NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o....

47
Sl.N o. Description of Work Unit Block- A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs. 1 SCAFFOLDING SCAFFOLDING: All the areas which are under consideration for the repair & rehabilitation are to be provided with double scaffolding independent of the work having two sets of vertical supports. The supports shall be sound and strong, tied together with horizontal pipes over which scaffolding planks shall be fixed. Supply and fixing of scaffolding with bracing including cost of all material, all labour charges etc., complete to the entire height of the building. The pipes are of C class 40mm dia with required working platform of 40mm thick wooden planks of width not less than 300mm, with hand rails for the safety measures. (Same Scaffolding to be used for Rehabilitation, Renovation, Electrical, Plumbing and Painting works) Sqm 1290 1290 1290 3870 REHABILITATION WORK FOR NABARD STAFF QUARTERS, BAZULLAH ROAD AT T.NAGAR, CHENNAI - 600 017. CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47

Transcript of NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o....

Page 1: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.1 SCAFFOLDING

SCAFFOLDING: All the areas which are under consideration for therepair & rehabilitation are to be provided with double scaffoldingindependent of the work having two sets of vertical supports. Thesupports shall be sound and strong, tied together with horizontalpipes over which scaffolding planks shall be fixed. Supply and fixing of scaffolding with bracing including cost of all material, all labourcharges etc., complete to the entire height of the building. The pipesare of C class 40mm dia with required working platform of 40mmthick wooden planks of width not less than 300mm, with hand railsfor the safety measures. (Same Scaffolding to be used forRehabilitation, Renovation, Electrical, Plumbing and Paintingworks)

Sqm 1290 1290 1290 3870

REHABILITATION WORK FOR NABARD STAFF QUARTERS, BAZULLAH ROAD AT T.NAGAR, CHENNAI - 600 017.

CIVIL WORKS BOQ

BLOCK - A,B&C

                                                                      1 of 47                                                                            

Page 2: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.2 SUNSHADEa DISMANTLING

DISMANTLING :-Mark the outer perimeter of the balcony areawhich are to be demolished. Provide required safety arrangementslike barricading the area right below with isolated tape. Break theconcrete using an electrically operated chipping machine withoutcreating much of sound and vibration to the nearby areas. Thechipping should be done to the edge of the cantilever beam also.Placing the handrails in position with required arrangements likewelding, etc..Stacking of steel bars if any and disposal ofunserviceable material woutside the premises to a distance as per theinstructions of the Engineer in Charge.

Cum 3 3 3 9

b ANCHORING

ANCHORING :Mark the position of holes to be drilled foranchoring the rebar into the lintel beam/beam. Drill 12mm dia holesin the marked places using rotary hammer drilling machine ofreputed make to a depth of 100mm into the lintel beam/beam. Cleanthe holes neatly and wash the same with jet of water. Allow it to dryand make sure that no fine dust particles are present in the holes.Mix the base and hardener of the polyester resin using a spatula andpush the same in to the holes with a proper tool so that the bottommost point of the hole receives the material. The filling is to be donefor a minimum portion of 1/3rd of the hole depth. Now insert therebar which need to be anchored for the provision of new sunshade,gently and finish the surface of the around the rebar area, using thesame material which comes out of the hole excessively.

No. 650 650 650 1950

                                                                      2 of 47                                                                            

Page 3: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.c ANTICORROSIVE COATING

ANTICORROSIVE COATING :Clean the rebars using the rustremover if there exists any rust, otherwise clean the rebar free offoreign material. Mix the base and hardener of the zinc rich epoxyresin mechanically using a slow speed heavy duty drilling machinefitted with mixing paddle. Apply the mixed materials to the cleanedrebar and allow it to dry complete.

Kg 12 12 12 36

d PROVISION OF REINFORCEMENTPROVISION OF REINFORCEMENT : Providing, fabricating,placing and tying the new reinforcement for the sunshades as per thestandard specification including the cost of binding wire, cost ofRTS/MS bars, etc.. - complete.

Kg 450 450 450 1350

e APPLICATION OF EPOXY JOINTING COMPOUNDAPPLICATION OF EPOXY JOINTING COMPOUND : Mix thebase and hardener of the epoxy jointing compound using a slowspeed heavy duty drilling machine fitted with mixing paddle andapply the same to the prepared lintel beam/beam surface. Make surethat the concreting is done within 3 hours and the application shouldbe done in such a way that the allowance for concreting be kept inmind.

Sqm 10 10 10 30

                                                                      3 of 47                                                                            

Page 4: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.f PROVISION OF GALVANIC ANODES

PROVISION OF GALVANIC ANODES : Prior to installation of theGalvashield XP units, check the continuity of the steelreinforcement. Any loss of continuity will require additionalelectrical connections or restoration of continuity by effectivemeans. Select a location for the Galvashield XP as close as practicalto the edge of the dismantled location of the repair zone. GalvashieldXP units should be positioned around/along the repair boundary. Inaddition to standard substrate preparation, the Galvashield XPanode(s) shall be thoroughly pre-soaked in clean water for aminimum of 4 hours and a maximum of 6 hours, prior to theapplication of the repair mortar. Tighten tie wires using GalvashieldFixing Tool so that no free movement is possible, thus ensuring goodelectrical continuity. To test electrical continuity between tie wiresand reinforcement bar a continuity meter should be used.

No. 45 45 45 135

g FORM WORKFORM WORK : Centering and shuttering including strutting,propping , etc.. As per the required line and length at all differentfloor levels as per the standard specification-complete.

Sqm 65 65 65 195

                                                                      4 of 47                                                                            

Page 5: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.h CONCRETING

CONCRETING :-Centering and shuttering including strutting,propping , etc.. Providing, laying concrete of M20 Grade includingcost of cement, aggregate,etc..but excluding the cost of centering,shuttering and finishing and reinforcement but including the concrete admixture conforming to IS:9103 to improve workability withoutaffecting the strength and durability as directed by the engineer-in-charge.(The cement used shall be ordinary Portland cementconfirming to IS 12269 (1987) - OPC 53, Grade & BIS IS 8112(2013) - OPC 43 Grade of approved quality and brand Using beforeto produce the test certificate. If the brands are changed again has toproduce the test certificates for the new brands).

Cum 3 3 3 9

i CURINGCURING : Provide temporary band along the outer edge of the

sunshade so as stagnate water on the sunshade atleast for a minimumperiod of 10 days from the time of casting of concrete as for as thehorizontal surface is concerned. With respect to the vertical finswhich acts as part of the sunshade for the purpose of elevation, soonafter the formwork is removed, apply the water on the surface of theconcrete to keep the surface moist. Mix the acrylic based compoundwith water in the ratio of 1:1 and apply the same to the entireconcrete surface-complete.

Sqm 50 50 50 150

                                                                      5 of 47                                                                            

Page 6: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.j PLASTERING

PLASTRING: Hack the surface of the RCC member area of thesunshade and provide the mechanical bond for the plaster. Providecement sand mortar 1:3 added with waterproofing admixture,normally at the rate of not more than 150ml per bag of cement.Plaster the surface using the prepared mortar to the required line andlength, followed by curing the surface. Curing shall be started assoon as the plaster has hardened sufficiently.The plaster shall bekept wet for a period of at least 7 days. During this period, it shall besuitably protected from all damages at the contractor’s expense bysuch means as the Engineer-in-Charge may approve.

