NDT Films Guide 12009

1
KODAK INDUSTREX Films for Industrial X-Ray Use — Product Guide INDUSTREX, LANEX, LEAD PACK, and READY-PACK II are trademarks of Carestream Health, Inc. Revised 1-09 The Kodak trademark and trade dress are used under license from Kodak. www.carestreamhealth.com Exclusive manufacturer of Industrex Products * AMERICAS: KODAK INDUSTREX Single Part Developer Replenisher to make 38L, CAT No. 104 3017; KODAK INDUSTREX Single Part Developer Starter to make 19L, CAT No. 835 1413; KODAK INDUSTREX LO Fixer and Replenisher to make 38L, CAT No. 163 4559. GREATER ASIA: KODAK INDUSTREX Single Part Developer Replenisher to make 38L, CAT No. 662 0025; KODAK INDUSTREX Single Part Developer Starter to make 19L, CAT No. 835 1413; KODAK INDUSTREX LO Fixer and Replenisher to make 38L CAT No. 662 0033. EUROPE, AFRICA, MIDDLE EAST & RUSSIA: KODAK INDUSTREX Single Part Developer Replenisher to make 20L, CAT No. 515 5924; KODAK INDUSTREX Single Part Developer Starter to make 19L, CAT No. 835 1413; KODAK INDUSTREX LO Fixer and Replenisher to make 20L, CAT No. 515 9082. Classification applies to KODAK films, not the other manufacturer’s product they are replacing. KODAK LED Safelight (red): E27 European base 230vac CAT No. 829 3136; E26 North American base 115vac, CAT No. 852 6444. § For optimum archivability, such as required for nuclear applications, a 10% increase in fixer replenishment rate may be desirable. For more information, consult the Guide to Manual Processing of NDT Films, TI-2643, and/or Processing KODAK INDUSTREX Films, TI-2621. ** HS800 displays high speed and contrast throughout an extended range of optical densities when used with fluorescent and fluorometallic screens. HS800 is recommended for use with KODAK LANEX Fast Screens, CAT No. 116 0688. KODAK INDUSTREX Film / Product Code Classification† Notched Replaces† Available Formats (code) Spectral Sensitivity Safelight Filter Processing Chemicals* Developer Fixer Recommended Starting Points Reference Publication on Web Sheets Rolls EN 584 ASTM E1815 ISO 11699 Agfa Fuji Non-Interleaved (1) READY-PACK II (2) Pb Contactpak (7) NIF Rolls (bulk) (359) LEAD PACK (382) Ready Pack (381) DR50 / 6536 C1 Special T1 D2 IX25 X-ray and visible blue light (Red) 660 nm LED , 1, 1A, or GBX-2 DEVELOPER KODAK INDUSTREX Single Part Developer Replenisher, mixed 1:3 w/H 2 O Replenishment Rate: 665mL/m 2 FIXER KODAK INDUSTREX LO Fixer and Replenisher, mixed 1:4 w/ H 2 O (Americas & Greater Asia), or KODAK INDUSTREX LO Fixer and Replenisher, mixed 1:3 w/ H 2 O (Europe, Africa, Middle East & Russia) Replenishment Rate: § 1200mL/m 2 AUTOMATIC 8 minute cycle Development Time and Temperature: 100 seconds @ 26°C (79°F) 5 minute cycle Development Time and Temperature: 60 seconds @ 30°C (86°F) MANUAL Development Time and Temperature: 5 minutes @ 20°C (68°F) TI2508 M100 / 5532 C2 Class I T1 D3 IX50 TI2434 MX125 / 4748 C3 Class I T2 D4 IX50 TI2342 T200 / 6537 C4 Class I T2 D5 IX80 TI2360 AA400 / 5533 C5 Class II T3 D7 IX100 TI2294 HS800** / 5747 D8/F8 IX150 TI2637

Transcript of NDT Films Guide 12009

Page 1: NDT Films Guide 12009

KODAK INDUSTREX Films for Industrial X-Ray Use — Product Guide

INDUSTREX, LANEX, LEAD PACK, and READY-PACK II are trademarks of Carestream Health, Inc. Revised 1-09 The Kodak trademark and trade dress are used under license from Kodak.

