New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site...

57
Ericsson Internal | 2016-08-23 | Page 1 (57) 2016 New DTN Project New baseband And radio system

Transcript of New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site...

Page 1: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 1 (57)

2016 New DTN Project

New basebandAnd radio system

Page 2: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 2 (57)

Safety Equipment

Hand protection

Eye protection

Ear protectionRope Set

and pulleys

Tower Work Set

Full Body Harness with lanyards and

work placement adjusters

Foot protection

Head protection

More detail: See Ericsson HSSE policy

Page 3: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 3 (57)

Tools requiredElectrostatic Discharge (ESD)

wrist strap (static control wrist

strap)

Wire stripper 0.2–6.0 mm

Side cutters

Slip joint pliers

Hammer drill with

depth restrictor

Torque screwdriver 0.5-4.0 Nm / 5–25 Nm Torx T10 / T20 / T25 / T30

Spirit level

Torque wrench 5–25 Nm / 20–100 Nm

Socket 10 mm

Socket 13 mm

Socket 16 mm

Socket 22 mm

Torque wrench 5–100 Nm Open-ended head 32 mm

Open-ended head 16 mm

Open-ended head 18 mm

Crosshead screwdriver Flathead screwdriver

Cleaning

equipment

Page 4: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 4 (57)

New radio system

Radio Available Weight 2G 3G 4G CPRIWCDMA

CarriersIBW Power TX RX

Cascade

TX850 1800 2100

0208 9 Kg. 2x10 Gbps 8 75 MHz 2 2 Q3 Q2

2203 5 Kg. 2x10 Gbps 4 40 MHz 2x5W 2 2 4x4

2212 18 Kg. 2x 2.5/5/10

Gbps 8 75 MHz 2x80W 2 2 2017 2017 2017

2217 10 Kg. 2x10 Gbps 6 40MHz 2x40W 2 2 4x4

2219 17 Kg. 2x 2.5/5/10

Gbps 8 40MHz

2x60W

2x80W2 2 2017 2017 2017

4407 11 Kg.

2x

2.5/5/9.8

Gbps

65 MHz 4x20W 4 4 -

4415 20 Kg. 2x 2.5/5/10

Gbps 8 75 MHz 4x40W 4 4 - 2017 2017 2017

Page 5: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 5 (57)

Macro radio

3xin same volume

Capacity

Smallest footprint

Page 6: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 6 (57)

› 2TX/2RX, 4TX/4RX by use of two 2217

› 2x40W, 40 MHz IBW FDD

Up to › 6 carriers WCDMA

Up to › 40 MHz LTE carriers

› 2x10 Gbps CPRI

12 › kg

› -48 VDC

AISG TMA & RET support›

2 › external alarm

Optional fan for increased site flexibility›

IP › 65, -40 to +55 ̊C

Maximum power consumption for B› 1 <300W

RADIO 2217

Radio dimensionsMounting points Optional FAN

291 mm105 mm

340 mm

Page 7: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 7 (57)

› GSM, WCDMA & LTE

› 2x60 W

› 40 MHz IBW

› Up to 10 Gbps CPRI

› SFP+ supported

› Carrier capacity

– Up to 8 GSM

– Up to 8 WCDMA

– Up to 2x 20 MHz LTE

› 6 external alarms

› Weight : 22 kg

rrus13

Page 8: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 8 (57)

› New modular micro radio system

› Macro feature parity, coordination

› 4 liter and 5 kg installed50%Smaller & lighter

Micro Radio

Page 9: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 9 (57)

105 mm

› 2TX/2RX, 4TX/4RX by use of two 2203

› 2x5W

40 › MHz IBW FDD

Up to › 4 carriers WCDMA

Up to › 40 MHz LTE carriers

› 2x10 Gbps CPRI

› 5kg include bracket and cover

AC or › -48 VDC

Integrated or external antenna›

2 › external alarm

IP › 65

› -40 to + 55 ̊C

Maximum power consumption for B› 1 <100W

RADIO 2203

Single band

Dual band

Rail mount 19 inch mount

Page 10: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 10 (57)

RADIO CORE

SUPPORT SYSTEM

ANTENNA

200 mm

200 mm

Radio dimensions

Total depth with front cover: 100mm

Total depth with high-band antenna: 119mm

Radio 2203

Page 11: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 11 (57)

world’s bestbasebandMade b e t t e r2x

Page 12: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 12 (57)

› 19 inch indoor main unit for baseband

› Mix and match

– Baseband 5212

– Baseband 5216

– Baseband R503

– Baseband T503

– DUW, DUG, DUS & TCU

› Provide the optimal capacity & configuration of GSM,

WCDMA or LTE and combinations thereof

› Dimensions : 483 x 355 x 66 (mm)

