Networking Chapter 6

120
Installing a Physical Network Chapter 6

description

 

Transcript of Networking Chapter 6

Page 1: Networking Chapter 6

Installing a Physical NetworkInstalling a Physical Network

Chapter 6

Page 2: Networking Chapter 6

ObjectivesObjectives• Recognize and describe the functions of basic

components in a structured cabling system• Explain the process of installing structured

cable• Install a network interface card• Perform basic troubleshooting on a

structured cable network

Page 3: Networking Chapter 6

OverviewOverview

Page 4: Networking Chapter 6

Figure 6.1 What an orderly looking network!

Page 5: Networking Chapter 6

Figure 6.2 A real-world network

Page 6: Networking Chapter 6

Four Parts to Chapter 6Four Parts to Chapter 6

• Understanding Structured Cabling• Installing Structured Cabling• NICs• Diagnostics and Repair of Physical Cabling

Page 7: Networking Chapter 6

Understanding Understanding Structured CablingStructured Cabling

Page 8: Networking Chapter 6

• Set of TIA/EIA standards• Details on every aspect of cabled network

– Type of cabling– Position of wall outlets– And more…

Page 9: Networking Chapter 6

• Goal – Create a safe, reliable cabling infrastructure

• Applies to– Networks– Telephone– Video– Anything that needs low-power, distributed

cabling

Page 10: Networking Chapter 6

• Three important issues – Cable basics– Network Components

– Assessment of connections leading outside the network

Page 11: Networking Chapter 6

• Cable Basics – A Star is Born– Most basic network

• A switch• UTP cable• Some PCs

Page 12: Networking Chapter 6

Figure 6.3 A switch connected by UTP cable to two PCs

Page 13: Networking Chapter 6

• Problems in keeping it simple (a switch in middle of office space)– Exposed cables are vulnerable to physical

damage– Signals exposed to electrical interference– Limits ability to make changes to network

Page 14: Networking Chapter 6

• Better installation design– Provides safety– Provides hardware to organize and protect

cabling• Flexibility of cabling standard allows for growth

• Solution: TIA/EIA standards for structured cabling

Page 15: Networking Chapter 6

• Structured Cable Network Components– Telecommunications room– Horizontal cabling– Work area

Page 16: Networking Chapter 6

Figure 6.4 Telecommunications room

Page 17: Networking Chapter 6

• Horizontal cabling– From work area to telecommunications

room– CAT5e or better– Solid core

• Better conductor than stranded core• Will break if mishandled

– Stranded core• Not as good a conductor• Stands up to handling without breaking

Page 18: Networking Chapter 6

Figure 6.5 Horizontal cabling and work area

Page 19: Networking Chapter 6

Figure 6.6 Solid and stranded core UTP

Page 20: Networking Chapter 6

• Horizontal cabling – Number of Strands– Four-pair UTP assumed– High-end telephone setups

use 25- or 100-pair

Page 21: Networking Chapter 6

• Choosing Your Horizontal Cabling– CAT 5e or CAT 6 UTP– CAT 6a for 10GBaseT– Install higher-rated cable for future

technologies– Contract network installers will bid with

intention of installing lowest grade possible

Page 22: Networking Chapter 6

• The Telecommunications Room– Heart of basic star– Intermediate distribution frame (IDF)– Endpoint of all horizontal runs from all

work areas– Central component is equipment rack

Page 23: Networking Chapter 6

• Equipment Rack– Safe, stable platform for hardware components– Network equipment comes rack-mounted– 19 inches wide – Varies in height

• U = 1.75”• 1U, 2U, 4U

Page 24: Networking Chapter 6

Figure 6.8 A short equipment rack

Page 25: Networking Chapter 6

Figure 6.9 A floor-to-ceiling rack

Page 26: Networking Chapter 6

• Patch Panel box– Row of female connectors (ports) in front– Permanent connections to horizontal cables in

back• 110-punchdown block• Connect cables with punchdown tool

Page 27: Networking Chapter 6

Figure 6.10 A rack-mounted UPS

Page 28: Networking Chapter 6

Figure 6.11 Typical patch panels

Page 29: Networking Chapter 6

Figure 6.12 Punchdown tool

Page 30: Networking Chapter 6

Figure 6.13 Punching down a 110 block

Page 31: Networking Chapter 6

Figure 6.14 66-block patch panels

Page 32: Networking Chapter 6

• Patch Panel box (continued)– Label cable connections on panel

• Use a simple labeling scheme• TIA/EIA 606 is confusing

– Wide variety of configurations• UTP, STP, or fiber ports• 8, 12, 24, 48, or more ports• UTP patch panels come with UTP ratings

