  • DOMESTIC & COMMERCIALFans for domestic and commercial use

    DOMESTIC & COMMERCIAL Catalogue 16

  • O.ERRE: this acronym has been our name for over 60 years. A story built day-by-day, project-by-project, with perseverance and humility. We owe everything to the air that is not seen but sensed: within the nature of this noble uid are the hidden secrets of our intuitions.

    Whether were talking about air lters or fans, hand- or hairdryers, our core interests are air movement and how to make it naturally ow.

    Our curiosity constantly pushes us forward and makes us go deeply into things, with a genuine desire to offer something better, new, distinctive: this is O.ERREs philosophy.

    Ignition system, ease of installation, design or energy recovery: it doesnt matter where ideas for new products come from, what is important to us is how to get great results.

    Thanks to its attitude O.ERRE is highly respected and well known primarily by its customers and suppliers, but also by distributors, installers and above all the end user.

    Only those who achieve results through the quality of their products and are proud of their history can have the enthusiasm and motivation to take on new challenges.

    Factory in Trezzano Rosa (Milan)

    3

  • INDEX

    Ventil/Ventimatic 28

    Ventilor 29

    Smart 30

    Diverso 36

    Diverso IN 38

    Silente 40

    Compact 42

    AXIAL WINDOW FANS

    CENTRIFUGAL FANS

    IN (Low Pro le) 10

    IN 9/3,5 12

    TB 15

    IN BB 16

    IN A 22

    Standard 13

    IN BB A 25

    Standardmatic 24

    Minimatic 26

    AXIAL FANS

    AUTOMATIC AXIAL FANS

    AXIAL AUTOMATIC FANSWITH BALL BEARING

    AXIAL FANS WITH BALLBEARING MOTOR

    Tempero 34

    Outdoor 44

    Aspirodor 165 48

    Aspirodor 46

    Domestic & Commercial accessories 50

    DOMESTIC & COMMERCIAL

    Mini 20

    CROMO 18

    4

  • 5Ball bearing Energy saving

    Low noise ratio

    Rotating body

    Double inlet

    Operating warning light

    No dust on the wall

    Low pro le

    Orientedoutlet air

    Wi-

    No dust on the wall

    Internal shutter

    IPX5 protected

    The product conforms to applicable EEC Directives Working temperature 45C

    Product protected against splash proof Russian mark for electrical safety

    Product approved by I.M.Q. (Italian Institute of Quality Mark)

    Product with double electrical insulation

    In line air outlet or at 90

    SYMBOLS AND ABBREVIATIONS

    CHROME

    Chromecover

    Back-draught shutter

    BB Ball bearing motor M Manual T Timer H Humidistat HT Humidistat with Timer

    PIR Presence infra red sensor PC Pull cord SELV Safety Extra Low Voltage (12V)

    GUIDE TO AIR EXTRACTION

    IPX4

    T 45

    The air quality in con ned spaces (indoor), can cause different unpleasant effects reactions from general malaise to more serious complications on health status. Experts have widely shown that huge concentrations of pollutants like tobacco, smoke, sweat, formaldehyde, carbon monoxide (CO2),

    radon, etc... can be found in work environments, in public of ces, commercial buildings.To improve the quality of air we breath, it is necessary to ven-tilate the rooms where people live and carry out their several activities. Hence the need to install a fan.

    VENTILATING THE ROOMS

  • GUIDE TO AIR EXTRACTION

    6

    The recommended air changes here below have to be considered as an approximate indication only. For further information please refer to the local country rules.The following values are drawn from Prospect 111 contai-ned in UNI 10339:95 standard. The values in m/h were obtained from corresponding values in l/s (multiplying the value by 3,6) and have been rounded. Depending on the type of the room is possible to obtain the necessary air exchange (m/h) it is for every single environment as stated in the Table.

    The calculation based on the crowd, is carried out multiplying the exchanges per person (m/h)

    by the number of persons present are presented in the referred premises; The calculation based on the surface, is carried out multiplying the changes (m/h x m) by the surface of the same premises; The calculation based on the volume, is obtained by multiplying the value in table by the cubic of the premises in (m).

    The air must be extracted from technical areas such as kitchens, bathrooms, services and therefore must be kept in vacuum.

    CALCULATING THE AIR FLOW

    CHOOSING THE RIGHT FAN

    Fans are divided into three main categories, differing in Power, installation and type of application.

    For a correct ventilation is essential requirement chosing the suitable product in accordance with the main features of the premises and type of application. The table shown in the following pages indicates the criteria how to x the required ow rate in any condi-tion. For duct installation considering losses of load, please refer to the table following the criteria as stated.

    Axial fansAxial fans moving large air volumes at low pressure.Suitable for wall and window mounting for direct air extraction or through short lenght ducting.

    In line centrifugal fansCentrifugal fans equipped with centrifugal impeller to convey the air in axial instead of radial direction from the same structure of the pro-duct. Able to generate high pressures and designed to be installed at any point along ducting.

    Centrifugal fansCentrifugal fans moving limited air volumes at high pressure.They are able to move the coloumn of air through long ducting overcoming the resistance curve, narrow passages and irregularitiesof the inner surfaces. Suitable for installation in long and tortuous ducting.90

  • 7 SCHOOL BUILDINGS

    Nursery school 4 14 Primary school 5 18 Junior high School 6 22 Secondary school 7 25 University 7 25 Services 8 Libaries, reading rooms 6 22 Music room 7 25 Laboratories 7 25 Teachers room 6 22

    PUBLIC BUILDINGS

    SPORTS BUILDINGS

    COMMERCIAL BUILDINGS

    Of ces Of ce 11 40 Open space 11 40 Meeting rooms 10 36 Data processing center 7 26 Services 8

    Cinema, theaters, Public areas, rooms (no smoking) 5,5 20 conference halls Stages, TV studio 12,5 45 Meeting rooms (smokers) 10 36 Services 8 Stock market 10 36 Waiting rooms 8 museums, libraries Exhibition halls 6 22 and places of worship Reading rooms 5,5 20 Book stores 1,5 6 Worships, churches 6 22 Services 8 Bars, restaurants, Bars 11 40 ballrooms Pastry shops 6 22 Dining rooms 10 36 Ballrooms 16,5 60 Kitchens 16,5 Services

    Swimming pool, sauna Swimming pool 2,5 Dressing room, Services 8 Sauna 2,5 Gyms Sports halls 6,5 23 Bowling 10 36 Playing elds 16,5 59 Spectator areas 6,5 23 Changing rooms, services 8 Public services 8

    Department stores Basements 9 33 Upper oors 6,5 24 Shops and departments Barbers, hairdressers 14 51 Clothing, footwear, furniture, opticians, orist, photographers 11,5 42 Foodstuffs, dry cleaners, pharmacies 9 33 Areas of public banks, 10 36 exhibition centers

    Rooms 11 40 Wards 11 40 Sterile environment 11 40 Medical rooms, Living room 8,5 31 Physical therapy 11 40 Services 8

    HOSPITALS, CLINICS, NURSING HOMES

    CALCULATING THE AIR FLOW RATE

    TABLE FOR AIR REPLACEMENT Rooms category Air ow rate

    Houses Bed rooms, Living rooms 11 40 Kitchens, Bathrooms, Services 4 Flat Meeting rooms 9 33 Bed rooms 11 40 Kitchens, Bathrooms, Services 16,5 60 Bathrooms, Services 4 Hall, Living rooms 11 40 Hotels Meeting rooms 5,5 20 Dining rooms 10 36 Bed rooms 11 40 Bathrooms 4 Services 8

    Ref. No. People Ref. m Ref. Volume Air changes per person Air changes per m Air changes per hour l/s m/h l/s m/h

    RESIDENTIAL BUILDINGS

  • 68

    Diagram for fan choice

    Duct diameter in mm

    Pressure losses in mm HO per meter of duct

    Air

    sp

    eed

    m/s

    ec

    Flo

    w r

    ate

    m/

    h

    How to use the Diagram:1) Start with the ow rate value (m3/h) on the right side of the diagram.2) Proceed horizontally until you cross the diagonal line giving you the diameter of the duct you need. 3) Descend vertically to nd the value of the pressure loss expressed in mm H2O per each metre of duct.Multiply this value with the required lenght of pipe and you will nd the total pressure loss value. If you want the value in PA, multiply the value with 9,81.At the intersection of the ow rate and duct diameter values, follow this line upwards until it intersects with the recommended air speed (m/sec). Once you have this value refer to Table A.

    LOSSES FOR BENDS AND ELBOWS

    Speed m/sec 1 2 3 4 5 6 7 8 9 10 15 20 30 Pressure loss for bend (mm HO) 0,01 0,05 0,1 0,2 0,3 0,4 0,5 0,7 0,9 1,1 2,5 4,5 10 Pressure loss for elbow (mm HO) 0,1 0,35 0,8 1,4 2 3 4 5,5 7 9 20 35 65

    Table A

    GUIDE TO AIR EXTRACTION

  • AXIAL FANS

  • LowPro le

    10

    AXIAL FANS

    Axial fans to extract air directly outside or through

    ducting also suitable for window application through

    window kit accessory;

    Slim grille with operating warning light;

    Click assembly;

    Two xing screws to allow easy installation;

    For ducts 100-120-150 mm;

    Versions : Standard, Timer, PIR, HT, 12 V;

    Extremely high performances, low noise and power

    consumption;

    IPX4 protected & working temperature 45C.

    Accessories pages 50, 53-54

    Performance and noise tests on product samples (In 10/4, In 12/5, In 15/6 models) carried out by IMQ

    Clima laboratory; Careful selection of components: ABS + lled

    polypropylene; Double insulated product, electrical grounding does

    not required; Reduced internal wall dimensions to allow installation

    where the bend of ducting is close to the outlet of the product; Very high performances in terms of ow rate, low dB (A)

    and low power consumption due to a precise study of optimisation of motor-impeller combination; Voltage: 220-240V, 50Hz; In accordance with Standard EN 60335-2-80; Performance tests in accordance with Standard UNI 10531. Noise tests in accordance with Standard UNI EN ISO 3741.