› Weight 5.0Kg (<10Kg with DUW)

Baseband Main Unit 6601

2x DUS/BB/IRU

Or 1x DUW

EC Bus X,Y,Z

and SAU

Status

LEDs

Input -48V DCOutput -48V DC

2 units

8x Ext

alarms

Page 13: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 13 (57)

› LTE (FDD & TDD supported)

– 8000 connected users

– 1.2 Gbps Downlink & 600 Mbps Uplink

– Up to 24 cells & 960 MHz antenna bandwidth

› WCDMA

– 1152 CE Downlink & 1920 CE Uplink

– 336 Mbps Downlink & 168 Mbps Uplink

– Up to 24 cell carriers

› GSM

– Up to 24 TRX in a mixed mode configuration

Baseband 5216

Page 14: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 14 (57)

Baseband 5216

RI Port

RRU CPRI Port

GPS Sync Port LMT Port -48 VDC

Input

EC BusRJ-45

TransmissionOptical

Transmission

Inter DU Link

Page 15: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 15 (57)

RRUS13

RBS6601

BB 5216

Macro based

Radio 2217 Radio 2203

RBS6601

BB 5216

Macro based

RBS6601

BB 5216

Micro based

Various configurations

Page 16: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 16 (57)

IPRAN

Bb 5216 connectionsmixed mode WCDMA+LTE

IDL IPRAN

AUX OIL

RI F DC

GPS

U/L2100

SW 16B support.

U/L2100 2x2 MIMO = Max 6 sectors

4X4 MIMO or 2T4R = 3 sectors

Page 17: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 17 (57)

U/L2100 rrus133-6 sectors macro site

New Materials

(3 sectors material list)

1 x MU

2 x BB 5216

3 x RRUS13 + DC Cables

3x OIL 4 Core

2x Patch Cords

U/L2100

Page 18: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 18 (57)

U/L2100 radio 22033-6 sectors micro site

New Materials

(3 sectors material list)

1 x MU

2 x BB 5216

3 x Radio 2203 + DC Cables

3x OIL 4 Core

2x Patch Cords

U/L2100

Page 19: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 19 (57)

U/L2100 radio 22033-6 sectors micro site

New Materials

(3 sectors material list)

1 x MU

2 x BB 5216

3 x Radio 2203 + DC Cables

3x OIL 4 Core

2x Patch Cords

U/L2100

Integrated Antenna option

Page 20: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 20 (57)

L1800 radio 22173-6 sectors macro site

New Materials

(3 sectors material list)

1 x MU

1 x BB 5216

3x Radio 2217 + DC Cables

3x OIL 4 Core

1x Patch Cord

L1800

Page 21: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 21 (57)

L1800 radio 22033-6 sectors micro site

New Materials

(3 sectors material list)

1 x MU

1 x BB 5216

3 x Radio 2203 + DC Cables

3x OIL 4 Core

1x Patch Cords

L1800

Page 22: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 22 (57)

L1800 radio 22033-6 sectors micro site

New Materials

(3 sectors material list)

1 x MU

1 x BB 5216

3 x Radio 2203 + DC Cables

3x OIL 4 Core

1x Patch Cords

L1800

Integrated Antenna option

Page 23: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 23 (57)

RRU13 connections

CPRI

DATA 1

ALD

Antenna Line Device

(RET Connection)

-48 V DC

Input

CPRI

DATA 2

TXA/RXA TXB/RXB

Ground point

Page 24: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 24 (57)

Radio 2217 connections

CPRI

DATA 1

ALD

Antenna Line Device

(RET Connection)

-48 V DC

Input

CPRI

DATA 2

TXA/RXA TXB/RXB

Ground point

LED Status

FAN or

External Alarms

Page 25: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 25 (57)

Install

System

Tower

ownerNew site Antenna Option 1 Antenna Option 2 Remark

U/L2100DTN or

ShareNew build ADU4518R6v01 A19451811 Based on antenna available in stock

U850 DTN New build A79451700v02 -

U850 Share New build ADU451807v01 -

U/L2100 Share Existing U850Reuse ADU451807v02 - In case existing ADU451807

Swap with ADU451807v02 Swap with ADU4518R12

3g 2100 new siteantenna installation options

Page 26: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 26 (57)

DTN 3G 2.1

RRU

Port A

+ Ant

RRU

Port B

- Ant

RRU

Port ARRU

Port B

U/L 2100 overviewAntenna single Band

U/L 2100

AGISSON: A49151811

Page 27: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 27 (57)

E1800

Radio 2217 A RRUS13 A

Radio 2217 B RRUS13 B

DTN 3G 2.1Radio 2217

1800

RRUS13

2100

Radio 2217

1800 to

ports ‘L’

