MultiLoad Modbus Mapping - Amazon S3

118
MultiLoad II Modbus Mapping Including: MultiLoad II MultiLoad II SMP MultiLoad II SCS Part # 6017 Firmware Version 4.33.08 Dec 2020

Transcript of MultiLoad Modbus Mapping - Amazon S3

Page 1: MultiLoad Modbus Mapping - Amazon S3

MultiLoad II

Modbus Mapping Including:

MultiLoad II

MultiLoad II SMP

MultiLoad II SCS

Part # 6017

Firmware Version 4.33.08

Dec 2020

Page 2: MultiLoad Modbus Mapping - Amazon S3

2

Copyright Notice

Copyright © 2006 – 2020 Toptech Systems, Inc. The information contained in this document is proprietary and confidential. No part of this document may be copied, reproduc ed, or transmitted in any medium without the express written permission of Toptech Systems, Inc.

Disclaimer

Toptech Systems assumes no responsibility for damages resulting from installation or use of its products. Toptech Systems wi ll not be liable for any claims of damage, lost data, or lost time as a result of using its products.

Logos are registered trademarks of Toptech Systems, Inc.

Copyright © 2007-2020 Toptech Systems, Inc. All Rights Reserved.

Page 3: MultiLoad Modbus Mapping - Amazon S3

i

Table of Contents

Chapter 1 Getting Started .......................................................... 6

Register Numbering ................................................................................. 6

Data Types............................................................................................... 6

1.2.1 Configuration Data Types ......................................................................................6

ASCII Table.............................................................................................. 7

Protocol Selection .................................................................................... 8

Chapter 2 Protocol Specification ............................................ 9

Modbus RTU protocol .............................................................................. 9

2.1.1 Read Holding Registers (fn=3) ...............................................................................9

2.1.2 Write Single Registers (fn=6) ............................................................................... 10

2.1.3 Loopback/Maintenance (fn=8) ............................................................................. 10

2.1.4 Preset Multiple Registers (fn=16) ......................................................................... 10

2.1.5 Error Responses (fn= +128) ................................................................................ 11

Modbus TCP-IP protocol ........................................................................ 11

2.2.1 Read Holding Registers (fn=3) ............................................................................. 12

2.2.2 Write Single Registers (fn=6) ............................................................................... 13

2.2.3 Loopback/Maintenance (fn=8) ............................................................................. 13

2.2.4 Preset Multiple Registers (fn=16) ......................................................................... 13

2.2.5 Error Responses (fn= +128) ................................................................................ 14

Extended Service Registers ................................................................... 14

Chapter 3 Information/Definition Registers ....................... 16

MultiLoad Information Registers ............................................................ 16

Communication Registers ...................................................................... 16

BOL Registers ........................................................................................ 16

Page 4: MultiLoad Modbus Mapping - Amazon S3

2

Hazard Registers ................................................................................... 18

Product Registers .................................................................................. 19

Driver Database Registers ..................................................................... 20

GPS Site Database Definitions .............................................................. 20

Bilingual Message Support .................................................................... 21

Log Message Registers ......................................................................... 21

Transaction Registers .......................................................................... 21

3.10.1 Transaction Register Configuration .................................................................... 21

3.10.2 Transaction Header Registers ........................................................................... 21

3.10.3 Transaction Detail Registers .............................................................................. 22

Custom Logic Registers....................................................................... 23

Chapter 4 Configuration Registers ....................................... 24

Configuration Data Types ...................................................................... 24

Configuration Indexing ........................................................................... 33

RCU Level Configuration Registers ....................................................... 34

Bay Level Configuration Registers ......................................................... 36

Preset Configuration Registers .............................................................. 37

Component Configuration Registers ...................................................... 41

Additive Configuration Registers ............................................................ 44

Chapter 5 Real -Time Registers ............................................. 47

Real-Time Totalizer Registers ................................................................ 47

5.1.1 Real-Time Preset Gross Totalizer ........................................................................ 47

5.1.2 Real-Time Meter Gross Totalizer ......................................................................... 47

5.1.3 Real-Time Component Gross Totalizer ................................................................ 49

5.1.4 Real-Time Additive Gross Totalizer ...................................................................... 51

5.1.5 Real-Time Preset Net Totalizer ............................................................................ 56

5.1.6 Real-Time Component Net Totalizer .................................................................... 57

Page 5: MultiLoad Modbus Mapping - Amazon S3

3

5.1.7 Real-Time Preset Mass Totalizer ......................................................................... 59

5.1.8 Real-Time Component Mass Totalizer ................................................................. 59

Real-Time Value Registers .................................................................... 62

5.2.1 Preset quantity in whole units .............................................................................. 62

5.2.2 Preset Delivered Gross Quantity in Whole Units .................................................. 62

5.2.3 Preset Delivered Net Quantity in Whole Units ...................................................... 63

5.2.4 Preset Batch Average Temp in Tenths or Hundredths .......................................... 63

5.2.5 Batch Average Pressure in Tenths or Hundredths ................................................ 63

5.2.6 Preset Batch Average Density/Relative Density/Gravity ....................................... 64

5.2.7 Preset Gross Flow Rate in Whole Units ............................................................... 64

5.2.8 Meter Delivered Gross Quantity in Whole Units ................................................... 65

5.2.9 Meter Gross Flow Rate in Whole Units ................................................................ 66

5.2.10 Component Delivered Gross Quantity in Whole Units......................................... 68

5.2.11 Component Delivered Net Quantity in Whole Units ............................................ 70

5.2.12 Component Batch Average Temp in Tenths or Hundredths ................................ 73

5.2.13 Component Batch Average Pressure in Tenths or Hundredths ........................... 75

5.2.14 Component Batch Average Density/Relative Density/Gravity ............................. 78

5.2.15 Component Current Temp in Hundredths ........................................................... 80

5.2.16 Component Current Pressure in Hundredths ...................................................... 83

5.2.17 Component Current Density in Tenths ............................................................... 85

5.2.18 Additive Delivered Quantity in Thousands .......................................................... 87

5.2.19 Component Current Relative Density in Ten Thousands .................................... 92

5.2.20 Component Current BSW Hund ......................................................................... 95

5.2.21 Component Current API Gravity Tenths ............................................................. 97

5.2.22 Component Current Mass Delivered ................................................................ 100

Chapter 6 Alarm Registers .................................................... 101

Alarm Messages .................................................................................. 101

Page 6: MultiLoad Modbus Mapping - Amazon S3

4

6.1.1 Bay Alarm Messages ......................................................................................... 101

6.1.2 Preset Alarm Messages ..................................................................................... 101

6.1.3 Meter Alarm Messages ...................................................................................... 102

6.1.4 Component Alarm Messages ............................................................................. 102

6.1.5 Additive Alarm Messages .................................................................................. 102

Trip Preset Alarms ............................................................................... 102

Request Alarms ................................................................................... 103

6.3.1 Request Preset Alarms ...................................................................................... 103

6.3.2 Request Bay Alarms .......................................................................................... 103

6.3.3 Request Component Alarms .............................................................................. 103

6.3.4 Request Meter Alarms ....................................................................................... 106

6.3.5 Request Additive Alarms ................................................................................... 107

Chapter 7 Preset Status Registers ..................................... 113

Preset State ......................................................................................... 113

Preset Status ....................................................................................... 113

State/Status Registers ......................................................................... 114

Start Preset Flow ................................................................................. 114

Stop Preset Flow .................................................................................. 114

Page 7: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

5

Overview

This document is designed to guide users through the available Modbus registers within the MultiLoad. It will help users quickly setup Modbus communication with the MultiLoad to reference status and value register addresses and configurable details.

