new resume

6
BALAKRISHNAN.A Mail id : [email protected] Mobile no : 91- 9943247554 Education Bachelor of Engineering (Electrical & Electronics),Year 2013 Periyar maniammai university . Diploma in (Electrical & Electronics), Year 2010 DOTE Experience Successful completion of Two Years Eight Month experience in working on Various Substation, Mines, Refineries & Power plant projects as a Power system Protection and Commissioning Engineer.Having good experience and knowledge of power systems. Specialized Skills Testing & Commissioning: 1. Relay & Control panels 2. Line Distance Protection 3. Feeder Protection 4. Motor Protection 5. Interlock & Isolator Logic 6. Switchyard, Switchgear commissioning . Relays Handled IN SEL SEL751A- Feeder protection SEL 710,749 – Motor protection SEL 787 – Transformer differential protection

Transcript of new resume

Page 1: new resume

BALAKRISHNAN.A Mail id : [email protected] Mobile no : 91-9943247554

Education

Bachelor of Engineering (Electrical & Electronics),Year 2013 Periyar maniammai university . Diploma in (Electrical & Electronics), Year 2010 DOTE Experience

Successful completion of Two Years Eight Month experience in working on Various

Substation, Mines, Refineries & Power plant projects as a Power system Protection and

Commissioning Engineer.Having good experience and knowledge of power systems.

Specialized Skills

Testing & Commissioning:

1. Relay & Control panels 2. Line Distance Protection 3. Feeder Protection 4. Motor Protection 5. Interlock & Isolator Logic 6. Switchyard, Switchgear commissioning .

Relays Handled

IN SEL

SEL751A- Feeder protection SEL 710,749 – Motor protection SEL 787 – Transformer differential protection

IN MICOM

Micom P632 – Transformer Protection. Micom P141 – Feeder Protection. Micom P143 – Feeder Protection Micom P546 – Distance Protection & Line differential

IN ABB

REF615- Feeder Protection

Page 2: new resume

IN SIEMENS

7UT613 - Transformer protection 7SS52 - Busbar protection 7UM62 - Generator protection 7SA611 - Distance protection 7SJ64 - Bay Control Unit 6MD86 - Bay Control Unit 7SD52 - Line Differential 7SK802 - Feeder protection Relay 7SJ801 - Motor protection Relay

SIEMENS REYROLLE

7SR242 - Transformer protection Relay 7SR200 - Feeder protection Relay

Relay Software Tools

ABB - PCM 600( Ver. 2.6).AREVA - Micom S1 Studio, agileSEL - SELSIEMENS - DIGSI 4.87, 4.89,5 SIEMENS REYROLLE - Reydisp Evolution

Test Kit Handled

Conventional Kit:

Omicron (CMC-256, CMC-356) Doble F6150 Ponovo

Switchyard & Switchgear kits

CT Primary injection kit (up to 5kA)-Sudharsan PT Primary injection kit (up to 5kV)-Sudharsan Insulation Resistance Tester (up to 5kV DC)-Kyoritsu Hi-Pot kit (up to 70kV)-Anandjyothi Transformer Winding Resistance Kit – Scope TRM 104 Time interval meter for breaker – Scope MXP Contact Resistance kit for breaker – Scope 100B, 100C Vibration Meter ,Noise Meter, Temperature Meter, Tacho Meter Earth Tester, LCR Meter . Single phase relay test kit.

Page 3: new resume

Schemes handled

ALSTOM L&T SIEMENS BHEL NR ABB C&S GE

Clients/Sites handled

Generating Power Station, Refinerys,Substations

RPCL Power plant( RAICHUR,KARANATAKA)

Testing of Numerical Relays of all HT Motors, Feeders ,Transformers in the power plant.

IOCL Paradip Refinery project (PARADIP, ORISSA)

Testing and commissioning of all primary electrical equipment in panels ,Stackers at Rating of 11kV/6.6kv,415v.

Testing and commissioning of HT & LT motors up to rating of 8MW.

Testing and commissioning of Transformers up to rating 25MVA.

ADANI COAL MINES (AMBIKAPUR ,CHHATTISGARH)

Testing and commissioning of all primary electrical equipment in panels in 6.6kv, 415v.

Testing and commissioning of HT & LT motors (6.6kv,415v).

Testing and commissioning of Transformers in (6.6kv,415v).

BORL (BINA ,MADHYAPRADESH)

Maintenance Testing of all primary Electrical equipment (CB, CT ,Isolators in 220KV in double bus with transfer bus system) and also includes Micom relays

Rosa Power Plant (SHAHJAHANPUR ,UTTAR PRADESH)

Testing of ABB REF 615, SIEMENS 7SJ64,7UM61,& SEL 710 ,751 relays and the configuration .

Page 4: new resume

UPPTCL ( NIGHASAN ,UTTAR PRADESH)

Configuration and testing of SIEMENS 7SJ64 , 7SA52

Scheme checking for 230 KV line panels, trafo panels,busbar panels, buscoupler panels .

NR ELECTRIC (PANVEL, MUMBAI)

Factory Acceptance Testing /Quality Assurance of Control & Relay panels with voltage rating of( 230KV,132KV,110KV,33KV,11KV).Panels like Line panels, Transformer panels, Bus bar panels, Bus coupler panels, Twin feeders, station automation Panel panels, station Auxiliary panels, synchronizing panels, Bus section panels, capacitor bank panels.etc

GAMESA Wind Power Generation (URAVAKONDA, ANDHARAPRADESH)

Scheme checking for 230 KV line panels, trafo panels, busbar panels, buscoupler panels .

Scheme checking for 33 KV twin feeders .

Testing & commissioning of 33 KV twin feeders .

Configuration and testing of SIEMENS 7SJ64 , 7SA52,7SD52 ,7UT613.

VEDANTA POWER (GOA)

Maintenance Testing of SIEMENS, 7UM62,7SJ801,7Sk802 (Generator protection ,Motor Protection, Feeder Protection).

SAINT GOBAIN (CHENNAI)

Configuration and testing of SIEMENS 7SJ801 Feeder Protection Relay.

TS TRANSCO (SIDDIPET ,TELANGANA)

Testing & configuration SIEMENS Reyrolle Relay 7SR242,7SR220,7RW80.7SJ801.

Scheme checking for 220KV trafo feeders .

Page 5: new resume

Personal Details

Name : Balakrishnan.A

Father’s name : Anandhakrishnan.G

Address : 10A,rajambal nagar, manjakuppum, Cuddalore Dt.

Email.id : [email protected]

Phone no : +91-9943247554

Dob : 30/07/1989

Gender : Male

Nationality : Indian

Languages known : English, Tamil, Hindi. Present organization : SUN&JAY Engineering Consultants Pvt.Ltd.

Passport No : L6185657

Date :

Place: (BALAKRISHNAN.A)