Sqm 70 70 70 210

3 POLYMER MODIFED MORTARPOLYMER MODIFED MORTAR : Chip off the corrosion damagedareas on the beam/column/sunshade or any other structural members.Clean reinforcement and make sure that there are no traces of rust onthe surface of existing rebars. Check for the depth of carbonationusing the phenophthaline indicator and make sure that thecontaminated concrete is removed completely. Wet the surface withpotable water and make sure that the surface is kept moist so that thewater cement ratio in the polymer modified mortar is maintained.Prepare the acrylic based jointing compound by mixing the acrylicwith water and cement in the ratio of 1:3:1 and apply the same to theprepared surface as primer. Prepare cement sand mortar 1:3 addedwith the polymer at the rate of 2 litres per bag of cement and applythe same to the primed surface followed by a smooth finish. Soonafter the finishing is over, apply the curing compound as stated in theitem number 2 - i

Sqm 15 15 15 45

                                                                      6 of 47                                                                            

Page 7: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.4 MICRO CONCRETINGa SURFACE PREPARATION

Chip off the corrosion damaged areas on the beam/column/sunshadeor any other structural members. Clean reinforcement and make thatthere is no traces of rust on the surface existing rebars. Checl for thedepth of carbonation using he phenopthaline indicator and ake surethat the contaminated concrete is removed completly. Make sure thatthe chipping is ddoen till the rear side of the rebar so that thecorrosion patches and also the application of the anticorrosiveocating can be done properly.

Sqm 40 40 40 120

b SHEAR CONNECTORS

SHEAR CONNECTORS : Drilling 12mm dia holes up to a depth of75mm maximum and fixing 8mm dia L shaped anchor rods as shearconnectors at every 300mm c/c on the surfaces of the columns/beamsor any other structural member as the case may be. Clean the sameusing water and make sure that there are no fine particles present inthe hole. Mix the base and hardener of the polyester resin with thespatula thoroughly. Fill the drilled and cleaned holes to a minimumdepth of 1/3rd of the hole with the prepared polyester resin. Makesure that the resin has reached till the end of the hole. At this stagepush the shear connector gently in to the hole and finish the excessresin which comes out of the hole and allow the shear connectors notto be disturbed for minimum 20 minutes - complete.

No. 375 375 375 1125

                                                                      7 of 47                                                                            

Page 8: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.c ADDITIONAL REINFORCEMENT

ADDITIONAL REINFORCEMENT : Check the diameter of theexisting rebars and if the diameter is less than 50% of the originaldiameter, provide additional reinforcement. Cut 12mm dia bars asmain reinforcement to the required length with proper developmentlength. Tie them to the prefixed shear connectors so that theadditional rebar acts monolithically with the existing ones and coreconcrete. In the case of the shear reinforcement also, if the diameterof the rebars are reduced, provide 8mm dia stirrups in the form of 2"U" shaped bars. Tie them properly so that it has a tight contact withthe main bars.

Kg 500 500 500 1500

d ANTICORROSIVE COATINGANTICORROSIVE COATING :- Clean the rebars using the rustremover if there exists any rust, otherwise clean the rebar free offoreign material. Mix the base and hardener of the zinc rich epoxyresin mechanically using a slow speed heavy duty drilling machinefitted with mixing paddle. Apply the mixed materials to the cleanedrebar and allow it to dry complete.

Kg 20 20 20 60

e APPLICATION OF EPOXY JOINTING COMPOUNDAPPLICATION OF EPOXY JOINTING COMPOUND: Mix thebase and hardener of the epoxy jointing compound using a slowspeed heavy duty drilling machine fitted with mixing paddle andapply the same to the prepared lintel beam/beam surface. Make surethat the concreting is done within 3 hours and the application shouldbe done in such a way that the allowance for concreting be kept inmind.

Sqm 35 35 35 105

                                                                      8 of 47                                                                            

Page 9: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.f PROVISION OF GALVANIC ANODES

PROVISION OF GALVANIC ANODES : Prior to installation of theXP units, check the continuity of the steel reinforcement. Any loss ofcontinuity will require additional electrical connections orrestoration of continuity by effective means. Select a location forthe Galvashield XP as close as practical to the edge of the brokenarea of the repair zone. Galvashield XP units should be positionedaround/along the repair boundary. In addition to standard substratepreparation, the Galvashield XP anode(s) shall be thoroughly pre-soaked in clean water for a minimum of 4 hours and a maximum of 6hours, prior to the application of the repair mortar. Tighten tie wiresusing Galvashield Fixing Tool so that no free movement is possible,thus ensuring good electrical continuity. To test electrical continuitybetween tie wires and reinforcement bar a continuity meter should beused.

No. 50 50 50 150

g FORM WORK

FORM WORK : Supply of slurry tight form work which should notdeform and leak due to pressure of micro concrete. Provision shouldbe made for a suitable feed hopper for pouring concrete. The formwork should be coated with the mould release agent prior to finalfixing in position. Proper supporting arrangements to be made forkeeping the shutter in correct line and length - complete.

Sqm 40 40 40 120

                                                                      9 of 47                                                                            

Page 10: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.h MICRO CONCRETING

MICRO CONCRETING :-Stock sufficient quantity of microconcrete and 12mm down graded chips on site to enable thecompletion of the pouring in a continuous operation. An approvedconcrete mixer or a slow speed heavy duty drilling machine fittedwith mixing paddle shall be used. Mix the micro concrete and the12mm down grade chips in the ratio of 1: 0.5 by weight withrequired quantity of water and place the same to the prefixedformwork well before the epoxy jointing compound dries up.Remove the formwork after 24 hours in the case of columns andafter a period of 72 hours in the case of slab and beam and check forany surface defects and if so apply te polymer modified mortar -complete.

Sqm. 40 40 40 120

i CURINGCURING :-Soon after the formwork is removed, apply the water onthe surface of the concrete to keep it moist. Mix the acrylic basedcompound with water in the ratio of 1:1 and apply the same to theentire concrete surface-complete.

Sqm 40 40 40 120

j CORE CUTTING

CORE CUTTING :-Mark the core holes along the beam to facilitatefor the pouring of micro concrete. The core cutting need to be donewith an electrically operated core drilling machine fitted withdiamond tool of dia not less than 72mm and to the entire depth of theslab portion. Care to be taken to minimize the cutting of the rebar asreinforcements are expected at the negative bending moment zone.

No. 25 25 25 75

                                                                      10 of 47                                                                            

Page 11: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.k PLASTERING

PLASTRING :-Hack the surface of the RCC member area of thebeam/columns, etc..to provide the mechanical bond for the plaster.Provide cement sand mortar 1:3 added with waterproofingadmixture, normally at the rate of not more than 150ml per bag ofcement. Plaster the surface using the prepared mortar to the requiredline and length, followed by curing the surface. Curing shall bestarted as soon as the plaster has hardened sufficiently.The plastershall be kept wet for a period of at least 7 days. During this period, itshall be suitably protected from all damages at the contractor’sexpense by such means as the Engineer-in-Charge may approve.

Sqm. 45 45 45 135

5 TOILET SUNKEN AREA :-WATERPROOFING TO THE SUNKENPORTION

a SURFACE PREPARATIONSURFACE PREPARATION :- Dismantling existing toilet includingflushing cistern,wash basin etc including all fixtures &fittings, tiles& brick jelly concrete all complete including stacking of usefulmaterials near the site and disposal of unserviceable materialsoutside the premises to a distance as per the instructions of theEngineer in charge.(It is measured in Cum only.Whatever the debrisremoved form that sunkens is calculated top the floor tiles to thesunken slab top).

Cum 20 23 23 66

                                                                      11 of 47                                                                            

Page 12: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.b WATERPROOFING

WATERPROOFING :-All the surfaces which are to receive thewaterproofing coating like Brushbond, must be free from dirt or anyother form of foreign matter which might affect adhesion. Acid washand water wash the surface and allow it to surface dry condition.Mix the part A and part B of the polymer modified cementitouscoating mechanically using an electrical operated heavy drillingmachine fitted with mix paddle. Apply the same in two coats overthe prepared surface one after the other dries up with a minimuminterval of 4 hours between the coats. Providing pressure grouting inall the vertical and horizontal joint including the suspected areas.19mm dia holes in the slab at 1.0 m c/c to a depth of about 75 mmand provide PVC nipples using rapid setting cement to serve asnozzles for grouting. Prepare cement slurry with shrinkagecompensating additive (Cebex 100 manufactured by M/s Fosroc Chemicals or equivalent)for grouting the same Inject the same using a positive displacementhand operated pressure grouting pump until the nipple refuses thegrout. Cut the nipple and finish the same. Stagnate the water for aminimum period of 3 days.

c PROTECTIVE PLASTERPROTECTIVE PLASTER :-Providing cement sand mortar 1 :4 andapply the same to an average thickness of 12 mm cement finishedwith a floating coat of neat cement mix with water proofingcompound of approved quality in proportion recommended by themanufacturer.

