Page 1: NAVB 410 NAMIC DreamKit Rev1b - Kimal · The NAMIC “Dream Kit” How the Compensator Manifold Works: Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more

Dream Kit

Page 2: NAVB 410 NAMIC DreamKit Rev1b - Kimal · The NAMIC “Dream Kit” How the Compensator Manifold Works: Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more

fl exCIL* Contrast Injection Line • Allows for high pressure injections

• Provides fl exibility

• Various lengths available to provide a single solution for both femoral and radial access

360° Star Handle • Continuous Pressure Monitoring2

• Fewer manipulations3

Unique Star Handle Design• Large gripping surface

Compensator* Manifold • Take pressure readings at any level1

• Integral transducer is 100% tested for accuracy

• Single operator set-up and re-zeroing

• Transducer closer to the pressure source

The NAMIC “Dream Kit”

How the Compensator Manifold Works:

Single Operator Control.

Reduce Contrast Waste.

Less Force to Inject.

For more than 40 years, NAMIC* Fluid Management products have been providing cardiologists, technicians and nurses with the Gold Standard in quality and reliability.As procedures, techniques and clinical requirements continue to evolve, AngioDynamics is committed to bringing you solutions to help meet your lab’s changing needs. Introducing the NAMIC “Dream Kit” through our Fluid Management Convenience Kit program, designed to:• Help increase lab effi ciencies• Reduce number of hand tighten connection points• Minimize contrast waste and maximize contrast budgets• Dual back check valve eliminates the need to turn a stopcock when drawing contrast

PressureTransducer

Compensator Port

OPEN POSITION CLOSED POSITION

Page 3: NAVB 410 NAMIC DreamKit Rev1b - Kimal · The NAMIC “Dream Kit” How the Compensator Manifold Works: Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more

Squeeze* Contrast Controller • Minimize contrast waste by utilizing larger bottles of contrast for multiple patients4

• Prevent cross contamination to the contrast source4

• Green Ball provides air embolization protection when fl uids have depleted from the chamber

• Contrast Management Line available with and without chamber

Acceler-8* Syringe• Slim barrel design designed to reduce the amount of force during injection and aspiration5

• Split collar retention designed to prevent plunger pull out

• Provides smoother aspiration and injection5

Dual Back Check Valve• Decrease hand manipulations

• Allows for single-hand injection

• Designed to aspirate and inject contrast without manual manipulation of a stopcock handle3

1. Must have fl uid fi lled pressure monitoring line attached to Compensator Port and after initial zero at heart level2. Except during injections

3. Fewer manipulations than Standard Manifolds with non-360˚ handles. 4. Refer to contrast manufacturer’s instructions for use5. Data on fi le

Page 4: NAVB 410 NAMIC DreamKit Rev1b - Kimal · The NAMIC “Dream Kit” How the Compensator Manifold Works: Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more

Pre-bonded Manifold Assemblies‡

NAMIC Manifold

Compensator Manifold

Manifold Extension Line Manifold Syringe Extension Line

Type of Manifold Length Tubing TypeNumber of Ports

Handle StyleOn/Off Contrast Port

Saline Fluid Delivery Length

Tubing Type

Convenience Kit Part Number

– – 1 Off Dual Back Check Valve – – – 45627268

15 cm (6”) Extension 2 Star Off – – – – 49000050

– – 2 Star Off Dual Back Check Valve – – – 49000087

– – 2 Star Off Dual Back Check Valve – – – 49000183

– – 2 Star Off Dual Back Check Valve w/Vented Chambered Spike

– 76 cm (30”) LPCIL 49000336

25 cm (10”) fl exCIL 3 Star Off – – 25 cm (10”) LPCIL 48807105

25 cm (10”) fl exCIL 3 Star Off Dual Back Check Valve – – – 48807128

25 cm (10”) fl exCIL 3 Star Off – – – – 49000073

25 cm (10”) fl exCIL 3 Star Off Dual Back Check Valve – 76 cm (30”) LPCIL 49000505

25 cm (10”) fl exCIL 3 Star Off – – 25 cm (10”) fl exCIL 49000147

25 cm (10”) fl exCIL 3 Star Off Dual Back Check Valve – 25 cm (10”) LPCIL 49000500

51 cm (20”) fl exCIL 3 Star Off Dual Back Check Valve – 25 cm (10”) LPCIL 49000086

51 cm (20”) fl exCIL 3 Star Off – – 25 cm (10”) fl exCIL 49000303

51 cm (20”) fl exCIL 3 Star Off Dual Back Check Valve – 51 cm (20”) LPCIL 49000503

