switch window.

Turns on/off the LCD backlight if held down for one second.

page 35

Category Setting Europe International United States

30 Nikon XS Series Total Station Instruction Manual

Page 47: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

Displays the MENU screen. page 91

Changes the key input mode between alphanumeric and numeric if pressed when you are in a PT or CD field.

Activates Qcode mode if pressed when you are In the Basic Measurement Screen (BMS).

page 37

Records measured data, moves on to the next screen, or confirms and accepts the entered data in input mode.

You have the option to record the measurement as a CP record instead of an SS record, if you hold this key down for one second in the Basic Measurement Screen (BMS).

The instrument outputs the current measurement data (PT, HA, VA, and SD) on the COM port if you press this key in the BMS or in a Stakeout observation screen. (The Data Rec settings must be set to COM.)

page 81

Returns to the previous screen.

In numeric or alphanumeric mode, deletes input.

Starts distance measurement, using the measure mode settings for the [MSR1] key.

Displays measurement mode settings, if held down for one second.

page 49

Starts distance measurement, using the measure mode settings for the [MSR2] key.

Displays measurement mode settings, if held down for one second.

page 49

Moves to the next available display screen.

Changes the fields that appear on the DSP1, DSP2, and DSP3 screens, if held down for one second.

page 51

Displays the Angle menu. page 54

Displays the Station Setup menu.

In numeric mode, enters 7. In alphanumeric mode, enters 7.

page 56

Displays the Stakeout menu.

Shows stakeout settings, if held down for one second.

In numeric mode, enters 8. In alphanumeric mode, enters A, B, C, or 8.

page 66

Displays the Offset Point Measurement menu.

In numeric mode, enters 9. In alphanumeric mode, enters D, E, F, or 9.

page 83

Displays the Programs menu, which contains additional measuring programs.

In numeric mode, enters 4. In alphanumeric mode, enters G, H, I, or 4.

page 71

Key Function Details

Nikon XS Series Total Station Instruction Manual 31

Page 48: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

Status bar

The status bar appears on the right side of every screen. It contains icons that indicate the status of various system functions.

Displays the (HOT) menu, which includes Height of Target, Temp-Press, Target, Note recording, and Default PT settings.

In numeric mode, enters 5. In alphanumeric mode, enters J, K, L, or 5.

page 38

Displays RAW, XYZ, or STN data, depending on your setting.

In numeric mode, enters 6. In alphanumeric mode, enters M, N, O, or 6.

page 42

Executes the function that is assigned to the [USR1] key.

In numeric mode, enters 1. In alphanumeric mode, enters P, Q, R, S, or 1.

Executes the function that is assigned to the [USR2] key.

In numeric mode, enters 2. In alphanumeric mode, enters T, U, V, or 2.

page 41

Opens a window where you can enter a code. The default code value is the last code entered.

In numeric mode, enters 3. In alphanumeric mode, enters W, X, Y, Z, or 3.

page 38

Start Auto Focus with measured distance by EDM.

In numeric mode, enters – (minus).

In alphanumeric mode, enters . (period), – (minus), or + (plus).

Displays the Power save menu, if held down for one second.

Note that Auto Focusing function must be enabled in the settings.

page 109

Displays the Bubble indicator.

In numeric mode, enters 0. In alphanumeric mode, enters *, /, =, (a space), or 0.

page 40

Key Function Details

Status bar

32 Nikon XS Series Total Station Instruction Manual

Page 49: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

Input mode indicator

The Input mode indicator only appears when you are entering points or coordinates. It shows the data input mode:

Laser pointer indicator

The icon appears while turning on the laser pointer. When the icon is displayed on the screen, the emitting power is laser class 2.

EDM measurement status

When you are taking measurements, the EDM measurement status shows the mode that is being used.

When you display observation data, the EDM measurement status shows the mode that was used when the data was collected.

Communication port status

Bluetooth enabled icon shows the Bluetooth is selected for the Port setting in the Communication menu. (See Communications, page 109.)

Input mode is numeric. Press a key on the number pad to enter the number printed on the key.

Input mode is alphabetic. Press a key on the number pad to enter the first letter printed beside the key. Press the key repeatedly to cycle through all the letters assigned to that key.

For example, to enter the letter O in alphabetic mode, press [5] three times.

Laser pointer ON.

(None) Laser pointer OFF.

Reflectorless mode

Bluetooth enabled

Nikon XS Series Total Station Instruction Manual 33

Page 50: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

Battery indicator

Shows each voltage level of the right and left internal batteries individually. When the external battery is connected with the instrument, its voltage is shown.

If the battery level becomes critically low, the following message appears:

Internal batteries (above: Left battery, below: Right battery)

External battery

Internal battery

External battery

Battery level indicator

Battery low

34 Nikon XS Series Total Station Instruction Manual

Page 51: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

LCD backlight, Laser pointer, Beep sound and Contrast adjustment

To turn on/off the 1. LCD backlight, 2. laser pointer or 3. beep sound, and to do the 4. contrast adjustment, press the illumination key and open the switch set up window shown above.

Holding down the illumination key for one second also turns on/off the LCD backlight.

• To turn on/off each function, press [ENT] when the option 1, 2, 3 or 4 is selected or directly press [1], [2], [3] or [4] numeric key.

• Press [^] or [v] to move the cursor up and down.

• In the contrast adjustment window, use [^] or [v] to adjust the contrast.

To close the window, press [ESC].

1. LCD backlight

2. Laser pointer

3. Sound

[ENT] / [4]

[ESC]

<Switch set up window > <Contrast adjustment window>

LCD backlight is OFF

LCD backlight is ON

Laser pointer is OFF

Laser pointer is ON

Sound is OFF

Sound is ON

Nikon XS Series Total Station Instruction Manual 35

Page 52: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

[DSP] key

Use the key to change the current display screen or to change display settings.

Switching between display screens

When several display screens are available, the DSP indicator appears at the top left of the screen, and the screen indicator (for example, 1/4) appears at the top right.

To move to the next available screen, press [DSP].

For example, if the DSP2 screen is currently displayed, press [DSP] to move to the DSP3 screen. The screen indicator changes from 2/4 to 3/4.

Customizing items in the Basic Measurement Screen (BMS)

To customize the items that are displayed on the DSP1, DSP2, and DSP3 screens:

1. Hold down [DSP] for one second.

2. Use the arrow keys [^], [v], [<], and [>] to highlight the item that you want to change.

3. Use the and softkeys to scroll through the list of items that can be displayed for this item.

The items that you can choose from are HA, AZ, HL, VA, V%, SD, VD, HD, Z, and (none).

4. To save your changes, press the Save softkey. Alternatively, highlight the last item for DSP3 and press [ENT]. The DSP screens show the items you have selected.

When the secondary distance unit is set, an additional screen is available. It shows the HD, VD, and SD values. For information on setting the secondary distance unit, see page 111.

The smallest unit of display for distances measured in feet-and-inches is 1/16 in. Smaller units are impractical in the field. When the actual value is greater than 99999'11''15/16, the “>” symbol is shown. If the actual distance is less than -9999'11''15/16, the “” (solid triangle) symbol is shown. This does not affect calculations. The precise value is used internally in all cases.

Except for the (none) item, you cannot display the same item on more than one line of the same screen.

The items displayed in the DSP1, DSP2, DSP3, and DSP4 screens are also used in the corresponding Stakeout screens (SO2, SO3, SO4, and SO5).

You can also customize the displayed items in Stakeout.

Header characters

The following header characters can be used in DSP screens:

• A colon (:) indicates that tilt correction is applied to the value.

• A hash symbol (#) indicates that tilt correction is off.

• An underscore (_) under the tilt correction character indicates that Sea Level Correction or Scale factor is applied.

36 Nikon XS Series Total Station Instruction Manual

Page 53: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

[MODE] key

Use the [MODE] key to change the keyboard mode for the current screen.

Changing input mode while entering points or codes

When the cursor is in a point (PT) or code (CD) field, press [MODE] to change the input mode between alphanumeric (A) and numeric (1).

The input mode indicator in the status bar changes to show the current input mode.

Quick code measurement mode

1. To activate Quick code measurement mode, press [MODE] in the BMS.

The PT field shows the default point name.

2. Press any numeric key ([0] through [9]) to start measuring and recording points.

A list of the numeric keys and their assigned feature codes appears on the right side of the screen.

For example, when you press [6], the code assigned to 6 is selected, and the instrument starts a measurement.

3. If you have set the record mode to Confirm (see Measurement settings, page 50), the Record PT screen appears after each measurement.

Do one of the following:

– To record the point, press [ENT].

– To return to the BMS, press [ESC].

4. To return to the BMS from the Qcode screen, press [MODE] or [ESC].

When the cursor is in a height (HT) field, only numeric input mode is available. Pressing [MODE] has no effect when the cursor is in a HT field.

To assign a new feature code to a numeric key, press [^] or [v] to highlight the code that you want to change. Then press the Edit softkey.

You can use the DSP softkey to change the values shown in the measurement box, in the same way as you use the [DSP] key in the Basic Measurement Screen (BMS).

Nikon XS Series Total Station Instruction Manual 37

Page 54: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

[COD] key

In the BMS, press [COD] to change the default feature code that will appear in the CD field when you record a point.

Setting the default code

When you press [COD] in the BMS, a window for entering the feature code appears.

You can use the List and Stack softkeys to enter the code.

Qcode observations

To enter the Quick code observation routine, press the Qcode softkey.

In this function, you can use the ten numeric keys to both select a feature code and shoot a point.

To change the measurement mode for the Quick code observation, press the Sett softkey.

[HOT] key

The HOT key menu is available on any observation screen. To display the HOT key menu, press [HOT].

Changing the height of the target

To change the height of the target, press [HOT] to display the HOT menu. Then either press [1] or select HT and press [ENT].

Enter the height of the target, or press the Stack softkey to display the HT stack. The HT stack stores the last 20 HT values entered.

Setting the temperature and pressure

To set the current temperature and pressure, press [HOT] to display the HOT menu. Then either press [2] or select Temp-Press and press [ENT]. Enter the ambient temperature and pressure. The ppm value is updated automatically.

In Quick code measurement, the Rec mode can only be set to Confirm or ALL.

38 Nikon XS Series Total Station Instruction Manual

Page 55: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

Selecting the target set

A target set specifies settings for the target type, the prism constant, and height of target. When you change the selected target set, all three settings are changed. You can use this function to quickly switch between two types of target, such as a reflector sheet and a prism. You can prepare up to five target sets.

Press [HOT] to display the HOT menu. Then either press [3], or select Target and press [ENT]. A list of the five target sets appears. To select a target set, either press the corresponding numeric key ([1] through [5]), or use [^] or [v] to highlight the target set in the list and press [ENT].

To change the settings defined in a target set, highlight the target set in the list. Then press the Edit softkey.

Entering a field note

To enter a field note, press [HOT] to display the HOT menu. Then either press [4], or select Note and press [ENT].

This function can be used at any time on any observation screen.

Each note can be up to 50 characters.

The note is stored as a CO record in the raw data.

To display a list of previously used notes, press the Stack softkey. The stack stores the last 20 notes.

Use [^] or [v] to highlight a note in the list. Then press [ENT] to select the note.

Setting the default point name

To change the default point name, press [HOT] to display the HOT menu. Then press [5], or select Default PT and press [ENT].

This function is available from any observation screen.

Modify the default point name for the next record.

Type Prism/N-Prism

Const –999 to 999 mm

HT –9.990 to 99.990 m

HT can be left blank in the target set. If you leave it blank, the current HT value is always applied to the measurement.

When a target set is selected, the Type and Const values are copied to both [MSR1] and [MSR2] settings, and to the measurements in Qcode. If you have specified a value for HT, this value is also copied to the current HT.

Nikon XS Series Total Station Instruction Manual 39

Page 56: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

Press [ENT] to confirm the new default point name. The new point name is appears as the default PT name on the input screen.

Bubble indicator

The bubble indicator is automatically displayed if the instrument goes out of level while the compensators are turned on, and also appears after the start up screen.

To display the bubble indicator in an observation screen, press .

The Nikon XS Series has two-axis level compensation. To turn the leveling compensators on or off, press [<] or [>]. When the leveling compensators are turned off, the text OFF appears on the screen.

If the instrument is more than ±3'30" out of level, the text OVER appears on the screen.

To return to the observation screen, press [ESC] or [ENT].

Laser plummet

Laser plummet ON/OFF

Press [ ON] to enable the laser plummet.

Press [ESC] to close the bubble indicator window.

Press [ OFF] to disable the laser plummet.

Press [Lumi.] to open the luminance adjustment window.

Press [ESC] to disable the laser plummet and close the bubble indicator window.

Laser luminance adjustment

Laser luminance can be set to 4 levels.

Press [Max.] to increase the luminance of the laser plummet.

Press [Min.] to decrease the luminance of the laser plummet.

Press [ESC] / [ENT] to return to the bubble indicator window.

The current setting of leveling compensators is indicated by header characters (:, #, :, and #) after field labels (such as HA, VA, SD, and HD) in observation screens. For more information, see Header characters, page 36.

40 Nikon XS Series Total Station Instruction Manual

Page 57: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

[USR] keys

If you use a function frequently in the field, you can assign it to the [USR1] or [USR2] key. Whenever you press a [USR] key, the function that is assigned to that key is activated directly.

The following functions can be assigned to the [USR] keys:

• Input HT

• BS Check

• Base XYZ

• Default PT

• Select Target

• Input Temp-Press

• Input Note

• The following menus, or a single function from one of these menus:

– Cogo

– O/S

– PRG

By default, Input HT is assigned to [USR1], and no function is assigned to [USR2].

Hold down the [USR] key for one second to display the list of functions that can be assigned to the key. The currently assigned function is indicated by an asterisk (*) beside the function name.

To change the function that assigned to the key, press [^] or [v] to highlight the function. Then press [ENT].

If an item on the list has an arrow (->) beside it, this item is a menu. If you highlight a menu item and then press [ENT], a sub-menu appears.

The first item on the sub-menu ends with the text [MENU]. If you select this item, the whole menu is assigned to the [USR] key.

To assign a specific function from the sub-menu, press [^] or [v] to highlight the function. Then press [ENT].

Nikon XS Series Total Station Instruction Manual 41

Page 58: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

Once you have assigned a function to a [USR] key, it is called directly whenever you press that [USR] key in the BMS.

[DAT] key

Use the [DAT] key to quickly access data in the current job from observation screens.

When you press [DAT] in the BMS or in observation screens in functions such as Stakeout, 2Pt RefLine, and Arc RefLine, the assigned data in the current job appears.

Hold down [DAT] for one second in the BMS or an observation screen to display the Select Format screen. Use this screen to change the type of data that is assigned to [DAT]. Press [1] or select DAT [MENU] to display the Data menu whenever you press [DAT].

When you select an option from this screen, the change is applied immediately, and the selected data type appears.

Press [ESC] to return to the previous observation screen.

List DisplayAvailable jobs or data appear in a list display when you do any of the following:

• view or edit data (MENU > Data)

• open the code list, point list, or Job Manager (MENU > Job)

• search for points or codes

In the list, the current cursor position is shown in reverse video (it appears as white text on a black background).

Press [^] or [v] move the cursor one line up or down.

If the Page Up icon appears, there are more pages before the current page. Press [<] to move up one page.

If the Page Down icon appears, there are more pages after the current page. Press [>] to move down one page.

To select an item from the list, move the cursor onto the item and press [ENT].

To change the type of data that is assigned to the [USR] keys in MENU > 1sec-Keys > [USR]. For more information, see [USR] key settings, page 127.

To change the type of data that is assigned to [DAT], go to MENU > 1sec-Keys > [DAT]. For more information, see [DAT] key settings, page 127.

42 Nikon XS Series Total Station Instruction Manual

Page 59: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

Inputting Data

Entering a point name or number

You can use numeric or alphanumeric names up to 16 characters long to identify points.

The default name for a new point is the last point name entered, with the last digit incremented. For example, if the last point name was A100, the default name for the next point is A101.

If the last character of the previous point name is alphabetic, the default point name is the last point name.

When the cursor is in a PT (point) field, there are several ways to specify a point, or input coordinates.

Entering an existing point

When you enter a known point name or number, the coordinates of that point are displayed briefly. A short beep sounds before the next screen appears or the next field is selected.

Entering a new point

When you input a new point name or number, a coordinate input screen appears. Enter the point’s coordinates in NE, NEZ, or elevation-only (Z) format.

Press [ENT] on the last line (the CD field) to store the point in the current job.

Pressing [ENT] without a point name

To use a point without recording the coordinates, press [ENT] in a PT field, without entering a point name.

To adjust the duration of the coordinate window display, go to MENU > Settings > Others. To leave the window open until you press [ENT], set the XYZ disp field to +ENT. For more information, see page 111.

Nikon XS Series Total Station Instruction Manual 43

Page 60: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

The input coordinates are used in the calculation. They are not saved in the database.

Specifying a wildcard (*)

If you include an asterisk (*) when you enter a point or code name, a list of points that match the entered text appears.

Use [^] or [v] to move the cursor to the point that you want to use. Then press [ENT].

If the Page Up or Page Down icons are displayed, use [<] or [>] to page up or page down the list.

When you select a point from the list, its coordinates are displayed and a beep sounds.

Recording an instant measurement

You can also input a point by recording an instant measurement. To do this, press the MSR softkey.

An observation screen appears.

Press [MSR1] or [MSR2] to start a measurement. To change the height of the target, press the HT softkey.

To go to the point recording screen when you have finished the measurement, press [ENT].

Enter the point or code name. Press [ENT].

When you move the cursor to a field, the current or default value appears in inverted text (this is the default “Replace All” input mode).

Press [>] to change the input mode to Overwrite mode and highlight the first character. Press [<] to move the cursor the end of the string.

44 Nikon XS Series Total Station Instruction Manual

Page 61: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

Entering a point from the stack

The point stack is a list of recently used points. To display the stack, press the Stack softkey when the cursor is in the PT field.

Use [^] or [v] to move the cursor to the point that you want to use. Then press [ENT].

When you return to the point input screen, the selected point name is entered in the PT field, incremented by one. For example, if you selected the A101 point, A102 appears in the PT field.

Entering a point from the point list

To display a list of existing points, press the List softkey when the cursor is in the PT field.

Use [^] or [v] to move the cursor to the point that you want to use. Then press [ENT].

When you return to the point input screen, the selected point name is entered in the PT field. You can add digits or alphabetic characters if required.

Entering a code

The CD (Code) field always defaults to the last code used. You can change the selected code on the input point screen, or you can press [COD] in the BMS. For more information, see [COD] key, page 38.

You can use numeric or alphanumeric names up to 16 characters long to identify codes.