Sqm 160 180 180 520

Sqm 160 180 180 520

                                                                      12 of 47                                                                            

Page 13: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.d REDOING THE BRICKJELLY CONCRETE

REDOING THE BRICKJELLY CONCRETE: Toilet Sunken BrickJelly concrete with the ratio of 1:3:6 (1 part cement,3 part and 6 partbrick jelly.) in Toilet, Balcony and service area sunken withnecessary compaction, curing etc., complete with standardspecifications and as directed by Departmental Officers.waterproofing liquid (Conplast X421 IC manufactured by M/sFosroc Chemicals or equivalent) at the rate of 125 ml per bag ofcement to the required line and levels. Care to be taken to allowsufficient time for the water to evaporate from the insulating systembefore laying the Anti skid Ceramic tiles with the cement mortar asper the standards.

Cum 23 23 23 69

e RELAYING OF TILES

RELAYING OF TILES :Providing and fixing 1st quality ceramicglazed tiles conforming to IS : 13753 of minimum thickness 5mm ofapproved make in all colours ,shades except burgundy, bottle green,black of any size as approved by Engineer-In-Charge in skirting,risers of steps and dados over 12mm thick bed of cement mortar 1:3( 1 cement : 3coarse sand) and jointing with grey cement slurry 3.3kg per sqM including pointing in white cement mixed with pigmentof matching shade complete. Size upto 300x300mm

(i) Flooring size - 300x300mm Basic Rate: Rs.50.00 Sqm. 74 90 90 254(ii) Dadoing Tile size - 300x600mm Basic Rate: Rs.50.00 Sqm. 358 438 438 1234

                                                                      13 of 47                                                                            

Page 14: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.6 ROOF WATERPROOFINGa DISMATELING THE WEATHERING COURSE

DISMATELING THE WEATHERING COURSE :- Dismantlingexisting pressed clay tiles & brick jelly concrete all completeincluding disposal of the debris after bringing the same to the groundlevel to a location outside the premises as per the intructiuons of theEngineer in charge. Make sure that there is no traces of the brickjelly concrete and expose the parent concrete complete.

Cum 40 40 40 120

b WATERPROOFING

All the surfaces which are to receive the waterproofing coating likeBrushbond, must be free from dirt or any other form of foreignmatter which might affect adhesion. Acid wash and water wash thesurface and allow it to surface dry condition. Mix the part A and partB of the polymer modified cementitous coating mechanically usingan electrical operated drilling machine fitted with mix paddle. Applythe same in two coats over the prepared surface one after the otherdries up with a minimum interval of 4 hours between the coats.Providing pressure grouting in all the vertical and horizontal jointincluding the suspected areas.

Sqm 475 475 475 1425

c PROTECTIVE PLASTERPROTECTIVE PLASTER :Providing cement sand mortar 1:4 andapply the same to an average thickness of 12 mm cement finishedwith a floating coat of neat cement of mix with water proofingcompound of approved quality in proportion recommended by themanufacturer.

Sqm 475 475 475 1425

                                                                      14 of 47                                                                            

Page 15: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.d REDOING THE WEATHRING COURSE

REDOING THE BRICKJELLY CONCRETE: Weathering course-using broken brick jelly 20 mm gauge in pure slacked lime (No sandto be used) over RCC roof slab. The proportion of broken brick jellyto slaked lime being 32:12½ cft (Brick Jelly lime concrete with theratio of 1:2 (1 part lime, 2 part brick jelly.) well beaten by woodenbeaters for giving required slope and thickness required etc completecomplying with standard specifications and as directed byDepartmental Officers. waterproofing liquid (Conplast X421 ICmanufactured by M/s Fosroc Chemicals or equivalent) at the rate of125 ml per bag of cement to the required line and levels. Care to betaken to allow sufficient time for the water to evaporate from theinsulating system before laying the pressed clay tiles with the cementmortar as per the standards.

Cum 40 40 40 120

e PROVIDING AND FIXING PRESSED CLAY TILESPROVIDIN & FIXING PRESSED CLAY TILES :-Providing andfixing 1st quality pressed clay tiles conforming to standards ofminimum thickness 18 mm of approved make by the Engineer-In-Charge over 12mm thick bed of cement mortar 1:3 ( 1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3 kg per sq Mincluding pointing in white cement mixed with pigment of matchingshade of the pressed clay tiles complete. The tiles needs to be laidwith proper gradient so that the water drains off immediately withoutany stagnation - complete

Sqm. 390 390 390 1170

                                                                      15 of 47                                                                            

Page 16: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.7 PROVIDING PMM FOR THE DUCT AREA

Drain the water fully and check for cracks if any. If there are cracks,fill the same using the crack filling compound. Check the conditionof coving and if required redo the same with polymer modifiedmortar. All the surfaces which are to receive the waterproofingcoating like Brushbond, must be free from dirt or any other form offoreign matter which might affect adhesion. Acid wash and waterwash the surface and allow it to surface dry condition. Mix the partA and part B of the polymer modified cementitous coatingmechanically using an electrical operated heavy duty drillingmachine fitted with mix paddle. Apply the same in two coats overthe prepared surface one after the other dires up with a minimuminterval of 4 hours between the coats. Drill 19 mm dia holes in theslab at 1.0 m c/c to a depth of about 75 mm and provide PVCnipples using rapid setting cement to serve as nozzles for grouting.Prepare cement slurry with shrinkage compensating additive

(Cebex 100 manufactured by M/s Fosroc Chemicals or equivalent)for grouting the same Inject the same using a positive displacementhand operated pressure grouting pump until the nipple refuses thegrout. Cut the nipple and finish the same.

Sqm. 450 475 475 1400

                                                                      16 of 47                                                                            

Page 17: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.8 OHT WATERPROOFING

Drain the water fully and check for the cracks if any. If there arecracks fill the same using the crack filling compound. Check theconditiion of coving and if required re do the same with polymermodified mortar. All the surfaces which are to receive thewaterproofing coating like Brushbond, must be free from dirt or anyother form of foreign matter which might affect adhesion. Acid washand water wash the surface and alow it to surface dry condition. Mixthe part A and part B of the polymer modified cementitous coatingmechanically using an electrical operated drilling machine fittedwiith mix paddle. Apply the same two coats over the preparedsurface one after the other dires up with a minimum interval of 4hours between the coats. Providing pressure grouting in all thevertical and horizontal joint including the suspected areas.

Sqm 85 85 85 255

BALCONY REPAIR9 DISMATELINGa DISMANTLING :-Mark the outer perimeter of the balcony area

which are to be demolished. Provide required safety arrangementslike barricading the area right below with isolated tape. Break theconcrete using an electrically operated chipping machine withoutcreating much of sound and vibration to the nearby areas. Thechipping should be done to the edge of the cantilever beam also.Placing the handrails in position with required arrangements likewelding, etc..Stacking of steel bars if any and disposal ofunserviceable material woutside the premises to a distance as per theinstructions of the Engineer in Charge.

Cum 8 8 8 24

                                                                      17 of 47                                                                            

Page 18: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.REPAIR FOR HAND RAIL

b Remove the steel hand rails carefully and check for the corrosion ifany at the bottom most place. If so rectify the same, with eitherapplication of anti corrosive coating or in combination of anticorrosive coating with additional piece welding. Apply the enamelpaint to the entire metal surface which are to be buried as well asprojected as per the selection of the engineer in charge.- complete.

Rm 40 40 40 120

FORM WORK, CONCRETE & PLASTERINGc Centering and shuttering including strutting, propping, bonding

agent etc.. Providing, laying concrete of M20 Grade including costof cement, aggregate, etc..and reinforcement if any to be providedincluding the concrete admixture conforming to IS:9103 to improveworkability without affecting the strength and durability as directedby the engineer-in-charge. Provide cement sand mortar 1:3 addedwith waterproofing admixture, normally at the rate of not more than150ml per bag of cement. Plaster the surface using the preparedmortar to the required line and length, followed by curing thesurface. Curing shall be started as soon as the plaster has hardened.The plaster shall be kept wet for a period of at least 7 days.

