New SVM series SVMPC1 / SVMPC2 Ver.1.0
![Page 2: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/2.jpg)
SVMPC1
VRV Tablet Controller for small size building
![Page 3: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/3.jpg)
What is SVMPC1
• SVMPC1 is good for small size office controller
iTM is a good solution for office building VRV management but
is too expensive for small size office.
3
SVMPC1 is the best for such office. SVMPC1 price level is suitable for such small size office.
SVMPC1 solves it by automatic control. SVMPC1 operate VRV automatically by schedule through
whole year.
• SVMPC1 frees people from the management of air-
conditioning
Air-conditioning is used wastefully because there are no air-
conditioning management.
![Page 4: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/4.jpg)
What is SVMPC1
• SVMPC1 saves energy by reducing wasteful operation
SVMPC1 can limit the setpoint range to prevent too low/high
setpoint.
• SVMPC1 has user-friendly operation screen
Everyone can use SVMPC1 without special training by simple easy
screen on tablet.
• SVMPC1 allows to control air-conditioning from anywhere
Your smartphone will be a remote controller for VRV through WiFi
and the Internet.
• SVMPC1 notifies malfunction to service contractor (not in
the premises)
SVMPC1 sends alert e-mail to registered person who in charge of
maintenance. 4
![Page 5: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/5.jpg)
SVMPC1: System Structure
5
WiFi router
DTA116A51 SVMPC1
DTA116A51
Internet
![Page 6: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/6.jpg)
SVMPC1: Functions
6
Category Function Detail
Access security User login User name, password
Device registration Registered device(Tablet, Smartphone) can access
through the internet
Main screen Status monitoring On/Off, Setpoint, Operation mode, Fan step, Flap, Error,
Error code, Room Temperature
Manual operation On/Off, Setpoint, Operation mode, Fan step, Flap
Automatic control Setpoint range
limitation*
Cool setpoint min/max, Heat setpoint min/max
Off timer* Off timer on/off, Off timer duration(5min – 12h, every
5min)
Setback operation* Setback setpoint range (Cool: 24-35C, Heat: 10-20C)
Schedule* Action registration: Time, On/Off, Setpoint, Operation
mode, Fan step, Flap, Off timer on/off, Setback setpoint
Calendar setting: set by date or day of the week
System setting Language English, Spanish, Portuguese, Thai, Vietnam, Simplified
Chinese, Traditional Chinese
Password setting
User administration* Add/Modify/Delete user
Set User name, Password, Accessible points
Point setting* Set point name, Select icon
*: only admin user can set
![Page 7: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/7.jpg)
SVMPC1: Screen image
7
![Page 8: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/8.jpg)
SVMPC1: Specifications
8
Category Specification Detail
Connectable units Number of indoor units Max 32 (with additional DTA116A51)
Number of DTA116A51 Max 2
Connectable device Number of Tablet/Smartphone Max 20
Device type iPad, iPhone, Android tablet, Android
Phone, Windows Tablet, Windows Phone,
Windows PC, Mac
Web browser Firefox, Chrome, Safari
![Page 9: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/9.jpg)
SVMPC2
Smartphone Remote Controller for building
![Page 10: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/10.jpg)
What is SVMPC2
SVMPC2 is a VRV remote controller
• User’s smartphone will be a remote controller of VRV in a building.
10
Wall mounted remote controller is not
necessary.
• VRV can be controlled through the internet.
Whole building WiFi is not necessary.
• Accessible VRV can be limited by setting.
Tenant people can access only their VRV.
• Up to 1024 indoor units can be managed.
SVMPC2 can apply to big building.
![Page 11: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/11.jpg)
SVMPC2: System Structure
11
SVMPC2
DCM601A51
DCM601A51
Router
Internet
In the building Outside of the building
![Page 12: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/12.jpg)
SVMPC2: Functions
12
Category Function Detail
Access security User login User name, password
Device registration Registered device(Tablet, Smartphone) can access
through the internet
Main screen Status monitoring On/Off, Setpoint, Operation mode, Fan step, Flap, Error,
Error code, Room Temperature
Manual operation On/Off, Setpoint, Operation mode, Fan step, Flap
Automatic control Setpoint range limitation* Cool setpoint min/max, Heat setpoint min/max
Off timer* Off timer on/off, Off timer duration(5min – 12h, every 5min)
System setting Language English, Spanish, Portuguese, Thai, Vietnam, Simplified
Chinese, Traditional Chinese
Password setting
User administration* Add/Modify/Delete user
Set User name, Password, Accessible points
Point setting* Set point name, Select icon
*: only admin user can set
![Page 13: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/13.jpg)
SVMPC2: Screen image
13
Login screen Monitor screen
Operation screen Setpoint range limitation
Language setting Password setting User setting Point setting
![Page 14: New SVM series - daikinlatam.com · SVMPC1: Screen image 7 . SVMPC1: Specifications 8 Category Specification Detail Connectable units Number of indoor units Max 32 (with additional](https://reader033.fdocuments.us/reader033/viewer/2022041915/5e6951ae49f0237a9606ebb2/html5/thumbnails/14.jpg)
SVMPC2: Specifications
14
Category Specification Detail
Connectable units Number of indoor units Max 1024 (with 2 iTMs)
Number of iTMs Max 2
Connectable device Number of Tablet/Smartphone Max 200
Device type iPad, iPhone, Android tablet, Android
Phone, Windows Tablet, Windows Phone,
Windows PC, Mac
Web browser Firefox, Chrome, Safari