Entering a code directly

To enter a code directly, press [MODE] to change the input mode to alphanumeric or numeric mode. Then use the keypad to enter the code.

Entering a code from the stack

The code stack is a list of recently used codes. The stack may contain up to 20 codes.

To display the stack, press the Stack softkey when the cursor is in the CD field.

Use [^] or [v] to move the cursor to the code that you want to use. Then press [ENT].

The stack shows the last 20 point names used, in chronological order from last used to first used.

Nikon XS Series Total Station Instruction Manual 45

Page 62: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

The selected code is copied to the CD field.

Entering a code from the code list

To display a list of existing codes, press the List softkey when the cursor is in the CD field.

To edit the code list, go to MENU > Data > Code List. For more information, see Editing an item in the point list or code list, page 121.

Use [^] or [v] to highlight the feature code that you want to use. Then press [ENT].

A layer has an arrow at the end of the code label. If you highlight a layer in the list and then press [ENT], the codes and layers in that layer are displayed.

When you return to the input screen, the selected code is entered in the CD field.

Advanced feature: Searching for a code by using the first characterTo find a code quickly when the code list appears, use the first-character search.

For example, to see feature codes that begin with T, use the keypad to enter the letter T. To do this, press [1] twice.

After each press of the key, the input mode field displays the selected letter. For example, if you press [1], S appears. If you quickly press [1] again, T appears. If you do not press the [1] key again, the letter T is selected.

Once you have selected a letter, the cursor moves to the feature code beginning with that letter.

If there is no code beginning with that letter, the cursor moves to the next available letter.

When the instrument is rebooted, the code stack is cleared.

Items are shown in alphabetic order.

You can also use the first character search to quickly find a code. For more information, see Advanced feature: Searching for a code by using the first character, page 46.

46 Nikon XS Series Total Station Instruction Manual

Page 63: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

Qcodes

Quick codes (Qcodes) let you shoot and record many points with feature codes in the field. You can register up to ten Quick codes. To register Qcodes, press the Edit softkey. For more information, see Quick code measurement mode, page 37.

Entering values in feet and inches

When either US Survey Feet (US-Ft) or International Feet (I-Ft) is selected as the distance unit, you can enter and display distances, HIs, HTs, and coordinate values either in decimal feet, or in feet and inches For more information, see Unit, page 110, and Others settings, page 111.

To enter values in feet and inches in an input screen, enter the elements, separated by periods (.), in the following format:

The default denominator is 16. If the denominator is 16, you do not have to enter it, and it is not displayed on the screen.

For example, if you enter [2] [.] [0] [8] [.] [5] [.] [ENT], it appears as 2'08" 5/ (2 feet, 8 and 5/16ths inches).

The following examples show how various values are entered:

Press [MODE] to switch Qcodes on or off.

Press the Edit softkey to change the Qcode. You can edit the entire code, or just the number at the end of the code.

You can still use [DSP] to change the background displays.

<Feet> [.] <Inches> [.] <Numerator> [.] <Denominator> [ENT]

(0–11) (0–15) (0–99)

To enter … Type …

65' 5 3/8" [6] [5] [.] [5] [.] [3] [.] [8] [ENT]

65' [6] [5] [ENT]

65' 5" [6] [5] [.] [5] [ENT]

65' 5 3/8" [6] [5] [.] [5] [.] [6] [ENT]

5 3/8" [0] [.] [5] [.] [3] [.] [8] [ENT] or [0] [.] [5] [.] [6] [ENT]

The numerator and denominator that you enter are automatically converted to the closest value from the following list: 0, 1/8, 1/4, 3/8, 1/2, 5/8, 3/4, 7/8, 1/16, 3/16, 5/16, 7/16, 9/16, 11/16, 13/16, 15/16.

If the denominator is 16, it is not shown on the screen.

Nikon XS Series Total Station Instruction Manual 47

Page 64: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

JobsTo record data on the instrument, you must create or open a job.

B Tip – Before you use the instrument for the first time, check the job settings.

Creating a new job

1. Press [MENU] to open the MENU screen.

2. Press [1] to open the Job Manager.

3. Press the Creat softkey to open the Create Job screen.

4. Enter the job name.

5. Press the Sett softkey to check the job settings. You cannot change a job’s settings once you have created the job.

6. Press [ENT] in the last field of the Job Sett screen to create the new job.

Creating a control job

A control job, or common file stores coordinate data that is used by several field jobs. You can create a control job in the office.

1. Press [MENU] to open the MENU screen.

2. Press [1] or select Job to open the Job Manager.

3. Move the cursor to the job that you want to use as the control job.

4. Press the FNC softkey.

If either of the messages MAX 50JOBs or Data Full appears, delete at least one existing job to free space. You cannot free space by deleting records in an existing job.

48 Nikon XS Series Total Station Instruction Manual

Page 65: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

5. Press [1] to open the Control Job screen.

6. Press the Yes softkey.

Measuring Distances

Sighting a prism reflector

C WARNING – Never look at the sun through the telescope. If you do, you may damage or lose your eyesight.

C WARNING – Precautions should be taken to ensure that persons do not look directly, with or without an optical instrument, into the beam.

C WARNING – Laser beam path should be located well above or below eye level wherever practicable.

Sight the telescope to see crosshairs at the center of the prism reflector.

Measuring distances

To take a distance measurement, press [MSR1] or [MSR2] in the Basic Measurement Screen (BMS) or in any observation screen.

While the instrument is taking a measurement, the prism constant appears in a small font.

When you enter a point name or number, the system searches in the current job first. If the point is not found in the current job, the search is automatically extended to the control job. If the point is found in the control job, the selected point is copied to the current job as a UP record.

For information on how to assemble the prism reflector, see Setting Up the Prism Reflector, page 22.

Sighting a single prism Sighting a tiltable single prism

Nikon XS Series Total Station Instruction Manual 49

Page 66: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

If the average count is set to 0, measurements are taken continuously until you press [MSR1], [MSR2], or [ESC]. Each time a measurement is taken, the distance is updated.

If the average count is set to a value from 1 to 99, the averaged distance appears after the last shot. The field name SD changes to SDx to indicate the averaged data.

Measurement settings

To view the measurement settings, hold down [MSR1] or [MSR2] for one second.

Use [^] or [v] to move the cursor between the fields. Use [<] or [>] to change the value in the selected field.

To change the height of target (HT), temperature, or pressure, press [HOT]. For more information, see [HOT] key, page 38.

Settings that relate to corrections: (T-P corr, Sea Level, C&R corr., and Map projection) are included in the job settings. These settings are job-specific. If you need to change any of these settings, you must create a new job. For more information, see Job settings, page 93, and Settings, page 106.

Field Values

Target • Prism

• N-prism

Const (prism constant) –999 mm through 999 mm

Mode • Prec0.1mm

• Prec1mm

• Norm10mm

• Fast10mm

Note that “Prec0.1mm” is the same accuracy as “Prec1 mm,” only display resolution is different.

AVE (Average count) 0 (Continuous) through 99

Rec mode One of the following:

• MSR only

• Confirm

• ALL

50 Nikon XS Series Total Station Instruction Manual

Page 67: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Getting Started 3

Target field

If the measurement is started with the Target field set to Prism, there is a dash “–” in front of the prism constant.

If the measurement is started with the Target field set to N-prism, there is a square bracket “]” in front of the prism constant.

The symbol then constantly runs from left to right over the prism constant in the display.

When an N prism measurement is taken, the icon appears in the status bar (above the battery icon).

Rec mode field

Incorrect Target settings may result in measurements outside the precision and intervals specified for the instrument.

If a prism target is aimed in the N-prism mode, the warning message "Signal High! → Try Prism Mode" will be displayed because of the excessive light reflection.

A measurement made immediately after changing the target setting may take a longer time than usual. The Target setting is used to apply better cyclic-error adjustment in distance measurement. It efficiently eliminates multipath reflection.

The Rec mode setting controls how the [MSR1] and [MSR2] keys operate in the BMS.

The MSR only setting is the default measurement mode. After a measurement, the instrument stops in the BMS and waits for you to press [ENT] before recording the point.

The Confirm setting displays the Record PT screen before data is recorded.

The ALL setting is a quick shooting and recording mode. The instrument automatically records the point using the default PT/CD. The instrument then returns to the BMS for the next measurement.

Nikon XS Series Total Station Instruction Manual 51

Page 68: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

3 Getting Started

52 Nikon XS Series Total Station Instruction Manual

Page 69: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

4

Applications 4

In this chapter:

HA Reset and Angle Operations

Station Setup

Stakeout

Program Key

Recording Measurement Data

Measuring Offsets

Nikon XS Series Total Station Instruction Manual 53

Page 70: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

HA Reset and Angle OperationsTo open the Angle menu, press [ANG] in the BMS. To select a command from this menu, either press the corresponding number key, or press [<] or [>] to highlight the command and then press [ENT].

Setting the horizontal angle to 0

To reset the horizontal angle to 0, press [1] or select 0-Set in the Angle menu. The display returns to the Basic Measurement Screen (BMS).

Entering the horizontal angle

To display the HA Input screen, press [2] or select Input in the Angle menu. Use the numeric keys to enter the horizontal angle. Then press [ENT].

Recording a foresight point after repeat angle measurement

1. To activate repeat angle measurement, press [3] or select Rept. in the Angle menu.

HR=0 appears.

2. Sight the backsight and press [ENT].

3. Sight the foresight and press [ENT].

The horizontal angle is accumulated and the value is held again.

4. To end repeat angle measurement, press [ESC].

5. When you have accumulated enough horizontal angle between the backsight and the foresight, press [MSR1] or [MSR2] to take a measurement to the foresight.

The averaged horizontal angle appears. This value is fixed until the process is finished or cancelled.

HRx is not updated even if the instrument is moved.

To enter 123°45'50", type [1] [2] [3] [.] [4] [5] [5] [0].The displayed value is rounded to the minimum angle increment.

HRx = HR ÷ N

HA = BSAz + HRx (normalized)

54 Nikon XS Series Total Station Instruction Manual

Page 71: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

6. Press [ENT] to store the foresight as a CP record. Check the PT, HT, and CD values. Then press [ENT] to record.

Face-1/Face-2 measurement

To take F1/F2 data without taking a distance measurement, press [4] or select F1/F2 in the Angle menu.

If you have already taken a distance measurement to the target, you can initiate F1/F2 averaging by flipping the telescope to the other face.

Press [ENT] on Face-2. The delta screen appears.

To record the averaged HA, VA, and SD from the F1/F2 data, press [ENT] or the OK softkey and select the CP or SS record type.

Horizontal angle hold

To hold the horizontal angle to the current value, press [5] or select Hold in the Angle menu.

To set the horizontal angle to the displayed value, press [ENT] or the Set softkey.

To cancel the process and return to the Basic Measurement Screen (BMS), press [ESC] or the Abrt softkey.

In repeat angle measurement, the HA is replaced by HR. The number of repeat angles appears at the top of the screen (for example, N= 5).

Horizontal angles can be measured up to 1999°59'59".

This function stores both raw and XYZ data as CP records, regardless of the Store DB setting.

Use Face-1/Face-2 (F1/F2) measurements to obtain maximum accuracy for measuring angles. Using F1/F2 measurements effectively cancels out mechanical constant error, except for some special errors such as the vertical axis error. For more information, see Face-1/Face-2 Measurement, page 24.

For the HA to be adjusted from a F1/F2 measurement, the Backsight must also have been measured in F1/F2 during the station setup.

Nikon XS Series Total Station Instruction Manual 55

Page 72: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Station SetupTo open the Stn Setup menu, press [STN] in the BMS.

To select a command from this menu, press the corresponding number key. Alternatively, press [<] or [>] to highlight the command and then press [ENT]. Press [^] or [v] to move up or down one page.

The last function used is highlighted.

Setting up a station with known coordinates or azimuth

1. Press [1] or select Known in the Stn Setup menu.

2. Enter a point name or number in the ST field.

– If the input point number or name is an existing point, its coordinates are displayed and the cursor moves to the HI (Height of instrument) field.

– If the point is new, a coordinate input screen appears. Enter the coordinates for the point. Press [ENT] after each field. When you press [ENT] in the CD field, the new point is stored.

– If the specified point has a code, the code appears in the CD field.

3. Enter the instrument height in the HI field and then press [ENT].

The Backsight screen appears.

4. Select an input method for defining the backsight point.

– To sight the backsight by entering coordinates, see below.

– To sight the backsight by entering the azimuth and angle, see page 58.

56 Nikon XS Series Total Station Instruction Manual

Page 73: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Sighting the backsight by entering coordinates

1. To enter coordinates for the backsight point (BS), press [1] or select Coord in the Backsight screen.

2. Enter the point name. If the point exists in the job, its coordinates are shown.

3. If you intend to take a distance measurement to the BS, enter the height of target in the HT field.

4. Sight the BS on Face-1 (F1). Press [ENT] to complete the setup.

– To record a full shot (with HA, VA, and SD values) to the BS, press [MSR1] or [MSR2].

– If you are measuring to a known coordinate BS, press [DSP] to display a QA screen. The QA screen shows the dHD and dVD values, which indicate the difference between the measured distance and the distance calculated from the known coordinates.

5. To record the station, press [ENT].

6. To finish the station setup after taking a distance measurement, press [ENT]. ST and F1 records are stored to the current job.

AZ Azimuth calculated by coordinates

Z

Y

X0

X

Xb

Y0 Yb

Backsight point(Xb, Yb, Zb)

Station point (Xi, Yi, Zi)

Inst

rum

ent h

eig

htt

Nikon XS Series Total Station Instruction Manual 57

Page 74: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Advanced feature: Measuring F1 and F2To take an angle shot and proceed to the next measurement on Face-2, press the F2 softkey.

To go directly to the Face-2 measurement after taking a distance measurement to the BS on Face-1, flip the telescope. The instrument automatically detects F1/F2.

Press [ENT] on Face-2. The delta screen appears.

To record the ST and F1/F2 records, press [ENT] or the OK softkey.

Sighting the backsight by entering the azimuth angle

1. To enter the azimuth angle to the backsight point, press [2] or select Angle in the Backsight screen.

2. The Input BS Point screen appears. If there is no point name for the BS, press [ENT] on the BS field.

3. The Input BS Angle screen appears. In the AZ field, enter the azimuth angle to the BS point.

If you press [ENT] without entering a value in the AZ field, the azimuth is automatically set to 0°00'00".

4. Sight the BS point and press [ENT]. ST and F1 records are stored in the job.

You can also use the F2 softkey for F1/F2 measurement. See Advanced feature: Measuring F1 and F2, page 58.

Backsight pointAzimuth

Station point (Xi, Yi, Zi)

Inst

rum

ent h

eigh

t

XZ

X0

Y0Y

58 Nikon XS Series Total Station Instruction Manual

Page 75: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Setting up a station using multiple point resection

A resection sets up the station using angle/distance measurements to known points.

You can use a maximum of 10 points in a resection. Measurements can be distance and angle, or angle only. Calculation starts automatically when enough measurements are taken.

You can delete poor observations and recalculate if necessary. You can also select the BS point.

1. To start the resection, press [2] or select Resection in the Stn Setup menu.

2. Enter the point name for the first observation point (PT1).

3. Enter the target height and press [ENT].

4. Sight PT1 and press [MSR1] or [MSR2].

To use the F2 softkey for F1/F2 measurement, see Advanced feature: Measuring F1 and F2, page 58.

5. To proceed to the next point, press [ENT].

6. Enter the second point (PT2) and its height of target.

7. Measure to PT2 and press [ENT].

When the instrument has enough data, it calculates the station (STN) coordinates.

If the angle between known point 1 and known point 2 (measured from the station point) is extremely acute or extremely oblique, the resulting solution will be less reliable geometrically. For geometric reliability, select known point locations (or station point locations) that are widely spaced.

Z

X0

X2

X1

X

Hei

ght 1

Hei

ght 2

Inst

rum

ent h

eig

ht

Station point (Xi, Yi, Zi)

Y1 Y0 Y2Y

Known point 1(X1, Y1, Z1)

Known point 2(X2, Y2, Z2)

Nikon XS Series Total Station Instruction Manual 59

Page 76: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

– If more than the minimum required data is available, a standard deviation screen appears.

– To take measurements to strengthen geometry of the resection, press the Add softkey. For information about the View softkey, see Advanced feature: Viewing and deleting a measurement in resection, page 61.

8. When the results are satisfactory, record the station. To do this, press [ENT] or the REC softkey.

9. Enter the height of instrument, if required. Press [ENT]. The ST field defaults to the last recorded PT + 1.

10. To change the station name, move to the ST field and edit or replace the text.

BS defaults to the first observed point.

11. To change the BS, press the Change softkey.

12. The Select BS point screen appears. Select the BS point that you want to use and press [ENT].

13. To finish the resection setup, move the cursor to the BS field and press [ENT].

If you have set Split ST to Yes, the ST field defaults to the last recorded ST value + 1. For more information, see Others settings, page 111.

The minimum data required for a resection is either three angle shots, or one angle shot and one distance shot. If you use a distance shot, the distance between the target points must be greater than the measured distance.

Stn-Z is calculated from distance-measured data. If no distances are measured, then Stn-Z is calculated using angle-only measurements to points with 3D coordinates.

60 Nikon XS Series Total Station Instruction Manual

Page 77: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Advanced feature: Viewing and deleting a measurement in resectionTo check the measurements to each known point, press the View softkey on the calculated STN (sigma or coordinate) screen.

To delete a measurement (because of large sigma values, for example), highlight the measurement data or display the detail screen for the measurement. Then press the DEL softkey. The STN coordinates are automatically recalculated.

To continue resection observations, press the Add softkey. The input screen for the next PT appears.

Setting up the station quickly without coordinates

The station point (ST) in this function defaults to a new point number. For the new point, MP (0, 0, 0) is stored as the coordinates. When the ST is manually changed to a known point name, the station is set up on the coordinates of the known point.

1. To enter Quick Station setup, press [3] or select Quick in the Stn Setup menu.

2. No default PT is assigned to the BS. Leave this field blank, or enter a BS point name.

3. The backsight azimuth (AZ) defaults to zero, but you can change this.

4. To complete the station setup, sight the BS and press [ENT].

dHA Distributed HA errors in each direction

dVD VD errors between measured distance and calculated distance

dHD HD errors between measured distance and calculated distance

ST Station point (defaults to the last recorded PT + 1, or ST + 1, depending on the Split ST setting)

HI Height of instrument

BS Backsight point (blank)

AZ Backsight azimuth (defaults to zero)

Nikon XS Series Total Station Instruction Manual 61

Page 78: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

When you press [ENT] in the AZ field, both HA and AZ are reset to the value you have entered.