Cum 8 8 8 24

                                                                      18 of 47                                                                            

Page 19: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.10 CHIPPING AND REPLASTERING ON WALLS

The mortar of the patch, where the existing plaster has cracked,crumbled or sounds hollow when gently tapped on the surface, shallbe removed. The patch shall be cut out to a square or rectangularshape marked on the wall as directed by the Engineer-in-Charge orhis authorized representative. The edges shall be slightly under cut toprovide a neat joint. The masonry joints which become exposed afterremoval of old plaster shall be raked out to a minimum depth of 10mm in the case of brick work and 20 mm in the case of stone work.The raking shall be carried out uniformly with a raking tool and notwith a basuli, and loose mortar dusted off. The surface shall then bethoroughly washed with water, and kept wet till plastering iscommenced. Mortar of 1 : 4 mix with the specified sand shall beused, cement finished with a floating coat of neat cement of mixwith water proofing compound of approved quality in proportionrecommended by the manufacturer. The finished plastering surfaceshould have a smooth finish and should match with the surroundssurface. The method of application shall be as per the standards forsingle coat plaster work of the specified mix and all dismantledmortar & rubbish etc. shall be disposed off within 24 hours afterdismantling promptly as directed by the Engineer-in-Charge.

Sqm 300 300 300 900

Clean the cracks if any and remove the loose mortar if any. Washthe bottom surface of the sunken portion and mark 300mm c/c. Drill13mm dia holes along the marked points and provide a non returnports Mix the base and hardener of the low viscous epoxy resin likeConbextra EP 10 or equivalent and inject the same using anelectrically operated grouting machine until refuses the grout. Cutthe port and finish the nipple same to the required level.

                                                                      19 of 47                                                                            

Page 20: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.a Drilling and fixing ports No. 250 250 250 750b Injection of low viscous epoxy resin Lit. 30 30 30 90

13 FOOT RESTER IN THE DUCT AREAa Providing and fixing orange colour safety foot rest of minimum 6

mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steelbar conforming to IS: 1786 having minimum cross section as 23 mmx 25 mm and overall minimum length 263 mm and width as 165 mmwith minimum 500 mm space between protruded legs having 2 mmtread on top surface by ribbing or chequering besides necessary andadequate anchoring projections on tail length on 138 mm as perstandard drawing and suitable to withstand the bend test andchemical resistance test as per specification complete as per design.

No. 30 30 30 90

                                                                      20 of 47                                                                            

Page 21: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.14 PAINTING WORKSa Providing and applying two or more coats of premium interior

grade plastic emulsion paint of Asian Paints make or approvedEquivalent and shade as per manufacturer's specifications to theinterior surfaces of walls, ceilings, beams, columns, canopiesstaircases, lobbies, etc. and finishing smoothly, includingscaffolding, etc. complete as directed by the Engineer. The internalsurfaces should be prepared by removing old painting and Neeru byscrapping up to the plaster surface and wash the surface, levellingthe surface with the application of acrylic wall putty and applyingone coat of cement primer (water based) /interior primer for acrylicemulsion, removing damaged portion of plaster and replastering inpatches with CM 1:4 to match the surroundings in patches orstretches and to match the adjacent surfaces, (area of patches ofcement plaster exceeding 0.10 Sqm for repairs will be consideredseparately for payment) at all levels and floors before painting thesurfaces, and disposing of the debris, curing, scaffolding includingall materials, labour charges etc. complete as directed.

Sq.m 4500 5000 5000 14500

b Synthetic Enamel Paint for Wood Surfaces: Removing byscrapping blistered paint completely and preparing the old paintedsurfaces suitably as directed and providing and applying one or morecoats of first quality synthetic enamel paint of approvedmanufacturer and shade to teak wood / commercial board surfaces indoors, windows and ventillators as per specification and finishingsmoothly including applying one coat of primer to the new or oldsurfaces as required at site, including scaffolding, all materials,labour charges etc. complete as directed.

Sq.m 585 625 625 1835

                                                                      21 of 47                                                                            

Page 22: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.c Synthetic Enamel Paint for metal Surfaces : Removing by

scrapping old paint and cleaning with rust remover to prepare the oldpainted surfaces suitably and providing & applying one or morecoats of first quality synthetic enamel paint of approved make andshade to steel work viz. Grills (doors/ windows/ ventilators/Balcony balustrade) as per specifications and finishing smoothlyincluding scaffolding, all materials, labour charges etc. complete asdirected.

Sq.m 715 768 768 2251

d Providing and applying two coats of decorative Apex weatherproofemulsion ( water based paint, 100% acrylic exterior wall finish)of Asian Paints make or approved Equivalent and shade to theexternal and internal surface of the building such as external wall,balcony, sunshades, water tank, parapets, staircase area, covered parking area, compound wall etc. after removing and cleaning oldcement paint, dirt, algae, fungus, shrubs, etc. completely, byscrapping with wire brush and washing with water and repairing thedamaged patches of plaster not exceeding by 0.10 Sqm area with CM1:4 where ever required and applying one coat of Exterior WallPrimer for Apex exterior emulsion as per manufacturer's instructionsincluding scaffolding, cost of all materials, labour charges etc.complete as directed.

Sq.m 1795 2100 2100 5995

                                                                      22 of 47                                                                            

Page 23: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.e All as per item 7 above for acrylic medicine chest [ Approx. Size :

0.60m X 0.60m ]. (2' x 2') No. 13 16 16 45

f Providing and polishing front side of the main entrance doors offlats with two coats of french spirit polish of approved tint toobtain good and smooth finish etc. complete as per specificationsand as directed at site including scrapping, scaffolding cost of allmaterials, labour charges etc. complete as directed.

Sq.m 74 90 90 254

15 TILES REMOVING AND LAYING

a

Removal of Existing Mosaic Tiles Flooring using the cuttingmachines etc., without creating much noise, dust and disturbance tothe Structure as well as the neighbouring occupants, and removingand carting away the debries to Municipal yard.

Sqm 1235 1360 1360 3955

b

Removal of Existing Mosaic Tiles Skirting using the cuttingmachines etc., without creating much noise, dust and disturbance tothe Structure as well as the neighbouring occupants, and removingand carting away the debries to Municipal yard.

Sqm. 120 150 150 420

cFilling the lower levels where ever required to bring to the requiredlevel by filling screed concrete of mix 1:2:4 using 12mm anddowngraded hard granite coarse aggregate, curing etc., complete.

Cum 20 24 24 68

d

Providing and laying 600x600 mm Vitrified tiles (thickness to bespecified by the manufacturer), with water absorption less than0.08% and conforming to IS: 15622, of approved brand &manufacturer, in all colours and shade, in flooring laid on 20mmthick cement mortar 1 cement : 4 coarse sand), including grouting ofjoints with white cement and matching pigments etc., complete. Thebasic cost of the tiles taken as Rs. 80/Sqft.

Sqm. 1235 1360 1360 3955

                                                                      23 of 47                                                                            

Page 24: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.

e

Providing and laying Vitrified tiles as that of flooring in theSkirting (thickness to be specified by the manufacturer), withwater absorption less than 0.08% and conforming to IS: 15622, ofapproved brand & manufacturer, in all colours and shade, in skirting laid on 20mm thick cement mortar 1 cement : 4 coarse sand),including grouting of joints with white cement and matchingpigments etc., complete. The basic cost of the tiles taken as Rs.80/Sqft.

