NFPA Firefighter 1 Skills Verification Task Book

40
Central Valley Fire District/Belgrade City Fire Department NFPA Firefighter 1 Skills Verification Task Book July 2014 Based on IAFC Fundamentals of Fire Fighter Skills, Third Edition, Meeting the requirements of NFPA 1001, 2008 edition Task Book Assigned to: Name: ____________________________________________________________ ___________________ Skill Book Initiated: __________________________ Signature of Training Officer:_____________________________________________________________ Date Completed:_____________________________ Central Valley Fire District 205 East Main St Belgrade, MT, 59714 (406) 388-4480 Task Qualification Record Books (Task Book) have been developed for skills verification within the Central Valley Fire District. Each Task Book lists the Skills Verification Tasks for the specific certification level in a format that allows a candidate to be trained and evaluated during two (2) sequential sessions. Successful performance of all Firefighter 1 tasks, as observed and recorded by a qualified and approved evaluator will be required for the candidate’s eligibility to be removed from probationary status. The Skills Verifications covered in this Task Book are not necessarily skills that are required to be tested for certification as Firefighter 1; some of these are skills needed to operate as a structural Firefighter with the Central Valley Fire District. Those that are testable for Firefighter 1 meet or exceed all NFPA published standards for this certification level at the time of this publication.

Transcript of NFPA Firefighter 1 Skills Verification Task Book

Central Valley Fire District/Belgrade City Fire Department

NFPA Firefighter 1 Skills Verification Task Book

July 2014

Based on IAFC Fundamentals of Fire Fighter Skills, Third Edition, Meeting the requirements of NFPA 1001, 2008

edition

Task Book Assigned to:

Name: ____________________________________________________________ ___________________

Skill Book Initiated: __________________________

Signature of Training Officer:_____________________________________________________________

Date Completed:_____________________________

Central Valley Fire District

205 East Main St

Belgrade, MT, 59714

(406) 388-4480

Task Qualification Record Books (Task Book) have been developed for skills verification within the Central Valley Fire District. Each Task Book lists the Skills Verification Tasks for the specific certification level in a format that allows a candidate to be trained and evaluated during two (2) sequential sessions. Successful performance of all Firefighter 1 tasks, as observed and recorded by a qualified and approved evaluator will be required for the candidate’s eligibility to be removed from probationary status. The Skills Verifications covered in this Task Book are not necessarily skills that are required to be tested for certification as Firefighter 1; some of these are skills needed to operate as a structural Firefighter with the Central Valley Fire District. Those that are testable for Firefighter 1 meet or exceed all NFPA published standards for this certification level at the time of this publication.

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

2

Table of Contents

Donning Personal Protective Clothing FF1-1A Page 3

Tying Knots FF1-1B Page 4

Hoist Tool/Equipment FF1-1C Page 5

Transmit and Receive radio Message FF1-2C Page 6

Don SCBA FF-3A Page 7

Use SCBA During Emergency Operations FF1-3B Page 8/9

Respond on an Apparatus to an Emergency Scene FF1-3C Page 10

Operate in Established Work Area at Emergency Scene FF1-3D Page 11

Forcible Entry FF1-3E Page 12/13

Exit Hazardous Environment FF1-3F Page 14

Ground Ladders FF1-3G Page 15/16

Attack a Passenger Vehicle Fire FF1-3H Page17

Deploy and Operate a Master Stream Device FF1-3H-1A Page 18

Conduct a Search and Rescue in a Structure FF1-3J Page 19

Search and Rescue From a Second Floor Window Over a Ladder FF1-3J-1A Page 20/21

Attack an Interior Structure Fire FF1-3K Page 22

Attack an Interior Structure Fire Using a Transitional Attack FF1-3K-1A Page 23

Attack a Structure Fire Using a Defensive Attack FF1-3K-2A Page 24

Perform Horizontal Ventilation on a Structure FF1-3L Page 25

Perform Vertical Ventilation on a Structure, Flat Roof FF1-3M Page 26

Perform Vertical Ventilation on a Structure, Pitched Roof FF1-3N Page 27

Overhaul a Fire Scene FF1-3O Page 28

Conserve Property at a Fire Scene, Salvage FF1-3P Page 29

Connect a Fire Department Pumper to a Water Supply FF1-3Q Page 30/31

Extinguish Incipient Class A, B and C Fires with Portable Extinguishers FF1-3R Page 32

Illuminate the Emergency Scene FF1-3S Page 33

Turn Off Building Utilities FF1-3T Page 34

Cleaning and Checking Equipment FF1-5A Page 35/26/37

Clean, Inspect and Return Fire Hose to Service FF1-5B Page 38/39

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

3

5.1 General Requirements FFI -1A Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.1.2, NFPA 1001, 2008 Edition

Donning Personal Protective Clothing

Task: Donning personal protective clothing within one (1) minute. Doff personal protective clothing and prepare for reuse.

