Natural Gas Solutions

74
Natural Gas Solutions A complete product offering

Transcript of Natural Gas Solutions

Page 1: Natural Gas Solutions

1

Natural Gas SolutionsA complete product offering

Page 2: Natural Gas Solutions

3

O.M.T. TARTARINIGas pressure regulating and metering stations.Pressure regulators, slam-shut valves, safetyvalves and accessories. Remote controlequipment. Engineering, adaption of existinginstallation to meet current standardrequirements. Theoretical and practicaltraining.

Page 3: Natural Gas Solutions

4

QQQQQuuuuualitalitalitalitalityyyyy

The term “quality” can have different meanings.When applied to a company, it means organization’squality and products’ quality. These terms have aprecise definition in standards regulating thefunctioning of organizations and products.

We can definitely state that EMERSON NATURALGAS COMPANIES are outstanding both in theirorganization and the quality of their products.

The EMERSON NATURAL GAS COMPANIES QualitySystems regulating the functioning of thecompanies’ organizations have been recognized ascomplying with UNI EN ISO 9001 since 1991 forTARTARINI, and NF EN ISO 9001 since 1996 forFRANCEL.

We can state that company activities are correctlyand efficiently carried out and widely supported bythe most up-to-date computer technologies.

EMERSON NATURAL GAS COMPANIES productshave been type-approved for use by leadingdistribution companies, such as GDF, TRACTEBEL,SNAM, ITALGAS, AEM, British Gas, Gasunie, GasNatural, Enargas, Phoenix Gas, Bord Gáis Éireann,Metrogas, SPP, BOTAS, IGDAS and many others.

In addition most of the international recognizedindependent organizations, such as ISPEL, DVGW,TÜV, SZU, TSU, CESI, MBH, JKJ, IGNiG, TSE, UDT,FTZU, BARBARA, GOST.

Type-approvals have been obtained followingextremely severe and selective tests carried outaccording to standards and customers’ productspecifications.

These type-approvals are a further confirmation ofEMERSON NATURAL GAS COMPANIES capabilitiesand high quality products.

GAS DEL ESTADO

Data

Page 4: Natural Gas Solutions

5

QualityQualityQualityQualityQuality ..................................................................................................................................................... 4

ContentsContentsContentsContentsContents ................................................................................................................................................. 5-8

----- REREREREREGGGGGULAULAULAULAULATTTTTOOOOORRRRRSSSSS

AxiAxiAxiAxiAxial floal floal floal floal flow pw pw pw pw piiiiilololololot-ot-ot-ot-ot-opepepepeperrrrraaaaattttted red red red red regulegulegulegulegulaaaaatttttororororor, bal, bal, bal, bal, balancancancancanced ped ped ped ped plululululugggggFL Series ................................................................................................................................................ 9FL-BP Series ........................................................................................................................................... 10

“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” glo” glo” glo” glo” globe tbe tbe tbe tbe tyyyyype ppe ppe ppe ppe piiiiilololololot-ot-ot-ot-ot-opepepepeperrrrraaaaattttted red red red red regulegulegulegulegulaaaaatttttororororor, bal, bal, bal, bal, balancancancancanced ped ped ped ped plululululugggggMP Series ............................................................................................................................................... 111098-EGR Series ..................................................................................................................................... 12EZH Series .............................................................................................................................................. 13Cronos Series ......................................................................................................................................... 14Cronos Series ......................................................................................................................................... 15

“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” glo” glo” glo” glo” globe tbe tbe tbe tbe tyyyyype ppe ppe ppe ppe piiiiilololololot-ot-ot-ot-ot-opepepepeperrrrraaaaattttted red red red red regulegulegulegulegulaaaaatttttororororor, boo, boo, boo, boo, boot tt tt tt tt tyyyyypepepepepeMPS Series ............................................................................................................................................. 16ASOFLEX Series ...................................................................................................................................... 17EZR Series .............................................................................................................................................. 18

Multi-fMulti-fMulti-fMulti-fMulti-funcuncuncuncunctititititionononononal pal pal pal pal piiiiilololololot-ot-ot-ot-ot-opepepepeperrrrraaaaattttted red red red red regulegulegulegulegulaaaaatttttororororor, bal, bal, bal, bal, balancancancancanced ped ped ped ped plululululugggggK Series ................................................................................................................................................. 19

GGGGGlololololobe tbe tbe tbe tbe tyyyyype ppe ppe ppe ppe piiiiilololololot-ot-ot-ot-ot-opepepepeperrrrraaaaattttted red red red red regulegulegulegulegulaaaaatttttororororor, bal, bal, bal, bal, balancancancancanced ped ped ped ped plululululuggggg971 Series .............................................................................................................................................. 20

Compact regulator with integrated slam shut valve, balanced plugCompact regulator with integrated slam shut valve, balanced plugCompact regulator with integrated slam shut valve, balanced plugCompact regulator with integrated slam shut valve, balanced plugCompact regulator with integrated slam shut valve, balanced plug• Pne• Pne• Pne• Pne• Pneumumumumumaaaaatititititic-loc-loc-loc-loc-loaaaaaded rded rded rded rded regulegulegulegulegulaaaaatttttor • Sor • Sor • Sor • Sor • Sppppprrrrrinininining-log-log-log-log-loaaaaaded rded rded rded rded regulegulegulegulegulaaaaatttttororororor, bal, bal, bal, bal, balancancancancanced ped ped ped ped plululululuggggg

DRPN Series ........................................................................................................................................... 21Auxiliary regulators type 67 and 1301 ..................................................................................................... 22

RP/10 Model .......................................................................................................................................... 23

RLC/20 Model ........................................................................................................................................ 24

MN-MF Series ........................................................................................................................................ 25MR Series ............................................................................................................................................... 25REGAL3 Series ........................................................................................................................................ 26REGAL2 Series ........................................................................................................................................ 27BPZ MPZ Series ...................................................................................................................................... 28

A/100 Series .......................................................................................................................................... 29A/140 Series .......................................................................................................................................... 30RP Series ................................................................................................................................................ 31B/240 Series ........................................................................................................................................... 32627 Series .............................................................................................................................................. 33R Series .................................................................................................................................................. 34B Series .................................................................................................................................................. 35BSV Series .............................................................................................................................................. 36

Contents

AAAAA

Page

Page 5: Natural Gas Solutions

6

----- SILENCERSSILENCERSSILENCERSSILENCERSSILENCERS

Silencers for pressure regulators and gas pressure regulating installationsSilencers for pressure regulators and gas pressure regulating installationsSilencers for pressure regulators and gas pressure regulating installationsSilencers for pressure regulators and gas pressure regulating installationsSilencers for pressure regulators and gas pressure regulating installationsSR - SRS - STP - STL Series ....................................................................................................................... 37

----- SLAM SHUSLAM SHUSLAM SHUSLAM SHUSLAM SHUT VALT VALT VALT VALT VALVEVEVEVEVESSSSS

Axial flow slam shut valve sleeve closing member manual resetAxial flow slam shut valve sleeve closing member manual resetAxial flow slam shut valve sleeve closing member manual resetAxial flow slam shut valve sleeve closing member manual resetAxial flow slam shut valve sleeve closing member manual resetBM5 Series ............................................................................................................................................. 38

Axial flow slam shut valve disc closing member manual resetAxial flow slam shut valve disc closing member manual resetAxial flow slam shut valve disc closing member manual resetAxial flow slam shut valve disc closing member manual resetAxial flow slam shut valve disc closing member manual reset BM6X Series .......................................................................................................................................... 39

Slam shut release relay manual resetSlam shut release relay manual resetSlam shut release relay manual resetSlam shut release relay manual resetSlam shut release relay manual resetOS2-OSD2 Series ................................................................................................................................... 40

Globe plug style slam shut valve manual resetGlobe plug style slam shut valve manual resetGlobe plug style slam shut valve manual resetGlobe plug style slam shut valve manual resetGlobe plug style slam shut valve manual resetOSE-VSE Series ....................................................................................................................................... 41

Slam shut release relay manual resetSlam shut release relay manual resetSlam shut release relay manual resetSlam shut release relay manual resetSlam shut release relay manual resetVSX2 Series ........................................................................................................................................... 42

Disc slam shut valve manual resetDisc slam shut valve manual resetDisc slam shut valve manual resetDisc slam shut valve manual resetDisc slam shut valve manual resetBM7 Series ............................................................................................................................................. 43

Pilot-operated relief valvePilot-operated relief valvePilot-operated relief valvePilot-operated relief valvePilot-operated relief valveVS-FL Series ........................................................................................................................................... 44

----- RELIRELIRELIRELIRELIEF VALEF VALEF VALEF VALEF VALVEVEVEVEVESSSSS

Spring-loaded relief valveSpring-loaded relief valveSpring-loaded relief valveSpring-loaded relief valveSpring-loaded relief valveV Series ................................................................................................................................................. 45

V/20-2 Model ......................................................................................................................................... 45

----- VALVALVALVALVALVEVEVEVEVESSSSS

Floating ball valveFloating ball valveFloating ball valveFloating ball valveFloating ball valveTQ Series ............................................................................................................................................... 46

TTTTTrrrrrunniunniunniunniunnion ball von ball von ball von ball von ball valalalalalvvvvveeeeeTM Series ............................................................................................................................................... 47

Butterfly valve soft sealed bodyButterfly valve soft sealed bodyButterfly valve soft sealed bodyButterfly valve soft sealed bodyButterfly valve soft sealed bodyVFA Series .............................................................................................................................................. 48

----- HEHEHEHEHEAAAAAT EXCHANGT EXCHANGT EXCHANGT EXCHANGT EXCHANGERERERERERSSSSS

TTTTTuuuuube bbe bbe bbe bbe bununununundle hedle hedle hedle hedle heaaaaat et et et et exxxxxccccchhhhhananananangegegegegerrrrrsssssCN-CF Series ......................................................................................................................................... 49

SV Series ............................................................................................................................................... 49

Contents (continued)

BBBBB

CCCCC

DDDDD

EEEEE

FFFFF

Page

Page 6: Natural Gas Solutions

7

----- FIFIFIFIFILLLLLTERTERTERTERTERSSSSS

High pressure cartridge filterHigh pressure cartridge filterHigh pressure cartridge filterHigh pressure cartridge filterHigh pressure cartridge filterFA Series ................................................................................................................................................ 50

Low pressure cartridge filterLow pressure cartridge filterLow pressure cartridge filterLow pressure cartridge filterLow pressure cartridge filterFAG Series .............................................................................................................................................. 51

Filter 160 m3/h ....................................................................................................................................... 52

----- ODORIZERSODORIZERSODORIZERSODORIZERSODORIZERS

Injection odorizing systemInjection odorizing systemInjection odorizing systemInjection odorizing systemInjection odorizing systemDosaodor ............................................................................................................................................... 53

Dosaodor-D ............................................................................................................................................ 54

Absorption odorizing systemAbsorption odorizing systemAbsorption odorizing systemAbsorption odorizing systemAbsorption odorizing systemOL Series ............................................................................................................................................... 55

Injection gas conditioning systemInjection gas conditioning systemInjection gas conditioning systemInjection gas conditioning systemInjection gas conditioning systemGas conditioning unit .............................................................................................................................. 56

----- RERERERERECCCCCOOOOORDERRDERRDERRDERRDERS AND DAS AND DAS AND DAS AND DAS AND DATTTTTA CA CA CA CA COOOOOMPMPMPMPMPUUUUUTERTERTERTERTERSSSSS

Pressure RecorderPressure RecorderPressure RecorderPressure RecorderPressure Recorder ................................................................................................................................. 57

Pressure and temperature recorderPressure and temperature recorderPressure and temperature recorderPressure and temperature recorderPressure and temperature recorder ................................................................................................. 58

Flow rate Pressure-temperature recorderFlow rate Pressure-temperature recorderFlow rate Pressure-temperature recorderFlow rate Pressure-temperature recorderFlow rate Pressure-temperature recorderTriplex .................................................................................................................................................... 59

Flow computer - Flow rate and energy measurementFlow computer - Flow rate and energy measurementFlow computer - Flow rate and energy measurementFlow computer - Flow rate and energy measurementFlow computer - Flow rate and energy measurementFlowti Computer .................................................................................................................................... 60

Flow corrector volumetric flow rate measurement intrinsic safety EEx iaFlow corrector volumetric flow rate measurement intrinsic safety EEx iaFlow corrector volumetric flow rate measurement intrinsic safety EEx iaFlow corrector volumetric flow rate measurement intrinsic safety EEx iaFlow corrector volumetric flow rate measurement intrinsic safety EEx iaFlowti Corrector ..................................................................................................................................... 61

Data logger multifunctional computer/logger intrinsic safety EEx iaData logger multifunctional computer/logger intrinsic safety EEx iaData logger multifunctional computer/logger intrinsic safety EEx iaData logger multifunctional computer/logger intrinsic safety EEx iaData logger multifunctional computer/logger intrinsic safety EEx iaLogti-T600 Series ................................................................................................................................... 62

Data logger for impulse acquisition from meters or flow correctorsData logger for impulse acquisition from meters or flow correctorsData logger for impulse acquisition from meters or flow correctorsData logger for impulse acquisition from meters or flow correctorsData logger for impulse acquisition from meters or flow correctorsT-Log ..................................................................................................................................................... 63

Remote control systemRemote control systemRemote control systemRemote control systemRemote control systemLC 21 Series ........................................................................................................................................... 64

----- UNDERUNDERUNDERUNDERUNDERGGGGGRRRRROOOOOUND SUND SUND SUND SUND STTTTTAAAAATITITITITIOOOOONNNNNSSSSS

Underground modulesUnderground modulesUnderground modulesUnderground modulesUnderground modulesMIF • MI-VP • MIC • MIR Series ............................................................................................................. 65

ME 2 • ME 3 • ME 4 • ME 5 • K1000 Series ............................................................................................ 66

Contents (continued)

HHHHH

IIIII

JJJJJ

GGGGGPage

Page 7: Natural Gas Solutions

8

----- AFTER-SALESAFTER-SALESAFTER-SALESAFTER-SALESAFTER-SALES

AAAAAfffffttttteeeeer-sr-sr-sr-sr-salealealealeales ss ss ss ss seeeeerrrrrviviviviviccccceeeee ...................................................................................................................... 67

Spare PartsSpare PartsSpare PartsSpare PartsSpare Parts .................................................................................................................................. 68

QQQQQuiuiuiuiuick Seck Seck Seck Seck Selecleclecleclectitititition Ron Ron Ron Ron Regulegulegulegulegulaaaaatttttor Tor Tor Tor Tor Taaaaabbbbblelelelele ................................................................................................ 69

Regulating and Metering installations - Final Regulating installationsRegulating and Metering installations - Final Regulating installationsRegulating and Metering installations - Final Regulating installationsRegulating and Metering installations - Final Regulating installationsRegulating and Metering installations - Final Regulating installations .......................... 70

Contents (continued)

KKKKKPage

Page 8: Natural Gas Solutions

9

A

FL Series

Axial flow pilot-operated regulatorAxial flow pilot-operated regulatorAxial flow pilot-operated regulatorAxial flow pilot-operated regulatorAxial flow pilot-operated regulatorbalanced plugbalanced plugbalanced plugbalanced plugbalanced plug

BFL with OS/80X-MP and PS/80

FL with PS/79

MFL with PS/79

TypesFLFLFLFLFL : regulator or monitorMFLMFLMFLMFLMFL : regulator and built-in monitorBFLBFLBFLBFLBFL : regulator and built-in slam shut valve

Technical specificationsAllowable pressure PS : up to 100 barInlet pressure range bpe : 1 to 100 barSet range Wh : 0.5 to 80 barMinimum operating differential pressure ∆Pmin : 0.5 barAccuracy class AC : up to ± 1 %Lock-up pressure class SG : up to + 5 %Class of lock-up pressure zone SZ : up to 5 %Flow rate coefficient Cg : up to 17500

Built-in slam shut valveIndependent pneumatic controlManual resetAccuracy class AG : up to ± 1 %Response time ta : ≤ 1 sec.

Size1” • 1½” • 2” • 2½” • 3” • 4” • 6”

Flanged connectionsSame inlet and outlet1” • 1½” • 2” • 2½” • 3” • 4” • 6” (FL type only)Different inlet and outlet1”x 4” • 1½”x 6” • 2”x 6” • 2½”x 8” • 3”x10” • 4”x10”(6”x12” FL type only)

Flange ratingANSI 300, 600

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsSame inlet and outlet flangesLarger outlet flangeBuilt-in SR silencerSRS silencerPrearrangement for remote alarms and controls

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)Sour gases (NACE standards)

Page 9: Natural Gas Solutions

10

A

MFL-BP with PS/79-2

FL-BP with PS/79-1

AxiAxiAxiAxiAxial flal flal flal flal flooooow piw piw piw piw pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaattttted red red red red regulegulegulegulegulaaaaatttttooooorrrrrbalanced plugbalanced plugbalanced plugbalanced plugbalanced plug

FL-BP Series

BFL-BP with OS/80X-BP and PS/79-1

TypesFL-BPFL-BPFL-BPFL-BPFL-BP : regulator or monitorMFL-BPMFL-BPMFL-BPMFL-BPMFL-BP : regulator and built-in monitorBFL-BPBFL-BPBFL-BPBFL-BPBFL-BP : regulator and built-in slam shut valve

Technical specificationsAllowable pressure PS : up to 25 barInlet pressure range bpe : 0.2 to 25 barSet range Wh : 0.01 to 8 barMinimum operating differential pressure ∆Pmin : 0.2 barAccuracy class AC : up to ± 1 %Lock-up pressure class SG : up to + 5 %Class of lock-up pressure zone SZ : up to 5 %Flow rate coefficient Cg : up to 17500

Built-in slam shut valveIndependent pneumatic controlManual resetAccuracy class AG : up to ± 1 %Response time ta : ≤ 1 sec.

Size1” • 1½” • 2” • 2½” • 3” • 4” • 6”

Flanged connectionsSame inlet and outlet1” • 1½” • 2” • 2½” • 3”• 4”• 6” (FL-BP type only)Different inlet and outlet1”x 4” • 1½”x 6” • 2”x 6” • 2½”x 8” • 3”x10” • 4”x10”(6”x12” FL-BP type only)

Flange ratingPN 16, 25 UNI/DINANSI 150

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsSame inlet and outlet flangesLarger outlet flangeBuilt-in SR silencerSRS silencerPrearrangement for remotealarms and controls

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 10: Natural Gas Solutions

11

A

TypesMP NOMP NOMP NOMP NOMP NO : regulator - fail to openMP NFMP NFMP NFMP NFMP NF : regulator - fail to close

Technical specificationAllowable pressure PS : up to 85 barInlet pressure range bpe : 1 to 85 barSet range Wh : 1 to 70 barMinimum operating differential pressure ∆Pmin : 0.5 barAccuracy class AC : 2.5Lock-up pressure class SG : 5Class of lock up pressure zone SZ : 5Flow rate coefficient Cg : up to 25480- with reduced trim type 1 : up to 12916- with reduced trim type 2 : up to 7468

Built in slam shut valveIndependent pneumatic controlManual resetAccuracy class AG : 2.5Response time ta : < 1s

Flanged connections1” • 2” • 3” • 4” • 6” • 8”

Flange ratingANSI 150, 300, 600

Temperature1” : -30°C +60°C2” - 8” : -20°C +60°C

ConfigurationIntegral Slam ShutRestricted TrimLow Temperature (Gas heater)Pre-arrangement for remote alarms and control

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” gl” gl” gl” gl” glooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttedededededrrrrregulegulegulegulegulaaaaatttttooooorrrrr, bal, bal, bal, bal, balanananananccccced ped ped ped ped plululululuggggg

Type MP with compact piloting system

MP Series

Page 11: Natural Gas Solutions

12

A“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” gl” gl” gl” gl” glooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttededededed

rrrrregulegulegulegulegulaaaaatttttooooorrrrr, bal, bal, bal, bal, balanananananccccced ped ped ped ped plululululuggggg

1098-EGR Series

Type 1098-EGR with integrated RegFlo

Types1098-E1098-E1098-E1098-E1098-EGGGGGRRRRR : regulator

Technical specificationsAllowable pressure PS : up to27 barInlet pressure range bpe : up to 20 barSet range Wh : 0.005 to 20 barMinimum operating differential pressure ∆Pmin : < 0.5 barAccuracy class AC : 2.5Lock-up pressure class SG : 5Class of lock up pressure zone SZ : 5Flow rate coefficient Cg : up to 13600

Flanged connections1” • 2” • 3” • 4” • 6”

Flange ratingANSI 150, 300

TemperatureStandard : -30°C +80°C

ConfigurationLow Noise TrimPre-arrangement for remote alarms and controlRegflo AdaptionLow Temperature

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 12: Natural Gas Solutions

13

A

TypesEEEEEZHZHZHZHZH : regulator or relief

Technical specificationAllowable pressure PS : up to 100 barInlet pressure range bpe : 0.5 to 100 barSet range Wh : 0.5 to 80 barMinimum operating differential pressure ∆Pmin : 1 barAccuracy class AC : 2.5Lock-up pressure class SG : 5Class of lock up pressure zone SZ : 5Flow rate coefficient Cg : up to 2470

Built in slam shut valveIndependent pneumatic controlManual resetAccuracy class AG : 2.5Response time ta : < 1s

Flanged connections1” • 2” • 3” • 4” • 6” • 8”

Flange ratingANSI 150, 300, 600

TemperatureStandard : -30°C +80°C

ConfigurationIntegral Slam ShutRestricted TrimRelief ConstructionRegFlo AdaptionPre-arrangement for remote alarms and control

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” gl” gl” gl” gl” glooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttedededededrrrrregulegulegulegulegulaaaaatttttooooorrrrr, bal, bal, bal, bal, balanananananccccced ped ped ped ped plululululuggggg

Type EZH with APX pilot

Type APX Pilot

Type Compact Pilot

EZH Series

Type EZH with slam shutand compact pilot

Page 13: Natural Gas Solutions

14

A“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” gl” gl” gl” gl” glooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttededededed

rrrrregulegulegulegulegulaaaaatttttooooorrrrr, , , , , balbalbalbalbalanananananccccced ped ped ped ped plululululuggggg

CC

CCB

C

CB

Cronos Series

CCB - SRS

TypesCCCCC : regulatorCBCBCBCBCB : regulator and built-in monitorCCCCCCCCCC : regulator and monitorCCBCCBCCBCCBCCB : regulator monitor and built-in slam shut valve

Technical specificationsFlanges PN25/40 - ANSI 300/600Allowable pressure PS : up to 100 barInlet pressure range bpe : 1 to 100 barSet range Wh : 0.5 to 80 barMinimum operating differential pressure ∆Pmin : 0.5 barFlanges PN16 - ANSI 150Allowable pressure PS : up to 20 barInlet pressure range bpe : 0.2 to 20 barSet range Wh : 0.01 to 8 barMinimum operating differential pressure ∆Pmin : 0.2 barAccuracy class AC : up to ± 1%Lock-up pressure class SG : up to ± 5%Class of lock-up pressure zone SZ : up to 5%Flow rate coefficient Cg : up to 5200

Built-in slam shut valveIndependent pneumatic controlAccuracy class AG : ± 1%Response time ta : ≤ 1 sec.

Size 1” • 2” • 3”

Flanged connectionsSame inlet and outlet 1” • 2” • 3”Different inlet and outlet 1”x 4” • 2”x 6” • 3”x10”

Flange ratingPN 16, 25, 40 UNI/DINANSI 150, 300, 600

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °CConfigurationsSame inlet and outlet flangesLarger outlet flangeBuilt-in SR silencerSRS silencerPrearrangement for remotealarms and controls90° outlet

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 14: Natural Gas Solutions

15

A

CCO

CCBO

CO

CBO

Cronos Series

“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” gl” gl” gl” gl” glooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttedededededrrrrregulegulegulegulegulaaaaatttttooooorrrrr, , , , , balbalbalbalbalanananananccccced ped ped ped ped plululululuggggg

CCBO - SRS

TypesCCCCCOOOOO : regulatorCBCBCBCBCBOOOOO : regulator and built-in monitorCCCCCCCCCCOOOOO : regulator and monitorCCBCCBCCBCCBCCBOOOOO : regulator monitor and built-in slam shut valve

Technical specificationsFlanges PN25/40 - ANSI 300/600Allowable pressure PS : up to 100 barInlet pressure range bpe : 1.5 to 100 barSet range Wh : 1 to 40 barMinimum operating differential pressure ∆Pmin : 0.5 barFlanges PN16 - ANSI 150Allowable pressure PS : up to 20 barInlet pressure range bpe : 1.5 to 20 barSet range Wh : 1 to 18 barMinimum operating differential pressure ∆Pmin : 0.3 barAccuracy class AC : up to ± 1%Lock-up pressure class SG : up to ± 5%Class of lock-up pressure zone SZ : up to 5%Flow rate coefficient Cg : up to 4400

Built-in slam shut valveIndependent pneumatic controlAccuracy class AG : ± 1%Response time ta : ≤ 1 sec.

Size 1” • 2” • 3”

Flanged connectionsSame inlet and outlet 1” • 2” • 3”Different inlet and outlet 1”x 4” • 2”x 6” • 3”x10”

Flange ratingPN 16, 25, 40 UNI/DINANSI 150, 300, 600

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °CConfigurationsSame inlet and outlet flangesLarger outlet flangeSRS silencerPrearrangement for remotealarms and controls

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 15: Natural Gas Solutions

16

A“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” gl” gl” gl” gl” glooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttededededed

rrrrregulegulegulegulegulaaaaatttttooooorrrrr, boo, boo, boo, boo, boot tt tt tt tt typypypypypeeeee

MPS SeriesTypesMPSIMPSIMPSIMPSIMPSI : Regulator - Internal pilot supply versionMPSEMPSEMPSEMPSEMPSE : Regulator - External pilot supply version

Technical specificationAllowable pressure PS : up to 85 barInlet pressure range bpe : 1 to 85 barSet range Wh : 1 to 70 barMinimum operating differential pressure ∆Pmin : 1 barAccuracy class AC : 2.5Lock-up pressure class SG : 5Class of lock up pressure zone SZ : 5Flow rate coefficient Cg : up to 3528- with reduced trim type 1 : up to 1960- with reduced trim type 2 : up to 980

Built in slam shut valveIndependent pneumatic controlManual resetAccuracy class AG : 2.5Response time ta : < 1s

Flanged connections1” • 2” • 3” • 4”

Flange ratingANSI 300, 600

Temperature1” : -30°C +60°C2” - 4” : -20°C +60°C

ConfigurationIntegral Slam ShutLow Temperature (Gas heater)Pre-arrangement for remote alarms and control

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Type MPS

Page 16: Natural Gas Solutions

17

A

TypesAAAAAsssssoooooflefleflefleflexxxxx : regulator

Technical specificationsAllowable pressure PS : up to25 barInlet pressure range bpe : 0.7 to 25 barSet range Wh : 0.01 to 16 barMinimum operating differential pressure ∆Pmin : 0.7 barAccuracy class AC : 2.5Lock-up pressure class SG : 5Class of lock up pressure zone SZ : 5Flow rate coefficient Cg : up to 5800Noise level dBA : up to 70

Built in slam shut valveIndependent pneumatic controlManual resetAccuracy class AG : 2.5Response time ta : < 1s

Flanged connections2” • 3” • 4” • 6”

Flange ratingANSI 150, 300

TemperatureStandard : -20°C +60°C

ConfigurationIntegral Slam ShutLow Noise TrimPre-arrangement for remote alarms and controlLow Temperature (Gas heater)

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” gl” gl” gl” gl” glooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttedededededrrrrregulegulegulegulegulaaaaatttttooooorrrrr, boo, boo, boo, boo, boot tt tt tt tt typypypypypeeeee

Type ASOFLEX with integratedOS2 slam shut valve

ASOFLEX

Type ASOFLEX withoutslam shut valve

Page 17: Natural Gas Solutions

18

A

TypesEEEEEZRZRZRZRZR : regulator or relief

Technical specificationsAllowable pressure PS : up to 72,4 barInlet pressure range bpe : 0.5 to 52 barSet range Wh : 0.5 to 48 barMinimum operating differential pressure ∆Pmin : 1 barAccuracy class AC : 2.5Lock-up pressure class SG : 5Class of lock up pressure zone SZ : 5Flow rate coefficient Cg : up to 11200- with reduced trim type 60% : up to 7150- with reduced trim type 30% : up to 3570

Built in slam shut valveIndependent pneumatic controlManual resetAccuracy class AG : 2.5Response time ta : < 1s

Flanged connections1” • 2” • 3” • 4” • 6” • 8x6”

Flange ratingANSI 150, 300, 600

TemperatureStandard : -30°C +80°C

ConfigurationIntegral Slam ShutRestricted TrimRelief ConstructionRegFlo AdaptionLow TemperaturePre-arrangement for remote alarms and control

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

“““““TTTTTooooop ep ep ep ep ennnnntrtrtrtrtryyyyy” gl” gl” gl” gl” glooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttedededededrrrrregulegulegulegulegulaaaaatttttooooorrrrr, boo, boo, boo, boo, boot tt tt tt tt typypypypypeeeee

Type EZR Regulator

Type EZR with integratedOS2 slam shut valve

EZR Series

Page 18: Natural Gas Solutions

19

A

TypesK1000HPK1000HPK1000HPK1000HPK1000HP : regulator - transmissionK1000K1000K1000K1000K1000 : regulator - distributionK3000K3000K3000K3000K3000 : regulator - distribution

Technical specificationsAllowable pressure K1000 HP PS : up to 100 bar

K1000 / K3000 PS : up to 25 barInlet pressure range bpe : 1 to 85 barSet range Wh : 0.01 to 85 barMinimum operating differential pressure ∆Pmin : 0.5 barAccuracy class AC : 2.5Lock-up pressure class SG : 5Class of lock up pressure zone SZ : 5Flow rate coefficient Cg : up to 2600

Built in slam shut valveIndependent pneumatic controlManual resetAccuracy class AG : 2.5Response time ta : < 1s

FiltrationPolyester cartridge 5 micron

Flanged connectionsK1000HP : 2” x 3” or 2” x 4”K1000 : 2” x 3”, 2” x 4”K3000 : 3” x 6”

Flange ratingPN16/25, ANSI 600

TemperatureAll types : -20°C +60°C

ConfigurationCompact PilotPre-arrangement for remote alarms and controlLow Temperature (Gas heater)

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Multi-functional pilot-operatedMulti-functional pilot-operatedMulti-functional pilot-operatedMulti-functional pilot-operatedMulti-functional pilot-operatedrrrrregulegulegulegulegulaaaaatttttooooorrrrr, bal, bal, bal, bal, balanananananccccced ped ped ped ped plululululuggggg

Type K1000HP

Type K1000

K Series

Page 19: Natural Gas Solutions

20

A

971 Series

GGGGGlllllooooobe tbe tbe tbe tbe typypypypype pie pie pie pie pilllllooooot-ot-ot-ot-ot-opppppeeeeerrrrraaaaatttttedededededrrrrregulegulegulegulegulaaaaatttttooooorrrrr, bal, bal, bal, bal, balanananananccccced ped ped ped ped plululululuggggg

971 with PS/79

Types971971971971971 : regulator971-E971-E971-E971-E971-E : monitor

Technical specificationsBody allowable pressure PS : up to 100 barHighest operating pressure Pmax : 70 barInlet pressure range bpe : 1 to 100 barSet range Wh : 0.5 to 70 barMinimum operating differential pressure ∆Pmin : 0.5 barAccuracy class AC : up to ± 1 %Lock-up pressure class SG : up to + 5 %Class of lock-up pressure zone SZ : up to 5 %Flow rate coefficient Cg : up to 32500

Size10”

Flanged connectionsSame inlet and outlet 10”

Flanging ratingANSI 300, 600

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsBuilt-in silencerPrearrangement for remote alarms and controls

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)Sour gases (NACE standards)

Page 20: Natural Gas Solutions

21

ACompact regulator with integratedCompact regulator with integratedCompact regulator with integratedCompact regulator with integratedCompact regulator with integrated

slslslslslam sham sham sham sham shuuuuut vt vt vt vt valalalalalvvvvveeeee, bal, bal, bal, bal, balanananananccccced ped ped ped ped plululululuggggg

DRPN SeriesTypesDRPN-PILDRPN-PILDRPN-PILDRPN-PILDRPN-PIL : pilot-operated regulatorDRPNDRPNDRPNDRPNDRPN : direct -operated regulator

Technical specificationsDRPN-PILDRPN-PILDRPN-PILDRPN-PILDRPN-PILAllowable pressure PS : 70 barInlet pressure range bpe : up to 70 barSet range Wh : 1 to 10.5 barAccuracy class AC : 2.5Lock-up pressure class SG : 10Flow rate coefficient Cg : 78DRPNDRPNDRPNDRPNDRPNAllowable pressure PS : 70 barInlet pressure range bpe : up to 70 barSet range Wh : 0.5 to 35 barAccuracy class AC : 5Lock-up pressure class SG : 20Flow rate coefficient Cg : 78

Built in slam shut valveManual resetAccuracy class AG : 2.5Response time ta : < 1s

Connections (wafer style)DN25

Flange ratingPN25-100 wafer style

TemperatureStandard : -30°C +71°C

ConfigurationIntegral Slam Shut type OS2Pre-arrangement for remote alarms and controlLow Temperature (Gas heater)

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Type DRPN-OS2

Page 21: Natural Gas Solutions

22

A

Types6767676767 : supply regulator with optional built-in filter

and relief valve1301F1301F1301F1301F1301F : supply or loading regulator

Technical specifications6767676767Allowable pressure PS : 17.2 barInlet pressure range bpe : up to 7.6 barSet range Wh : 0 to 8.6 barAccuracy class AC : 10Lock-up pressure class SG : 20Flow rate (maximal) Qmax : 48 m3/h13011301130113011301Allowable pressure PS : 414 barInlet pressure range bpe : up to 38 barSet range Wh : 0.69 to 34.5 barAccuracy class AC : 10-20Lock-up pressure class SG : 20-30Flow rate (maximal) Qmax : 5800 m3/h

Filtration67- series : 40 micron

ConnectionsAll types : ¼” NPT

TemperatureStandard : -30°C +80°C

ConfigurationSour gas capabilitiesSecond outlet pressure tappingOptional gaugeStainless steel construction on demandLow temperature (-54°C) available

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulator

Type 67CFR

Type 1301F

Auxiliary regulators

Page 22: Natural Gas Solutions

23

A

Pneumatic-loaded regulatorPneumatic-loaded regulatorPneumatic-loaded regulatorPneumatic-loaded regulatorPneumatic-loaded regulator

RP/10 Model

RP/10

Construction features Counterbalanced valve Built-in relief valve Built-in filter Inlet and outlet in-line

Technical specificationsBody allowable pressure PS : 220 barHighest operating pressure Pmax : 30 barInlet pressure range bpe : 1 to 220 barSet range Wh : 0.5 to 30 barAccuracy class AC : up to ± 5 %Lock-up pressure class SG : up to +10 %Class of lock-up pressure zone SZ : up to 10 %

Orifice½”

Threaded connectionsInlet and outlet: ¾” x 1” BSP

TemperatureWorking: -10 °C +60 °CAmbient: -20 °C +80 °C

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 23: Natural Gas Solutions

24

A

Pneumatic-loaded regulatorPneumatic-loaded regulatorPneumatic-loaded regulatorPneumatic-loaded regulatorPneumatic-loaded regulator

RLC/20 Model

RLC/20

Construction featuresCounterbalanced valveInlet and outlet in-line

Technical specificationsBody allowable pressure PS : 320 barHighest operating pressure Pmax : 250 barInlet pressure range bpe : 30 to 320 barSet range Wh : 20 to 250 barMinimum operating differential pressure ∆P min : 10 barAccuracy class AC : up to ± 2.5%Lock-up pressure class SG : up to + 5%Class of lock-up pressure zone SZ : up to 10 %

Built-in relief valveSetting at +5% the regulator setting value

Orifice size¾”

Threaded connectionsInlet and outlet 1” NPT

TemperatureStandard version: gas temperature +5 °C +50 °C

ambient temperature -15 °C +60 °Cstoring temperature -25 °C +80 °C

Low-temperature version: gas temperature +5 °C +50 °Cambient temperature -25 °C +60 °C

storing temperature -42 °C +80 °C

ConfigurationsRelief valveWelding flangesThreaded flangesFilter

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 24: Natural Gas Solutions

25

A

Types MN-MFMN, MFMN, MFMN, MFMN, MFMN, MF : regulator without slam shut valveMBN, MBFMBN, MBFMBN, MBFMBN, MBFMBN, MBF : regulator with slam shut valveMBN-M, MBF-MMBN-M, MBF-MMBN-M, MBF-MMBN-M, MBF-MMBN-M, MBF-M : monitor with slam shut valveTypes MRMRMRMRMRMR : regulator without slam shut valveMBRMBRMBRMBRMBR : regulator with slam shut valve

Construction featuresCounterbalanced valve • Manual reset • Overpressure andunderpressure slam shut valve • Inlet and outlet in-line • Largeroutlet flange (except MR series)

Technical specificationsAllowable pressure :MN-MF Series - body PS : up to 20 bar

- actuator PS : 4 barMR Series PS : up to 19 barHighest operating pressure MN-MF Series Pmax : 3 barPermissible inlet pressure Pe,max : up to 19 barInlet pressure range bpe : 0.2 to 19 barSet range- standard version Wh : 10 to 500 mbar- AP version Wh : 0.5 to 1 bar- APA version Wh : 1 to 3 barAccuracy class AC : up to ± 5%Lock-up pressure class SG : up to +10%Class of lock-up pressure zone SZ : up to 10%Flow rate coefficient MN-MF Series Cg : up to 4000

MR Series Cg : 1100Built-in slam shut valveIndependent pneumatic controlAccuracy class AG : ± 5%Response time ta : ≤ 1 sec.

SizeMN-MF Series: 1” • 1½” • 2” • 2½” • 3” • 4”MR Series: 2”

Flanged connectionsMN-MF Series:Different inlet and outlet1”x 2½” • 1½”x 3” • 2”x 4” • 2½”x 4” • 3”x 6” • 4”x 8”Same inlet and outlet1” • 1½” • 2” • 3” • 4”MR Series: 2” x 2”

Flange ratingPN 16 UNI/DIN • ANSI 150

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsBuilt-in silencer

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

SSSSSppppprrrrrinininining-log-log-log-log-loaaaaaded rded rded rded rded regulegulegulegulegulaaaaatttttororororor, F, F, F, F, Full rull rull rull rull reeeeettttteeeeennnnntititititionononononsssssppppprrrrrinininining-log-log-log-log-loaaaaaded rded rded rded rded regulegulegulegulegulaaaaatttttororororor, bal, bal, bal, bal, balancancancancanced ped ped ped ped plululululuggggg

MBN-M/

MN-MF SeriesMR Series

MBR/

MBN/

MN/

MBF/

Page 25: Natural Gas Solutions

26

A

TypesREGAL3REGAL3REGAL3REGAL3REGAL3 : high or low pressure set-point regulatorCan be equipped with or without slam shut - counter balanced valve

Technical specificationsAllowable pressure PS : 10 barInlet pressure range bpe : up to 10 barSet range Wh : 0.008 to 3 barAccuracy class AC : 10Lock-up pressure class SG : 15Flow rate Qmax : 3400 m3/h

Built in slam shut valveManual resetAccuracy class AG : 5Response time ta : < 1sOver and under pressure slam shut valve

Size2”

ConnectionsPN10/20, ANSI 150, NPT, GAZ

TemperatureStandard : -30°C +71°C

ConfigurationIntegral Slam Shut type OS2 or VSX2Pre-arrangement for remote alarms and control

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorbalanced plugbalanced plugbalanced plugbalanced plugbalanced plug

Type REGAL3-VSX2

Type REGAL3-OS2

REGAL3 Series

Page 26: Natural Gas Solutions

27

A

TypesREGAL2REGAL2REGAL2REGAL2REGAL2 : regulatorCan be equipped with or without slam shut - counter balanced valve

Technical specificationsAllowable pressure PS : 10 barInlet pressure range bpe : up to 10 barSet range Wh : 8 to 320 mbarAccuracy class AC : 10Lock-up pressure class SG : 15Flow rate Qmax : 275 m3/h

Built in slam shut valveManual resetAccuracy class AG : 5Response time ta : < 1sOver and under pressure slam shut valve

Size1” x 1¼” or 1” x 2¼”

ConnectionsPN10/20, ANSI 150, NPT, GAZ

TemperatureStandard : -30°C +71°C

ConfigurationIntegral Slam Shut type VSX2

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorbalanced plugbalanced plugbalanced plugbalanced plugbalanced plug

Type REGAL2-VSX2

REGAL2 Series

Type REGAL2

Page 27: Natural Gas Solutions

28

A

TypesBPZBPZBPZBPZBPZ : pilot-operated regulatorMPZMPZMPZMPZMPZ : direct -operated regulator

Technical specificationsAllowable pressure PS : 4 barSet range Wh : 21-27-300 mbarAccuracy class AC : 5Lock-up pressure class SG : 20Flow rates BPZ : 160 m3/h

MPZ : 208 m3/hBuilt in slam shut valveManual resetAccuracy class AG : 10Response time ta : < 1s

Connections1” x 2¼”

TemperatureStandard : -30°C +71°C

ConfigurationIntegral Slam Shut type VSX2Low temperature (Gas heater)

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Compact regulator with integratedCompact regulator with integratedCompact regulator with integratedCompact regulator with integratedCompact regulator with integratedslslslslslam sham sham sham sham shuuuuut vt vt vt vt valalalalalvvvvveeeee, bal, bal, bal, bal, balanananananccccced ped ped ped ped plululululuggggg

BPZ MPZ Series

Type BPZ withoutslam shut valve

Type BPZ for compact skid

Type BPZ

Page 28: Natural Gas Solutions

29

A

A/102

A/109

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulator

A/100 Series

A/109-AP

TypesA/102 and A/102-APA/102 and A/102-APA/102 and A/102-APA/102 and A/102-APA/102 and A/102-AP : without slam shut valveA/109 and A/109-APA/109 and A/109-APA/109 and A/109-APA/109 and A/109-APA/109 and A/109-AP : with slam shut valve

Construction featuresBuilt-in relief valveOverpressure and underpressure slam shut valveManual resetInlet and outlet in-line

Technical specificationsBody allowable pressure PS : up to 20 barHighest operating pressure Pmax : 300 mbarPermissible inlet pressure Pe,max : 8 barInlet pressure range bpe : 0.1 to 8 barSet range Wh : 10 to 300 mbarAccuracy class AC : up to ± 5%Lock-up pressure class SG : up to +10%Maximum flow rate Qmax : 600 Stm3/h

Built-in slam shut valveIndependent pneumatic controlAccuracy class AG : ± 5%Response time ta : ≤ 1 sec.

Orifice size1/2” • 5/8” • 3/4” • 1”

Threaded connectionsInlet and outlet 2” BSP

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsWithout relief valve

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 29: Natural Gas Solutions

30

A

A/149

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulator

A/140 Series

A/149-AP

TypesA/142 and A/142-APA/142 and A/142-APA/142 and A/142-APA/142 and A/142-APA/142 and A/142-AP : without slam shut valveA/149 and A/149-APA/149 and A/149-APA/149 and A/149-APA/149 and A/149-APA/149 and A/149-AP : with slam shut valve

Construction featuresCounterbalanced valveBuilt-in relief valveOverpressure and underpressure slam shut valveManual resetInlet and outlet in-line

Technical specificationsBody allowable pressure PS : up to 20 barHighest operating pressure Pmax : 300 mbarPermissible inlet pressure Pe,max : 6 barInlet pressure range bpe : 0.1 to 6 barSet range Wh : 10 to 300 mbarAccuracy class AC : up to ± 5%Lock-up pressure class SG : up to +10%Maximum flow rate Qmax : 900 Stm3/h

Built-in slam shut valveIndependent pneumatic controlAccuracy class AG : ± 5%Response time ta : ≤ 1 sec.

Orifice size1 3/16”

Flanged connectionsInlet and outlet: 2”

Flange ratingPN 16 UNI/DIN

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsWithout relief valve

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

A/142

Page 30: Natural Gas Solutions

31

A

RP/022

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorbalanced plugbalanced plugbalanced plugbalanced plugbalanced plug

RP Series

RP/033/66-FS

RP/033/66

TypesRP/011, RP/022, RP/033RP/011, RP/022, RP/033RP/011, RP/022, RP/033RP/011, RP/022, RP/033RP/011, RP/022, RP/033: without slam shut valveRP/011/66, RP/022/66,RP/011/66, RP/022/66,RP/011/66, RP/022/66,RP/011/66, RP/022/66,RP/011/66, RP/022/66, RP/033/66RP/033/66RP/033/66RP/033/66RP/033/66: with slam shut valve

Construction featuresOverpressure and underpressure slam shut valveManual resetInlet and outlet in-line

Technical specificationsAllowable pressure:- body PS : 20 bar- actuator PS : 4 barPermissible inlet pressure Pe,max : 20 barInlet pressure range bpe : 0.2 to 20 barSet range- 022/033 Wh : 0.1 to 4 bar- 011 Wh : 0.1 to 2 barAccuracy class AC : up to ± 5 %Lock-up pressure class SG : up to + 10 %Flow rate coefficient Cg : up to 360

Built-in slam shut valveIndependent pneumatic controlAccuracy class AG : ± 5 %Response time ta : ≤ 1 sec.

Orifice size½” • 11/16” • ¾”

Threaded connectionsRP/011RP/011RP/011RP/011RP/011 Inlet and outlet 1” x 1G” BSPRP/022RP/022RP/022RP/022RP/022 Inlet and outlet 1G” x 2” BSPRP/033RP/033RP/033RP/033RP/033 Inlet and outlet 2” x 3” BSP

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsFlanged connectionsPN 16, 25, 40 UNI/DINANSI 150, 300

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 31: Natural Gas Solutions

32

A

TypesB/242 and B/242-APB/242 and B/242-APB/242 and B/242-APB/242 and B/242-APB/242 and B/242-AP : without slam shut valveB/249 and B/249-APB/249 and B/249-APB/249 and B/249-APB/249 and B/249-APB/249 and B/249-AP : with slam shut valve

Construction featuresCounterbalanced valveBuilt-in relief valveOverpressure and underpressure slam shut valveManual resetInlet and outlet in-line

Technical specificationsBody allowable pressure PS : 20 barHighest operating pressure Pmax : 300 mbarPermissible inlet pressure Pe-max : 6 barInlet pressure range bpe : 0.1 to 6 barSet range Wh : 10 to 300 mbarAccuracy class AC : up to ± 5 %Lock-up pressure class SG : up to +10%Maximum flow rate Qmax : 300 Stm3/h

Built-in slam shut valveIndependent pneumatic controlAccuracy class AG : ± 5 %Response time ta : ≤ 1 sec.

Orifice size11/16”

Threaded connectionsInlet and outlet 1H” BSP

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsBuilt-in filterWithout relief valveFlanged connections DN 40 PN 16 UNI/DIN

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorbalanced plugbalanced plugbalanced plugbalanced plugbalanced plug

B/240 Series

B/242-FS

B/249

B/242

Page 32: Natural Gas Solutions

33

A

Types627627627627627 : high pressure regulator627-VSX2627-VSX2627-VSX2627-VSX2627-VSX2 : regulator with integrated slam shut valve

Technical specifications627627627627627Allowable pressure PS : 100 barSet range Wh : 0.34 to 34 barAccuracy class AC : 15Lock-up pressure class SG : 20Flow rate Qmax : 4600 m3/h627-VSX2627-VSX2627-VSX2627-VSX2627-VSX2Allowable pressure PS : 10 barSet range Wh : 0.5 to 4 barAccuracy class AC : 10Lock-up pressure class SG : 20Flow rate Qmax : 550 m3/h

Built in slam shut valveManual resetAccuracy class AG : 2.5Response time ta : < 1s

Connections627 : ¼”, 1”or 2” NPT (flanged on demand)627-VSX2 : 1” NPT

TemperatureStandard : -30°C +80°C

ConfigurationIntegral Slam Shut type VSX2 (627-VSX2 only)Relief valve

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulator

627 Series

Type 627-VSX2

Page 33: Natural Gas Solutions

34

A

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulator

R Series

R/72

TypesR/70, R/70-APR/70, R/70-APR/70, R/70-APR/70, R/70-APR/70, R/70-AP, R/71, R/71-AP, R/71, R/71-AP, R/71, R/71-AP, R/71, R/71-AP, R/71, R/71-AP : right -angle connectionR/72, R/72-APR/72, R/72-APR/72, R/72-APR/72, R/72-APR/72, R/72-AP, R/72-F, R/72-F, R/72-F, R/72-F, R/72-FS, R/72-FS, R/72-FS, R/72-FS, R/72-FS, R/72-FS-APS-APS-APS-APS-AP,,,,,R/73, R/73-APR/73, R/73-APR/73, R/73-APR/73, R/73-APR/73, R/73-AP, R/74, R/74-AP, R/74, R/74-AP, R/74, R/74-AP, R/74, R/74-AP, R/74, R/74-AP : axial connection

Construction featuresTwo-stage regulationBuilt-in relief valve (for R/70 and R/72 only)Overpressure and underpressure slam shut valveManual resetBuilt-in filter

Technical specificationsR/70, R/71, R/72, R/72-FS, R/73, R/74R/70, R/71, R/72, R/72-FS, R/73, R/74R/70, R/71, R/72, R/72-FS, R/73, R/74R/70, R/71, R/72, R/72-FS, R/73, R/74R/70, R/71, R/72, R/72-FS, R/73, R/74Permissible inlet pressure PS : 6 barInlet pressure range bpe : 0.1 to 6 barSet range Wh : 15 to 70 mbarAccuracy class AC : up to ± 5%Lock-up pressure class SG : up to +10%Flow rate Qmax : 100 Stm3/h

R/70-APR/70-APR/70-APR/70-APR/70-AP, R/71-AP, R/71-AP, R/71-AP, R/71-AP, R/71-AP, R/72-AP, R/72-AP, R/72-AP, R/72-AP, R/72-AP, R/72-F, R/72-F, R/72-F, R/72-F, R/72-FS-APS-APS-APS-APS-AP, R/73-AP, R/73-AP, R/73-AP, R/73-AP, R/73-AP,,,,,R/74-APR/74-APR/74-APR/74-APR/74-APPermissible inlet pressure PS : 10 barInlet pressure range bpe : 0.1 to 10 barSet range Wh : 70 to 300 mbarAccuracy class AC : up to ± 5%Lock-up pressure class SG : up to +10%Flow rate Qmax : 100 Stm3/h

Built-in slam shut valveOverpressure set range Who : 30 to 380 mbarUnderpressure set range Whu : 8 to 155 mbarAccuracy class AG : ± 5%Response time ta : ≤ 1 sec.

Orifice size19/32”

Threaded connectionsR/70, R/70-AP I” x G 1G” BSP (I” x 1 1G” GAS)R/72, R/72-AP 1” BSP (1” GAS)

TemperatureWorking: -20 °C +60 °CAmbient: -30 °C +60 °C

ConfigurationsWithout relief valveWithout underpressure shut-off deviceFlanged axial inlet - outlet DN25 PN16 UNI/DINFlat soft sealBall - tapered metal - to - metal sealInlet and outlet at axial connectionwith rotating ring nutOther connections on request

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

R/70

R/72-FS

Page 34: Natural Gas Solutions

35

A

TypesB-SerieB-SerieB-SerieB-SerieB-Seriesssss : 2 stage regulation, with internal OPSO and

UPSO, excess flow slam shut, built in filter andrelief valve

Technical specificationsAllowable pressure PS : 7 barInlet pressure range bpe : up to 5 barSet range Wh : 9 to 400 mbarAccuracy class AC : 10Lock-up pressure class SG : 20Flow rate (nominal) m3/h : 6, 10, 25, 40, 50Flow rate (maximal) m3/h : 7, 12, 30, 60

Built in shutting deviceManual resetAccuracy class AG : 25Response time ta : < 1s

ConnectionsInlet and outlet ¾” x 1¼” (other connection available on demand)

TemperatureStandard : -30°C +60°C

ConfigurationAdjustable relief valve settingOptional adjustable outlet pressureInlet and outlet; axial, parallel or right-angle connectionInlet : Sphero-conical or flat joint connectionOutlet : Flat meter joint or 1¼” JPG nutVent : 10 mm diameter

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulator

Type B6

Type B10 adjustable

Type B25

Type BCH adjustable

B Series

Type B50

Page 35: Natural Gas Solutions

36

A

Construction featuresTwo-stage regulationBuilt-in relief valveOverpressure and underpressure slam shut valveExcess flow slam shut valveManual resetBuilt-in filterInlet and outlet / axial / parallel / right-angle connectionAttachments with rotating ring nut

Technical specificationsPermissible inlet pressure PS : 5 barInlet pressure range bpe : 0.5 to 5 barSet range Wh : 9 to 70 mbarAccuracy class AC : up to ± 10 %Lock-up pressure class SG : up to + 20 %Flow rate Qmax : up to 25 Stm3/h

Threaded connectionsInlet and outlet: ¾” x 1¼”Other special connections on demand

TemperatureStandard: -20 °C +60 °C

ConfigurationsInlet : Sphero-conical or flat joint connection (without joint)Outlet : Flat meter joint or 1¼” JPG nut (with joint)Vent : Diameter 10

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Spring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulatorSpring-loaded regulator

BSV Series

BSV6-inline

BSV6-U

BSV10-Angle

Page 36: Natural Gas Solutions

37

B

Regulator type MFL/ with silencer SRS

SR

STL

STP

SR SeriesRegulator built-in silencer, multi-pathNoise reduction down to 20 dB(A)

SRS SeriesRegulator built-in silencer, multi-path and multi-stage typeNoise reduction down to 30 dB(A)

STP SeriesAbsorption silencer to be introduced downstream of regulatorsNoise reduction down to 25 dB(A)

STL SeriesSilencer to be introduced into “T” couplings of pipes,multi-path and absorption type.Noise reduction up to 15 dB(A).

SRS

Silencers for pressure regulators andSilencers for pressure regulators andSilencers for pressure regulators andSilencers for pressure regulators andSilencers for pressure regulators andgas pressure regulating installationsgas pressure regulating installationsgas pressure regulating installationsgas pressure regulating installationsgas pressure regulating installations

Page 37: Natural Gas Solutions

38

C

Axial flow slam shut valve sleeveAxial flow slam shut valve sleeveAxial flow slam shut valve sleeveAxial flow slam shut valve sleeveAxial flow slam shut valve sleeveclosing member manual resetclosing member manual resetclosing member manual resetclosing member manual resetclosing member manual reset

Technical specificationsAllowable pressure PS : up to 100 barInlet pressure range bpe : 0 to 100 barOverpressure set range Who : 0.03 to 80 barUnderpressure set range Whu : 0.01 to 80 barAccuracy class AG : up to ± 1 %Response time ta : ≤ 1 sec.Flow rate coefficient Cg : up to 18300

Size1” • 1½” • 2” • 2½” • 3” • 4” • 6”

Flanged connectionsSame inlet and outlet1” • 1½” • 2” • 2½” • 3” • 4” • 6”

Flange ratingPN 16, 25 UNI/DINANSI 150, 300, 600

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ConfigurationsPrearrangement for remote alarms and controls

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

BM5/ with OS/80X-APA-D

BM5/ with OS/84

BM5 Series

BM5/ with OS/80X-BP

Page 38: Natural Gas Solutions

39

C

Technical specificationsAllowable pressure PS : up to 100 barInlet pressure range bpe : 0 to 100 barOverpressure set range Who : 0.03 to 80 barUnderpressure set range Whu : 0.01 to 80 barAccuracy class AG : up to ± 1%Response time ta : ≤ 1 sec.Flow rate coefficient Cg : up to 144000

Size3” • 4” • 6” • 8” • 10” • 12” • 16”

Flanged connectionsSame inlet and outlet3” • 4” • 6” • 8” • 10” • 12” • 16”

Flange ratingANSI 150, 300, 600

TemperatureWorking: -15 °C +60 °CAmbient: -20 °C +80 °C

ConfigurationsPrearrangement for remote alarms and controlsFor right to left and left to right gas flow

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

BM6X/ with OS/84X-R

BM6X/ with OS/84X-S-R

Axial flow slam shut valve discAxial flow slam shut valve discAxial flow slam shut valve discAxial flow slam shut valve discAxial flow slam shut valve discclosing member manual resetclosing member manual resetclosing member manual resetclosing member manual resetclosing member manual reset

BM6X Series

Page 39: Natural Gas Solutions

40

C

Slam shut release relaySlam shut release relaySlam shut release relaySlam shut release relaySlam shut release relaymanual resetmanual resetmanual resetmanual resetmanual reset

TypesFor stand alone slam shuts (OSE, VSE) or integrated slam shuts (MP,MPS, ASOFLEX, EZR, ...)OS2OS2OS2OS2OS2 : release relay 1” to 6” connectionsOSD2OSD2OSD2OSD2OSD2 : release relay 8” to 10” connections

Technical specificationsOverpressure set range Who : 0.01 to 100 barUnderpressure set range Whu : 0.01 to 90 barAccuracy class diaphragm or bellows AG : 2.5

piston AG : 5Response time ta : < 1s

Flanged connectionsOS2 : 1” • 2” • 3” • 4” • 6”OSD2 : 8” • 9” • 10”

TemperatureStandard : -30°C +71°C

ConfigurationDouble stage mechanismHigh shock resistanceAdditional sensorSame sensing mechanism for all valve sizesManual resetPosition indicatorLow TemperatureWater-tightPre-arrangement for remote alarms and control

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

OS2-OSD2 Series

Type OS2

Type OSD2

Page 40: Natural Gas Solutions

41

C

GGGGGlllllooooobe pbe pbe pbe pbe plululululug sg sg sg sg stttttylylylylyle sle sle sle sle slam sham sham sham sham shuuuuut vt vt vt vt valalalalalvvvvveeeeemanual resetmanual resetmanual resetmanual resetmanual reset

TypesOSEOSEOSEOSEOSE : slam shut valve internal bypass (high pressure rating)VSEVSEVSEVSEVSE : slam shut valve (low pressure rating)

Technical specificationsOSEOSEOSEOSEOSEAllowable pressure PS : up to 100 barInlet pressure range bpe : 0 to 100 barOverpressure set range Who : 0.01 to 100 barUnderpressure set range Whu : 0.01 to 90 barFlow rate coefficient Cg : up to 47000Accuracy class AG : 2.5Response time ta : < 1sVSEVSEVSEVSEVSEAllowable pressure PS : up to 10 barInlet pressure range bpe : 0 to 10 barSet range Wh : 0.01 to 100 barFlow rate coefficient Cg : up to 14850Accuracy class AG : 2.5Response time ta : < 1s

Flanged connectionsOSE: 1” • 2” • 3” • 4” • 6” • 8” • 9” • 10”VSE: 3” • 4” • 6”

Flange ratingANSI 150, 300, 600

TemperatureStandard: -30°C +71°C

ConfigurationEasy manual resetInternal bypass 1” to 6”Top entry (easy maintenance)Shock and vibration resistantPosition indicatorLow TemperatureWater-tightPre-arrangement for remote alarms and control

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Type OSE

OSE-VSE Series

Page 41: Natural Gas Solutions

42

C

Slam shut release relaySlam shut release relaySlam shut release relaySlam shut release relaySlam shut release relaymanual resetmanual resetmanual resetmanual resetmanual reset

VSX2 Series

Type VSX2

TypesVSX2LPVSX2LPVSX2LPVSX2LPVSX2LP : low pressure version with large diaphragm, non-

balanced plugVSX2HPVSX2HPVSX2HPVSX2HPVSX2HP : high pressure version with reduced diaphragm,

balanced plug version

Technical specificationsOverpressure set range VSX2LPVSX2LPVSX2LPVSX2LPVSX2LP Who : 0.03 to 1.6 bar

VSX2HPVSX2HPVSX2HPVSX2HPVSX2HP Who : 1.1 to 5.5 barUnderpressure set range VSX2LPVSX2LPVSX2LPVSX2LPVSX2LP Whu : 0.05 to 0.75 bar

VSX2HPVSX2HPVSX2HPVSX2HPVSX2HP Whu : 0.5 to 2.8 barAccuracy class AG : 10Response time ta : < 1s

ConnectionsExternal sensing line : ¼” NPT

TemperatureStandard : -30°C +71°C

ConfigurationIntegral and automatic bypassInterchangeableManual resetLow Temperature

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 42: Natural Gas Solutions

43

C

Technical specificationsBody allowable pressure PS : 16 barPermissible inlet pressure Pe,max : up to 14 barInlet pressure range bpe : 0 to 14 barOverpressure set range Who : 0.025 to 5 barUnderpressure set range Whu : 0.007 to 2.5 barAccuracy class AG : up to ± 5%Response time ta : ≤ 1 sec.Flow rate coefficient Cg : up to 1300

Orifice Size11/16” • 1” • 1 3/16”

ConnectionsThreaded: 1½” • 2” BSPFlanged: 1½” • 2” PN 16 UNI/DIN

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Disc slam shut valveDisc slam shut valveDisc slam shut valveDisc slam shut valveDisc slam shut valvemanual resetmanual resetmanual resetmanual resetmanual reset

BM7 Series

BM7/

BM7-FS

Page 43: Natural Gas Solutions

44

C

TypesVS-FLVS-FLVS-FLVS-FLVS-FL : for middle and high pressure applicationsVS-FL-BPVS-FL-BPVS-FL-BPVS-FL-BPVS-FL-BP : for low and middle pressure applications

Construction featuresAxial flowCounterbalanced valve

Technical specificationsAllowable pressure PS : up to 100 barSet range Wh : 1 to 80 barAccuracy class AG : up to ± 1%Flow rate coefficient Cg : up to 17500

Size1” • 1½” • 2” • 2½” • 3” • 4” • 6”

Flanged connectionsSame inlet and outlet1” • 1½” • 2” • 2½” • 3” • 4” • 6”

Flange ratingPN 16, 25 UNI/DINANSI 150, 300, 600

TemperatureStandard version: working -10 °C +60 °C

ambient -20 °C +80 °CLow-temperature version: working -20 °C +60 °C

ambient -30 °C +80 °C

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)Sour gases (NACE standards)

Pilot-operated relief valvePilot-operated relief valvePilot-operated relief valvePilot-operated relief valvePilot-operated relief valve

VS-FL Series

VS-FL-BP with PRX/ 182

Page 44: Natural Gas Solutions

45

D

V/50

V/20-2

Spring-loaded relief valveSpring-loaded relief valveSpring-loaded relief valveSpring-loaded relief valveSpring-loaded relief valve

V Series

V/60

TypesV/50 V/50 V/50 V/50 V/50 and V/60V/60V/60V/60V/60 : for very low pressure applicationsV/51 V/51 V/51 V/51 V/51 and V/61V/61V/61V/61V/61 : for low pressure applicationsV/52 V/52 V/52 V/52 V/52 and V/62V/62V/62V/62V/62 : for middle pressure applications

Technical specificationsAllowable pressure V/50PS : 4 bar

V/60 PS : 2.5 barSet range Wh : 0.025 to 2 bar

Orifice size1¼” • 1½”

Threaded connectionsDifferent inlet and outlet 1”x 1½” • 1½”x 2” BSP

TemperatureWorking: -20 °C +60 °CAmbient: -30 °C +80 °C

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen ...)

V/20-2 ModelTechnical specificationsAllowable pressure PS : 100 barSet range Wh : 1.5 to 40 bar

Orifice size1”

Threaded connectionsInlet and outlet 1” NPT

TemperatureWorking -20 °C +60 °CAmbient -30 °C +80 °C

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 45: Natural Gas Solutions

46

E

TQVP-MR/

Floating ball valveFloating ball valveFloating ball valveFloating ball valveFloating ball valve

TQ Series

TQFB/

TypesTQFBTQFBTQFBTQFBTQFB : full bore lever operatedTQFB-MRTQFB-MRTQFB-MRTQFB-MRTQFB-MR : full bore gear operatedTQVPTQVPTQVPTQVPTQVP : reduced bore lever operatedTQVP-MRTQVP-MRTQVP-MRTQVP-MRTQVP-MR : reduced bore gear operated

Construction featuresSteel bodyHard-facing floating ballPTFE gaskets

Technical specificationsAllowable pressure PS : up to 100 barPermissible inlet pressure Pe,max : 100 bar

Size1” • 1½” • 2” • 2½” • 3” • 4” • 6” • 8” • 10”

Flanged connections1” • 1½” • 2” • 2½” • 3” • 4” • 6” • 8” • 10”

Flange ratingANSI 150, 300, 600

TemperatureWorking: -20 °C +60 °CAmbient: -30 °C +80 °C

ConfigurationsElectrical actuatorPneumatic actuatorManhole installationUnderground installationFIRE-SAFE version

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)Sour gases (NACE standards)Clean fluids

Page 46: Natural Gas Solutions

47

ETMFB-MR/

TMVP/

TTTTTrrrrrunniunniunniunniunniooooon ball vn ball vn ball vn ball vn ball valalalalalvvvvveeeee

TM SeriesTypesTMFBTMFBTMFBTMFBTMFB : full bore lever operatedTMFB-MRTMFB-MRTMFB-MRTMFB-MRTMFB-MR : full bore gear operatedTMVPTMVPTMVPTMVPTMVP : reduced bore lever operatedTMVP-MRTMVP-MRTMVP-MRTMVP-MRTMVP-MR : reduced bore gear operated

Construction featuresSteel bodyHard-facing trunnion ballPTFE gaskets

Technical specificationsAllowable pressure PS : up to 100 barPermissible inlet pressure Pe,max : 100 bar

Size2” • 3” • 4” • 6” • 8” • 10” • 12”

Flanged connections2” • 3” • 4” • 6” • 8” • 10” • 12”

Flange ratingANSI 150, 300, 600

TemperatureWorking: -20 °C +60 °CAmbient: -30 °C +80 °C

ConfigurationsElectrical actuatorPneumatic actuatorManhole installationUnderground installationFIRE-SAFE version

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)Sour gases (NACE standards)Clean fluids

Page 47: Natural Gas Solutions

48

E

BBBBBuuuuutttttttttteeeeerrrrrfly vfly vfly vfly vfly valalalalalvvvvveeeeesssssoooooffffft st st st st seeeeealalalalaled bodyed bodyed bodyed bodyed body

VFA Series

VFA-MR/

VFA/

TypesVFVFVFVFVFAAAAA : lever operatedVFVFVFVFVFA-MRA-MRA-MRA-MRA-MR : gear operatedVFVFVFVFVFA-MRA-MRA-MRA-MRA-MROOOOO : gear operated for use with absorbing odorizer

Construction featuresSteel butterfly valveSoft seal in the bodyReplaceable soft sealHard-facing butterfly

Technical specificationsAllowable pressure PS : up to 19 barPermissible inlet pressure Pe,max : 19 bar

Size2” • 2½” • 3” • 4” • 5” • 6” • 8” • 10”• 12”• 14”

Flanged connections2” • 2½” • 3” • 4” • 5” • 6” • 8” • 10”• 12”• 14”

Flange ratingPN16 UNI/DINANSI 150

TemperatureStandard version: working -10 °C +100 °C

ambient -20 °C +100 °CLow-temperature version: working -20 °C +100 °C

ambient -30 °C +100 °C

ConfigurationsWithout counter-flangesWith counter-flangesPneumatic controlElectric controlManhole installationUnderground installation

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)Clean fluids

Page 48: Natural Gas Solutions

49

F

TTTTTuuuuube bunbe bunbe bunbe bunbe bundldldldldle he he he he heeeeeaaaaat ext ext ext ext exccccchhhhhananananangggggeeeeerrrrrsssss

CN-CF SeriesSV Series

CF

Technical specificationsNatural (CN series) or forced (CF series) circulating water heating fluidSV/ Series steam heating fluidHeat capacity: 60 to 3140 MJ/h (14500 to 750000 kcal/h)Gas maximum allowable pressure PS : 90 barWater/steam maximum allowable pressure PS : 5 bar

Flanged connections1” • 1½” • 2” • 3” • 4” • 5” • 6” • 8” • 10” • 12” • 14”

Flange ratingGas side: ANSI 600Water/steam side: PN 6 UNI/DIN

TemperatureStandard version: working -10 °C +100 °C

ambient -20 °C +100 °CLow-temperature version: working -20 °C +100 °C

ambient -30 °C +100 °C

ConfigurationsDrain valveWater/steam side safety valve

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

CN

Page 49: Natural Gas Solutions

50

G

HHHHHigh pigh pigh pigh pigh prrrrreeeeessssssursursursursure ce ce ce ce cararararartritritritritridddddggggge fie fie fie fie filtltltltlteeeeerrrrr

FA Series

FA/11

FA/12

TypesFFFFFA 11A 11A 11A 11A 11: for pressures up to 17 barFFFFFA 12A 12A 12A 12A 12: for pressures up to 90 bar

Technical specificationsMaximum allowable pressure PS : up to 90 barFiltering surface : 0.125 to 8.4 m2

Filtering capacity : 5 µm at 98 %

Flanged connections2” • 2½” • 3” • 4” • 6” • 8” • 10” • 12” • 14” • 16”

Flange ratingPN16 UNI/DINANSI 150, 300, 600

TemperatureStandard version: working -10 °C +100 °C

ambient -20 °C +100 °CLow-temperature version: working -20 °C +100 °C

ambient -30 °C +100 °C

ConfigurationsBlind flange closureQuick closureClosure flange lifting systemDrain valveLocal clogging indicatorRemote clogging indicator

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 50: Natural Gas Solutions

51

G

LLLLLooooow pw pw pw pw prrrrreeeeessssssursursursursure ce ce ce ce cararararartritritritritridddddggggge fie fie fie fie filtltltltlteeeeerrrrr

FAG Series

FAG-A/

FAG/

TypesFFFFFAAAAAGGGGG and FFFFFAAAAAG-APG-APG-APG-APG-AP : Inlet and outlet at right-angle

connectionFFFFFAAAAAG-AG-AG-AG-AG-A and FFFFFAAAAAG-A-APG-A-APG-A-APG-A-APG-A-AP : Inlet and outlet at axial connection

Technical specificationsMaximum allowable pressure PS : up to 19 barFiltering surface : 0.06 to 4.20 m2

Filtering capacity : 5 µm at 98%

Flanged connections1” • 1½” • 2” • 2½” • 3” • 4” • 5” • 6” • 8” • 10” • 12”

Flange ratingPN16 UNI/DINANSI 150

TemperatureWorking -20 °C +60 °CAmbient -30 °C +80 °C

ConfigurationsDrain valveLocal clogging indicatorRemote clogging indicator

ApplicationsNon-corrosive gases (natural gas, compressed air, nitrogen, ...)

Page 51: Natural Gas Solutions

52

G

LLLLLooooow pw pw pw pw prrrrreeeeessssssursursursursure ce ce ce ce cararararartritritritritridddddggggge fie fie fie fie filtltltltlteeeeerrrrr

Filter 160 m3/h

Filter 160 m3/h in skid

Filter 160 m3/h

Types160 m160 m160 m160 m160 m33333/h/h/h/h/h : Compact design, excellent filtration

with low pressure differential drop

Technical specificationsMaximum allowable pressure PS : up to 4 barFiltering capacity : 160 m3

Filtering performance : 5 µm

Flanged connections1”

Temperature-20 °C +60 °C

ApplicationsNon-corrosive gases (natural gas,compressed air, nitrogen, ...)

Page 52: Natural Gas Solutions

53

H

Injection odorizing systemInjection odorizing systemInjection odorizing systemInjection odorizing systemInjection odorizing system

DosaodorConfigurationsDifferent solutions with:Control devicesOperating or stand-by pumpsVolume of injectable liquid

Pneumatic specificationsPermissible inlet pressure : 12 barOdorizable gas capacity : up to 300.000 Stm3/hOdorant injecting capacity : up to 3 l/h

Electrical specificationsControl unit provided with:- microprocessor- keyboard- display- printerPower supply : 230 V 50 HzApplication class : II B T4Interface for dialogue with remote control installations

InstallationElectronic control unit:- Wall-mounted, in safe areaPneumatic panel:- Wall-mounted, in hazardous area

Flow rate signalFlow rate signal processing for proportional dosing:- LF impulse signal- 4.20 mA analog signal

On requestHigher permissible inlet pressureFlow rate signal processing by means of calibrated orificesFlow rate signal processing from other metering systems

Software to tele-reading Dosaodor Dosalink

Functions:This software allows storage ofhistorical data from thememory of the DOSAODOR.Connection to the instrumentsand collecting the data is possibleby serial port or by modem(standard or GSM)

The software includes:- Automatic calling to system- Multi-languages

(Italian, English, French...)- Show and print data with

graphics and table- Generate data files- Exportation data in Excel / Access

format

Page 53: Natural Gas Solutions

54

H

ConfigurationsDifferent solutions with:Operating or stand-by injectorsVolume of injectable liquid

Pneumatic specificationsMax working pressure : supply 100 bar

injection up to 60 barOdorizable gas capacity : up to 1400000 Stm3/hOdorant injecting capacity : up to 14 lt/h

Electrical specificationsControl unit provided with: - microprocessor - keyboard - display - printerPower supply : 230 V 50 Hz, 115 V 60 Hz,

+/- 15% 12V DCsolar panelother on request

InstallationElectronic control unit: - Wall-mounted, in safe area - Wall-mounted, in hazardous area (EEx-d)Pneumatic panel: - Wall-mounted, in hazardous area

On request- Processing of the gas flow rate signal through the

application of particular systems and equations- Telemetering- Explosion proof EEx-d for installation of electronic

control unit in hazardous area- Version for USA and Canadian Standards

Software to tele-readingDosaodor Dosalink

Functions:This software allows storage of historical data fromthe memory of the DOSAODOR.Connection to the instruments and collectingthe data is possible by serial port or by modem(standard or GSM)

The software includes:- Automatic calling to system- Multi-languages (Italian, English, French...)- Show and print data with graphics and table- Generate data files- Exportation data in Excel / Access format

Injection odorizing systemInjection odorizing systemInjection odorizing systemInjection odorizing systemInjection odorizing system

Dosaodor-D

Page 54: Natural Gas Solutions

55

H

TypesOL-24OL-24OL-24OL-24OL-24 : volume 24 lOL-50OL-50OL-50OL-50OL-50 : volume 50 lOL-100OL-100OL-100OL-100OL-100 : volume 100 lOL-250OL-250OL-250OL-250OL-250 : volume 250 l

Absorption-type odorizing systems are employed in small- andmiddle-sized stations with flow rates up to 5000 Stm3/h.However, they are used as stand-by and emergency systems in allinjection-type odorizing installations. For the proper operation it isnecessary to reach a differential pressure, preferably by means of aVFA-MRO valve.

Construction featuresMaximum allowable pressure PS : 90 barDirect reading level gaugeRegulating, shut-off and filling valves

ConfigurationsTank and valves : carbon steelTank and valves : stainless steelMagnetic level indicator suitable for remote control

Absorption odorizing systemAbsorption odorizing systemAbsorption odorizing systemAbsorption odorizing systemAbsorption odorizing system

OL Series

Page 55: Natural Gas Solutions

56

H

TypesThe Gas Conditioning Unit is required to avoid leakage through thejoints of the pipes when a gas distribution network changes frommanufactured gas to natural gas. It injects water and/or solventsteam into the natural gas flowing through the main pipes tomaintain the pipe joints at the same volume as if manufactured gaswas still flowing through the network.

Construction featuresRegulator type B or K1000PumpWater filterSolvent tankWater tank

Vaporizing unit

Technical specificationsGas inlet pressure bpe : 1 barHeater kW : 9 to 15Water filter µ: 100Pump V: 24

TemperatureHeater : 250 °C

Injection gas conditioning systemInjection gas conditioning systemInjection gas conditioning systemInjection gas conditioning systemInjection gas conditioning system

Gas Conditioning Unit

Gas conditioning unitGas conditioning water

and softener tanks

Gas conditioning vaporizor

Gas conditioning regulatorand filter for carrier gas

Page 56: Natural Gas Solutions

57

I

Pressure RecorderPressure RecorderPressure RecorderPressure RecorderPressure Recorder

Models2000 series2000 series2000 series2000 series2000 series : recording on continuous tape chart1000 - 4000 series1000 - 4000 series1000 - 4000 series1000 - 4000 series1000 - 4000 series : recording on circular chartPR seriesPR seriesPR seriesPR seriesPR series : recording on rectangular chart

wrapped up drum

Common technical features- For pressure from 1 bar to 400 bar, measurement is effected

by means of a spiral ring Bourdon manometric element,manufactured in stainless steel AISI 316.

- For pressure from 40 mbar to 600 mbar measurement iseffected by means of manometric bellows manufactured inbronze.

- Connections: 1/2” NPTF (for PR series: 1/4”GASM).- Accuracy: superior to ± 1%.- Clockwork available on mechanical version, electrical version

220Vcc (110V), quartz version with a special 1,5 Vcc intrinsicallysafe battery pack (CESI CERTIFICATE EX - 97 D.083).

- Tape chart recording speed; 2 or 20 mm;rotation for circular chart; 1-24-48-168 h;rotations for rectangular charts 24-48 h or daily/weekly.

- Case: by IP54 die-casting aluminium; painted with epossidicpowders.

On request- More records in the same case (at least 3 scale ranges).- Chart speeds or rotations on requests.

1000 Series

PR Series

Page 57: Natural Gas Solutions

58

I

Pressure and temperature recorderPressure and temperature recorderPressure and temperature recorderPressure and temperature recorderPressure and temperature recorder

Models2000 series2000 series2000 series2000 series2000 series : recording on continuos tape chart1000 - 4000 series1000 - 4000 series1000 - 4000 series1000 - 4000 series1000 - 4000 series : recording on circular chart

Technical featuresPressure- For pressure from 1 bar to 400 bar, measurement is effected by

means of a spiral ring Bourdon manometric element,manufactured in stainless steel AISI 316.

- For pressure from 400 mbar to 600 mbar measurement iseffected by means of manometric bellows manufacted inbronze.

- Connections: 1/2” NPTF.- Accuracy: superior to ± 1%.Temperature- Mercury expansion or inert gas thermometric element,

manufactured in carbon steel or stainless steel.- Thermometric element length: 2-5-10-15-20-25-30 m, besides

5 m adjustment accurs at ambient temperature.- Range scale -10/+40°C, -20/+60°C, -20/+80°C, 0-100°C.- Process connections through threaded thermo-element 3/4”

NPTM, 1” NPTM or flanged.- Accuracy: better than ± 1%.

Common technical features- Clockwork available on a mechanical version, electrical version

220Vcc (110V), quartz version with a special 1,5 Vcc intrinsicallysafe battery pack (CESI CERTIFICATE EX-97.D.083).

- Tape chart recording speed: 2 or 20 mm;rotation for circular chart: 1-24-48-168 h

- Case: by IP54 die-casting aluminium; paintedwith epossidic powders.

On request- Additional records in the same case

(at least 3 scale ranges).- Element termometric on request temperature

range scale and length.- Chart speeds or rotations on request.

2000 Series

Page 58: Natural Gas Solutions

59

I

Flow rateFlow rateFlow rateFlow rateFlow ratePrPrPrPrPreeeeessssssursursursursure-Te-Te-Te-Te-Teeeeemmmmmpppppeeeeerrrrraaaaatttttururururure re re re re recececececooooordrdrdrdrdeeeeerrrrr

Models2000 series2000 series2000 series2000 series2000 series : recording on continuos tape chart1000 series1000 series1000 series1000 series1000 series : recording on circular chart

Technical featuresFlowrate- Mercury differential tanks mausurement element- Range scale: 0-100, 0-200, 0-500 mbar- Pressure range: ANSI 150-300-600-900- Accuracy: superior to ± 1%.- Connection: 1/2” NPTF.Pressure- For pressure from 1 bar to 400 bar, measurement is effected by

means of a spiral ring Bourdon manometric element,manufactured in stainless steel AISI 316

- For pressure from 40 mbar to 600 mbar measurement iseffected by means of manometric bellows manufacted inbronze.

- Connections: 1/2” NPTF.- Accuracy: superior to ± 1%.Temperature- Mercury expansion or inert gas thermometric element,

manufactured in carbon steel or stainless steel.- Thermometric element length: 2-5-10-20-25-30 mt., besides

5m. The adjustment occurs at ambient temperature.- Range scale -10/+40°C, -20/+60°C, -20/+80°C, 0-100°C.- Process connections through threaded thermo-element

3/4” NPTM, 1” NPTM or flanged.- Accuracy: superior to ± 1%.

Common technical features- Clockwork available on a mechanical version, electrical version

220Vcc (110V), quartz version with a special 1,5 Vcc battery, atintrinsically safe feeder (CESI certificate EX-97.D.083).

- Tape chart recording speed: 2 or 20 mm;rotation for circular chart; 1-24-48-168 h

- Case: by IP54,die-casting aluminium; painted with epossidicpowders.

On request- Element thermometric on request temperature

range scale and length.- Chart speeds or rotations on request.

Triplex

2000 Series

Page 59: Natural Gas Solutions

60

I

Flow computerFlow computerFlow computerFlow computerFlow computerFlow rate and energy measurementFlow rate and energy measurementFlow rate and energy measurementFlow rate and energy measurementFlow rate and energy measurement

TypesFlowti - T502Flowti - T502Flowti - T502Flowti - T502Flowti - T502 : for turbine meteringFlowti - T504Flowti - T504Flowti - T504Flowti - T504Flowti - T504 : single-channel or double-channel for orifice

metering

ConfigurationsIt’s modular construction enables a complete range of solutions withmodem, printer, adjustment and recording of quantities, connectionsto remote controls.Access to programming and data is protected from any tamperingactions.

Electrical specificationsPower supply : 110/230 V 50 Hz

(solar panel)With integrated emergency device : 12/24 V DCSignal protection through intrinsic safety technology [EEx ia]Working temperature : -20 °C +50 °CAvailability of opto-insulated 4-20 mA analog outputs and relay digitaloutputs.

Correction equationsGas compressibility : AGA NX19 mod., AGA 8, GERG 88Volume metering : AGA 7Orifice metering : CNR-UNI 10023 / ISO 5167

Inlet signalsPressure : 4-20 mADifferential pressure : 4-20 mACarbon dioxide CO2 : 4-20 mA/keyboardNitrogen N2 : 4-20 mA/keyboardDensity : 4-20 mA/ frequency/gaz

analizer/keyboardSet-Point : 4-20 mA/keyboardVolume : High/Low frequencyTemperature : PT 100 4 conductors

Software to telereading Flow Computers andCorrectors TELETI WIN-PLUS

Functions:This software allows storage of historical data fromthe memory of the flow computer/corrector FLOWTI series.

Connection to the instruments and collecting the data is possible byserial port or by modem (standard or GSM)

The software includes:- Automatic calling to system- Multi-languages

(Italian, English, French...)- Show and print data with

graphics and table- Generate data files- Exportation data in Excel /

Access format

Flowti Computer

Page 60: Natural Gas Solutions

61

I

Flow corrector volumetric flow rateFlow corrector volumetric flow rateFlow corrector volumetric flow rateFlow corrector volumetric flow rateFlow corrector volumetric flow ratemmmmmeeeeeasurasurasurasurasureeeeemmmmmeeeeennnnnt int int int int intrinsitrinsitrinsitrinsitrinsic sc sc sc sc safafafafafeeeeettttty EEx iy EEx iy EEx iy EEx iy EEx iaaaaa

Flowti CorrectorTypesFlowti - T600TZFlowti - T600TZFlowti - T600TZFlowti - T600TZFlowti - T600TZ : with temperature sensorFlowti - T600PTZFlowti - T600PTZFlowti - T600PTZFlowti - T600PTZFlowti - T600PTZ : with pressure and temperature sensorsFlowti - T600MTLFlowti - T600MTLFlowti - T600MTLFlowti - T600MTLFlowti - T600MTL : with pressure and temperature sensorsFlowti - T600MAFlowti - T600MAFlowti - T600MAFlowti - T600MAFlowti - T600MA : with pressure and temperature sensorsFlowti - T600.XFlowti - T600.XFlowti - T600.XFlowti - T600.XFlowti - T600.X : special configurations

ConfigurationsIntegrated pressure transmitters, relative or absolute versions from1.6 bar to 80 barLow frequency volume signalHigh frequency on request for power supplied modelsBattery power supply (TZ-PTZ)Power supply and integrated signal repeater (MA)Modem and integrated signal repeater for remote reading (MTL)Serial repeater with PC interfaceAnalog output

General specificationsIP 55 plastic enclosureLCD Display (2x20)Membrame keyboardProtected data accessData storage and transmission via serial port or dial-up modem orGSM Storage data for 60 days ( volume, pressure, temperature)

Electrical specificationsEEx i battery power supply : alkalin battery for 2 working years

litium battery for 5 working yearsPower supply : 230 V 50 HzIntegrated emergency deviceBuilt-in compliance with EEx ia II B T3 intrinsic safetyWorking temperature : -20 °C +60 °CRS-232 serial output [EEx ia]Volume impulse outputs [EEx ia]

Correction equationsGas compressibility : AGA NX19 mod., AGA 8, GERG 88Volume metering : AGA 7Orifice metering : CNR-UNI 10023 / ISO 5167Others upon request

Flowti-T600.XSpecial configuration for the calculation and storage of flow rate,volumes, thermal energy suitable for liquids and gases.Two analog inputs to be selected among pressures and temperatures.One analog inlet to be selected between 4-20 mA and resistive signal.One impulse signal to be selected between low and high frequency.

Software to telereading Flow Computers andCorrectors TELETI WIN-PLUSFunctions:This software allows storage of historical data from the memory ofthe flow computer/corrector FLOWTI series.Connection to the instruments and collecting the data is possible byserial port or by modem (standard or GSM)The software includes:- Automatic calling to system- Multi-languages (Italian, English, French...)- Show and print data with graphics

and table- Generate data files- Exportation data in Excel / Access format

Page 61: Natural Gas Solutions

62

I

Data logger multifunctional computer/loggerData logger multifunctional computer/loggerData logger multifunctional computer/loggerData logger multifunctional computer/loggerData logger multifunctional computer/loggerininininintrinsitrinsitrinsitrinsitrinsic sc sc sc sc safafafafafeeeeettttty EEx iy EEx iy EEx iy EEx iy EEx iaaaaa

Logti-T600 SeriesFunctionThe series of Logti-T600 loggers enables to store and analyze mainphysical parameters of a pressure regulating unit in gas lines.Controllable parameters:- Inlet pressure- Outlet pressure- TemperatureGas flow rate measured by:- Pulse signal from a meter- Analog signal of closing member positionAlso suitable for water lines

ConfigurationsLF inlets for volume and closing member positionTwo configurable inlets with:- one pressure- two pressures- one pressure and one temperature

General specificationsIP 55 plastic enclosureLCD Display (2x20)Membrane keyboardInstallation in hazardous areaProtected data accessData storage and transmission via serial port

Dedicated softwareWindows 3.x or later (not included)

Electrical specificationsEEx i battery power supplyIntrinsic safety in compliance with EEx ia II B T3Working temperature: -20 °C +60 °CRS-232 serial output [EEx ia]

Page 62: Natural Gas Solutions

63

I

Data logger for impulse acquisitionData logger for impulse acquisitionData logger for impulse acquisitionData logger for impulse acquisitionData logger for impulse acquisitionfrom meters or flow correctorsfrom meters or flow correctorsfrom meters or flow correctorsfrom meters or flow correctorsfrom meters or flow correctors

T-LogFunctionT-LOG is an electronic device for logging pulse volumes datagenerated from meters or flow correctors and for sending aprogrammable SMS through GSM network to the supervisor centre.T-LOG enables managing consumption data of natural gas incustomer stations.

General specifications- IP65 fibreglass enclosure- RS232 Serial port for local configuration and data collection- Integral GSM modem- SMS format/time selectable- No 2 low frequency input (counter)- No 2 fraud-proof input- No 2 alarm input- Low consumption

Electrical specifications- EEx device for installation in a safe area- Alimentation by lithium battery for 5 working years

Page 63: Natural Gas Solutions

64

I

Remote control systemRemote control systemRemote control systemRemote control systemRemote control system

LC 21 SeriesIn natural gas distribution systems it might be necessary to vary theline pressure in order to guarantee:- distribution safety- delivery to the users- flow rate balance in distribution lines.

TTTTTARARARARARTTTTTARARARARARINIINIINIINIINI has implemented a system allowing the operator tovary, either remotely or locally, the value of the regulated pressureand the maximum flow rate delivered by the station.This system allows to keep the settings in all regulating appliancesduring the commissioning of the installation.The LC 21 series Remote Control unit can control an unlimitednumber of pilots and therefore there is no limitation to the numberof regulators used. Installations using this system can utilize severalregulating lines with one or more pressure regulators each line.The system can is also applicable on existing installations.

Functional specificationsPilots pressure set range : 0.5 to 40 barMax. pressure increase : up to 20 barMin. pressure increase : up to 0.001 barIncrease/decrease speed : to be setSet point accuracy : up to ± 0.001 bar

Electrical specificationsPower supply : 230 V 50 HzMaximum absorption : 33 VAEmergency power supply : 24 hoursProtection class : IP 55Electrical protection : EEx ia/EEx d

Page 64: Natural Gas Solutions

65

J

Underground modulesUnderground modulesUnderground modulesUnderground modulesUnderground modules

MIF • MI-VP • MIC • MIR SeriesMIF SeriesThis series is composed by two models MI-F/40 and MI-F/65, employspilot-operated pressure regulators type MLF-BP and slam shut valvetype BM5.

Technical featuresPermissible inlet pressure Pe,max : 19 barDesign temperature : -20 °C + 50 °CMin. operating differential pressure : 0.3 barAccuracy class AC : up to 2.5Lock-up pressure class SG : up to 10

MI-VP SeriesThis series is composed by three models MI-VP/600,MI-VP/1000 and MI-VP/1500, employs pilot-operated pressureregulators type MLF-BP and slam shut valve type BM5.Gas inlet and outlet pipes are connected through quick couplings withconic flaring, tightness is ensured by o-ring.

Technical featuresPermissible inlet pressure Pe,max : 5 barDesign temperature : -20 °C + 50 °CMin. operating differential pressure : 0.3 barAccuracy class AC : up to 2.5Lock-up pressure class SG : up to 10

MIC SeriesThis series is composed by three models MIC/25, MIC/50 and MIC/80,employs pilot-operated pressure regulators type Cronos withregulator-monitor-slam shut functions.Inlet and outlet valves together with the regulating line system by-pass and the relief valve are placed inside the container.

Technical featuresPermissible inlet pressure Pe,max : 6 barDesign temperature : -20 °C + 50 °CMin. operating differential pressure : 0.3 barAccuracy class AC : up to 2.5Lock-up pressure class SG : up to 10

MIR SeriesThis series is composed by one model MIR/65, employs spring-loadedpressure regulators type MBN and slam shut valve type BM5.Inlet and outlet valves together with the relief valve are placed insidethe container.

Technical featuresPermissible inlet pressure Pe,max : 6 barDesign temperature : -20 °C + 50 °CMin. operating differential pressure : 0.3 barAccuracy class AC : up to 2.5Lock-up pressure class SG : up to 10

MIF Series

MI-VP Series

MIC Series

MIR Series

Page 65: Natural Gas Solutions

66

J

Underground modulesUnderground modulesUnderground modulesUnderground modulesUnderground modules

ME 2•ME 3 • ME 4•ME 5 • K1000 SeriesOur underground modules are maintenance and commissioning easy.Their large accessibility and low dept implantation facilitates alloperations.

ME 2 SeriesThe ME 2 series employs direct-operated spring set point regulatorstype REGAL 2.It can be equipped with a slam shut valve type VSX2.

Technical featuresPermissible inlet pressure Pe max : 10 barDesign temperature : -20°C to +60°CAccuracy class AC : 5 to 10Lock-up pressure class SG : 10 to 20

ME 3 SeriesThe ME 3 series employs direct-operated spring set point regulatorstype BPZ-MPZ.It can be equipped with a slam shut valve type VSX2.

Technical featuresPermissible inlet pressure Pe max : 4 barDesign temperature : -20°C to +60°CAccuracy class AC : 5 to 10Lock-up pressure class SG : 10 to 20

ME 4 SeriesThe ME 4 series employs direct-operated spring set point regulatorstype B-E.

Technical featuresPermissible inlet pressure Pe max : 5 barDesign temperature : -20°C to +60°CAccuracy class AC : 10Lock-up pressure class SG : 20

ME 5 SeriesThe ME 5 series employs direct-operated spring set point regulatorstype REGAL 3.It can be equipped with a slam shut valve type VSX2 or OS2.

Technical featuresPermissible inlet pressure Pe max : 4 to 10 barDesign temperature : -20°C to +60°CAccuracy class AC : 10Lock-up pressure class SG : 15 to 30

K1000 SeriesThis series is composed of a multi-functional pilot-operated pressureregulator. The K1000 is equipped with a slam shut valve type OS2 anda Francel Piloting System.

Technical featuresPermissible inlet pressure Pe max : 25 barDesign temperature : -20°C to +60°CMin. operating differential pressure : 0.5 barAccuracy class AC : 2.5Lock-up pressure class SG : 5

K1000 type

Large underground modules

ME 3 type

ME 4 type

ME 5 type

Page 66: Natural Gas Solutions

67 K

AAAAAfffffttttteeeeer-sr-sr-sr-sr-salalalalaleeeees ss ss ss ss seeeeerrrrrviviviviviccccceeeee

On a global scale we havewe havewe havewe havewe have, on call, a team oftechnicians for starting-up installations andcommissioning.

Our Service is available for any claim underwarranty, scheduled technical assistance,assistance on call and the supply of spare parts.

By means of the availability of back-up regulatingunits, ooooour ur ur ur ur After-Sales Service can guarantee thecontinuity of the operation of existinginstallations. The Service organization is availablefor installation extension and/or modification and/or equipment modernization.

Certification of service intervention, inaccordance to national and internationalstandards, in countries where we operate, is aguarantee of quality of the job being carried outby the After-Sales Service technicians.

Our Educational Service organizes trainingcourses as well at various levels, such as themaintenance of equipment, the knowledge ofstandards, the design of regulating installationsand the design of gas distribution lines.

Page 67: Natural Gas Solutions

68K

SpSpSpSpSpararararare Pe Pe Pe Pe Pararararartststststs

WEWEWEWEWE guarantee the availability of its equipmentspare parts by supplying complete spare part kits.

In order to satisfy the Customers requirements,our spare parts warehouse is fully automated so toassure fast deliveries.

Page 68: Natural Gas Solutions

69

QQQQQuiuiuiuiuick Seck Seck Seck Seck Selllllececececectititititiooooon Rn Rn Rn Rn Regulegulegulegulegulaaaaatttttooooor Tr Tr Tr Tr Taaaaabbbbbllllleeeee

RegulatorRegulatorRegulatorRegulatorRegulator SSSSSlllllam Sham Sham Sham Sham Shuuuuut Vt Vt Vt Vt Valalalalalvvvvveeeee PilotPilotPilotPilotPilot ConnectionsConnectionsConnectionsConnectionsConnections Pressure rangePressure rangePressure rangePressure rangePressure range Max PeMax PeMax PeMax PeMax Pe(bar)(bar)(bar)(bar)(bar) (bar)(bar)(bar)(bar)(bar)

FL Yes Yes 1” - 6” 0.5 - 80 100

FL-BP Yes Yes 1” - 6” 0.01 - 8 25

MP Yes Yes 1” - 8” 1 - 70 85

1098-EGR No Yes 1” - 6” 0.005 - 20 27

EZH Yes Yes 1” - 8” 0.5 - 80 100

CRONOS 1 / 2 Yes Yes 1” - 3” 0.5 - 80 100

MPS Yes Yes 1” - 4” 1 - 70 85

ASOFLEX Yes Yes 2” - 6” 0.01 - 16 25

EZR Yes Yes 1” - 8”x6” 0.5 - 48 72.4

K Yes Yes 2”x3” - 3”x6” 0.1 - 85 100

971 No Yes 10” 0.5 - 70 100

DRPN Yes Yes 1” 1 - 10.5 70

67 No No ¼” 0 - 8.6 17.2

1301 No No ¼” 0.69 - 34.5 414

RP/10 No No ¾” x 1” 0.5 - 30 220

RLC/20 No No 1” 20 - 250 320

MN-MF, MR Yes No 1”x2½” - 4” 0.010 - 3 20

REGAL3 Yes No 2” 0.008 - 3 10

REGAL2 Yes No 1”x1¼” - 1”x2¼” 0.008 - 0.320 10

BPZ MPZ Yes No 1” x 2¼” 0.021-0.300 4

A/100 Yes No 2” 0.010 - 0.300 20

A/140 Yes No 2” 0.010 - 0.300 20

RP Yes No 1”x1G” - 1G”x2” - 2”x3” 0.1 - 4 20

B/240 Yes No 1” 0.010 - 0.300 20

627 Yes No ¾” - 2” 0.34 - 34 100

R Yes No 1” 0.15 - 0.70 6

B No No ¾” x 1¼” 0.009 - 0.400 7

BSV No No ¾” x 1¼” 0.009 - 0.070 5

Page 69: Natural Gas Solutions

70

Regulating and Metering installationsRegulating and Metering installationsRegulating and Metering installationsRegulating and Metering installationsRegulating and Metering installationsand Final regulating installationsand Final regulating installationsand Final regulating installationsand Final regulating installationsand Final regulating installations

The long experience and professionalismacquired during the years has brought to recordamong its most impressive projects regulatingand metering installations with flow rates up to400,000 Stm3/h and with inlet pressure up to75 bar.

According to inlet pressure and customers’requirements, Emerson Natural Gas CompaniesEmerson Natural Gas CompaniesEmerson Natural Gas CompaniesEmerson Natural Gas CompaniesEmerson Natural Gas Companiesare capable of supplying the following types ofinstallation:

- gas pressure first regulating and receivinginstallation

- first-stage regulating installation forindustrial use

- intermediate regulating installation- final regulating installation for domestic use- second-stage regulating installation for

industrial use

Page 70: Natural Gas Solutions

71

Page 71: Natural Gas Solutions

72

Regulating and metering installationsRegulating and metering installationsRegulating and metering installationsRegulating and metering installationsRegulating and metering installationsand Final regulating installationsand Final regulating installationsand Final regulating installationsand Final regulating installationsand Final regulating installations

Page 72: Natural Gas Solutions

73

Page 73: Natural Gas Solutions

74

NotesNotesNotesNotesNotes

Page 74: Natural Gas Solutions

76© Francel S.A. 2003, imprimé en France par MARCOM Francel

Emerson Process ManagementEmerson Process ManagementEmerson Process ManagementEmerson Process ManagementEmerson Process ManagementRegulator DivisionRegulator DivisionRegulator DivisionRegulator DivisionRegulator DivisionFrancel S.A.Francel S.A.Francel S.A.Francel S.A.Francel S.A.Z.A. La Croix St. Mathieu28320 Gallardon - FranceTel. +33 (0)2 37 33 47 00Fax. +33 (0)2 37 31 46 56

+33 (0)2 37 90 91 48 (Export)www.francel.com

Emerson Process ManagementEmerson Process ManagementEmerson Process ManagementEmerson Process ManagementEmerson Process ManagementRegulator DivisionRegulator DivisionRegulator DivisionRegulator DivisionRegulator DivisionOOOOO.M.M.M.M.M.T.T.T.T.T. O. O. O. O. Offiffiffiffifficccccininininina Ma Ma Ma Ma Meccanieccanieccanieccanieccanica Tca Tca Tca Tca Tararararartttttarararararini Sini Sini Sini Sini S.p.p.p.p.p.A.A.A.A.A.....Via P.Fabbri, 140013 Castel Maggiore (Bologna) - ItalyTel. +39 (0)51 419 0611Fax. +39 (0)51 419 0715www.tartarini.it