Sqm. 120 150 150 420

f Fixing of 18mm thick Granite Sill slab in the Main door and in theTwo bathrooms width up to 3“ matching to Door frame width. Rm. 36 48 48 132

16 STAIRCASE WORK

Dismantling the existing floor such as marble mosaic tiles, Kadappa stone on staircase tread / risers carefully without damaging the main structure, removing / disposing all the debris in closed bags out of the campus to approved dumping yards, cleaning off the floors of all the loose mortars / dust particles to receive new flooring granite slabs. All works to be done to the satisfaction of bank's engineer. The work needs to be done from ground till the terace enterance and the rate should be uniform for all the floors.

Sqmt 200 200 200 600

                                                                      24 of 47                                                                            

Page 25: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.

b

Bringing the existing floor surface to true line & level with application of required thick cement plaster of 1 : 4 at desired places, supplying and fixing of approved variety and shade of best quality machine cut & one side mirror polished granite slabs of minimum 18 mm thick with three lines (in the entrance lobby floor, staircase tread, riser, over baluster handrail and landing with bedding cement mortar of 1:3 (1 cement : 3 sand) with necessary cement grouting and filling the tile joints with matching shade cement to make the joint smooth and look like one narrow line. All works to be done to the satisfaction of bank's engineer. The work needs to be done from ground to terace door opening and the rate should be uniform for all the floors.(The area of operation will generally cover the ground floor main entrance lobby floor, staircase tread and riser & landing portions of staircase, staircase treads handrail etc.)

Sqmt 200 200 200 600

c

Edge / Corner moulding of granite slabs with electrically operated machine to give required shape to the thickness & polishing the moulded edges to mirror finish to the satisfaction of bank's engineer as directed.

rmt 160 160 160 480

17 KITCHEN WORKS

a

Dismantling of granite / kadappah slab, RCC platform, ceramic tiles, plaster, over head wooden cabinet etc in the existing kitchen, staking of unserviseable materials at site for taking away and disposing all the debris in closed bags out of the campus to BMC approved dumping yards etc. complete as directed by the Engineer.

Per kitche

n13 16 16 45

                                                                      25 of 47                                                                            

Page 26: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.

b

P/F 40mm thick cudappa stone slab with two side and one edge (vertical edge) polished for vertical support (780mm height) for granite kitchen platform including the cost of fixing by embeding edges of cudappa slab into walls and floor concrete upto 40mm and filling the gap with cement mortar 1:5 as directed including cost of all materials, labour charges, curing etc. complete.

Sqm 70 75 75 220

c

Supplying and fixing 25mm thick unpolished cudappa stone for horizontal support for granite kitchen platform and under count type sink including inserting edges of slab to walls upto 40mm, and firmly resting on vertical cudappa slab support and fill the joints with cement mortar 1:5 etc complete as directed including cost of all materials, labour charges, curing etc. complete.

Sqm 32 35 35 102

d

Supplying and fixing 18mm thick, one side mirror polished machine cut “Jet Black” colour granite slab for kitchen platform with side facie and skirting including making facing the edge bull nose moulding with matching polishing to give high gloss finish etc complete and sealing all the joints with epoxy resin based adhesive including cleaning the area. The granite slab is to be fixed over cudappa slab with CM 1:5 with cement grout and other three edges of the granite slab shall be embedded 40mm into the wall. No deduction will be made for area of granite cut for sink. The rate quoted should include cost of all materials including nose moulding of granite, cost for cutting hole for fixing sink, labour charges, curing etc. Complete. The granite before procuring should be got approved from Bank's engineer.

Sqm 40 44 44 128

                                                                      26 of 47                                                                            

Page 27: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.

e

P/F approved quality glazed ceramic tiles of size 300mm x 600mm for wall dado above the granite platform with necessary cement grout after applying a layer of cement mortar 1:4 of 12-15mm thick mixed with water proofing compound and tile joints shall be filled with jointing compound of matching colour mixed with water proofing compound complete as directed including cost of all materials, labour charges, curing etc. Complete. The surface should be brought to proper level by plastering the areas as per requirement before tiling work and no separate payment will be made in this account. The basic price of tile – Approx. About Rs.75 per sqft inclusive of VAT at shop Approved make: RAK/ Nitco/ Marbonite/ Johnson/ Kajaria.

Sqm 45 50 50 145

18 JOINERY WORKS

a

Repairs and Replacement of Door/Window/ Ventilator WoodenFrame of bath rooms in part wherever the wooden portion isdamaged.

RM 30 40 40 110

b

Supplying and Fixing 4mm thick pinheaded Ventilator louver Glasswherever required after adjusting the grooves by repair as requiredfor proper fixing after removal of damaged glass.

Per No 190 225 225 640

c Replacement of Window Grill in part for the damaged portion as perthe same design. Old grill to be removed and re-fixed. Kg 50 50 50 150

d Supply and fixing of Single Panel Sintex Doors with frame Per No 26 32 32 90

                                                                      27 of 47                                                                            

Page 28: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.

e

Providing and replacing the damaged Ventilator with new Ventilator(With new wooden members, iron rods and glass pieces), fixing itback in position, cement touch up works, painting the wooden frameand steel bars with adequate surface preparation, primer application,enamel paint etc., of size 750mm x 600 mm

No 13 16 16 45

f

Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment at all floors in thebuilding including cost of chemical emulsion, as per thespecifications given below:-Treatment of existing masonry usingchemical emulsion (with approved chemical as prescribed by theState Agricultures / Drugs Control Deptt. with dilution percentage asper the manufacturer's specification ( say Chloropyriphos / LindaneE.C. 20% with 1% concentration) @ one litre per hole at 300mminterval including drilling holes at 45 degree and plugging them withcement mortar 1:2(1 cement: 2 coarse sand) to the full depth of thehole The contractor should give guarantee for the anti-termite workfor a minimum period of 7 years. The rate quoted should be inclusiveof the cost of all materials, T & P, labour, taxes etc complete.(Antitermite Treatement considered for every floor area only).

Sqm 1280 1450 1450 4180

g

Earthwork Excavation in all soils and subsoils and to full depth asmay be directed except in rock requiring blasting inclusive ofshoring, strutting, bailing out water wherever necessary anddepositing the excavated earth with a lead of 10 mtrs within thecompound in places shown by the departmental officers and clearingand levelling the site , etc. complete complying with standardspecification.

Cum 4 4 4 13

hSupplying and filling in foundation and basement with River Sand inlayers not more than 15 cm thick well watered rammed andconsolidated etc. complete as per standard specification - for 1 Cum

Cum 0 0 0 1

                                                                      28 of 47                                                                            

Page 29: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.

i

Laying PCC 1:4:8 using 40 mm / over 20 mm machine crushed stonejelly for foundation and basement including dewatering if foundnecessary and laid in layers of not more than 15 cm thick etc.complete complying with standard specification and as directed bythe department officers. Rate for 1 Cum

Cum 0 0 0 1

j

Constructing Brick Masonry Walls with Cement Mortar 1:4 infoundation, basement and superstructure wall using second classground moulded chamber burnt bricks of size 9"x4 3/8" x 2 3/4" etccomplete complying with standard specification and drawings and asdirected by the departmental engineers

Cum 2 2 2 6

kBrick Partition wall in Cement Mortar 1:3, 11.50 Cm thgicknessusing second class chamber burnt bricks of size 9"x4 3/8"x2 3/4"including necessary scaffolding, curing = for 10 Sqm

Sqm 27 27 27 82

l Grill work Kg 500 500 500 1500m Hole for connecting Air conditioner with the out door unit No 30 56 56 142

                                                                      29 of 47                                                                            

Page 30: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

Sl.No. Description of Work Unit Block-

ABlock-B

Block-C

Total Qty Rate Total Amount in

Rs.n Removing and refixing of geyser and aquagard No 13 16 16 45o Silicon sealent around the All window ( Each Flats) No 66 80 80 226

I TOTAL FOR CIVIL WORKS

Total amount

Place : Signature Date : Name & SealAddress :

(Rupees _______________________________________________________________________________________ Only )

                                                                      30 of 47                                                                            

Page 31: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

1 Point wiringPoint wiring for light, fan, 6A switched sockets with 3R 1.5Sqmm ( Phase, neutral and earth ) FRLS insulated multi strandsingle core copper conductor wire drawn in existing concealedPVC conduits. The work also involves supply and fixing of 6Amodular switch housed in manufacturer's GI box to be concealedto wall. The switch boxes and points shall be located at existinglocations.