Performance Outcome: The candidate shall be able to properly don personal protective clothing and to prepare the personal protective

clothing for reuse.

No.

Task Steps

First Test

Retest

P

F

P

F

DONNING

1. Don hood

2. Don pants and boots properly-including suspenders in place.

3. Don coat-including storm flap closed and collar up and secured.

4. Don helmet.

5. Don gloves.

6. Complete above correctly within one minute.

DOFFING

7. Place all equipment in a ready state for reuse.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

4

5.1 General Requirements FFI -1B Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.1.2, NFPA 1001, 2008 Edition

Tying Knots

TASK: Tie the six following knots: Bowline knot, Clove hitch, Figure eight on a bight, Half hitch, Becket/sheet bend, and Safety

knots(s).

Performance Outcome: Given appropriate and adequate rope(s) and in full personal protective clothing, the candidate shall demonstrate the

ability to tie the six knots listed below.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Bowline knot

2. Clove hitch

3. Figure eight on a bight

4. Half hitch

5. Becket or sheet bend

6. Water Knot

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

5

5.1 General Requirements FFI -1C Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.1.2, NFPA 1001, 2008 Edition

Hoist Tool/Equipment

TASK: Hoist a tool and/or piece of equipment using the correct knot(s).

Performance Outcome: Demonstrate the ability to tie an approved knot and hoist or have hoisted a tool or piece of equipment to a designated

height, as specified by evaluator.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Tie an approved knot(s) for the tools or equipment selected.

2. Utilize a safety knot for additional support.

3. Hoist or have hoisted a tool and/or piece of equipment to a designated height.

4. Maintain control of object being hoisted to prevent it from swinging out of

control while hoisting (tag line required except when hoisting hoseline)

Circle tool and/or piece of equipment selected by evaluator:

Axe (must be hoisted head down) pike pole (must be hoisted head up)

chain saw hoseline (wet or dry) ground ladder

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

6

5.2 Fire Department Communications FFI -2C Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.2.3, NFPA 1001, 2008 Edition

Transmit and Receive Radio Messages

TASK: Transmit and receive messages via the fire department radio.

Performance Outcome: Demonstrate the ability to operate radio equipment and discriminate between routine and emergency traffic.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Determine the radio is on and tuned to assigned/appropriate

frequency/channel

2. Use department’s operating procedures and/or codes

3. Routine Traffic – Determine air is clear before transmitting (unless emergency

traffic)

4. Emergency Traffic – Announce emergency traffic, even if interrupting

other traffic, if necessary

5. Have microphone within 1 – 2 inches of mouth (or speaking device of SCBA)

6. Speak calmly, clearly, distinctly, and at a medium speed

7. Transmit a message using clear text that is brief, accurate, and to the point

8. Identify the person or unit being called

9. Identify the person or unit transmitting

10. Provides correct information during mayday situation (as determined by AHJ).

11. Acknowledge and respond appropriately to received messages

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

7

5.3 Fire Ground Operations FFI -3A Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.1, NFPA 1001, 2008 Edition

Don SCBA

TASK: Use SCBA during emergency operations: correctly don and activate the SCBA in one minute.

Performance Outcome: While operating at a simulated fire scene or cab of apparatus, and in full protective clothing, shall be able to correctly

don and activate the SCBA in one minute.

No.

Task Steps

First Test

Retest

P

F

P

F

1.

Correctly don SCBA including:

• Check amount of air in cylinder; and

• Check operation of low air alarm

2.

Correctly don face piece including:

• Check seal; and

• Operation of exhalation valve

3. Activate and check PASS device

4. Have all personal protective clothing correctly in place

5. Accomplished all of the above correctly in one minute or less

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

8

5.3 Fire Ground Operations FFI -3B Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.1, NFPA 1001, 2008 Edition

Use SCBA During Emergency Operations

TASK: Use of SCBA during emergency operation: perform conservation of air and emergency procedures.

Performance Outcome: While operating in a simulated hazardous environment, shall be able to use controlled breathing techniques and

perform emergency procedures in the event of SCBA failure.

No.

Task Steps First Test

Retest

P

F

P

F

I. CONSERVATION OF AIR

1.

Demonstrate controlled breathing when instructed to

(e.g., inhale through the nose, exhale through the mouth, and control rate of breathing)

II.

SCBA REGULATOR FAILURE

1.

Emergency procedures when air is not flowing into the face piece:

Check that cylinder is fully open

Close mainline, if present

Open bypass slowly

Close bypass after each breath

Open bypass for next breath

Exit hazardous area rapidly

III.

DEPLETION OF AIR SUPPLY

1.

