N5412A SAS Electrical Performance Validation and Compliance Test Software
SAS Compliance Test Presentation Page 2
Serial Attached SCSISmall Computer Serial Interconnect (SCSI) just got a whole lot smaller, faster & more versatile.
•Performance – Gen 1 at 300MBytes/sec per lane
•Scalability – Multi-port, long cables, up to 1.2GBytes/sec
•Reliability and Availability – Secondary failover, P2P
•Flexibility – Supports SAS & SATA drives and SCSI SW
SAS Compliance Test Presentation Page 3
HDD/ODD
SubsystemsComponentsStorage
Interconnect
Heterogeneous Data SolutionsHP Server/Brocade/EMC Storage
Host Bus AdaptersSemiconductors
System Integrators
Heterogeneous Data SolutionsHP Server/Brocade/EMC Storage
Motherboards
SATA Storage Market Segments
Allion ComputerFaraday
Technology Corp.Genesys Logic
AmericaJmicron
Technology Corp.LSI Logic
LyCOM TechnologyNetCell
CorporationPanasonic
SILICONSTORSUNEXT Design
STMicroelectronics
MarvellSilicon Image
ACARD Technology Corp.
Agere SystemsFujitsu Computer
ProductsHitachi GSTSamsungSeagate
STMicroelectronicsToshiba
Western DigitalLite On
TechnologiesIomega Corp.Media Tek Inc.
Philips
AdaptecAddonics
TechnologyAMCC
Jmicron TechnologyLSI LogicNetcell
TechnologyPacific Digital
Corp.3Ware
IntelDellHP
Scientific AtlantaATI Technologies
SAS Compliance Test Presentation Page 4
SAS Storage Market Segments
HDD
SubsystemsComponents Storage Interconnect
Heterogeneous Data SolutionsHP Server/Brocade/EMC Storage
HBA/RAID/Expander
Semiconductors
System Integrators
Heterogeneous Data SolutionsHP Server/Brocade/EMC Storage
Server / PC MB
SAS Compliance Test Presentation Page 5
HDD Interfaces for Multi-user Market
0
5,000
10,000
15,000
20,000
25,000
30,000
35,000
40,000
2004 2005 2006 2007 2008
Th
ou
san
ds o
f U
nit
s
PATA/ SATA
FC-AL
SAS
Parallel SCSI
(Gartner Ref. 3)
SAS Compliance Test Presentation Page 6
Market Trends
We’re primed to meet this major transition from existing parallel to serial!
Source: http://www.scsita.org
SAS Compliance Test Presentation Page 7
Market Trends
Tek
Compliance
Test
Tek’s solution is based on a 2003 version of the standard and offers no method of connectivity to the
DUT!
SAS Compliance Test Presentation Page 8
Market Trends
Tek
Compliance
Test
Agilent
Compliance
Test
Agilent’s solution is based on the 2005 version of the standard and directly leverages the UNH-IOL SAS
test suite!!!
SAS Compliance Test Presentation Page 9
N5412A is modeled after the industry standard
•UNH-IOL SAS Test Suite is the industry standard.
•Interoperability testing starts at the PHY layer.
•Our solution is complete:
• Minimum of a 10GHz real-time scope
• Reference test loads and connectivity as per the specification
• Provide common tests and algorithms to the UNH-IOL solution
SAS Compliance Test Presentation Page 10
Product DefinitionThe N5412A SAS Electrical Compliance Test application:
•Supports Gen 1(1.5Gbps) and Gen 2(3Gbps) data rates
•Supports the IT, CT Transmit (TX) interfaces and the IR, CR Far-end Transmit (TX) interfaces
•Provides automated 81134A stimulus for OOB signal tests
•REQUIRES that the PHY (DUT) be able to generate CJTPAT, the Compliance Jitter Test Pattern, for testing
•Additionally, Agilent will provide the most common x2 internal drive/host test fixture (Zero-Length Test Load), Transient Test Fixture and Transmitter Compliance Transfer Function (TCTF) for the IT compliance point testing.
SAS Compliance Test Presentation Page 11
N5412A SAS Electrical Compliance Test CoverageThe N5412A SAS Electrical Compliance Tests:•Maximum/Minimum Rising Time.
•Maximum/Minimum Falling Time.
•Eye Inner amplitude(or minimum eye opening).
•Max peak to peak output amplitude.
•Maximum Noise during OOB idle time.
•Maximum transmitter device off voltage.
•Maximum transmitter output imbalance.
•OOB offset delta.
•OOB common-mode delta.
•Maximum jitter.
•Maximum skew.
•Maximum voltage at non-operational.
•Minimum OOB burst amplitude.
•Maximum Transients.
•Bit Rate.
SAS Compliance Test Presentation Page 12
SAS Compliance Points
SAS Compliance Test Presentation Page 13
SAS Interface Connector Descriptions
Type Section
Ref. pg.