Page 33: Networking Chapter 6

Figure 6.15 Typical patch panels

Page 34: Networking Chapter 6

Figure 6.16 CAT level on patch panel

Page 35: Networking Chapter 6

• Cables– Connect patch cables to ports on front of panel

• Short (two to five feet)• Premade UTP offer benefits

– Stranded rather than solid cable – Different colors to help organize– Reinforced (booted) connector

Page 36: Networking Chapter 6

Figure 6.17 Typical patch cable

Page 37: Networking Chapter 6

Figure 6.18 Network taking shape

Patch Panel box

Page 38: Networking Chapter 6

• Work Area– Wall outlet

• Female jack with CAT rating to accept cabling• Mounting plate, and faceplate

– Connect PC to wall outlet with patch cable– Work area is source of most network failures

Page 39: Networking Chapter 6

Figure 6.19 Typical work area outlet

Page 40: Networking Chapter 6

Figure 6.20 Properly labeled outlet

Page 41: Networking Chapter 6

• Structured Cable – Beyond the Star– Cabling on one floor a single star topology– Cabling an entire building more complex– Most LANs connect to both Internet & telephone

company

Page 42: Networking Chapter 6

Figure 6.21 25-pair running to local 66-block

Page 43: Networking Chapter 6

Figure 6.22 Typical home network interface box

Page 44: Networking Chapter 6

• Structured Cable – Beyond the Star (cont.)– Typical building-wide network

• High-speed backbone runs vertically• Backbone connects to multispeed switch on each floor• Dedicated telephone cabling backbone runs alongside• Demarc (demarcation point)

Page 45: Networking Chapter 6

• More on Demarcs– Connection to outside world– Dividing line of responsibility– Network interface unit (NIU)

• DSL or cable modem serves as a demarc in a home• Smart jack in NIU enables remote testing

Page 46: Networking Chapter 6

Figure 6.23 Typical office demarc

Page 47: Networking Chapter 6

Figure 6.24 LAN vertical cross-connect

Page 48: Networking Chapter 6

Figure 6.25 Telephone vertical cross-connect

Page 49: Networking Chapter 6

• Structured Cable – Beyond the Star (cont.)– Connections inside the demarc

• Network and telephone cables connect to demarc extension

– Multiplexer for telephones– LAN switch for a network

» Connects to a main patch panel—a vertical cross-connect

Page 50: Networking Chapter 6

• Structured Cable – Beyond the Star (cont.)– Main distribution frame (MDF)

• Another name for telecommunications room

Page 51: Networking Chapter 6

Installing Structured Installing Structured CablingCabling

Page 52: Networking Chapter 6

• Getting a Floor Plan– Key to proper planning– Determine potential locations for

telecommunications rooms– Locate physical firewalls– Gives an overall feel for scope of job– If no floor plan, create one

Page 53: Networking Chapter 6

Figure 6.26 Hand-drawn network floor plan

Page 54: Networking Chapter 6

• Mapping the Runs– Determine the length of cable runs– Determine the route of cable runs– Determine location of each cable drop

Page 55: Networking Chapter 6

• Mapping the Runs (cont.)– Talk to users, management, etc.

• Determine future plans• Add extra drops

– Begin to determine cost– Decide if cable runs will be inside or outside wall

• Raceways install outside walls

Page 56: Networking Chapter 6

Figure 6.27 A typical raceway

Page 57: Networking Chapter 6

• Determining Location of Telecommunications Room– Distance no more than 90 meters from drops– Power requirements of equipment– Humidity– Cooling– Expandability

Page 58: Networking Chapter 6

Figure 6.28 An A/C duct cooling a telecommunications room

Page 59: Networking Chapter 6

• Pulling Cable– Requires two to three people– Start in telecommunications room and pull to

drops– Open drop ceiling and string via hooks or cable

trays– Have correct tools

Page 60: Networking Chapter 6

Figure 6.29 Cable trays over a drop ceiling

Page 61: Networking Chapter 6

• Pulling Cable (cont.)– Good cable management important for

fast networks– Follow local codes, TIA/EIA, and NEC– Vertical drops most difficult– Install a low-voltage mounting bracket to

hold faceplate – Use cable guides to help organize

equipment closet

Page 62: Networking Chapter 6

Figure 6.30 Messy cabling nightmare

Page 63: Networking Chapter 6

Figure 6.31 Nicely run cables (image is vertical in the book)