Determining station elevation

1. Press [4] or select Remote BM in the Stn Setup menu.

2. The Input BM screen appears. Enter the BM point and press [ENT]. When the point is found, it appears briefly. The cursor then moves to the HT field.

3. Enter the HT and press [ENT].

4. The RBM screen appears. Sight the BM point and press [MSR1] or [MSR2].

5. To take an F1/F2 measurement, press the F2 softkey or flip the telescope to Face-2 after a distance measurement.

The updated station coordinates are displayed. You can change the HI in this screen.

6. To record the updated STN, press [ENT].

Checking and resetting the backsight direction

1. To enter the backsight (BS) check function, press [5] or select BS Check in the Stn Setup menu.

Even if both ST and BS are known points, this function does not calculate the backsight angle (AZ) automatically. To calculate the AZ between two known points (ST and BS), use Station Setup > Known. For more information, see Setting up a station with known coordinates or azimuth, page 56.

When the HI is changed, the Z coordinate is updated before the station is recorded.

You must complete a station setup before you use the Remote Benchmark function.

You must complete a station setup before you use the BS check function.

This function always refers to the backsight point from the last ST record stored in the current open job.

62 Nikon XS Series Total Station Instruction Manual

Page 79: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

2. Do one of the following:

– To reset the horizontal angle to the HA set in the last station setup sight the BS and press the Reset softkey or press [ENT].

– To cancel the process and return to the BMS, press the Abrt softkey or press [ESC].

Base XYZ function:

1. To enter the Base XYZ function, press [6] or select Base XYZ in the Stn Setup menu.

The current instrument XYZ values are shown as the default.

2. Enter the new instrument XYZ values and press [ENT].

3. Do one of the following:

– To reset the horizontal angle, enter a value in the HA field and press [ENT].

– If you do not need to reset the HA, leave the HA field blank and press [ENT].

The display returns to the BMS.

HA Current HA reading

BS The HA to the BS in the last station setup. Enter station coordinates for observations without recording data.

Base XYZ does not store a ST record, so the BS Check cannot check the backsight when you enter a station using Base XYZ.

To store raw data, use one of the other functions in the Stn Setup menu. This function does not store an ST record in the job.

You can use this function without an open job. If there is an open job when you use this function, a CO record is stored to indicate that the instrument’s base coordinates have changed.

Nikon XS Series Total Station Instruction Manual 63

Page 80: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Two-point resection along a known line

1. To enter the Known Line function, press [7] or select Known Line in the Stn Setup menu.

2. Enter a known point as P1.

If you enter a new point name, a coordinate input screen appears.

Sight P1 and press [MSR1] or [MSR2] to take a measurement. Press [ENT].

3. Choose how you want to define a known line:

– To define the line by entering P2 coordinates, press [1] or select By Coord.

– To define the line by entering the azimuth, press [2] or select By Angle.

4. If you select By Angle, the Input Angle screen appears. Enter the angle value and press [ENT].

A measurement screen appears.

5. Sight P2 and press [MSR1] or [MSR2] to take a measurement. Press [ENT].

After the measurement to P2 is completed, the coordinates of the station are calculated.

6. To record the station, press [ENT] or the REC softkey.

7. To check your measurement, press the DSP softkey. If you defined the line by entering its azimuth, HD and VD between P1 and P2 are displayed.

If you defined the line by entering the P2 coordinates, the difference of HD (dHD) and VD (dZ) between your measurement data and input coordinate data are displayed.

8. Enter the station name, the height of instrument (HI), and a feature code (CD) if required. The station name defaults to the last recorded PT + 1, or last recorded ST + 1, depending on the Split ST setting.

9. Backsight (BS) defaults to the first point (P1). To change it, highlight the BS field and then press the Change softkey.

10. To finish the setup and record the station, press [ENT] in the BS field.

64 Nikon XS Series Total Station Instruction Manual

Page 81: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Sample records

CO, Temperature:20C Pressure:1013hPa Prism:0 …

ST,9005, ,265, ,1.2350,150.40300,150.40300

F1,265,1.6040,79.0010,90.30150,89.35260,

F1,200,1.4590,50.2300,269.4035,93.50110,

CO, P1-P2 HD=122.0350 VD=0.5600

Use last station

1. To continue the last station setup in a new job or in a different existing job, open the Stn Setup menu by pressing [STN] in the Basic Measurement Screen (BMS).

2. Select Use last, or press [8].

3. Confirmation screen of the last station point appears. Press [ENT] or OK, and the last station setup will be used in the current job.

Nikon XS Series Total Station Instruction Manual 65

Page 82: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Stakeout

To display the Stakeout menu, press [S-O].

Specifying the stakeout point by angle and distance

1. To display the input screen for the distance and angle to the target, press [1] or select HA-HD in the Stakeout menu.

2. Enter the values and press [ENT].

3. Rotate the instrument until the dHA is close to 0°00'00".

4. Sight the target and press [MSR1] or [MSR2].

HD Horizontal distance from station point to stakeout point

dVD Vertical distance from station point to stakeout point

HA Horizontal angle to stakeout point

If you press [ENT] without entering HA, the current HA is used.

R

INL

OUT

CUT

FiLL

IN OUT

Heightof target

R

L

FILL

CUT

66 Nikon XS Series Total Station Instruction Manual

Page 83: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

When the measurement is completed, the differences between the target position and the stakeout point are displayed.

Once a measurement is taken, the Cut/Fill value and Z coordinate are updated as the VA is changed.

Using [DSP] to switch between display screens

Press [DSP] to switch between the Stakeout display screens. The following screens are available:

The S-O8 screen is only available if the secondary distance unit is set. For more information, see Others settings, page 111.

Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (S-O7, or S-O8 if the secondary distance unit is set), the S-O1 screen appears.

To customize the S-O2, S-O3, and S-O4 screens, hold down [DSP] for one second. For more information, see Customizing items in the Basic Measurement Screen (BMS), page 36.

To record the stakeout point, press [ENT]. PT defaults to the last recorded PT+1.

Press [ENT] to record the point.

dHA Difference in horizontal angle to the target point

R/L Right/Left (Lateral error)

IN/OUT In/Out (Longitudinal error)

CUT/FILL Cut/FilL

If you press [HOT] in any observation screen, the HOT key menu appears. You can use this menu at any time to change HT and T-P.

S-O1 S-O2 S-O3 S-O4

dHA←R←OUT↑CUT↑

HA

VA

SD

HA

VD

HD

HL

V%

HD

S-O5 S-O6 S-O7 S-O8

X

Y

Z

dX

dY

dZ

rSD

rVD

rHD

HD

VD

SD

Nikon XS Series Total Station Instruction Manual 67

Page 84: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

After recording the point, it returns to the observation screen. You can continue observation, or press [ESC] to input another angle and distance for stakeout.

Specifying the stakeout point by coordinates

1. To start a stakeout by coordinates, press [2] or select XYZ in the Stakeout menu.

2. Enter the point name that you want to stake and press [ENT].

You can also specify the point by code or radius from the instrument.

If several points are found, they are displayed in a list. Use [^] or [v] to move up and down the list. Use [<] or [>] to move up or down one page.

3. Highlight a point in the list and press [ENT].

The delta angle and the distance to the target are shown.

4. Rotate the instrument until the dHA is close to 0°00'00". Press [MSR1] or [MSR2].

5. Ask the rodman to adjust the target position. When the target is on the intended position, the displayed errors become 0.000 m (or 0.000 ft).

dHA Difference in horizontal angle to the target point

HD Distance to the target point

dHA Difference in horizontal angle to the target point

R/L Right/Left (Lateral error)

IN/OUT In/Out (Longitudinal error)

CUT/FILL Cut/FilL

To switch between display screens, press [DSP]. This function works as in the angle-distance stakeout, except that the screen counter (for example, S-O1/8) is not displayed. For more information, see Using [DSP] to switch between display screens, page 67.

Once a measurement is taken, the Cut/Fill value and Z coordinate are updated as the VA is changed.

68 Nikon XS Series Total Station Instruction Manual

Page 85: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

6. To record the point, press [ENT]. PT defaults to the specified PT + 1000.

After recording the point, the display returns to the observation screen. When you press [ESC], the display returns to the PT/CD/R input screen. If you entered the stakeout point using a single point name, the PT defaults to the last PT + 1.

If you selected a point from the list, the display returns to the list, unless all points have been selected. Press [ESC] to return to the point input screen.

Advanced feature: Specifying a stakeout list by range input1. To input points by range, press the Fr/To softkey in the PT field.

2. Enter the start point (Fr) and the end point (To). The range between Fr and To must be less than 1001 points.

If existing points are found between Fr and To, a point list appears.

To highlight a point, press [^] or [v]. To go to the stakeout observation screen, press [ENT].

If you have assigned a control job, and additional points are found in the control job, the Ctrl softkey appears under the list.

DivLine S-O

This function divides the line between the instrument and the first target by an input span number. It then guides you to stake out the points, one by one.

1. Press [3] or select DivLine S-O in the Stakeout menu.

2. Set up the baseline. To do this, sight the target on the line (the end point) and press [MSR1] or [MSR2].

Use the Add Constant field in MENU > Settings > Stakeout to specify an integer that is added to the point number being staked to generate a new number for recording the staked point. The default value is 1000. For example, when you stake out PT3 with an Add Constant of 1000, the default number for SO record is 1003. For more information, see Stakeout, page 110.

Nikon XS Series Total Station Instruction Manual 69

Page 86: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

3. Enter the total stake number in the Span total field.

The observation screen for the first stake (from the instrument) appears.

4. Sight the prism and press [MSR1] or [MSR2].

5. Use [^] or [v] to change the guide point. You can calculate and guide up to double the number of the stakes.

6. To record the point as an SO record, press [ENT].

RefLine S-O

This function allows you to stake out a point based on the Sta, O/S, and dZ to a specified line.

1. Press [4] or select RefLine S-O in the Stakeout menu.

2. Enter the first point (P1) of the line.

3. Enter the second point (P2) of the line.

4. Enter offsets to the line.

Press [ENT] in a blank field to enter the value 0.0000.

For example, if you measure to the end point at 100 m from the instrument and set the span total to 2, the following four points are calculated and can be staked:

If you press [ENT] without entering a PT name, you can enter temporary coordinates which are not recorded in the job.

Alternatively, press the MSR softkey to measure a point.

Sta Distance from P1 along the line

O/S Distance perpendicular to the line

(+) Right side of the P1-P2 line

<1/2>

HD

<2/2> <3/2> <4/2>

50 m 100 m 150 m 200 m

70 Nikon XS Series Total Station Instruction Manual

Page 87: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

5. Rotate the instrument until the dHA is close to 0°00'00".

6. Sight the target and press [MSR1] or [MSR2].

When a distance measurement is taken, the difference from the design point appears.

7. To record the point as an SO record, press [ENT].

Using [DSP] to switch between display screens

You can use [DSP] to switch between display screens. This function works as in the angle-distance stakeout. For more information, see Using [DSP] to switch between display screens, page 67.

Program KeyTo display the Programs menu, press [PRG].

Measuring distance and offset values along a specified line

1. Press [1] or select 2Pt RefLine in the Programs menu.

2. Enter the first point for the reference line. Alternatively (to enter the point by measuring), press the MsrPT softkey.

3. Enter the second point for the reference line.

(-) Left side of the P1-P2 line

dZ Difference in height from the line

Direct Measurement screen

Press the MsrPT softkey to display a direct measurement screen.

Sight the target and press [MSR1] or [MSR2]. The Record PT screen appears.

If you press [ESC] in the Record PT screen, the measured point is used but not recorded in the job.

Nikon XS Series Total Station Instruction Manual 71

Page 88: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

4. Enter an asterisk (*) in the PT field to perform a wildcard search. A list of matching points appears. Highlight a point in the list and then press [ENT].

5. Sight the prism or reflective sheet and press [MSR1] or [MSR2].

Using [DSP] to switch between display screens

Press [DSP] to switch between the Stakeout display screens. The following screens are available:

The REF5 screen is only available if the secondary distance unit is set. For more information, see Others settings, page 111.

Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (REF4 or REF5), the REF1 screen appears.

To store the point and its offset distance information, press [ENT].

Enter the point name and feature code.

You can also use this screen to change the HT value.

Sta Horizontal distance from P1 to the measure point along the P1-P2 line

O/S Horizontal offset from the P1-P2 line to the measured point

dZ Vertical offset from the P1-P2 line to the measured poin

REF1 REF2 REF3 REF4

Sta

O/S

dZ

X

Y

Z

HA

VA

SD

HA

VD

HD

REF5

HD

VD

SD

Plain view Side view

PT1

PT2

Sta O/S

Prism

PrismPT2

StaPT1

dZ

72 Nikon XS Series Total Station Instruction Manual

Page 89: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Sample records

CO, 2pt-Ref Pt:16 & Pt:13 Az:311.2932

CO, Sta= -12.6876 Offset= 1.3721 dZ= 0.0971

SS,17,1.0000,6.9202,18.4700,80.3120,15:48:48,2REF-LINE

Measuring distance and offset values on the arc-curve

1. Press [2] or select Arc RefLine in the Programs menu.

2. Enter the start of the curve point (P1) and the azimuth of its tangent line (AZ1).

3. To enter P1 by direct measurement, press the MSR softkey.

4. Choose a method to define the arc.

P2 can be any point on the tangent line that is to exit the curve.

5. In the radius (Rad) field, enter a positive value for a clockwise curve. Enter a negative value for a counterclockwise curve.

When all factors have been entered, the instrument calculates the curve.

If the curve length (Len) is too large for a circle of the given radius, it is shortened.

To … press …

switch between display screens [DSP]

Nikon XS Series Total Station Instruction Manual 73

Page 90: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Using [DSP] to switch between display screens

Press [DSP] to switch between the Stakeout display screens. The following screens are available:

The ARC5 screen is only available if the secondary distance unit is set. For more information, see Others settings, page 111.

Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (ARC4 or ARC5), the ARC1 screen appears.

To record the point, press [ENT] on any observation screen. The arc is stored in comment records.

Sample records

CO,Arc P1:583 AZ1=0.0000 P2:102

CO, AZ2=311.2932 Radius=50.0000 Length=125.6637

CO, Sta= -12.6876 Offset= 1.3721 dZ= 0.0971

SS,17,1.0000,6.9202,18.4700,80.3120,15:48:48,2REF-LINE

change HT [HOT]

record points [ENT]

ARC1 ARC2 ARC3 ARC4

Sta

O/S

dZ

X

Y

Z

HA

VA

SD

HA

VD

HD

ARC5

HD

VD

SD

To … press …

74 Nikon XS Series Total Station Instruction Manual

Page 91: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Remote distance measurement

This function measures the horizontal distance, vertical distance, and slope distance between two points.

Measuring between the current and the first point measured

1. To enter the RDM (Radial) function, press [3] or select RDM(Radial) in the Programs menu.

2. Sight the first point and press [MSR1] or [MSR2].

The distance from the station point to the first point appears.

3. Sight the second point and press [MSR1] or [MSR2]. The distances between the first and second point are displayed.

rSD Slope distance between two points

rHD Horizontal distance between two points

rVD Vertical distance between two points

rV% Percentage of grade (rVD/rHD) × 100%

rGD Vertical grade (rHD/rVD) :1

rAZ Azimuth from first point to second point

rSD Slope distance between two points

rVD Vertical distance between two points

rHD Horizontal distance between two points

1st sightingpoint

rSD

2nd sighting point

rVD

rHD

Horizontal angle 0 direction

rHA

2nd sighting point

Station point

1st sightingpoint

Nikon XS Series Total Station Instruction Manual 75

Page 92: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

4. To change display screens, press [DSP].

5. To record the distance and angle information as a comment record, press [ENT] in the 1/2 or 2/2 observation screen.

Default point numbers are displayed. You can change these point numbers. To record a note, press [ENT] in the To field.

Measuring between the current point and the immediately preceding point

1. To enter the RDM (Continuous) function, press [4] or select RDM(Cont.)in the Programs menu.

2. Follow the procedure as for a radial RDM measurement. For more information, see Measuring between the current and the first point measured, page 75.

rAZ Azimuth from first point to second point

rV% Percentage of grade (rVD/rHD) × 100%

rGD Vertical grade (rHD/rVD) :1

Data that you save in RDM functions is stored in RM records. For more information, see RM records, page 114. When you download data in Nikon RAW format, they are output as comment (CO) records.

Difference between “1:Cont.” and “2:Radial”

P1

P2

P3P4

P3P4

P2

P1

1:Cont.

(The preceding two points are2:Radial.(Calculations are made with

subject to calculation.)

reference to the first point.)

76 Nikon XS Series Total Station Instruction Manual

Page 93: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Measuring remote elevation

1. To enter the Remote Elevation Measurement function, press [5] or select REM in the Programs menu.

2. Enter the height of target.

3. Sight the target point and press [MSR1] or [MSR2].

4. Loosen the vertical clamp, and turn the telescope to aim at an arbitrary point.

The difference in elevation (Vh) appears.

You can use an REM measurement to update the height of target. Take a measurement to the prism, sight the bottom of the prism pole, and press [ENT].

A prism is requiredonly at the sighting(target) point

Station point

Sighting point

Arbitrary point

Nikon XS Series Total Station Instruction Manual 77

Page 94: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Measuring distance and offset values on the vertical plane

1. To enter the 2-Pt Reference Plane function, press [6] or select V-Plane in the Programs menu.

2. Enter two points to define the plane.

To enter the point by direct measurement, press the MsrPT softkey.

When you press the MSR softkey, a temporary observation screen appears.

3. Press [MSR1] or [MSR2]. The Record PT screen appears.

4. Enter a value in the PT and CD fields. Press [ENT].

5. Enter the second point on the vertical plane. Press [ENT].

Once the plane is defined, the calculated Sta and dZ values are updated as you move the telescope. No distance measurement is required.

Sta Horizontal distance from P1 to the target point along the baseline

dZ Vertical distance from P1 to the target point

Baseline

78 Nikon XS Series Total Station Instruction Manual

Page 95: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Using [DSP] to switch between display screens

Press [DSP] to switch between the plane display screens. The following screens are available:

Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (PLN3), the PLN1 screen appears.

To record the point, press [ENT] on any screen (V-PLN1/3 to V-PLN3/3).

Enter PT and CD. Then press [ENT].

Sample records

CO,Vertical Ref Plane Pt1:516-A1 Pt2:530

CO,Sta=68.021 dz=17.459

SS,30123-A48,1.5480,16.4020,40.4720,89.0730,14:22:47,

PLN1 PLN2 PLN3

Sta

dZ

X

Y

Z

HA

VA

Nikon XS Series Total Station Instruction Manual 79

Page 96: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Measuring distance and offset values on the slope

1. To enter the 3-Pt Reference Plane function, press [7] or select S-Plane in the Programs menu.

2. Enter three points to define the slope plane. To enter the point by direct measurement, press the MSR softkey.

If you press [ENT] in a blank field, an input screen for temporary coordinates appears. These coordinates will not be stored.