    This is the SELV (Safety Extra Low Voltage) version working at 12V AC. of the axial fan model IN 10/4. This fan can be installed within the saftey zones 1 and 2,

    as de ned by the Standard IEC 364-7 part 7, where the risk related to electrical connections is very high.

    The very low power voltage of the IN 10/4 SELV, in com-bination of a dedicated transformer supplied with the fan, allows the installation even in proximity of the bath tub

    or the shower, because the eventual direct contact with the fan does not pose any threat of electrical danger.

    The supply unit must be installed within zone 3. Please refer to page 21 for a detailed explanation of the meaning of the different safety zones.

    Wallmounting

    Ceiling mounting

    Windowmounting

    IPX4 T 45

    FURTHER INFORMATION

    SELV 12 V

    Fixing clip Operating warning light

    240 cm

    60 cm

    225

    cm

    SELV UNIT

    ZONE 3

    ZONE 1

    ZONE 2

    Low pro le

    Operating warning light

  • 11

    5

    10

    30

    25

    20

    15

    00 12040 60 80 10020

    Pa

    m/h

    IN 10/4

    Flow rate

    Pre

    ssur

    e

    10

    70

    40

    50

    60

    30

    20

    00 200 250 300 350100 15050

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN 15/6

    5

    10

    50

    30

    35

    45

    40

    20

    25

    15

    00 120 140 160 180 20040 60 80 10020

    Pa

    m/h

    IN 12/5

    Flow rate

    Pre

    ssur

    e

    SELV 12 V

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max (m3/h) (mm H2O) Pa Power W

    IN 10/4 SELV 12 V 0055700 100 220-240 105 2,8 28 15 35,6 0,5 IN 10/4 SELV 12 V Timer 0055800 100 220-240 105 2,8 28 15 35,6 0,5 IN 10/4 SELV 12 V HT 0055900 100 220-240 105 2,8 28 15 35,6 0,5 IN 10/4 SELV 12 V Pull Cord 0056000 100 220-240 105 2,8 28 15 35,6 0,5

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max (m3/h) (mm H2O) Pa Power W

    IN 10/4 0050100 100 220-240 105 2,8 28 13 35,6 0,5 IN 10/4 T 0050700 100 220-240 105 2,8 28 13 35,6 0,5 IN 10/4 HT 0054300 100 220-240 105 2,8 28 13 35,6 0,5 IN 10/4 PIR 0054600 100 220-240 105 2,8 28 13 35,6 0,5 IN 12/5 0050200 120 220-240 180 4,6 45 18 38,8 0,6 IN 12/5 T 0050800 120 220-240 180 4,6 45 18 38,8 0,6 IN 12/5 HT 0054400 120 220-240 180 4,6 45 18 38,8 0,6 IN 12/5 PIR 0054700 120 220-240 180 4,6 45 18 38,8 0,6 IN 15/6 0050300 150 220-240 330 6,2 61 30 42,2 0,8 IN 15/6 T 0050900 150 220-240 330 6,2 61 30 42,2 0,8 IN 15/6 HT 0054500 150 220-240 330 6,2 61 30 42,2 0,8 IN 15/6 PIR 0054800 150 220-240 330 6,2 61 30 42,2 0,8

    DIMENSIONIDIMENSIONS

    Model A B C D EIN 10/4 160 160 53 18 100IN 12/5 180 180 53 19 120IN 15/6 210 210 66 20 150

    A

    B

    C D

    E

  • 12

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN 9/3,5

    5

    10

    30

    25

    20

    15

    00 8040 50 60 7010 20 30

    9/3,5

    Axial fans to extract air directly outside;

    High performances, low noise and power

    consumption;

    For ducts with diameter less than 100 mm;

    Reduced dimensions granting easy mounting

    in uncomfortable positions;

    Timer version, adjustable from 3 to 25 minutes;

    High performances/noise level ratio;

    Protection grade: IPX4;

    Working temperature 45C.

    Accessories page 53-54

    Exit spigot diameter 92 mm; Made of bright ABS material; Performance and noise tests on product samples

    carried out by IMQ Clima laboratory; Careful selection of components: ABS + lled

    polypropylene; Double insulated product, electrical grounding does

    not required; Voltage: 220-240V, 50Hz; In accordance with Standard EN 60335-2-80.

    IPX4 T 45

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    IN 9/3,5 0055500 92,5-100 220-240 75 2,8 28 11 31,6 0,4 IN 9/3,5 T 0055600 92,5-100 220-240 75 2,8 28 11 31,6 0,4

    Low Pro le

    DIMENSIONS

    Model A B C DIN 9/3.5 121,5 92 63 21IN 9/3.5 T 121,5 92 63 21

    Low Pro le

    FURTHER INFORMATION

    Wallmounting

    Ceiling mounting

    AXIAL FANS

  • 13

    Axial fans to extract air and fumes directly outside;

    Optional window kit (except Standard 8);

    For duct: 80-100-120-150 mm;

    Panel mounting through locking ring (100 & 120);

    Versions: Base, Timer;

    Timer version adjustable from 2 to 25 minutes

    (Standard 8 supplied with Timermatic);

    Pull Cord version: on/off through Pull Cord;

    IPX4 protected.

    Accessories pages 50, 53- 54

    Grille made of bright ABS material; Performance and noise tests on product samples carried out by IMQ Clima laboratory; Careful selection of components: ABS + lled polypropylene; Double insulated product, electrical grounding does

    not required; Voltage: 220-240V, 50Hz; In accordance with Standard EN 60335-2-80.

    STANDARD

    IPX4 Except Pull-CordversionsOnly 10 and12 model

    Standard 8 Timer with TIMERMATIC included.

    Standard Pull Cord.Switching on/off through a pull cord.

    FURTHER INFORMATION

    Wallmounting

    Ceiling mounting

    Windowmounting

    T 45

  • 14

    STANDARD

    30

    25

    20

    15

    10

    5

    00 10 20 30 9040 50 60 70 80

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    STANDARD 10

    45

    40

    35

    30

    25

    20

    15

    10

    5

    00 25050 100 150 200

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    STANDARD 15

    35

    30

    25

    20

    15

    10

    5

    0 m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    STANDARD 12

    0 20 40 60 80 100 120 140

    2

    1

    4

    5

    7

    6

    3

    00 10 15 20 25 30 355 40

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    STANDARD 8

    DIMENSIONIDIMENSIONS

    B

    A

    C D

    E

    Model A B C D EStandard 8/8T 123 123 58 24 75Standard 10/10T/10 Pull Cord 154 154 45 34 98Standard 12/12T/12 Pull Cord 174 174 45 34 118Standard 15/15T 210 210 62 40 146

    TECHNICAL DATA Model Code. Hole Volt Flow Rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    STANDARD 8 0084700 80-100 220-240 35 1 9,8 15 36 0,4 STANDARD 8 T 0084800 80-100 220-240 35 1 9,8 15 36 0,4 STANDARD 10 0015700 100 220-240 85 2,6 26 13 32 0,5 STANDARD 10 T 0015900 100 220-240 85 2,6 26 13 32 0,5 STANDARD 10 Pull Cord 0017500 100 220-240 85 2,6 26 13 32 0,5 STANDARD 12 0015800 120 220-240 125 3,0 29 13 33 0,65 STANDARD 12 T 0016000 120 220-240 125 3,0 29 13 33 0,65 STANDARD 12 Pull Cord 0094700 120 220-240 125 3,0 29 13 33 0,65 STANDARD 15 0016100 150 220-240 230 4,2 41 30 41 1 STANDARD 15 T 0016400 150 220-240 230 4,2 41 30 41 1

    AXIAL FANS

  • 15

    TB

    In-line axial fans to extract or intake air or as a booster

    to increase air ow in an existing installation;

    Body and impeller made of polypropylene material;

    Induction motor impedence protected on TB 10

    and with thermal protection on TB 12 & TB15;

    Low consumption and low noise

    IPX4 protected.

    Accessories pages 53-54

    IPX4

    10

    30

    25

    35

    20

    15

    0

    5

    0 40 5030 60 702010 80 90m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    TB 10

    10

    40

    50

    60

    30

    70

    20

    00 100 25020015050 300

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    TB 15

    10

    40

    35

    30

    25

    45

    20

    15

    0

    5

    0 40 6020 80 100 120 140 160m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    TB 12

    TECHNICAL DATA Model Code Duct Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    TB 10 0018400 100 220-240 85 3,0 30 15 42 0,5TB 12 0019400 120 220-240 150 4 39 15 43 0,6

    TB 15 0019500 150 220-240 265 6,1 60 25 50 0,7

    DIMENSIONS

    A

    B

    C A

    Model A B CTB 10 96 97 55TB 12 116 97 55TB 15 147 113 55

    AXIAL FANS Long life

    Wallmounting

  • BB

    Axial fans to extract air directly outside

    or through ducting;

    Optional kit for window installation;

    Ball bearing motor;

    Click assembly of the fan;

    Two xing screws for easy installation;

    For ducts: 100-120-150 mm;

    Versions: Base, Timer;

    High perfomances, noiseless & low comsumption;

    IPX4 protected;

    Working temperature 45C.

