NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE,...

9
-1- NEW VERDERA INSTALLATION INSTRUCTIONS MIRRORED CABINET K-78202T-L/K-78202T-R/K-78282T BEFORE YOU BEGIN BEFORE YOU BEGIN · · · · · Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation . This will help you avoid costly mistakes. In addition to proper installation, read all operating and safety instructions. All information in these instructions is based upon the latest product information available at the time of publication. Kohler China. reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and warranty information- Before installation carefully inspect the new fixture for any signs of damage. This product complies with GB/T10357.4-2013, GB/T10357.5-2013 and GB24977-2010. Be careful when opening the door to avoid pinching fingers. Don't use acidic or alkalic cleaners or alcohol to clean the surface. Use a dampened cloth to clean. Electrical wiring may need to be relocated. Use anchors (not provided) rated for the loaded weight of this product. Refer to the anchor manufacturer's instructions. This cabinet is designed for either right or left door swing. Check the wall cavity for obstructions. please leave instructions for the consumer. WARNING: Risk of injury or product damage. WARNING: CAUTION: Risk of electric shock. CAUTION: Risk of property damage. Important Information: · · · · · - GB/T10357.4-2013 GB/T10357.5-2013 GB24977-2010 ZHONGSHAN KOHLER SHOWER CO., LTD. NO13-1, XINGYE ROAD, ZHONGSHAN TORCH DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions WARNING: Risk of electric shock. · · · · This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. Improper use of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord is necessary, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded. This product is factory equipped with a specific electric cord. If the product must be reconnected for use on a different type of electric circuit, the connection should be made by qualified service personnel. · · · · © © Copyright Kohler China Investment Co., Ltd. 2017 2017 1307566-T01-B

Transcript of NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE,...

Page 1: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

-1-

NEW VERDERAINSTALLATION INSTRUCTIONS

MIRRORED CABINET

K-78202T-L/K-78202T-R/K-78282T

BEFORE YOU BEGINBEFORE YOU BEGIN

Please read these instructions carefully to familiarizeyourself with the required tools, materials, and installationsequences. Follow the sections that pertain to yourparticular installation . This will help you avoid costlymistakes. In addition to proper installation, read alloperating and safety instructions.All information in these instructions is based upon the latestproduct information available at the time of publication.Kohler China. reserves the right to make changes inproduct characteristics, packaging, or availability at anytime without notice.These instructions contain important care, cleaning, andwarranty information-

Before installation carefully inspect the new fixture for anysigns of damage.This product complies with GB/T10357.4-2013,GB/T10357.5-2013 and GB24977-2010.

Becareful when opening the door to avoid pinching fingers.

Don't use acidic or alkalic cleaners oralcohol to clean the surface. Use a dampened cloth toclean.

Electrical wiringmay need to be relocated.

Use anchors(not provided) rated for the loaded weight of thisproduct. Refer to the anchor manufacturer's instructions.

This cabinet is designed foreither right or left door swing. Check the wall cavity forobstructions.

please leave instructions for theconsumer.

WARNING: Risk of injury or product damage.

WARNING:

CAUTION: Risk of electric shock.

CAUTION: Risk of property damage.

Important Information:

-

GB/T10357.4-2013 GB/T10357.5-2013

GB24977-2010

ZHONGSHAN KOHLER SHOWER CO., LTD. NO13-1, XINGYE ROAD, ZHONGSHAN TORCH

DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437

13-1 528437

Grounding Instructions

WARNING: Risk of electric shock.

This product should be grounded. In the event of anelectrical short circuit, grounding reduces the risk of electricshock by providing an escape wire for the electric current.

Improper use ofthe grounding plug can result in a risk of electric shock.

If repair or replacement of the cord is necessary, do notconnect the grounding wire to either flat blade terminal. Thewire with insulation having an outer surface that is greenwith or without yellow stripes is the grounding wire.Check with a qualified electrician or service personnel if thegrounding instructions are not completely understood, or ifin doubt as to whether the product is properly grounded.This product is factory equipped with a specific electric cord.If the product must be reconnected for use on a differenttype of electric circuit, the connection should be made byqualified service personnel.