The following table provides an information map to the material available in this guide.

Chapter Topics Covered

1.Getting Started Modbus Register numbering, data types and communication.

2.Protocol Specification Protocol used to reference Modbus registers and return information.

3.Information/Definition Registers Definitions of Modbus register addresses, data type, read/write permissions, min/max value and preset/meter/component/additive assignment.

4.Real-Time Registers Addresses of real-time totalizers and value registers.

5.Alarm Registers Addresses of preset, meter, component and additive registers.

6.Preset Status Addresses of preset state, status and flow.

The following keys make it easier to find the information you need in this guide:

ICON KEY

Important information to enhance understanding and make better use of the product.

See MultiLoad Communications Manual.

Note that this guide covers MultiLoad II Modbus Mapping information only. For information about base MultiLoad firmware please consult the MultiLoad II User Guide. For information about wiring other models please consult the respecetive Installation Guides. For information about the MultiLoad register interface and Modbus communication, please reference the MultiLoad II Communication Guide. Updated versions of all manuals, including this one, are available on our website at http://www.toptech.com.

Page 8: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

6

Chapter 1 Getting Started

Before getting started, it is good to know the standard Modbus connection equipment, communication configuration and data type information. This topic also provides some basic communications concepts, as well as Toptech's recommendations for achieving optimum performance. Understand the format type that is being used and their charactersistics as well as the ASCII codes.

Host communication can occur via multi-dropped RS-232/RS-485 serial on COM 1 or Ethernet 10/100 socket communication on port 7734. Port 7735 supports SSL encryption (TLS v1.2 only for security reasons) and can be enabled via the network setup screen.

Register Numbering

Modbus registers start at 0 and extend to 13024. Modbus registers are either 16-bit or 32-bit depending on the data field it represents and 32-bit modbus registers are evenly addressed. When referencing a preset, meter component or meter, the modbus registers are incremented based on the max quantity available within a MultiLoad configuration.

Data Types

There are six different data types for Modbus registers shown in the table below. Char means a character value based on the ASCII value seen in Table 1.3. Integer data types include signed and unsigned. The max for a 16-bit register is 65,535 and 4,294,967,296 for a 32-bit register. However, most MultiLoad registers maximum values are 1,000,000,000 before they roll over.

Data Type Description Min Value Max Value

char Numerical 48 57

char Alphabetical 32 122

uint unsigned integer 0 65535

int signed integer -32768 32767

u long int unsigned long int 0 4294967295

perc percent 0.00% 100.00%

1.2.1 Configuration Data Types

These data types are represent in the configuration modbus registers as implied decimals.

Chapter

1

Page 9: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

7

Data Type Description

signed div 10 Positive or negative value with tenths place of a decimal

signed div 100 Positive or negative value hundreths place of a decimal

unsigned div 100 Value with hundreths place of a decimal

unsigned div 1000 Value with thousandsths place of a decimal

ASCII Table

Characters in MultiLoad modbus are represented by their ASCII Decimal value. For example, A=65 a=97

Decimal Char Decimal Char Decimal Char

32 [Space] 63 ? 94 ^

33 ! 64 @ 95 _

34 " 65 A 96 `

35 # 66 B 97 a

36 $ 67 C 98 b

37 % 68 D 99 c

38 & 69 E 100 d

39 ‘ 70 F 101 e

40 ( 71 G 102 f

41 ) 72 H 103 g

42 * 73 I 104 h

43 + 74 J 105 i

44 , 75 K 106 j

45 - 76 L 107 k

46 . 77 M 108 l

47 / 78 N 109 m

48 0 79 O 110 n

49 1 80 P 111 o

50 2 81 Q 112 p

51 3 82 R 113 q

52 4 83 S 114 r

53 5 84 T 115 s

54 6 85 U 116 t

55 7 86 V 117 u

56 8 87 W 118 v

57 9 88 X 119 w

58 : 89 Y 120 x

59 ; 90 Z 121 y

60 < 91 [ 122 z

61 = 92 \

62 > 93 ]

Page 10: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

8

Protocol Selection

See MultiLoad Communications Manual for more information on Protocol Selection.

Page 11: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

9

Chapter 2 Protocol Specification

Modbus RTU protocol

The Modbus-RTU protocol has been implemented to be as compatible as possible with the original published Modicon Modbus-RTU standard. Note: The Modbus protocol allows parameter register access only as defined by the explicit mapping in this manual. To send the ASCII commands (R000, T`A, MAM, MRS, etc.) that are handled by the other three protocols; the Modbus Extended Services registers must be used.

Using the Modbus protocol, MultiLoad accepts data in the following format:

Quiet Time ADR FN ... CRC1 CRC2 Quiet Time

Modbus-RTU protocol messages are framed by a quiet time of three and one-half characters. ADR is binary character of the address of the MultiLoad, typically 0x01. Fn is the Modbus function. Functions implemented are as follows. The formal specification of Modbus lists the starting Holding Register address as 40001. The Modbus Holding Register functions (Fn 3, 6 and 16) all have an implied 4XXXX reference. Referencing Holding Register 40001 is addressed as register 0000 in the register address field in the message for fn 3, 6 and 16.

Since Modbus addressing has been implemented in various ways over the years, to avoid confusion in this manual, the Modbus Holding Register addresses listed are the value in the register address field in the message. If it is necessary to know the formal Modbus Holding Register address, simply add 40001 to the register addresses listed in the manual.

2.1.1 Read Holding Registers (fn=3)

Note: Both Modbus registers MUST be read at the same time when reading 32-bit values.

Tx:

Quiet Time ADR FN=3 Start

Register MSB

Start Register

LSB

Number Of

Registers MSB

Number of Registers

LSB CRC1 CRC2 Quiet Time

Rx:

Quiet Time

ADR FN=3

(+128 if error)

Byte Count

1st Register

MSB

1st Register

LSB

Next Register

MSB

Next Register

MSB … CRC1 CRC2

Quiet Time

Chapter

2

Page 12: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

10

2.1.2 Write Single Registers (fn=6)

Note: cannot be used for 32-bit registers.