Emergency procedures when out of air with no air re-supply available

Activate pass device

Exit hazardous area rapidly

2.

Emergency procedures when out of air with a full cylinder available in a non IDLH

Doff backpack

Close cylinder valve and release pressure

Disconnect hose from cylinder

Remove depleted cylinder

Replace with cylinder containing air

Connect hose to cylinder

Turn on cylinder

Redon back pack

IV.

PASS DEVICE USE

1. Activate PASS device in alarm mode “panic button”

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

9

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

10

5.3 Fire Ground Operations FFI -3C Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.2, NFPA 1001, 2008 Edition

Respond on an Apparatus to an Emergency Scene

TASK: Respond on an apparatus to an emergency scene.

Performance Outcome: Shall be able to respond safely in a fire department apparatus and to safely dismount at the emergency scene while

demonstrating the ability to use each piece of provided safety equipment.

No.

Task Steps

First Test

Retest

P

F

P

F

MO

U

N

T

I

N

G

MOUNTING

1. Determine that vehicle is not in motion

2. Mount fire apparatus using handrails and steps

3. Close door of cab

4. Sit, fasten seat belt, and notify driver

5. Correctly use hearing protection

DISMOUNTING

1. Wait for orders before leaving apparatus

2. Ensure that vehicle is completely stopped before disconnecting restraints and

preparing to leave apparatus

3. Look for hazards before stepping off vehicle.

4. Exit apparatus when safe to do so and safely step from vehicle using handrails

and steps

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

11

5.3 Fire Ground Operations FFI -3D Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.3, NFPA 1001, 2008 Edition

Operate in Established Work Areas at Emergency Scene

TASK: Operate in an established work area at an emergency scene.

Performance Outcome: Shall be able to use personal protective equipment, deploy traffic and scene control devices, dismount apparatus, and

operate in the protected work areas as directed.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Survey emergency scene for hazards according to department SOPs.

2. Identify potential for injury based on identified hazards.

3. Verbalize a plan for mitigation of hazards.

4. Properly dismounts apparatus with PPE correctly worn.

5. Using traffic cones, and verbalizing the placement of apparatus, establish a safe work area.

6. Verbalize how structure, roadway emergency scenes, traffic hazards, and downed power lines would be treated and isolated.

7. Verbalize dynamic nature of scene safety.

8. Describe measures to ensure continued scene safety.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

12

5.3 Fire Ground Operations FFI -3E Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.4, NFPA 1001, 2008 Edition

Forcible Entry

TASK: Force entry into a structure, given personal protective equipment, tools, and an assignment, so that the tools are used as designed,

the barrier is removed, and the opening is in a safe condition and ready for entry.

Performance Outcome: shall be able to properly force entry into a structure through doors, windows, and walls using assorted methods and

tools.

No.

Task Steps

First Test

Retest

P

F

P

F

DOOR

1. Select the correct tool(s).

2. Safely carry the selected tool(s) to the door.

3. Try the door to make sure locked before forcing.

4. Correctly size up the door.

5. Choose the appropriate technique and demonstrate forced entry.

6. Use hand and eye protection.

7. Clear opening of obstacles.

WALL

1. Select the correct tool(s).

2. Safely carry the selected tool(s) to the wall.

3. Sound for studs if appropriate.

4. Choose the appropriate technique and demonstrate forced entry.

5. Use hand and eye protection.

6. Clear opening of obstacles.

WINDOW

1. Select the correct tool(s).

2. Safely carry the selected tool(s) to the window.

3. Try the window to make sure locked before forcing.

4. Correctly size up the window.

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

13

5. Choose the appropriate technique and demonstrate or simulate forced entry.

6. Use hand and eye protection.

7. Clear opening of obstacles.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

14

5.3 Fire Ground Operations FFI -3F Revised 7/2014

Firefighter: Date:

Fire Fighter I, 5.3.5, NFPA 1001, 2008 Edition

Exit Hazardous Environment

TASK: Use SCBA during emergency operation: Exit a hazardous, vision-obscured area to a safe haven, maintaining team integrity,

before the air supply is exhausted.

Performance Outcome: Shall be able to identify the need to exit a hazardous area, develop a plan of egress, communicate the plan to

supervisor and subordinate, and exit the hazardous area.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Determine air supply available when entering hazardous atmosphere

2. Monitor the air supply available while in hazardous atmosphere

3. Identify the need to exit the hazardous environment (e.g. low air alarm, SCBA failure)

4. Remain calm and consider actions

5. Communicate and coordinate egress with team member

6. Communicate situation by radio utilizing emergency traffic

7. Activate PASS device

8. Maintain team integrity

9. Attempt to retrace route to outside

10. a. If hoseline is found, determine direction to exit and follow line out

b. If wall is located, remain in contact and follow making consistent turns,

checking for doors and windows to exit

11. When exit is located, retreat from building before air supply is exhausted

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

15

5.3 Fire Ground Operations FFI -3G Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.6, NFPA 1001, 2008 Edition

Ground Ladders

TASK: Set up ground ladder.

