Mustertunnel CIE 88 2004 Siteco Light Consulting EN Beleuchtungstechnik GmbH - AN OSRAM BUSINESS...

43
Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESS Page 1/43 Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN Tunnel Installation : Adaptation TS30S; Interior Zone TL 21 Project number : Sample projection Customer : Processed by : Siteco Light Consulting Date : 08/2014 Project description: Sample Tunnel (CIE 88:2004) Assumed Value for Luminance in Interior Zone (day) = 4,2 cd/m² ( traffic = low) Assumed Value for Luminance in Interior Zone (night) = 1 cd/m² (tunnel = part of an unlit road) Assumed Value for Luminance in Threshold Zone = 150 cd/m² (L20=2500, k=0,06) Adaptation: 55 x 5NA854D1TA1NW (400W) 6 x 5NA854D1SA1NW (250W) 22 x 5NA854D1PA1NW (150W) Interior Zone: 48 x 5XA8638HCS5D1 (12500 lm) The determination of the lighting results is performed on a sales support basis, with great thoroughness, using the documents at our disposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). A guarantee / warranty / liability for this free calculation is not provided by SITECO. In this respect, we refer to the services of the light planning and engineering office. The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur. Guarantee claims for luminaire data are excluded. Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties.

Transcript of Mustertunnel CIE 88 2004 Siteco Light Consulting EN Beleuchtungstechnik GmbH - AN OSRAM BUSINESS...

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 1/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Tunnel

Installation : Adaptation TS30S; Interior Zone TL 21

Project number : Sample projection

Customer :

Processed by : Siteco Light Consulting

Date : 08/2014

Project description:

Sample Tunnel (CIE 88:2004)

Assumed Value for Luminance in Interior Zone (day) = 4,2 cd/m² ( traffic = low) Assumed Value for Luminance in Interior Zone (night) = 1 cd/m² (tunnel = part of an unlit road)

Assumed Value for Luminance in Threshold Zone = 150 cd/m² (L20=2500, k=0,06)

Adaptation:55 x 5NA854D1TA1NW (400W)

6 x 5NA854D1SA1NW (250W)22 x 5NA854D1PA1NW (150W)

Interior Zone:48 x 5XA8638HCS5D1 (12500 lm)

The determination of the lighting results is performed on a sales support basis, with great thoroughness, using the documents at our disposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux).A guarantee / warranty / liability for this free calculation is not provided by SITECO. In this respect, we refer to the services of the light planning and engineering office.

The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur.

Guarantee claims for luminaire data are excluded.

Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties.

1 Luminaire data1.1 Siteco, TS 30 S (5NA854D1TA1NW)1.1.1 Data sheet

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 2/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Manufacturer: Siteco

5NA854D1TA1NW tunnel luminaire TS 30 STS 30 S, tunnel luminaire, primary light control with specular reflector, of aluminium, hammer dimple, primaryoptical cover: cover panel, of toughened safety glass, transparent, light emission: direct distribution, primary lightcharacteristic: asymmetric, installation type: surface-mounted, for 1 x HST 400W, superimposed pulse ignitor,control gear: LLCG, parallel p.f. corrected, reducing circuit with relay, without timer, with terminal, 8-pole, max.10mm², mains connection: 230V, AC, 50Hz, luminaire housing, of stainless steel 1.4571, etched and passivated,natural, length: 680 mm, width: 460 mm, height: 168mm, protection rating (complete): IP65, insulation class(complete): insulation class I (protective earthing), certification: CE, impact resistance: IK10, packaging unit: 1piece,

Luminaire dataLuminaire efficiency : 77.9%Luminaire efficacy : 98.68 lm/W

A30 ↓ 100.0% ↑ 0.0% Classification :CIE Flux Codes : 37 73 98 100 78UGR 4H 8H (20%, 50%, 70%)C0 / C90 : 83.3 / 72.4Control gear : LLCGSystem power : 446 WLength : 460 mmWidth : 680 mmHeight : 167 mm

Equipped withQuantity : 1Designation : HST-MF

400W/220 LL(OSRAM)

Power : 400WColour :Luminous flux : 56500 lm

1 Luminaire data1.2 Siteco, TS 30 S (5NA854D1SA1NW)1.2.1 Data sheet

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 3/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Manufacturer: Siteco

5NA854D1SA1NW tunnel luminaire TS 30 STS 30 S, tunnel luminaire, primary light control with specular reflector, of aluminium, hammer dimple, primaryoptical cover: cover panel, of toughened safety glass, transparent, light emission: direct distribution, primary lightcharacteristic: asymmetric, installation type: surface-mounted, for 1 x HST 250W, superimposed pulse ignitor,control gear: LLCG, parallel p.f. corrected, reducing circuit with relay, without timer, with terminal, 8-pole, max.10mm², mains connection: 230V, AC, 50Hz, luminaire housing, of stainless steel 1.4571, etched and passivated,natural, length: 680 mm, width: 460 mm, height: 168mm, protection rating (complete): IP65, insulation class(complete): insulation class I (protective earthing), certification: CE, impact resistance: IK10, packaging unit: 1piece,

Luminaire dataLuminaire efficiency : 74.4%Luminaire efficacy : 86.15 lm/W

A30 ↓ 100.0% ↑ 0.0% Classification :CIE Flux Codes : 39 74 99 100 74UGR 4H 8H (20%, 50%, 70%)C0 / C90 : 81.0 / 70.2Control gear : LLCGSystem power : 285 WLength : 460 mmWidth : 680 mmHeight : 167 mm

Equipped withQuantity : 1Designation : HST-MF

250W/220 LL(OSRAM)