www.carestreamhealth.com Exclusive manufacturer of Industrex Products

* AMERICAS: KODAK INDUSTREX Single Part Developer Replenisher to make 38L, CAT No. 104 3017; KODAK INDUSTREX Single Part Developer Starter to make 19L, CAT No. 835 1413; KODAK INDUSTREX LO Fixer and Replenisher to make 38L, CAT No. 163 4559. GREATER ASIA: KODAK INDUSTREX Single Part Developer Replenisher to make 38L, CAT No. 662 0025; KODAK INDUSTREX Single Part Developer Starter to make 19L, CAT No. 835 1413; KODAK INDUSTREX LO Fixer and Replenisher to make 38L CAT No. 662 0033. EUROPE, AFRICA, MIDDLE EAST & RUSSIA: KODAK INDUSTREX Single Part Developer Replenisher to make 20L, CAT No. 515 5924; KODAK INDUSTREX Single Part Developer Starter to make 19L, CAT No. 835 1413; KODAK INDUSTREX LO Fixer and Replenisher to make 20L, CAT No. 515 9082.

† Classification applies to KODAK films, not the other manufacturer’s product they are replacing.

‡ KODAK LED Safelight (red): E27 European base 230vac CAT No. 829 3136; E26 North American base 115vac, CAT No. 852 6444.

§ For optimum archivability, such as required for nuclear applications, a 10% increase in fixer replenishment rate may be desirable. For more information, consult the Guide to Manual Processing of NDT Films, TI-2643, and/or Processing KODAK INDUSTREX Films, TI-2621.

** HS800 displays high speed and contrast throughout an extended range of optical densities when used with fluorescent and fluorometallic screens. HS800 is recommended for use with KODAK LANEX Fast Screens, CAT No. 116 0688.

KODAK INDUSTREX

Film / Product Code

Classification†

Not

ched

Replaces†Available Formats (code)

Spectral Sensitivity

Safelight Filter

Processing Chemicals*Developer

—Fixer

Recommended Starting Points

Ref

eren

cePu

blic

atio

n on

WebSheets Rolls

EN 5

84

AST

M E

1815

ISO

116

99

Agf

a

Fuji

Non

-Inte

rleav

ed

(1)

REA

DY-

PAC

K II

(2

)

Pb C

onta

ctpa

k(7

)

NIF

Rol

ls (b

ulk)

(3

59)

LEA

D P

AC

K

(382

)

Rea

dy P

ack

(381

)

DR50 / 6536 C1 Special T1 ✔ D

2

IX25 ✔

X-ray and

visible blue

light

(Red)

660 nm

LED‡,

1, 1A, or

GBX-2

DEVELOPERKODAK INDUSTREX Single Part Developer Replenisher,

mixed 1:3 w/H2OReplenishment Rate:

665mL/m2

—FIXER

KODAK INDUSTREX LO Fixer and Replenisher, mixed 1:4 w/

H2O (Americas & Greater Asia), or

KODAK INDUSTREX LO Fixer and Replenisher, mixed 1:3 w/H2O (Europe, Africa, Middle

East & Russia)

Replenishment Rate: §

1200mL/m2

AUTOMATIC8 minute cycle

Development Time and Temperature:

100 seconds @ 26°C (79°F)

— 5 minute cycle

Development Time and Temperature:

60 seconds @ 30°C (86°F)

—MANUAL

Development Time and Temperature: 5 minutes @ 20°C

(68°F)

TI2508

M100 / 5532 C2 Class I T1 ✔ D

3

IX50 ✔ ✔ ✔ ✔ ✔ ✔ TI2434

MX125 / 4748 C3 Class I T2 D

4

IX50 ✔ ✔ ✔ ✔ ✔ ✔ TI2342

T200 / 6537 C4 Class I T2 ✔ D

5

IX80 ✔ ✔ ✔ TI2360

AA400 / 5533 C5 Class II T3 ✔ D

7

IX10

0

✔ ✔ ✔ ✔ ✔ ✔ TI2294

HS800** / 5747 — — — ✔

D8/

F8

IX15

0

✔ ✔ ✔ TI2637