When you have entered the temporary coordinates, <Keyed-in XYZ> appears instead of the PT name.

Once the plane is defined, the calculated a and b values are updated as you move the telescope. No distance measurement is required.

If the plane is defined by two points (by selecting 2Pt), the vertical plane is the same as the plane used in the V-Pln function, but the indicating factors are Sta and dZ, not a and b. For more information, see Measuring distance and offset values on the vertical plane, page 78.

a Distance between P1 and the point that is perpendicular to the target point along the P1-P2 line

b Length of the perpendicular line from the target point to the P1-P2 line

Stn

P2 (X2,Y2,Z2)

P1 (X1,Y1,Z1)

P3 (X3,Y3,Z3)Target(X,Y,Z)b

a

80 Nikon XS Series Total Station Instruction Manual

Page 97: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Using [DSP] to switch between display screens

Press [DSP] to switch between the plane display screens. The following screens are available:

Every time you press [DSP], the next screen appears. If you press [DSP] in the last screen (PLN3), the PLN1 screen appears.

To record the point, press [ENT] on any screen (S-PLN1/3 to S-PLN3/3).

Enter PT and CD. Then press [ENT].

Sample records

CO,3ptPlane P1:1062 P2:2902 P3:1547

CO,a=31.497 b=14.239

SS,30123-A49,1.6110,0.0000,234.3210,86.0955,16:07:18,

Recording Measurement Data

Recording data from any observation screen

To record points on observation screens, press [ENT].

PT defaults to the last recorded PT + 1.

You can enter the PT name from the point list or the point stack. For more information, see Entering a point from the point list, page 45, and Entering a point from the stack, page 45.

You can also use the code list or the code stack. For more information, see Entering a code from the code list, page 46, and Entering a code from the stack, page 45.

To record the point, press [ENT] on the last field.

When recording sideshots, stakeout records and control shots from the Rept function, you can choose to store raw data only, XYZ data only, or both. For more information, see Recording, page 110.

PLN1 PLN2 PLN3

a

b

X

Y

Z

HA

VA

If HA or VA is moved after you take a measurement but before you press [ENT], the angle recorded is the angle shown when [ENT] is pressed.

In an angle-only record, SD is always recorded as 0.0000.

If the point name that you want to record already exists in the job, an error message appears. Depending on the type of existing record, you can overwrite the old record with the new data. For more information, see Recording Data, page 165.

Nikon XS Series Total Station Instruction Manual 81

Page 98: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Hold down [ENT] for one second to record the measurement as a CP record.

Outputting data to the COM port

If you press [ENT] while the [COM] icon appears in an observation screen, a line of data is output to the COM port.

Note – If [COM] appears, data is not stored to the job when you press [ENT].

The format of the output data is defined by the setting of the Ext.Comm field in MENU > Settings > Comm. For more information, see Communications, page 109.

To output data on the COM port when you press [ENT], set the Data Rec field in MENU > Settings > Rec to COM. For more information, see Recording, page 110.

82 Nikon XS Series Total Station Instruction Manual

Page 99: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Sample output records through COM port

When the Ext.Comm field is set to NIKON:

TR PN: PT8 SD:000066626 HA:003856010 VA:008048500 HT:0000061757

(TR PN: point name SD HA VA HT; when ACK is returned, PN is incremented.)

When the Ext.Comm field is set to SET:

0006662 0804806 0394324 97

(SD VA HA Chk-SUM)

Measuring Offsets

Measuring taped offsets

1. To enter the taped offset function, press [1] or select Tape in the Offset menu.

If you have not taken a distance measurement before entering this function, a temporary measurement screen appears.

2. Sight the target and press [MSR1] or [MSR2].

3. Enter offset distances from the measured point. Use [^] or [v] to move to the appropriate offset field.

You can enter any combination of taped offset distances to specify the point.

4. To go to the recording PT screen, press [ENT] in the last field.

The calculated coordinates are shown.

5. Enter a PT (and CD) value.

6. Press [ENT] to record the point.

Raw data is also recalculated, based on the taped offset value.

Left (-)

In (-)

Up (+)

Out (+)

Down (-)

Right (+)

Nikon XS Series Total Station Instruction Manual 83

Page 100: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Measuring angle offsets

1. To enter the angle offset function, press [2] or select Angle in the Offset menu.

If you have not taken a distance measurement before entering this function, a temporary measurement screen appears.

2. Sight the target and press [MSR1] or [MSR2].

3. To take the angle offset, rotate the alidade and telescope. The measured distance (HD) remains unchanged.

4. To record the offset point, press [ENT] or the OK softkey.

The XYZ data is also recalculated, based on the new angle.

Two-prism pole

1. To enter the two-prism pole function, press [3] or select 2Prism Pole in the Offset menu.

2. Sight the first prism and press [MSR1] or [MSR2].

3. Sight the second prism and press [MSR1] or [MSR2].

4. Enter the distance between the second prism and the target point. Alternatively, if you do not need QA information, you can leave the distance between the first and the second prism blank.

5. If you do enter a P1-P2 distance, the QA screen appears. Compare the entered value and the measured distance to check the accuracy of the observation.

6. To record the point, press [ENT] or the OK softkey.Sample records

SS,14,0.0000,38.9200,271.0350,89.2630,11:04:15,DITCH

CO,2Prism O/S: P1-P2= 0.5090( 0.5060) P2-Tgt= 0.5020

Note – In this sample data, 0.5090 is the measured value. 0.5060 is the entered value.

You can record an angle offset in the Basic Measurement Screen (BMS). After taking a distance measurement, rotate the alidade and/or telescope. Then press [ENT] to record the measured distance with the updated angle value. If you use this method, the dimension of the angle offset is not stored as a CO record. To store the CO record, use the O/S function.

84 Nikon XS Series Total Station Instruction Manual

Page 101: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Extending a line by horizontal angle offset

1. To enter the line extension (by HA) function, press [4] or select +Line by HA in the Offset menu.

2. Sight the first prism (or target) and press [MSR1] or [MSR2].

The display moves to the next screen.

3. Sight the second prism (or target) and press [MSR1] or [MSR2].

4. Sight the alternative place on the same vertical line as the required target point.

5. To calculate the coordinates and the raw data of the target point, press [ENT].

6. To record the point, enter a PT (and CD) value and press [ENT]. The height of target is fixed to 0.0000 for the offset point.

Sample records

SS, 40, 0.0000, 48.3304, 169.20370, 82.02470, 10:52:37

CO, PT1, 0.0000, 48.3020,169.19165, 83.58565

CO, PT2, 0.0000, 48.3155,168.54250, 85.42440

CO, O/S MSR:40 0.0000 0.0000 169.20370 87.02340

The calculated point (TGT) is stored as a SS record.

Measurements to the first and second target (P1 and P2) are stored as comment records (PT1 and PT2). The last record records the angle measurement to the ALT (vertically offset point from the actual target point).

Nikon XS Series Total Station Instruction Manual 85

Page 102: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Entering a horizontal distance after an angle-only shot

1. To enter the Input HD function, press [5] or select Input HD in the Offset menu.

2. Turn the telescope in the direction of the point that you want to store.

3. Enter the HD. Usually this is the taped distance from the instrument point.

4. Enter a PT (and CD) value and press [ENT].

The target point is calculated and recorded as an SS record.Sample records

SS,158,0.0000,77.0518,62.08380,108.06510,11:51:48,

CO, Input HD:76.1243

Calculating a corner point

1. To enter the corner point function, press [6] or select Corner in the Offset menu.

2. Take a distance measurement to the first prism (or target) on the wall. Press [MSR1] or [MSR2].

3. Sight a second point on the same wall with the first point measurement. Press [MSR1] or [MSR2].

This function is useful when the instrument is very close to the point and it is difficult to take a measurement using the EDM.

86 Nikon XS Series Total Station Instruction Manual

Page 103: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

4. Sight the first point on the second wall. Press [MSR1] or [MSR2].

5. If the two walls are at right angles, press the Calc softkey to calculate the corner point by three points.

6. If you take a measurement to a fourth point, the corner point can be calculated as the intersection of two walls (P1-P2 and P3-P4). The default elevation is given by P4.

7. Enter a PT (and CD) value. The height of target (HT) defaults to the value used in the last measurement.

8. To record the corner point, press [ENT].Sample records

SS, 58, 0.0000, 48.3304, 169.19165, 82.02470, 10:52:37, FLOOR2

CO, PT1, 1.0080, 48.3020,169.19165, 83.58565

CO, PT2, 1.0080, 48.3155,128.54250, 85.42440

CO, O/S MSR:40 0.0000 0.0000 169.20370 87.02340

The calculated corner point is stored as an SS record.

The next three or four comment records are measured points. For example:CO, Point name (fixed to PT1, PT2 etc.), HT, SD, HA, VA.

Nikon XS Series Total Station Instruction Manual 87

Page 104: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

Measuring circle offsets

1. To enter the circle center calculation function, press [7] or select Circle in the Offset menu.

If you have not taken a measurement to the circle before entering this function, a temporary measurement screen appears.

2. Sight any point on the surface of the circle and press [MSR1] or [MSR2].

3. Sight one edge of the circle and press [ENT].

4. Sight the other edge of the circle and press [ENT].

The instrument calculates and records the center of the circle. It also calculates the coordinates of the center point and the radius of the circle

5. To record the point, press [ENT] or the OK softkey.Sample records

SS,71,1.5000,37.0518,32.08380,81.06510,11:51:48,

CO, PT1, 0.0000, 0.0000,47.05350, 83.58560

CO, PT2, 0.0000, 0.0000, 29.53010, 83.58560

CO,O/S MSR:71 1.5555 36.5418 38.28360 81.06510

CO,Radius of circle 0.356

CO,Input +SD:0.0020

If you use a prism attached to the surface of the circle for the distance measurement, press the +SD softkey to eliminate the offset error (from the attached point to the measured surface of the prism) before you press [ENT].

If you have taken a distance measurement to the center of the circle, press the Calc softkey to calculate the offset using one edge angle observation.

The calculated point (center of the circle) is stored as an SS record.

The following one or two comment records are angle-measured points. For example:CO, Point name (fixed to PT1/ PT2), HT(0.0000), SD(0.0000), HA, VA.

If you press the +SD softkey before you sight Edge1, the input value is recorded at the end.

88 Nikon XS Series Total Station Instruction Manual

Page 105: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Applications 4

Extending the slope distance

1. To enter the function for extending the slope distance, press [8] or select Input dSD in the Offset menu.

If you have not taken a distance measurement before entering this function, a temporary measurement screen appears.

2. Enter the slope distance that you need to add or subtract. You can enter any value from –99.990 through +99.990 m (–328.000 through +328.000 ft).

3. To record the point, press [ENT].Sample records

SS,83,1.5000,77.0518,62.08380,81.06510,11:51:48,

CO,O/S MSR:83 1.5555 76.5518 62.08380 81.06510

Nikon XS Series Total Station Instruction Manual 89

Page 106: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

4 Applications

90 Nikon XS Series Total Station Instruction Manual

Page 107: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

5

Menu Key 5

In this chapter:

Job Manager

Cogo

Settings

Data

Communication

1sec-Keys

Calibration

Time

Removable Memory (USB Memory)

Use the MENU screen to access important functions and settings.

To display the MENU screen, press the [MENU] key.

Nikon XS Series Total Station Instruction Manual 91

Page 108: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Job ManagerUse the job manager to open, create, delete, and manage jobs. To open the Job Manager, press [1] or select Job on the MENU screen.

If there are jobs stored on the instrument, the job list appears, showing all the stored jobs. The newest job appears at the top of the list.

If there are no jobs stored, the Create Job screen appears. See Creating a new job, page 92.

Opening an existing job

The job list shows all the jobs stored on the instrument, in descending date order.

The following symbols may be used to provide extra information about jobs:

Press [^] or [v] to move up or down the job list. Press [ENT] to open the highlighted job.

When you open a job, all job settings are automatically changed to match those used in the open job.

Creating a new job

1. Press the Creat softkey in the job list.

2. Enter a job name of up to eight characters. Press [ENT].

3. Do one of the following:

– To check the job settings, press the Sett softkey.

– To create a new job using the current job settings, press [ENT] or the OK softkey.

Symbol Meaning

* Current job.

@ Control job.

! Some of the job settings are different from the current job.

? Job was created in an older DB. Older files cannot be opened in version 1.10 or later of the software.

92 Nikon XS Series Total Station Instruction Manual

Page 109: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Job settings

The following settings are set when a job is created, and cannot be changed. This ensures that the data in a job is correctly stored in the database, and that all necessary corrections are applied when you store each record.

To move between fields, press [^] or [v]. Alternatively, to move to the next field, press [ENT].

To change the setting in the selected field, press [<] or [>].

To confirm the job settings and create the job, press [ENT] in the last field (HA).

These settings are separate from other temporary settings.

Deleting a job

C CAUTION – There is no undelete function in the Job Manager. Before you press [ENT] or select DEL, make sure that the selected job is the one that you want to delete.

1. In the job list, highlight the job that you want to delete.

2. Press the DEL softkey. A confirmation screen appears.

3. Do one of the following:

– To delete the selected job, press [ENT] or the DEL softkey.

– To cancel the deletion and return to the previous screen, press [ESC] or the Abrt softkey.

After you delete a job, the display returns to the job list.

<Job Sett 1/3>

Scale Factor 0.999000 to 1.001000

T-P correction ON/OFF

Sea Level ON/OFF

C&R correction OFF/0.132/0.200

<Job Sett 2/3>

Angle unit DEG/GON/MIL

Distance unit Metre/US-Ft/I-Ft

If you select US-Ft or I-Ft, an additional settings screen appears. Use this screen to specify whether to display values in Decimal-Ft or Ft-Inch.

Temp unit °C/°F

Press unit hPa/mmHg/inHg

<Job Sett 3/3>

VA zero Zenith/Horizon/Compass

AZ zero North/South

Order NEZ/ENZ

HA Azimuth/0 to BS

Nikon XS Series Total Station Instruction Manual 93

Page 110: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Setting the control job

If you search for a point when a control job is specified, and the system cannot find the point in the current job, the control job is also searched. If the point is found in the control job, it is copied to the current job as a UP record.

A control job has the same format as a standard job. You can open and modify it like any other job, and you can use it to record any measured data.

To set the control job:

1. Highlight the job that you want to use.

2. Press the FNC softkey.

A confirmation screen appears.

3. Do one of the following:

– To set the selected job as the control job, press [ENT] or the Yes softkey.

– To cancel the process, press [ESC] or the No softkey.

Displaying job Information

To display job information, highlight the job name and then press the Info softkey.

The Information screen shows the number of records in the job, the free space, and the date when the job was created. Free space indicates how many points can be stored in the job.

To return to the job list, press any key.

Importing a job

To import a job from the USB memory stick to the instrument:

1. In the job list press the FNC softkey. The FNC screen appears.

2. Press [2] or press [v] to move the highlight to Import Job (USB->Inst.) and then press [ENT]. The USB Memory (Job) screen appears. This screen displays the job list from the detachable memory.

Note – To change the way in which the list is ordered (job name or created date), select the DSP softkey.

3. Press [v] to move the cursor to the job that you want to copy and press [ENT].

4. Verify the job name and then select the YES softkey to copy the job to the instrument. If the job contains a lot of records, the process may take a long time. A progress bar appears.

If a control job is already assigned, the newly assigned control job replaces it as the control job.

To clear the control job selected, highlight the current control job in the job list and press the Ctrl softkey. Then press [ENT] or the Yes softkey to confirm.

94 Nikon XS Series Total Station Instruction Manual

Page 111: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Select No to cancel the process.

5. When the job has been copied, do one of the following:

– To start working on the job immediately, select YES.

– To return to the menu screen, select Abrt.

Exporting a job

If you want to keep a job file for future use, you can export the job file to a USB memory stick.

To export a job:

1. Highlight the job that you want to export to the external memory device.

2. Press the FNC softkey. The FNC screen appears.

3. Press [3] or press [v] to highlight Export Job (Inst.->USB) and then press [ENT]. The Export Job screen appears.

4. Verify the job name and then select the YES softkey to export the job to the memory storage device. If the job contains many records, the process may take a long time. A progress bar appears.

Select No to cancel the process.

5. When the job export is complete, the Delete JOB screen appears. Do one of the following:

– To delete the job, select DEL.

– To cancel the process, select Abrt.

Do NOT remove the external memory device (USB memory stick) while the progress bar is displayed.

Nikon XS Series Total Station Instruction Manual 95

Page 112: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

CogoUse the Cogo menu to perform coordinate geometry (COGO) calculations. You can access this menu at any time from any observation or PT input screen.

To open the Cogo menu, press [2] or select Cogo on the MENU screen.

Calculating angle and distance between two coordinates

To open the Inverse menu, press [1] or select Inverse in the Cogo menu.

PT-PT inverse

PT-PT calculates the distance and the angle between two input points.

To calculate a PT-PT inverse:

1. Press [1] or select PT-PT in the Inverse menu.

2. The Input P1 screen appears. Enter the first point number or name. Press [ENT].

3. The Input P2 screen appears. Type the second point number/name and press [ENT]. The MSR softkey allows you to shoot the point on the spot to use it in the calculation.

The azimuth, horizontal distance, and vertical distance from the first point to the second point are displayed.

If you press [ENT] without entering a point name, a coordinate input screen appears, and you can enter coordinates. These coordinates are not stored to the database. If you want to store the point, specify a new point name.

96 Nikon XS Series Total Station Instruction Manual

Page 113: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

4. Do one of the following:

– To return to the PT input screen, press [ESC].

– To return to the COGO menu, press [ENT].

– To change the contents of the result screen, press [DSP].

3Pt angle

The 3Pt Angle function calculates the angle between two lines defined by three points.

To calculate a 3Pt angle:

1. Press [2] or select 3Pt Angle in the Inverse menu.

P1 is the base point. Two lines are to be defined by P2 and P3, both from P1.

2. The Input BasePt screen appears. Enter the point name, or use the MSR softkey to take a measurement to the point.

3. The Input direction screen appears. Enter the second point (P2) to define the baseline (P1-P2). The angle (dHA) is measured from the baseline.

4. Enter the third point (P3) to define the second line (P1-P3).

When you have entered three points, the instrument calculates the angle and distances.

5. Do one of the following:

– To return to the Inverse menu, press [ENT].

– To return to the Input BasePt screen, press [ESC].

