New United Steel Ductile Plus 500E mesh does more than meet
the building standards that apply from 1 February 2012. With thicker wire, wider spacing and new sheet sizes, Ductile Plus
500E is also easier to move and install.
www.unitedsteel.co.nz
NEW MESH MAKES YOUR SLABS
Tougher in a quake& quicker to makeTougher in a quake& quicker to make
NEW MESH MAKES YOUR SLABS
6262L
73 DE73 L.DE
• Allconstructionmesheshavedoubleedgebarstooptimisethenetcoverofthesheets
• TherequiredlapasperAS/NZS3101:2006Clause8.6.2(square+50mm:with150mmlapasmin)
• Sheetsindividuallytagged
• Testcertificatesavailable
• IndependentlytestedtoverifycompliancetoAS/NZS4671:2001Ductility500Estandards
• Grade500E(seismic)asperAS/NZS4671
• TensileRatio(Rm/Re)1.15to1.40
• Uniformelongation(Agt):min10%
Ductile Plus 73DE, 73LDE Mesh
• 300mmBarspacingforeasy‘stepthrough’ while placing and working on site
• Easylappingwithdoubleedgeconfiguration
Ductile Plus 73LDE only:• Large14.49m2 nett cover for less wastage in lapping=cheaperpersquaremetre
• SE62Plus—Easytotransport size5.03x2.02
• SE62L—Larger6.05x2.42 meshsizetomaximisehandling and lapping
DesignedtomeettheDepartmentofBuilding&Housing(DBH)newB1Compliancestandard,withequivalentmassto2.27kg/m2.Weldstrengthimprovedby22%(for6.1mm)and100%(for7.5mm)comparedtothe5.3mmwire usedfor665mesh.
Ductile Plus 62 & 62L Mesh
DUCTILE PLUS RESIDENTIAL MESH
*Diagram not to scale
*Diagram not to scale
250mm
150mm
300mm
200mm
75mm
50mm
75mm
6262L
73 DE73 L.DE
MESH PROPERTIES
92DE
72DE82DE93DE
92DE
72DE82DE93DE
Main Wire Diameter
Edge Wire Diameter
Bar Spacing
Edge Wire Spacing Length Width Nett
CoverageKN per
metre widthMass
per m2Sheet weight
RESI
DEN
TIA
L SE62 6.1mm - 200mm - 5.05m 2.02m 8.31m2 73.1 2.30kg/m2 24.8kg
SE62L 6.1mm - 200mm - 6.05m 2.42m 12.363m2 73.1 2.30kg/m2 35.25kg
SE73DE 7.5mm 5.5mm 300mm 75 5.00m 2.27m 10.08m2 73.6 2.31kg/m2 29.1kg
SE73LDE 7.5mm 5.5mm 300mm 75 7.10m 2.27m 14.49m2 73.6 2.31kg/m2 40.5kg
CON
STRU
CTIO
N SE72DE Plus 7.0mm 5.5mm 200mm 75 6.40m 2.37m 13.64m2 96.2 3.02kg/m2 48.45kg
SE82DE Plus 8.0mm 5.5mm 200mm 75 6.40m 2.37m 13.64m2 125.7 3.95kg/m2 61.82kg
SE92DE Plus 9.0mm 6.1mm 200mm 80 6.41m 2.38m 13.64m2 159.0 4.99kg/m2 78.30kg
SE93DE Plus 9.0mm 6.1mm 300mm 75 6.80m 2.27m 13.86m2 106.0 3.33kg/m2 54.95kg
OurrangeofconstructionmeshesarebasedonthespecificationsofthelistinAS/NZs4671:2001withsome additionalmeshestofillsomegaps.
Ductile Plus 92DE Mesh
Ductile Plus 72DE & 82DE & 93DE Mesh
*Diagram not to scale
*Diagram not to scale
150mm
160mm
see mesh table for details
200mm
75mm
80mm 80mm
75mm
DUCTILE PLUS CONSTRUCTION MESH
MESH TABLE Choice of wire and sheet sizes in the Ductile Plus range
CONVERSION CHART FOR MESHES
United Steel is best placed to serve• Industryknowledge–AsNewZealand’sleadingmanufacturer,ourcloseworkingrelationshipsacrossthe industry give United Steel a great understanding of what matters to you.
• Innovation–UnitedSteelcontinuestoinvestheavilyinR&Dandproducttesting,soyoucanrelyonusto keep delivering a comprehensive range of products you need.
• Quality–Ourdesignsandmanufacturingplantsarestateoftheart,offeringtopquality.
• Costefficiency–Becauseourmeshdesignsarefocusedonmaximisingcoverage,UnitedSteelproductsareverycosteffective.
• NZmade–UnitedSteelinvestsintheNewZealandeconomy,creatingjobsandmakinguseofselectedlocally sourced recycled steel.
• Customerservice– United Steel has a proven track record of delivering proactive customer service for over 20 years.
TofindoutmoreaboutUnitedSteelDuctilePlus500Evisitwww.unitedsteel.co.nz Toplaceyourordercalluson0800 800 649 or email [email protected]
23 TRUGOOD DRIVE EAST TAMAKI AUCKLAND
1454A OMAHU ROAD HASTINGS HAWKES BAY
218A DE HAVILAND DRIVE BELL BLOCK NEW PLYMOUTH
9B PETERKIN STREET WINGATE LOWER HUTT
22 MCALPINE STREET SOCKBURN CHRISTCHURCH
OLD HARD DRAWN WIRE MESHES @ 485MPA
STRENGTH LADDER
NEW DUCTILE PLUS 500E MESH RANGE
OLD DUCTILE MESHES 430 SERIES 390MPA
WIREDIAMET
ER
SPAC
ING
CRO
SSSEC
TION
KN/M
WIDTH
MES
HES
KN/M
ETRE
WIDTH
WIREDIAMET
ER
SPAC
ING
CRO
SSSEC
TION
KN/M
ETRE
WIDTH
MES
HES
WIREDIAMET
ER
SPAC
ING
CRO
SSSEC
TION
KN/M
ETRE
WIDTH
MES
HES
175 10.0 175 448.8 175.0 MDT-430-450*
170
165
160 9.0 200 318.1 159.0 SE92
155 10.0 200 392.7 153.2 MDT-430-400
9.0 215.0 295.9 143.5 295* 150
7.5 150.0 294.5 142.8 661 140
135 10.0 225 349.1 136.1 MDT-430-350
9.0 240.0 265.1 128.6 265* 130
7.1 150.0 263.9 128.0 662* 125 8.0 200 251.3 125.7 SE82
120 10.0 250 314.6 122.7 MDT-430-300
110 9.0 300 212.1 106.0 SE93
9.0 300.0 212.1 102.8 212 100
6.3 150.0 207.8 100.8 663 95 7.0 200 192.4 96.2 SE72 8.0 210 239.4 93.4 MDT-430-240
90
6.0 150.0 188.5 91.4 664* 85 8.0 225 223.4 87.1 DTM225*
7.5 235.0 188.0 91.2 188* 80 8.0 250 201.1 78.4 MDT-430-200
75 7.5 300 147.3 73.6 SE73
5.3 150.0 147.1 71.3 665 70 6.1 200 146.1 73.1 SE62 7.0 225 171.0 66.7 DTM170*
7.5 235.0 147.3 71.4 147 60 7.0 250 153.9 60.0 MDT-430-150*
5.3 50.0 441.2 214.0 225 55
4.0 150.0 83.8 40.6 668 50
5.6 300.0 82.1 39.8 84 40
*Denotesmeshnolongeravailableex-stock /madetoorderonly