N WILLOW STREET - Sumner · WILLOW STREET SUMNER AVENUE C BLRB ARCHITECTS, P.S. Stamp Revised of...
Transcript of N WILLOW STREET - Sumner · WILLOW STREET SUMNER AVENUE C BLRB ARCHITECTS, P.S. Stamp Revised of...
A
B
C
D
E
F
G
HI
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
A
B
C
1
2
3
A
B
C
1
2
3
A
B
C
T
T
T
T
T
T
T
T
T
T
WILLO
W STR
EET
SU
MN
ER
A
VE
NU
E
CBLRB ARCHITECTS, P.S.
Stamp
Revised
of
Comm. No.
Sheet No.
Date
Drawing Title
Drawn
1367.114
May 31, 2017
NEW EARLY LEARNING CENTER AND
SUMNER MIDDLE SCHOOL TRACK AND
FIELD UPGRADES
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
AHBL PROJECT NO.: 2140246.10
Know what's below.before you dig.Call
R
MS/FK
DESIGN DEVELOPMENT
VICINITY MAP
NOT TO SCALE
N
EXISTING LEGEND:
SET NAIL AND
WASHER
FOUND MONUMENT
AS NOTED
HUB AND TACK
SET REBAR AND CAP
BOLLARD
MAIL BOX
SIGN
SANITARY SEWER
MANHOLE
SANITARY SEWER
CLEANOUT
STORM CATCH BASIN
STORM MANHOLE
ROOF DRAIN
GAS METER
GAS VALVE
TRAFFIC SIGNAL POLE
TRAFFIC CABINET
POWER
TRANSFORMER
GUY ANCHOR
UTILITY POWER POLE
ELECTRICAL VAULT
JUNCTION BOX
POWER METER
LUMINAIRE
TELEPHONE RISER
TELEPHONE VAULT
FIRE DEPARTMENT
CONNECTION
FIRE HYDRANT
IRRIGATION CONTROL
VALVE
HOSE BIB
WATER METER
WATER VALVE
WATER VAULT
A=APPLE, B=BIRCH,
F=FIR,
P=PINE,
HA=HAWTHORNE
HO=HOLLY, M=MAPLE,
O=OAK, U= UNKNOWN
STORM LINE
SANITARY SEWER
LINE
GAS LINE
ELECTRICAL LINE
COMMUNICATIONS
LINE
WATER LINE
IRRIGATION PER
RECORD DRAWING
OVERHEAD UTILITIES
STEAM LINE
FENCE
CONCRETE
ASPHALT
CONTOUR MAJOR
INTERVAL
CONTOUR MINOR
INTERVAL
PROPERTY/RIGHT-OF-
WAY LINE
FIRE LANE
HB
WV
N
GRAPHIC SCALE
0 60 120
1" = 60 FEET
30
TRENCH NOTE
UTILITY NOTE
TOPOGRAPHIC NOTE
FILL SPECIFICATION
IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR
MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT
REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED
AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR
WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL
TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE
WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17
RCW. CHAPTER 49.17 RCW.
THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE
APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED
BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL
DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE
COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR
ANY AND ALL DAMAGES THAT INCUR DUE TO THE CONTRACTOR'S
FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL
UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR THE
LOCATION OF UNDERGROUND UTILITIES.
THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN ON THESE
DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION
FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE
RELIABLE, AHBL CANNOT ENSURE ACCURACY AND THUS IS NOT
RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR
ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED
INTO THESE DRAWINGS AS A RESULT.
FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR
SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH
OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW,
ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD.
AN AUTOCAD DRAWING FILE IS AVAILABLE TO ASSIST WITH SITE
LAYOUT. PLEASE NOTE THAT ELECTRONIC FILES ARE PROVIDED FOR
CONTRACTOR'S CONVENIENCE AND SHALL NOT REPLACE NOR BE USED
TO SUBSTITUTE THE CONTRACT DOCUMENTS. THE CONTRACTOR IS
RESPONSIBLE FOR PROJECT LAYOUT ACCORDING TO CONTRACT
DOCUMENTS AND COST FOR ELECTRONIC AUTOCAD FILES.
