MZT PUMPI Documents/End... · SCP - ISO 2858 / EN 22858/ ISO 5199. SCP - ISO 2858 / EN 22858/ ISO...

84
PUMP YOUR WAY TO SUCCESS MZT PUMPI Catalog 2009 END SUCTION CENTRIFUGAL PUMPS- SCP

Transcript of MZT PUMPI Documents/End... · SCP - ISO 2858 / EN 22858/ ISO 5199. SCP - ISO 2858 / EN 22858/ ISO...

  • PUMP YOUR WAY TO SUCCESS

    MZT PUMPI

    Catalog 2009

    END SUCTION CENTRIFUGAL PUMPS- SCP

  • MZT Pumpi a.d is one of the leading manufacturers of industrial pumps in the region of South-East Europe. With its extensive experience of more than 60 years, justified with existence of broad product range, it continuously strives to satisfy the utmost needs of the customer.

    The key elements to survive in this globalized market are flexibility towards market changes and ability to innovate-both in product designs as well as business processes. By follow-ing the worldwide development in the pump industry, our staff constantly faces with the growing challenge to keep abreast of the numerous innova-tions in pump designs and this is justi-fied by having a separate R&D depart-ment.

    The basic objective of MZT Pumpi is expanding the business partnerships and building the brand name of our products worldwide. All of our employees live up to our motto:”Pump your way to success”.

  • 3

    CONTENT

    GENERAL INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

    TECHNICAL DATA - MAIN PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    TECHNICAL DATA - BEARINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

    TECHNICAL DATA - FLANGE CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    TECHNICAL DATA - SHAFT SEALING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    TECHNICAL DATA - INSTALLATION DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    SCP - ISO 2858 / EN 22858/ ISO 5199

  • SCP - ISO 2858 / EN 22858/ ISO 5199

    ApplicationFor liquid transfer and circulation of cold and hotclean or slightly polluted water, for handling aggressive organic and inorganic liquids in the chemical and petrochemical industries. Typical applications in: Municipal water supply The paper and cellulose industries Food staffs industry Domestic water supply Industrial plants Boiler feed and condensate systems Irrigation and dewatering General purposes and ets.

    BalancingAxial thrust is balanced by back vanes on DN > 400 and sealing gap on both sides if impeller diameter >500.

    Shaft SealingThe shaft sealing could be arranged by soft packing or mechanical seal.In soft packing arrangements the shaft is protected by replaceable, stainless sleeve while the stuffing box is furnished with lantern ring for introduction of cooling liquid into the packing.On special demand the pumps could be furnished with mechanical seal in accordance with the characteristics of the liquid and the operating conditions. Single mechanical seals are according EN 12756 (DIN 24960)Conversion from the gland packing to the mechanical seal is possible without any rework on the casing cover by using the relevant replacement parts.

    Back pull out designBack pull out design is attainable on special demand. The Back Pull Out design greatly facilitates maintenance of the SCP pumps.

    Forces and MomentsSCP pumps are designed for handing and moments in accordance with ISO 5199

    Testing and Guarantees Material certificates: EN 10204 Hydrostatic test: 150 % over nominal pressure

    Performance tests: in accordance with ISO 9906Warranties are given within the scope of the valid delivery conditions

    Legend:GG - Cast ironGGG - Ductile ironCS - Cast steelSS - Stainless steelDSS - Duplex stainless steelSDSS - Super duplex stainless steelBR - Bronze

    Material

    GGGGSSSSGGGG

    Optional mat.GGG,CS,SS,DSS,

    SDSS,BRGGG,CS,SS,DSS,

    SDSS,BR

    SS

    SS,DSS,SDSS

    GG,GGG, CSGGG,CS,SS,DSS,

    SDSS,BR

    Component

    Pump caseImpeller

    ShaftShaft sleeve

    Bearing bracketPump cover

    Pos.

    1.2.3.4.5.6.

    DesignHorizontal, radial split volute casing pump in back pull-out design, with radial impeller, single entry, single stage, centrifugal end-suction pump with flanged bearing frame, suitable for flexible coupling to electric motor or internal combustion engine as a driver. High operating reliability due to maintenance and service optimized parts.

    DesignationExample: SCP 50-315Pump type SCP Discharge DN [mm] 50 Nominal impeller diameter [mm] 315

    Operating RangeCapacity Q: up to 2500 m3/h 700l/sHeads H: up to 150mPump size DN 32 to 400Operating pressure p: up to 25 barOperating temperatures t: -40 to +400

    GENERAL INFORMATION

  • TECHNICAL DATA - MAIN PARTS

    Wear rings

    Front and back ( in case of impeller dia. >500mm)renewable wear rings are furnished in order to achieve the best pump performance and ease the maintenance.

    Pump case

    The pump case is of rigid design with a generous wall thickness, giving good protection against erosion and corrosion.

    Shaft sealing

    SCP pumps can be fitted with most sealing arrangements:-soft packing-mechanical seal

    Shaft bearing bracket

    The heavy duty consolewith incorporated lantern assures silent and reliable operation.

    Impeller Back vanes

    for hydraulic balancing, extending bearing life, keeps solid parts away from shaft sealing area

    Impeller

    Fully enclosed, single-piece casting gives reliability, long trouble-free operation and high efficiency.

    Shaft

    The shaft is protected by areplaceable shaft sleeve in stainless steel.

    BearingsAmple dimensioned single and double row ball bearingsimprove the stiffness and minimize shaft deflection.

    FootMachined foot assure exact positioning on baseplateand in pipework

    Pump performance

    optimized volute designhigh efficiency, smooth surfaces, minimal internal losses

    4/5

    SCP - ISO 2858 / EN 22858/ ISO 5199

    FootMachined foot assure exact positioning on baseplateand in pipework

    Pump performance

    optimized volute designhigh efficiency, smooth surfaces, minimal internal losses

  • TECHNICAL DATA - BEARINGS

    SCP - ISO 2858 / EN 22858/ ISO 5199

    Bearing bracket sizeThere are different bearing bracket size according to different size of the pump

    Nominini al imimi peller didid ameiamei terOutletnozzle [mm] 125 160 200 250 315 400 500 650

    32 BB1 BB1 BB1 BB2

    40 BB1 BB1 BB2 BB2

    50 BB1 BB1 BB2 BB2

    65 BB2 BB2 BB2 BB3

    80 BB2 BB2 BB2 BB3 BB3

    100 BB2 BB3 BB3 BB3

    125 BB3 BB3 BB3

    150 BB3 BB4 BB4 BB4 BB6

    200 BB4 BB4 BB4 BB4

    250 BB4 BB5 BB5 BB7

    300 BB6 BB6 BB7

    350 BB6 BB6 BB8

    Motor side bearingsNominini al imimi peller didid ameiamei ter

    Outlet nozzle [mm]125 160 200 250 315 400 500 650

    32 2 x 7307 2 x 7307 2 x 7307 2 x 7307 - - - -40 2 x 7307 2 x 7307 2 x 7307 2 x 7307 - - -50 2 x 7307 2 x 7307 2 x 7307 2 x 730765 2 x 7307 2 x 7307 2 x 7307 2 x 731180 2 x 7307 2 x 7307 2 x 7307 2 x 7311 2 x 7311