    Accessories pages 50, 53- 54Ball bearing

    Operatingwarning light

    Low Pro le

    IPX4 T 45

    Performance and noise tests on product samples (In 10/4, In 12/5, In 15/6 models) carried out by IMQ

    Clima laboratory; Careful selection of components: ABS + lled

    polypropylene; Double insulated product, electrical grounding does

    not required; Reduced internal wall dimensions to allow installation where the bend of ducting is close to the outlet of the product; Extremely high performances in terms of ow rate, low dB (A) and low power consumption due to a precise study of optimisation of motor-impeller

    combination; Voltage: 220-240V, 50Hz; In accordance with Standard EN 60335-2-80

    LowPro le

    Fixing clip Operating warning light

    16

    FURTHER INFORMATION

    Wallmounting

    Ceiling mounting

    Windowmounting

    AXIAL FANS Long life

  • Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN BB 15/6

    0

    10

    20

    30

    40

    50

    60

    70

    0 50 100 150 200 250 300 350

    Pa

    m/h

    IN BB 12/5 A

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    0 20 40 60 80 100 120 140 160 180 200

    Flow rate

    Pre

    ssur

    e

    5

    10

    30

    25

    20

    15

    00 12040 60 80 10020

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN BB 10/4

    BB

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    IN BB 10/4 0052500 100 220-240 105 2,8 28 13 35,6 0,5 IN BB 10/4 T 0052800 100 220-240 105 2,8 28 13 35,6 0,5 IN BB 12/5 0052600 120 220-240 180 4,6 45 18 35,8 0,6 IN BB 12/5 T 0052900 120 220-240 180 4,6 45 18 35,8 0,6 IN BB 15/6 0052700 150 220-240 330 6,2 61 30 42,2 0,8 IN BB 15/6 T 0053000 150 220-240 330 6,2 61 30 42,2 0,8

    DIMENSIONIDIMENSIONS

    A

    B

    C D

    E

    Model A B C D EIN 10/4 160 160 53 18 100IN 12/5 180 180 53 19 120IN 15/6 210 210 66 20 150

    17

  • CHROME

    Axial fans to extract air directly outside or through short ducting; Ball bearing motor for long life; Chrome cover matching with all other elements

    and accessories with the same nish; Backdraught shutter; Click assembly of the fan; Two xing screws for easy installation; For ducts: 100 or 120 mm; Versions: Base, Timer, HT; Operating warning light; High performances, noiseless & low consumption; IPX4 protection; Working temperature 45C.Accessories pages 53-54

    Chrome cover

    Operatingwarning light

    Ball bearing

    Back draught shutter

    IPX4 T 45

    Chrome cover Ball bearing motor

    CROMO has been essentially designed, suitable for all conditions and in particularthe cover which matches all the other ele-ments and accessories with the same nish.

    Ball bearing motor ensures stability and with long life. CROMO has a 5 year guarantee.

    CROMOs shutter is in Mylar, which prevents undesired external entry (odours, insects) while turned off. When operating, the shutter opens like a book for natural air extraction. Possibility to remove it.

    While running at a low and non invasive position, CROMO like other O.ERRE products is equipped with a warning system, specically useful to verify optimal running.

    Backdraught shutter Operating warning light

    CROMO re ects your desire for elegance.

    18

    AXIAL FANS Ball bearing motor

    Wallmounting

    Ceiling mounting

  • Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    CROMO 12/5CROMO 12/5 (backdraught shutter)

    5

    50

    25

    40

    45

    30

    35

    20

    15

    10

    00 160100 120 14020 60 8040

    5

    35

    25

    30

    20

    15

    10

    00 1003010 20 60 70 80 9040 50

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    CROMO 10/4CROMO 10/4 (backdraught shutter)

    DIMENSIONS

    A

    B

    CF D

    E

    TECHNICAL DATA Model Code Hole Volt Flow rate max m3/h Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz with shutter without shutter mm H2O Pa Power W

    CROMO 10/4 0052510 100 220-240 80 90 3 30 10 34,6 0,5 CROMO 10/4 T 0052520 100 220-240 80 90 3 30 10 34,6 0,5 CROMO 10/4 HT 0052530 100 220-240 80 90 3 30 10 34,6 0,5 CROMO 12/5 0052610 120 220-240 140 150 4,6 45 16 37 0,6 CROMO 12/5 T 0052620 120 220-240 140 150 4,6 45 16 37 0,6 CROMO 12/5 HT 0052630 120 220-240 140 150 4,6 45 16 37 0,6

    19

    Model A B E C D FCROMO 10/4 170 170 100 53 38 7CROMO 12/5 190 190 120 53 43 7

  • 20

    Axial fans to extract air directly outside

    or through ducting;

    Panel mounting through locking ring;

    Ball bearing motor;

    For ducts: 100-120 mm;

    Versions: Base, Timer, Sensor;

    Timer version adjustable from 2 to 25 minutes;

    Sensor version: with infrared sensor (detects

    presence);

    IPX4 protected.

    Accessories pages 50, 53-54

    MINI

    IPX4 FURTHER INFORMATION

    Mini T - With electronic timer adjustable from 2 to 20 minutes approx; Mini Sensor - The fan automatically starts when the

    infrared sensor detects a presence in the room. When the person leaves the room the fan will conti-nue to run depending on the timer setting. It opera-tes either in the light or in the dark with a radius of 8 metres.

    Particularly suitable for ventilation of rooms in dome-stic and commercial environments.

    DIMENSIONIDIMENSIONSB

    A

    C D

    E

    Model A B C D EMini 10/10T/10 Sensor 154 154 45 36 98Mini 10/10T/10 Sensor 174 174 45 36 118

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    MINI 10 0013700 100 220-240 85 2,6 26 13 32 0,5 MINI 10 T 0014100 100 220-240 85 2,6 26 13 32 0,5 MINI 10 SENSOR 0012100 100 220-240 85 2,6 26 13 32 0,5 MINI 12 0013800 120 220-240 125 3,0 29 13 33 0,65 MINI 12 T 0014200 120 220-240 125 3,0 29 13 33 0,65 MINI 12 SENSOR 0012200 120 220-240 125 3,0 29 13 33 0,65

    MINI 10

    10

    30

    25

    20

    15

    5

    00 902010 50 60 70 8030 40

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    MINI 12

    10

    35

    30

    25

    20

    15

    5

    00 14020 60 80 100 12040

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    Mini Sensor is extre-mely simple to install being connected to the electrical system through two wires, thus eliminating the connec-tions that normally need

    to be made to the light and the light switch. Threaded spigot to allow panel mounting by locking ring.

    T 45

    Ball bearing

    Wallmounting

    Ceiling mounting

    AXIAL FANS Ball bearing motor

  • SELV (Safety Extra Low Voltage) versions can be installed in safety zones 1 and 2 in accordance with the IEC 364- 7 where risk of electrical shock is high. 220240/12V~ transformer, in accordance with IEC 742 class II, IP22 protected with safety thermostat. The very low power voltage of SELV 12V fans, in combination of a dedicated transformer supplied with the appliance, allows the installation even in proximity of the bath tub or the shower, because the eventual direct contact with the fan does not pose any threat of electrical danger. The transformer can be even installed in zone 3. IEC 364-7 standard, Part 7 contains a section dedicated to Locations containing a bath tub or shower basin where stated the risk of electrical shock is increased by a reduction in body resistance and contact of the body with earth potential. In order to avoid such high risk the standard classi es different zones inside the room and for each one it prescribes different installation limits of electrical components. The standard describes the different zones as follows: Zone 0: inside the bath tub or shower basin. Zone 1: is limited by the vertical plane circumscribing the bath tub or shower basin, by the oor and the horizontal plane 2.25 m. above the oor.

    Zone 2: is limited by the vertical plane external to Zone 1 and the parallel vertical plane 0,60 m. external to Zone 1, by oor and the horizontal plane 2,25 m. above the oor. Zone 3: is limited by the vertical plane external to Zone 2 and the parallel vertical plane 2,40 m. external to Zone 2, by oor and the horizontal plane 2,25 m. above the oor. For each zone the standard makes a list of the prescriptions for the electrical equipment that may be or may not be installed as follows: In zone 0, only electrical appliances specially intended for use in a bath tub are permitted. In zone 1, only water heaters or SELV type appliances (Safety Extra Low Voltage) may be installed. In zone 2 only water heaters, and Class II luminaires or SELV type appliances may be installed. In zone 3 there are no limits for installation of electrical equipment, but anyway the eventual Switchgear and Controlgear must be as follows: supplied individually by an isolating transformer, supplied by SELV, protected by a residual current protective device with a residual operating current not exceeding 0,03 A. Hence, in zone 1 or 2 or 3 only a 12 V SELV fan should be installed.

    21

    SELV VERSIONS: FOR SAFE INSTALLATIONS

    240 cm

    60 cm

    225

    cm

    SELV UNIT

    ZONE 3

    ZONE 1

    ZONE 2

    104,

    8

    124,8 67

    Transformer dimensions (supplied with the fan)

  • 22

    Axial fans to extract air directly outside

    or through ducting;

    Optional kit for window installation;

    Grille provided with internal automatic shutter;

    Click assembly of the fan;

    Two xing screws for easy installation;

    For ducts: 100-120-150 mm;

    Versions: Base, Timer, PIR, HT;

    High perfomances, noiseless & low consumption;

    IPX4 protected;

    Working temperature 45C.

    Accessories pages 50, 53-54

    A

    Operatingwarning light

    Internalshutter

    IPX4 T 45

    APPROFONDIMENTI

    Performance and noise tests on product samples (In 10/4, In 12/5, In 15/6 models) carried out by IMQ

    Clima laboratory; Careful selection of components: ABS + lled

    polypropylene; Double insulated product, electrical grounding does

    not required; Reduced internal wall dimensions to allow installation

    where the bend of ducting is close to the outlet of the product;

    Very high performances in terms of ow rate, low dB (A) and low power consumption due to a precise study of optimisation of motor-impeller combination;

    Voltage: 220-240V, 50Hz; In accordance with Standard EN 60335-2-80

    Operating warning light Internal shutter

    Wallmounting

    Ceiling mounting

    Windowmounting

    AXIAL FANS Ball bearing motor

  • DIMENSION

    23

    A

    5

    10

    15

    30

    25

    20

    00 12040 60 80 10020

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN 10/4 A

    10

    20

    70

    60

    50

    40

    30

    00 400200 250 300 35050 100 150

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN 15/6 A

    5

    15

    10

    20

    25

    45

    40

    35

    30

    00 200120 140 160 18040 60 80 10020

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN 12/5 A

    Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    TECHNICAL DATA

    IN 10/4 A 0050400 100 220-240 110 2,8 28 16 35,6 0,6 IN 10/4 A T 0051600 100 220-240 110 2,8 28 16 35,6 0,6 IN 10/4 A HT 0051900 100 220-240 110 2,8 28 16 35,6 0,6 IN 10/4 A PIR 0052200 100 220-240 110 2,8 28 16 35,6 0,6 IN 12/5 A 0050500 120 220-240 185 4,6 45 21 38,8 0,7 IN 12/5 A T 0051700 120 220-240 185 4,6 45 21 38,8 0,7 IN 12/5 A HT 0052000 120 220-240 185 4,6 45 21 38,8 0,7 IN 12/5 A PIR 0052300 120 220-240 185 4,6 45 21 38,8 0,7 IN 15/6 A 0050600 150 220-240 340 6,2 61 33 42,2 0,9 IN 15/6 A T 0051800 150 220-240 340 6,2 61 33 42,2 0,9 IN 15/6 A HT 0052100 150 220-240 340 6,2 61 33 42,2 0,9 IN 15/6 A PIR 0052400 150 220-240 340 6,2 61 33 42,2 0,9