Performance Outcome: Demonstrate the ability to carry ladders, raise ladders, extend ladders and lock flies, determine that a wall and roof

will support the ladder, judge extension ladder height requirements, and place the ladder to avoid obvious hazards.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Select the proper length ladder for the designated task.

2. Lift/carry the ladder from the designated area or apparatus.

3. Visually check work area for hazards and state if area is safe or if hazards exist.

4. Raise the ladder upright in a safe manner.

5. Extend and secure fly section (if using an extension ladder).

6. Lower ladder against stable wall or surface.

7. Adjust for proper climbing angle.

8. Secure the halyard with either a clove-hitch or round turn and two half hitches

9. Position ladder correctly for task given.

CIRCLE ONE TASK:

Window Ventilation: Place alongside to windward (upwind) side, with tip even or

above top of window.

Rescue from window or entry through window: Placed slightly below sill or 2-3

rungs into window if opening is wide enough to allow room beside ladder to rescue or

entry.

Access roof: Placed against roof with 3-5 rungs above roof.

9. Lower ladder to ground (reversing raising procedures).

10. Lift/carry ladder to designated site or apparatus.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

16

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

17

5.3 Fire Ground Operations FFI -3H Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.7, NFPA 1001, 2008 Edition

Attack a Passenger Vehicle Fire

TASK: Attack a passenger vehicle fire operating as a member of a team.

Performance Outcome: While operating as a member of a team at a vehicle fire, shall properly attack and extinguish the fire.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Properly wear full protective clothing and SCBA (on air).

2. Attack from upwind and uphill (verbalize conditions were considered if not applicable).

3. Protect exposures (if present).

4. Identify possible fuel types and methods for controlling fuel leaks.

5. Select at least 1 ½ inch hose line, bleed line, and adjust nozzle.

6. Approach vehicle from 45 degree angle (never placing crew in front of bumpers until cooled) using nozzle setting for team protection.

7. Extinguish ground fire around and under the vehicle and then attacks the remaining fire in the vehicle (gaining any access needed) and extinguishes the fire.

8. Overhaul the fire scene.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

18

5.3 Fire Ground Operations FFI -3H-1A Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.8, NFPA 1001, 2008 Edition

Deploy and Operate a Master Stream Device

TASK: While operating as an individual or as a member of a team, deploy and operate a master stream device.

Performance Outcome: While operating at a simulated structure fire, demonstrate the ability to deploy and operate both a Deck Gun and

Blitz Fire Monitor for either Defensive Fire Attack or Exposure Protection.

No.

Task Steps

First Test

Retest

P

F

P

F

DECK GUN/FRONT BUMPER TURET

1.

Makes sure all firefighting personnel are out of structure before using deck gun.

2.

Places deck gun into correct position.

3.

Aims deck gun at fire or target exposure.

4.

Signals for water.

5. Once water is flowing aim at fire or exposure, adjusts angle or water flow as necessary.

BLITZ FIRE

1.

Makes sure all firefighting personnel are out of structure before using Blitz Fire.

2.

Removes Blitz Fire from apparatus and pulls 100’ bundle onto shoulder.

3.

Move monitor and hose forward allowing bundle to deploy off shoulder until into

desired position.

4.

Drop remaining bundle and extend legs of the monitor, get 8’-10’ of hose in-line with

Blitz Fire. Flake out any extra hose.

5.

Signals for water.

6.

Once water is flowing aim at fire or exposure, adjusts angle or water flow as necessary.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

19

5.3 Fire Ground Operations FFI -3J Revised 7/2014

Firefighter: Date:

Fire Fighter I, 5.3.9, NFPA 1001, 2008 Edition

Conduct a Search and Rescue in a Structure

TASK: Conduct and complete a primary search of an obscured visibility area, locating and removing all victim(s), while operating as a

member of a team and using an attack line.

Performance Outcome: Demonstrate the necessary skills to conduct a primary search, covering as wide of an area as quickly as possible,

removing the victim(s) to designated safe havens, and maintaining team integrity and communication.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Properly wear full protective clothing and SCBA on air

2. Size up the problem and select the appropriate tool(s) and equipment

3. Correctly open all doors (feeling for heat and opening slowly, keeping

control of the door ) or windows

4. Establish and maintain an effective search pattern

5. Search in a body position appropriate for conditions (e.g., crawling, walking)

6. Maintain team communication, safety, and integrity

7. Use hoseline or guideline effectively

8.