Page 64: Networking Chapter 6

• Making Connections– Connecting the work areas

• Crimp wall jack to wire• Mount faceplate• Fit jack into faceplate

Page 65: Networking Chapter 6

Figure 6.32 Cutting a hole

Page 66: Networking Chapter 6

Figure 6.33 Locating a dropped pull rope

Page 67: Networking Chapter 6

Figure 6.34 Installing a mounting bracket

Page 68: Networking Chapter 6

Figure 6.35 End of cables guided to rack

Page 69: Networking Chapter 6

• Rolling Your Own Patch Cables– Use stranded UTP cable matching CAT level

of horizontal runs– Use special crimp for stranded cable

• RJ-45 crimper with built-in stripper• Pair of wire snips• Follow great instructions on Page 114 in Chapter 6

Page 70: Networking Chapter 6

Figure 6.36 Crimping a jack

Page 71: Networking Chapter 6

Figure 6.37 Crimper and snips

Page 72: Networking Chapter 6

Figure 6.38 Properly stripped cable

Page 73: Networking Chapter 6

Figure 6.39 Inserting the individual strands

Page 74: Networking Chapter 6

Figure 6.40 Crimping the cable

Page 75: Networking Chapter 6

Figure 6.41 Properly crimped cable

Page 76: Networking Chapter 6

Figure 6.42 Adding a boot

Page 77: Networking Chapter 6

• Connecting the Patch Panels– Incorporate good cable management– Plastic D-rings– Finger boxes– Organize to mirror the layout of network

Page 78: Networking Chapter 6

Figure 6.43 Bad cable management

Page 79: Networking Chapter 6

Figure 6.44 Good cable management

Page 80: Networking Chapter 6

• Test the Cable Runs– Verify each cable run can handle network speed– Advanced network testing tools are $5,000-

$10,000– Lower-end tools work for basic network testing

• Length of cable• Broken wires• Location of break• Wires terminated in correct place• Locate electrical or radio interference• Test for crosstalk

Page 81: Networking Chapter 6

• Tools to use– Cable tester

• Verifies cable and terminated ends are correct• Low-end are continuity testers• Better testers run wire map test to pick up shorts,

crossed wires, etc.• Multimeter tests continuity

Page 82: Networking Chapter 6

Figure 6.45 Continuity tester

Page 83: Networking Chapter 6

Figure 6.46 Multimeter

Page 84: Networking Chapter 6

Figure 6.51 A typical cable certifier – a Microtest OMNIScanner (photo courtesy of Fluke Networks)

Page 85: Networking Chapter 6

• Testing Fiber– Termination process is more involved

• Stripping, polishing end of tiny fiber cable, gluing, inserting connector

• Requires lots of tools and skill– Problems both like and unlike those of

UTP cabling• Fiber does not experience crosstalk• Fiber does break – test with optical time domain

reflectometer (OTDR)

Page 86: Networking Chapter 6

Figure 6.52 Older fiber termination kit

Page 87: Networking Chapter 6

• Testing Fiber (cont.)– TIA/EIA has complex requirements for testing

fiber runs– Fiber certifiers test for

• Attenuation – diffusion of light distance• Light leakage – occurs when fiber is bent

too much• Modal distortion – unique to multimode

fiber-optic cable

Page 88: Networking Chapter 6

Figure 6.53 An optical time domain reflectometer (photo courtesy of Fluke Networks)

Page 89: Networking Chapter 6

Figure 6.54 Light leakage – note the colored glow at the bends but the dark cable at the straight

Page 90: Networking Chapter 6

NICsNICs

Teaching TipSummarize the section on Installing Structured Cabling by using the last paragraph on Page 121. This chapter does not prepare students for the highly skilled tasks required for installing structured cabling themselves. Rather, helps them gain an understanding of the process of installing structured cabling in order to work with most problems that come up in an installed structured cabling system.Teaching TipSummarize the section on Installing Structured Cabling by using the last paragraph on Page 121. This chapter does not prepare students for the highly skilled tasks required for installing structured cabling themselves. Rather, helps them gain an understanding of the process of installing structured cabling in order to work with most problems that come up in an installed structured cabling system.