Gd Grade (HD/VD)

V% 100/Gd

rSD Slope distance PT1 to PT2

When you press the MSR softkey, a temporary measuring screen appears. Sight the target and press [MSR1] or [MSR2] to take a measurement.

After the measurement, a recording point screen appears. To store the measured point, enter the PT, HT, and CD values and press [ENT]. To use the point without recording it, press [ESC].

Nikon XS Series Total Station Instruction Manual 97

Page 114: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Calculating and manually inputting coordinates

To enter the Input menu, press [2] or select Input in the Cogo menu. There are three functions in this menu for recording new coordinate points.

Azimuth+HD input

1. To calculate a coordinate by an angle and distance input from the base point (P1), press [1] or select AZ+HD in the Input menu.

2. The Input P1 screen appears. Enter the base point (P1). Type the point name and press [ENT].

3. The Input AZ screen appears. Enter the azimuth, horizontal distance, and vertical distance. Then press [ENT].

To enter 123°45'45", type 123.4545 and press [ENT].

4. The Input dVD screen appears. If you do not enter a value in the dVD field, the value 0.000 is used.

A recording point screen with the calculated coordinates appears. PT defaults to the last recorded PT + 1.

5. Press [ENT] to store the point.

Traverse

1. To open the Traverse (2Pt Angle) function, press [2] or select Traverse in the Input menu.

Traverse function calculates a new point based on the two defined points and angle, horizontal and vertical distances from the line defined by those two points.

2. The Input P1 screen appears. To enter P1 and P2, enter point names or take measurements to targets.

3. The Input dVD screen appears.Enter the plus-minus angle, horizontal distance, and vertical distance from the baseline defined by P1-P2.

If you do not enter a value in the dVD field, the value 0.000 is used.

4. When you press [ENT] in the dVD field, a new point is calculated. The PT name defaults to the last recorded PT + 1.

5. To record the new point and return to the point input screen, press [ENT].

98 Nikon XS Series Total Station Instruction Manual

Page 115: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

P1 (base PT) defaults to the previously recorded PT. P2 defaults to the previous P1.

Entering coordinates

To manually enter the XYZ coordinates, press [3] or select Input XYZ in the Input menu.

The PT name defaults to the last recorded PT + 1.

Enter the coordinates using the numeric keys. To move to the next field, press [ENT] or [v] in a field

To store the point as an MP record and return to the point input screen, press [ENT] in the Z field. The default PT is incremented to the next value.

Calculating area and perimeter

1. To calculate an area or perimeter, press [3] or select Area & Perim in the Cogo menu.

2. To take a measurement, enter the first point and press [ENT], or press the MSR softkey.

3. In the upper right corner of the screen, a counter indicates how many points you have entered.

To input point numbers consecutively, use the Fr/To softkey. For more information, see Advanced feature: Entering a range of points, page 100.

4. If you enter a new point name, you can enter new coordinates and record the point. If you do not want to record the point, press [ENT] without entering a value in the PT field. An XY coordinate input screen appears.

5. Continue to enter points until you have defined all the points in the lot. Then, press [v] to calculate the area and perimeter.

To continuously calculate a new point, enter +Ang, HD, and dVD from the previous bearing line. This is a convenient way to enter Traverse points.

You can record NE, NEZ, or Z-only data to the database.

The first and last points that you enter are joined to close the area.

You must enter the points in the order in which they define the lot.

You can enter up to 99 points.

Nikon XS Series Total Station Instruction Manual 99

Page 116: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

6. Press [ENT] to store the calculated values as a a comment record, or press [ESC] to return to the Cogo menu.

7. If you chose to store the area, enter a name to identify the area and then press [ENT].

Advanced feature: Entering a range of pointsTo quickly enter a sequential range of points, use the range input function. To access this function, press the Fr/To softkey in the No. 01 or No. 02 input screens.

Enter the start point name in the Fr field and the end point name in the To field. You can include letters and hyphens in the point names, but the last character must be numeric.

Press [ENT] in To field to start searching for matching points. The counter shows the number of matching points found.

When the search is complete, you are returned to the Input PT screen.

Press the Calc softkey to calculate the area and perimeter, or enter point names in the PT field.

Press [ESC] to return to the Input PT screen with the preceding point name.

When you download data in Nikon RAW format, area (AR) records are output as comment (CO) records.

100 Nikon XS Series Total Station Instruction Manual

Page 117: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Calculating coordinates from line and offset

To enter the Line & offset function, press [4] or select Line & O/S in the Cogo menu.

The Input P1 screen appears. Enter the base point (P1).

Specify the azimuth bearing. To do this, enter a value in the AZ or P2 field. P2 is a second point on the line.

Enter the horizontal distance along the baseline (Sta), the horizontal distance perpendicular to the line (O/S), and the vertical distance (dVD).

To calculate the coordinates of the point (PM), press [ENT] in the dVD field. You can change the Z coordinate here.

To record the point, press [ENT] in the CD field.

The coordinates are stored as a CC record. Line definition information and Sta, O/S, and dVD values are stored in comment (CO) records.

A negative value in the Sta field means the opposite direction along the defined bearing line.

A negative value in the O/S field is for the left-hand side of the bearing line.

Nikon XS Series Total Station Instruction Manual 101

Page 118: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Calculating coordinates using intersection functions

To enter the Intersection menu, press [3] or select Intersection in the Cogo menu. There are four functions in this menu for calculating coordinates.

Calculating a bearing-bearing intersection

A bearing-bearing intersection is the intersection point of two lines.

1. To calculate a bearing-bearing intersection, press [1] or select Brng-Brng in the Intersection menu.

2. The Input P1 screen appears. Enter the first point name and press [ENT]. Alternatively, to measure directly to the point, press the MSR softkey.

3. The Input AZ screen appears. Define the first line by azimuth.

4. To define the line by two points, press the Pts softkey. The Fr field defaults to the P1 point, but you can change the selected point. In the To field, enter or measure to the second point.

For more information about the O/S softkey, see Advanced feature: Entering angle and distance offsets, page 105.

5. Do one of the following:

– To return to the previous screen, press [ESC]. The calculated value appears in the AZ field.

– To go to the next screen, press [ENT].

6. Define the second line by two points or by P2 and AZ.

7. To calculate the coordinates of the intersection point, press [ENT] in the AZ field.

The calculated coordinates are displayed. You can input a Z coordinate if necessary.

8. Enter a value in the PT field and in the CD field.

9. To record the point, press [ENT]. Sample records

CO,Int BB P1:P10 AZ:330.54175-90.00000

CO, P2:408 AZ:100.0000+0.0000

CC,A123,,4567.3080,200.1467,-1.2056,POT

102 Nikon XS Series Total Station Instruction Manual

Page 119: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Calculating a bearing-distance intersection

1. Press [2] or select Brng-Dist in the Intersection menu.

Brng-Dist calculates the intersection point formed by one line and one distance (radius).

2. The Input P1 screen appears. Enter a point on the line.

The line can be defined by two points or by a point and an azimuth.

3. The Input P2 screen appears. Enter the second point (P2) as the center of the circle.

4. The Input HD screen appears. Enter the distance from P2.

– To define the distance (HD) by two points, press the Pts softkey.

– To calculate the coordinates of the intersection point, press [ENT] in the HD field.

5. If there are two results, the first solution appears graphically relative to the P1-P2 line. To display the second solution, press [<] or [>].

6. To record the point, press [ENT] when the required solution appears.

7. Enter a Z coordinate if necessary.

8. To move to the PT and CD fields, press [ENT].Sample records

CO,Int BD P1:4672 AZ:330.54175+0.00000

CO, P2:71 HD:100.0000

CC,504,,-839.3065,347.6682,,SIGN

Calculating a distance-distance intersection

1. Press [3] or select Dist-Dist in the Intersection menu.

2. The Input P1 screen appears. Enter the first point name and press [ENT], or press the MSR softkey to measure directly to the point.

3. The Input HD screen appears. Enter the distance from P1 and press [ENT].

4. To define the distance (HD) by two points, press the Pts softkey.

5. Enter P2 and the distance from P2 (HD).

6. To calculate the coordinates of the intersection point, press [ENT] in the HD field.

Nikon XS Series Total Station Instruction Manual 103

Page 120: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

7. Press [<] or [>] to display the second solution.

8. To record the point, press [ENT] when the required solution appears.

9. Enter a Z coordinate if necessary. Press [ENT] to move to the PT and CD fields.

Sample records

CO,Int DD P1:486 HD:330.6020

CO, P2:7 HD:100.0000

CC,505,,236.5817,50.0461,0.0000,

Calculating a point-line intersection

1. Press [4] or select Pt-Line in the Intersection menu.

2. The Input P1 screen appears. Enter the first point name and press [ENT], or press the MSR softkey to measure directly to the point.

3. The Input AZ screen appears. Enter the azimuth, or press the Pts softkey to enter another point name on the line.

4. The Input P2 screen appears. Enter the perpendicular point to the line, or press the MSR softkey to take a measurement to the point.

5. To calculate the coordinates of the intersection point, press [ENT].

If P1 and P2 are 3D points, the Z coordinate of the perpendicular point is calculated relative to the P1-P2 slope.

6. Enter PT and CD then press [ENT] to record the point.Sample records

CO,Int PtLine P1:38 AZ:90.00000+0.00000

CO, P2:506

CC,A-123,,4567.3080,200.1467,-1.2056,POT

104 Nikon XS Series Total Station Instruction Manual

Page 121: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Advanced feature: Entering angle and distance offsets1. To display the offset input screen, press the O/S

softkey.

2. In the Ang field, enter a positive value to rotate the line clockwise. Enter a negative value to rotate the line counterclockwise.

3. In the O/S field, enter a positive value to specify an offset to the right. Enter a negative value to specify an offset to the left.

Nikon XS Series Total Station Instruction Manual 105

Page 122: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

SettingsTo display the Settings menu, press [2] or select Settings on the MENU screen.

Use this menu to configure the initial job settings.

Angle

To open the Angle menu, press [1] or select Angle in the Settings menu.

Some job settings, specified in the following sections, cannot be changed once a job is created. If any of these settings are changed while a job is open, a confirmation screen appears, asking you to create a new job with the new settings, or to work with those settings without recording any data. For more information, see Settings, page 166.

VA zero Zenith/Horizon/Compass

Resolution 1"/5"/10" or 0.2 mgon/1 mgon/2 mgon

HA 0 to BS/Azimuth

The VA zero job setting cannot be changed once a job is created.

The HA job setting cannot be changed once a job is created.

When this field is set to Azimuth, the horizontal angle (HA) that appears and recorded is in Azimuth value. When this field is set to 0 to BS, HA is in HA zero to BS value.

106 Nikon XS Series Total Station Instruction Manual

Page 123: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Distance

To open the Distance menu, press [2] or select Distance in the Settings menu

Temperature and Pressure corrections

Sea Level correction

Curvature and Refraction correction

Because the surface of the earth is curved, the vertical difference (VD and Z) at the measurement point, as referenced to the horizontal plane, inevitably includes some error. This error is called curvature error. Also, because the density of the air

Scale Numeric value between 0.999000 and 1.001000

T-P corr. ON/OFF

Sea Level ON/OFF

C&R corr. OFF/0.132/0.200

The Scale, T-P corr., Sea Level, and C&R corr. job settings cannot be changed once a job is created.

SD Slope dist. (before adj.)

SD' Slope dist. (after adj.)

K Compensation coefficient

P Pressure (hPa)

T Temperature (°C)

HD Horizontal dist. (before adj.)

HD' Horizontal dist. (after adj.)

ZSTN Instrument-Z

Re 6370 km

K 275106 P

10000.013.5951 980.665×--------------------------------------------- ××

273 T+---------------------------------------------------------------------------–=

SD' 1 K1000000---------------------+

SD×=

HD'HD Re×

Re ZSTN+------------------------=

Nikon XS Series Total Station Instruction Manual 107

Page 124: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

surrounding the earth decreases with altitude, light is refracted at different rates at different altitudes. The error caused by this change in refraction is called refraction error.

Coordinate

To open the Coordinate menu, press [3] or select Coord. in the Settings menu.

HD Horizontal dist. (before adj.)

HD’ Horizontal dist. (after adj.)

VD Vertical dist. (before adj.)

VD' Vertical dist. (after adj.)

SD Slope distance

VA Vertical angle

Re 6370 km

k C&R constant (0.132 or 0.200)

Order NEZ/ENZ

Label XYZ/YXZ/NEZ(ENZ)

AZ North/South

The Order and AZ job settings cannot be changed once a job is created.

Curvature error (A A') Refraction error (A A1')P A' Horizontal

directionA

O P

A1'

A1

A'

HD' HD SD2 2VA( )sin2Re

----------------------------------- 1 k2---–

–=

VD' VD HD2

2Re

----------- 1 k–( )+=

108 Nikon XS Series Total Station Instruction Manual

Page 125: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Power saving

To open the Power Save menu, press [4], held down [AF] for one second, or select PwrSave in the Settings menu.

Auto Focus

Cont. (Continuous) Auto Focus can be set only when the EDM Unit Power Saving setting is OFF.

If the Auto Focus setting is changed to Cont. when the EDM Unit power saving setting is enabled (At once/0.1 min/0.5 min/3 min/10 min) the confirmation screen will be displayed.

Select [Yes] to change the EDM Unit power saving setting to OFF, this will also set Auto Focus to continuous mode.

Select [No] to cancel the change of Auto Focus setting to Cont. The EDM Unit power saving setting will not change.

If the EDM Unit power saving setting is enabled (changed to: At once/0.1 min/0.5 min/3 min/10 min) when the Auto Focus setting is Cont., the alert screen will be displayed and EDM Unit power saving setting will not be changed.

Communications

To open the Communication menu, press [5] or select Comm. in the Settings menu.

Main Unit OFF/5min/10min/30min

EDM Unit OFF/At once/0.1min/0.5min/3min/10min

Auto Focus Cont./Sig+Key/Key only

Cont. Select “Cont.” to continuously autofocus.

Sig+Key Select “Sig+Key” to autofocus when either a return signal from a prism target is detected, or when [AF] key is pressed.

Key only Select “Key only” to autofocus when the [AF] key is pressed.

Sleep OFF/1min/3min/5min

Ext.Comm NIKON/SET

Port Serial/Bluetooth

Baud 1200/2400/4800/9600/19200/38400 bps

Length 7/8

Parity EVEN/ODD/NONE

Stop bit 1/2

Nikon XS Series Total Station Instruction Manual 109

Page 126: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Stakeout

Press [6] or select Stakeout in the Settings menu to open the Stakeout menu.

Unit

To open the Unit menu, press [7] or select Unit in the Settings menu.

Recording

To open the Rec menu, press [8] or select Angle in the Settings menu.

Add PT Integer between 1 and 999,999

This field sets the default point number to record observed data in stakeout.

Angle DEG (Degree)

GON (GON)

MIL (Mil6400)

Distance Meter/US-Ft/I-F

If you select US-Ft or I-Ft, an additional settings screen appears. Use this screen to specify whether to display values in Decimal-Ft or Ft-Inch.

Temp °C (Celsius)

°F (Fahrenheit)

Press hPa/mmHg/inHg

The Angle, Distance, Temp, and Press job settings cannot be changed once a job is created.

Store DB RAW/XYZ/RAW+XYZ

This setting determines whether raw and/or coordinate data is stored when you record SS, CP, or SO records in the Basic Measurement Screen (BMS) or Stakeout screen.

Data Rec Internal/COM

Set this field to COM to output data on the COM port when you press [ENT] in the BMS or a Stakeout screen. The data is not stored to the job file. For more information, see Outputting data to the COM port, page 82

110 Nikon XS Series Total Station Instruction Manual

Page 127: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Security settings

To open the Security Settings menu, press [9] or select Security on the Settings menu screen.

Use the Security settings to avoid unauthorized use of the instrument, where a PIN/PUK security code can be activated and the PUK code will be displayed.

Others settings

To open the Others menu, press [9] or select Others in the Settings menu.

Change PIN To enable the security PIN Code or change the PIN Code, press [1] or select Change PIN on the Security settings menu.

If the security PIN Code is already enabled, the current PIN Code needs to be entered.

Enter the current PIN Code then press [ENT] or the OK softkey.

If you designate a new PIN Code, enter the new PIN Code, and press [ENT]. To confirm the input, enter the same PIN Code, then press [ENT] or the OK softkey.

The PIN Code is a four-digit number, e.g. “1234”.

The default of PIN Code is “0000”. By default, the security setting is not enabled and you will not be prompted to enter the PIN Code when starting the work.

Get PUK To display PUK, press [2] or select Get PUK in the Security settings menu.

If you enter an incorrect PIN Code more than ten times, you will be prompted to enter the PUK Code. When the correct PUK Code has been entered, the PIN Code will be reset to “0000”. This means that the PIN Code security will be disabled. PIN Code security can be enabled again using the Change Pin instructions above.

XYZ disp Fast/Norm/Slow/+ENT

Defines speed to move to the next screen after showing XYZ of the input PT

2nd Unit None/Meter/US-Ft/I-Ft

When the Secondary unit is set to a unit, an extra display screen is available in the BMS, stakeout observation screens, and 2-pt reference line screens. The extra screen shows the HD, VD, and SD in the secondary unit.

Split ST No/Yes

Select Yes to separate the point numbers of station points from other record type point numbers

CD Input ABC/123

Sets the default input mode when a CD field appears.

If you select US-Ft or I-Ft, an additional settings screen appears. Use this screen to specify whether to display values in Decimal-Ft or Ft-Inch.

If you set the Split ST field to Yes, an additional setting screen appears. Use this screen to specify the starting ST number.

Nikon XS Series Total Station Instruction Manual 111

Page 128: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

B Tip – To provide easier configuration for common regional settings, you can quickly configure the Nikon total station to a pre-set combination of default regional settings. For more information, see Changing Regional Configuration Presets, page 29.

B Tip – The Nikon total station supports up to 9 languages on the instrument. For more information on changing the language settings, see page 112.

DataUse the Data menu to view or edit records. To display the Data menu, press [4] on the MENU screen.

Viewing records

Viewing raw data

To show the raw data records in a list, press [1] on the Data menu screen.

When you first view the raw data, the last four raw records in the current job are displayed. Use [^] or [v] to scroll through the records.

To see detailed information for the selected records, press [ENT].

To return to the record list, press [ESC].

SS, CP, F1 records

Raw SS, CP and F1 records contain PT, HT, CD, HA, VA, and SD fields.

SS records are sideshots (topo shots). All shots from the Basic Measurement Screen (BMS) are stored as SS records.

CP records are shots taken in the Angle or Repeat menus, or in the BMS. For more information, see Recording a foresight point after repeat angle measurement, page 54, and Recording data from any observation screen, page 81.