Power : 250WColour :Luminous flux : 33000 lm

1 Luminaire data1.3 Siteco, TS 30 S (5NA854D1PA1NW)1.3.1 Data sheet

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 4/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Manufacturer: Siteco

5NA854D1PA1NW tunnel luminaire TS 30 STS 30 S, tunnel luminaire, primary light control with specular reflector, of aluminium, hammer dimple, primaryoptical cover: cover panel, of toughened safety glass, transparent, light emission: direct distribution, primary lightcharacteristic: asymmetric, installation type: surface-mounted, for 1 x HST 150W, superimposed pulse ignitor,control gear: LLCG, parallel p.f. corrected, reducing circuit with relay, without timer, with terminal, 8-pole, max.10mm², mains connection: 230V, AC, 50Hz, luminaire housing, of stainless steel 1.4571, etched and passivated,natural, length: 680 mm, width: 460 mm, height: 168mm, protection rating (complete): IP65, insulation class(complete): insulation class I (protective earthing), certification: CE, impact resistance: IK10, packaging unit: 1piece,

Luminaire dataLuminaire efficiency : 72.4%Luminaire efficacy : 71.99 lm/W

A30 ↓ 100.0% ↑ 0.0% Classification :CIE Flux Codes : 38 74 98 100 72UGR 4H 8H (20%, 50%, 70%)C0 / C90 : 78.5 / 68.0Control gear : LLCGSystem power : 176 WLength : 460 mmWidth : 680 mmHeight : 167 mm

Equipped withQuantity : 1Designation : HST-MF

150W/220 LL(OSRAM)

Power : 150WColour :Luminous flux : 17500 lm

1 Luminaire data1.4 SiTECO, LED Tunnelleuchte TL21 Midi, (5XA8638HCS5D1)1.4.1 Data sheet

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 5/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Manufacturer: SiTECO

5XA8638HCS5D1 LED Tunnelleuchte TL21 Midi,

Luminaire dataLuminaire efficiency : 100%Luminaire efficacy : 108.7 lm/W

A40 ↓ 100.0% ↑ 0.0% Classification :CIE Flux Codes : 46 83 97 100 100UGR 4H 8H (20%, 50%, 70%)C0 / C90 : 30.0 / 20.7Control gear :System power : 115 WLength : 253 mmWidth : 1100 mmHeight : 131 mm

Equipped withQuantity : 1Designation : LED 5700K /

CRI >= 70Colour :Luminous flux : 12500 lm

2 Tunnel2.1 Description, Tunnel2.1.1 Project data

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 6/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Geometry tunnelLength of the tunnel : 600 mLength of the tunnel (calculation model) : 600 mHeight of the tunnel : 5 m

Width of the lane : 7.5 mNumber of lanes : 2Covering / material : R3, q0 = 0.07Marginal strip right : 1 mMarginal strip left : 1 m

Height of the wall (right) : 2 mCovering / material : diffus 30%

Height of the wall (left) : 2 mCovering / material : diffus 30%

Calculation specificationsSpeed : 80 km/hLength of the threshold zone : 99 mLuminance threshold zone : 150 cd/m²Luminance interior zone : 4.2 cd/m²

2 Tunnel2.1 Description, Tunnel2.1.1 Project data

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 7/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

LDC in useSiteco

1 Order No. : 5NA854D1TA1NWLuminaire name : TS 30 SEquipment : 1 x HST-MF 400W/220 LL (OSRAM) 400W / 56500 lmMaintenance factor: 0.70

2 Order No. : 5NA854D1SA1NWLuminaire name : TS 30 SEquipment : 1 x HST-MF 250W/220 LL (OSRAM) 250W / 33000 lmMaintenance factor: 0.70

3 Order No. : 5NA854D1PA1NWLuminaire name : TS 30 SEquipment : 1 x HST-MF 150W/220 LL (OSRAM) 150W / 17500 lmMaintenance factor: 0.70

SiTECO

2 Tunnel2.1 Description, Tunnel2.1.1 Project data

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 8/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

4 Order No. : 5XA8638HCS5D1Luminaire name : LED Tunnelleuchte TL21 Midi, Equipment : 1 x LED 5700K / CRI >= 70 / 12500 lmMaintenance factor: 0.70

2.1 Description, Tunnel2.1.2 Luminaire list

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 9/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

AdaptationLDC in use

Siteco1 55 Order No. : 5NA854D1TA1NW

Luminaire name : TS 30 SEquipment : 1 x HST-MF 400W/220 LL (OSRAM) 400W / 56500 lmMaintenance factor: 0.70

2 6 Order No. : 5NA854D1SA1NWLuminaire name : TS 30 SEquipment : 1 x HST-MF 250W/220 LL (OSRAM) 250W / 33000 lmMaintenance factor: 0.70

3 22 Order No. : 5NA854D1PA1NWLuminaire name : TS 30 SEquipment : 1 x HST-MF 150W/220 LL (OSRAM) 150W / 17500 lmMaintenance factor: 0.70

Row of luminaires: Adaptation (3.1)Number of luminaires: 83 System power (total): 30.1kWBasic position: x=6.20m y=3.50m, z=4.80m -variable distances-Rotation: z=180.0° C0=0.0° C90=0.0°

Nr. Pos. X [m] Power level Control gr.S1 S2 S3 S4 S5 S6 Int.1 Int.21 6.20 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%2 7.84 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%3 9.48 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%4 11.12 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%5 12.76 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%6 14.40 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%

2.1 Description, Tunnel2.1.2 Luminaire list

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 10/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

7 16.04 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%8 17.68 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%9 19.32 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%