©

©

Copyright Kohler China Investment Co., Ltd. 2017

20171307566-T01-B

Page 2: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

-2-

Kohler reserves the right to change marked dimensions without prior notice.

ROUGHING-IN

UNIT : mmReference Value

PARTS SUPPLIEDPARTS SUPPLIED

10

10

(4) (4)

(4 or 5)

(2) (1) (3)

(12)

K-78202T-L/K-78202T-R K-78282T

TOOLS REQUIREDTOOLS REQUIRED

6 4Anchors (as needed)

( )

610

762

866

610 251

762

ROUGHING-IN

Item Electrical Function Type Description Fixate Place

1 1

2 2

Defogger

LightingInput: DC12V, Pmax=15W,LED 3000K

Input: DC12V, Pmax=15W Input: DC12V, Pmax=15W

Input: DC12V, Pmax=15W,LED 3000K

Inside the Door

Back of Outer-mirror

ELECTRICAL PARTS LISTELECTRICAL PARTS LIST

29

133 29

133

1307566-T01-B

Page 3: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

-3-

INSTALLATION

Surface-Mount Installation

STEP2

STEP1

Verify minimum clearances. Mark the mounting bar position (centered as desired). Mark

stud locations.

76mm

76mm

(1905 mm) To Floor(1905 mm)

STEP3

Mark hole locations on the wall. Drill holes. Insert anchors

where needed.

Or

6

STEP4

Secure the bar with round-head screws.

1307566-T01-B

Page 4: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

-4-

STEP7

Lift the cabinet onto the mounting bar. Ensure the hooks

engage the bar.

STEP6

Slide the hanger hooks onto the top T-slot as shown.

T

51mm

STEP5

Rotate the cabinet for right or left door swing with KOHLER

logo on the bottom of the outside mirror.

KOHLER

STEP8

Slide two clips onto the T-slot. Ensure the cabinet is

centered as desired. Drill pilot holes.

T

3/32"

1307566-T01-B

Page 5: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

Measure and mark the cutout.

718mm

"A"

76mm Min76mm

-5-

STEP12

STEP9

If needed, insert anchors into the wall. Secure the clips with

round-headed long screws.

STEP10

Slide two clips onto the bottom T-slot. Drill pilot holes and

secure with round-headed long screws.

T

51mm

3/32"

STEP11

Cut-Out Dimensions.

Model A=WidthA=

K-78202T-L

K-78202T-R

K-78282T

575mm

575mm

828mm

1307566-T01-B

Page 6: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

STEP15

Secure the cabinet to the framing.

STEP14

With help, lift and hold the cabinet in the cutout.

-6-

STEP13

Cut away the drywall.

1307566-T01-B

Page 7: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

Installation and Adjustment of Accessories

STEP2

If needed, align the door.

STEP3

To adjust mirror height, slide up or down.

IMPORTANT! Rotate mirror in before closing the door.

-7-

STEP1

Install the clips. Insert the shelves between the clips.

1307566-T01-B

Page 8: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

Installation of Side Mirror (Note: Not

necessory for recess-mount installation.)

-8-

STEP2

STEP1

Find the two bracket locations on each side of the cabinet. Align the brackets with the mounting holes.

Left Side Right Side

STEP4

STEP3

Secure the brackets with the screws.round-headed short Cover the screws with the screw caps.

1307566-T01-B

Page 9: NEW VERDERA - KOHLERresources.kohler.com/plumbing/kohlerapac/pdf/78282T-NA.pdf · DEVELOPMENT ZONE, ZHONGSHAN, GUANGDONG, CHINA POST CODE: 528437 13-1 528437 Grounding Instructions

STEP1

Power line connection

-9-

Line outlet of cabinet

STEP1

Line outlet for Cabinet

Line outlet for Cabinet

K-78202T-L K-78202T-R K-78282T

50 50

Wire Input(three-core cable)

220V/50Hz( )

Fixture Outlet Wiring Color

Brown

Yellow&Green

BlueNeutral

Ground

Hot

430