    DIMENSIONIDIMENSIONS

    Model A B C D EIN 10/4 A 160 160 53 42 100IN 12/5 A 180 180 53 43 120IN 15/6 A 210 210 66 44 150

    A

    B

    E

    C D

  • 20

    15

    10

    35

    40

    45

    30

    25

    0

    5

    0 100 15050 200 250m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    StandardMatic 15

    10

    25

    30

    35

    20

    15

    0

    5

    0 20 40 60 80 140120100m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    StandardMatic 12StandardMatic 10

    STANDARDMATIC

    Axial fans to extract air directly outside

    or through ducting;

    Panel mounting through locking ring ( 10 & 12);

    Low motion and noiseless opening of shutter;

    For ducts: 100-120-150 mm;

    Versions Base, Timer;

    Timer version adjustable from 2 to 25 minutes;

    IPX4 protected.

    Accessories pages 50, 53-54

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    STANDARDMATIC 10 0016600 100 220-240 90 2,6 26 16 32 0,7 STANDARDMATIC 10 T 0016700 100 220-240 90 2,6 26 16 32 0,7 STANDARDMATIC 12 0016800 120 220-240 130 3,0 29 16 33 0,85 STANDARDMATIC 12 T 0016900 120 220-240 130 3,0 29 16 33 0,85 STANDARDMATIC 15 0017000 150 220-240 230 4,2 41 30 41 1,2 STANDARDMATIC 15 T 0017100 150 220-240 230 4,2 41 30 41 1,2

    IPX4

    FURTHER INFORMATION

    In accordance with EN 60335-2-80; Grille made of bright ABS material; IPX4 protected for areas with high humidity; 10 - 12 for installation on panel through the dedicated locking ring.

    Silent and slow shutter operation.

    Model A B C D EStandardmatic 10/10T 154 154 45 51 98Standardmatic 12/12T 174 174 45 51 118Standardmatic 15/15T 210 210 62 54 146

    B

    A

    C D

    E

    DIMENSIONIDIMENSIONS

    T 45

    24

    ExceptStandardmatic 15-15T

    AXIAL FANS Automatic - Wall mounting

    Wallmounting

    Ceiling mounting

    Windowmounting

  • Axial fans to extract air directly outside or through ducting; Optional kit for window installation; Grille provided with internal automatic shutter; Click assembly of the fan; Ball bearing motor; For ducts: 100-120-150 mm; Versions: Base, Timer, PIR, HT; High perfomances, noiseless & low consumption; IPX4 protected; Working temperature 45C.Accessories pages 50, 53-54

    BB A

    Ball bearing

    Internal shutter

    IPX4 T 45

    25

    AXIAL FANS Long life - Automatic - Wall mounting

    FURTHER INFORMATION

    Performance and noise tests on product samples (In 10/4, In 12/5, In 15/6 models) carried out by IMQ Clima laboratory;

    Careful selection of components: ABS + lled polypropylene;

    Double insulated product, electrical grounding does not required;

    Reduced internal wall dimensions to allow installation where the bend of ducting is close to the outlet

    of the product; Extremely high performances in terms of ow rate,

    low dB (A) and low power consumption due to a precise study of optimisation of motor-impeller

    combination; Voltage: 220-240V, 50Hz; In accordance with Standard EN 60335-2-80

    Operating warning light Internal shutter

    Operating warning light

    Wallmounting

    Ceiling mounting

    Windowmounting

  • DIMENSIONS

    26

    AXIAL FANS Long life - Automatic - Wall mounting

    10

    20

    70

    60

    50

    40

    30

    00 400200 250 300 35050 100 150

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN BB 15/6 A

    5

    10

    15

    30

    25

    20

    00 12040 60 80 10020

    Pa

    m/h

    IN BB 10/4 A

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    IN BB 12/5 A

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    0 20 40 60 80 100 120 140 160 180 200

    Flow rate

    Pre

    ssur

    e

    A

    B

    E

    C D

    Model A B C D EIN 10/4 A 160 160 53 42 100IN 12/5 A 180 180 53 43 120IN 15/6 A 210 210 66 44 150

    TECHNICL DATA Model Code Hole Volt Flow rate Max press Max press Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    IN BB 10/4 A 0053100 100 220-240 110 2,8 28 16 35,6 0,6 IN BB 10/4 A T 0053400 100 220-240 110 2,8 28 16 35,6 0,6 IN BB 10/4 A HT 0053700 100 220-240 110 2,8 28 16 35,6 0,6 IN BB 10/4 A PIR 0054000 100 220-240 110 2,8 28 16 35,6 0,6 IN BB 12/5 A 0053200 120 220-240 185 4,6 45 21 38,8 0,7 IN BB 12/5 A T 0053500 120 220-240 185 4,6 45 21 38,8 0,7 IN BB 12/5 A HT 0053800 120 220-240 185 4,6 45 21 38,8 0,7 IN BB 12/5 A PIR 0054100 120 220-240 185 4,6 45 21 38,8 0,7 IN BB 15/6 A 0053300 150 220-240 340 6,2 61 33 42,2 0,9 IN BB 15/6 A T 0053600 150 220-240 340 6,2 61 33 42,2 0,9 IN BB 15/6 A HT 0053900 150 220-240 340 6,2 61 33 42,2 0,9 IN BB 15/6 A PIR 0054200 150 220-240 340 6,2 61 33 42,2 0,9

  • IPX4

    MINIMATIC

    Axial fans to extract air directly outside

    or through ducting;

    Panel mounting through locking ring ( 10 & 12);

    Ball bearing motor;

    Low motion and noiseless opening of shutter;

    For ducts: 100-120-150 mm;

    Versions: Base, Timer;

    Timer version adjustable from 2 to 25 minutes;

    IPX4 protected.

    Silent and slow shutter operation

    In accordance with EN 60335-2-80; Grille made of bright ABS material; IPX4 protected for areas with high humidity.

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press Max press Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    MINIMATIC 10 0018500 100 220-240 90 2,6 26 16 32 0,7 MINIMATIC 10 T 0018600 100 220-240 90 2,6 26 16 32 0,7 MINIMATIC 12 0018700 120 220-240 130 3,0 29 16 33 0,85 MINIMATIC 12 T 0018900 120 220-240 130 3,0 29 16 33 0,85 MINIMATIC 15 0084500 150 220-240 230 4,2 41 30 41 1,2 MINIMATIC 15 T 0084600 150 220-240 230 4,2 41 30 41 1,2

    20

    15

    10

    35

    40

    45

    30

    25

    0

    5

    0 100 15050 200 250m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    MiniMatic 15

    10

    25

    30

    35

    20

    15

    0

    5

    0 40 6020 80 140120100m/h

    Pa

    MiniMatic 12MiniMatic 10

    Flow rate

    Pre

    ssur

    e

    Model A B C D EMinimatic 10/10T 154 154 45 51 98Minimatic 12/12T 174 174 45 51 118Minimatic 15/15T 210 210 62 54 146

    B

    A

    C D

    E

    27

    T 45 ExceptMinimatic 15-15T

    DIMENSIONS

    FURTHER INFORMATION

    Ball bearing

    Wallmounting

    Ceiling mounting

    Windowmounting

  • 28

    DIMENSIONS

    AXIAL FANS Window mounting

    VENTIL & VENTIMATIC

    IPX4

    Axial fans to extract air directly outside

    or through ducting;

    Window or panel mounting up to 10 mm;

    Low motion and noiseless opening of shutter

    (Ventimatic); manual opening through Pull Cord

    (Ventil);

    Rain proof external grille;

    Optional kit for double glazing installation;

    IPX4 protected.

    Accessories pages 53-54

    Grille made of bright ABS material; In accordance with EN 60335-2-80;

    Windowmounting

    Silent and slow shutter operation(Ventimatic range).

    Ventil and Ventimaticseries supplied withanti-vibration gasket.

    FURTHER INFORMATION

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press Max press Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    VENTIL 10 0084000 135-145 220-240 70 2,2 22 13 33 0,9 VENTIL 12 0084100 155-165 220-240 100 3,0 29 13 34 1 VENTIL 15 0084200 186-195 220-240 155 4,0 39 30 42 1,6 VENTIMATIC 10 0011000 135-145 220-240 70 2,2 22 16 33 0,9 VENTIMATIC 12 0011100 155-165 220-240 100 3,0 29 16 34 1 VENTIMATIC 15 0011200 186-195 220-240 155 4,0 39 30 42 1,6

    5

    15

    20

    25

    10

    45

    40

    35

    30

    00 20 6040 18080 140 160100 120

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    Ventil - Ventimatic 15

    5

    15

    20

    25

    10

    35

    30

    00 20 6040 12080 100

    m/h

    Pa

    Ventil - Ventimatic 12Ventil - Ventimatic 10

    Flow rate

    Pre

    ssur

    e

    B

    A

    C D

    A Model A B C DVentil 10 - Ventimatic 10 154 154 77 29Ventil 12 - Ventimatic 12 174 174 74 29Ventil 15 - Ventimatic 15 210 210 99 29

  • VENTILOR

    Axial fans to extract air and fumes directly

    outside;

    Windows, double glazing and panels up

    to 50 mm mounting;

    Optional wall xing kit & double glazing kit;

    Low motion and noiseless automatic shutter;

    20/8 M Manual opening through Pull Cord;

    Operating warning light (except on 20/8 M);

    Rain proof external grille;

    Adjustable speed with optional controller RG 5 AR.