10 20.96 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%11 22.60 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%12 24.24 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%13 25.88 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%14 27.52 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%15 29.16 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%16 30.80 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%17 32.44 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%18 34.08 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%19 35.72 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%20 37.36 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%21 39.00 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%22 40.64 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%23 42.28 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%24 43.92 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%25 45.56 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%26 47.20 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%27 48.84 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%28 50.48 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%29 52.12 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%30 53.76 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%31 55.40 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%32 57.04 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%33 58.68 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%34 60.32 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%35 61.99 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%36 63.69 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%37 65.44 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%38 67.22 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%39 69.05 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%40 70.92 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%41 72.84 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%42 74.82 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%43 76.86 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%44 78.96 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%45 81.13 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%46 83.38 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%47 85.72 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%48 88.16 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%49 90.72 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%50 93.40 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%51 96.24 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%52 99.27 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%53 102.52 400W / 56.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%54 106.05 400W / 56.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%55 109.97 400W / 56.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%56 112.51 250W / 33klm 2 100% 100% 50% 50% 50% 0% 0% 0%57 115.20 250W / 33klm 1 100% 50% 50% 50% 0% 0% 0% 0%58 118.15 250W / 33klm 3 100% 100% 100% 50% 50% 50% 0% 0%59 121.38 250W / 33klm 2 100% 100% 50% 50% 50% 0% 0% 0%60 124.93 250W / 33klm 1 100% 50% 50% 50% 0% 0% 0% 0%61 128.85 250W / 33klm 3 100% 100% 100% 50% 50% 50% 0% 0%

2.1 Description, Tunnel2.1.2 Luminaire list

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 11/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

62 131.16 150W / 17.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%63 133.55 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%64 136.09 150W / 17.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%65 138.78 150W / 17.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%66 141.64 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%67 144.68 150W / 17.5klm 3 100% 100% 100% 50% 50% 50% 0% 0%68 147.93 150W / 17.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%69 151.40 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%70 155.13 150W / 17.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%71 159.12 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%72 163.43 150W / 17.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%73 168.09 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%74 173.13 150W / 17.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%75 178.62 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%76 184.62 150W / 17.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%77 190.62 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%78 196.62 150W / 17.5klm 2 100% 100% 50% 50% 50% 0% 0% 0%79 204.46 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%80 213.31 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%81 223.32 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%82 234.79 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%83 246.79 150W / 17.5klm 1 100% 50% 50% 50% 0% 0% 0% 0%

Innenbel.LDC in use

SiTECO4 Order No. : 5XA8638HCS5D1

Luminaire name : LED Tunnelleuchte TL21 Midi, Equipment : 1 x LED 5700K / CRI >= 70 / 12500 lmMaintenance factor: 0.70

Row of luminaires: Interior (1.1)Number of luminaires: 48 System power (total): 5.5kW (0.60 km)Basic position: x=5.00m y=3.50m, z=4.80m Constant distance: 12.50mRotation: z=0.0° C0=0.0° C90=0.0° Flicker frequency (v=80 km/h): 1.8 Hz

Nr. Pos. X [m] Power level Control gr.S1 S2 S3 S4 S5 S6 Int.1 Int.21 5.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%2 17.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%3 30.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%4 42.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%5 55.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%6 67.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%7 80.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%8 92.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%9 105.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%

2.1 Description, Tunnel2.1.2 Luminaire list

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 12/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

10 117.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%11 130.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%12 142.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%13 155.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%14 167.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%15 180.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%16 192.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%17 205.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%18 217.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%19 230.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%20 242.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%21 255.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%22 267.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%23 280.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%24 292.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%25 305.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%26 317.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%27 330.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%28 342.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%29 355.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%30 367.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%31 380.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%32 392.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%33 405.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%34 417.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%35 430.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%36 442.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%37 455.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%38 467.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%39 480.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%40 492.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%41 505.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%42 517.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%43 530.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%44 542.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%45 555.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%46 567.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%47 580.00 115W / 12.5klm 4 100% 100% 100% 100% 100% 100% 100% 25%48 592.50 115W / 12.5klm 5 100% 100% 100% 100% 100% 100% 100% 25%

2 Tunnel2.2 Calculation results, Tunnel2.2.1 Result overview, S1: 100%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 13/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Regulating step: S1: 100%Adaptation

1: 100%2: 100%3: 100%

Interior4: 100%5: 100%

Einfahrt, Threshold zone (constant)Measuring range: 17.68 m - 34.08 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = -42.32 m; z = 1.50 m dx = 61.17 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 154.73 cd/m²Uo Lmin/Lavg : 0.48Ul Llmin/Llmax: 0.97qc(av) : 0.84 cd/m²/lxqc(min) : 0.50 cd/m²/lxB Max. : 0.04

Wall left (diffus 30%)Lav : 84.87 cd/m²Uo Lmin/Lavg : 0.94

Wall right (diffus 30%)Lav : 96.46 cd/m²Uo Lmin/Lavg : 0.96

y =5.63 m

155.31 cd/m²0.54 0.40.97 0.60.85 cd/m²/lx0.52 cd/m²/lx0.03 0.15

84.87 cd/m²0.94

96.46 cd/m²0.96

IlluminanceRoadwayEm :1792.97 lxUo Emin/Eav : 0.76Wall leftEm : 888.76 lxUo Emin/Eav : 0.94

Wall rightEm :1010.18 lxUo Emin/Eav : 0.96

2 Tunnel2.2 Calculation results, Tunnel2.2.1 Result overview, S1: 100%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 14/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Innen, Interior zoneMeasuring range: 276.20 m - 298.80 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = 216.20 m; z = 1.50 m dx = 61.61 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 4.17 cd/m²Uo Lmin/Lavg : 0.46Ul Llmin/Llmax: 0.79qc(av) : 0.13 cd/m²/lxTI max. Max. : 9.17 %

