NEW MAXUM RERV-S200 RHRV-S200A RHRV-S200P HEAT & … · • Power ratings: 115V / 1 / 60 Hz, 1.5...
Transcript of NEW MAXUM RERV-S200 RHRV-S200A RHRV-S200P HEAT & … · • Power ratings: 115V / 1 / 60 Hz, 1.5...
SENSIBLE CHOICE TO IMPROVE YOUR INDOOR AIR QUALITY & HEALTHY LIVING
Slim line compact units
Tilted core design for maximum efficiency
HEAT & ENERGY RECOVERY VENTILATORS
MAXUMNEW
RHRV-S200ARHRV-S200PRERV-S200
790 Rowntree Dairy Road, Woodbridge, ON Canada L4L 5V3 Tel: 905.851.6701 Fax: 905.851.8376Toll Free: 1.800.810.3473 (Canada) / 1.866.890.6457 (U.S.A.) www.reversomatic.com [email protected]
2
FEATURES
S 2
HRVs are recomended for colder climates.ERVs are designed for warm-humid climates with long cooling seasons.
U.S. Department of Energy climate zones map
Maxum Unit S 2S 2
• Over all size 23” (W) x 23” (D) x 12.25 ” (H)
• Power ratings: 115V / 1 / 60 Hz, 1.5 Amp., Standby current is 7W only
• Washable Enthalpy core and Filters
• Drainless design
• High efficiency energy saving permanently lubricated
variable speed PSC motors for air balancing
• Suitable for horizontal & vertical installation
• Tilted core design for maximum efficiency
• Automatic fan cycled defrost
• Exhaust up to four washrooms
• Suitable for Corridor
• Two Speed exhaust (High / Low) - up to 225 CFM maximum
• Continuous fresh air supply at Normal speed up to 150 CFM
• Furnace / Fan-coil / the Heat Pump Interlock
• Dual Protection: If exhaust fan fails, the outside fresh-air supply will be closed
by shutting off the supply motor and the relay contact for the motorized damper
and interlock will be opened. Fan Coil/Furnace low speed will be stopped and at
normal operation no air will enter into the system
• In case of power failure, optional motorized spring return damper
stops the fresh air intake and prevents the core from freezing
• Weight approximately 52 lbs., 2 years warranty on parts
All models have Tilted core design that provides the most efficient drainage for horizontal installation
These HRV / ERVs are especially designed for house to provide constant fresh air into the living room and bedrooms while exhausting same amount of stale air from the washrooms and kitchen. The low speed exhaust is constantly provided through the balancing box located in the washrooms or kitchen. The high speed can be achieved to remove excessive humidity and odours by initiating the switches located in the washrooms. All units are equipped with state of the art fan cycled defrost mechanism. These units are equipped with a sophisticated control that can be used in conjunction with Furnace.
23”
6” dia.
ElectricalBox
1 ½”
jtantay 10/10/10
12 ”14/
120V Motorized spring return backdraft damper (option-2)
Drain
23”
Built-in motorized spring return damper(Option-1)
Air Filters
PolypropyleneBackdraft damper
Temp. Sensor
PolypropyleneBackdraft damper
Balancing Ports
PUSH FOR FAN
M I N U T E S
LO HI INT
(IC 100-5V)Intermittent Switch
Low/High/Intermittent/Offmode.In Intermittent mode, HRV/ERV runs for 20 min. in low speed & 40min. OFF.and cycles Continuously.