    100 2 x 7307 2 x 7311 2 x 7311 2 x 7311125 2 x 7311 2 x 7311 2 x 7311150 2 x 7311 2 x 7313 2 x 7313 2 x 7313 2 x 7319200 2 x 7313 2 x 7313 2 x 7313 2 x 7313250 2 x 7313 2 x 7315 2 x 7315 2 x 7324300 2 x 7319 2 x 7319 2 x 7324350 2 x 7319 2 x 7319 2 x 7324

    Impeller side bearingsNominini al imimi peller didid ameiamei ter

    Outlet nozzle [mm]125 160 200 250 315 400 500 650

    32 NU307 NU 307 NU 307 NU 307 - - - -40 - NU 307 NU 307 NU 307 NU 30750 - NU 307 NU 307 NU 307 NU 30765 - NU 307 NU 307 NU 307 NU 31180 - NU 307 NU 307 NU 307 NU307 NU307

    100 NU307 NU307 NU307 NU307125 NU307 NU307 NU307150 NU307 NU313 NU313 NU313 NU416200 NU313 NU313 NU313 NU313250 NU313 NU413 NU413 NU324300 NU416 NU416 NU324350 NU416 NU416 NU324

    The bearing assembly includes tree bearings oil lubricated, improve the stiffness and minimize shaft deflectionAll the pumps are covered by several sizes of shaft, shaft seal and bearingsDue to the ample sizes of the bearings and shafts, pumps can have several types of bearing bracketShaft is carried by, on impeller side cylindrical roller bearing and on a two ball bearing, oil lubricated. Bearing covers on both sides with ring seals.

    MZT Pumpi reserves all rights to make changes without prior notice

  • TECHNICAL DATA - FLANGE CONNECTIONS

    MZT Pumpi reserves all rights to make changes without prior notice6/7

    SCP - ISO 2858 / EN 22858/ ISO 5199

    Flange connection Suction connections flanges DIN EN 1092 PN 10 Suction connections flanges DIN EN 1092 PN 10

    Discharge connections fla Discharge connections flanges DIN EN 1092 PN 16

    Suction connections flanges DIN ENENE 1092 PN 10 Discisci hargargar e connectionectionect s flflf angeslangesl DINDINDI EN 1092 PN 16Pumpp Pumptype DN Cf df Kf Df Lf

    32-12532-16032-20032-250

    50 19 99 125 165 4xØ19

    40-16040-20040-25040-315

    65 19 118 145 185 4xØ19

    50-16050-20050-25050-315

    80 19 132 160 200 8xØ19

    65-16065-20065-25065-315

    100 19 156 180 220 8xØ19

    80-16080-20080-25080-31580-400

    125 19 184 210 250 8xØ19

    100-200100-250100-315100-400

    125 19 184 210 250 8xØ19

    125-250125-315125-400

    150 19 211 240 285 8xØ23

    150-250150-315150-400150-500150-650

    200 20 266 295 340 8xØ23

    200-250 200 20 266 295 340 8xØ23200-315200-400200-500

    250 26 320 350 395 12xØ23

    250-315250-400250-500250-650

    300 28 370 400 445 12xØ23

    300-400300-500300-650

    350 30 430 460 505 16xØ23

    350-400350-500

    350 30 430 460 505 16xØ23

    350-650 400 32 482 515 565 16xØ27

    type DN Cf df Kf Df Lf32-12532-16032-20032-250

    32 18 76 100 140 4xØ19

    40-16040-20040-25040-315

    40 19 84 110 150 4xØ19

    50-16050-20050-25050-315

    50 19 99 125 165 4xØ19

    65-16065-20065-25065-315

    65 19 118 145 185 4xØ19

    80-16080-20080-25080-31580-400

    80 19 132 160 200 8xØ19

    100-200100-250100-315100-400

    100 19 156 180 220 8xØ19

    125-250125-315125-400

    125 19 184 210 250 8xØ19

    150-250150-315150-400150-500150-650

    150 19 211 240 285 8xØ23

    200-250200-315200-400200-500

    200 20 266 295 340 12xØ23

    250-315250-400250-500250-650

    250 26 320 355 405 12xØ27

    300-400300-500300-650

    300 32 378 410 460 12xØ27

    350-400350-500

    350 36 438 470 520 16xØ27

    350-650 350 36 438 470 520 16xØ27

  • TECHNICAL DATA - SHAFT SEALING

    SCP - ISO 2858 / EN 22858/ ISO 5199

    Shaft SealingThe shaft sealing could be arranged by soft packing or mechanical seal. Conversion from the gland packing to the mechanical seal is possible without any rework on the casing cover by using the relevant replacement parts.

    Cooled stuffing box with internal barrier fluid for pumping of clean liquids in suction operation

    Single acting mechanical seal with cooling of seal surface, unbalanced Heavy Duty Rubber Bellows, Single Acting Seal with Standard Seat.

    Uncooled stuffing box without internal barrier fluid for pumping of clean liquids in suction operation

    Double –acting mechanical seal (back to back) both sides unbalanced

    In soft packing arrangements the shaft is protected by replaceable, stainless sleeve while the stuffing box is furnished with lantern ring for introduction of cooling liquid into the packing.On special demand the pumps could be furnished with mechanical seal in accordance with the characteristics of the liquid and the operating conditions. Single mech. seal are according EN 12756 (DIN 24960)