Find and correctly remove all victims

CIRCLE Victim(s) Rescued: Person without FireFighter with Firefighter with

Respiratory Protection NON-FUNCTIONING FUNCTIONING

SCBA SCBA

9. Complete the primary search

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

20

5.3 Fire Ground Operations FFI -3J-1A Revised 7/2014

Firefighter: Date:

Fire Fighter I, 5.3.9, NFPA 1001, 2008 Edition

Search and Rescue From a Second Floor Window Over a Ladder

TASK: Conduct and complete a primary search of a second floor, locating and removing all victim(s) over a ladder, while operating as a

member of a team.

Performance Outcome: Demonstrate the necessary skills to raise a ladder for a window rescue, safety conduct a primary search, locate a

victim and place on the ladder, and bring the victim safely down the ladder to designated safe haven while maintaining team integrity and

communication.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Properly wear full protective clothing and SCBA on air while in the IDLH environment

2. Size up the problem and select the appropriate tool(s) and equipment

3. Raise a ladder to the window

4. Ensure the ladder is heeled, secured, and at the proper climbing angle

5. Ascend the ladder

6. Properly clear window of obstruction as needed

7. Reposition ladder and advance hoseline through the window

5. Establish and maintain an effective search pattern

7. Maintain team communication, safety, and integrity

7. Use hoseline effectively

7. Find and correctly remove all victims

Conscious Victim

Victim is lowered feet first from the building to the ladder

Rescuer on the ladder supports victim and descends ladder, keeping both arms around

victim under the armpits with hands on rungs in front of the victim (rescuer constantly

reassures the victim)

Unconscious Victim

Same as conscious victim, except victim’s body rests on the rescuer’s knee with the

victim’s feet outside the rails;

Victim faces away from the rescuer, victim’s armpits are supported by rescuer’s arms

while descending with rescuer’s hand sliding down the beam

6. Rescuer safely descends the ladder with victim

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

21

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

22

5.3 Fire Ground Operations FFI -3K Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.10, NFPA 1001, 2008 Edition

Attack an Interior Structure Fire

TASK: Attack an interior structure fire operating as a member of a team.

Performance Outcome: While operating as the nozzle person of a team at an interior structure fire involving Class A materials shall properly

attack and extinguish the fire.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Properly wear full protective clothing and SCBA on air

2. Select proper preconnected hose line

3. Deploy hose from hosebed or crosslay to designated target area

4. Remove or have kinks removed in hose

5. Secure nozzle, call or signal for water, bleed air from the attack line, and adjust nozzle

for desired stream

6. Cover door to protect team member as door is checked

7. Stay low on entering and approaching fire

8.

Extinguish the fire using the attack pattern directed to use by evaluator

Circle attack pattern(s) directed to use:

DIRECT INDIRECT COMBINATION

9. Locate and suppress hidden void space fires

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

23

5.3 Fire Ground Operations FFI -3K-1A Revised 7/2014

Firefighter: Date:

Fire Fighter I, 5.3.10, NFPA 1001, 2008 Edition

Attack an Interior Structure Fire Using a Transitional Attack

TASK: Attack an interior structure fire using a transitional attack starting from an exterior position while operating alone or as a

member of a team.

Performance Outcome: While operating as the nozzle person of a team at a simulated structure fire a knock attack an interior structure fire

using a transitional fire attack.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Properly wear full protective clothing and SCBA on air while in the Hot Zone

2. Select proper preconnected hose line

3. Deploy hose from hosebed or crosslay to designated target area

4. At the direction of the Company Officer direct water stream on to interior structure fire

from an exterior position

5. Use solid stream to control (knock down/blacken) fire

6. Notify Company Officer of the condition of the fire

7. Hold in place to watch for flare ups or … (At discretion of the Company Officer)

8. Rejoin crew and prepare to make entry into the structure

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

24

5.3 Fire Ground Operations FFI -3K-2A Revised 7/2014

Firefighter: Date:

Fire Fighter I, 5.3.10, NFPA 1001, 2008 Edition

Attack a Structure Fire Using a Defensive Fire Attack TASK: Attack a structure fire using a defensive fire attack with a 2 ½” from an exterior position. Performance Outcome: While operating as the nozzle person of a team at a simulated structure fire attack a structure fire using a 2 1/2”

hoseline.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Properly wear full protective clothing and SCBA

2. Select proper preconnected hose line

3. Deploy hose from hosebed to designated target area

4. Must be “On Air” in the Hot Zone

5. Ensure all interior operations have stopped before flowing water

6. “Deploy” hose using proper technique, aim at fire, and readjust position or water flow as

necessary.

7. Continue to fight fire until fire under control or relived by another crew

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

25

5.3 Fire Ground Operations FFI -3L Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.11, NFPA 1001, 2008 Edition

Perform Horizontal Ventilation on a Structure

TASK: While operating as part of a team, perform horizontal ventilation on a structure.