51 cm (20”) fl exCIL 3 Star Off Dual Back Check Valve – – – 49000506

76 cm (30”) fl exCIL 3 Star Off Dual Back Check Valve – – – 48807056

76 cm (30”) fl exCIL 3 Star Off Dual Back Check Valve – 25 cm (10”) LPCIL 49000510

– – 3 Star Off Dual Back Check Valve 183 cm Vented Chamber (72”)

– – 48807017

– – 3 Star Off Dual Back Check Valve – 76 cm (30”) LPCIL 48807074

– – 3 Star Off Dual Back Check Valve w/ Chambered Spike

– – – 48807096

– – 3 Star Off Dual Back Check Valve – 25 cm (10”) LPCIL 48807139

– – 3 Star Off Dual Back Check Valve w/ Vented Chambered Spike

– 51 cm (20”) LPCIL 49000055

– – 3 Star Off Dual Back Check Valve – – – 49000187

25 cm (10”) fl exCIL 4 Star Off Dual Back Check Valve – 76 cm (30”) fl exCIL 48807053

25 cm (10”) HPCIL 3 Star Off Dual Back Check Valve – – – 48807034

30 cm (12”) Extension 3 Off Dual Back Check Valve – – – 46627331

46 cm (18”) Extension 3 Off Dual Back Check Valve – – – 49000064

15 cm (6”) Extension 3 Off Dual Back Check Valve – – – 45627384

15 cm (6”) Extension 3 Off Dual Back Check Valve – – – 49000355

– – 2 Off Dual Back Check Valve – – – 49000171Perceptor Manifold

Select a pre-bonded manifold assembly

based on your labs needs.

‡Each pre-bonded kit is set up for right-handed confi guration, with medium manifold pressure. Single sterile numbers and units are not available.

Page 5: NAVB 410 NAMIC DreamKit Rev1b - Kimal · The NAMIC “Dream Kit” How the Compensator Manifold Works: Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more