    MZT Pumpi reserves all rights to make changes without prior notice

  • TECHNICAL DATA - INSTALLATION DIMENSIONS

    MZT Pumpi reserves all rights to make changes without prior notice8/9

    SCP - ISO 2858 / EN 22858/ ISO 5199

    Dimensions (mm)SIZED1 D2 a f h1 h2 b m1 m2 n1 n2 n3 w x d l k1 k2

    32-125 50 32 80 385 112 140 50 100 70 190 140 110 285 100 24 50 M12 M1232-160 50 32 80 385 132 160 50 100 70 240 190 140 285 100 24 50 M12 M1232-200 50 32 80 385 160 180 50 100 70 240 190 140 285 100 24 50 M12 M1232-250 50 32 100 500 180 225 65 125 95 320 250 190 370 100 32 80 M12 M1240-160 65 40 80 385 132 160 50 100 70 240 190 140 285 100 24 50 M12 M1240-200 65 40 100 385 160 180 50 100 70 265 212 165 285 100 24 50 M12 M1240-250 65 40 100 500 180 225 65 125 95 320 250 190 370 100 32 80 M12 M1240-315 65 40 125 500 200 250 65 125 95 345 280 215 370 100 32 80 M12 M1250-160 80 50 100 385 160 180 50 100 70 265 212 165 285 100 24 50 M12 M1250-200 80 50 100 385 160 200 50 100 70 265 212 165 285 100 24 50 M12 M1250-250 80 50 125 500 180 225 65 125 95 320 250 190 370 100 32 80 M12 M1250-315 80 50 125 500 225 280 65 125 95 345 280 215 370 100 32 80 M12 M1265-125 80 65 100 385 132 160 50 100 70 240 190 110 285 100 24 50 M12 M1265-160 100 65 100 500 160 200 65 125 95 280 212 150 370 100 32 80 M12 M1265-200 100 65 100 500 180 225 65 125 95 320 250 190 370 140 32 80 M12 M1265-250 100 65 125 500 200 250 80 160 120 360 280 200 370 140 32 80 M16 M1265-315 100 65 125 530 225 280 80 160 120 400 315 240 370 140 42 110 M16 M1280-125 100 80 100 385 160 180 65 125 95 280 212 110 285 140 24 50 M12 M1280-160 125 80 125 500 180 225 65 125 95 320 250 190 370 140 32 80 M12 M1280-200 125 80 125 500 180 250 65 125 95 345 280 215 370 140 32 80 M16 M1280-250 125 80 125 500 225 280 80 160 120 400 315 240 370 140 32 80 M16 M1280-315 125 80 125 530 250 315 80 160 120 400 315 240 370 140 42 110 M16 M1280-400 125 80 125 530 280 355 80 160 120 435 355 275 370 140 42 110 M16 M12

    100-200 125 100 125 500 200 280 80 160 120 360 280 200 370 140 32 80 M16 M12100-250 125 100 140 530 225 280 80 160 120 400 315 240 370 140 42 110 M16 M12100-315 125 100 140 530 250 315 80 160 120 400 315 240 370 140 42 110 M16 M12100-400 125 100 140 530 280 355 100 200 150 500 400 300 370 140 42 110 M20 M12125-250 150 125 140 530 250 355 80 160 120 400 315 240 370 140 42 110 M16 M12125-315 150 125 140 530 280 355 100 200 150 500 400 300 370 140 42 110 M20 M12125-400 150 125 140 530 315 400 100 200 150 500 400 300 370 140 42 110 M20 M12150-250 200 150 160 530 280 375 100 200 150 500 400 300 370 180 42 110 M20 M12150-315 200 150 160 670 315 400 100 200 150 550 450 350 500 180 48 110 M20 M16150-400 200 150 160 670 315 450 100 200 150 550 450 350 500 180 48 110 M20 M16150-500 200 150 180 670 375 500 100 200 150 550 450 350 500 180 48 110 M20 M16200-250 200 200 180 670 355 425 100 200 150 550 450 350 500 180 48 110 M20 M16200-315 250 200 200 670 355 450 110 200 150 550 450 350 500 180 48 110 M20 M16200-400 250 200 180 670 355 500 100 200 150 550 450 350 500 180 48 110 M20 M16200-500 250 200 200 670 425 560 100 200 150 660 560 460 565 180 60 140 M20 M16250-315 300 250 250 670 400 560 130 260 190 690 560 430 500 180 48 110 M24 M16250-400 300 250 200 720 425 600 130 260 190 800 670 540 515 180 60 140 M24 M16250-500 300 250 200 720 475 670 130 260 190 800 670 540 515 180 60 140 M24 M16250-650 300 250 300 1090 500 750 225 400 300 1080 1000 630 730 250 95 170 M24 M16300-400 350 300 300 900 500 630 180 360 250 900 750 540 680 250 75 150 M24 M16300-500 350 300 300 900 560 750 225 400 300 1080 1000 630 680 250 75 150 M24 M16300-650 350 300 300 1090 600 800 225 400 300 1250 1170 800 730 250 95 170 M24 M16350-400 350 350 350 930 600 750 225 400 300 1250 1170 800 710 315 75 150 M24 M16350-500 350 350 300 900 670 850 225 400 300 1250 1170 800 630 250 75 150 M24 M16350-650 400 350 300 1150 630 850 225 400 300 1250 1170 800 740 250 110 210 M24 M16

    m1

    a

    l

    f

    h1

    m2 n3 k1n2

    w

    D2x

    d

    n1

    D1

    b

    h2

    k2

  • M Z T P U M P I

    PUMP TYPE

    SCP 25 - 160

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0140.03

    22 39 47

    55

    58

    hmax=61%

    56

    52

    19 37 45 53

    56

    59

    54

    50

    17 35 43 51

    54

    58

    52

    48

    15 33 41 50

    53

    56

    51

    47

    12 31 39 48

    52

    55

    49

    45

    9 28 37 46

    50

    53

    48

    43

    D0=170

    D1=160

    D2=150

    D3=140

    D4=130

    D5=120

    7

    12

    17

    22

    27

    32

    2

    3

    4

    5

    6

    7

    8

    9

    10

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    0,1

    0,2

    0,3

    0,4

    0

    0,1

    0,2

    0,3

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 0,2 0,4 0,6 0,8 1 1,2Q [l/s]

    0 2 4 6 8 10 12 14 16 18 20 22Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 25 - 200

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0139.03

    12 16 21

    25

    28

    max=29%

    28 27

    10 14 19

    23

    26

    27 26

    25

    8 12 17

    21

    24

    25 24

    23

    6 10 15

    19

    22

    23 22

    21

    3 7 13

    17

    20 21

    20 19

    1 5 11

    15

    18 19

    18 17

    D0=210

    D1=200

    D2=190

    D3=180

    D4=170

    D5=160 20

    25

    30

    35

    40

    45

    50

    6

    8

    10

    12

    14

    16

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    0,2

    0,4

    0,6

    0,8

    0

    0,1

    0,2

    0,3

    0,4

    0,5

    0,6

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    0

    1

    2

    3

    4

    5

    0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 0,2 0,4 0,6 0,8 1 1,2 1,4Q [l/s]

    0 2 4 6 8 10 12 14 16 18 20 22 24Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 32 - 160

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0142.03

    16 29 33

    39

    43

    hmax=46%

    45

    44

    13 26 31

    37

    41

    44

    43

    42

    11 24 29

    35 39

    42

    41

    40

    8 22 26 33

    37

    40

    39

    38

    5 19 24 31 35

    38

    37

    36

    2 17 21 28 33

    36

    35

    34

    D0=170

    D1=160

    D2=150

    D3=140

    D4=130

    D5=120

    7

    12

    17

    22

    27

    32

    2

    3

    4

    5

    6

    7

    8

    9

    10

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3 D4

    D5

    D2

    0

    0,1

    0,2

    0,3

    0,4

    0,5

    0

    0,1

    0,2

    0,3

    0,4

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    0

    1

    2

    3

    4

    0 2 4 6 8 10

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 0,5 1 1,5 2 2,5 3Q [l/s]