Tx:

Quiet Time ADR FN=6 Start

Register MSB

Start Register

LSB

Register MSB

Register LSB

CRC1 CRC2 Quiet Time

Rx:

Quiet Time ADR FN=6

(+128 if error)

Start Register

MSB

Start Register

LSB

Register MSB

Register LSB

CRC1 CRC2 Quiet Time

2.1.3 Loopback/Maintenance (fn=8)

Note: only loopback of command supported.

Tx:

Quiet Time ADR FN=8 Diagnostic Code MSB

Diagnostic Code LSB

Data MSB Data LSB CRC1 CRC2 Quiet Time

Rx:

Quiet Time ADR FN=8 Diagnostic Code MSB

Diagnostic Code LSB

Data MSB Data LSB CRC1 CRC2 Quiet Time

2.1.4 Preset Multiple Registers (fn=16)

Note: Both Modbus registers MUST be written at the same time when writing 32-bit values.

Tx:

Quiet Time

ADR FN=16 Start

Register MSB

Start Register

LSB

Number

Of Registers

MSB

Number of

Registers LSB

Byte Count

1st Register

MSB

1st Register

LSB

Next Register

MSB

Next Register

MSB … CRC1 CRC2

Quiet Time

Rx:

Page 13: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

11

Quiet Time ADR

FN=16

(+128 if error)

Start Register

MSB

Start Register

LSB

Number

Of Registers

MSB

Number of

Registers LSB

CRC1 CRC2 Quiet Time

2.1.5 Error Responses (fn= +128)

Rx:

Quiet Time ADR FN+128 Error

Subcode CRC2 CRC1

Error Sub codes are:

1 = Invalid Function Code indicates that the use of an invalid or unimplemented function has been attempted.

2 = Invalid Address Field indicates that a read or write was made to an invalid address. Can also indicate that a read or write to a single register of a 32-bit value has been attempted.

3 = Invalid Data Field indicates that an attempt to write an invalid value to a register has occurred. This error code will also be returned if an attempt is made to change a value under Weights and Measures control without with W&M switch being in the active state.

4 = Query Processing Failure. This code is not returned.

Modbus TCP-IP protocol

The Modbus-TCP/IP protocol has been implemented to be as compatible as possible with the original published Modbus-TCP/IP standard v1.0b.

Note: The Modbus protocol allows parameter register access only as defined by the explicit mapping in this manual. To send the ASCII commands (R000, T`A, MAM, MRS, etc.) that are handled by the other three protocols; the Modbus Extended Services registers must be used.

Using the Modbus TCP/IP protocol, MultiLoad accepts data in the following format:

MBAP FN DATA

Modbus-TCP/IP protocol messages are framed by a MBAP-Header.

Fields Length Description Client Server

Transaction Identifier 2 Bytes Identification of a MODBUS Request/ Response transaction.

Initialized by the client Recopied by the server from the received request

Protocol Identifier 2 Bytes 0 = Modbus Protocol Initialized by the client Recopied by the server from the received request

Page 14: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

12

Fields Length Description Client Server

Length 2 Bytes Number of following bytes

Initialized by the client (request)

Initialized by the server (Response)

Unit Identifier 1 Byte Identification of a remote slave connected on a serial line or on other buses

Initialized by the client Recopied by the server from the received request

The header is 7 bytes long:

Transaction Identifier - It is used for transaction pairing, the MODBUS server copies in the response the transaction identifier of the request.

Protocol Identifier – It is used for intra-system multiplexing. The MODBUS protocol is identified by the value 0.

Length - The length field is a byte count of the following fields, including the Unit Identifier and data fields.

Unit Identifier – This field is used for intra-system routing purpose. It is typically used to communicate to a MODBUS+ or a MODBUS serial line slave through a gateway between an Ethernet TCP-IP network and a MODBUS serial line. This field is set by the MODBUS Client in the request and must be returned with the same value in the response by the server.

All MODBUS/TCP ADU are sent via TCP to registered port 502.

Remark: the different fields are encoded in Big-endian.

Fn is the Modbus function. Functions implemented are as follows.

The formal specification of Modbus lists the starting Holding Register address as 40001. The Modbus Holding Register functions (Fn 3, 6 and 16) all have an implied 4XXXX reference. Referencing Holding Register 40001 is addressed as register 0000 in the register address field in the message for fn 3, 6 and 16.

Since Modbus addressing has been implemented in various ways over the years, to avoid confusion in this manual, the Modbus Holding Register addresses listed are the value in the register address field in the message. If it is necessary to know the formal Modbus Holding Register address, simply add 40001 to the register addresses listed in the manual.

2.2.1 Read Holding Registers (fn=3)

Note: Both Modbus registers MUST be read at the same time when reading 32-bit values.

Tx:

MBAP FN=3 Start

Register MSB

Start Register

LSB

Number

Of Registers

MSB

Number of

Registers LSB

Page 15: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

13

Rx:

MBAP

FN=3

(+128 if error)

Byte Count

1st Register

MSB

1st Register

LSB

Next Register

MSB

Next Register

MSB …

2.2.2 Write Single Registers (fn=6)

Note: cannot be used for 32-bit registers.

Tx:

MBAP FN=6 Start

Register MSB

Start Register

LSB

Register

MSB

Register

LSB

Rx:

MBAP

FN=6

(+128 if error)

Start Register

MSB

Start Register

LSB

Register

MSB

Register

LSB

2.2.3 Loopback/Maintenance (fn=8)

Note: only loopback of command supported.

Tx:

MBAP FN=8 Diagnostic Code MSB

Diagnostic Code LSB

Data MSB Data LSB

Rx:

MBAP FN=8 Diagnostic Code MSB

Diagnostic Code LSB

Data MSB Data LSB

2.2.4 Preset Multiple Registers (fn=16)

Note: Both Modbus registers MUST be written at the same time when writing 32-bit values.

Tx:

MBAP FN=16 Start

Register MSB

Start Register

LSB

Number

Of Registers

MSB

Number of

Registers LSB

Byte Count

1st Register

MSB

1st Register

LSB

Next Register

MSB

Next Register

MSB …

Page 16: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

14

Rx:

MBAP

FN=16

(+128 if error)

Start Register

MSB

Start Register

LSB

Number

Of Registers

MSB

Number of

Registers LSB

2.2.5 Error Responses (fn= +128)

Rx:

MBAP FN+128 Error

Subcode

Error Sub codes are:

1 = Invalid Function Code indicates that the use of an invalid or unimplemented function has been attempted.

2 = Invalid Address Field indicates that a read or write was made to an invalid address. Can also indicate that a read or write to a single register of a 32-bit value has been attempted.

3 = Invalid Data Field indicates that an attempt to write an invalid value to a register has occurred. This error code will also be returned if an attempt is made to change a value under Weights and Measures control without with W&M switch being in the active state.

4 = Query Processing Failure. This code is not returned.

Extended Service Registers

Not all commands native to the MultiLoad II have corresponding mapping to Modbus registers. The Extended Services register was implemented as a way to support sending and receiving native Multiload II commands across the Modbus RTU interface. Any native command listed can be sent to the MultiLoad via the extended Services Register.