Barrel Size Plunger Style Barrel Style Fitting0.5 mL Reservoir

Convenience Kit Part Number

Customer UPN Number

Single Sterile Part Number Units

7 mL Thumb Ring Finger Ring Fixed MLL Yes 40083003 H965700830031 Box/25

7 mL Thumb Ring Finger Ring Fixed MLL No 40083013 H965700830131 Box/25

7 mL Thumb Ring Finger Ring Rotating Adaptor Yes 40083007 H965700830071 Box/25

7 mL Thumb Ring Finger Ring Rotating Adaptor No 40083017 H965700830171 Box/25

8 mL Thumb Ring Finger Ring Fixed MLL Yes 40084003 H965700840031 Box/25

8 mL Thumb Ring Finger Ring Fixed MLL No 40084013 H965700840131 Box/25

8 mL Thumb Ring Finger Ring Rotating Adaptor Yes 40084007 H965700830071 Box/25

8 mL Thumb Ring Finger Ring Rotating Adaptor No 40084017 H965700830171 Box/25

10 mL Thumb Ring Finger Ring Fixed MLL Yes 40085003 H965700850031 Box/10

10 mL Thumb Ring Finger RingFixed MLL with 5 cm (2") Extension

Yes 40085004 H965700850041 Box/10

10 mL Thumb Ring Finger Ring Rotating Adaptor Yes 40085007 H965700850071 Box/10

10 mL Thumb Ring Finger Grip Rotating Adaptor Yes 40085107 H965700851071 Box/10

10 mL Thumb Ring Finger Ring Extended RA Yes 40085005 H965700850051 Box/10

10 mL Palm Pad Finger Ring Fixed MLL Yes 40095003 H965700950031 Box/10

10 mL Palm Pad Finger Ring Rotating Adaptor Yes 40095007 H965700950071 Box/10

10 mL Palm Pad Finger Grip Rotating Adaptor Yes 40095107 H965700951071 Box/10

As shown: 70095007

As shown: 70095107

Angiographic Control Syringes

Contrast Management Systems

Squeeze Chamber

Chamber w/ Green Ball

One-WayCheck Valves Tubing Length

Tubing Type Stopcock Fitting

Convenience Kit Part Number

Customer UPN Number

Single Sterile Part Number Units

Yes Yes Yes 183 cm (72") IV NoMale/MaleLuer Lock

40400435 H749904004351 Box/10

No No Yes 183 cm (72”) IV YesMale/MaleLuer Lock

40400010 H965640000101 Box/10

Components

Adult Pressure Monitoring Lines

Fittings LengthConvenience Kit Part Number

Customer UPN Number

Single Sterile Part Number Units

Female–Male 122 cm (48”) 40701482 H965907014821 Box/25

Female–Male 152 cm (60”) 40701602 H965907016021 Box/25

Angiographic GuidewiresODinch

ODmm Length

Tip Description Core Coating

Convenience Kit Part Number

Customer UPN Number

Single Sterile Part Number Units

0.035 <0.94 145 cm 3 mm J Fixed PTFE 19700202 H965970002021† Box/10

0.035 <0.94 175 cm 3 mm J Fixed PTFE 19700210 H965970002101† Box/10

0.035 <0.94 260 cm 3 mm J Fixed PTFE 97000405 H965970004051† Box/10

0.038 <1.01 145 cm 3 mm J Fixed PTFE 19700205 H965970002051† Box/10

0.038 <1.01 175 cm 3 mm J Fixed PTFE 97000211 H965970002111† Box/10

Pressurized or Non-Pressurized

Vented or Non-Vented

Chamber or Spike Head

Tubing Length Stopcock Fitting

Convenience Kit Part Number

Customer UPN Number

Single Sterile Part Number Units

Non-Pressurized Vented Spike Head 4 cm (1.5") 1-way Female 40400039 H965904000391 Box/25

Contrast Controller Spike Assembly

As shown: H749904004351

Page 6: NAVB 410 NAMIC DreamKit Rev1b - Kimal · The NAMIC “Dream Kit” How the Compensator Manifold Works: Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more

USA > 14 Plaza Drive, Latham, NY 12110 > tel: 800-772-6446 or 518-798-1215 > fax: 518-798-1360International > Haaksbergweg 75 (Margriettoren), 1101 BR, Amsterdam Z-O > The Netherlands tel: +31 (0)20 753 2949 > fax: +31 (0)20 753 2939

www.angiodynamics.com

AngioDynamics, the AngioDynamics logo, NAMIC, the NAMIC logo, Compensator, Squeeze, Acceler-8, fl exCIL and Navilyst Medical are trademarks and/or registered trademarks of AngioDynamics, Inc., and affi liate or subsidiary. May be covered by or for use under one or more of the following U.S. patents: 5,533,978; 5,779,666; 5,911,708 and foreign counterparts.

© 2013 AngioDynamics, Inc. NAVB 410 Rev. 1 11/13

Legal Manufacturer:Navilyst Medical, Inc.26 Forest Street, Marlborough, MA 01752

IMPORTANT RISK INFORMATION

Refer to Directions for Use provided with products for indications, complete instructions, warnings, and precautions.

NAMIC COMPENSATOR MANIFOLD

INTENDED USE/INDICATIONS FOR USE: Physiological pressure transducers are utilized during invasive pressure monitoring, catheterization procedures and fl uid delivery.

CONTRAINDICATIONS: None known.

WARNINGS: Do not exceed the following pressures when using this device - Main lumen: Medium Pressure Manifolds —1379 kPa (200 psi/14bar) Static pressure; High Pressure Manifolds—3447 kPa (500 psi/35 bar) Static pressure; Transducer Side Port—41 kPa (6 psi/300 mmHg). Do not use if package is opened or damaged.

PRECAUTIONS: The Compensator line must be completely fi lled with saline to produce accurate pressure readings. The female luer end of the Compensator line (placed in a compatible mounting plate) must be at heart level in order to produce accurate readings. During fl uid injection through the main lumen of the manifold, ensure proper orientation of the handles so that fl uid does not enter the side ports. Do not use transducer Zero/Compensator Port as an injection site for fl uids.

NAMIC SQUEEZE CONTRAST CONTROLLER

INTENDED USE/INDICATIONS FOR USE: The purpose of this system is to minimize contrast waste and allow one container of contrast media to be used on more than one patient.

CONTRAINDICATIONS: None known.