Connector ref. Interface Name
Internal 5.2.3.2.1
pg. 98
SFF-8482
SAS x2 Internal Plug Connector
Internal 5.2.3.2.2
pg. 98
SFF-8482
SAS x2 Internal Cable Receptacle
Internal 5.2.3.2.3
pg. 99
SFF-8482
SAS x2 Internal Backplane Receptacle
Int. Wide 5.2.3.4.2
pg. 108
SFF-8484
SAS x4 Internal Wide Cable Receptacle Connector
Int. Wide 5.2.3.4.3
pg. 109
SFF-8484
SAS x4 Internal Wide Plug Connector
Int. Wide 5.2.3.4.5
pg. 111
SFF-8087/86
SAS x4 Internal Compact Wide Plug Connector
Int. Wide 5.2.3.4.6
pg. 112
SFF-8087/86
SAS x4 Internal Compact Wide Receptacle Connector
External 5.2.3.3.2
pg. 101
SFF-8470
SAS x4 External Cable Plug Connector
External 5.2.3.3.3
pg. 101
SFF-8470
SAS x4 External Receptacle Connector
External 5.2.3.3.5
pg. 103
SFF-8088/86
SAS x4 External Compact Cable Plug Connector
External 5.2.3.3.6
pg. 104
SFF-8088/86
SAS x4 External Compact Receptacle Connector
SAS Compliance Test Presentation Page 14
SFF-8482 SAS x2 Internal Connectors
SFF-8482 Plug (Drive/Backpl
ane / IT Interface)
SFF-8482 Cable
Receptacle / IR
Interface
SAS Compliance Test Presentation Page 15
SFF-8484 SAS x4 Internal Connectors
SFF-8484 Cable
Receptacle / IR
Interface
SFF-8484 Plug (HBA
/ IT Interface)
SAS Compliance Test Presentation Page 16
SFF-8470 SAS x4 External Connectors (
SFF-8470 External
Receptacle / CT
Interface
SFF-8470 Plug (Inter-
Enclosure / CR Interface)
SAS Compliance Test Presentation Page 17
Simplistic Single-Port Server ConfigurationA SATA host is analogous to a SAS initiator device; a SATA
device is analogous to a SAS target device. Compliance is defined at the connectors for both buses.
Connector Topology
SATA x1 connector receptacle
SAS Host: SFF-8482 receptacle
SAS Device: SFF-8482 receptacle
SAS Compliance Test Presentation Page 18
Simplistic 4-Port Server ConfigurationA 4-port SAS controller (host bus adapter, usually PCI-X or
PCIe to SAS) will have an internal x4 connector, and will fan out to four individual x1 connectors on SATA or SAS drives. In this case, only the primary port will be used and the secondary port remains unused.
Connector Topology
SAS Host: SFF-8484 receptacle
SAS Device: SFF-8482 receptacle
SAS Compliance Test Presentation Page 19
SAS Test Fixture Requirements
In general, SAS compliance testing will require:
•An adapter from the SAS connector to SMA
•A TCTF (omitted for ZLTL tests)
•A termination network (provided by scope 50-ohm terminations OR Transient Test Circuit)
SAS Compliance Test Presentation Page 20
SAS x1 Internal (IT) Zero-Length Test Load
Available From CRUZ Systems (Worldwide Distribution)Internet: www.cruzsystems.com
Near End Test Fixture (Drive, HBA)
H303000202 iSATA Test Fixture (Drive/Host)
Far End Test Fixture (cable)
H303000102 iSATA Text Fixture (Cable)
Used for physical
layer electrical & impedance
testsUsed for
cable impedance
tests
SAS Compliance Test Presentation Page 21
SAS x2 Internal (IT) Zero-Length Test Load & TCTF
Available now! N5421A SFF-8482 Test Fixture $3000 US DDP
SAS Compliance Test Presentation Page 22
SAS x4 External (CT) Zero-Length Test Load
Available From Gore as IBNTST4X for $3800
SAS Compliance Test Presentation Page 23
SAS x4 External (CT) TCTF
Available From Molex upon request
SAS Compliance Test Presentation Page 24
Complete SAS UNH-IOL TEST COVERAGE !
Test Parameter UNH-IOL AgilentOOB Signaling TestsTX Maximum Transients Y Y
RX Maximum Transients Y Y
TX OOB Offset Delta Y Y
TX OOB Common Mode Delta Y Y
TX Minimum OOB ALIGN Burst Amplitude Y Y
TX Maximum Noise During OOB Idle Y Y
COMINIT (Device) Y Y
COMRESET (Host) Y Y
COMSAS (Host/Device) Y Y
Transmitted Signal RequirementsMaximum Skew Y Y
TX Maximum Device Off Voltage Y Y
Maximum Rise/Fall Time Y Y
Minimum Rise/Fall Time Y Y
Maximum TX Output Imbalance Y Y
Maximum J itter Y Y
TX Maximum Non- operational Voltage Y Y
Maximum Peak- Peak Voltage Y Y
Minimum Eye Opening Y YBit Rate Y Y