RRUS13

2100 to ports

‘R’

RRUS13

Port A

+ Ant

RRUS13

Port B

- Ant

E 1800 + 3G 2100

U/L 2100 + E 1800 overviewAntenna single Band 4-port

AGISSON: ADU451819

Page 28: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 28 (57)

Radio 2217 A RRUS13 A

Radio 2217 B RRUS13 B

Example setup Example setup

E 1800 + U/L 2100

U/L 2100 + E 1800 overviewAntenna single Band 4-port

AGISSON: ADU4518R6v01

(Integrated RET )

First installed system uses ‘AISG In’

and controls antenna set ‘a’

Page 29: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 29 (57)

TX/RX RX

3G 850

U/L 2100 overviewantenna Dual Band 4 port

RRUS01 A+ RRUS13 A+

RRUS01 B- RRUS13 B-

Filter

850

RF B

-Ant

RF A

Filter

+ Ant

RRUS13

Port A

+ Ant

RRUS13

Port B

- Ant

3G 850 + 3G 2100

AGISSON: ADU451807

3G 850 + E 1800

OR

DTN 3G 2.1

Page 30: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 30 (57)

U/L 2100 overviewantenna Dual Band 4 port

RRUS01 A+ RRUS13 A+

RRUS01 B- RRUS13 B-

3G 850 + 3G 2100

AGISSON: ADU4518R12

(Integrated RET )

3G 850 + E1800

OR

TX/RX RX

3G 850 Filter

850

RF B

-Ant

RF A

Filter

+ Ant

RRUS13

Port A

+ Ant

RRUS13

Port B

- Ant

DTN 3G 2.1

Page 31: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 31 (57)

Overview – tower

DC power

Jumpers

OIL cable DUW

RET/RCU

DC power

Jumpers

OIL cable

RET/RCU

OIL cable DUSRR

US

RR

US

New Clamps 3x2

New OIL cable to be looped

with existing

3G 3G+4G

Page 32: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 32 (57)

SST 35/45m- 3 sectors

DC power

Jumpers

OIL cable

RET/RCU

RR

U

Site breakdown

Rectifier with • aircon door

Installation on frame at tower base•

Tower • 35/45m with 1m ladder spacing

Support up to • 6 antennas (CW check)

• 3x Single antenna mounts

Actual mount to be confirmed after antenna model is •

chosen/CW checks

• 3x RRU behind ant

Rectifier

IPRAN

DU/BB 5216

Single band antennas

Add single mount & RRU/antenna

Page 33: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 33 (57)

Radio 2217 mounting scenarios

Rad

io

22

17

Page 34: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 34 (57)

Pole 9m –Example - single sector

DC power

Jumpers

OIL cable

RET/RCU

RR

U

Rectifier

IPRAN

DU/BB 5216

Site breakdown

• Centrally located rectifier with aircon door

• Installation on H-Beam

• Horizontal ladder is site specific

• Standard 400mm where possible

• 9m Pole with 1m ladder spacing

• Support up to 6 antennas

• Single or twin antenna mounts

• Depend on configuration, 1/2/3 cells

• Actual mount to be confirmed after antenna model is

chosen/CW checks

• RRU behind antenna

Page 35: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 35 (57)

Ra

dio

2203

Ra

dio

2203

E-pole 12m - 3 sectors

DC power

Jumpers

OIL cable

RET/RCU

Site breakdown

Rectifier optional or PBS•

RBS• 6320 installed directly on E-pole

12• m E-Pole with 1m ladder spacing

Support up to • 3 antennas (CW check)

• 2x twin antenna mounts

Actual mount to be confirmed after antenna model is •

chosen/CW checks

• 3x RRU behind antenna or new radio on single 2m pole

R

R

U

R

R

U

R

R

U

3x Rail mounted

Radios 2203

E-Pole Micro cell

Ra

dio

2203

RBS6320 installed with

Baseband and IPRAN

Page 36: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Radio 2203mounting andinstallation

Page 37: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 37 (57)

Radio 2203

Page 38: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 38 (57)

Rail Mounting options

Page 39: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 39 (57)

Rail installation

Fasten the mounting bracket to the

Support by tightening the bolts.

Hook the Support onto the

upper part of the rail.

Push the lower part of the

Support against the lower part

of the rail.

Page 40: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 40 (57)

Rail installation

Fit the bolt in the rail groove. Tighten the bolt to fasten the

Support to the rail. Make sure

that the Support is firmly attached

to the rail.