Performance Outcome: Demonstrate the ability to perform horizontal ventilation by creating intake and exhaust openings as needed and

utilizing ventilation tools, equipment and ladders, and to use safe procedures for breaking window and door glass and removing obstructions.

No.

Task Steps

First Test

Retest

P

F

P

F

BREAK WINDOW OR DOOR GLASS

1. Properly place ladder (if necessary).

2. Choose proper tool for task and carry tool safely.

3. Assume proper position and break glass

4. Remove glass and any remaining window obstruction.

FORCED VENTILATION (Choose Positive or Hydraulic)

Positive Pressure Ventilation

1. Confirm no crews are between the fire and exhaust opening.

2. Properly place fan in front of entry point.

3. Have exit point no larger than necessary to allow for adequate ventilation.

Hydraulic Ventilation

1. Have fog pattern at least 2 feet back and covering 85-90% of opening.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

26

5.3 Fire Ground Operations FFI -3M Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.12, NFPA 1001, 2008 Edition

Perform Vertical Ventilation on a Structure, Flat Roof

TASK: While operating as part of a team, perform vertical ventilation on a flat roof.

Performance Outcome: While operating as a member of a team at a simulated structure fire, shall be able to properly perform vertical

ventilation on a structure with a flat roof.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Collect and organize necessary equipment and tools

2. Ensure power saw operates

3. Direct team member to heel the ladder

4. Ascend the ladder carrying selected ventilation tools

5. Move tools to roof utilizing teamwork

6. Check roof integrity by sounding roof prior to stepping off ladder

7. Keep sounding roof as moves on roof

8. Work with wind to back, if possible

9. Locate roof supports, at highest point near the fire, by sounding

10. Make an opening at least 4’ x 4’ in size

11. Remove appropriate roof material after cuts

12. Push ceiling through

13. Have team exit roof immediately after completing ventilation, making sure

the ladder is heeled

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

27

5.3 Fire Ground Operations FFI -3N Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.12, NFPA 1001, 2008 Edition

Perform Vertical Ventilation on a Structure, Pitched Roof

TASK: While operating as part of a team, perform vertical ventilation on a pitched roof.

Performance Outcome: While operating as a member of a team at a simulated structure fire, shall be able to properly perform vertical

ventilation on a structure with a pitched roof.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Collect and organize necessary equipment and tools

2. Ensure power saw operates

3. Direct team member to heel the ladder

4. Ascend the ladder carrying selected ventilation tools

5. Move tools to roof utilizing teamwork

6. Check roof integrity by sounding roof prior to stepping off ladder

7. Work off roof ladder, when possible, to ensure distribution of weight

8. Work with wind to back, if possible

9. Locate roof supports, at highest point near the fire, by sounding

10. Make an opening at least 4’ x 4’ in size

11. Remove appropriate roof material after cuts

12. Push ceiling through

13. Have team exit roof immediately after completing ventilation, making sure

the ladder is heeled

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

28

5.3 Fire Ground Operations FFI -3O Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.13, NFPA 1001, 2008 Edition

Overhaul a Fire Scene

TASK: Overhaul a fire scene.

Performance Outcome: While operating at the scene of a simulated or live structure fire, shall properly perform overhaul so that hidden fires

are discovered and extinguished with any evidence present preserved.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Properly wear full protective equipment and SCBA on air

2. Select proper equipment and extinguishing source for the overhaul according to scenario

3. Demonstrate locating hidden fires by sight, touch, sound, or electronic sensor

4. Protect area with salvage cover or visqueen

5. Expose hidden fires in ceiling, walls, and/or floors

6. Remove or extinguish burning objects

7. Evaluate for complete extinguishment

8. Preserve evidence or signs of origin and cause

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

29

5.3 Fire Ground Operations FFI -3P Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.14, NFPA 1001, 2008 Edition

Conserve Property at a Fire Scene, Salvage

TASK: Conserve property as a member of a team.

Performance Outcome: While operating as a member of a team at a simulated live fire scene, shall properly perform salvage operations.

No.

Task Steps

First Test

Retest

P

F

P

F

1. Arrange furnishing in a close pile(s) and raised off the floor, if possible

2. Cover the pile with a salvage cover using one of the options listed below

(circle option used):

One firefighter throw One firefighter spread

Two firefighter balloon throw Two firefighter spread

Other:

3.

Construct or perform one of the below called for (circle one used):

a. Water Catch-All b. Water Chute

c. Stop Activated Sprinkler d. Operate a main control valve

4. Refold salvage cover

5. Separate, remove, and relocate charred material to a safe location while protecting

the area of origin for cause determination

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

30

5.3 Fire Ground Operations FFI -3Q Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.15, NFPA 1001, 2008 Edition

Connect a Fire Department Pumper to a Water Supply

TASK: Connect a fire department pumper to a water supply.