    Accessories page 51

    Windowmounting

    In accordance with EN 60335-2-80; Made of bright ABS material.

    Quick and simple installationand maintenance bylocking ring which givessome tolerance on the holesize in the glass.

    Reversible air- ow,extraction and ventilation for 20/8 AR and25/10 AR models.

    20

    140

    120

    100

    40

    60

    80

    00 50 150100 500200 400 450250 350300

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    Ventilor 20/8

    10

    70

    60

    50

    20

    30

    40

    00 100 800200 400 500 600 700300

    m/h

    Pa

    Ventilor 25/10

    Flow rate

    Pre

    ssur

    e

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press Max press Rated dB (A)3m Kg mm max m3/h mm H2O Pa Power W

    VENTILOR 20/8 M 0018800 225-235 220-240 - 50/60 Hz 450 12 118 50 58 2,4 VENTILOR 20/8 AR 0019000 225-235 220-240 - 50/60 Hz 450 12 118 50 58 2,4 VENTILOR 25/10 AR 0019200 275-285 220-240 - 50/60 Hz 750 6,0 59 60 45 5,6

    DIMENSIONS

    B

    A

    C D

    Model A B C DVentilor 20/8 M - 20/8 AR 280 280 94 30Ventilor 25/10 AR 335 335 128 33

    29

    FURTHER INFORMATION

    Operating warning light

  • 30

    SMART

    Axial fans to extract air directly outside

    or through ducting;

    Optional kit for window installation;

    Grille provided with internal automatic shutter;

    Click assembly of the fan;

    Ball bearing motor;

    For ducts: 100-120-150 mm;

    Versions: Base, Timer, PIR, HT;

    High perfomances, noiseless & low consumption;

    IPX4 protected;

    Working temperature 45C.

    Accessories page 51

    Wall

    Wi-

    Internal shutter

    Except Smart 23/9 Wall

    Provided with integral automatic shutter preventing undesired air back- ow when the unit is turned off.

    The Wi-Fi version is provided with a radio transmitter for functions operation.

    In accordance with EN 60335-2-80.

    Reversible air- ow,extraction andventilation for (AR version)

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm max m3/h mm H2O Pa Power W

    SMART 15/6 M 0072800 184-195 220-240 - 50 Hz 230 5,1 50 30 40 1,3 SMART 15/6 A 0072700 184-195 220-240 - 50 Hz 230 5,1 50 30 40 1,3 SMART 23/9 M 0072100 254-262 220-240 - 50/60 Hz 750 6,6 65 40 43 3,7 SMART 23/9 AR 0072000 254-262 220-240 - 50/60 Hz 750 6,6 65 40 43 3,7 SMART 23/9 AR Wall 0072600 254-262 220-240 - 50/60 Hz 750 6,6 65 40 41 3,7 SMART 23/9 AR Wi Fi 0071600 254-262 220-240 - 50/60 Hz 750 6,6 65 40 43 3,7 SMART 23/9 AR Silent 0072500 254-262 220-240 - 50/60 Hz 500 2,5 25 30 33 3,7 SMART 30/12 AR 0071400 324-337 220-240 - 50/60 Hz 1350 12 118 75 49 6,6 SMART 30/12 AR Wi Fi 0071800 324-337 220-240 - 50/60 Hz 1400 8,2 80 60 46 6,1 SMART 30/12 AR Silent 0071300 324-337 220-240 - 50/60 Hz 1000 5,1 50 45 39 5,6

    Ball bearing

    FURTHER INFORMATION

    AXIAL FANS Window mounting

    Wallmounting

    Ceiling mounting

  • SMART

    30

    20

    10

    50

    60

    70

    40

    00 100 300 400 500 600 700200 800

    m/h

    Pa

    Smart 23/9 M/AR Wall - Wi.Fi

    Flow rate

    Pre

    ssur

    e

    20

    10

    40

    50

    60

    30

    00 400 600 1000800200 1200

    m/h

    Pa

    Smart 30-12 AR Silent

    Flow rate

    Pre

    ssur

    e

    20

    10

    70

    40

    50

    60

    80

    90

    30

    00 400 600 1000800200 16001200 1400

    m/h

    Pa

    Smart 30-12 AR - Wi.Fi

    Flow rate

    Pre

    ssur

    e

    Smart 23/9 AR Silent

    10

    20

    25

    30

    5

    15

    00 100 300 400 500200 600

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    Smart 15/6 M/A

    20

    40

    50

    60

    10

    30

    00 50 100 150 200 250

    m/h

    Pa

    Flow rate

    Pre

    ssur

    e

    DIMENSIONS DIMENSIONS

    Model A B C D wall/glass Hole glass thickness15/6 A-M 215 215 100 30 184195 32023/9 M-AR-Silent-Wi Fi 321 331 141 30 254262 35030/12 AR-Silent-Wi Fi 375 385 148 30 324337 350

    B

    A C

    D

    Model A B C D 23/9 AR Wall 424 434 242-316 30

    B

    A C

    D

    31

  • 32

    The fan, operated by a wireless radio control (Wi-Fi) and only requires the connection to the electric systems (L-N).The remote control (included) is supplied with 12V DC battery and fully operates the products functions (on-off, reversibility and 3 speed regulation).The remote control can easily be installed to the wall or panel with two small screws.Being a radio transmitting control, it is not necessary to point it directly towards the fan and operates within a maximum range of 30 meters.The polished design of the Wi-Fi radio transmitter perfectly integrates with the other elements of the electric installation.

    Big tolerance on the window glass diameter hole, which allows to overcome to some cutting errors or adapt the fan to any existing hole.All models from the SMART series are suitable for installation on single, double glazing window glass or wood panel.

    Easy and quick installation on window glass through a special assembly xing system by click springs and nal screw blocking

    Easy removal of the front grille by untightening the 2 safety screws and with a simple nger pressure on both fan sides.

    Easy and fast installation on windowthanks to two xing screws only,with an original clicking and pluginsystem. No screws required to block the connection cable.

    Smart 23/9 e 30/12

    Smart 15/6Quote for installation on glass SMART

    Quote for installation SMART WALL SMART Wi Fi

    Model I Vel II Vel III Vel IV Vel V VelSmart 23/9 AR Silent 200 250 350 420 500Smart 23/9 M-AR-Wall 280 370 510 640 750Smart 30/12 AR 600 840 1050 1200 1400Smart 30/12 AR Silent 400 500 650 820 1000

    Flow rates m/h (with controller RG5 AR)

    Model A mm B mm C mm D mmSmart 15/6 184195 108 108 325Smart 23/9 254262 210 230 350Smart 30/12 324337 245 245 350

    SMART

    375 mm

    242 mm316 mm

    385

    mm

    B

    AC

    AXIAL FANS Window mounting

  • CENTRIFUGAL FANS

  • CENTRIFUGAL FAN Energy recovery

    TEMPERO

    Fan provided with an energy recovery system;

    Ideal for domestic application and suitable

    for single room;

    Wall and /or panel mounting;

    Cross Flow Air Exchanger welded PVC plates;

    Two centrifugal fans;

    Filters in polyurethane to grant higher

    protection and longer function;

    Operating warning light on all the models;

    Pre-heating system (PH model only) consists

    of a 350 W coil with thermostat, tted

    in a box of self extinguishing material;

    Versions: base, timer & pre-heater for cold climates;

    On/off and adjustable speed with optional

    controller RG 5.

    Accessories pages 53- 54

    Energy saving

    IPX4 Tempero100 e 100T

    Operating warning light

    Temper contributes to achieve Class of Energy

    Wallmounting

    Body made of white ABS with inner components in polypropylene; Single speed; High performance in terms of balance between

    energy recovery, consumption, ow rate and noise level;

    In accordance with EN 60335-2-80.

    Tempero 100Basic version suitable for climatesand temperatures between 5 C and +35 C.Tempero 100 TSame main features of the basic versionwith added Timer control.Tempero 100 PHSuitable for outdoor minimum temperatures of 25 C.

    Tempero can be easily installed on new or existing ducts (diameter 100/200 mm).Possibility of renovating old/non functional fans thus granting a healthier and better indoor environment with minimal or no invasive procedure to the building structure.

    Extracted air stream transfers thermal energy to the fresh incoming air, rst through the surface of the PVC ducting pipe and of the motors heat and then through the cross ow plates heat recovery core located into the unit.

    Tempero is supplied with a PVC ducting pipe(diameter: 63mm), which should be tted internally to the existing duct (diameter 100/120 mm) up to a maximum wall depth of 400 mm. If the depth of wall exceeds 400 mm a replacement pipe is required.

    34

    FURTHER INFORMATION

  • TEMPERO

    120

    100

    20

    40

    60

    80

    00 805040302010 60 70

    TEMPERO 100 INTAKETEMPERO 100 EXTRACTION

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    TECHNICAL DATA Model Code Hole Volt Flow rate IN Flow rate OUT Max press. Rated dB (A)3m Kg mm at 50 Hz m3/h m3/h Pa Power W

    TEMPERO 100 0068400 100-120 220-240 60 70 100 40 34 3,3 TEMPERO 100 T 0068500 100-120 220-240 60 70 100 40 34 3,3 TEMPERO 100 PH 0068600 100-120 220-240 60 70 100 400 34 3,3

    DIMENSIONS

    A

    B

    C

    D

    Model A B C DTempero 100 257 400 155 179Tempero 100 T 257 400 155 179Tempero 100 PH 257 400 155 179

    Tempero is an extractor fan provided with an energy recovery system ideal for single room domestic applications. It offers healthier and better indoor environment by moderating the temperature of the incoming air plus economic advanta-ges due to energy saving.

    The ow of extracted air transfers thermal energy to the fresh incoming air, rst through the surface of the internal ductingpipe tted into the existing duct and then through the cross ow plates heat recovery core located in the unit. During this process the incoming and outgoing air ows are completely separated.During winter season, Tempero guarantees an ef cient energy recovery of up to 70%.During summer season, Tempero reduces substantially the energy required for air conditioning.