Wall left (diffus 30%)Lav : 1.99 cd/m²Uo Lmin/Lavg : 0.77

Wall right (diffus 30%)Lav : 2.39 cd/m²Uo Lmin/Lavg : 0.74

y =5.63 m

4.17 cd/m²0.50 0.40.83 0.60.13 cd/m²/lx7.85 %

1.99 cd/m²0.77

2.39 cd/m²0.74

IlluminanceRoadwayEm : 74.60 lxUo Emin/Eav : 0.54Wall leftEm : 20.85 lxUo Emin/Eav : 0.77

Wall rightEm : 25.02 lxUo Emin/Eav : 0.74

Adaptation, Threshold and transition zoneMeasuring range: -1.06 m - 598.71 m Points: nx = 256, ny = 6, nz = 3Observer (starting point coordinate) : x = -85.83 m; z = 1.50 m dx = 85.93 m (moving)

y =1.88 mRoadway (R3, q0 = 0.07)

Wall left (diffus 30%)

Wall right (diffus 30%)

y =5.63 m

qc: The backward reflecion of the road was calculated.

2.2 Calculation results, Tunnel2.2.2 Result overview, S2: 83.3%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 15/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Regulating step: S2: 83.3%Adaptation

1: 50%2: 100%3: 100%

Interior4: 100%5: 100%

Einfahrt, Threshold zone (constant)Measuring range: 17.68 m - 34.08 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = -42.32 m; z = 1.50 m dx = 61.17 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 129.48 cd/m²Uo Lmin/Lavg : 0.48Ul Llmin/Llmax: 0.98qc(av) : 0.81 cd/m²/lxqc(min) : 0.48 cd/m²/lxB Max. : 0.04

Wall left (diffus 30%)Lav : 70.85 cd/m²Uo Lmin/Lavg : 0.94

Wall right (diffus 30%)Lav : 80.48 cd/m²Uo Lmin/Lavg : 0.96

y =5.63 m

129.96 cd/m²0.54 0.40.98 0.60.82 cd/m²/lx0.50 cd/m²/lx0.03 0.15

70.85 cd/m²0.94

80.48 cd/m²0.96

IlluminanceRoadwayEm :1499.43 lxUo Emin/Eav : 0.75Wall leftEm : 741.91 lxUo Emin/Eav : 0.94

Wall rightEm : 842.79 lxUo Emin/Eav : 0.96

2.2 Calculation results, Tunnel2.2.2 Result overview, S2: 83.3%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 16/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Innen, Interior zoneMeasuring range: 276.20 m - 298.80 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = 216.20 m; z = 1.50 m dx = 61.61 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 4.17 cd/m²Uo Lmin/Lavg : 0.46Ul Llmin/Llmax: 0.79qc(av) : 0.13 cd/m²/lxTI max. Max. : 9.17 %

Wall left (diffus 30%)Lav : 1.99 cd/m²Uo Lmin/Lavg : 0.77

Wall right (diffus 30%)Lav : 2.39 cd/m²Uo Lmin/Lavg : 0.74

y =5.63 m

4.17 cd/m²0.50 0.40.83 0.60.13 cd/m²/lx7.85 %

1.99 cd/m²0.77

2.39 cd/m²0.74

IlluminanceRoadwayEm : 74.60 lxUo Emin/Eav : 0.54Wall leftEm : 20.85 lxUo Emin/Eav : 0.77

Wall rightEm : 25.02 lxUo Emin/Eav : 0.74

Adaptation, Threshold and transition zoneMeasuring range: -1.06 m - 598.71 m Points: nx = 256, ny = 6, nz = 3Observer (starting point coordinate) : x = -85.83 m; z = 1.50 m dx = 85.93 m (moving)

y =1.88 mRoadway (R3, q0 = 0.07)

Wall left (diffus 30%)

Wall right (diffus 30%)

y =5.63 m

qc: The backward reflecion of the road was calculated.

2.2 Calculation results, Tunnel2.2.3 Result overview, S3: 66.7%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 17/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Regulating step: S3: 66.7%Adaptation

1: 50%2: 50%3: 100%

Interior4: 100%5: 100%

Einfahrt, Threshold zone (constant)Measuring range: 17.68 m - 34.08 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = -42.32 m; z = 1.50 m dx = 61.17 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 104.51 cd/m²Uo Lmin/Lavg : 0.49Ul Llmin/Llmax: 0.97qc(av) : 0.78 cd/m²/lxqc(min) : 0.46 cd/m²/lxB Max. : 0.04

Wall left (diffus 30%)Lav : 57.48 cd/m²Uo Lmin/Lavg : 0.95

Wall right (diffus 30%)Lav : 65.32 cd/m²Uo Lmin/Lavg : 0.96

y =5.63 m

104.89 cd/m²0.55 0.40.96 0.60.79 cd/m²/lx0.47 cd/m²/lx0.03 0.15

57.48 cd/m²0.95

65.32 cd/m²0.96

IlluminanceRoadwayEm :1217.75 lxUo Emin/Eav : 0.76Wall leftEm : 601.88 lxUo Emin/Eav : 0.95

Wall rightEm : 684.06 lxUo Emin/Eav : 0.96

2.2 Calculation results, Tunnel2.2.3 Result overview, S3: 66.7%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 18/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Innen, Interior zoneMeasuring range: 276.20 m - 298.80 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = 216.20 m; z = 1.50 m dx = 61.61 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 4.17 cd/m²Uo Lmin/Lavg : 0.46Ul Llmin/Llmax: 0.79qc(av) : 0.13 cd/m²/lxTI max. Max. : 9.17 %

