Agenda
- Where are the costs in a data centre?
- How do we measure them?
- 5 steps to reduce your power bills in a data centre
- Conclusion
![Page 3: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/3.jpg)
Background & Biases
- 12 years IT experience in solution sales, consulting implementation, operations & support
- Last 4 years in data centre design, built and operate. - Setup with first Tier IV (Design) certified data centre in
Mauritius - Launch of first 100% Microsoft technologies stack
based public cloud service - Bhumishq provides data centre hosting and Cloud
solutions
![Page 4: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/4.jpg)
Data Centre Cost Breakdown
![Page 5: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/5.jpg)
Measuring Data Centre Efficiency
A. Power Usage Effectiveness (PUE)
B. Data Centre Infrastructure Efficiency (DCiE)
![Page 6: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/6.jpg)
Measuring Data Centre Efficiency
A. Power Usage Effectiveness (PUE)
PUE = Total Facility Power / IT Equipment Power
– PUE is a ratio
– Closer to 1, the better
Example -
PUE = 200 kW / 110 kW
PUE = 1.81
![Page 7: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/7.jpg)
Measuring Data Centre Efficiency
![Page 8: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/8.jpg)
Measuring Data Centre Efficiency
A. Power Usage Effectiveness (PUE) B. Data Centre Infrastructure Efficiency (DCiE) DCiE = (IT equipment power) / (Total facility power) x 100 - DCiE is a percentage - Closer to 100%, the better Example – DCiE = 110 kW / 200 kW x 100 DCiE = 55%
![Page 9: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/9.jpg)
Measuring Data Centre Efficiency
![Page 10: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/10.jpg)
Measuring Data Centre Efficiency
A. Power Usage Effectiveness (PUE)
B. Data Centre Infrastructure Efficiency (DCiE)
![Page 11: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/11.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
![Page 12: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/12.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
2. Use high efficiency UPS
Example - A 90% efficient UPS load will be using 90 kW while demanding 100 kW. This means 10 kW is lost energy or 87,600 kWh of lost energy per year. At utility rate of Rs. 6/kWh, this means annual loss of Rs. 525,600. Plus extras cooling cost which is 33% of lost kW.
![Page 13: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/13.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
2. Use high efficiency UPS
3. Use cooling best practices
Key Areas
a. Hot aisle / cold aisle
![Page 14: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/14.jpg)
5 Steps To Reduce Your Power Bills
Hot aisle / Cold aisle
![Page 15: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/15.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
2. Use high efficiency UPS
3. Use cooling best practices
Key Areas
a. Hot aisle / cold aisle
b. Use blanking panels
![Page 16: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/16.jpg)
5 Steps To Reduce Your Power Bills
![Page 17: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/17.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
2. Use high efficiency UPS
3. Use cooling best practices
Key Areas
a. Hot aisle / cold aisle
b. Use blanking panels
c. Sealing gaps in server room
![Page 18: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/18.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
2. Use high efficiency UPS
3. Use cooling best practices
Key Areas
a. Hot aisle / cold aisle
b. Use blanking panels
c. Sealing gaps in server room
d. Raise server room temperature
![Page 19: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/19.jpg)
5 Steps To Reduce Your Power Bills
![Page 20: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/20.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
2. Use high efficiency UPS
3. Use cooling best practices
Key Areas
a. Hot aisle / cold aisle
b. Use blanking panels
c. Sealing gaps in server room
d. Raise server room temperature
e. Using high-density supplemental cooling
![Page 21: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/21.jpg)
5 Steps To Reduce Your Power Bills
![Page 22: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/22.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
2. Use high efficiency UPS
3. Use cooling best practices
4. Power management feature
![Page 23: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/23.jpg)
5 Steps To Reduce Your Power Bills
1. Virtualization
2. Use high efficiency UPS
3. Use cooling best practices
4. Power management feature
5. Monitor consumption
![Page 24: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/24.jpg)
![Page 25: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/25.jpg)
![Page 26: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/26.jpg)
![Page 27: NCB Green IT Workshop 23Jul2012 (Reducing Power bills in your data centre )](https://reader030.fdocuments.us/reader030/viewer/2022032617/55aa75f71a28ab720d8b45fe/html5/thumbnails/27.jpg)
Questions?