PHONE: (253) 383-2422
FAX: (253) 383-2572
CONTACT: NICK RHEAUME
AUTOCAD FILE
OWNER/APPLICANT
ARCHITECT
BLRB ARCHITECTS
1250 PACIFIC AVENUE, SUITE 700
TACOMA, WA 98402
PHONE: (253) 627-5599
CONTACT:
EMAIL:
SURVEYOR
SUMNER SCHOOL DISTRICT
19701 104TH STREET EAST
BONNEY LAKE, WA 98390-7948
PHONE: (253) 891-6300
CONTACT: MR. MARK BAUMGARTEN
EMAIL: [email protected]
ARCHITECT
WEISMAN DESIGN GROUP
2329 E. MADISON STREET
SEATTLE , WA 98112
PHONE: (206) 322-1732
CONTACT: ANDY RASMUSSEN
EMAIL: [email protected]
AHBL INC.
2215 NORTH 30TH STREET, SUITE 300
TACOMA, WA 98403
PHONE: (253) 383-2422
CONTACT: DAVID FOLLANSBEE, PLS
EMAIL: [email protected]
LANDSCAPE
CIVIL ENGINEER
AHBL INC.
2215 NORTH 30TH STREET, SUITE 300
TACOMA, WA 98403
PHONE: (253) 383-2422
CONTACT: NICK RHEAUME
EMAIL: [email protected]
2160246-SH-CUP.DWG
1508 WILLOW ST.
SUMNER, WA 98390
SITE ADDRESS
NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY
CORRECTED GPS OBSERVATIONS USING WSRN AND GEOID
2012A.
VERTICAL DATUM
NAD 1983
WASHINGTON STATE PLANE SOUTH PROJECTION, BASED ON
GPS OBSERVATIONS USING WSRN AND GEOID 2012A. UNITS OF
MEASUREMENT ARE US SURVEY FEET.
BASIS OF BEARING
BOUNDARY SHOWN HEREON IS BY OTHERS. BOUNDARY WAS
ALIGNED TO FOUND CORNERS.
BOUNDARY NOTE
PROJECT
SITE
UNDERGROUND STORMWATER
INFILTRATION FACILITY
UNDERGROUND
STORMWATER
INFILTRATION
FACILITY
75.58'
EXISTING RAIN GARDEN AND
UNDERGROUND INFILTRATION
FACILITY
NEW FIRE
HYDRANT
EXISTING FIRE HYDRANT
EXISTING FIRE HYDRANT
EXISTING
FIRE HYDRANT
EXISTING
FIRE HYDRANT
EXISTING
FIRE
HYDRANT
EXISTING FIRE
HYDRANT
NEW
FIRE HYDRANT
NEW FIRE HYDRANT
P. SCHOOLS, WITH KINDERGARTEN THROUGH 8TH
GRADE LEVELS: 1.5 FOR EACH STAFF MEMBER; PLUS
DESIGNATED VISITOR SPACES AT ONE SPACE FOR
EACH SIX SEATS IN AN AUDITORIUM OR OTHER PLACES
OF ASSEMBLY;
36 STAFF X 1.5 = 54
365 ASSM / 6 = 61
TOTAL = 115 PARKING STALLS
REQUIRED STALLS
129 STALLS
124 NON ADA
5 ADA STALLS (4 STANDARD, 1 VAN)
PROVIDED STALLS
NEW EARLY LEARNING CENTER
EXISTING MIDDLE SCHOOL
59.76'
NEW
FIRE HYDRANT
FIRE LANE (TYP.)
EXISTING
FIRE HYDRANT
EXISTING FIRE HYDRANT
PARENT DROP-OFF
25' BUILDING
SETBACK
25' BUILDING
SETBACK
6' BUILDING SETBACK
10' BUILDING
SETBACK
6' BUILDING SETBACK
15' BUILDING
SETBACK
6' BUILDING
SETBACK
SYNTHETIC
TURF FIELD
& RUBBERIZED
TRACK
BASEBALL
FIELD
SOFTBALL
FIELD
FIRE LANE
BUS ACCESS
B
U
S
A
C
C
E
S
S