Language Select a language from the list.

Press [<] / [>] to open the select language screen.

Press [^] / [v] to move the cursor to the desired language, and press [ENT] to select it.

A Reboot confirmation screen appears.

Press [ENT] and re-start the instrument, and the selected language will be available.

Signal Beep OFF/ON

Select ON to make a beep sound once, when getting the reflected signal from a prism target.

Owner’s Detail Up to 20 characters.

Enter your name or the name of your company. If you enter a value in this field, it appears at start-up.

You can view data at any time, even in an observation screen or while entering points.

112 Nikon XS Series Total Station Instruction Manual

Page 129: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

When the Store DB setting is set to RAW+XYZ, press [DSP] to switch between the first screen (showing HA, VA, SD, PT, and HT) and the second screen (showing X, Y, Z, PT, and CD).

Coordinates are not available in F1 records.

When you take more than one measurement to the same point and choose to overwrite the XYZ data, the old raw record becomes raw data only. As a result, only one SS(RAW) record keeps its corresponding SS(XYZ) record. Other SS(RAW) records to the same point no longer have coordinates available.

ST records

ST (station) records contain ST, HI, BS, and AZ fields.

Press [DSP] to switch between the first screen (showing ST, HI, BS, and AZ) and the second screen (showing X, Y, Z, PT, and CD).

When you assign a new ST point name in MENU > Stn Setup > Quick, the coordinates of the station is recorded as (0, 0, 0).

SO records

SO records are stakeout shots. These are shots recorded in stakeout functions.

When the Store DB setting is set to RAW+XYZ, press [DSP] to switch between the first screen (showing HA, VA, SD, PT, and HT), the second screen (showing X, Y, Z, PT, and CD), and the third screen (showing dX, dY, dZ, PT, and CD).

The dX, dY, and dZ fields store the difference between the stakeout shot’s actual position and its planned position. These fields are downloaded as comment records in Nikon RAW format.

CO records

A CO record is a comment added to the job from the system.

For example, when you change the Stn-Z using the Remote Benchmark function, or you reset the horizontal angle using the BSCheck function, the system writes a comment record.

When you input a Stn-XYZ by Base-XYZ function, the recorded station appears as a comment record.

Nikon XS Series Total Station Instruction Manual 113

Page 130: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

SY records

When you complete a station setup, a SY record is stored. This record contains the Temperature, Pressure, and Prism Constant values.

RM records

When you record measurements in RDM (Cont) or RDM (Rad), they are labeled as RM records.

Each RM record consists of two screens.

Press [DSP] to switch between the first screen (showing From, To, rHD, and rVD) and the second screen (showing rAZ, rSD, rV%, and rGD).

When you download data in Nikon RAW format, RM records are output as comment (CO) records.

AR records

An AR record stores an area and perimeter calculation.

When you download data in Nikon RAW format, AR records are output as comment (CO) records.

View coordinate data

When you press [2] or select XYZ data in the Data menu, coordinate data appears in a list, with the newest record at the bottom of the screen. Use [^] or [v] to scroll through the records. Use [<] or [>] to move up or down one page.

Press [ENT] to see more detailed information about the selected record.

UP, MP, CC, and RE records

All coordinate records contain PT, CD, X, Y, and Z fields.

UP records are uploaded point coordinates. MP records are manually input point coordinates. CC records are points calculated in Cogo, and RE records are points calculated in Resection.

The header (XYZ,YXZ,NEZ, or ENZ) depends on the Coord. Label setting in MENU > Settings > Coord. For more information, see Coordinate, page 108.

114 Nikon XS Series Total Station Instruction Manual

Page 131: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

When the Store data setting is set to RAW+XYZ or to XYZ, shots in the BMS (SS records), in various O/S functions (SS records), in 2Pt-RefLine and Arc-RefLine in PRG (SS records) and in some Stakeout functions (SO records) store coordinate records as well. The format of the data is the same as other coordinate records.

View records by station

To view records by station, press [3] or select ST->SS/SO/CP in the Data menu.

A list of all stations appears.

Use [^] or [v] to highlight the station name that you want to view. Use [<] or [>] to move up or down one page.

To view detailed information about the selected station, press [ENT].

To display all the observation data from the selected station in chronological order, press [ENT] again.

Deleting records

Deleting raw records

In the RAW screen, use [^] or [v] to highlight the record that you want to delete. Then press the DEL softkey.

A confirmation screen appears. To delete the selected record, press [ENT] or the Yes softkey.

Deleting coordinate records

In the XYZ screen, use [^] or [v] to highlight the record that you want to delete. Then press the DEL softkey.

A confirmation screen appears.

To delete the selected record, press [ENT] or the Yes softkey.

To cancel the deletion of data, press [ESC] or the No softkey.

Detailed data is as for raw data. For detailed information about each point type and format, see Viewing raw data, page 112.

If the Store DB setting is set to Both, the system also deletes the corresponding coordinate data when you delete an SS, SO, or CP record.

You can also delete raw data by pressing the DEL softkey in the detailed display screen for the record.

You can also delete coordinate data by pressing the DEL softkey in the detailed display screen for the record.

Nikon XS Series Total Station Instruction Manual 115

Page 132: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Deleting station records

In the Station screen, use [^] or [v] to highlight the record that you want to delete. Then press the DEL softkey.

A confirmation screen appears.

Press [ENT] or the Yes softkey to delete the selected record.

A reconfirmation screen appears. Press the DEL softkey to confirm deletion.

There is no undelete function on the instrument. Before you press the DEL softkey, make sure that you have selected the correct station record. You cannot press [ENT] in this screen.

All observations from the station that you selected are deleted.

Editing records

For any point record, you can edit the point name (PT), feature code (CD), height of target (HT), height of instrument (HI), backsight point (BS), and backsight azimuth (AZ).

Editing raw records

1. Do one of the following:

– In the RAW screen, highlight the record that you want to edit. Then press the Edit softkey.

– In the detailed data screen, press the Edit softkey.

2. Use [^] or [v] to highlight a field. Then modify the value in the selected field.

3. When you press [ENT] on the last line of the edit screen, a confirmation screen appears.

4. Do one of the following:

– To accept the changes and return to the data view screen, press [ENT] or the Yes softkey.

– To return to the edit screen, press [ESC] or the No softkey.

If the record that you want to delete is referred by an ST record, a confirmation message appears.

When you delete a ST record in the raw data view or the station data view, all the observation data from the station is also deleted.

You cannot edit the CD field for SO or F1 records.

You cannot edit the HA, VA, or SD values.

When you change the HT of an SS, SO, or CP measurement record, its Z coordinate is recalculated.

116 Nikon XS Series Total Station Instruction Manual

Page 133: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Editing coordinate records

You can edit PT, CD, and coordinate values in coordinate records.

1. Do one of the following:

– In the XYZ screen, use [^] or [v] to highlight the record that you want to edit. Then press the Edit softkey.

– In the detailed data screen, press the Edit softkey.

2. Use [^] or [v] to highlight a field. Then modify the value in the selected field.

3. To finish editing, press [ENT] in the CD field. A confirmation screen appears.

4. Do one of the following:

– To accept the changes and return to the data view screen, press [ENT] or the Yes softkey.

– To go back to the edit screen, press [ESC] or the No softkey.

Editing station records

Note – The system will not recalculate measurements if you change the station record. All coordinate and raw data observed from an edited station record must be recalculated in your postprocessing software.

In the RAW screen, use [^] or [v] to highlight the station record that you want to edit. Then press the Edit softkey.

You can edit any field in the ST record, but the instrument does not recalculate any measurements from this station.

Press [ENT] in the AZ field to confirm the change.

You cannot edit the coordinate record for the current station.

If you change the ST or HI values, the coordinates of observation points are not recalculated. A comment record is stored to record the change. The following example shows a comment record for a changed HI value:

CO,HI changed at ST:9012 Old HI= 1.345m

If you change the BS or AZ values, raw records are not recalculated. A comment record is stored to record the change.

Nikon XS Series Total Station Instruction Manual 117

Page 134: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Searching records

You can search for records by their type, point name, code, or by any combination of these values.

Searching raw records

In the RAW screen, press the Srch softkey to access the raw data search function.

To find a point by name, enter the name in the PT field and press [ENT] twice.

You can use the asterisk (*) as a wildcard. For example, when you enter 30* in the PT field, the search matches the points named 300, 301, 302, 3000A2, and 3010.

If more than one point matches the search criteria, the matching points are displayed in a list.

Use [^] or [v] to highlight the point you want to use. Then press [ENT] to select it.

Detailed data for the selected record appears. Press the DSP softkey to change the fields shown.

Press [ESC] to return to the list.

To search by point type, move to the Type field and use [<] or [>] to change the selected point type. The options are ALL, ST, SS, SO, CP, CO, CO(SY), and CO(RDM).

If you selected ST, SO or F1 in the Type field, you do not have to enter a value in the CD field. Press [ENT] in the PT field to start the search.

If you selected CO, CO(SY), or CO(RDM) in the Type field, you cannot enter a value in the PT or CD fields. Press [ENT] in the Type field to start the search.

If no point matches the specified criteria, an error screen appears. Press any key to return to the data screen.

118 Nikon XS Series Total Station Instruction Manual

Page 135: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Searching coordinate records

In the XYZ screen, press the Srch softkey to access the XYZ data search function.

To find a coordinate by name, enter the name in the PT field and press [ENT] twice.

You can use the asterisk (*) as a wildcard. For example, when you enter 500* in the PT field, the search matches the points named 500, 500-1, 500-A, and 5000.

If more than one point matches the search criteria, the matching points are displayed in a list.

Use [^] or [v] to highlight the point you want to use. Press [ENT] to select it.

Detailed data for the selected record appears. Press the DSP softkey to change the fields shown.

Press [ESC] to return to the list.

Entering coordinates

In the XYZ screen, press the Input softkey to display a new input point screen.

The PT field defaults to the last recorded PT + 1, but you can change the value shown.

Enter the PT and CD and then press [ENT] to enter coordinates.

Use the numeric keys to enter the coordinates. Press [ENT] or [v] in each field to move to the next field.

When you press [ENT] in the CD field, the point is stored as an MP record.

After you have recording a point, the next point input screen is shown with the updated default PT.

To search by point type, move to the Type field and use [<] or [>] to change the selected point type. The options are ALL, MP, UP, CC, and RE.

If no point matches the specified criteria, an error screen appears. Press any key to return to the data screen.

Nikon XS Series Total Station Instruction Manual 119

Page 136: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Point name list and code list

The instrument stores two list files: a list of PT names and a list of CD names. The structure and functionality of these files is the same.

• The PT name list is useful if you have to handle more than one patterns of point names in the field. For example, you may need to use points named 1, 2, 3 …, as well as points named A1, A2, A3 ….

• The Code list is a prepared list of feature codes. You can use it to store your own codes.

Press [4] or select PT name List in the Data menu to open the point name list.

Press [5] or select Code list to open the code list.

The point or code names and layers are shown in alphabetic order. Use the four softkeys to customize the list.

Deleting points, codes, or layers

In the point or code list, use [^] or [v] to highlight the item you want to delete. Then press the DEL softkey.

A confirmation screen appears. Press [ENT] or the Yes softkey to delete the item.

Press [ESC] or the No softkey to cancel the deletion.

You can record NE, NEZ, or Z-only data to the database.

You can store up to 254 points, codes, or layers in each list.

Each list entry can be up to 16 characters long.

You can use the first character search to find a point, code, or layer in the list. In the list screen, enter the first character of the name you want to find to jump to that part of the list. For more information, see Advanced feature: Searching for a code by using the first character, page 46.

To delete a whole layer, highlight the layer name in the list and press the DEL softkey. All codes and layers in the selected layer are deleted.

120 Nikon XS Series Total Station Instruction Manual

Page 137: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Editing an item in the point list or code list

Use [^] or [v] to highlight the item that you want to edit. Then press the Edit softkey.

An editing screen appears. For points, the Edit Item screen appears. It contains only the PT field. For codes, the Edit Code screen appears, containing the CD field and the REC field.

Edit the text shown and then press [ENT].

A confirmation screen appears. Press [ENT] or the Yes softkey to accept the changes and update the list.

Edit code list

• The Edit Code screen has two fields. The CD field contains the text that appears in the list screen. The REC field is optional. It contains the text that is stored in the job. If you leave the REC field blank, the value in the CD field is used.

• You can use the REC field to use familiar words or codes on the screen, but store a numeric code in the job. For example, if you set the CD field to MANHOLE and the REC field to 1155, the text MANHOLE appears on the screen, but the code 1155 is stored.

If you press the Edit softkey when a layer name appears, only the Lyr field appears. To save changes to the layer name, press [ENT] in the Lyr field.

Nikon XS Series Total Station Instruction Manual 121

Page 138: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Adding a point name

In the point list, press the Add softkey to add a new point name to the current layer.

Enter a new point name and then press [ENT].

The point name is added to the current layer and the list is updated.

Adding a code

In the code list, press the Add softkey to add a new feature code to the current layer.

Enter the feature code in the CD field. Press [MODE] to change between alphabetic and numeric input mode.

You can use the REC field to define a numeric identifier for each feature code. This is optional: If there is a value in the REC field, this value is stored. If you leave the REC field blank, the CD value is stored.

Press [ENT] to add the new code and update the code list.

Adding a layer

1. In the point or code list, press the Layer softkey.

2. Enter the name of the new layer.

3. To change between alphabetic and numeric input mode, press [MODE]. To store the new layer, press [ENT].

The new layer is added to the list in alphabetic order.

122 Nikon XS Series Total Station Instruction Manual

Page 139: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

CommunicationUse the Communication menu to download or upload data. To display the Communication menu, press [5] or select Comm. on the MENU screen.

Downloading data

To go to the download settings screen, press [1] or select Download in the Communication menu.

As each record in the current job is output from the instrument (downloaded), the current line number is updated.

After downloading is completed, you can choose to delete the current job.

To delete the current job, press [4]. To return to the Basic Measurement Screen (BMS), press [ESC] or the Abrt softkey.

Uploading coordinate data

To upload coordinate data from a computer, press [2] or select Upload XYZ in the Communication menu.

The default data format appears. To change the order of data fields, press the Edit softkey. For more information, see Advanced feature: Editing the data order for upload, page 124.

Otherwise, just press [ENT].

To change the communication settings, press the Comm softkey. The Communication screen appears. In the Port field, select Serial or Bluetooth/BT Device/USB. The port settings must match the settings used by the terminal software on the computer.

Format NIKON

SDR2x

SDR33

Data RAW

Coordinate

To display the total number of records that will be downloaded, press [ENT] in the Data field.

Press the Job softkey to go to the Job Manager screen. For more information, see Job Manager, page 92.

Nikon XS Series Total Station Instruction Manual 123

Page 140: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Use an RS-232C cable to connect the instrument to the computer. Establish communication when port setting is Bluetooth. Input 0530 if PIN is required.

The Free space field shows the number of points that can be stored.

Press [ENT] to put the instrument in receive mode. Then use the Send Text File command in the terminal program on the computer to start sending data.

As each point is received by the instrument, the value in the Records field is incremented.

Advanced feature: Editing the data order for upload1. To open the Data Fields screen, press the Edit softkey.

2. To move between the fields, press [<] or [>].

3. To change the selected item in a field, use the and softkeys. The options are PT, N, E, Z, CD, or blank.

4. To save your changes and return to the previous screen, press the Save softkey.

For example, if your original data is as follows:

and you set the data fields to PT N E CD, then the uploaded data is:

In the terminal program, set flow control to Xon/Xoff.

If you press [ESC] during data upload, the upload is cancelled and the display returns to the Communication menu. Records that were received before you pressed [ESC] are stored in the job.

The system truncates any code that is longer than 16 characters.

Duplicate points:

If the existing point is a UP, CC, or MP record, and it is not referred to by any ST or BS, it is automatically overwritten by the uploaded point. No error message appears.

1, UB, 30.000, 20.000, L1

PT=1, N=30.000, E=20.000, CD=L1

124 Nikon XS Series Total Station Instruction Manual

Page 141: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Uploading coordinates without points

You can upload data without points. If you do not include a point in the format definition, each line of data is automatically assigned the next available point number. To help you to select points in the field, make sure that you store an identifier in the CD field.

Uploading a point name list or code list

To upload a point name list via cable, press [3] or select PT List in the Communication menu.

To upload a code list, press [4] or select Code List.

Connect the RS-232C cable.

Start a terminal program on the computer.

To put the instrument into receive mode, press [ENT] or the OK softkey.

The counter is updated as each line in the list is stored.

You can store up to 254 codes or point names.

The data format cannot include duplicate items. Use PT, N, E, Z and CD once each in the data format.

To skip some items in your original file, set the corresponding field to blank.

When you upload a code list, it always replaces the existing code list on the instrument.

If a code or point name is longer than 16 characters, it is truncated.

Nikon XS Series Total Station Instruction Manual 125

Page 142: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

1sec-KeysUse the 1sec-Keys menu to configure the settings for the one-second keys, [MSR], [DSP], [USR], [S-O], and [DAT]. To access this menu, press [6] or select 1sec-Keys in the MENU screen.

[MSR] key settings

To change settings for the [MSR1] and [MSR2] keys, press [1] or select [MSR] in the 1sec-Keys menu.

There are two [MSR] keys:

• To change the settings for the [MSR1] key, press [1] or select MSR1.

• To change the settings for the [MSR2] key, press [2] or select MSR2.

Each [MSR] key has five settings.

In the Const and AVE fields, use the numeric keys to enter values. In the other fields, use [<] or [>] to change the settings.

B Tip – You can also access the settings screen by holding down [MSR1] or [MSR2] for one second.

[DSP] key settings

To change the display items in the BMS and in Stakeout observation screens, press [2] or select [DSP] in the 1sec-Keys menu.

To move the cursor, use [<], [>] , [^], or [v]. To change the display item, press either the softkey or the softkey.

To save the changes, press [ENT] at the last line of <DSP3> or press the Save softkey.

B Tip – You can also access the DSP settings screen by holding down [DSP] for one second.

126 Nikon XS Series Total Station Instruction Manual

Page 143: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

[USR] key settings

To change the functions that are assigned to the [USR1] and [USR2] keys, press [3] or select [USR] in the 1sec-Keys menu.

There are two [USR] keys. The function that is assigned to each key appears beside the key name.

• To change the settings for the [USR1] key, press [1] or select USR1.

• To change the settings for the [USR2] key, press [2] or select USR2.

In the Select Functions screen, the asterisk (*) indicates the function that is currently assigned to the key.

To highlight a function, use [^] or [v]. To assign that function to the selected [USR] key, press [ENT].