WARNINGS: Maintenance of sterility can only be achieved through proper set-up and use. Use proper aseptic technique when handling this device. Do not attempt to fl ush contrast media or air bubbles back through the contrast delivery system when the Squeeze Contrast Controller chamber is full of fl uid. Flushing back through a full Squeeze chamber could damage the two check valves above the chamber and compromise the sterility of the spike assembly and contrast container. Do not use the spike assembly on more than one container of contrast media. Do not use the tubing assembly on more than one patient. Do not leave the spike assembly intact in a container of contrast for longer than six (6) hours. Do not replace the tubing assembly more than two (2) times. If there is any possibility that contamination may

have occurred during set-up or use, disassemble and set up new sterile product. Ensure that you are making secure connections when using this device to prevent the introduction of air into the system that could result in embolism and in rare instances death. All connections should be fi nger tightened. Over tightening can cause cracks and leaks to occur that could result in embolism and or exposure to biohazards. Examine product carefully for entrapped air and fully debubble prior to injection to minimize the potential for embolism and in rare instances death.

PRECAUTIONS: Carefully read these instructions completely prior to use. The chamber must hang vertically for the green ball to operate effectively.

NAMIC ANGIOGRAPHIC CONTROL SYRINGE

INTENDED USE/INDICATIONS FOR USE: The NAMIC Angiographic Control Syringe is intended to be used for the intraarterial or intravenous administration of radiographic contrast media.

CONTRAINDICATIONS: None known.

WARNINGS: Do not store fl uid in product. Inject immediately after fi lling. This syringe does not have a pressure gauge device. Therefore, it is not intended for balloon catheter infl ation. Over infl ation may result in the rupturing of the balloon.

NAMIC DEVICES: FLUID DELIVERY SETS, CONTRAST INJECTION LINES AND PRESSURE MONITORING LINES

INTENDED USE/INDICATIONS FOR USE: These devices are intended to be used in fl uid management and/or invasive pressure monitoring systems.

NAMIC ANGIOGRAPHIC GUIDEWIRES

INTENDED USE/INDICATIONS FOR USE: The Navilyst Medical Angiographic Guidewires are intended for use in percutaneous introduction of catheters.

CONTRAINDICATIONS: None known.

CAUTION: Federal Law (USA) restricts these devices to sale by or on the order of a physician.

By providing the NAMIC “Dream Kit” through our Convenience

Kit program, you can tailor the accessories and components within

the kit to meet your lab’s needs and provide a full solution for your

angiographic procedures.

Convenience Kit Program

Contact your AngioDynamics NAMIC sales representative to make your dream kit a reality for your lab.

Consult your AngioDynamics representative for country specifi c product availability.† Distributed by Navilyst Medical

Images may not represent actual products

Barrel Size Plunger Style Barrel Style Fitting0.5 mL Reservoir

Convenience Kit Part Number

Customer UPN Number

Single Sterile Part Number Units

7 mL Thumb Ring Finger Ring Fixed MLL Yes 40083003 H965700830031 Box/25

7 mL Thumb Ring Finger Ring Fixed MLL No 40083013 H965700830131 Box/25

7 mL Thumb Ring Finger Ring Rotating Adaptor Yes 40083007 H965700830071 Box/25

7 mL Thumb Ring Finger Ring Rotating Adaptor No 40083017 H965700830171 Box/25

8 mL Thumb Ring Finger Ring Fixed MLL Yes 40084003 H965700840031 Box/25

8 mL Thumb Ring Finger Ring Fixed MLL No 40084013 H965700840131 Box/25

8 mL Thumb Ring Finger Ring Rotating Adaptor Yes 40084007 H965700830071 Box/25

8 mL Thumb Ring Finger Ring Rotating Adaptor No 40084017 H965700830171 Box/25

10 mL Thumb Ring Finger Ring Fixed MLL Yes 40085003 H965700850031 Box/10

10 mL Thumb Ring Finger RingFixed MLL with 5 cm (2") Extension

Yes 40085004 H965700850041 Box/10

10 mL Thumb Ring Finger Ring Rotating Adaptor Yes 40085007 H965700850071 Box/10

10 mL Thumb Ring Finger Grip Rotating Adaptor Yes 40085107 H965700851071 Box/10

10 mL Thumb Ring Finger Ring Extended RA Yes 40085005 H965700850051 Box/10

10 mL Palm Pad Finger Ring Fixed MLL Yes 40095003 H965700950031 Box/10

10 mL Palm Pad Finger Ring Rotating Adaptor Yes 40095007 H965700950071 Box/10

10 mL Palm Pad Finger Grip Rotating Adaptor Yes 40095107 H965700951071 Box/10

Pressurized or Non-Pressurized

Vented or Non-Vented

Chamber or Spike Head

Tubing Length Stopcock Fitting

Convenience Kit Part Number

Customer UPN Number

Single Sterile Part Number Units

Non-Pressurized Vented Spike Head 4 cm (1.5") 1-way Female 40400039 H965904000391 Box/25