Wall left (diffus 30%)Lav : 1.99 cd/m²Uo Lmin/Lavg : 0.77

Wall right (diffus 30%)Lav : 2.39 cd/m²Uo Lmin/Lavg : 0.74

y =5.63 m

4.17 cd/m²0.50 0.40.83 0.60.13 cd/m²/lx7.85 %

1.99 cd/m²0.77

2.39 cd/m²0.74

IlluminanceRoadwayEm : 74.60 lxUo Emin/Eav : 0.54Wall leftEm : 20.84 lxUo Emin/Eav : 0.77

Wall rightEm : 25.02 lxUo Emin/Eav : 0.74

Adaptation, Threshold and transition zoneMeasuring range: -1.06 m - 598.71 m Points: nx = 256, ny = 6, nz = 3Observer (starting point coordinate) : x = -85.83 m; z = 1.50 m dx = 85.93 m (moving)

y =1.88 mRoadway (R3, q0 = 0.07)

Wall left (diffus 30%)

Wall right (diffus 30%)

y =5.63 m

qc: The backward reflecion of the road was calculated.

2.2 Calculation results, Tunnel2.2.4 Result overview, S4: 50%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 19/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Regulating step: S4: 50%Adaptation

1: 50%2: 50%3: 50%

Interior4: 100%5: 100%

Einfahrt, Threshold zone (constant)Measuring range: 17.68 m - 34.08 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = -42.32 m; z = 1.50 m dx = 61.17 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 79.45 cd/m²Uo Lmin/Lavg : 0.48Ul Llmin/Llmax: 0.97qc(av) : 0.73 cd/m²/lxqc(min) : 0.43 cd/m²/lxB Max. : 0.04

Wall left (diffus 30%)Lav : 43.42 cd/m²Uo Lmin/Lavg : 0.94

Wall right (diffus 30%)Lav : 49.42 cd/m²Uo Lmin/Lavg : 0.96

y =5.63 m

79.74 cd/m²0.54 0.40.97 0.60.73 cd/m²/lx0.44 cd/m²/lx0.03 0.15

43.42 cd/m²0.94

49.42 cd/m²0.96

IlluminanceRoadwayEm : 933.98 lxUo Emin/Eav : 0.75Wall leftEm : 454.73 lxUo Emin/Eav : 0.94

Wall rightEm : 517.55 lxUo Emin/Eav : 0.96

2.2 Calculation results, Tunnel2.2.4 Result overview, S4: 50%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 20/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Innen, Interior zoneMeasuring range: 276.20 m - 298.80 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = 216.20 m; z = 1.50 m dx = 61.61 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 4.17 cd/m²Uo Lmin/Lavg : 0.46Ul Llmin/Llmax: 0.79qc(av) : 0.13 cd/m²/lxTI max. Max. : 9.17 %

Wall left (diffus 30%)Lav : 1.99 cd/m²Uo Lmin/Lavg : 0.77

Wall right (diffus 30%)Lav : 2.39 cd/m²Uo Lmin/Lavg : 0.74

y =5.63 m

4.17 cd/m²0.50 0.40.83 0.60.13 cd/m²/lx7.85 %

1.99 cd/m²0.77

2.39 cd/m²0.74

IlluminanceRoadwayEm : 74.60 lxUo Emin/Eav : 0.54Wall leftEm : 20.84 lxUo Emin/Eav : 0.77

Wall rightEm : 25.02 lxUo Emin/Eav : 0.74

Adaptation, Threshold and transition zoneMeasuring range: -1.06 m - 598.71 m Points: nx = 256, ny = 6, nz = 3Observer (starting point coordinate) : x = -85.83 m; z = 1.50 m dx = 85.93 m (moving)

y =1.88 mRoadway (R3, q0 = 0.07)

Wall left (diffus 30%)

Wall right (diffus 30%)

y =5.63 m

qc: The backward reflecion of the road was calculated.

2.2 Calculation results, Tunnel2.2.5 Result overview, S5: 33.3%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 21/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Regulating step: S5: 33.3%Adaptation

1: 0%2: 50%3: 50%

Interior4: 100%5: 100%

Einfahrt, Threshold zone (constant)Measuring range: 17.68 m - 34.08 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = -42.32 m; z = 1.50 m dx = 61.17 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 54.19 cd/m²Uo Lmin/Lavg : 0.47Ul Llmin/Llmax: 0.97qc(av) : 0.64 cd/m²/lxqc(min) : 0.36 cd/m²/lxB Max. : 0.04

Wall left (diffus 30%)Lav : 29.40 cd/m²Uo Lmin/Lavg : 0.92

Wall right (diffus 30%)Lav : 33.44 cd/m²Uo Lmin/Lavg : 0.93

y =5.63 m

54.39 cd/m²0.53 0.40.97 0.60.64 cd/m²/lx0.37 cd/m²/lx0.03 0.15

29.40 cd/m²0.92

33.44 cd/m²0.93

IlluminanceRoadwayEm : 640.43 lxUo Emin/Eav : 0.72Wall leftEm : 307.89 lxUo Emin/Eav : 0.92

Wall rightEm : 350.17 lxUo Emin/Eav : 0.93

2.2 Calculation results, Tunnel2.2.5 Result overview, S5: 33.3%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 22/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Innen, Interior zoneMeasuring range: 276.20 m - 298.80 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = 216.20 m; z = 1.50 m dx = 61.61 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 4.17 cd/m²Uo Lmin/Lavg : 0.46Ul Llmin/Llmax: 0.79qc(av) : 0.13 cd/m²/lxTI max. Max. : 9.17 %

Wall left (diffus 30%)Lav : 1.99 cd/m²Uo Lmin/Lavg : 0.77

Wall right (diffus 30%)Lav : 2.39 cd/m²Uo Lmin/Lavg : 0.74

y =5.63 m

4.17 cd/m²0.50 0.40.83 0.60.13 cd/m²/lx7.85 %

1.99 cd/m²0.77

2.39 cd/m²0.74

IlluminanceRoadwayEm : 74.60 lxUo Emin/Eav : 0.54Wall leftEm : 20.84 lxUo Emin/Eav : 0.77

Wall rightEm : 25.02 lxUo Emin/Eav : 0.74

Adaptation, Threshold and transition zoneMeasuring range: -1.06 m - 598.71 m Points: nx = 256, ny = 6, nz = 3Observer (starting point coordinate) : x = -85.83 m; z = 1.50 m dx = 85.93 m (moving)

y =1.88 mRoadway (R3, q0 = 0.07)

Wall left (diffus 30%)

Wall right (diffus 30%)

y =5.63 m

qc: The backward reflecion of the road was calculated.

