1 Never miss capturing a disturbance Testing power quality in backup power systems

description

Never miss capturing a disturbance. Testing power quality in backup power systems. Our automated world. Data centers, banks, hospitals, industrial sites and other facilities all rely on electrical power Many have mission-critical systems/processes Inter-related systems add more complexity - PowerPoint PPT Presentation

Transcript of Never miss capturing a disturbance

Page 1: Never miss capturing a disturbance

1

Never miss capturinga disturbance

Testing power quality inbackup power systems

Page 2: Never miss capturing a disturbance

2

Our automated world

• Data centers, banks, hospitals, industrial sites and other facilities all rely on electrical power

• Many have mission-critical systems/processes

• Inter-related systems add more complexity

• The 24/7 economy demands ‘always-on’ so…

• Growing dependence on UPS systems & diesel-powered emergency generators

Page 3: Never miss capturing a disturbance

3

The hidden challenge

Even with regular testing of your backup systems:•Undetected power quality problems elsewhere in the facility can still cause backup systems to malfunction

•Leading to higher energy costs…

•…or catastrophic failure – and downtime!

Page 4: Never miss capturing a disturbance

4

The power quality challenges

Spikes, transients, harmonics and frequency deviations: often invisible and unpredictable •How do you know what you’re up against?

•Then capture it and measure it?

•Accurately, and in sufficient resolution?

•And be sure you’ve not missed an event?

Answer: Use long-term recording and analysis…

Page 5: Never miss capturing a disturbance

5

Introducing the Fluke 1750

The three-phase power recorder that reveals the true state of your electrical distribution system

Page 6: Never miss capturing a disturbance

6

Power quality testing is easy

• Worry-free setupautomatic threshold-free measurement system

• Never miss a disturbancecapture every event, on every cycle, all the time (30 day standard memory)

• Understand test outcomes easilyintuitive software for analysis and reporting

• Simplify compliance checksall the latest power quality standards are built-in

Page 7: Never miss capturing a disturbance

7

Now with enhanced features

Auto Reportgenerate template-based reports in seconds or customized reports in minutes

User definable summary limitsuser definition for summary reporting according to IEEE or IEC limits

Enhanced graphicsauto/manual scaling; relative and absolute cursor measurements; improved data zoom