1.1 One light point controlled by one switch No 244 292 292 8281.2 Same as item no 1.1, but with 2-way control No 54 64 64 1821.3 Ceiling Fan point with concealed fan hook box and electronic

speed regulator No 40 49 49 138

1.4 Same as item no 1.6, but with 2-way control No 33 40 40 1131.5 6A switched socket modular type housed in GI box to be

concelaed on wall in independent locations No 258 315 315 888

1.6 Same as item no 1.5, but socket and switch fixed in light pointcontrol switch box No 155 187 187 529

1.7 Same as item no 1.1, but for controlling exhaust fan No 43 49 49 1411.8 Call bell point with modualr bell push housed in GI box to be

concealed on wall No 13 16 16 45

1.9 Ceiling light point as described against iten no:1.1, but point to befixed on ceiling No 33 36 36 105

ELECTRICAL WORK BOQ

BLOCK - A,B&C

                                                            31 of 47                                                                            

Page 32: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

2 Circuit mains2.1 Supply and installation of 3R 2.5 Sqmm ( Phase, neutral and earth

) FRLS multi strand copper wire drawn in existing concealedPVC conduits between DBs and switch boxes in includingterminations at both ends ( From LDB to switch boxes )

Mt 1860 2260 2260 6380

3 Distribution boardFollowing items shall be fixed in the existing 6-way TPN distribution board (RCBO& MCB: Legrand, Indoasian, Panasonic, Schneider & Siemens)

3.1 63A 4P RCBO, with 100ma sensitivity No 13 16 16 453.2 10A SP MCB, 10 ka, C curve No 78 90 90 2583.3 16A SP MCB, 10 ka, C curve No 40 60 60 1603.4 20A SP MCB, 10 ka, C curve No 24 48 48 1203.5 25A SP MCB, 10 ka, C curve No 36 48 48 1323.6 Blank plates No 78 72 72 2224 Power wiring

4.1 Supply and installation of 3R 2.5 Sqmm ( Phase, neutral and earth) FRLS multi strand copper wire drawn in existing concealedPVC conduits wall and termination with copper sockets at bothends for 16A sockets

Mt 1500 1800 1800 5100

4.2 Supply and installation of 3R 4 Sqmm ( Phase, neutral and earth )FRLS multi strand copper wire drawn in existing concealed PVCconduit and termination with copper sockets at both ends for 20Asockets

Mt 2500 3600 3600 9700

4.3 Supply and installation of 16A 3-pin socket and 16A switch withLED indicator, both housed in manufacturer's GI box to beconcealed on wall and placed at different locations for controllinggysers. Socket will be placed inside toilet near gyser and switchoutside toilet near the door.

No 26 32 32 90

                                                            32 of 47                                                                            

Page 33: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

4.4 Supply and installation of 16A 3-pin socket and 16A switchedwith LED indicator socket housed in manufacturer's GI box tobe concealed on wall

No 91 120 120 331

4.5 Supply and installation of 3-pin 20A metal clad socket for splitA/C units No 33 40 40 113

4.6 Supply and installation of 20A DP MCB, 10 ka housed in powdercoated MS box to be concealed on wall for controlling split A/Cunits

No 33 40 40 113

5 Telephone and TV wiring5.1 Supply and installation of 25mm dia 1.5mm thick PVC conduit to

be embedded in wall(Measurement will be taken from Tel/TV socket to outer wall of apartment )

Mt 300 550 550 1400

5.2 Supply and laying of CATE -6 pair PVC insulated telephone cable in the above mentioned conduit ( Measurement will be taken frompoint to entry point to the apartment )

Mt 300 500 500 1300

5.3 Supply and laying of RG-11 co axial cable in the above mentioned conduit ( Measurement will be taken from point to entry point to the apartment )

Mt 400 500 500 1400

5.4 Supply and fixing of modular type RJ-11 telephone socket housed in GI box to be concealed on wall No 46 56 56 158

5.5 Supply and fixing of modular type RG-11 TV socket housed in GI box to be concealed on wall No 46 56 56 158

6 Light fittings6.1 15W LED 1600lm light fitting with tube to be fixed on wall as per

technical specifications ( Philips Master T LED/ Crompton/Bajaj No 33 40 40 113

6.2 13W LED decorative wall bracket fitting ( Philips QCZ 802/Crompton/Bajaj/Osram ) as per technical specifications No 98 120 120 338

6.3 2 ft 15W LED fitting 1200lm to be fixed above dressing mirror onthe wall ( Philips BN 150 LED 13S -6500 PSE OD GR/Crompton/ Bajaj/ Osram )

No 26 32 32 90

                                                            33 of 47                                                                            

Page 34: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

6.4 15W LED pendent light fixture to be suspended from ceiling No 46 56 56 1586.5 Decorative wall fitting, water resistant for fixing in bath rooms

fitted with 2x4W LED candle No 26 32 32 90

6.6 11W LED moduler type Light Fitting No 33 40 40 1136.7 Supply and installation of surface mounting 15W LED down

lighter as per technical specifications to be mounted on the ceiling . ( PhilipsDN170C 1xDLED-6500 PSUWH/ Crompton/Bajaj )

No 16 10 10 36

6.8 Supply and installation of 10W LED street light fixture with required GI pipe bracket to be fixed on outer wall of building on all the 4 sides ( Philips BRP 022 LED 10CW MRS1 PSUGR/ Bajaj/ Crompton )

No 6 6 6 18

6.9 Supply and installation of 10W LED weather proof bulk head fitting with wire guard to be fixed on parappet wall ( Philips WT202W LED 6S CW PSU SI PC/ Crompton/ Bajaj )

No 6 6 6 18

6.10 Musical call bell to be fixed on wall No 19 22 22 636.11 1200mm sweep 3-blade ceiling fan coloured brown without speed

regulator No 74 90 90 254

6.12 Removing the existing exhaust fan, then cleaning and paintingthe fan and frame including metal louver with spray or manuallywith primer and two coats synthetic enamel paint and fixing thefan on a teak wood frame to be newly provided of sizeapproximately 400mmx400mm with section 50mmx25mmpainted with primer and two coats synthetic enamel paint and anetlon of equivalent size of the wooden frame to be embeddedbetween fan and the wooden frame and refix the fan, frame andlouver to the wall including replacing the connection wire andplug pin from the fan if necessary and also including cost of allmaterials and labour charges etc. complete as directed by theBank’s Engineer.

No 13 16 16 45

                                                            34 of 47                                                                            

Page 35: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

7 PVC conduits with conduit accessories7.1 Supply and installation of 25mm dia 1.5mm thick PVC conduit to

be concealed on wall for pulling of any additonal points at thetime of excution of work

Mt 1025 1450 1450 3925

7.2 Supply and installation of 20mm dia 1.5mm thick PVC conduit tobe concealed on wall for pulling of any additonal points at thetime of excution of work

Mt 440 530 530 1500

8 Removal of existing switch boxes, wiring, light fittings, ceilingfans and exhaust fans No 13 16 16 45

9 Common area item ( For 16 apartments )9.1 Sub main wiring

Sub Mains9.1.1 Supply and installation of 4R 10 Sqmm ( for 3 phases and neutral

)along with 2R 4 Sqmm ( for earthing ), FRLS multi strand copperwire drawn in 2R 25mm PVC conduit 1.5mm thick to beconcealed on wall including terminations at both ends withcopper crimping type sockets (From metering panel to DB fixedoutside each apartment )

Mt 75 100 100 275

9.1.2 Supply and installation of 4R 6 Sqmm ( for 3 phases and neutral)along with 2R 4 Sqmm ( for earthing ), FRLS multi strand copperwire drawn in 2R 25mm PVC conduit 1.5mm thick to beconcealed on wall including terminations at both ends withcopper crimping type sockets (From metering panel to DB fixedoutside each apartment )

Mt 75 100 100 275

9.2 Metering Panel

9.2.1

Supply and installation of metering panel fabricated out of 16SwgCRCA and powder coated to Siemens gray shade afterundergoing 7-tank process. The panel will be have one incomersection and 7 nos of outgoing feeders

                                                            35 of 47                                                                            

Page 36: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

The incoming chamber shall be provided with 3 nos 300Aporcelain cut out fuses and 1 no 200A neutral linkThe bus bar shall be 300A TPN aluminium supported on SMC

The outgoing sections shall be provided with 7 set of 3 x100Aporcelain cut out fuses and 7 set of 1 no 60A neutral link enclosedin one chamber followed by space for providing energy meter inanother chamber and 7 set of 1 no 63A TPN FSU

The cut out fuse chamber, meter chamber shall have sealingarrangement. Meter chamber will have a transparent window toveiw the meter.A 25x3mm copper bus shall be provided at thebottom of the panel

No 2 2

9.2.2

Supply and installation of metering panel fabricated out of 16SwgCRCA and powder coated to Siemens gray shade afterundergoing 7-tank process. The panel will be have one incomersection and 9 nos of outgoing feedersThe incoming chamber shall be provided with 3 nos 300Aporcelain cut out fuses and 1 no 200A neutral linkThe bus bar shall be 300A TPN aluminium supported on SMC

The outgoing sections shall be provided with 9 set of 3 x100Aporcelain cut out fuses and 9 set of 1 no 60A neutral link enclosedin one chamber followed by space for providing energy meter inanother chamber and 9 set of 1 no 63A TPN FSU

The cut out fuse chamber, meter chamber shall have sealingarrangement. Meter chamber will have a transparent window toveiw the meter.A 25x3mm copper bus shall be provided at thebottom of the panel

No 1 1 2

                                                            36 of 47                                                                            

Page 37: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

9.2.3

Supply and installation of metering panel fabricated out of 16SwgCRCA and powder coated to Siemens gray shade afterundergoing 7-tank process. The panel will be have one incomersection and 9 nos of outgoing feedersThe incoming chamber shall be provided with 3 nos 300Aporcelain cut out fuses and 1 no 200A neutral linkThe bus bar shall be 300A TPN aluminium supported on SMC

The outgoing sections shall be provided with 9 set of 3 x100Aporcelain cut out fuses and 9 set of 1 no 60A neutral link enclosedin one chamber followed by space for providing energy meter inanother chamber and 9 set of 1 no 63A TPN FSU

The cut out fuse chamber, meter chamber shall have sealingarrangement. Meter chamber will have a transparent window toveiw the meter.A 25x3mm copper bus shall be provided at thebottom of the panel

No 1 1 2

9.3 Common area DB Supply, installation, testing and commissioning of MCBdistribution board, 4-way TPN factory built double door typedistribution board completely wired with all accessories likecopper wire,neutral bar, earth bar and interconnecting PVCcopper wires and fitted with following. The same shall beconcealed to the wall.1 no incomer with 63A 4P RCBO with 100 ma sensitivity andbreaking capacity of 10 Ka6 nos 10A SP MCB, 10 ka ( 2 nos per phase ) as outgoing feedersand 6 nos dummy covers (RCBO& MCB: Legrand, Indoasian,Panasonic, Schneider & Siemens)

No 2 2 2 6

9.4 Supply and installation of 10A DP MCB, 10 ka housed in powdercoated MS box to be fixed on wall for controlling water pumps No 2 2 2 6

                                                            37 of 47                                                                            

Page 38: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

9.5 Power cableSupply and laying of 1.1 KV grade copper conductor armoured XLPE cable in excavated trenches, clamping through wall with GI clamps etc

9.5.1 3C 2.5 Sqmm copper for water pump from MCB controls Mt 30 30 30 90

End termination of power cables with SIBG glands and copper crimping sockets

9.5.3 3C 2.5 Sqmm No 8 8 8 2410 Earthing

10.1 Supply and installation of 17.2mm dia 2 Mt long low carbon steel earth electrode bonded with 250 micron copper with GI clamp to be installed in a suitable bore and filled with 50 Lbs of carbon bond envoirnment friendly back filling compound. An RCC trough of size 300x300mm shall be provided with RCC cover for protecting the electrode. ( 2 nos per block x 2 blocks as general earthing )

No 4 4 4 12

10.2 Supply and installation of 25x3mm copper flat to interconnectearth electrodes and to panels. The same to be either burried inground or camped on wall/ ceiling with suitable GI clamps. Theend terminations shall be carried out after tinning the strip forbetter conductivity.

No 50 50 50 150

11 Supply and installation of 10-pair telephone krone block housedin engineering plastic box with transparent hinged cover to befixed on wall near metering panel

No 4 4 4 12

SUB-TOTAL

II TOTAL FOR ELECTRICAL WORKS (SUPPLY + ERECTION)

                                                            38 of 47                                                                            

Page 39: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

13 BUY BACK OF ITEM AS BELOW

13.1 Switch boxes with switches, sockets etc13.2 6A piano switch one way No 468 591 591 165013.3 6A piano switch two way No 39 48 48 13513.4 6A socket outlet No 143 176 176 49513.5 16A socket and 16A switch No 26 32 32 9013.6 Fan speed regulator resistance type No 52 72 72 19613.7 40W tube light patti fitting No 65 75 75 21513.8 Fancy wall bracket fitting with lamp No 104 128 128 36013.9 Fancy pendant fitting with lamp No 3 5 5 13

13.10 1200mm sweep ceiling fan No 52 72 72 196

13.11 Aluminium wire 1.5, 2.5 and 4 Sqmm PVC insulated No 1 1 1 3

13.12 Wooden boxes with hylam sheet front plates of different sizes No 195 240 240 675

                                                            39 of 47                                                                            

Page 40: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S No Description Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate per

Unit

Erection Rate Per

Unit

Supply Amount (INR)

Erection Amount (INR)

13.13 Open type MS meter board equipped with following

13.14 40A 4P MCB with MS housing-9 No100A porcelain cut out fuses- 3 No60A neutral link- 1 nosCopper wiring for interconnections-1 Lot No 2 2 2 612-Way TPN vertical MCB DB fitted with following 32 A TP No 2 2 2 6

13.15 16A piano switch No 2 2 2 6

SUB TOTAL

Total amount for Electrical works (Supply + Erection)(Rupees _______________________________________________________________________________________ Only )

Total amount for Buy back Items(Rupees _______________________________________________________________________________________ Only )

Place : Signature Date : Name & SealAddress :

III TOTAL FOR BUY BACK OF ITEM

                                                            40 of 47                                                                            

Page 41: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S.No Description of Work Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate Per unit

Lobour Rate Per Unit

Supply Amount (INR)

Labour Amount (INR)

1

Providing & fixing of CPVC Flowguard pipe, SDR-11 asper CTS with CPVC brass threaded fittngs for hot andcold water supply conforming to ASTM standardincluding all CPVC fittings like tees, elbows, bends,unions, coupling, reducer tees, collars, etc. The work shallinclude cutting jointing with solvent cement pressuretesting the joints / pipeline for 10 kg/sq.cm hydraulicpressure, for 8 hours etc. making holes, including chasingin solid block masonry walls with groove cutting machineto required width and depth, making bores in walls,foundations and RCC slabs, making good the walls andbores in CC or CM 1:3 as applicable clearing the debris,grouting of concealed pipes, MS hooks for fixing pipes andmaking good the walls and floors.

a 20mm Mtrs 290 360 360 1,010.0

2

Providing and fixing testing and commissioning of PVC pipe for internal soil, waste to IS:13592 of SWR quality,6kg /sq.cm, including all fittings like tees, elbows, bends,collars, coupling, etc jointing with rubber ring / solventcement followed by application of leak proof adhesive likeFRP paste laid in floors inside the toilets to the requiredslope including making necessary bores in walls /foundations / concrete slab as applicable, making good thebores with CM 1:3 or cement concrete as applicable, curing etc., complete.

a 110mm (6kg/sq.cm) Mtrs 36 42 42 120.0b 75mm (6kg/sq.cm) Mtrs 30 30 30 90.0c 50mm (15kg/sq.cm) Mtrs 42 54 54 150.0

PLUMBING WORK BOQ

BLOCK - A,B&C

                                                               41 of 47                                                                              

Page 42: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S.No Description of Work Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate Per unit

Lobour Rate Per Unit

Supply Amount (INR)

Labour Amount (INR)

3

Providing and keeping in stores, shifting to the place ofinstallation, testing commissioning of PVC multi inlet floor trap of self cleansing design moulded or fabricated withwater seal not less than 50 mm with or without vent,including setting the trap in concrete as shown in drawings.Supplying and fixing stainless steel cockroach trap withrim, filters and floor grating. Trap with 2-/1/2" outlet.