    Suitable for wall applications, it can be easily tted to 100 and 120 mm new or existing ducts, offering the opportunity to renovate, substituting old/non functioning axial fans without further invasive procedures to the building structure.The heat recovery core of PVC cross ow plates is equipped with two easily removable lters for simple and regular cleaning.

    Tempero has been conceived and designed to work as a usual air extractor fan with the advantage of added energy conservation. In normal conditions Tempero will not produce enough con-

    densation to require drainage.It has been equipped with a dedicated condensation drainagehole thus eliminating the build up of excess condensation related to the certain environmental conditions (temperature, humidity...) and/or continuous use.

    Tempero has been designed to work also in cold climates of 25C, thanks to a pre-heating coil available for the PH modelonly. The Tempero PH model pre-heater, is a 350 W coil tted in the ducting pipe. When the outside temperature falls below 5C a thermostat activates the coil thus heating incoming air to about 15-20C avoiding ice build-up on the recovery module.

    35

  • Centrifugal fans to extract air and fumes through

    ducting or pipes from 80 mm diameter;

    Suitable for wall/ceiling mounting even through

    ducts in awkward places thanks to the position

    of the outlet hole in the corner;

    Ball bearing motor;

    Integral backdraught shutter;

    Easy cleaning of washable lter;

    IPX5 protected;

    Double speed;

    Adjustable speed through RGE or RG 5 controller

    (basic version only).

    Accessories pages 53-54

    No duston the wall

    Rotating body

    Ball bearing

    IPX5 protected T 45

    Elegant design, suitable for all conditions; Body made in white ABS. In compliance with EN 60335-2-80.

    Balancing grille for easy cleaning of lter.

    washable lter

    Diverso has been produced to grant a high protection rating (IPX5)becoming the right choice for application in humid environmentsand in presence of sprinklings of water. This situation, typical in environments such as bathrooms and kitchens, requires a highly protected product that can grant the maximum safety to the end user.

    Timer and HT operations

    TimerWhen switched on, the fan will start rotating after 5 sec and will overrunafter being switched off according to the pre-set timer period.Adjustable overrun timer from 2 min up to 30 min.Standard setting 15 min.

    The rotating body allows air extraction from different spigot positions

    HTThe fans start automatically when the humidity level in the rooms is higher than the pre-determined humidity level on the potentiometer which allow to adjust from 40% to 90%.With manual operation the fan operates as timer version.

    No dust on the wallDiverso, characterized by soft and fair design, has been produced to integrate nicely in the surrounding environment by avoiding leaving dust deposits on the wall that normally happens using a common fan with side air inlet.Diverso has been produced to work in a different way.The common exhaust fans allow the air exchange through frontal or side air inlet. Diverso operates in a different way combining both functions to get higher bene ts and reduce any disadvantage.Diverso operates by frontal air inlet through an outside leak duly shaped to create a whirlpool to prevent the air from creeping against the surrounding wall.This is to avoid dust deposits appearing on the wall resulting in the need to redecorate.

    36

    CENTRIFUGAL FAN Wall or ceiling mounting

    FURTHER INFORMATION

    Wallmounting

    Ceiling mounting

    Windowmounting

  • DIVERSO 80 Low SpeedDIVERSO 80 High Speed

    Pa

    m/h

    20

    200

    100

    160

    180

    120

    140

    80

    60

    40

    00 9050 60 70 8010 30 4020

    Flow rate

    Pre

    ssur

    e

    450

    100

    250

    300

    350

    400

    150

    200

    50

    00 300100 150 200 25050

    Flow rate

    DIVERSO 240 Low SpeedDIVERSO 240 High Speed

    Pre

    ssur

    e

    Pa

    m/h

    350

    100

    250

    300

    150

    200

    50

    00 18060 80 100 120 140 16020 40

    DIVERSO 160 Low SpeedDIVERSO 160 High Speed

    Pa

    m/h

    Flow rate

    Pre

    ssur

    e

    DIMENSIONS

    Model A B C D E FDiverso 80 244 117 75,5 20 55 55Diverso 160 300 148 96,7 20,5 60 65Diverso 240 300 148 96,7 20,5 60 65

    DIVERSO 80 0081700 80-100 220-240 80 60 18 16 177 157 28 18 40 36 1,5 DIVERSO 80 T 0081800 80-100 220-240 80 60 18 16 177 157 28 18 40 36 1,5 DIVERSO 80 HT 0081900 80-100 220-240 80 60 18 16 177 157 28 18 40 36 1,5 DIVERSO 160 0082000 100 220-240 170 120 30 25 294 245 50 35 42 36 2,7 DIVERSO 160 T 0082100 100 220-240 170 120 30 25 294 245 50 35 42 36 2,7 DIVERSO 160 HT 0082200 100 220-240 170 120 30 25 294 245 50 35 42 36 2,7 DIVERSO 240 0082300 100 220-240 240 140 43 30 422 295 80 45 47 38 2,9 DIVERSO 240 T 0082400 100 220-240 240 140 43 30 422 295 80 45 47 38 2,9 DIVERSO 240 HT 0082500 100 220-240 240 140 43 30 422 295 80 45 47 38 2,9

    Model Code Hole Volt Flow rate m3/h Max press. mm H2O Max press. Pa Rated Power W dB (A)3m Kg mm at 50 Hz max min max min max min max min max min

    TECHNICAL DATA

    37

  • IPX5 protected

    Ball bearing

    Rotating body

    Centrifugal fans to extract air and fumes through

    ducting or pipes from 80 mm diameter;

    Suitable for wall/ceiling mounting in awkward

    places thanks to the outlet hole in the corner;

    Built-in version;

    Ball bearing motor;

    Outlet hole adjustable in 2 positions;

    Integral backdraught shutter;

    Easy cleaning of washable lter;

    Double speed;

    Adjustable speed through RGE or RG 5 controller

    (basic version only).

    Accessories pages 52, 53-54

    No dust on the wall

    T 45

    Elegant design, suitable for all conditions; Body made of white ABS. Outlet hole adjustable in 2 different positions In compliance with EN 60335-2-80.

    Easy removal of washable lter thanksto the balancing grille.

    The rotating body allows air extraction from different spigot positions.

    Timer and HT operations

    TimerWhen switched on, the fan will start rotating after 5 sec and will overrunafter being switched off according to the pre-set timer period.Adjustable overrun timer from 2 minup to 30 min.Standard setting 15 min.

    Diverso has been produced to grant a high protection rating (IPX5)becoming the right choice for application in humid environments and in presence of sprinklings of water.This situation, typical in environments such as bathrooms and kitchens, requires a highly protected product that can grant the maximum safety to the end user .

    No dust on the wallDIVERSO, characterized by soft and fair design, has been produced to integrate nicely in the surrounding environment by avoiding leaving dust deposits on the wall that normally happens using a commonfan with side air inlet. Diverso has been produced to work in a diffe-rent way. The common exhaust fans allow the air exchange through frontal or side air inlet. Diverso operates in a different way combining both functions to get higher bene ts and reduce any disadvantage.Diverso operates by frontal air inlet through an outside leak duly sha-ped to create a whirlpool to prevent the air from creeping against the surrounding wall. This is to avoid dust deposits appearing on the wall resulting in the need to redecorate.

    HTThe fans start automatically when the humidity level in the rooms is higher than the pre-determined humidity level on the potentiometer which allow to adjust from 40%to 90%.With manual operation the fan operates as timer version.

    38

    Diverso in

    FURTHER INFORMATION

    Wallmounting

    Ceiling mounting

    Windowmounting

    CENTRIFUGAL FAN Wall or ceiling mounting

  • 180

    40

    100

    120

    140

    160

    60

    80

    20

    00 10060 70 80 9010 20 504030

    DIVERSO IN 80 Low SpeedDIVERSO IN 80 High Speed

    m/h

    Pa

    Flow rate

    Pre

    ssur

    e

    500

    450

    100

    150

    250

    200

    300

    350

    400

    50

    00 300200 25050 150100

    DIVERSO IN 240 Low SpeedDIVERSO IN 240 High Speed

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    350

    100

    250

    300

    150

    200

    50

    00 18060 80 100 120 140 16020 40

    DIVERSO 160 Low SpeedDIVERSO 160 High Speed

    Pa

    m/h

    Flow rate

    Pre

    ssur

    e

    DIMENSIONS

    Model A B C D E F G H L M N max

    IN 80 244 238 103,5 17,5 75 18,5 55 55 50 242 29IN 160 300 296 131 25 96,7 18 60 65 66,5 304,5 27IN 240 300 296 131 25 96,7 18 60 65 66,5 304,5 27

    TECHNICAL DATA Model Code Hole Volt Flow rate m3/h Max press. mm H2O Max press. Pa Rated Power W dB (A)3m Kg mm at 50 Hz max min max min max min max min max min DIVERSO IN 80 0082600 80-100 220-240 90 65 17 16 167 157 28 18 38 34 1,5 DIVERSO IN 80 T 0082700 80-100 220-240 90 65 17 16 167 157 28 18 38 34 1,5 DIVERSO IN 80 HT 0082800 80-100 220-240 90 65 17 16 167 157 28 18 38 34 1,5 DIVERSO IN 160 0082900 100 220-240 190 125 35 25 343 245 50 35 40 35 2,7 DIVERSO IN 160 T 0083000 100 220-240 190 125 35 25 343 245 50 35 40 35 2,7 DIVERSO IN 160 HT 0083100 100 220-240 190 125 35 25 343 245 50 35 40 35 2,7 DIVERSO IN 240 0083200 100 220-240 270 150 45 30 442 295 80 45 43 35 2,9 DIVERSO IN 240 T 0083300 100 220-240 270 150 45 30 442 295 80 45 43 35 2,9 DIVERSO IN 240 HT 0083400 100 220-240 270 150 45 30 442 295 80 45 43 35 2,9

    39

    Diverso in

  • SILENTE

    Centrifugal fans to extract air and fumes

    directly outside or through long ducting.