Modbus Registers: Write Holding Register=9000, Len=1, 16-Bit Integer (Command Length) Write Holding Register=9001, Max Len=999, Characters (Command Text) Read Holding Register=9000, Len=2, 32-Bit Integer (Reply Length) Read Holding Register=9001, Max Len=999, Characters (Reply Text)

Perform the following operations to use of the Extended Services Register: 1. Write the Command Length into the Holding Register 9000 (max value of 999 characters).

2. Write the Command Text into the Holding Register 9001 (max length of 999).

3. Command will execute when the final character of the Command Text is written (9001+Command Length-1).

4. Read the Reply Length from the Holding Register 9000 (max value of 999 characters).

5. Read the Reply Text from the Holding Register 9001 (max length of 999).

Page 17: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

15

Steps 1 & 2 can be done with a single Modbus Function 16.

Steps 4 & 5 can be done with a single Modbus Function 3.

Page 18: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

16

Chapter 3 Information/Definition Registers

This chapter outlines the information and definition register available in the MultiLoad.

MultiLoad Information Registers

Register Length Description Read/Write Data Type Min Value Max Value

0 35 Product Name and Revision Read char 32 122

35 12 Date and Time Read/Write char 32 122

178 40 Terminal SPLC Code Read/Write char 48 57

218 25 Terminal Name Read/Write char 32 122

Communication Registers

Register Length Description Read/Write Data Type Min Value Max Value

47 1 FCM Com Poll Rate Read uint 0 65535

50 2 Ethernet IP Address Read/Write uint 0 65535

52 2 Ethernet IP Mask Read/Write uint 0 65535

54 2 Ethernet IP Gateway Read/Write uint 0 65535

56 40 Ethernet IP Host Read/Write uint 0 65535

243 6 COM Port 1 Config Parameters Read/Write char 48 57

249 6 COM Port 2 Config Parameters Read/Write char 48 57

255 6 COM Port 3 Config Parameters Read/Write char 48 57

BOL Registers

Register Length Description Read/Write Data Type Min Value Max Value

48 1 Current BOL Number Read uint 0 65535

350 1 BOL Line For Position Read/Write uint 0 65535

351 1 BOL Position Read/Write uint 0 65535

352 1 BOL Line For Driver Read/Write uint 0 65535

353 1 BOL Position For Dirver Read/Write uint 0 65535

354 1 Company ID Line Read/Write uint 0 65535

355 1 Company ID Pos Read/Write uint 0 65535

356 1 Load Date Line Read/Write uint 0 65535

357 1 Load Date Position Read/Write uint 0 65535

Chapter

3

Page 19: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

17

Register Length Description Read/Write Data Type Min Value Max Value

358 1 Load Start Time Line Read/Write uint 0 65535

359 1 Load Start Time Position Read/Write uint 0 65535

360 1 Load End Time Line Read/Write uint 0 65535

361 1 Load End Time Position Read/Write uint 0 65535

362 1 Corrected To Line Read/Write uint 0 65535

363 1 Corrected To Position Read/Write uint 0 65535

364 1 Hazard Field Line Read/Write uint 0 65535

365 1 Hazard Field Position Read/Write uint 0 65535

366 1 Product Line Read/Write uint 0 65535

367 1 Product Code Position Read/Write uint 0 65535

368 1 Product Position Read/Write uint 0 65535

369 1 Gross Volume Position Read/Write uint 0 65535

370 1 Net Volume Position Read/Write uint 0 65535

371 1 Temperature Position Read/Write uint 0 65535

372 1 Meter/Preset Number Position Read/Write uint 0 65535

373 1 Gravity Position Read/Write uint 0 65535

374 1 Pressure Position Read/Write uint 0 65535

375 1 Alarm Position Read/Write uint 0 65535

376 1 Total Gross BOL Position Read/Write uint 0 65535

377 1 Total Gross BOL Line Read/Write uint 0 65535

378 1 Total Net BOL Position Read/Write uint 0 65535

379 1 Total Net BOL Line Read/Write uint 0 65535

380 1 Base Product 1 Totalizer Position Read/Write uint 0 65535

381 1 Base Product 1 Totalizer Line Read/Write uint 0 65535

382 1 Additive 1 Totalizer Position Read/Write uint 0 65535

383 1 Additive 1 Totalizer Line Read/Write uint 0 65535

384 1 Base Product 2 Totalizer Position Read/Write uint 0 65535

385 1 Base Product 2 Totalizer Line Read/Write uint 0 65535

386 1 Additive 2 Totalizer Position Read/Write uint 0 65535

387 1 Additive 2 Totalizer Line Read/Write uint 0 65535

388 1 Company Address Position 1 Read/Write uint 0 65535

389 1 Company Address Line 1 Read/Write uint 0 65535

390 1 Company Address Position 2 Read/Write uint 0 65535

391 1 Company Addres Line 2 Read/Write uint 0 65535

392 1 Company Address Position 3 Read/Write uint 0 65535

393 1 Company Address Line 3 Read/Write uint 0 65535

417 1 Modbus BOL Literal Index Read/Write uint 0 65535

418 1 BOL Line Read/Write uint 0 65535

Page 20: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

18

Register Length Description Read/Write Data Type Min Value Max Value

419 80 BOL Literals Read/Write uint 32 122

550 1 Prompt Length Read/Write uint 0 65535

551 1 BOL Line Read/Write uint 0 65535

552 1 BOL Position Read/Write uint 0 65535

553 20 Prompts Read/Write char 32 122

573 1 Prompt Length Read/Write uint 0 65535

574 1 BOL Line Read/Write uint 0 65535

575 1 BOL Position Read/Write uint 0 65535

576 20 Prompts Read/Write char 32 122

596 1 Prompt Length Read/Write uint 0 65535

597 1 BOL Line Read/Write uint 0 65535

598 1 BOL Position Read/Write uint 0 65535

599 20 Prompts Read/Write char 32 122

619 1 Prompt Length Read/Write uint 0 65535

620 1 BOL Line Read/Write uint 0 65535

621 1 BOL Position Read/Write uint 0 65535

622 20 Prompts Read/Write char 32 122

642 1 Prompt Length Read/Write uint 0 65535

643 1 BOL Line Read/Write uint 0 65535

644 1 BOL Position Read/Write uint 0 65535

645 20 Prompts Read/Write char 32 122

665 1 Prompt Length Read/Write uint 0 65535

666 1 BOL Line Read/Write uint 0 65535

667 1 BOL Position Read/Write uint 0 65535

668 20 Prompts Read/Write char 32 122

688 1 Prompt Length Read/Write uint 0 65535

689 1 BOL Line Read/Write uint 0 65535

690 1 BOL Position Read/Write uint 0 65535

691 20 Prompts Read/Write char 32 122

711 1 Prompt Length Read/Write uint 0 65535

712 1 BOL Line Read/Write uint 0 65535

713 1 BOL Position Read/Write uint 0 65535

714 20 Prompts Read/Write char 32 122

Hazard Registers

Register Length Description Read/Write Data Type Min Value Max Value

734 200 Hazard Definitions Read/Write char 32 122

Page 21: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

19

Product Registers

Note: Last Product Definition register used=2283 (only 6 additives).

Register Length Description Read/Write Data Type Min Value Max Value

2200 1 Modbus Product Definition Index Read/Write uint 0 65535

2201 1 Hazard Index Read/Write uint 0 65535

2202 6 Product Code Read/Write char 48 57

2208 25 Long Product Description Read/Write char 32 122

2233 10 Product Description Read/Write char 32 122

2243 1 Product Index Component 1 Read/Write uint 0 65535

2244 1 Recipe Percentage Read/Write uint 0 65535

2245 1 Product Index Component 2 Read/Write uint 0 65535

2246 1 Recipe Percentage Read/Write uint 0 65535

2247 1 Product Index Component 3 Read/Write uint 0 65535

2248 1 Recipe Percentage Read/Write uint 0 65535

2249 1 Product Index Component 4 Read/Write uint 0 65535

2250 1 Recipe Percentage Read/Write uint 0 65535

2251 1 Product Index Component 5 Read/Write uint 0 65535

2252 1 Recipe Percentage Read/Write uint 0 65535

2253 1 Product Index Component 6 Read/Write uint 0 65535

2254 1 Recipe Percentage Read/Write uint 0 65535

2255 1 Product Index Component 7 Read/Write uint 0 65535

2256 1 Recipe Percentage Read/Write uint 0 65535

2257 1 Product Index Component 8 Read/Write uint 0 65535

2258 1 Recipe Percentage Read/Write uint 0 65535

2259 1 Additive 1 Code Read/Write uint 0 65535

2260 1 Additive Percentage Read/Write uint 0 65535

2261 1 Additive 2 Code Read/Write uint 0 65535

2262 1 Additive Percentage Read/Write uint 0 65535

2263 1 Additive 3 Code Read/Write uint 0 65535

2264 1 Additive Percentage Read/Write uint 0 65535

2265 1 Additive 4 Code Read/Write uint 0 65535

2266 1 Additive Percentage Read/Write uint 0 65535

2267 1 Additive 5 Code Read/Write uint 0 65535

2268 1 Additive Percentage Read/Write uint 0 65535

2269 1 Additive 6 Code Read/Write uint 0 65535

2270 1 Additive Percentage Read/Write uint 0 65535

2271 1 Additive Null Read/Write uint 0 65535

2272 1 Sampler 1 Code Read/Write uint 0 65535

2273 1 Sampler Pacing Rate Read/Write uint 0 65535

2274 1 Sampler 2 Code Read/Write uint 0 65535

2275 1 Sampler Pacing Rate Read/Write uint 0 65535

Page 22: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

20

Register Length Description Read/Write Data Type Min Value Max Value

2276 1 Sampler 3 Code Read/Write uint 0 65535

2277 1 Sampler Pacing Rate Read/Write uint 0 65535

2278 1 Sampler 4 Code Read/Write uint 0 65535

2279 1 Sampler Pacing Rate Read/Write uint 0 65535

2280 1 Sampler 5 Code Read/Write uint 0 65535

2281 1 Sampler Pacing Rate Read/Write uint 0 65535

2282 1 Sampler 6 Code Read/Write uint 0 65535

2283 1 Sampler Pacing Rate Read/Write uint 0 65535

2284 1 Sampler Null Read/Write uint 0 65535

Driver Database Registers

Register Length Description Read/Write Data Type Min Value Max Value

2300 1 Modbus Card Database Index Read/Write uint 0 65535

2301 2 Card Number Read/Write char 48 57

2303 1 PIN ID For Card Read/Write char 48 57

2304 1 Company ID Read/Write char 48 57

2305 1 Language Index For Driver Read/Write uint 0 65535

2306 1 Bit Mapped Preset Lockout Read/Write uint 0 65535

2700 25 Authorized Driver Read/Write char 32 122

2725 25 Stockholder Read/Write char 32 122

2750 25 Customer Read/Write char 32 122

2775 25 Account Read/Write char 32 122

2800 25 Consignee Read/Write char 32 122

2825 25 Driver Name Read/Write char 32 122

2850 1 Input Terminating Key Read/Write char 32 122

2851 24 Input Data Read/Write char 32 122

2900 80 Card Data Read/Write char 32 122

GPS Site Database Definitions

Register Length Description Read/Write Data Type Min Value Max Value

2350 1 Modbus GPS Site Database Index Read/Write uint 0 65535

2351 15 GPS Site Name Read/Write char 32 122

2366 2 GPS Site Latitude Read/Write char 32 122

2368 2 GPS Site Longitude Read/Write char 32 122

Page 23: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

21

Bilingual Message Support

Register Length Description Read/Write Data Type Min Value Max Value

2369 1 Language Index For Driver Read/Write uint 0 65535

2400 1 Modbus Language Prompt Index Read/Write uint 0 65535

2401 1 Language Prompt Code Read/Write char 32 122

2402 60 Language Message Read/Write char 32 122

Log Message Registers

Register Length Description Read/Write Data Type Min Value Max Value

2600 2 Host Log Message Count Read/Write uint 0 65535

2602 2 Event Log YYMMDD Read/Write uint 0 65535

2604 2 Event Log HHMMSS Read/Write uint 0 65535

2606 20 Event Log Message for RCU Read/Write uint 0 65535

2686 1 Host Log Extract Message Index Read/Write uint 0 65535

Transaction Registers

The transaction registers are unique because the data you get back is configured by writing to register 7800 and 7801. Reading a single transaction is typically a three-step process:

1. Write the BOL number to register 7800 to configure which transaction the data relates to. 2. Write a 0 to register 7801 and then read the header information (start/stop time, card number, number

of details, etc.). 3. Write a 1 to register 7801 and then loop through all the details of the transaction (the number of details

should have been retrieved in step two).

3.10.1 Transaction Register Configuration

Register Length Description Read/Write Data Type Min

Value Max Value

7800 1

Modbus Transaction Number Index Read/Write uint 1 9999

7801 1

Modbus Trasaction Detail Index Read/Write uint 0 999

3.10.2 Transaction Header Registers

Register Length Description Read/Write Data Type Min

Value Max Value

7810 2

Transaction Header Card Number Read uint 0 99999999

7812 1 Transaction Header Company Read uint 0 65535

Page 24: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

22

Register Length Description Read/Write Data Type Min

Value Max Value

7813 1

Transaction Header Load Start Read uint 0 2459

7814 1

Transaction Header Load Stop Read uint 0 2459

7815 1

Transaction Head Load Stop(or Start) Date Read uint 0 1231

7816 1

Transaction Header Number of Detail Records Read uint 1 9999

7817 25 Transaction Header Prompts Read char 32 122

7842 25 Transaction Header Prompts Read char 32 122

7867 25 Transaction Header Prompts Read char 32 122

7892 25 Transaction Header Prompts Read char 32 122

3.10.3 Transaction Detail Registers

Register Length Description Read/Write Data Type Min

Value Max Value

7810 1 Transaction Detail Preset Read uint 0 65535

7811 1 Transaction Detail Type Read uint 0 65535

7812 6

Transaction Detail Product Code Read char 32 122

7818 2

Transaction Detail GOV Delivered Read uint 0 4294967295

7820 2

Transaction Detail GSV Delivered Read uint 0 4294967295

7822 1

Transaction Detail Average Temperature Read int -32768 32767

7823 1

Transaction Detail Density Gravity Read uint 0 9999

7824 1

Transaction Detail Compartment ID Read uint 0 65535

7825 1 Transaction Detail Pressure Read int -32768 32767

7826 1

Transaction Detail API Expansion Coefficient Read uint 0 65535

7827 1

Transaction Detail Corrected Density Gravity Read uint 0 65535

7828 1

Transaction Detail Volume Correction Factor Read uint 0 65535

7829 1 Transaction Detail BSW Read uint 0 65535

7830 1

Transaction Detail Alibilog Alarm Read uint 0 65535

7831 2

Transaction Detail Batch Number Read uint 0 4294967295

Page 25: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

23

Register Length Description Read/Write Data Type Min

Value Max Value

7833 2

Transaction Detail Mass Delivered Read uint 0 4294967295

7835 1

Transaction Detail Termperature Correction Factor Read uint 0 65535

7836 1

Transaction Detail Pressure Correction Factor Read uint 0 65535

Custom Logic Registers

Register Length Description Read/Write Data Type Min Value Max Value

12000 2 Custom Logic Register [0000] Read/Write uint 0 65535

… … … … … … …

13023 2 Custom Logic Register [1023] Read/Write uint 0 65535

Page 26: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

24

Chapter 4 Configuration Registers

This section outlines the first 100 configuration registers for the RCU and equipment levels available in the MultiLoad, additional configuration registers are accessable through the extended service registers using Smith protocol. The minimum, maxiumum and default values are specifc to the configuration parameter and not the register size.

Configuration Data Types

Configuration data types listed below have more than one option selectable within the configuration.

Multiple Levels:

Disable/Enable

Definition Numerical Value

Disabled 0

Enabled 1

W&M Alarm Reset Mode

Definition Numerical Value

Authorize 0

Clear 1

2 minutes 2

5 minutes 3

15 minutes 4

30 minutes 5

60 minutes 6

3 hours 7

12 hours 8

24 hours 9

Chapter

4

Page 27: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

25

Deliver Type

Output Pulse Type

Definition Numerical Value

Gross 0

Net 1

Mass 2

RCU Level:

Program Mode Language

Driver Language

Definition Numerical Value

English 0

Spanish 1

Portuguese 2

French 3

German 4

Simplified Chinese 5

Traditional Chinese 6

Thai 7

Card Reader Type

Definition Numerical Value

Disabled 0

Bucket Captive 1

Bucket Noncaptive 2

Slot Captive 3

Slot Noncaptive 4

iButton 5

Bucket Dual Noncaptive 6

Slot Dual Noncaptive 7

Page 28: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

26

Processing Mode

Definition Numerical Value

Stand-alone 0

Remote 1

UAP 2

UAP Gate 3

Mass Measure Used

Definition Numerical Value

None 0

Pounds 1

Short Tons 2

Long Tons 3

Grams 4

Kilograms 5

Density of Air 6

Metric Tons 7

Measure Used

Definition Numerical Value

Gallons 0

Liters 1

Cubic Meters 2

Tonnes 3

Kilograms 4

Grams 5

Pounds 6

Barrels 7

No Measure 8

Liters 9

Page 29: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

27

Decaliters 10

Display Load Volume

Definition Numerical Value

Disabled 0

Gross 1

Net 2

Mass 3

Decimal Mark Type

Definition Numerical Value

Decimal 0

Comma 1

SCS Prompting

Definition Numerical Value

None 0

BSW 1

Density 2

BSW and Density 3

Sampler UOM

Definition Numerical Value

None 0

cc 1

oz 2

Page 30: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

28

Bay Level:

Temperature UOM

Definition Numerical Value

Celsius 0

Fahrenheit 1

Deadman Mode

Definition Numerical Value

No Mode 0

Continuous Hold 1

Hold & Release 2

Push 3

Preset Level:

Blending Type

Definition Numerical Value

None 0

Ratio 1

Sequential 2

Ratio and Sequential 3

Watercut 4

Blend On Lead Comp

Definition Numerical Value

None 0

First Component 1

Highest Percentage 2

Lowest Percentage 3

Page 31: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

29

Flow Rate Mode

Definition Numerical Value

Minutes 0

Hours 1

Meter Level:

Meter Type

Definition Numerical Value

Volume Pulse 0

Mass Pulse 1

Volume Analog 2

Khrone 3

Micromotion 4

Component Level:

API 54YG Products

Definition Numerical Value

No Product 0

Propane 1

Propylene 2

Butane 3

Isobutane 4

Isobutene 5

Cis-But-2-ene 6

Trans-But-2-ene 7

But-1-ene 8

But-1,3-dien 9

Methanol 10

Ethanol 11

Page 32: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

30

API 54YG Products

Definition Numerical Value

Isopropanol 12

Isobutanol 13

MTBE 14

TAME 15

Benzol 16

Toluol 17

o-Xylol 18

m-Xylol 19

p-Xylol 20

API BIO

Definition Numerical Value

None 0

E5 1

E10 2

E80 3

E85 4

E100 5

Benzin/Petrol 6

Diesel 7

B5 Rapeseed Oil 8

B7 Rapeseed Oil 9

B100 Rapeseed Oil 10

B5 Soy Bean Oil 11

B7 Soy Bean Oil 12

B100 Soy Bean Oil 13

Page 33: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

31

Density UOM

Definition Numerical Value

kg/m3 1

Api Gravity 2

Relative Density 3

Pressure UOM

Definition Numerical Value

psig 1

kPa 2

bar 3

API ASTMD1555 Product

Definition Numerical Value

None 0

Benzene 1

Cumene 2

Cyclohexane 3

Ethylbenzene 4

Styrene 5

Toluene 6

m-Xylene 7

o-Xylene 8

p-Xylene 9

300-350°F Hydrocarbon 10

350-400°F Hydrocarbon 11

Additive Level:

Page 34: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

32

Additive Type

Definition Numerical Value

Solenoid w/ Meter 1

Piston w/ Normal Feedback 2

Piston w/ Inverted Feedback 3

Piston w/ No Feedback 4

Analog Valve w/ Meter 5

Additive Mode

Definition Numerical Value

Start On Batch 0

Start On High Flow 1

Start On Volume 2

Tank Level:

Active Tank Mode

Definition Numerical Value

Deactive 0

Loading 1

Unloading 2

Loading and Unloading 3

Security Level:

Password Complexity

Definition Numerical Value

None 0

Alpha 1

Numeric 2

Alpha and Numeric 3

Special Character 4

Page 35: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

33

Password Complexity

Definition Numerical Value

Alpha and Special Character 5

Numeric and Special Character 6

Alpha, Numeric, and Special Character 7

FCM Addressing:

MSB FCM Address Bitwise Representation LSB

Custom Logic

1 bit

Enabled

1 bit

Invert

1 bit

FCM Number

5 bits

Port Number

6 bits

Examples

FCM Number

Port Number

Bitwise Representation Numerical Value

1 4 0 1 0 00001 000100 4164

3 11 0 1 0 00011 001011 4299

Configuration Indexing

Configuration Index determines the preset, component, meter and additive you are editing when writing commands to the modbus registers addressed in this chapter.