    0 8 16 24 32 40 48Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 32 - 200

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0143.03

    14 21 27

    37

    40

    max=41%

    40

    39

    12 19 25

    35

    38

    39

    38

    37

    10 17 23

    33

    36

    38 36

    35

    8 15 21

    32

    35

    36 35

    34

    5 13 19

    30

    33

    34 33

    32

    3 11 17

    28 32

    33 32

    30

    D0=210

    D1=200

    D2=190

    D3=180

    D4=170

    D5=160

    13

    18

    23

    28

    33

    38

    43

    48

    4

    6

    8

    10

    12

    14

    16

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    0,2

    0,4

    0,6

    0,8

    0

    0,1

    0,2

    0,3

    0,4

    0,5

    0,6

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 1 2 3 4 5 6 7 8 9 10

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 2,2 2,4 2,6Q [l/s]

    0 5 10 15 20 25 30 35 40Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 32 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0144.03

    13 18 26

    31

    35

    max=37%

    34

    28

    11 16 24

    29

    33

    35

    32

    26

    9 14 22

    27

    31

    34

    30

    24

    7 12 20

    26

    30

    32

    29

    22

    5 10 19

    24

    28

    30

    27

    21

    2 8 16

    22

    26

    29

    25

    19

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212 D5=200

    26

    31

    36

    41

    46

    51

    56

    61

    66

    71

    76

    81

    8

    10

    12

    14

    16

    18

    20

    22

    24

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    0,5

    1

    1,5

    2

    2,5

    0

    0,5

    1

    1,5

    2

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    0,5

    1

    1,5

    2

    2,5

    3

    3,5

    4

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 0,5 1 1,5 2 2,5 3 3,5Q [l/s]

    0 5 10 15 20 25 30 35 40 45 50 55 60Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 40 - 160

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0146.03

    22 39 47

    55 58

    max=61%

    56

    52

    19 37 45

    53 56

    59

    54

    50

    17 35 43

    51 54

    58

    52

    48

    15 33 41

    50 53

    56

    51

    47

    12 31 39

    48 52

    55

    49

    45

    9 28 37

    46 50

    53

    48

    43

    D0=170

    D1=160

    D2=150

    D3=140

    D4=130

    D5=120

    7

    12

    17

    22

    27

    32

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    0,2

    0,4

    0,6

    0,8

    0

    0,2

    0,4

    0,6

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    1

    2

    3

    4

    5

    6

    0

    1

    2

    0 2 4 6 8 10 12 14 16 18 20

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5Q [l/s]

    0 10 20 30 40 50 60 70 80Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 40 - 200

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0147.03

    16 29 39 46

    51

    max=55%

    53

    48

    14 27 37 44

    49

    53

    51

    46

    12 25 35 43 48

    52

    50

    45

    10 23 34 41 47

    51

    49

    43

    7 21 32 40 45

    50

    47

    42

    5 19 30 38 44

    48

    46

    40

    D0=210

    D1=200

    D2=190

    D3=180

    D4=170

    D5=160

    13

    18

    23

    28

    33

    38

    43

    48

    4

    6

    8

    10

    12

    14

    16

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4 D5

    D2

    0

    0,2

    0,4

    0,6

    0,8

    1

    1,2

    1,4

    1,6

    0

    0,1

    0,2

    0,3

    0,4

    0,5

    0,6

    0,7

    0,8

    0,9

    1

    1,1

    1,2

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 2 4 6 8 10 12 14 16 18 20 22

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5 6Q [l/s]

    0 10 20 30 40 50 60 70 80 90Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 40 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HS.0148.03

    13 25 33 40

    44

    hmax=45%

    42

    34

    11 23 31 38

    42

    43

    40

    32

    9 21 29 37

    41

    42

    39

    30

    7 19 28 35

    39

    40

    37

    29

    5 17 26 34

    38

    39

    36

    27

    2 15 24 32

    36

    37

    34

    25

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212

    D5=200

    20

    30

    40

    50

    60

    70

    80

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3 D4

    D5

    D2

    0

    0,5

    1

    1,5

    2

    2,5

    3

    3,5

    4

    0

    0,5

    1

    1,5

    2

    2,5

    3

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    4

    8

    12

    16

    20

    24

    0

    1

    2

    3

    4

    5

    6

    7

    8

    0 2 4 6 8 10 12 14 16 18 20 22

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5 6Q [l/s]

    0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 40 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0149.03

    12 17 24

    30

    34

    max=36%

    35

    34

    10 15 22

    28

    32

    34

    33

    32

    9 14 21

    27

    31

    33

    32

    31

    7 12 19

    26

    30

    32

    31

    30

    5 10 18

    24

    28

    31

    29

    28

    3 9 16

    23

    27

    29

    28

    27

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272

    D5=260 56

    61

    66

    71

    76

    81

    86

    91

    96

    101

    106

    111

    116

    121

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    1

    2

    3

    4

    5

    0

    1

    2

    3

    4

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    0

    0,5

    1

    1,5

    2

    2,5

    3

    3,5

    4

    0 2 4 6 8 10 12 14 16 18 20

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5Q [l/s]

    0 10 20 30 40 50 60 70 80Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 50 - 160

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0181.03

    21 38 51

    60

    66

    hmax=70%

    68

    59

    18 36 49

    58

    64

    68

    66

    57

    16 34 47

    57

    63

    67

    65

    55

    14 32 46

    55 62

    66

    64

    54

    11 29 44

    54 60

    65

    63

    53

    7 27 42 52

    59

    64

    61

    51

    D0=170

    D1=160

    D2=150 D3=140

    D4=130 D5=120

    0

    5

    10

    15

    20

    25

    30

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4 D5

    D2

    0

    0,2

    0,4

    0,6

    0,8

    1

    1,2

    0

    0,2

    0,4

    0,6

    0,8

    1

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    0

    1

    2

    3

    0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5 6 7 8 9 10 11 12 13Q [l/s]

    0 20 40 60 80 100 120 140 160 180 200 220Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 50 - 200

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0152.03

    28 47 60

    66

    69

    max=70%

    67

    57

    26 45 58

    64

    67

    68

    65

    55

    24 44 57

    63

    66

    67

    64

    54

    22 42 56

    62

    65

    66

    63

    53

    20 41 55

    61

    65

    66

    62

    52

    18 39 54

    60

    64

    65

    61

    50

    D0=210

    D1=200

    D2=190

    D3=180

    D4=170

    D5=160

    10

    15

    20

    25

    30

    35

    40

    45

    3

    5

    7

    9

    11

    13

    15

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    0,5

    1

    1,5

    2

    2,5

    0

    0,5

    1

    1,5

    2

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 10 20 30 40 50

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Q [l/s]