2.2 Calculation results, Tunnel2.2.6 Result overview, S6: 16.7%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 23/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Regulating step: S6: 16.7%Adaptation

1: 0%2: 0%3: 50%

Interior4: 100%5: 100%

Einfahrt, Threshold zone (constant)Measuring range: 17.68 m - 34.08 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = -42.32 m; z = 1.50 m dx = 61.17 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 29.23 cd/m²Uo Lmin/Lavg : 0.48Ul Llmin/Llmax: 0.91qc(av) : 0.50 cd/m²/lxqc(min) : 0.27 cd/m²/lxB Max. : 0.04

Wall left (diffus 30%)Lav : 16.02 cd/m²Uo Lmin/Lavg : 0.94

Wall right (diffus 30%)Lav : 18.28 cd/m²Uo Lmin/Lavg : 0.92

y =5.63 m

29.33 cd/m²0.53 0.40.93 0.60.51 cd/m²/lx0.27 cd/m²/lx0.03 0.15

16.02 cd/m²0.94

18.28 cd/m²0.92

IlluminanceRoadwayEm : 358.75 lxUo Emin/Eav : 0.72Wall leftEm : 167.81 lxUo Emin/Eav : 0.94

Wall rightEm : 191.40 lxUo Emin/Eav : 0.92

2.2 Calculation results, Tunnel2.2.6 Result overview, S6: 16.7%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 24/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Innen, Interior zoneMeasuring range: 276.20 m - 298.80 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = 216.20 m; z = 1.50 m dx = 61.61 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 4.17 cd/m²Uo Lmin/Lavg : 0.46Ul Llmin/Llmax: 0.79qc(av) : 0.13 cd/m²/lxTI max. Max. : 9.17 %

Wall left (diffus 30%)Lav : 1.99 cd/m²Uo Lmin/Lavg : 0.77

Wall right (diffus 30%)Lav : 2.39 cd/m²Uo Lmin/Lavg : 0.74

y =5.63 m

4.17 cd/m²0.50 0.40.83 0.60.13 cd/m²/lx7.85 %

1.99 cd/m²0.77

2.39 cd/m²0.74

IlluminanceRoadwayEm : 74.60 lxUo Emin/Eav : 0.54Wall leftEm : 20.84 lxUo Emin/Eav : 0.77

Wall rightEm : 25.01 lxUo Emin/Eav : 0.74

Adaptation, Threshold and transition zoneMeasuring range: -1.06 m - 598.71 m Points: nx = 256, ny = 6, nz = 3Observer (starting point coordinate) : x = -85.83 m; z = 1.50 m dx = 85.93 m (moving)

y =1.88 mRoadway (R3, q0 = 0.07)

Wall left (diffus 30%)

Wall right (diffus 30%)

y =5.63 m

qc: The backward reflecion of the road was calculated.

2.2 Calculation results, Tunnel2.2.7 Result overview, Int.1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 25/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Regulating step: Int.1Adaptation

1: 0%2: 0%3: 0%

Interior4: 100%5: 100%

Innen, Interior zoneMeasuring range: 276.20 m - 298.80 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = 216.20 m; z = 1.50 m dx = 61.61 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 4.17 cd/m²Uo Lmin/Lavg : 0.46Ul Llmin/Llmax: 0.79qc(av) : 0.13 cd/m²/lxTI max. Max. : 9.17 %

Wall left (diffus 30%)Lav : 1.99 cd/m²Uo Lmin/Lavg : 0.77

Wall right (diffus 30%)Lav : 2.39 cd/m²Uo Lmin/Lavg : 0.74

y =5.63 m

4.17 cd/m²0.50 0.40.83 0.60.13 cd/m²/lx7.85 %

1.99 cd/m²0.77

2.39 cd/m²0.74

IlluminanceRoadwayEm : 74.60 lxUo Emin/Eav : 0.54Wall leftEm : 20.84 lxUo Emin/Eav : 0.77

Wall rightEm : 25.01 lxUo Emin/Eav : 0.74

qc: The backward reflecion of the road was calculated.

2.2 Calculation results, Tunnel2.2.8 Result overview, Int.2

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 26/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Regulating step: Int.2Adaptation

1: 0%2: 0%3: 0%

Interior4: 25%5: 25%

Innen, Interior zoneMeasuring range: 276.20 m - 298.80 m Points: nx = 7, ny = 6, nz = 3Observer (starting point coordinate) : x = 216.20 m; z = 1.50 m dx = 61.61 m (fix)

y =1.88 mRoadway (R3, q0 = 0.07)Lav : 1.04 cd/m²Uo Lmin/Lavg : 0.46Ul Llmin/Llmax: 0.79qc(av) : 0.13 cd/m²/lxTI max. Max. : 9.17 %

Wall left (diffus 30%)Lav : 0.50 cd/m²Uo Lmin/Lavg : 0.77

Wall right (diffus 30%)Lav : 0.60 cd/m²Uo Lmin/Lavg : 0.74

y =5.63 m

1.04 cd/m²0.50 0.40.83 0.60.13 cd/m²/lx7.85 %

0.50 cd/m²0.77

0.60 cd/m²0.74

IlluminanceRoadwayEm : 18.65 lxUo Emin/Eav : 0.54Wall leftEm : 5.21 lxUo Emin/Eav : 0.77

Wall rightEm : 6.25 lxUo Emin/Eav : 0.74

qc: The backward reflecion of the road was calculated.