ACCESSORIES
FLAT - ADF 26
PROJECT - ADP 28
J03L
TA
NT
AY
02/
16/1
1
DETACHABLE - ADD 28
Double Vent withSide Exhaust / Intake(DVS-100)
Double Vent withExtruded AluminumGrillesExhaust and Intake (DVG-200)Optional:Stamped Aluminum Grilles
Double Vent for window panelExhaust and Intake (DV-200)
DVV-100 - c/w Vertical
Double Vent Exhaust / Intake hood
DehumidistatWall-mount unit allows to control indoor humiditylevel. Suitable for Superior Series & Compact Units.(RH100)
PUSH FOR FAN
M I N U T E S
Electronic Timer Switch (5V DC)Activates the unit on high speed for 20, 40, 60 minutes.Suitable for Deluxe,Superior & Compact Units. (TC100)
Single Vent (SVI) with Aluminum Grille Optional:Extruded Aluminum Grille
Standard Stamped
Intake vent
Single Vent (SVE) with Extruded Aluminum Grille (RSVG100) Optional:Stamped Grille
Exhaust vent
Motorized Damper 5 inch diameter spring return round damper
NSPRD024-5 (24V DC)& SPRD110-5 (110V AC)
Access Doors
Time Delay Switch (120V AC) Activates the unit on high speed for 5-30 minutes.Suitable for SuperiorSeries and Compact Units. (TC100-120)
Time Delay Switch (120V AC) 24 Hour Programmable Timer.Suitable for SuperiorSeries and Compact Units. (TC100-120P)
VENTILATION PERFORMANCE
Heating
Cooling
0
0
0
0
35
32
32
32
32
95
30
37
48
63
63
78
101
133
1.01
1.04
1.02
1.03
76
85
96
112
69
67
65
62
84
81
78
73
1 %
2 %
0 %
1 %
RHRV-S200A
I
ii
iii
iv
v
vi
30-25 -13 63 0.96* 75 62 82 2 %
ENERGY PERFORMANCE
----
----
----
----
Heating
Cooling
0
0
0
0
35
32
32
32
32
95
24
32
44
67
50
67
94
141
1.01
1.06
1.06
1.03
64
76
90
118
72
71
69
65
86
85
78
74
RHRV-S200P
I
ii
iii
iv
v
vi
Heating
Cooling
0
0
0
0
35
35
32
32
32
32
95
95
31
51
69
85
31
50
65
107
146
180
65
107
1.04
1.01
1.05
0.97
1.00
0.97
78
106
130
156
78
110
74
73
70
68
56**
51**
89
84
82
78
76
75
58 %
54 %
47 %
45 %
56 %
47 %
RERV-S200
I
ii
iii
iv
v
vi
vii
* The Supply / Exhaust Flow Ratio at 22°C to the start of the 72 Hour Cold Weather Test** Indicate Total Recovery Efficiency not Sensible Recovery Efficiency
MaximumPower Rating120V / 1 / 60Hz
1.50 Amp.
Model#
RHRV-S200A
Normal SpeedSupply/Exhaust
(Constant Ventilation)@ 50 Pa
50 ~ 150 CFMvariable
High SpeedExhaust
(Activated by switch)@ 50 Pa
100 ~ 225 CFMvariable
RHRV-S200P
RHRV-S200
50 ~ 150 CFMvariable
50 ~ 150 CFMvariable
100 ~ 225 CFMvariable
100 ~ 225 CFMvariable
1.50 Amp.
1.50 Amp.
(Also available w/o OFFmode)
Wall Grille
or
Wall/Ceiling Diffuser
Above the Snow line
Above the Snow line
Above the Snow line
120V Motorized spring return backdraft damper (Recommended)
HOUSE
120V Motorized spring return backdraft damper (Recommended)
Rev(4.0), 11/14/16
FRESH AIR / EXHAUST AIR VENTS INSTALLATION
Double Vent (DVG-200) c/w extruded aluminum grilles Re - Circulation Efficiency - 95%
Double Vent (DVS-100)c/w side Exhaust / Intake hood Re - Circulation Efficiency - 98%
Above the Snow line
Note: All Exhaust Vents must be installed min. 5 ft away from sidewalls.
Double Vent (DVV-100C)c/w vertical Exhaust / Intake hood Re - Circulation Efficiency - 98%
*Specially designed for Project Condo units.
Exhaust (SVE-50) & Intake (SVI-50) vents c/w extruded aluminum grilles Re - Circulation Efficiency If distance “X” is 5ft - 99.7% “X” is 3ft - 96.5%
Above the Snow line
(tested @ 5-10 mph wind velocity)
Fully Ducted System
HRV with Fan Coil System
FRESH AIR
EXHAUSTED AIR
Motorized springreturn backdraft damper(Recommended)
Motorized springreturn backdraft damper(HighlyRecommendeddue to chimney or stack effect)
790 Rowntree Dairy Road, Woodbridge, ON Canada L4L 5V3 Tel: 905.851.6701 Fax: 905.851.8376Toll Free: 1.800.810.3473 (Canada) / 1.866.890.6457 (U.S.A.) www.reversomatic.com [email protected]
Note: