National Timber Bridge Design Competition –2019
College or University Name: SUNY College of Environmental Science and Forestry
Student Chapter (ASCE or FPS): FPS
Address: 1 Forestry Dr. Syracuse, NY 13210
Website Address: www.esf.edu
Faculty Advisor: Dr. Paul Crovella
Email: [email protected]
Phone: (315) 470-6839
Student Member in Charge of Project: Elijah Meier
Email: [email protected]
Phone: (518) 821-0167
![Page 2: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/2.jpg)
Team Member Roles Class
Elijah Meier Project Manager 2019
Brad Howes Drawings & Estimating 2019
Alex McGill Construction and Testing 2019
McKenna Pason Designing & Engineering 2020
Erika Gripp Competition Submission Coordinator 2020
Hours Spent on This ProjectStudents:185Faculty:10Cost of MaterialsDonated: $0Purchased: $1,123.52
![Page 3: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/3.jpg)
Abstract (Maximum 500 Word Narrative): Explain the bridge design concept and what was done to optimize stiffness while attemp ting to minimize weight of the structure.
This bridge will be located in a client’s backyard in Jamesville NY to account for a difference in land elevation and make it easier to walk, as well as maintain the property. The team decided to keep the bridge as a simple to construct.
The construction of the bridge began with drying all wood members in the kiln then, planning and jointing the boards that would compose the glulam beam after it has reached appropriate moisture content. The two 18 foot
structural beams were then glued together, consisting of four 2x8s face to face, as well as one 2x6s on the top, and one 2x6 cut to 5 ⅝” on the bottom glued and screwed down with decking screws on both the top and bottom of the beam.
Due to the member length limit, each component of the beam was cut and glued back together using a 45 degree angle scarf joint method. Titebond 3 waterproof wood glue was used for all gluing applications.
Perpendicular to the glulam beam are thirteen joists, 5 feet long 2x12s, mounted to the face of the beams using an 18 gauge triple zinc face mount joist hanger. The joist hanger is mounted using 9-gauge hot-dipped galvanized steel common nails. These members of the bridge support the decking, which is comprised of 30 2x6s 6 feet long on face
screwed in with Primeguard Plus #10 x3 ½ in polymer deck screws.
By gluing and connecting the structural beams of the deck with screws, nails and joist hangers as well as drying all of our lumber, we were able to achieve a maximum stiffness of the bridge. The glue also enabled us to minimize the
weight of the structure significantly while still maintaining the structural integrity of the wood.
![Page 4: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/4.jpg)
1. Loading Increment 2. Bridge 3. Beam
LEFT
4. Beam
RIGHT
5. Average
(L & R)
6. Gross Deck 7. Net Deck
5 kN 0.66 2.72 2.64 2.68 3.56 0.88
10 kN 2.54 5.36 5.31 5.34 6.53 1.19
15 kN 3.39 7.67 7.72 7.70 9.32 1.62
20 kN – 0 min. 3.56 10.31 10.13 10.22 12.06 1.84
20 kN – 15 min. 3.86 10.67 10.62 10.65 12.52 1.87
20 kN – 30 min. 3.94 10.77 10.74 10.76 12.65 1.89
20 kN –45 min. 3.96 10.87 10.82 10.85 12.75 1.90
20 kN – 60 min. 4.06 10.92 10.89 10.91 12.80 1.89
1. Loading Increments2. Bridge – As measured at midspan of the longitudinal beam receiving greatest loading.3. Beam L – As measured under the longitudinal beam to left of selected deck monitoring point.4. Beam R – As measured under the longitudinal beam to right of selected deck monitoring point.5. Average (L & R) – Average of 3 and 4, above.6. Gross Deck – As measured under the loading point expected to experience maximum deflection.7. Net Deck – Column 6 minus Column 5.Deck Span:Transverse distance between main longitudinal bridge support members measured from inside edge to inside edge = ____1828.80____mm ÷ 100 = ____18.29___mm = maximum allowable net deck deflection.
2. Deflection Table (Deflection – millimeters rounded to 2 decimal places)
![Page 5: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/5.jpg)
Material Item Description Weight (kg)(28) 2x10x8 #2 Prime Treated Lumber 1.45 per ft
(15) 2x8x8 #2 Prime Treated Lumber 1.22 per ft
(8) 2x12x12 #2 Prime Treated Lumber 1.81 per ft
(25) 2x6x12 #2 Prime Treated Lumber 0.75 per ft
(5 lbs) Primeguard Plus #10 x3 ½ in Polymer Deck Screws 2.27
(5 lbs) 3 in 9-Gauge Hot-Dipped Galvanized Steel Common Nails 2.04
(26) 2x10 18-Gauge Triple Zinc Face Mount Joist Hanger 4.68
(3) 8 ft Anti-Slip Tape 0.23
(16 fluid oz) Brown Interior/Exterior Wood Adhesive 3.79
(128 fluid oz) Brown Interior/Exterior Wood Adhesive 1.90
TOTAL WEIGHT (Kg) 616.61
Weight Non-Wood (Kg) 13.32
Percent Non-Wood (max. 25%) 2.16%
3. Materials List
![Page 6: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/6.jpg)
4. Summary – Describe Bridge and Its Behavior Under Load (max. 500 words)
Through our design calculations, we predicted the deflection of the bridge to be near the competition requirements of 18.29 mm. Our bridge actually had an our greatest deflection of 4.27 mm which is acceptable under our total span. Our bridge is too large to fit under our testing machine, so we tested using increments of 70 lb sandbags. The bridge seemed very stiff during the loading of
each increment of sand bags, with no visible by the eye deflection. Our team heard a few quiet creaking noises but we suspected it was the base of our loading set up to hold the sandbags in place,
which was composed of some large wood members that totalled 280 lbs. accounted for when starting the first increment of the loading test. The decking, joists and beams all had minimal
deflection even with the 20 KN load on for an hour. Our team is pleased and impressed with how our bridge performed during the load testing.
![Page 7: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/7.jpg)
Side Drawing (insert below)
![Page 8: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/8.jpg)
End Drawing (insert below)
End Drawing (insert below)
![Page 9: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/9.jpg)
Trimetric Drawing (insert below)
![Page 10: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/10.jpg)
Drawing Clearly Showing Location of Loading and Deflection Gage Points in Relation to Longitudinal Members (insert below)
NOTE: Repeat slide if loading set-up was moved to measure deck deflection.
![Page 11: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/11.jpg)
Drawing Clearly Showing Location of Loading and Deflection Gage Points in Relation to Transverse Members (insert below)
NOTE: Repeat slide if loading set-up was moved to measure deck deflection.
![Page 12: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/12.jpg)
PHOTO Showing SIDE View of Loading Setup #1 for Measuring Bridge Deflection (insert below)
![Page 13: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/13.jpg)
PHOTO Showing END View of Loading Setup #1 for Measuring Bridge Deflection (insert below)
![Page 14: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/14.jpg)
PHOTO Showing SIDE View of Loading Setup #2 for Measuring Bridge Deflection (insert below)
NOTE: Repeat slide if loading setup was moved to measure deck deflection.
![Page 15: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/15.jpg)
PHOTO Showing END View of Loading Setup #2 for Measuring Bridge Deflection (insert below)
NOTE: Repeat slide if loading set-up was moved to measure deck deflection.
![Page 16: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/16.jpg)
End Photo of Finished Bridge
![Page 17: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/17.jpg)
Side Photo of Finished Bridge
![Page 18: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/18.jpg)
Trimetric Photo of Finished Bridge
![Page 19: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/19.jpg)
Team Photo (with bridge in the foreground, where possible)
![Page 20: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/20.jpg)
Briefly describe each bridge component, as applicable.
Joists Thirteen 2x12 by 5’ long
Decking 2x6 by 6’ long boards running parallel to the span
Floor Beams Two 18’ 12.25”x5.5” Glulam Beams composed of 4 wide 2x10s on edge and 1 2x6 on face on top and bottom
Suspension No suspension
Unique Components Creating a Glulam Beam and using 2x12 joist hangers to hold secondary members
6. Bridge Component Details
![Page 21: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/21.jpg)
7. Preservative Treatment: Describe the preservative treatment applied to all wood members. Include type and concentrations. Also, include a short statement of why this
treatment was selected. Did the treatment requirement present any special problems? If yes, provide details. If treatment was not selected, explain why.
All wood members were treated with chromium copper azole type C by Lowes to protect all pieces from the elements. This treatment was selected to account for the direct
ground to wood contact, as well as the permanent outdoor use of the bridge. The treatment was applied before purchase and did not present any special problems. The
team also selected Primeguard Plus polymer deck screws, as well as hot-dipped galvanized steel common nails to fasten certain bridge members together. By choosing
these treated fasteners, the team is ensuring the bridge can withstand weathering without rusting or other moisture related issues resulting from the connections. The treatment left the members with a higher moisture content than normal, where we
needed a low moisture content in some members because of our use of glue needing a dry clean wood.
![Page 22: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/22.jpg)
8. Special Considerations –Indicate the End Use of Your Bridge
Our client would like this bridge on his property in Jamesville NY to span across an 18 foot gap caused by a difference in land
elevation on his property, as well as to add to an aesthetic backyard landscape. More specifically, he wants the bridge to
make it easier to get from one side to the other for not only himself, but also his grandchildren. Thus, Non-Slip grip tape will be added after installation of bridge. The bridge will mainly be used for light foot traffic, but it is also designed to hold various lawn care equipment, such as a a ride-on lawn mower and a
snow blower.
![Page 23: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/23.jpg)
Final Bridge Placement Jamesville, New York
![Page 24: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/24.jpg)
9. Summarize the Team’s Experience from Participation in this Competition. Was it beneficial? What steps would you
recommend to improve the experience?
Overall, we found this competition to be a great experience to learn the real applications of seeing a project from start to finish, as well as hands on
construction involvement. We found the freedom of design to be very beneficial because it allowed our team to create a bridge that will best benefit the owner, as well as meet the competition requirements and our inexperience in woodworking.
The most difficult requirements for our team to meet was the maximum member length of 2.1 meters. We did not want any of our joints to line up to avoid stiffness issues, but it was very difficult to achieve that with the maximum member length
causing there to be many joints on our bridge.
Also since these bridges are almost always used in a real life application after the competition, the member length can be very difficult and restraining for the design
as a whole.
![Page 25: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/25.jpg)
Photo of Bridge Weighing
![Page 26: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/26.jpg)
One photo of each deflection gauge at full loading, with identification sign indicating DECK, BEAM LEFT, BEAM RIGHT, BRIDGE.
20 kN Bridge Deflection gauges (Test #1) - 60 mins
Bridge Beam Right Deck Beam Left
![Page 27: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/27.jpg)
One photo of each deflection gauge at full loading, with identification sign indicating DECK, BEAM LEFT, BEAM RIGHT, BRIDGE.
20 kN Deck Deflection gauges (Test #2) - 60 mins
Bridge Beam Right Deck Beam Left
![Page 28: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/28.jpg)
Add as many photos as you wish showing the bridge construction process. Especially consider photos of internal structural components that may not be visible to judges from observing the
finished bridge.
![Page 29: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/29.jpg)
Add as many photos as you wish showing the bridge construction process. Especially consider photos of internal structural components that may not be visible to judges from observing the
finished bridge.
![Page 30: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/30.jpg)
![Page 31: National Timber Bridge Design Competition 2019southwest.msrcd.org/Timberbridge/PPT/SUNY3 - 2019.pdfThrough our design calculations, we predicted the deflection of the bridge to be](https://reader030.fdocuments.us/reader030/viewer/2022040213/5ea6c609a3205b46545f9686/html5/thumbnails/31.jpg)