Register Length Description Read/Write Data Type Min Value Max Value

996 1 Modbus Preset Index Read/Write unsigned int 0 11

997 1 Modbus Component Index Read/Write unsigned int 0 7

998 1 Modbus Meter Index Read/Write unsigned int 0 4

999 1 Modbus Additive Index Read/Write unsigned int 0 15

Page 36: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

34

RCU Level Configuration Registers

Register Length Description Read/Writ

e Data Type Min

Value Max

Value Default Value

1008 2 Reload ROM Lang File

Read/Write disable/enable Read/Writ

e

1016 2 Driver Language Read/Write language English

1018 2 Program Mode Language

Read/Write language English

1020 2 Card Reader Type Read/Write card-reader 1

1022 2 Prox Card Pull Secs Read/Write unsigned int 2 30 3

1024 2 Processing Mode Read/Write remote

processing Enabled

1026 2 Message Swap Delay Read/Write unsigned int 1 60 3

1028 2 Message Hold Delay Read/Write unsigned int 1 60 10

1030 2 Max GPS Site Distance

Read/Write unsigned int 0 10000 200

1032 2 Auto Authorize Read/Write disable/enable Disabled

1034 2 MM/DD/YY Date Read/Write disable/enable Enabled

1036 2 Mass Measure Used Read/Write mass measure None

1038 2 Load Date From End Read/Write disable/enable Enabled

1040 2 Measure Used Read/Write measures Gallons

1042 2 Print Blend Details Read/Write unsigned int 0 2 1

1044 2 Compartment Entry Read/Write disable/enable Disabled

1046 2 Config Timeout Mins Read/Write unsigned int 0 99 20

1048 2 Print Totalizers Read/Write totalizers None

1050 2 Simulation Mode Read/Write disable/enable Disabled

1052 2 Large Prompts Read/Write disable/enable Disabled

1054 2 Confirm Flow Starts Read/Write disable/enable Disabled

1056 2 Display Adtv as CCs Read/Write disable/enable Disabled

1058 2 Display Hundredths Read/Write disable/enable Disabled

1060 2 Use Hundredths Read/Write disable/enable Disabled

1062 2 W&M Density Lock Read/Write disable/enable Disabled

1064 2 Print Ticket Read/Write disable/enable Disabled

1066 2 Form Feed After Ticket

Read/Write disable/enable Enabled

1068 2 Print Ticket on PCM Read/Write disable/enable Disabled

1070 2 Ticket PCM Read/Write unsigned int 0 32 0

1072 2 Meter Arch Timeout Read/Write unsigned int 0 120 120

1074 2 Inactivity Timeout Read/Write unsigned int 0 60 35

1076 2 Print Msg Log on PCM

Read/Write disable/enable Disabled

1078 2 Message Log PCM# Read/Write unsigned int 0 32 0

Page 37: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

35

Register Length Description Read/Writ

e Data Type Min

Value Max

Value Default Value

1080 2 No Prox Pull If Flow Read/Write disable/enable Disabled

1082 2 Host Down Timeout Read/Write unsigned int 30 999 120

1084 2 Host Wait Timeout Read/Write unsigned int 60 999 999

1086 2 Prt Alibi Log on PCM Read/Write disable/enable Disabled

1088 2 Alibi Log PCM# Read/Write unsigned int 0 3 0

1090 2 Swing Arm Secondary Read/Write disable/enable Disabled

1092 2 Screen Saver Timeout

Read/Write unsigned int 0 65535 600

1094 2 Screen Saver Bright Read/Write percent 0 10000 5000

1096 2 Min Time Change Secs

Read/Write unsigned int 0 65535 60

1098 2 Display Load Volume Read/Write disable/enable Disabled

1100 2 Display Help Read/Write disable/enable Disabled

1102 2 Measure On Load Scrn

Read/Write disable/enable Disabled

1104 2 Status Scrn Lockout Read/Write disable/enable Enabled

1106 2 Load Screen Timeout Read/Write unsigned int 0 65535 60

1108 2 Preset Slct Timeout Read/Write unsigned int 0 65535 0

1110 2 Pixel Test Read/Write disable/enable Disabled

1112 2 Meter Proving Mode Read/Write disable/enable Disabled

1114 2 Decimal Mark Type Read/Write Decimal Mark Decimal

1116 2 Display Preset Tot. Read/Write disable/enable Disabled

1118 2 Default Driver Number

Read/Write unsigned int 1 99999

99 1

1120 2 Default Facility Code Read/Write unsigned int 0 99999

99 0

1122 2 SCS Prompting (SCS Only)

Read/Write scs prompt None All None

1124 2 Sample UOM Read/Write Sample UOM

units None oz None

1126 2 Unused Read/Write

1128 2 SCS Prompting Display (SCS Only)

Read/Write SCS Display After Befor

e After

1130 2 Max Lines on Ticket Read/Write unsigned int 0 106 66

1132 2 Startup Keypad Locked

Read/Write disable/enable

Disabled

1134 2 Screen Brightness Read/Write Percent 500 10000

10000

1136 2 W&M Key FCM# Read/Write fcm address Disabled

1138 2 Program Key FCM# Read/Write fcm address Disabled

1180 2 RCU Address Read/Write unsigned int 0 999 1

Page 38: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

36

Bay Level Configuration Registers

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1200 2 Number Bay Presets Read/Write unsigned int 1 12 1