    0 20 40 60 80 100 120 140 160 180 200 220Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 50 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0153.03

    18 32 46 49

    57

    max=61%

    55

    47

    16 30 44 47

    55

    59

    53

    45

    14 28 43 46

    54

    58

    52

    44

    12 27 41 45

    53

    57

    51

    42

    10 25 40 43 52

    56

    50

    41

    8 23 38 42 51

    55

    48

    40

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212 D5=200

    20

    25

    30

    35

    40

    45

    50

    55

    60

    65

    70

    75

    80

    85

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4 D5

    D2

    0

    0,5

    1

    1,5

    2

    2,5

    3

    3,5

    4

    4,5

    5

    0

    1

    2

    3

    4

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    0

    1

    2

    3

    4

    5

    6

    0 10 20 30 40

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5 6 7 8 9 10 11 12 13Q [l/s]

    0 20 40 60 80 100 120 140 160 180 200Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 50 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0154.03

    13 25

    35

    45

    50

    max=51%

    50

    46

    11 23

    33

    43

    48

    49

    48

    44

    10 22

    32

    42

    47

    48

    47

    43

    8 20

    31 41

    46

    47

    46

    42

    6 19

    29 40

    45

    46

    45

    41

    4 17

    28 39

    44

    45

    44

    40

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272

    D5=260

    52

    57

    62

    67

    72

    77

    82

    87

    92

    97

    102

    107

    112

    117

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    0

    1

    2

    3

    4

    5

    6

    7

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    0

    0,4

    0,8

    1,2

    1,6

    2

    2,4

    2,8

    0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5 6 7 8 9 10 11Q [l/s]

    0 30 60 90 120 150 180Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 65 - 160

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0151.03

    21 42 56

    64

    70

    hmax=71%

    68

    57

    18 40 54

    62

    68

    69

    66

    55

    16 38 52

    61

    67

    68

    65

    53

    14 36 51

    59 66

    67

    64

    52

    11 34 49

    58 65

    66

    63

    50

    7 32 48 57

    64

    65

    61

    49

    D0=170

    D1=160

    D2=150

    D3=140

    D4=130

    D5=120 7

    12

    17

    22

    27

    32

    2

    3

    4

    5

    6

    7

    8

    9

    10

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    0,5

    1

    1,5

    2

    2,5

    0

    0,5

    1

    1,5

    2

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    0

    1

    2

    3

    0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19Q [l/s]

    0 30 60 90 120 150 180 210 240 270 300Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 65 - 200

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m3]. Methods and tolerances of presented performance curves

    are in accordance with ISO 9906 - Annex A

    No. 4HD.0157.03

    28 48

    59 68

    73

    max=75%

    73

    69

    26 45

    57 66

    71

    73

    71

    67

    24 44

    56 65

    70

    72

    70

    66

    22 43 55

    64

    69

    71

    69

    65

    20 42 54

    64 69

    71

    68

    65

    18 40 53

    63 68

    70

    68

    64

    D0=210

    D1=200

    D2=190

    D3=180

    D4=170

    D5=160

    19,7

    24,7

    29,7

    34,7

    39,7

    44,7

    49,7

    54,7

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    1

    2

    3

    4

    5

    0

    1

    2

    3

    4

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 10 20 30 40 50 60 70 80

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 5 10 15 20Q [l/s]

    0 50 100 150 200 250 300 350

    Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 65 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0158.03

    22 39 51 58

    62

    max=63%

    62

    52

    20 37 49 56

    60

    61

    60

    50

    18 36 48 55

    59

    60

    59

    49

    16 34 47 54

    58

    59

    58

    48

    14 32 45 53

    57

    58

    57

    46

    12 31 44 52

    56

    57

    56

    45

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212

    D5=200 26

    31

    36

    41

    46

    51

    56

    61

    66

    71

    76

    81

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    0

    1

    2

    3

    4

    5

    6

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 10 20 30 40 50 60 70

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 2 4 6 8 10 12 14 16 18 20Q [l/s]

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 65 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0159.03

    26 42

    54

    61

    63

    max=64%

    62

    61

    24 40

    52

    59

    61 62

    60

    59

    23 39

    51

    58

    60 61

    59

    58

    21 38

    50

    58 60

    61

    59

    58

    20 37 49

    57 59

    60 58

    57

    18 36 49

    56 58

    59 57

    56

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272

    D5=260

    56

    61

    66

    71

    76

    81

    86

    91

    96

    101

    106

    111

    116

    121

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    37

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    0

    1

    2

    3

    4

    5

    6

    7

    8

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    1

    2

    3

    4

    5

    6

    0

    0,2

    0,4

    0,6

    0,8

    1

    1,2

    1,4

    1,6

    1,8

    2

    0 10 20 30 40 50 60 70

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19Q [l/s]

    0 50 100 150 200 250 300Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 80 - 160

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0160.03

    26 46

    61

    69

    72

    hmax=73%

    72

    68

    23 44

    59

    67

    70

    71

    70

    66

    21 42 58

    66

    69

    70

    69

    65

    19 40 56

    65

    68

    69

    68

    64

    16 38 55

    64

    67

    68

    67

    63

    13 36 53

    62 66

    67

    66

    61

    D0=170

    D1=160

    D2=150

    D3=140

    D4=130 D5=120

    7

    12

    17

    22

    2

    3

    4

    5

    6

    7

    8

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    0,4

    0,8

    1,2

    1,6

    2

    2,4

    0

    0,4

    0,8

    1,2

    1,6

    2

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 10 20 30 40 50 60 70 80 90 100 110 120

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 5 10 15 20 25 30Q [l/s]

    0 50 100 150 200 250 300 350 400 450 500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 80 - 200

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0161.03

    26 47

    63

    72

    77

    max=78%

    72

    54

    24 45

    61

    70

    75

    76

    70

    52

    22 44 60

    69

    74

    75

    69

    51

    20 42 59 69

    74

    75

    69

    50

    18 41 58 68

    73

    74

    68

    48

    16 39 57 67

    73

    74

    67

    47

    D0=210

    D1=200

    D2=190

    D3=180

    D4=170

    D5=160

    10

    15

    20

    25

    30

    35

    40

    45

    3

    5

    7

    9

    11

    13

    15

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    1

    2

    3

    4

    5

    6

    0

    1

    2

    3

    4

    5

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 10 20 30 40 50 60 70 80 90 100 110 120 130

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 4 8 12 16 20 24 28 32 36Q [l/s]

    0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 80 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0162.03