Performance Outcome: While operating at a simulated structure fire, shall be able to properly connect a supply hose to a hydrant or a static

water source and furnish water to a pumper.

No.

Task Steps

First Test

Retest

CIRCLE: Fire Hydrant or Static Water Source

P

F

P

F

FIRE HYDRANT CONNECTION VIA FORWARD & REVERSE LAY

1. Connect supply hose to hydrant.

2. Connect supply hose to pumper intake.

3. Fully open hydrant.

4. Remove kinks from hose.

5. At end of operation, fully close the hydrant.

6. Place all equipment and hydrant in a ready condition.

STATIC WATER SOURCE

1. Deploy portable water tank.

2. Check gaskets on the hard suction hose for dirt, gravel or defects.

3. Connect foot value to suction hose.

4. Couple two (2) section of hard suction hose if needed.

5. Connect hard suction hose to pumper.

6 Use rubber mallet and/or spanner (as appropriate) to ensure air tight connections.

7. Lower hose and strainer into static water source.

8. Signal pumper operator to start drafting procedure.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

31

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

32

5.3 Fire Ground Operations FFI -3R Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.16, NFPA 1001, 2008 Edition

EXTINGUISH INCIPIENT CLASS A, B, AND C FIRES WITH

PORTABLE FIRE EXTINGUISHERS

TASK: Extinguish incipient Class A, Class B, and Class C fires with appropriate fire extinguisher.

Performance Outcome: Demonstrate the ability to operate portable fire extinguishers, approach fire with portable fire extinguishers, select an

appropriate extinguisher based on the size and type of fire, and safely carry portable fire extinguishers

No.

Task Steps

First Test

Retest

CIRCLE CLASS OF FIRE TO BE EXTINGUISHED:

Class A Class B Class C

P

F

P

F

1. Correctly identify the class of fire.

2. Select an extinguisher suitable for fire given.

3. Properly activate the extinguisher (pull pin and/or puncture cartridge).

4. Test operations of the extinguisher by a brief discharge of agent.

5. Approach to an effective distance for discharge of the selected extinguisher (Water -

30-40 ft. maximum; Dry Chemical - 20 ft.).

6. Discharge extinguisher agent on the base of the fire and sweep over the fire area.

7. Advance on the remaining burning material while continuing to extinguish hot spots.

8. Extinguish the fire and check for remaining hot spots.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

33

5.3 Fire Ground Operations FFI -3S Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.17, NFPA 1001, 2008 Edition

ILLUMINATE THE EMERGENCY SCENE

TASK: Illuminate the emergency scene.

Performance Outcome: While operating on a simulated fire ground, shall be able to properly and safely illuminate the scene and ensure the

equipment is operated within manufacturer's safety precautions.

No.

Task Steps

First Test

Retest

1. Lift equipment safely.

P

F

P

F

2. Locate power plant in a remote and well vented location.

3. Arrange power cords neatly to minimize trip hazards.

4. Organize lights in a useful position to illuminate the area sufficiently.

5. Start power plant.

6. Plug cords into unit or junction box and furnish illumination.

7. Shut down equipment when told to do so.

8. Allow equipment to cool down before returning to service or verbally explain the need to do so.

9. Clean equipment, check oil, and refuel power plant or verbally explain the need to do so.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

34

5.3 Fire Ground Operations FFI -3T Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.3.18, NFPA 1001, 2008 Edition

TURN OFF BUILDING UTILITIES

TASK: Turn off building utilities.

Performance Outcome: While operating on a simulated fire ground, shall be able to locate and properly turn off the utilities to a structure

and assess area for related hazards.

No.

Task Steps

First Test

Retest

P

F

P

F

LOCATE UTILITY SERVICE BOXES

1. Electrical-main panel.

2. Natural gas-meter or LPG/CNG-storage tank/cylinder.

SHUT OFF UTILITY

4. Electrical-breaker to “off.”

5. Natural gas-gas cock to “off” or LPG/CNG-turn valve clockwise to close.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

35

5.5 Prevention, Preparedness, and Maintenance FFI -5A Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.5.1, NFPA 1001, 2008 Edition

CLEANING AND CHECKING EQUIPMENT

TASK: Clean and visually check Fire Department tools and equipment.

Performance Outcome: Demonstrate the ability to properly clean and visually check tools and various parts and pieces of equipment, follow

guidelines, and complete recording and reporting procedures.

No.

Task Steps

First Test

Retest

P

F

P

F

EQUIPMENT TO BE CLEANED AND INSPECTED (SCBA Mandatory &

Circle One Other): Ladder Hand Tools Ventilation Equipment

SCBA Ropes Salvage Equipment

LADDERS

1. Remove dirt with brush and running water.

2. Use approved solvents to remove any oily and greasy residue.

3. Wipe dry.

4. Examine all beams, guides, halyard, cable, pawls, pulleys, rails, rungs, bolts, rivets, welds, heat indicator, and movable parts.