2.2 Calculation results, Tunnel2.2.9 Evolution, Adaptation (L), S1: 100%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 27/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

10

20

30

40

50

60

70

80

90

100

110[%]

20 40 60 80 100 120 140 160 180 200 220 240 260[m]

[cd/m²]150

60

8.4

2.2 Calculation results, Tunnel2.2.10 Evolution, Adaptation (L), S2: 83.3%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 28/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

10

20

30

40

50

60

70

80

90

100

110[%]

20 40 60 80 100 120 140 160 180 200 220 240[m]

[cd/m²]124.95

49.98

8.4

2.2 Calculation results, Tunnel2.2.11 Evolution, Adaptation (L), S3: 66.7%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 29/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

10

20

30

40

50

60

70

80

90

100

110[%]

20 40 60 80 100 120 140 160 180 200 220[m]

[cd/m²]100.05

40.02

8.44.2

2.2 Calculation results, Tunnel2.2.12 Evolution, Adaptation (L), S4: 50%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 30/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

10

20

30

40

50

60

70

80

90

100

110[%]

20 40 60 80 100 120 140 160 180 200[m]

[cd/m²]75

30

8.44.2

2.2 Calculation results, Tunnel2.2.13 Evolution, Adaptation (L), S5: 33.3%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 31/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

10

20

30

40

50

60

70

80

90

100

110

[%]

20 40 60 80 100 120 140 160 [m]

[cd/m²]49.95

19.98

8.4

4.2

max: 56.7 cd/m²

2.2 Calculation results, Tunnel2.2.14 Evolution, Adaptation (L), S6: 16.7%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 32/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

10

20

30

40

50

60

70

80

90

100

110

120

[%]

20 40 60 80 100 120 140[m]

[cd/m²]25.05

10.028.4

4.2

max: 31.2 cd/m²

2 Tunnel2.3 Calculation results, Tunnel2.3.1 Table, Einfahrt (L), S1: 100%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 33/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Observer location 1 : x = -42.3, y = 1.88, z = 1.5 (dx = 61.17)Average luminance Lav : 155 cd/m²Minimum luminance Lmin : 74.9 cd/m²Overall uniformity Uo Lmin/Lm : 0.48Longitudinal uniformity UI Llmin/Llmax : 0.97Average contrast revealing coefficient Lr/Ev (av) : 0.844Minimum contrast revealing coefficient Lr/Ev (min) : 0.502

qc: The backward reflecion of the road was calculated.

101 103 102 103 104 102 105

170 173 172 172 174 169 173

256 261 [262] 259 [262] 256 261

189 195 196 196 199 194 200

118 121 122 121 125 121 125

(75) 76 76 76 78 76 78

18.85 21.19 23.54 25.88 28.22 30.57 32.91 [m]

0.63

1.88

3.13

4.38

5.63

6.88[m]

2.3 Calculation results, Tunnel2.3.2 Table, Einfahrt (E), S1: 100%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 34/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Height of the reference plane : 0.00 mAverage illuminance Eav : 1790 lxMinimum illuminance Emin : 1360 lxMaximum illuminance Emax : 2190 lxUniformity Uo min/average : 1 : 1.32 (0.76)Diversity Ud min/max : 1 : 1.61 (0.62)

1520 1560 1530 1540 1610 1540 1610

1870 1940 1910 1890 2020 1870 1990

1980 2080 2090 2020 [2190] 1980 2140

1940 2050 2030 1990 2150 1950 2110

1740 1800 1820 1750 1880 1730 1840

(1360) 1380 (1360) (1360) 1410 (1360) 1410

18.85 21.19 23.54 25.88 28.22 30.57 32.91 [m]Illuminance [lx]

0.63

1.88

3.13

4.38

5.63

6.88[m]

2.3 Calculation results, Tunnel2.3.3 Table, Einfahrt (Ev, West (270°)), S1: 100%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 35/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Vertical illuminanceHeight of the reference plane : 0.10 mfrom direction : West (270°)Average illuminance Eav : 179 lxMinimum illuminance Emin : 126 lxMaximum illuminance Emax : 242 lxUniformity Uo min/average : 1 : 1.42 (0.71)Diversity Ud min/max : 1 : 1.91 (0.52)

145 170 162 147 155 143 178

178 218 203 175 189 168 226

184 235 221 183 201 173 [242]

180 229 213 180 198 171 238

163 196 191 161 173 153 203

132 149 146 132 140 (126) 156

18.85 21.19 23.54 25.88 28.22 30.57 32.91 [m]

0.63

1.88

3.13

4.38

5.63

6.88[m]

2.3 Calculation results, Tunnel2.3.4 Table, Einfahrt (E), Wall right, S1: 100%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 36/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Average illuminance Eav : 1010 lxMinimum illuminance Emin : 966 lxMaximum illuminance Emax : 1050 lxUniformity Uo min/average : 1 : 1.05 (0.96)Diversity Ud min/max : 1 : 1.09 (0.92)

985 (966) 983 (966) 994 972 987

[1050] 1040 1040 1040 [1050] [1050] [1050]

999 1010 988 1010 998 1020 997

18.85 21.19 23.54 25.88 28.22 30.57 32.91 [m]Illuminance [lx]

0.33

1.00

1.67[m]