    27 48 62

    71

    75

    max=76%

    69

    51

    25 46 60 69

    73 74

    67

    49

    23 45 59 68

    72 73

    66

    48

    21 44 58 68

    72 73

    66

    47

    20 42 57 67

    71 72

    65

    45

    17 41 56 66

    70 72

    64

    44

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212 D5=200

    16

    21

    26

    31

    36

    41

    46

    51

    56

    61

    66

    71

    76

    81

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    25

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    0

    1

    2

    3

    4

    5

    6

    7

    8

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    0

    1

    2

    3

    4

    5

    6

    0 10 20 30 40 50 60 70 80 90 100 110 120 130

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36Q [l/s]

    0 40 80 120 160 200 240 280 320 360 400 440 480 520 560Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 80 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0163.03

    23 42 53

    60

    64

    max=66%

    64

    58

    21 40

    51

    58

    62

    64

    62

    56

    20 39

    50

    57

    61

    63

    61

    55

    18 38 49

    57

    61

    63

    61

    55

    17 37 48

    56

    60

    62

    60

    54

    15 36 47

    55

    59

    61

    59

    53

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272

    D5=260

    46

    51

    56

    61

    66

    71

    76

    81

    86

    91

    96

    101

    106

    111

    116

    121

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    0,5

    1

    1,5

    2

    2,5

    3

    3,5

    4

    0 10 20 30 40 50 60 70 80 90 100 110 120

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32Q [l/s]

    0 50 100 150 200 250 300 350 400 450 500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 80 - 400

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0164.03

    22 37 48

    55

    59

    hmax=60%

    58

    52

    20 35 46

    53

    57

    58

    56

    50

    18 34 45

    52

    56

    57

    55

    49

    17 32 44

    51

    55

    56

    54

    48

    15 31 43

    50

    54

    55

    53

    47

    13 29 41

    49

    53

    54

    52

    46

    D0=405

    D1=388

    D2=371

    D3=354

    D4=337

    D5=320

    79

    89

    99

    109

    119

    129

    139

    149

    159

    169

    179

    189

    24

    26

    28

    30

    32

    34

    36

    38

    40

    42

    44

    46

    48

    50

    52

    54

    56

    58

    60

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    10

    20

    30

    0

    5

    10

    15

    20

    25

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    1

    2

    3

    4

    5

    6

    7

    0 10 20 30 40 50 60 70 80 90 100 110 120

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 4 8 12 16 20 24 28 32Q [l/s]

    0 50 100 150 200 250 300 350 400 450 500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 100 - 200

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0165.03

    25 46 61

    70

    76,5

    max=78%

    77

    70

    23 44 59

    68

    74

    76

    75

    68

    21 43 58

    67

    73

    75

    74

    67

    19 41 57

    66

    73

    75

    74

    66

    17 40 56 66

    72

    74

    73

    66

    15 38 55 65

    71

    74

    73

    65

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212

    D5=200 16

    20

    24

    28

    32

    36

    40

    44

    5

    7

    9

    11

    13

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    0

    1

    2

    3

    4

    5

    6

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    0

    1

    2

    3

    4

    0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 5 10 15 20 25 30 35 40 45Q [l/s]

    0 60 120 180 240 300 360 420 480 540 600 660 720Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 100 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0166.03

    25 48 61

    71

    75

    max=77%

    72

    57

    23 46 59

    69

    73

    75

    70

    55

    21 45 58

    68

    72

    74

    69

    54

    19 44 57

    68

    72

    74

    69

    53

    17 42 56 67

    71

    73

    68

    52

    15 41 55 66

    70

    73

    67

    51

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212 D5=200

    16

    21

    26

    31

    36

    41

    46

    51

    56

    61

    66

    71

    76

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    0

    2

    4

    6

    8

    10

    12

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    0

    1

    2

    3

    4

    5

    6

    7

    8

    0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 8 16 24 32 40 48 56Q [l/s]

    0 100 200 300 400 500 600 700 800 900Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 100 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0167.03

    22 45 58

    66

    71

    max=72%

    71

    69

    20 43 56

    64

    69

    70

    69 67

    18 42 55

    63

    68

    70

    68 66

    16 40 54

    62

    68

    69

    67 65

    14 39 53

    61 67

    67

    67 65

    12 37 52

    60 66

    67

    66 64

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272

    D5=260

    46

    56

    66

    76

    86

    96

    106

    116

    126

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    40

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    5

    10

    15

    20

    25

    0

    5

    10

    15

    20

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    0

    1

    2

    3

    0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 10 20 30 40Q [l/s]

    0 100 200 300 400 500 600 700Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 100 - 400

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0168.03

    28 56 65 67

    70

    hmax=73%

    71

    70

    26 54 63 65

    67

    70

    69

    68

    25 53 63 64

    66

    70

    68

    67

    23 52 61 64

    66

    69

    68

    67

    21 51 61 63

    65

    68

    67

    66

    20 50 60 62

    64

    67

    66

    65

    D0=405

    D1=388

    D2=371

    D3=354

    D4=337

    D5=320

    66

    76

    86

    96

    106

    116

    126

    136

    146

    156

    166

    176

    186

    196

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    40

    42

    44

    46

    48

    50

    52

    54

    56

    58

    60

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    10

    20

    30

    40

    0

    5

    10

    15

    20

    25

    30

    35

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    0

    1

    2

    3

    4

    0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 5 10 15 20 25 30 35 40 45 50Q [l/s]

    0 100 200 300 400 500 600 700 800Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 125 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0169.03

    29 51 65

    75

    80

    max=83%

    77

    67

    27 49 63

    73

    78

    81

    75

    65

    25 48 62 72

    78

    81

    74

    64

    24 47 61 72

    77

    80

    74

    63

    22 45 60 71

    77

    80

    73

    63

    20 44 59 70

    76

    79

    73

    62

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212

    D5=200

    30

    35

    40

    45

    50

    55

    60

    65

    70

    75

    5

    7

    9

    11

    13

    15

    17

    19

    21

    23

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    0

    2

    4

    6

    8

    10

    12

    14

    16

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    0 30 60 90 120 150 180 210 240 270 300

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 10 20 30 40 50 60 70 80Q [l/s]

    0 200 400 600 800 1000 1200Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 125 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0170.03

    56

    73

    80 81

    max=82%

    79%

    77

    70

    55

    72

    78 79

    80

    77

    75

    68

    54

    71

    78 79

    80

    76

    74

    67

    53 71

    77 78

    79

    76

    74

    67

    52 70

    76 78

    79

    75

    73

    66

    51 69

    75 77

    78

    74

    72

    65

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272 D5=260

    26

    36

    46

    56

    66

    76

    86

    96

    106

    116

    126

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    40

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    5

    10

    15

    20

    25

    30

    35

    40

    0

    10

    20

    30

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    5

    10

    15

    20

    25

    30

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    0 100 200 300

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 10 20 30 40 50 60 70 80 90 100Q [l/s]