5. Check lubrication of moveable parts and lubricate if necessary.

6. Mark defects when found in accordance with manufacturer or department guidelines.

7. If no defects found, place equipment in ready state.

HAND TOOLS

1.

Wooden Handles:

Check for cracks, blister, or splinters. Sand wooden handles if needed.

Clean with soap water, rinse, and dry after use.

Check to ensure head is on tight.

2.

Fiberglass Handles:

Wash with warm, soapy water. Dry with soft, dry cloth.

Check to ensure head is on tight.

3.

Cutting Edges:

Check to ensure cutting edge is free of nicks or tears. Sharpen edge with hand file

4.

Plated Surfaces: Inspect for damage. Wipe plated surface clean or wash with soap and water.

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

36

5.

Unprotected Metal Surfaces:

Keep clean of rust. Keep oiled when not in use (light machine oil will work).

Check to ensure not painted as this may hide cracks.

File off if found.

VENTILATION EQUIPMENT

1. Check starting.

2. Check blades for completeness and readiness.

3. Check electric cords for cut and frays.

4. Check that appropriate guards are in place.

SCBA

1. Wash face piece, low pressure hose, and exhalation valve with Department’s cleaner/disinfectant and rinse completely with clear water and air dry.

2. Clean SCBA with damp cloth or according to department policies.

3. Check straps and backpack assembly.

4. Check condition and hydrostatic test date of cylinder.

5. Turn the cylinder valve on fully.

6. Compare that two pressure gauges are within 100 psi of each other.

7. Check face piece, hose, and exhalation valve by inhaling and exhaling.

8. Check regulator operation by connecting to face piece and breathing.

9. Check by-pass operation and ensure by-pass is in the off position after testing.

10. Check low pressure alarm while bleeding the air line.

11. Return all straps, valves and components back to ready state.

12. Check the air cylinder is in the off position and for adequate air pressure (90%-full).

13. Candidate will notify supervisor of any irregularities found.

ROPES

1. Check the entire surface of the rope for cuts, abrasions, stains, odor, or fraying.

2. Examine the inner component by twisting the rope or feeling for bunching and thinness.

3. Verbally explains that he/she would tag and remove from service the damaged rope.

4. Clean rope using clear water.

5. Allow rope to dry completely, or state rope must be allowed to dry completely.

6. Perform additional inspection after drying.

7. Properly store rope using coil method or rope bag storage.

SALVAGE EQUIPMENT

1. Clean provided salvage equipment.

2. Inspect equipment and identify damage.

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

37

3. Spread the salvage cover out flat for cleaning.

4. Scrub the cover with detergent solution and a brush.

5. Rinse cover thoroughly.

6. State cover should be thoroughly dried before returning to service.

7. Check the cover thoroughly for damage by having assistants hold the cover above heads while looking for holes and tears.

8. Use department procedure for indicating repair needed.

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

38

5.5 Prevention, Preparedness, and Maintenance FFI -5B Revised 6/2014

Firefighter: Date:

Fire Fighter I, 5.5.2, NFPA 1001, 2008 Edition

CLEAN, INSPECT, AND RETURN FIRE HOSE TO SERVICE

TASK: Clean, inspect, and return fire hose to service.

Performance Outcome: Shall be able to properly clean, inspect and properly return fire hose to service.

No.

Task Steps

First Test

Retest

P

F

P

F

CLEAN HOSE

1. Clean hose using water and scrub brush (mild detergent may be used).

2. Clean couplings by removing gaskets, wash with warm, soapy water and reinstalling gaskets (replacing if defective).

3. Dry hose.

INSPECT HOSE

4. Check for signs of mechanical damage.

5. Check for dirt and debris.

6. Check for loose couplings.

7. Check for damaged male or female threads.

8. Check swivel operates freely and hose couples and uncouples properly.

9. Place damaged hose out of service until repaired.

RETURNING HOSE TO SERVICE

10.

Roll hose as selected by proctor (Circle one):

Straight Donut

11.

Reload hose on apparatus as selected by proctor (Circle one):

ACCORDIAN with and without Dutchman COMBINATION

FLAT with and without Dutchman TRIPLE FOLD MINUTEMAN

Central Valley Fire District/Belgrade City Fire Department Firefighter 1 Taskbook

39

Proctor/Evaluator Comments: ________________________________________________________

__________________________________________________________________________________

___________________________________________________________________________________

Proctor/Evaluator (Print & Sign) Date Firefighter Date

Re-Test Proctor/Evaluator (Print &

Sign)

Date Re-Test Firefighter Date