[S-O] key settings

To enter the Stakeout settings screen, press [4] or select [S-O] in the 1sec-Keys menu.

There are two Stakeout settings. For more information, see Stakeout, page 110.

[DAT] key settings

1. To change the settings for the [DAT] key, press [5] or select [DAT] in the 1sec-Keys menu.

The asterisk (*) indicates the currently selected view format.

2. To move the cursor, use [^] or [v].

3. To change the format displayed by [DAT], press [ENT].

Nikon XS Series Total Station Instruction Manual 127

Page 144: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

CalibrationUse the Calibration screen to calibrate the instrument. To open the Calibration screen, press [7] or select Calibrate on the MENU screen.

For more information, see Adjusting, page 135.

TimeUse the Date screen to set the current date and time.

1. To open the Date screen, press [8] or select Time on the MENU screen.

The current date and time settings are displayed.

2. Enter the date in Year-Month-Day format. For example, to change the date to June 18, 2008, press [2] [0] [0] [8] [ENT] [6] [ENT] [1] [8] [ENT].

If the highlighted part of the field (for example, the year) is already correct, you can just press [ENT] to use the current value. For example, if the date is already set to June 24, 2008, and you want to change the date to June 18, 2008, press [ENT] [ENT] [1] [8] [ENT].

3. To move to the Time field, press [ENT] in the Date field.

Enter the time in 24-hour format. For example, to set the time to 4:35 PM, press [1] [6] [ENT] [3] [5] [ENT].

4. Do one of the following:

– To finish setting the date and time, press [ENT] in the Minutes field.

– To cancel the input, press [ESC].

128 Nikon XS Series Total Station Instruction Manual

Page 145: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Removable Memory (USB Memory)The removable memory (external memory) shows the list of all the job files that were recorded on the USB memory stick.

Displaying the external memory files

1. Press [9] or select USB Mem. on the MENU screen. The USB Memory (Job) screen appears. This screen shows all the job files that are currently on the removable device.

2. To view other files, select the File softkey to change the list.

To return to the USB Memory (Job) screen, select the Job softkey.

Note – When you have imported the file from the USB Memory to the instrument, you can open the job on the instrument.

The job files and other files that are shown in the list are recorded in the following folders on the removable memory device (USB memory):

• Job files are stored in \NTTS\JOBS

• Other files are stored in \NTTS

Do not remove the USB memory stick while you are accessing it. Doing so may damage the files in the USB memory.

For more efficient operation it is best to use a low capacity USB stick with not many files on it.

When this message is displayed for a long time, please reduce the number of files on the removable memory as much as possible, and then retry it. A USB memory may not function in this product depending on the type. In this case, use a different type of USB memory.

Nikon XS Series Total Station Instruction Manual 129

Page 146: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

Renaming a job or file on the removable memory

Do one of the following:

• Rename a job file from the USB Memory (Job) screen.

• Rename a file from the USB Memory (file) screen.

1. Press [v] or [^] to highlight the job or file that you want to rename.

2. Press the Rnam softkey. The Change Name screen appears showing the current name of the job or file.

3. Enter a new name and then press [ENT].

Deleting a job of file from the removable memory

C CAUTION – There is no undelete function in the External Memory. Before you select DEL, make sure that the selected job is the one that you want to delete.

1. Press [v] or [^] to highlight the job or file that you want to rename.

2. Press the DEL softkey. A confirmation screen appears.

3. Do one of the following:

– To delete the selected job, press the DEL softkey.

– To cancel the deletion and return to the previous screen, press [ESC] or the Abrt softkey.

After you delete a job, the display returns to the job list.

Copying a job from the removable device

You can copy a job that is on the removable device to the instrument.

1. Press [v] or [^] to highlight the job or file that you want to copy.

2. Press [MENU] and the press [1] Import Job.

A job name may not be longer than 8 characters. A file name may not be longer than 12 characters–this includes the file extension.

You can not use a period in a job or file name.

In the Delete screen you cannot press [Ent]. You must verify the file name and then press the DEL softkey.

130 Nikon XS Series Total Station Instruction Manual

Page 147: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Menu Key 5

Changing the list view of files on the removable memory

USB Memory (Job) screen

Press the DSP softkey to view the list in alphabetical order or in date order.

USB Memory (File) screen

Press the DSP softkey to view the list in alphabetical order, in date order, or by file extension.

Nikon XS Series Total Station Instruction Manual 131

Page 148: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

5 Menu Key

132 Nikon XS Series Total Station Instruction Manual

Page 149: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

6

Checking and Adjustment 6

In this chapter:

Adjusting the Electronic Level

Checking and Adjusting the Circular Level

Checking and Adjusting the Optical/Laser Plummet

Zero Point Errors of Vertical Scale and Horizontal Angle Corrections

Auto Focus

Checking the Instrument Constant

Checking the Laser Pointer

Nikon XS Series Total Station Instruction Manual 133

Page 150: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

6 Checking and Adjustment

Adjusting the Electronic LevelAdjustment of the electronic level is done by Zero point errors of vertical scale and horizontal angle corrections. For detailed instruction, please see page 135.

Checking and Adjusting the Circular LevelOnce you have checked and adjusted the electronic level, check the circular level.

If the bubble is not in the center of the level, use the adjusting pin to rotate the three adjustment screws of circular level on the tribrach until the circular level of the instrument is centered.

Checking and Adjusting the Optical/Laser PlummetThe optical axis of the plummet must be aligned with the vertical axis of the instrument.

To check and adjust the optical/laser plummet:

1. Place the instrument on the tripod. You do not have to level the instrument.

2. Place a thick sheet of paper marked with an X on the ground below the instrument.

While you are looking through the optical plummet, adjust the leveling screws until the image of the X is in the center of the reticle mark .

For laser plummet, adjust the laser pointer to the X.

3. Rotate the alidade 180°.

If the marked image is in the same position in the center of the reticle mark, no adjustment is required

For laser plummet, if the laser pointer is on the X, no adjustment is required.

4. If the image or laser pointer is not in the same position, adjust the optical or laser plummet:

P

134 Nikon XS Series Total Station Instruction Manual

Page 151: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Checking and Adjustment 6

a. Use the supplied hexagonal wrench to turn the adjustment screws until the image of the X is in Position P. Position P is the center point of the line connecting the X and the center of the reticle mark .

b. Repeat from Step 2.For laser plummet adjustment, a cap needs to be removed.

Zero Point Errors of Vertical Scale and Horizontal Angle Corrections

Checking

1. Set up the instrument on the tripod.

2. Follow the leveling procedures described in Leveling, page 17.

3. Flip the telescope to the Face-1 position.

4. Sight a target that is within 45° of the horizontal plane.

5. Read the vertical angle from the VA1 field in the Basic Measurement Screen (BMS).

6. Rotate the instrument 180° and flip the telescope to the Face-2 position.

7. Read the vertical angle from the VA2 field.

8. Add the two vertical angles together, VA1 + VA2.

– No adjustment is required if the zero reference for vertical angles (VA zero setting) is set to Zenith, and VA1 + VA2 equals 360°.

– No adjustment is required if the zero reference for vertical angles (VA zero setting) is set to Horizon, and VA1 + VA2 is either 180° or 540°.

– An adjustment is required if VA1 + VA2 is not one of the values listed above.

Note – The difference between the vertical angle reading the relevant angle (either 360° for Zenith, or 180° or 540° for Horizon) is called the altitude constant.

Adjusting

1. To enter the calibration screen, press [MENU] and [7] Calibrat.

The Calibration screen appears.

2. To calibrate Zero Point Errors of Vertical Scale and Horizontal Angle, press [1] or select VA0/HA/Tilt in the calibration menu.

Nikon XS Series Total Station Instruction Manual 135

Page 152: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

6 Checking and Adjustment

3. The Nikon XS Series has two-axis level compensation.Take an F1 measurement to a target on the horizon. Press [ENT].

The vertical angle is shown in the V0 dir= Horiz setting.

When you have taken the measurement, the message on the bottom line changes from DO NOT TOUCH! to Turn to F2.

4. Take an F2 measurement to the same target. Press [ENT].

When the observation on F2 is completed, four parameters are displayed.

5. Do one of the following:

– To return to the first observation screen, press [ESC] or the Redo softkey.

– To set parameters on the instrument, press [ENT] or the OK softkey.

VA1 Face-1 vertical angle (tilt-off value)

HA1 Face-1 horizontal angle (tilt-off value)

X1 Face-1 X axis tilt value

Y1 Face-1 Y axis tilt value

VA2 Face-2 vertical angle (tilt-off value)

HA2 Face-2 horizontal angle (tilt-off value)

X2 Face-2 X axis tilt value

Y2 Face-2 Y axis tilt value

If ACV, ACH, X, or Y is out of range, OVER appears. Press any key to return to the first observation screen.

136 Nikon XS Series Total Station Instruction Manual

Page 153: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Checking and Adjustment 6

Auto Focus

Adjusting

1. To calibrate Auto Focus, press [2] key or select Auto Focus in the Calibration menu.

2. Sight a non-prism point that is between 2 m and 4 m away and focus manually using the focus ring.

Then press + or - softkey to fine adjust the focus, once fine adjustment is complete, press the MSR softkey.

Note – The MSR softkey appears after pressing + or - softkey, and disappears after moving the focus ring. When the MSR key is pressed, a distance measurement is started using reflectorless precise mode.

3. After measuring the near point, sight a non-prism point at least 100 m away, and follow the same focusing procedure as above: first using the focus ring, then + or - softkey for fine adjustment.

Then measure the distance by pressing MSR softkey.

4. Once both the near and far measurements are complete, the calibration constant will be calculated. If the calibration is successful, the following screen will be displayed.

Press Save softkey for saving the constant and return to the calibration menu.

Nikon XS Series Total Station Instruction Manual 137

Page 154: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

6 Checking and Adjustment

Checking the Instrument ConstantThe instrument constant is a numerical value used to automatically correct for the displacement between the mechanical and electrical centers when measuring distances. The instrument constant is set by the manufacturer before the instrument is shipped. However, to ensure the highest operational accuracy, we recommend that you check the instrument constant several times a year.

To check the instrument constant, you can either compare a correctly measured base line with the distance measured by the EDM, or follow the procedure below.

To check the instrument constant:

1. Set up the instrument at Point P, in as flat an area as possible.

2. Set up a reflector prism at Point Q, 100 m away from Point P. Make sure that you take the prism constant into account.

3. Measure the distance between Point P and Point Q (PQ).

4. Install a reflector prism on the tripod at Point P.

5. Set up another tripod at Point R, on the line between Point P and Point Q.

6. Transfer the instrument to the tripod at Point R.

7. Measure the distance from Point R to Point P (RP), and from Point R to Point Q (RQ).

8. Calculate the difference between the value of PQ and the value of RP + RQ.

9. Move the instrument to other points on the line between Point P and Point Q.

10. Repeat Step 5 through Step 9 ten times or so.

11. Calculate the average of all the differences.

The error range is within 3 mm. If the error is out of range, contact your dealer.

About 100 mP Q

P R Q

138 Nikon XS Series Total Station Instruction Manual

Page 155: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Checking and Adjustment 6

Checking the Laser PointerThe Nikon XS Series total station laser pointer is a red laser beam. The laser pointer is coaxial with the line of sight of the telescope. If the instrument is well adjusted, the red laser pointer coincides with the line of sight. External influences such as shock or large temperature fluctuations can displace the red laser pointer relative to the line of sight.

Nikon XS Series Total Station Instruction Manual 139

Page 156: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

6 Checking and Adjustment

140 Nikon XS Series Total Station Instruction Manual

Page 157: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

7

System Diagrams 7

In this chapter:

System Components

Nikon XS Series Total Station Instruction Manual 141

Page 158: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

7 System Diagrams

System Components

Figure 7.1 Measurement side

TubularCompass

Tubular compassattachment

Nikon XS Series

Connecting cable

Personal computer

Diagonal

Battery charger

Solar filter

AC adapter and plug adapter

(9 pin, USB)

eyepiece

USB memory

Low-powereyepiece

High-power eyepiece

142 Nikon XS Series Total Station Instruction Manual

Page 159: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

System Diagrams 7

Figure 7.2 Prism reflector side

Note – Nivo Series must be used with the Tribrach W30S or W30Sb.

Mini prism C

Mini prismholder

Mini prismadapter

Telescopicprism pole

Coaxial target platefor single prism

Tiltable singleprism holder

Prism adapter

Tripod for telescopic prism pole

Standard roundsingle prism C

Target pole

Triple prismholder

Tribrach adapter 15

Nikon tripod

Tribrach W30S/W30Sb

Height adjustment adapter is not used.

Nikon XS Series Total Station Instruction Manual 143

Page 160: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

7 System Diagrams

144 Nikon XS Series Total Station Instruction Manual

Page 161: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

8

Communications 8

In this chapter:

Uploading Coordinate Data

Uploading Point Lists and Code Lists

Downloading Data

Nikon XS Series Total Station Instruction Manual 145

Page 162: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

8 Communications

Uploading Coordinate Data

Settings

To configure the transmission speed and other settings, go to MENU > Settings >

Comm. For more information, see Communications, page 109.

Record format

You can upload coordinate records in the following formats:

PT , X , Y , Z , CD

PT X Y Z CD

PT , X , Y , Z

PT X Y Z

PT , X , Y , , CD

PT X Y CD

PT , X , Y , ,

PT , X , Y ,

PT , , , Z , CD

PT , , , Z

146 Nikon XS Series Total Station Instruction Manual

Page 163: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Communications 8

The record formats shown above use the following codes:

Data example

20100,6606.165,1639.383,30.762,RKBSS

20104,1165611.6800,116401.4200,00032.8080

20105 5967.677 1102.343 34.353 MANHOLE

20106 4567.889 2340.665 33.444 PT1

20107 5967.677 1102.343 34.353

20109,4657.778,2335.667,,PT2

20111,4657.778,2335.667

20113 4657.778 2335.667

20115,,,34.353,MANHOLE

20117,,,33.444

Code Description Length

PT Point number Up to 20 digits

X Actual X coordinate Variable length

Y Actual Y coordinate Variable length

Z Actual Z coordinate Variable length

CD Feature code Up to 16 characters

Nikon XS Series Total Station Instruction Manual 147

Page 164: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

8 Communications

Uploading Point Lists and Code Lists

Settings

To configure the transmission speed and other settings, go to MENU > Settings >

Comm. For more information, see Communications, page 109.

File format

PT lists and code lists use the same record format. Use the filenames POINT.LST for a PT list, and CODE.LST for a code list.

Figure 8.1 Record format for PT lists and code lists

DEFAULT{

String1 , Code1Layer2{

String2-1, Code2-1String2-2, Code2-2

}Layer3{

Layer 3-1{

String3-1-1, Code3-1-1String3-1-2, Code3-1-2

}String3-2, Code3-2String3-3, Code3-3

}String4, Code4String5, Code5String6, Code6String7, Code7

}

The first line of the file must contain the text “DEFAULT” in capital letters.

Curly brackets { } group items together under the preceding line.

For example, Layer 3-1 contains String 3-1-1 and String 3-1-2.

Layer 3 contains the five items from Layer 3-1 to String 3-3.

“String” represents characters that are displayed on the screen. “Code” represents characters that are stored in the database.

148 Nikon XS Series Total Station Instruction Manual

Page 165: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Communications 8

Data example

DEFAULT{

“STRUCTURES”{

“TREE”, “S0001”“FENCE”, “S0002”“MAIL BOX”, “S0003”“FLOWER BED”, “S0004”

}“ROADS”{

“MANHOLE”, “R0001”“CENTER LINE”{

“WHITE”, “R002-W”“YELLOW”, “R002-Y”

}“SIDEWALK”, “R0003”“CROSSING”, “R0004”“BRIDGE”, “R0005”“SIGNAL”, “R0006”“HIGHWAY STAR”, “R0007”

}“RAILWAY”{

“CROSSING”, “RW001”“STATION”, “RW002”“SIGNAL”, “RW003”“BRIDGE”, “RW004”“TUNNEL”, “RW005”

}}

Nikon XS Series Total Station Instruction Manual 149

Page 166: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

8 Communications

Downloading Data

Settings

To configure the transmission speed and other settings, go to MENU > Settings

> Comm. For more information, see Communications, page 109.