    0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 125 - 400

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0171.03

    28 56 65

    67

    70

    max=73% 71

    70

    26 54 63

    65

    67

    70 69

    68

    25 53 63

    64

    66

    70 68

    67

    23 52 61

    64

    66 69

    68

    67

    21 51 61

    63

    65 68

    67 66

    20 50 60

    62 64

    67 66

    65

    D0=405

    D1=388

    D2=371

    D3=354

    D4=337

    D5=320

    79

    89

    99

    109

    119

    129

    139

    149

    159

    169

    179

    189

    24

    26

    28

    30

    32

    34

    36

    38

    40

    42

    44

    46

    48

    50

    52

    54

    56

    58

    60

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    10

    20

    30

    40

    50

    60

    0

    10

    20

    30

    40

    50

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    0

    1

    2

    3

    4

    5

    0 20 40 60 80 100 120 140 160 180 200 220 240 260

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75Q [l/s]

    0 100 200 300 400 500 600 700 800 900 1000 1100Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 150 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0172.03

    27 46

    62

    72

    77

    max=79%

    78

    72

    25 44

    60

    70

    75

    77

    76

    70

    23 43 59

    69

    74

    77

    75

    69

    21 41 58

    69

    74

    76

    75

    69

    20 40 57

    68

    74

    75

    74

    68

    17 38 56

    67

    74

    75

    74

    67

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212

    D5=200

    16

    21

    26

    31

    36

    41

    46

    51

    56

    61

    66

    71

    76

    81

    86

    91

    96

    6

    8

    10

    12

    14

    16

    18

    20

    22

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    4

    8

    12

    16

    20

    24

    28

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    0

    1

    2

    3

    4

    5

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 20 40 60 80 100 120Q [l/s]

    0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 150 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0173.03

    40 53

    65

    74

    78

    max=80%

    77

    70

    38 51

    63

    72

    76

    78

    75

    68

    37 50

    62 71

    75

    78

    74

    67

    35 49

    61 71

    75

    77

    74

    67

    33 47

    60 70

    74

    76

    73

    66

    32 46 59

    69 73

    75

    72

    65

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272

    D5=260 46

    56

    66

    76

    86

    96

    106

    116

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    36

    38

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    10

    20

    30

    40

    50

    60

    0

    10

    20

    30

    40

    50

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    5

    10

    15

    0

    1

    2

    3

    4

    5

    6

    0 100 200 300 400 500

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 10 20 30 40 50 60 70 80 90 100 110 120 130Q [l/s]

    0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200Q [US GPM]

  • M Z T P U M P I PUMP TYPE

    SCP 150 - 4001450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m3]. Methods and tolerances of presented performance curves are in accordance with ISO 9906 - Annex A

    No. 4HD.0147.03

    24 51 6069

    73,5

    max=75,9%

    71,5

    55

    22 4958

    6772

    74

    70

    53

    21 4857

    6671

    73

    69

    52

    19 47 5666

    70

    73

    68

    51

    17 46 5565

    7072

    68

    50

    15 45 5464

    6972

    67

    49

    D0=405

    D1=388

    D2=371

    D3=354

    D4=337

    D5=320

    79

    89

    99

    109

    119

    129

    139

    149

    159

    169

    179

    189

    20

    24

    28

    32

    36

    40

    44

    48

    52

    56

    60

    TDH

    [ ft

    ]

    TDH

    [ m

    ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    20

    40

    60

    80

    100

    120

    140

    0

    20

    40

    60

    80

    100

    P [ H

    P ]

    P [

    kW ]

    D0D1D3D4D5 D2

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    0

    2

    4

    6

    8

    10

    12

    14

    0 50 100 150 200 250 300 350 400 450 500 550

    NPS

    H [

    ft ]

    NPS

    H [

    m ]

    Q [m3/h]

    0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160Q [l/s]

    0 300 600 900 1200 1500 1800 2100 2400Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 150 - 500

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0175.03

    27 47 60

    66

    71

    hmax=74%

    73

    69

    26 45 58

    64

    69

    72

    71

    67

    25 45 58

    64

    69

    72

    71

    67

    24 44 57

    63

    69

    72

    71

    67

    23 43 57

    63

    68

    71

    70

    66

    22 43 56

    63

    68

    71

    70

    66

    D0=505

    D1=492

    D2=479

    D3=466

    D4=453

    D5=440 164

    174

    184

    194

    204

    214

    224

    234

    244

    254

    264

    274

    284

    294

    304

    50

    54

    58

    62

    66

    70

    74

    78

    82

    86

    90

    94

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    20

    40

    60

    80

    100

    120

    140

    160

    20

    40

    60

    80

    100

    120

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    0

    1

    2

    3

    4

    5

    6

    7

    8

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 10 20 30 40 50 60 70 80 90 100 110 120 130Q [l/s]

    0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 200 - 250

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0145.03

    27

    47

    62

    73

    81

    max=84%

    82

    73

    25

    45

    60

    71

    79

    82

    80

    71

    23

    44

    59

    70

    79

    82

    80

    70

    21

    42

    58

    70

    78

    81

    70

    70

    20 41

    57

    69

    78

    81

    79

    69

    17 40

    56

    68

    77

    80

    78

    68

    D0=260

    D1=248

    D2=236

    D3=224

    D4=212

    D5=200

    16

    21

    26

    31

    36

    41

    46

    51

    56

    61

    66

    71

    5

    7

    9

    11

    13

    15

    17

    19

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    4

    8

    12

    16

    20

    24

    28

    32

    36

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    1

    2

    3

    4

    5

    6

    7

    0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 20 40 60 80 100 120 140 160 180 200Q [l/s]

    0 400 800 1200 1600 2000 2400 2800Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 200 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0176.03

    30 50 68

    76

    83

    max=84%

    82

    80

    28 48 66

    74

    81

    82

    80

    78

    27 47 65

    73

    80

    81

    79

    77

    26 46 64

    72

    79 80

    78

    76

    24 45 63

    72

    79 80

    78

    75

    23 44 64

    71

    78 79

    77

    74

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272

    D5=260

    49

    54

    59

    64

    69

    74

    79

    84

    89

    94

    99

    104

    109

    114

    15

    17

    19

    21

    23

    25

    27

    29

    31

    33

    35

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    0

    10

    20

    30

    40

    50

    60

    70

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    0

    1

    2

    3

    4

    5

    0 100 200 300 400 500 600 700 800

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 20 40 60 80 100 120 140 160 180 200 220Q [l/s]

    0 500 1000 1500 2000 2500 3000 3500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 200 - 400

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0177.03

    27 48 64 73

    79

    hmax=80%

    79

    73

    25 46 62

    71

    77

    78

    77

    71

    24 45 61

    70

    77

    78

    77

    70

    22 44 61 70

    76

    77

    76

    70

    20 43 60 69

    76

    77

    76

    69

    18 41 59 69

    75

    76

    75

    69

    D0=405

    D1=388

    D2=371

    D3=354

    D4=337

    D5=320

    79

    89

    99

    109

    119

    129

    139

    149

    159

    169

    179

    189

    24

    26

    28

    30

    32

    34

    36

    38

    40

    42

    44

    46

    48

    50

    52

    54

    56

    58

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    20

    40

    60

    80

    100

    120

    140

    160

    0

    20

    40

    60

    80

    100

    120

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    0

    1

    2

    3

    4

    5

    6

    7

    8

    0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 20 40 60 80 100 120 140 160 180 200 220Q [l/s]

