MWS COMMERCIAL FIXTURE INTERFACE...fixtureand between lighting fixtu r e s . The line side connector...

1
MWS COMMERCIAL FIXTURE INTERFACE 120V/ 277V/ 347V 120V/ 277V/ 347V – 2 CIRC U I T, 2 NEUTRAL MWS FIXTURE CABLES The MWS Fixture Cable (FC) continues power from the Starter or Switch Drop to the first lighting fixture and between lighting fixtures. The line side connector snaps into any 1/2" knockout and has 6" #18 leads to connect to fixture wiring. MWS Fixture Cables may have length added with an Extender Cable. Positive fixture locking clip locks into any 1/2" knockout and is self grounding to the fixture or access plate. Tap leads to the fixture come standard with poke home connectors for fast termination to fixture leads. Specifications and Dimensions subject to change without notice. ORDERING INFORMATION SAMPLE NUMBER: 2 7 F C 1 2 / 2 G 0 9 Fixture cables available in #12 AWG only, rated at 20 amperes. Cooper Lighting will factory attach 9', 11', 13' and 15' fixture cables. Component FC=Fixture Cable FC Voltage 1 2 =120V 27 =277V 34 =347V Conductors and Size 1 2 / 2 G= # 12, 2 Conductor Plus Ground 1 2 / 3 G= # 12, 3 Conductor Plus Ground 1 2 / 4 G= # 12, 4 Conductor Plus Ground Options 2 N=2 Circuit, 2 Neutral ( 12/4G only). G W=Ground Wire to Fixture Cable Length 07=7 ft . 09=9 ft . 11= 11 ft . 13= 13 ft. 15= 15 ft. 17= 17 ft. 7' 2.5 lbs. 10 9' 3.0 lbs. 9 11' 3.5 lbs. 7 13' 4.0 lbs. 6 15' 4.5 lbs. 6 17' 5.0 lbs. 5 SHIPPING INFORMAT I O N Cable Unit Standard Length Wt. Qty./Carton FIXTURE CABLE FC Note: Ground wire to fixture included with GW option.

Transcript of MWS COMMERCIAL FIXTURE INTERFACE...fixtureand between lighting fixtu r e s . The line side connector...

Page 1: MWS COMMERCIAL FIXTURE INTERFACE...fixtureand between lighting fixtu r e s . The line side connector snaps into any 1/2" knockout and has 6" #18 leads to connect to fixture wiring.

MWS COMMERCIAL FIXTURE INTERFACE

1 2 0 V / 2 7 7 V / 3 4 7 V

1 2 0 V / 2 7 7 V / 3 4 7 V – 2 C I R C U I T, 2 N E U T R A L

M W S F I X T U R E C A B L E S

The MWS Fixture Cable (FC) continues p ower from the Starter orSwitch Drop to the first lighting fixture and between lighting fixtu r e s .

The line side connector snaps intoany 1/2" knockout and has 6" #18leads to connect to fixture wiring.

MWS Fixture Cables may havelength added with an Extender Cable.

• Positive fixture locking clip locks into any 1/2" knockout and is self grounding to the fixture or access plate.

• Tap leads to the fixture come standard with poke home connectors for fast termination to fixture leads.

Specifications and Dimensions subject to change without notice.

O R D E R I N G I N F O R M AT I O N

SA M PL E NUM B ER: 2 7 F C 1 2 / 2 G 0 9

Fixture cables available in #12 AWG only,rated at 20 amperes. Cooper Lighting will factory att a ch 9', 11', 13' and 15' fixture cables.

ComponentF C=Fixture Cable

FC

Voltage1 2= 12 0 V2 7= 2 7 7 V3 4= 3 4 7 V

Conductors and Size1 2 / 2 G= # 12, 2 Conductor Plus Ground1 2 / 3 G= # 12, 3 Conductor Plus Ground 1 2 / 4 G= # 12, 4 Conductor Plus Ground

Options2 N=2 Circuit, 2 Neutral( 12/4G only).G W=Ground Wire toF i x t u r e

Cable Length0 7=7 ft .0 9=9 ft .11= 11 ft .1 3= 13 ft .1 5= 15 ft .17= 17 ft .

7' 2.5 lbs. 109' 3.0 lbs. 911' 3.5 lbs. 713' 4.0 lbs. 615' 4.5 lbs. 617' 5.0 lbs. 5

S H I P P I N G I N F O R M AT I O NCable Unit StandardLength Wt. Qty./Carton

FIXTURE CABLE FC

Note: Ground wire to fixture included with GW option.