Page 41: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Radio 2217 mounting andinstallation

Page 42: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 42 (57)

Rail Mounting optionsSide Wall installation Flat Pole installation

Pole installation with single pole clamp

Flat Wall installation Side Pole installation

Dual pole clamp

Page 43: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 43 (57)

Rail descriptionRail Product code

Dimensions

(H×D×L) (mm)

Rail

Weight

Maximum

Radio support

SEF901305/0180 208×45×180 1.42 kg 1

SEF901305/0300208 ×45×300 2.36 kg

3 Radio or

2 Radio/fan

SEF901305/0450 208×45×450 3.54 kg4 Radio or

3 Radio/fan

SEF901305/1100 208×45×1100 8.65 kg

9 Radio or

8 Radio/fan

(Dual Pole mount is

required)

SXK1252540/1 138×187×197 2.4 Pole clamp

Page 44: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 44 (57)

Bracket Mounting positions

Position 1Position 2

8mm x 20mm

Hex screws (qty 4)

1. If required remove the plugs in the radio mounting holes. Fit the

retaining bolt loosely to the bottom of the bracket.

2. Orientate the bracket with the retaining bolt on the bottom and

secure to the radio as required using the 4 8mm mounting bolts

supplied.

3. Torque the four bracket bolts to 22 Nm with the 13mm socket on

the torque wrench.

Radio Rail Bracket : SEF901304/1

Radio rail bracket 13mm. bolts

Slot for

lateral

adjust

Retaining Bolt/nut. Leave

loose to engage rail slot.W x H x L : 70 x 35 x 200

Page 45: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 45 (57)

Attaching The Radio to railHook the top flange on the radio bracket onto the rail

upper flange and swing down so it is flush on the rail

and the retaining bolt engages into the rail slot. Slide

the radio to adjust spacing with adjacent radios as

required (min 7mm no fan or no space with fan.

Tighten the retaining bolt with a deep

13mm socket to allow the nut to sit in the

slot on the radio bracket. Torque the radio

bracket bolt to 22 Nm.

Page 46: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 46 (57)

Install Rail on Wall

1. Mark the positions of the mounting

holes using the footprint of the rail as

a drill template.

2. Drill mounting holes in the wall.

Page 47: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 47 (57)

Install Rail on Wall

3. Insert plugs or an expander bolt into the

hole. (Plugs or expander bolts are not

delivered with the unit)

4. Position the rail over the holes and

fasten with screws using the appropriate

torque. Make sure that the bolts are

securely fastened.

Page 48: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 48 (57)

Mounting on tower/ polesingle bracket

Page 49: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 49 (57)

Single Pole Clamp Installation

1. Assemble the pole clamp 2. Install the rail on the pole clamp. 3. Tighten the nuts.

Page 50: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 50 (57)

Single Pole Clamp Installation

4. Install the pole clamp on the pole 5. Tighten the nut on pole clamp

Page 51: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 51 (57)

Single Pole Clamp Installation

1

2

Page 52: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 52 (57)

Single Pole Clamp Installation

3 4

Page 53: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 53 (57)

Install Radio SFP Modules

1. Remove the protective cap from the optical

cable 1 connector on the Remote Radio Unit.

2. Important: Verify with material or site records

that the SFP is the correct type and part

number. Contact support for help if required.

3. Insert an SFP module with the latch opened into

the SFP receptacle on the Radio connector then

lock in place by raising the latch.

4. Replace the protective weather cap for hoisting

or if cable is not ready.

5. Repeat this procedure for each Remote Radio

as required.

Page 54: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 54 (57)

New Jumper connections

• 4.3-10 Key features

• Excellent RL and PIM performances independently from

the torque applied or mechanism used

• High screening efficiency

• Electrical contact protected against accidental hits

• Compactness: the connector is fitting in 1 inch flange

(25.4 mm)

• Low weight (60% lighter compared to bigger RF

interfaces)

• 3 possible mechanical connections (screw, hand screw

and quick lock) on 1 universal female connector

• IEC standardization

Page 55: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 55 (57)

Radio 2217 fan moduleFan used when installing in non-vertical installation

Fan module

installed

Page 56: New baseband And radio system1com.com...› 2 external alarm › Optional fan for increased site flexibility › IP 65, -40 to +55 C › Maximum power consumption for B1

Ericsson Internal | 2016-08-23 | Page 56 (57)

Installing Fan units

1. If required remove the plugs in the radio mounting

holes.

2. Secure the Fan to the side cover. (Alternately the fan

can be installed after the cover)..

3. Orientate the fan unit as shown and slide into place

over the cooling fins of the radio.

4. Secure with the 4 retaining screws and Torque the four

screws to 6 Nm with the Torx 20 driver.

5. Plug the fan cable into the Fan connector on the radio

FAN Connector