    0 500 1000 1500 2000 2500 3000 3500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 200 - 500

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0178.03

    32 54 67

    76

    80

    hmax=81%

    80

    76

    31 52 65

    74

    78

    79

    78

    74

    30 52 65

    74

    78

    79

    78

    74

    29 51 64

    74

    78 79

    78

    74

    28 51 64

    73

    77 78

    77

    73

    27 50 64 73

    77 78

    77

    73

    D0=505

    D1=485

    D2=465

    D3=445

    D4=425

    D5=405

    131

    151

    171

    191

    211

    231

    251

    271

    291

    40

    45

    50

    55

    60

    65

    70

    75

    80

    85

    90

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    40

    80

    120

    160

    200

    240

    0

    40

    80

    120

    160

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    0

    1

    2

    3

    4

    5

    6

    7

    8

    0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570 600 630 660 690 720 750

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 20 40 60 80 100 120 140 160 180 200Q [l/s]

    0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 250 - 315

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0182.03

    25 45

    63

    74

    79,5

    hmax=82%

    78

    74

    23 43

    61

    72

    77

    80

    76

    72

    21 42

    60

    71

    77

    80

    75

    71

    19 40

    59

    71

    76

    79

    75

    71

    17 39

    58 70

    76

    79

    74

    70

    15 37

    57 69

    75

    78

    74

    69

    D0=320

    D1=308

    D2=296

    D3=284

    D4=272

    D5=260 26

    36

    46

    56

    66

    76

    86

    96

    106

    8

    10

    12

    14

    16

    18

    20

    22

    24

    26

    28

    30

    32

    34

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    0

    10

    20

    30

    40

    50

    60

    70

    80

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    1

    2

    3

    4

    5

    6

    7

    0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 40 80 120 160 200 240 280 320 360Q [l/s]

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 250 - 400

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0179.03

    59 69

    75

    80

    83

    hmax=84%

    83

    81

    57 67

    73

    78

    81

    82

    81

    79

    56 66

    73

    78

    81

    82

    81

    79

    55 66

    72

    77

    80

    81

    80

    78

    54 65

    71 77

    80

    81

    80

    78

    53 64

    71 76

    79

    81

    79

    77

    D0=405

    D1=388

    D2=371

    D3=354

    D4=337

    D5=320

    66

    76

    86

    96

    106

    116

    126

    136

    146

    156

    166

    176

    186

    196

    20

    24

    28

    32

    36

    40

    44

    48

    52

    56

    60

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200

    0

    20

    40

    60

    80

    100

    120

    140

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    4

    7

    10

    13

    16

    19

    0

    1

    2

    3

    4

    5

    6

    0 100 200 300 400 500 600 700 800 900 1000 1100 1200

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 50 100 150 200 250 300Q [l/s]

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 250 - 500

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0180.03

    36 56 70

    77

    82,5

    hmax=83,6%

    82,5

    79,5

    35 54 68

    75

    81

    82

    81

    78

    34 54 68

    75

    80

    82

    80

    77

    33 53 68

    75

    80

    81

    80

    76

    32 53 67

    74

    79

    80

    79

    76

    31 52 67

    74

    79

    80

    79

    75

    D0=505

    D1=485

    D2=465

    D3=445

    D4=425

    D5=405

    131

    141

    151

    161

    171

    181

    191

    201

    211

    221

    231

    241

    251

    261

    271

    281

    291

    301

    311

    321

    30

    40

    50

    60

    70

    80

    90

    100

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    40

    80

    120

    160

    200

    240

    280

    320

    360

    400

    0

    40

    80

    120

    160

    200

    240

    280

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    0

    1

    2

    3

    4

    5

    6

    7

    0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 40 80 120 160 200 240 280 320 360Q [l/s]

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 250 - 650

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0183.03

    35 54 66

    73

    76

    max=77%

    73

    69

    33 52 64

    71

    74

    75

    71

    67

    32 52 64

    71

    74

    75

    71

    67

    31 51 63

    70

    73

    74

    70

    66

    30 50 63

    70

    73

    74

    70

    66

    29 49 62

    69

    73

    74

    69

    65

    D0=650

    D1=630

    D2=610 D3=590

    D4=570 D5=550 150

    170

    190

    210

    230

    250

    270

    290

    310

    330

    350

    370

    390

    410

    430

    450

    470

    490

    50

    55

    60

    65

    70

    75

    80

    85

    90

    95

    100

    105

    110

    115

    120

    125

    130

    135

    140

    145

    150

    155

    160

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    50

    100

    150

    200

    250

    300

    350

    400

    450

    500

    550

    600

    650

    700

    750

    0

    50

    100

    150

    200

    250

    300

    350

    400

    450

    500

    550

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D3 D4 D5 D2

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    0

    4

    8

    12

    16

    20

    24

    28

    0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800

    NP

    SH

    [ f

    t ]

    NP

    SH

    [

    m ]

    Q [m3/h]

    0 40 80 120 160 200 240 280 320 360 400 440 480Q [l/s]

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500Q [US GPM]

  • M Z T P U M P I

    PUMP TYPE

    SCP 250 - 710

    1450 [rpm]

    PUMP PERFORMANCE CURVES

    Performance curves are valid for clean cold water-kinematic viscosity 1 [mm2/s], density 1000 [kg/m

    3]. Methods and tolerances of presented performance curves are

    in accordance with ISO 9906 - Annex A

    No. 4HD.0184.03

    29 50 62 70

    74

    hmax=75%

    74

    72

    27 48 60

    68

    72

    73

    72

    70

    25 46 59

    67

    71

    72

    71

    69

    22 45 58

    66

    70

    71

    70

    68

    20 43 56 65

    69

    71

    69

    67

    17 41 55 64

    69

    70

    69 66

    D0=720

    D1=680

    D2=640

    D3=600

    D4=560

    D5=520 230

    260

    290

    320

    350

    380

    410

    440

    470

    500

    530

    560

    590

    620

    70

    78

    86

    94

    102

    110

    118

    126

    134

    142

    150

    158

    166

    174

    182

    190

    TD

    H

    [ ft

    ]

    TD

    H [

    m ]

    D0

    D1

    D3

    D4

    D5

    D2

    0

    100

    200

    300

    400

    500

    600

    700

    800

    900

    0

    60

    120

    180

    240

    300

    360

    420

    480

    540

    600

    660

    P [

    HP

    ]

    P

    [ k

    W ]

    D0 D1 D