    For ducts with 100, 120 & 150 mm;

    Low sound level with high performance;

    Versions: Base, Timer, HT, Sensor, 12 Volt;

    Easy cleaning of washable lter;

    Gasket made of elastomer for uneven surfaces;

    Quick installation as all components are clicked

    together;

    Centered and reduced air outlet ideal for ducts

    with curves; integral backdraught shutter.

    Accessori pages 51, 53 e 54

    Low noise ratio

    IPX4

    FOR ALL MODELS

    Silente T - With electronic timer adjustable from 2 to 20 minutes; Silente HT - The fan automatically starts when the humidity level in the room is higher than the pre-determined humidity level on the potentiometer which allows to adjust from 40% to 90%; Silente Sensor - The fan automatically starts when the infrared sensor detects a presence in the room.

    When the person leaves the room the fan will continue to run depending on the timer setting; Silente 12 Volt - In addition to the technical and functional features of the basic model it is manufactured with a very low power voltage (SELV).

    Same for Timer version (See page 21); In accordance with EN 60335-2-80.

    Supplied with washable lter assuring long life of the motor and remarkable protection to the impeller,

    With anti-vibration gasket made of elastomer which ts on uneven surfaces and allows installation in holes with diameter 10, 12 and 15 cm. Quick installation as all components are clicked together. The reduced protrusion of the exit spigot allows you to install the unit into ducting with curves placed immediately behind the exit hole.

    Integral backdraught shutter.

    Anti-vibration gasketmade of elastomer.

    Washable lter

    40

    FURTHER INFORMATION

    Wallmounting

    Ceiling mounting

    Windowmounting

    CENTRIFUGAL FAN Wall or ceiling mounting

  • TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    SILENTE 0086500 100-150 220-240 75 12 118 19 36 0,9 SILENTE12 V 0087000 100-150 220-240 60 10 98 15 36 0,9 SILENTE T 0086700 100-150 220-240 75 12 118 19 36 0,9 SILENTE T 12 V 0087100 100-150 220-240 60 10 98 15 36 0,9 SILENTE Sensor 0086600 100-150 220-240 75 12 118 19 36 0,9 SILENTE HT 0086800 100-150 220-240 75 12 118 19 36 0,9

    DIMENSIONS

    B

    A

    C D

    E Model A B C D E

    All SILENTE models 184 184 101,5 8,5 98

    SILENTE 12V

    40

    80

    100

    120

    20

    60

    00 7010 20 40 50 6030

    m/h

    Pa

    Flow rate

    Pre

    ssur

    e

    SILENTE

    40

    100

    120

    140

    80

    20

    60

    00 8010 20 40 50 60 7030

    m/h

    Flow rate

    Pre

    ssur

    e

    Pa

    SILENTE

    41

  • COMPACT

    Centrifugal fans to extract air and fumes directly

    outside or through long ducts.

    For ducts with 100 & 120 mm;

    Suitable for wall/ceiling mounting in awkward

    places thanks to the outlet hole in the corner;

    Versions: Base, Timer, HT, Sensor (Compact100);

    Easy cleaning of washable lter;

    Gasket made of elastomer which ts on uneven

    surfaces;

    Reduced air outlet ideal for ducts with curves;

    Integral backdraught shutter.

    Accessories pages 51, 53 e 54

    Rotating body

    IPX4

    (Except 100 HT, 200 HT, 300 HT e 300 T)

    T 45 (100, 100 T e 100 HT)

    Made of ABS material. Compact T - With built-in electronic timer adjustable from 2 to 20 minutes. Compact HT - The fan automatically starts when the humidity level in the room is higher than the pre-determined humidity level on the potentiometer

    which allows to adjust from 40% to 90%. Compact Sensor - The fan automatically starts when the infrared sensor detects a presence in the room. When the person leaves the room the fan will

    continue to run depending on the timer setting. It operates both the light and the dark with a radius of 8 meters. Thanks to its completely automatic functioning it is suitable for ventilation of rooms in domestic and commercial environments. In accordance with EN 60335-2-80.

    The position of the outlet holein the corner allows installationin dif cult situations.Provided with integral backdraught shutter.

    To allow installation in dif cult corners the front grille has four different xing positions on all sizes excepts for Sensor version.

    Quick installation due to two parts construction,base and front grille/ lter.

    42

    FURTHER INFORMATION

    Wallmounting

    Ceiling mounting

    Windowmounting

    CENTRIFUGAL FAN Wall or ceiling mounting

  • TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    COMPACT 100 0085000 100-120 220-240 85 12,5 123 28 40 1,3 COMPACT 100 T 0085100 100-120 220-240 85 12,5 123 28 40 1,3 COMPACT 100 HT 0093600 100-120 220-240 85 12,5 123 28 40 1,3 COMPACT 100 Sensor 0012300 100-120 220-240 85 12,5 123 28 40 1,3 COMPACT 200 0085200 100-120 220-240 160 20 196 76 45 1,8 COMPACT 200 T 0085300 100-120 220-240 160 20 196 76 45 1,8 COMPACT 200 HT 0093900 100-120 220-240 160 20 196 76 45 1,8 COMPACT 300 0085400 100-120 220-240 250 40 392 95 54 2,3 COMPACT 300 T 0094500 100-120 220-240 250 40 392 95 54 2,3 COMPACT 300 HT 0094200 100-120 220-240 250 40 392 95 54 2,3

    COMPACT

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    COMPACT 100

    40

    60

    80

    20

    140

    120

    100

    00 9040 50 60 70 8020 3010

    Pa

    m/h

    COMPACT 300

    0

    50

    100

    150

    200

    250

    300

    350

    400

    450

    0 50 100 150 200 250 300

    Flow rate

    Pre

    ssur

    e

    50

    250

    200

    150

    100

    00 1804020 100 120 140 16060 80

    Pa

    m/h

    COMPACT 200

    Flow rate

    Pre

    ssur

    e

    DIMENSIONS

    B

    A

    C D

    E

    Modello A B C D E100/100T/100HT 210 210 95 20 97100 Sensor 210 210 95 20 97200/200T/200HT/300/300T/300HT 250 250 111 20 97

    43

  • Guaranteed operating

    -20C + 70C

    IPX5 protected

    Ball bearing

    Centrifugal fan for outdoor mounting;

    Brings outside the tipical noise of the fan;

    External installation frees your internal space;

    The outgoing air ow is 30 inclined in respect

    to the mounting surface so as to avoid dust deposits,

    typical of air ows parallel to the wall;

    Maximum temperature of the extracted air: +70 C;

    Guaranteed operating temperature range

    between -20 C + 70 C;

    Internal damper valve (air & insects);

    Low energy consumption and noise ratio.

    Accessories pages 53-54

    No dust on the wall

    Low noise ratio

    IPX5

    The elegant design and the reduced dimensions minimize visual impact, making it integrable

    in all conditions; Extemely easy installation; Suitable for 100 and 150 mm ducts; Steel painted body and cover in plastic material; Self-cleaning backward curved blade impeller; Speed can be regulated through RGM 2 or RGE

    controllers; In accordance with Standard EN 60335-2-80.

    Wall mounting (External).

    External installation. Extraction single or multi-local.

    44

    CENTRIFUGAL FAN For external mounting

    FURTHER INFORMATION

  • Pa

    m/h

    CO 150

    100

    150

    200

    50

    400

    350

    300

    250

    00 450200 250 300 350 400100 15050

    Flow rate

    Pre

    ssur

    e

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    CO 100

    100

    150

    200

    50

    450

    400

    300

    350

    250

    00 350200 250 300100 15050

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm max m3/h mm H2O Pa Power W

    CO 100 0056100 100 220-240 - 50/60 Hz 300 39 383 55 46 3,6 CO 150 0056200 150 220-240 - 50/60 Hz 400 35 343 60 46 3,6

    45

    Model A B C D E F GCO 100 260 306 114 25 85 96 133CO 150 260 306 114 25 58,5 149 133

    D CA

    F

    G

    B

    E

    FURTHER INFORMATION

  • ASPIRODOR

    Centrifugal fan to extract air and fumes through

    ducts or pipes;

    Double inlet fan;

    Ceiling or wall mounting;

    Horizontal or vertical mounting;

    Gravity shutter to avoid air from getting back in;

    Supplied with installation ange;

    Washable lter included (except for Aspirodor 200).

    Accessories pages 51, 53-54

    Double inlet

    FURTHER INFORMATION

    Made of ABS material;

    For all Aspirodor range, simple main connection via external connector box;

    In accordance with EN 60335-2-80.

    Gravity shutter to avoid air from getting back in.

    The double inlet combines silent operation with highperformance.

    Aspirodor 300 and 400 models, with washable lters to protect moving parts, removable for easycleaning.

    CENTRIFUGAL FANS Double inlet

    46

    Wallmounting

    Duct mounting

  • ASPIRODOR

    Pa

    m/h

    ASPIRODOR 200

    100

    150

    200

    50

    250

    00 250200100 15050

    Flow rate

    Pre

    ssur

    e

    100

    150

    200

    50

    400

    300

    350

    250

    00 450400200 250 300 350100 15050

    Pa

    m/h

    ASPIRODOR 400

    Flow rate

    Pre

    ssur

    e

    100

    150

    200

    50

    300

    250

    00 400200 250 300 350100 15050

    Flow rateP

    ress

    ure

    Pa

    m/h

    ASPIRODOR 300

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. Rated dB (A)3m Kg mm at 50 Hz max m3/h mm H2O Pa Power W

    ASPIRODOR 200 0014500 100-150 220-240 200 21 206 80 49 1,8 ASPIRODOR 300 0014900 100-150 220-240 350 27 265 80 53 2,2 ASPIRODOR 400 0015100 100-150 220-240 400 35 343 80 55 2,8

    DIMENSIONS

    B

    A

    C

    D

    C

    D

    Model A B C D fori ss.Aspirodor 200 205 220 130 160Aspirodor 300 227 245 130 160Aspirodor 400 243 256 130 160

    47

  • ASPIRODOR 165

    Centrifugal fan to extract air and fumes

    through ducts or pipes;

    In-line or angle mounting, by a simple

    adjustment of the frame;

    Supplied with ange for wall mounting;

    Dual purpose spigots suitable for 100 mm

    or 120 mm ducts.