Page 91: Networking Chapter 6

• Recognize different types of NICs on sight• Know how to install and troubleshoot NICs

Page 92: Networking Chapter 6

• UTP Ethernet NICs– All use RJ-45 connector– Cable runs from NIC to hub or switch

Page 93: Networking Chapter 6

Figure 6.55 Typical UTP NIC

Page 94: Networking Chapter 6

• Fiber-optic NICs– Come in a wide variety– Multiple standards use same connector types– Must see documentation to determine what

standard card supports

Page 95: Networking Chapter 6

• Buying NICs– Recommend name-brand NICS

• 3Com or Intel– Better made– Easy to replace missing driver

– Recommend multispeed NICs– Stick with same model for all systems

Page 96: Networking Chapter 6

• Physical Connections– Physically install the NIC– Many computers have built-in NICs

Page 97: Networking Chapter 6

• Physical Connections (cont.)– Expansion Slots

• Peripheral Component Interconnect (PCI)• PCI Express (PCIe) – PCIe x1 and PCIe x2• USB

– Convenient– Limited to max speed of 480 Mbps

– Carry one in toolkit to test for failed NIC • PC Card only on laptops

Page 98: Networking Chapter 6

• Drivers– Insert driver CD when prompted– OS may have a driver, but CD has extras– Verify driver install

• Windows Device Manager• Linux Administration menu Network applet• Macintosh System Preferences Network utility

Page 99: Networking Chapter 6

Figure 6.56 Typical fiber NIC (photo courtesy of 3Com Corp.)

Page 100: Networking Chapter 6

Figure 6.57 PCI NIC

Page 101: Networking Chapter 6

Figure 6.58 PCIe NIC

Page 102: Networking Chapter 6

Figure 6.59 USB NIC

Page 103: Networking Chapter 6

• Link Lights– UTP NICs have LEDs for state of link– One to four link lights per card– Lights give clues about what’s happening– Check link lights when troubleshooting– Many fiber-optic NICs don’t have lights

Page 104: Networking Chapter 6

Figure 6.60 Mmmm, pretty lights!

Page 105: Networking Chapter 6

Figure 6.61 Multispeed lights

Page 106: Networking Chapter 6

Figure 6.62 Link lights on a switch

Page 107: Networking Chapter 6

Figure 6.63 Optical connection tester

Page 108: Networking Chapter 6

Diagnostics and Repair Diagnostics and Repair of Physical Cablingof Physical Cabling

Page 109: Networking Chapter 6

• Diagnostics and Repair of Physical Cabling– Diagnosing Physical Problems (in order)

• Remove software network issues– If one application fails, try another

• Resolve hardware issues– “No server is found” error– No computers visible in Network app in Windows– Multiple systems failing to access the network

Page 110: Networking Chapter 6

• Diagnostics and Repair of Physical Cabling– Check your lights (if available)– Check the NIC itself– Look for network status icon in the Notification

Area in Windows– Check for failed switch

Page 111: Networking Chapter 6

Figure 6.64 Disconnected NIC in Vista

Page 112: Networking Chapter 6

• Diagnostics and Repair of Physical Cabling– Check shared resources (servers)– Visually check cabling– Plug system into a known good outlet

• If this works, suspect structured cabling running from drop to switch• Confirm with continuity test

Page 113: Networking Chapter 6

• Diagnostics and Repair of Physical Cabling– Check the NIC

• Detect bad NIC with operating system utility• Use available NIC diagnostic software• Loopback test on NIC

– Internal only checks circuitry– External (with loopback plug) tests connector

Page 114: Networking Chapter 6

Figure 6.65 Loopback plug

Page 115: Networking Chapter 6

Figure 6.66 Loopback plug in action

Page 116: Networking Chapter 6

• Diagnostics and Repair of Physical Cabling– Cable Testing

• Most problems occur at the work area• After eliminating work area problems, go deeper• Use a time domain reflectometer (TDR)• Check problems in telecommunications room

– Start at one end, placing stickers to track progress– Power concerns– Temperature concerns

Page 117: Networking Chapter 6

Figure 6.67 An excellent voltage event recorder (photo courtesy of Fluke Networks)

Page 118: Networking Chapter 6

• Diagnostics and Repair of Physical Cabling– Cable Testing

• Toners– Trace cable runs– Two separate devices

» Tone generator» Tone probe

– Fox and Hound by Triplett Corporation– Advanced toners include phone jacks for communication

Page 119: Networking Chapter 6

Figure 6.68 Fox and Hound

Page 120: Networking Chapter 6

Figure 6.69 Technician with a butt set