2.3 Calculation results, Tunnel2.3.5 Table, Einfahrt (L), Wall right, S1: 100%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 37/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Observer location 1 : x = -42.3, y = 1.88, z = 1.5 (dx = 61.17)Average luminance Lav : 96.5 cd/m²Minimum luminance Lmin : 92.2 cd/m²Overall uniformity Uo Lmin/Lm : 0.96Longitudinal uniformity UI Llmin/Llmax : 0.99 (1.00m)

94 (92) 94 (92) 95 93 94

100 100 100 100 [101] [101] 100

95 96 94 97 95 97 95

18.85 21.19 23.54 25.88 28.22 30.57 32.91 [m]

0.33

1.00

1.67[m]

2.3 Calculation results, Tunnel2.3.6 Table, Einfahrt (E), Wall left, S1: 100%

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 38/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Average illuminance Eav : 889 lxMinimum illuminance Emin : 835 lxMaximum illuminance Emax : 931 lxUniformity Uo min/average : 1 : 1.06 (0.94)Diversity Ud min/max : 1 : 1.12 (0.9)

893 886 896 884 904 889 899

920 930 920 930 929 [931] 929

839 852 (835) 853 843 857 843

18.85 21.19 23.54 25.88 28.22 30.57 32.91 [m]Illuminance [lx]

0.33

1.00

1.67[m]

2.3 Calculation results, Tunnel2.3.7 Table, Einfahrt (L), Wall left, S1: 100%, Obs. 1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 39/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Observer location 1 : x = -42.3, y = 1.88, z = 1.5 (dx = 61.17)Average luminance Lav : 84.9 cd/m²Minimum luminance Lmin : 79.7 cd/m²Overall uniformity Uo Lmin/Lm : 0.94Longitudinal uniformity UI Llmin/Llmax : 0.99 (1.00m)

85.2 84.6 85.6 84.4 86.3 84.9 85.8

87.9 88.8 87.9 88.8 88.8 [88.9] 88.7

80.1 81.4 (79.7) 81.5 80.5 81.9 80.5

18.85 21.19 23.54 25.88 28.22 30.57 32.91 [m]

0.33

1.00

1.67[m]

2 Tunnel2.4 Calculation results, Tunnel2.4.1 Table, Innen (E), Int.1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 40/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Height of the reference plane : 0.00 mAverage illuminance Eav : 75 lxMinimum illuminance Emin : 40 lxMaximum illuminance Emax : 100 lxUniformity Uo min/average : 1 : 1.86 (0.54)Diversity Ud min/max : 1 : 2.5 (0.4)

63 66 53 49 65 65 51

92 90 76 71 92 92 73

[100] 96 89 81 98 97 84

99 95 86 79 98 97 81

82 82 67 63 83 83 64

50 53 42 (40) 52 53 41

277.81 281.04 284.27 287.50 290.73 293.96 297.19 [m]Illuminance [lx]

0.63

1.88

3.13

4.38

5.63

6.88[m]

2.4 Calculation results, Tunnel2.4.2 Table, Innen (Ev, West (270°)), Int.1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 41/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Vertical illuminanceHeight of the reference plane : 0.10 mfrom direction : West (270°)Average illuminance Eav : 35.5 lxMinimum illuminance Emin : 14.8 lxMaximum illuminance Emax : 73 lxUniformity Uo min/average : 1 : 2.4 (0.42)Diversity Ud min/max : 1 : 4.95 (0.2)

17.6 24.4 41.5 28.5 16.6 28.7 40.6

21.6 32.2 62.2 38.5 20.1 39.3 60.4

23.2 34 [73] 43.7 21.4 41.6 70.5

22.8 33.9 70.2 42.4 21.1 41.5 67.9

20.1 29.6 54.4 34.7 18.7 35.7 53.2

15.6 20.5 32.9 24.1 (14.8) 23.6 32.4

277.81 281.04 284.27 287.50 290.73 293.96 297.19 [m]

0.63

1.88

3.13

4.38

5.63

6.88[m]

2.4 Calculation results, Tunnel2.4.3 Table, Innen (E), Wall right, Int.1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 42/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Average illuminance Eav : 25 lxMinimum illuminance Emin : 18.5 lxMaximum illuminance Emax : 30.5 lxUniformity Uo min/average : 1 : 1.35 (0.74)Diversity Ud min/max : 1 : 1.65 (0.61)

27.6 29.9 23.1 21.9 28.7 29.3 22.4

27.7 [30.5] 22.5 21.3 28.9 29.6 21.7

24.5 27 19.7 (18.5) 25.6 26.2 18.9

277.81 281.04 284.27 287.50 290.73 293.96 297.19 [m]Illuminance [lx]

0.33

1.00

1.67[m]

2.4 Calculation results, Tunnel2.4.4 Table, Innen (E), Wall left, Int.1

ObjectInstallationProject numberDate

: Tunnel: Adaptation TS30S; Interior Zone TL 21: Sample projection: 08/2014

Siteco Beleuchtungstechnik GmbH - AN OSRAM BUSINESSPage 43/43Mustertunnel_CIE 88_2004_Siteco_Light_Consulting_EN

Average illuminance Eav : 20.8 lxMinimum illuminance Emin : 16.1 lxMaximum illuminance Emax : 24.8 lxUniformity Uo min/average : 1 : 1.29 (0.77)Diversity Ud min/max : 1 : 1.54 (0.65)

23 [24.8] 19.6 18.8 23.8 24.2 19.2

22.7 24.6 19 18.3 23.5 24 18.6

20.2 21.9 16.8 (16.1) 20.9 21.4 16.4

277.81 281.04 284.27 287.50 290.73 293.96 297.19 [m]Illuminance [lx]

0.33

1.00

1.67[m]