Nikon raw record formats

Coordinate records

Station records

type , pt , (pt id) , northing , easting , elevation , code

type One of the following codes:

UP Uploaded point

MP Manually input point

CC Calculated coordinate

RE Resection point

pt Point number

(pt id) (Point ID)

northing Northing of the coordinate

easting Easting of the coordinate

elevation Elevation of the coordinate

code Feature code

ST , stnpt , (stnid) , bspt , (bs id) , hi , bsazim , bsha

ST Station record identifier (fixed text)

stnpt Station point number

(stn id) (Station ID)

bspt Backsight point number

(bs id) (Backsight ID)

hi Height of instrument

bsazim Backsight azimuth

bsha Backsight horizontal angle

150 Nikon XS Series Total Station Instruction Manual

Page 167: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Communications 8

Control point records

Sideshot records

Stakeout records

CP , pt , (pt id) , ht , sd , ha , va , time , code

CP Control point record identifier (fixed text)

pt Point number

(pt id) (Point ID)

ht Height of target

sd Slope distance

ha Horizontal angle

va Vertical angle

time 24-hour time stamp

code Feature code

SS , pt , ht , sd , ha , va , time , code

SS Sideshot record identifier (fixed text)

pt Point number

ht Height of target

sd Slope distance

ha Horizontal angle

va Vertical angle

time 24-hour time stamp

code Feature code

SO , pt , (sopt) , ht , sd , ha , va , time ,

SO Stakeout record identifier (fixed text)

pt Recorded point number

(sopt) (Original number of point staked)

ht Height of target

sd Slope distance

ha Horizontal angle

va Vertical angle

time 24-hour time stamp

Nikon XS Series Total Station Instruction Manual 151

Page 168: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

8 Communications

F1 records

Comment/note records

face , pt , ht , sd , ha , va , time

face One of the following:

F1 Shot taken using Face-1 (fixed text)

Shot taken using Face-1 for Station setup (fixed text)

pt Point number

ht Height of target

sd Slope distance

ha Horizontal angle

va Vertical angle

time 24-hour time stamp

CO , text

CO Comment record identifier (fixed text)

text Comment text

152 Nikon XS Series Total Station Instruction Manual

Page 169: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Communications 8

SDR2x and SDR33 record formats

Header record

Instrument record

00NM ver 0000 datetime ang dist press temp coor 1

1–4 00NM Header record identifier (fixed text)

5–20 ver SDR download version. One of the following:

SDR20V03-05 SDR2x

SDR33V04-01 SDR33

21–24 0000 Not used

25–40 datetime Download date and time (in hours and minutes)

41 ang Angle units. One of the following:

1 Degrees

2 Gons

4 Mils

42 dist Distance units. One of the following:

1 Meters

2 Feet

43 press Pressure units. One of the following:

1 mm Hg

2 In. Hg

3 hPa

44 temp Temperature units. One of the following:

1 Celsius

2 Fahrenheit

45 coor Coordinate order. One of the following:

1 NEZ

2 ENZ

46 1 Not used

01KI1 instr serNo Instr serNo 1 zero VA 0.000 0.000 0.000

1–5 01KI1 Instrument record identifier (fixed text)

6–21, 28–43

instr Instrument make and model

22–27, 44–49

serNo Instrument serial number

50 1 Not used

51 zero VA The reference point for vertical angles. One of the following:

1 Zenith

2 Horizon

52–61, 62–71, 72–81,

0.000

0.000

0.000

Not used

Not used

Not used

Nikon XS Series Total Station Instruction Manual 153

Page 170: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

8 Communications

Station details record

Target details record

Backsight bearing details record

02KI stnpt northing easting elevation hi desc

1–4 02KI Station details record identifier (fixed text)

5–8 (2x), 5–20 (33)

stnpt Station point number

9–18 (2x), 21–36 (33)

northing Northing of station

19–28 (2x), 37–52 (33)

easting Easting of station

29–38 (2x), 53–68 (33)

elevation Elevation of station

39–48 (2x), 69–84 (33)

hi Height of instrument

49–64 (2x), 85–100 (33)

desc Station description

03NM ht

1–4 03NM Target details record identifier (fixed text)

5–14 (2x), 5–20 (33)

ht Height of target

07KI stnpt bspt bsazim ha

1–4 07KI Backsight bearing details record identifier (fixed text)

5–8 (2x), 5–20 (33)

stnpt Station point number

9–12 (2x), 21–36 (33)

bspt Backsight point number

13–22 (2x), 37–52 (33)

bsazim Backsight azimuth

23–32 (2x), 53–68 (33)

ha Horizontal angle

154 Nikon XS Series Total Station Instruction Manual

Page 171: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Communications 8

Coordinates record

Observation record

08KI pt northing easting elevation desc

1–4 08KI Coordinates record identifier (fixed text)

5–8 (2x), 5–20 (33)

pt Point number

9–18 (2x), 21–36 (33)

northing Northing of the coordinate

19–28 (2x), 37–52 (33)

easting Easting of the coordinate

29–38 (2x), 53–68 (33)

elevation Elevation of the coordinate

39–54 (2x), 69–84 (33)

desc Feature code

09MC stnpt pt sd va ha desc

1–4 09MC Observation record identifier (fixed text)

5–8 (2x), 5–20 (33)

stnpt Station point number

9–12 (2x), 21–36 (33)

pt Observed point number

13–22 (2x), 37–52 (33)

sd Slope distance

23–32 (2x), 53–68 (33)

va Vertical angle

33–42 (2x), 69–84 (33)

ha Horizontal angle

43–58 (2x), 85–100 (33)

desc Feature code

Nikon XS Series Total Station Instruction Manual 155

Page 172: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

8 Communications

Job identifier record

Note record

10NM jobid 1 incZ T&Pcorr C&Rcorr refcon sealev

1–4 10NM Job identifier record ID (fixed text)

5–8 (2x), 5–20 (33)

jobid Job name/title

Note – The following fields occur only in SDR33 format.21 1 Point ID length option

22 incZ 2D or 3D coordinates. One of the following:

1 2D

2 3D

23 T&Pcorr Atmospheric correction. One of the following:

1 Off

2 On

24 C&Rcorr Curvature and refraction correction. One of the following:

1 Off

2 On

25 refcon Refraction constant. One of the following:

1 0.132

2 0.200

26 sealev Sea level correction. One of the following:

1 Off

2 On

13NM note

1–4 13NM Note record ID (fixed text)

5–64 note Note text

156 Nikon XS Series Total Station Instruction Manual

Page 173: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Communications 8

Data examples

Nikon raw data format

CO,Nikon RAW data format V2.00

CO,EXAMPLE5

CO,Description: SAMPLE DATA OF DOWNLOAD

CO,Client:

CO,Comments:

CO,Downloaded 22-JUL-2008 18:56:10

CO,Software: Pre-installed version: 1.0.0.1

CO,Instrument: Nikon XS 5

CO,Dist Units: Metres

CO,Angle Units: DDDMMSS

CO,Zero azimuth: North

CO,Zero VA: Zenith

CO,Coord Order: NEZ

CO,HA Raw data: Azimuth

CO,Tilt Correction: VA:ON HA:ON

CO, EXAMPLE5 <JOB> Created 22-JUL-2008 07:09:21

CO,S/N:213705

MP,1,,100.000,200.000,10.000,

CO,Temp:20C Press:760mmHg Prism:0 22-JUL-2008 07:11:34

ST,1,,,,1.400,55.4500,55.4500

F1,,,,0.0000,90.0000,8:27:58

SS,3,1.200,330.706,326.027,20.320,07:13:46,SIGN

SS,4,1.250,379.193,300.847,29.084,07:14:24,TREE

SS,5,1.218,363.344,328.032,30.105,07:14:57,TREE R

SO,1003,,1.240,331.220,326.783,19.998,07:18:17,

Nikon coordinate data format

1,100.0000,200.0000,10.0000,

2,200.0000,300.0000,20.0000,

3,116.9239,216.9140,11.8425,TRAIN PLATFORM

4,126.6967,206.2596,11.2539,RAMP

11,100.0045,199.9958,10,0000,

13,116.9203,216.9113,11.7157,

14,126.6955,206.2579,10.9908,

21,100.0103,199.9958,10.0000,

31,100.0013,200.0005,10.0000,

41,100.0224,200.0331,9.9000,

43,116.9263,216,9165,11.8016,CURB

44,126.7042,206.2871,10.8193,DITCH

45,116.9266,216.9160,11.8028,

46,126.7046,206.2845,10.8213,CP POINT

Nikon XS Series Total Station Instruction Manual 157

Page 174: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

8 Communications

SDR2x raw data format

00NMSDR20V03-05 000023-Jul-2008 18:39:111211

10NMEXAMPLE6

01KI1 Nikon XS 5 000000 Nikon XS 5 00000012 0.000 0.000 0.000

13NMDownloaded 23-Jul-2008 18:39:22

13NM SAMPLE <JOB> Downloaded 23-Jul-2007 18:40:06

13NMSoftware: Pre-install version: 3.3.0.1

13NMInstrument: Nikon XS 5

13NMDist Units: Metres

13NMAngle Units: Degrees

13NMZero azimuth: North

13NMZero VA: Horizon

13NMCoord Order: NEZ

13NMClient:

13NMDescription:

13NMTilt Correction: VA:ON HA:ON

13NM EXAMPLE6 <JOB> Created 23-Jul-2008 07:09:21

08KI0001100.000 200.000 10.000

08KI0002200.000 300.000 20.000

02KI0001100.000 200.000 10.000 0.100

07KI0001000245.0000 0.0000

13F100000002<null> <null> 0.0000

13F200000002<null> <null> 179.9639

13NMBS Check HA:359.3525 Reset to HA: 0.0000 07:21:41

13F10000000323.990 4.1694 0.0000

13F20000000323.990 175.8403 180.0028

03NM0.000

13F10001000323.990 4.1653 359.9833 MAIN PLATFORM

13F10001000427.445 2.4097 328.1958 RAMP

13NMStart of 2-Pt Resection

13F10000000427.445 2.4097 0.0000

13F10000000323.991 4.1542 31.8042

13F10000000427.430 1.8583 121.4306

13F10000000323.976 3.8625 153.2306

08KI0011100.005 199.996 10.000

02KI0011100.005 199.996 10.000 0.100

07KI0011000344.9980 0.0000

158 Nikon XS Series Total Station Instruction Manual

Page 175: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Communications 8

SDR2x coordinate data format

00NMSDR20V03-05 000023-Jul-2008 18:40:111211

10NMEXAMPLE6

01KI1 Nikon XS 5 000000 Nikon XS 5 00000012 0.000 0.000 0.000

13NM 080926-2 <JOB> Downloaded 08-Oct-2008 18:40:06

13NM SAMPLE <JOB> Downloaded 23-Jul-2007 18:40:06

13NMSoftware: Pre-install version: 3.3.0.1

13NMInstrument: Nikon XS 5

13NMDist Units: Metres

13NMAngle Units: Deqrees

13NMZero azimuth: North

13NMZero VA: Horizon

13NMProjection correction: OFF

13NMC&R correction: OFF

13NMSea level correction: OFF

13NMCoord Order: NEZ

13NMClient:

13NMDescription:

13NMTilt Correction: VA:OFF HA:OFF

13NM EXAMPLE6 <JOB> Created 23-Jul-2008 07:09:21

13NMPrism constant: 0

08KI0001100.000 200.000 10.000

08KI0002200.000 300.000 20.000

13NMBacksight Check to Pt:2 HA:359.3525 07:21:39

13NMBacksight Pt:2 Reset to HA: 0.0000 07:21:41

08KI0003116.924 216.914 11.843 MAIN PLTFORM

08KI0004126.697 206.260 11.254 RAMP

13NMStart of 2-Pt Resection

08KI0011100.005 199.996 10.000

Nikon XS Series Total Station Instruction Manual 159

Page 176: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

8 Communications

160 Nikon XS Series Total Station Instruction Manual

Page 177: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

C H A P T E R

9

Error Messages 9

In this chapter:

Cogo

Communications

Data

Job Manager

Programs

Recording Data

Searching

Settings

Stakeout

Station Setup

System Error

Nikon XS Series Total Station Instruction Manual 161

Page 178: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

9 Error Messages

Cogo

NO Result 90.1

The system was unable to calculate an area because points were not entered in the correct order.

Press any key to return to the Cogo menu. Then enter the points in the correct order.

Same Coordinate 90.2

The point or coordinate that you entered is identical to the previous input point.

Press any key to return to the point input screen. Then use a different point.

XY-coordinate is required 90.3

The input point does not have XY (NE) coordinates.

Press any key to return to the point input screen. Then enter a point that has X and Y coordinates.

CommunicationsIf an error is detected during uploading of data, the instrument aborts the upload process and displays one of the following messages.

Check Data 90.4

There are errors in the uploaded data. The uploaded data contains errors, such as an alphabetic character in a coordinate field.

Press any key. Then check the specified line in the data.

DUPLICATE PT 90.5

The uploaded data contains a duplicate PT.

Press any key. Then check the specified point in the data.

B Tip – If the existing point is a UP, CC, or MP record, and is not referred by ST or BS, then it will be overwritten by the uploaded record. No error message appears.

PT MAX20 chars 90.6

The uploaded data contains a PT with a name or number that is longer than 20 digits.

Press any key. Then check the specified line in the data.

XYZ OVERRANGE 90.7

The uploaded data contains a coordinate that is longer than 13 digits.

Press any key. Then check the specified line in the data.

162 Nikon XS Series Total Station Instruction Manual

Page 179: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Error Messages 9

Data

Can't Edit Current ST 90.8

You have tried to edit the current ST.

Note – You cannot edit the current ST. However, old ST records can be edited. No recalculation can be performed on the instrument.

Press any key to return to the code/layer name input screen.

Can't Edit ST/BS refer to this PT 90.9

You have tried to edit a coordinate that the current ST or BS refers to. You cannot change a coordinate if the current ST or BS refers to it.

Press any key to return to the Data view screen.

Can't Edit XYZ from measurement 90.10

You have tried to change the coordinates of an SO, SS, or CP record. You cannot change the coordinates of an SO, SS, or CP record.

Press any key to return to the previous screen.

DELETE Stn-XYZ 90.11

You have tried to delete a coordinate record that the current ST or BS refers to. You must confirm that you want to delete a coordinate record that the current ST or BS refers to.

To ... Press ...

delete XYZ the DEL softkey

return to the previous screen without deleting XYZ [ESC] or the Abrt softkey

Nikon XS Series Total Station Instruction Manual 163

Page 180: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

9 Error Messages

Job Manager

Cannot Assign 90.12

You have tried to set the current job as the control file.

Press any key to return to the previous screen. Then select a different job.

Can't Create 90.13

There is no space available to create a job or record a point.

Press any key to return to the Job Manager. Then use the DEL softkey to delete old jobs.

Existing Job 90.14

You have entered an existing job name for a new job.

Press any key and then change the name for the new job.

MAX 50Jobs 90.15

You are trying to create a new job when the maximum number of jobs (50) is already stored.

Press any key to return to the Job Manager. Then use the DEL softkey to delete old jobs.

Programs

NO Stn Setup 90.16

You did not perform a station setup or BS check before entering the Programs function.

B Tip – Selecting Continue does not resume the last ST record. You should only use the Continue option if you are sure that the previous ST coordinates and the current HA orientation are correct. Otherwise, records in the Programs function may not be correct.

XY&Z coordinate are required 90.17

Three-dimensional coordinates are required in S-Plane function.

Press any key to return to the point input screen. Then enter a three-dimensional point.

To ... Press ...

go to the Stn Setup menu [2] or select Stn Setup

return to the BMS [ESC]

go to the Programs menu [1] or select Continue

164 Nikon XS Series Total Station Instruction Manual

Page 181: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Error Messages 9

Recording Data

DATA FULL 90.18

The data storage is full.

Press any key to return to the Basic Measurement Screen (BMS). Then:

DUPLICATE PT 90.19

The input PT you are trying to record already exists in the current job. An existing coordinate record cannot be overwritten by measured data.

Press any key to return to the point input screen. Change PT.

Duplicate PT 90.20

The input PT you are trying to record already exists in the current job as an SS, SO, or CP record. An existing SS, SO, or CP record can be overwritten by measured data.

No Open Job 90.21

No job is open.

NO Stn Setup 90.22

There is no station record in the current job, or a station setup or BS check has not been done since the program was rebooted.

To ... Go to ...

delete unnecessary data MENU > Data

delete jobs MENU > Job

To ... Press ...

return to the PT input screen [ESC] or the Abrt softkey

record RAW data and update XYZ data the XYZ softkey

record RAW data only the RAW softkey

To ... Press ...

open the job list, if there are existing jobs [1] or select Select job

create a new job [2] or select Create job

return to the previous screen [ESC]

To ... Press ...

continue recording [1] or select Continue. If there is already an ST record in the job, the message CO, Use current orientation appears.

go to the Stn Setup menu [2] or select STN Setup

return to the previous screen [ESC]

Nikon XS Series Total Station Instruction Manual 165

Page 182: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

9 Error Messages

OVER RANGE 90.23

You are trying to record a coordinate with more than 13 digits

Press any key to return to the previous screen. Then check the current ST coordinate.

Searching

PT Not Found 90.24

There is no point that matches the criteria you entered.

Press any key to return to the point input screen.

This message may appear in any function where the PT/CD is input, such as Station Setup or Stakeout.

Settings

Job Settings will be changed 90.25

You have changed one or more of the following job settings:

• VA zero or HA in the Angle screen (see Angle, page 106)

• Scale, T-P, Sea Lvl, or C&R in the Distance screen (see Distance, page 107)

• Coord or Az Zero in the Coordinates screen (see Coordinate, page 108)

• Angle, Dist, Temp, or Press in the Unit screen (see Unit, page 110)

Note – To record a point using the new settings, create a new job using the new settings.

Stakeout

Input Error 90.26

The point name style used in the Fr field is not the same as the style used in the To field. For example, the Fr field style is 1, and the To field style is A200.

Press any key to return to the Fr/To input screen. Then re-enter the point name, using the same naming style in both fields.

To ... Press ...

discard the changes to the job settings [ESC] or the Abrt softkey. The current job remains open.

close the current job and save the changes to the job settings

[ENT] or the OK softkey

166 Nikon XS Series Total Station Instruction Manual

Page 183: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

Error Messages 9

NO Stn Setup 90.27

You did not perform a station setup or BS check before entering the Stakeout function.

B Tip – Selecting Continue does not resume the last ST record. You should only use the Continue option if you are sure that the previous ST coordinates and the current HA orientation are correct. Otherwise, records in the Stakeout function may not be correct.

Station Setup

Calc ST Failed Need additional PT 90.28

Calculating ST failed in resection. This message may appear after you have deleted a point the View shots screen.

Press any key to return to the PT input screen. Take another shot to calculate the ST coordinate.

Same Coordinate 90.29

The input PT or coordinate is identical to the current station in STN/1:Known, or the same coordinate or point name/number is found in Resection.

Press any key to return to the PT input screen. Then use a different PT.

Space LOW 90.30

There is not enough space to record a station when you start any of the Station Setup functions.

XY-coordinate is required 90.31

The input point for ST/BS does not have N/E coordinates.

Press any key to return to the PT input screen. Then use a PT that has N/E coordinates.

To... Press ...

go to the Stn Setup menu [2] or select Stn Setup

return to the Basic Measurement Screen (BMS)

[ESC]

go to the Stakeout menu [1] or select Continue

To ... Press ...

return to the BMS press [ESC] or the Abrt softkey. Use the DEL softkey in Job Manager to delete old jobs.

continue press [ENT] or the OK softkey. You may not be able to record the whole process.

Nikon XS Series Total Station Instruction Manual 167

Page 184: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

9 Error Messages

Z-coordinate is required 90.32

The input point for Benchmark does not have a Z coordinate.

Press any key to return to the PT input screen. Then use a PT that has a Z coordinate.

System Error

=SYSTEM ERROR= 90.33

The system has detected an internal error that is related to the lower-level system.

Press any key to turn the instrument off. The system will reboot when this error is reported. If you still have more points to shoot in the site, turn the instrument on and repeat the open a job and station setup procedures.

Data stored before this error will be kept safely in the Job file.

If the error appears frequently, please contact your dealer or Trimble Support and report the message that appears below the =SYSTEM ERROR= line.

168 Nikon XS Series Total Station Instruction Manual

Page 185: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the
Page 186: Nikon XS Series Total Station Instruction Manual...Nikon XS Series Total Station Instruction Manual vii Safety C WARNING – Do not cover the battery charger and AC adapter while the

© 2017, Trimble Inc. All rights reserved. Trimble is a trademark of Trimble Inc. registered in the United States Patent and Trademark Office and other countries. Nikon is a registered trademark of Nikon. All other trademarks are the property of their respective owners. PN C300E

CONTACT DETAILS10368 Westmoor Drive, Suite #100Westminster, Colorado 80021USA

888-477-7516 (Toll Free)1-720-587-4700 Phone

www.spectraprecision.com

For sales information and dealer locator:[email protected]

www.trimble.com