    Accessories pages 53-54

    Made of ABS material; In accordance with EN 60335-2-80.

    Dual purpose spigots suitable for 100 mmor 120 mm ducts.

    Fixing bracket with elongated xing holes to allow positional adjustment.

    Flow rate

    Pre

    ssur

    e

    Pa

    m/h

    ASPIRODOR 165

    100

    120

    140

    160

    180

    20

    40

    60

    80

    200

    00 18016014012010020 40 60 80

    TECHNICAL DATA Model Code Hole Volt Flow rate Max press. Max press. W dB (A) 3m Kg mm at 50 Hz m3/h mm H2O Pa

    ASPIRODOR 165 0016500 100-120 220-240 165 18 177 80 51 1,9

    DIMENSIONS

    B

    A

    C

    D

    E

    F

    E

    F

    Model A B C D E F165 in linea 205 205 263 148 126 102165 ad angolo 205 205 242 148 126 102

    48

    In line air outlet or at 90

    FURTHER INFORMATION

    Wallmounting

    Ductmounting

    CENTRIFUGAL FANS

  • ACCESSORIES

  • ACCESSORIES

    50

    IN series accessories

    Window Kit

    Locking ring

    Air ow de ector

    Window kit

    Kit accessory for window and panel mounting. Window Kit is suitable for installation on a single, double glazing window glass or wood panel, from 3 to a thickness of 20 mm.

    A

    A

    B

    Model Code Suitable for Series A B window hole Window Kit 10/4 0059100 IN 10/4 155 31 132,5145 Window Kit 12/5 0059200 IN 12/5 175 31 152,5165 Window Kit 15/6 0059300 IN 15/6 211 31 186195

    Model Code A B C Ghiera 10 0081400 100 130 40 Ghiera 12 0081500 120 150 40

    Model Code A B C Air ow de ector 10 0069900 90 100 56 Air ow de ector 12 0066200 110 120 65

    Standard, Standardmatic & Minimatic accessories

    Kit accessory for window and panel mounting.Window Kit is suitable for installation on a single, double glazing window glass or wood panel, to a thickness of 10 mm.

    Model Code Suitable for Series window hole Window Kit 10 0087400 Standard - Standardmatic - Mini - Minimatic 10 135145 Window Kit 12 0087500 Standard - Standardmatic - Mini - Minimatic 12 155165 Window Kit 15 0087600 Standard - Standardmatic - Minimatic 15 186195

    Double glazing kitKit composed of set of screws for window up to 25 mm mounting.

    Model Code Suitable for serie Double glazing kit 10-12 0087700 Ventil - Ventimatic 10-12 Double glazing kit 15 0087900 Ventil - Ventimatic 15

    Ventil & Ventimatic accessories

    Standard, Standardmatic & Minimatic Accessories

    C

    BA

    AB

    C

    DOMESTIC & COMMERCIAL ACCESSORIES

  • ACCESSORIES

    51

    Kit double windowKit composed of locking ring and spigot to for double window mounting(i.e.: window environment side, windowsill, window street side).

    Model Code Suitable for series Kit double window 23/9 0079500 Smart 23/9 Kit double window 30/12 0079900 Smart 30/12 Kit double window 20/8 0080400 Ventilor 20/8 Kit double window 25/10 0080500 Ventilor 25/10

    Smart & Ventilor accessories

    Wall xing kit

    Wall xing kit for wall mounting. Suitable for SMART & VENTILOR series.

    Wall xing kit Ventilor 250 mm (20/8) and 300 mm (25/10)

    5 speed reversible controller for Smart & Ventilor series.Accessory to control on/off motor, 5 speed, air ow reversibility. It can be recessed through a dedicated accessory code 0090500.

    Model Code Suitable for series Wall xing kit for 15/6 0079400 Smart 15/6 Wall xing kit for 23/9 0079800 Smart 23/9 Wall xing kit for 30/12 0079800 Smart 30/12 Wall xing kit 0019100 Ventilor

    RG 5 AR

    Model Code Suitable for series RG 5 AR 5 speed reversible controller 0031500 Smart - Ventilor

    Model Code Suitable for series Silente Filter (Blister 4 Pz.) 0086900 Silente Compact 100 Filter (Blister 3 Pz.) 0085600 Compact 100 Compact 200/300 Filter (Blister 3 Pz.) 0085700 Compact 200/300 Aspirodor 300/400 Filter (Blister 2 Pz.) 0081600 Aspirodor 300/400

    Silente, Compact & Aspirodor accessories

    105

    125

    105

    52

  • 52

    Chrome

    Model Code Suitable for series Chrome cover 0082674 Diverso IN 80 Chrome cover 0082974 Diverso IN 160 - Diverso IN 240

    Diverso accessories

    Model Code Suitable for series Gloss anthracite cover 0082671 Diverso IN 80 Gloss anthracite cover 0082971 Diverso IN 160 - Diverso IN 240

    Gloss Anthracite

    Model Code Suitable for series Gloss black cover 0082670 Diverso IN 80 Gloss black cover 0082970 Diverso IN 160 - Diverso IN 240

    Gloss Black

    Model Code Suitable for serie Satin aluminium cover 0082676 Diverso IN 80 Satin aluminium cover 0082976 Diverso IN 160 - Diverso IN 240

    Satin Aluminium

    Model Code Adatto per Serie Satin dark titanium cover 0082672 Diverso IN 80 Satin dark titanium cover 0082972 Diverso IN 160 - Diverso IN 240

    Satin Dark Titanium

    Modello Codice Suitable for series Satin light titanium cover 0082675 Diverso IN 80 Satin light titanium cover 0082975 Diverso IN 160 - Diverso IN 240

    Satin Light Titanium

    Model Code Suitable for series Satin brass cover 0082673 Diverso IN 80 Satin brass cover 0082973 Diverso IN 160 - Diverso IN 240

    Satin Brass

    Diverso IN Cover

    Recessed wall kitRecessed wall kit to provide future installations of DIVERSO IN. Available in two sizes (for DIVERSO IN 80 and DIVERSO IN 160/240). Included with the kit is a temporary insert so as to avoid any mortar or plaster from lling the recessing frame.

    Model Code Suitable for series Recessed wall kit 0082610 Diverso IN 80 Recessed wall kit 0082910 Diverso IN 160 - Diverso IN 240

    DOMESTIC & COMMERCIAL ACCESSORIES

    ACCESSORIES

  • 53

    Accessories

    Self adjusting proportional timer from 4 to 13 minutes approx.It can be used with any fan up to a max power of 200 W.For installation inside switch box, junction box and inside the appliance.

    The Timetronic is an electronic timer designed to delay the turn-off operation of any fan with power as high as 200VA. For installation inside switch boxes or unattended connection.Delay is adjustable from 3 to 25 minutes; no delay is added when the fan starts.

    Model Code Suitable for TIMERMATIC 0033900 All domestic fans (basic version) up to max power of 200 W

    Model Code Suitable for TIMERTRONIC 0034000 All domestic fans (basic version)

    Timermatic

    Timertronic

    Control motor ON/OFF, variable speed and air ow reversibility.They can be recessed through a dedicated accessory - Code 0090500 (on request).

    RGE: Electronic controller with stepless speed. Only for basic fans up to 300 W.RG5: 5 position operating selector. Only for basic fans up to 80 W

    Controllers

    105

    125

    105

    52

    85

    22 19

    28N L

    ~

    Lampada

    Ventilatore

    SW

    MTimerMatic

    16.3

    41

    32.5

    1

    3 25

    14L

    M

    M2M1

    M2M1

    LsN

    L LsN

    39.5

    Model Code Suitable for RGE 0031700 All domestic fans (basic version) RG5 0031400 Domestic fans not reversible Recessed wall kit Controller 0090500 RG5 - RGE

    ACCESSORIES

  • ACCESSORIES

    Rain proof gravity shutter to prevent air from getting back in when the fan is switched off. Shutters automatically open with air ow when the fan is working. Available in different sizes. For external wall mounting.

    Model Code Suitable for SHUTTER 10 0080100 All domestic fans 10 SHUTTER 12 0080300 All domestic fans 12

    Gravity shutter

    Rain proof grille for external wall mounting. Available in different sizes.Completely made of technopolymer.

    Model Code Suitable for GRILLE 10 0080000 All domestic fans 10 GRILLE 12 0080200 All domestic fans 12 GRILLE 15 0090700 All domestic fansi 15

    Grille

    Accessory for all domestic fans (basic version) up to max power of 200W.PIR: The fan automatically starts when the infrared sensor detects a presence in the room. When the person leaves the room the fan will continue to run depending on the timer setting (from 2 up to 25 min). In accordance with EN 60335-2-80.HT: The sensor automatically switches ON/OFF the fan according to the detected level of relative humidity.When humidity level drops the timer takes control keeping the fan operating for a preset time from 2 up to 25 min. Automatic or manual functioning.

    Model Code Suitable for SENSOR HT 0030800 All domestic fans (basic version) up to max power of 200 W SENSOR PIR 0030900 All domestic fans (basic version) up to max power of 200 W

    Sensors

    Accessory suitable for TEMPERO for wall mounting with very reduced thickness such as prefabricated structures,as homes and of ces, containers, shelters, etcThe accessory does not allow the glass mounting.

    Spacer for external grille TEMPERO

    Model A B C D E Spacer 176 155 155 176 65

    A B C D E 149 99 25 70 45 149 119 25 70 45

    A B C D 154 99 43 18 154 119 43 18 208 155 52 28

    A

    A

    C

    B

    DE

    A

    B

    C

    A

    D

    D

    AB

    C

    E

    54

    DOMESTIC & COMMERCIAL ACCESSORIES

  • All products included in this catalogue meet the essential requirements of EU directives.

    In order to improve its offer, O.ERRE reserves the right to change sizes, features and design, or delete entire references of its products without notice.

  • O.ERRE SpA Via Cagliari, 1 20060 Trezzano Rosa - MI ItalyTel. Commercial Dept. +39 02 90 93 18 35 Fax +39 02 92 01 02 61

    [email protected] www.oerre.com

    rggt

    .it