Nos. 39 48 48 135.0

4

Providing & fixing of CPVC Flowguard pipe, SDR-13.5as per CTS with CPVC brass threaded fittngs for cold water supply conforming to ASTM standard including allCPVC fittings like Bends, Tees, Elbows, Collars, junction,inspection doors, cowls, offsets, access pipes, jointing withrubber ring followed by application of leak proof adhesivelike FRP paste, fixed to wall with properly fabricated MSbracket of suitable size, GI 'U' clamps with bolts, nuts andGI washers complete, for Water supply lines laid verticallyin shafts.

a 50mm Mtrs 144 145 145 434.0b 40mm Mtrs 30 30 30 90.0c 32mm Mtrs 78 75 75 228.0d 25mm Mtrs 60 60 60 180.0e 20mm Mtrs 30 25 25 80.0

                                                               42 of 47                                                                              

Page 43: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S.No Description of Work Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate Per unit

Lobour Rate Per Unit

Supply Amount (INR)

Labour Amount (INR)

5

Providing ,fixing, testing and commissioning of PVC soil,waste, vent and rain water pipe conforming to IS 13592of SWR quality pressure rates as mentioned below,including all fittings, like Bends, Tees, Elbows, Collars,junction, inspection doors, cowls, offsets, access pipes,jointing with rubber ring followed by application of leakproof adhesive like FRP paste, fixed to wall with properlyfabricated MS bracket of suitable size, GI 'U' clamps withbolts, nuts and GI washers complete, for soil and wastepipe lines laid vertically in shafts.

a 100mm (6kg/sq.cm) Mtrs 66 66 66 198.0b 75mm (6kg/sq.cm) Mtrs 158 162 162 482.0II Sanitary iteams

The work shall include cutting making of walls and floorsetc. The rates quoted shall include cost of necessaryconsumables like brass screws, CP extension nipple ofapproved make, dia and length, wooden plugs, whitecement, sealants etc. Only drilling machines shall be usedfor making the holes in the walls for fixing, no wall jumperand hammer will be allowed.

6

Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning of glazedVitreous China European water closet with concealed 'Sor P' trap, dual flush tank push button type, hush seat coverand lidEWC - Make: ParryWare C0297Seat Cover - Make: ParryWare C8071Cistern Model - Parryware C8090 Nos. 13 16 16 45.0

7

Supply Installation and keeping in stores, shifting to theplace of installation, fixing, testing and commissioning ofIndian water closet with 'S or P' trap, flush tank type,including Civil work IWC - Make: ParryWare C0117 Nos. 13 16 16 45.0

                                                               43 of 47                                                                              

Page 44: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S.No Description of Work Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate Per unit

Lobour Rate Per Unit

Supply Amount (INR)

Labour Amount (INR)

8

Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning ofchromium plated Long body bib cock -Make:ParryWare G1904A1

Nos. 52 64 64 180.0

9 Shower cock (Bath ) -Make: ParryWare G3127A1 Nos. 26 32 32 90.0

10

Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning of stainlesssteel sink with single bowl with drain board supported by C.I./M.S. painted white brackets, C.P. cast brass bottletrap with extension piece, rubber adaptor, wall flange,union, C.P. brass chain rubber plug, including cutting andmaking good the wall/floors wherever required.

Kitchen Sink - Make - Futura. CP Fitting - Make - ParrywareBottle Trap - Model - Parryware T3201A1Waste Coupling - Model - Parryware T9911A1 Nos. 13 16 16 45.0

11

Supply Installation and keeping in stores, shifting to theplace of installation, fixing, testing and commissioning ofcounter wash basin installed with brackets. The worksshall include cutting and making good the walls & floorscomplete as required.Wash Basin - Make : Parryware. Model ; C0414Bottle Trap - Model - Parryware T3201A1Waste Coupling - Model - Parryware T9911A1 Nos. 26 32 32 90.0

                                                               44 of 47                                                                              

Page 45: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S.No Description of Work Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate Per unit

Lobour Rate Per Unit

Supply Amount (INR)

Labour Amount (INR)

12Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning ofchromium plated wash basin tap without pop up.Pillar Cock - Parryware T1402A1 Nos. 26 32 32 90.0

13

Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning of slimlinetrigger operated splash health faucet complete withflexible hose, wall mounted faucet holder, excutcheonplate, fixing bolt.Health Faucet - Make - Parryware T9940A1 Nos. 26 32 32 90.0

14Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning ofchromium plated tap for IWC

Make - Parryware. Model - G1 434A1 Nos. 13 16 16 45.0

15Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning ofchromium plated sink tap

Sink cock-Model - Parryware G1421A1 Nos. 26 32 32 90.0

16Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning ofchromium plated washing machine tap

Make - Parryware. Model - G1 434A1 Nos. 13 16 16 45.0

17Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning ofchromium plated angle valveAngle Cock - Model - Parryware T9909A1 Nos. 78 96 96 270.0

                                                               45 of 47                                                                              

Page 46: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S.No Description of Work Unit Block-A

Block-B

Block-C

Total Qty

Supply Rate Per unit

Lobour Rate Per Unit

Supply Amount (INR)

Labour Amount (INR)

18Providing and keeping in stores, shifting to the place ofinstallation, fixing, testing and commissioning ofchromium plated Concealed Stopcock Nos. 39 48 48 135.0

TOTAL ( INR)

NOTE

Total amount(Rupees _______________________________________________________________________________________ Only )

Place : Signature Date : Name & SealAddress :

Qty arrived as per schematic drawing

Quantity of sanitary fixtures like wash basins, WCs, bathtubs, showers, kitchen sinks, faucets, etc. are mentioned in this BOQ. Final selection and models to be as per interior designer.

Toilet accessories like towel rail, soap tray, toilet paper holder, etc. not included in this BOQ as the same are considered as part of interior design / selection.

TOTAL AMOUNT (SUPPLY + LABOUR) IN RS.

                                                               46 of 47                                                                              

Page 47: NABARD -BOQ - R4 - 17.10.16 · 2018. 9. 22. · CIVIL WORKS BOQ BLOCK - A,B&C 1 of 47. Sl.N o. Description of Work Unit Block-A Bloc k-B Bloc k-C Total Qty Rate Total Amount in Rs.

S. No DESCRIPTION OF WORK AMOUNT in Rs.

I Civil Works

II Electrical works

III Electrical works( BUY BACK ITEM) (-)

IV Plumbing works

VPlumbing works (BUY BACK ITEMS - Internal, External piping, shower cock, bib cock, wash basin, EWC, IWC etc.,) LS. (-)

A Total Value (I+II-III+IV-V)

TOTAL VALUE (A) IN Rs.

Total Value (A) in Words Rs. ______________________________________________________________

*NOTE:

Place :Date : Signature Address : Name & Seal

The item not covered in the Bill of quantities of this contract document shall be paid as per rate analysis based on documentary proof with 15% towards contractor's overhead profit and all applicale taxes. The rate analysis shall be submitted by the contractor for scrutiny and approval of the PMC/NABARD

________________________________________________________________________________ Only )

ABSTRACT

REHABILITATION WORK FOR NABARD STAFF QUARTERS, BAZULLAH ROAD AT T.NAGAR, CHENNAI - 600 017.

SUMMARYBLOCK - A,B&C