1202 2 Number of FCMs Read/Write unsigned int 0 32 1

1204 2 Number of PCMs Read/Write unsigned int 0 32 1

1206 2 Temperature UOM Read/Write Temperature

UOM C

1208 2 Canada API Limits Read/Write disable/enable Disable

d

1210 2 Number of Tanks Read/Write unsigned int 0 10 0

1212 2 Bay Number Read/Write unsigned int 0 9999 0

1214 2 Number External Presets

Read/Write unsigned int 0 12 0

1216 2 Unused Read/Write

1218 2 Unused Read/Write

1356 2 Output Pulse Type Read/Write Delivery Type Gross

1358 2 Start Transaction Read/Write fcm address Disable

d

1360 2 End Transaction Read/Write fcm address Disable

d

1362 2 Output Pulse FCM# Read/Write fcm address Disable

d

1364 2 Output Pulse Factor Read/Write unsigned div

1000 0.001 50 10

1366 2 Deadman Mode Read/Write Unsigned int 0 3 0

1368 2 Input Deadman FCM#

Read/Write fcm address Disable

d

1370 2 Deadman Stop Timer Read/Write Unsigned int 0 65535 180

1372 2 Output Deadman FCM#

Read/Write fcm address Disable

d

1374 2 Deadman Warning Timer

Read/Write Unsigned int 0 65535 30

1376 2 Deadman Bypass FCM#

Read/Write fcm address Disable

d

1378 2 Alarm Out FCM# Read/Write fcm address Disable

d

1380 2 Authorized FCM# Read/Write fcm address Disable

d

1382 2 Permiss 0 FCM# Read/Write fcm address Disable

d

Page 39: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

37

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1384 2 Permiss 1 FCM# Read/Write fcm address Disable

d

1386 2 Permiss 2 FCM# Read/Write fcm address Disable

d

1388 2 Permiss 3 FCM# Read/Write fcm address Disable

d

1390 2 Permiss 4 FCM# Read/Write fcm address Disable

d

1392 2 Permiss 5 FCM# Read/Write fcm address Disable

d

1394 2 Permiss 6 FCM# Read/Write fcm address Disable

d

1396 2 Permiss 7 FCM# Read/Write fcm address Disable

d

1398 2 Permiss Out FCM# Read/Write fcm address Disable

d

Preset Configuration Registers

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1600 2 Flow Control Module#

Read/Write unsigned int 0 31 0

1602 2 Side-Stream on Mtr# Read/Write unsigned int 0 6 0

1604 2 Side Stream on Any Meter

Read/Write disable/enable Disabled

1606 2 Unused Read/Write

1608 2 Meter Address Read/Write unsigned int 0 255 0

1610 2 Meter Type Read/Write meter type Volume

Pulse

1612 2 Max Quad Errors Read/Write unsigned int 0 65535 10

1614 2 Reset Quad Errors Read/Write unsigned int 1000 65535 10000

1616 2 Low Flow Alarm Rate Read/Write unsigned int 0 65535 10

1618 2 Low Flow Alarm Time

Read/Write unsigned div1000

0 999.99

9 10

1620 2 Excess Flw Alrm Rate Read/Write unsigned int 0 9999 800

1622 2 Minimum Flow Rate Read/Write unsigned int 0 9999 50

1624 2 Maximum Flow Rate Read/Write unsigned int 0 9999 650

1626 2 Low Flow DB Rate Read/Write unsigned int 0 9999 40

1628 2 High Flow DB Rate Read/Write unsigned int 0 9999 40

1630 2 1st Stage DB Rate Read/Write unsigned int 0 9999 40

1632 2 2nd Stage DB Rate Read/Write unsigned int 0 9999 40

Page 40: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

38

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1634 2 Valve Cntl Alrm Time Read/Write unsigned div1000

0 65.535 10

1636 2 Valve Fault Alrm Vol Read/Write unsigned int 0 65535 30

1638 2 Creep Reset Time Read/Write unsigned int 0 65535 0

1640 2 Ratio Adj P. Factor Read/Write unsigned

div100 0 655.35 10

1642 2 Ratio Adj D. Factor Read/Write unsigned

div100 0 655.35 0.3

1644 2 Meter Creep Alrm Vol

Read/Write unsigned int 0 65535 15

1646 2 Flow Scan Time Read/Write unsigned div1000

0.1 1 0.1

1648 2 Valve Dwell Time Read/Write unsigned div1000

0.01 65.535 1

1650 2 Valve Dwell StepRate

Read/Write unsigned int 0 9999 0

1652 2 Valve Dwell StepTime

Read/Write unsigned div1000

0 5 0

1654 2 Adaptive Valve Control

Read/Write disable/enable Disabled

1656 2 Analog Valve Control Read/Write disable/enable Disabled

1658 2 4-20mA Increase Step

Read/Write unsigned div

1000 0 4 0.08

1660 2 4-20mA Decrease Step

Read/Write unsigned div

1000 0 4 0.8

1662 2 Excess Flow Alarm Time

Read/Write unsigned div

1000 0 65535 0

1664 2 Analog Valve No Flow mA

Read/Write unsigned div

1000 0 20.000 0

1666 2 Unused Read/Write

1668 2 Analog Meter Flow Rate @ 4mA

Read/Write unsigned int 0 9999 0

1670 2 Analog Meter Flow Rate @ 20mA

Read/Write unsigned int 0 9999 600

1672 2 Analog Meter Flow Rate Offset

Read/Write signed div1000 -

9.999 9.999 0

1674 2 Analog Meter Flow Rate Cutoff

Read/Write unsigned int 0 9999 0

1676 2 Unused Read/Write

1678 2 Unused Read/Write

1680 2 Density Sensor FCM#

Read/Write fcm address analog input

Disabled

1682 2 Unused Read/Write

Page 41: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

39

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1684 2 Default Density Read/Write unsigned div10 0 9999.9 0

1686 2 Alarm Low Density Read/Write unsigned div10 0 9999.9 0

1688 2 Alarm High Density Read/Write unsigned div10 0 9999.9 12000

1690 2 Density Alarm Time Read/Write unsigned int 0 60 0

1692 2 Density @ Low Value

Read/Write unsigned div10 0 4000 0

1694 2 Density @ High value

Read/Write unsigned div10 0 4000 12000

1696 2 Density Offset Read/Write signed div10 -300 300 0

1698 2 Unused Read/Write

1700 2 Unused Read/Write

1702 2 Pressure Sensor FCM#

Read/Write fcm address analog input

Disabled

1704 2 Unused Read/Write

1706 2 Default Pressure Read/Write unsigned

div100 0

9999.99

9999.99

1708 2 Alarm Low Pressure Read/Write unsigned

div100 0

9999.99

100

1710 2 Alarm High Pressure Read/Write unsigned

div100 0

9999.99

450

1712 2 Pressure Alarm Time Read/Write unsigned int 0 60 0

1714 2 Pressure @ Low Value

Read/Write unsigned

div100 0 4000 0

1716 2 Pressure @ High Value

Read/Write unsigned

div100 0 4000 650

1718 2 Pressure Offset Read/Write signed div100 -30 30 0

1678 2 Unused Read/Write

1680 2 Relative Density Sensor FCM#

Read/Write fcm address analog input

Disabled

1682 2 Unused Read/Write

1684 2 Default Relative Density

Read/Write unsigned div10000

0 2 0

1686 2 Alarm Low Relative Density

Read/Write unsigned div10000

0 2 0

1688 2 Alarm High Relative Density

Read/Write unsigned div10000

0 2 1.2

1690 2 Rel. Den. Alrm Time Read/Write unsigned int 0 60 0

1692 2 Relative Density @ Low Value

Read/Write unsigned div10000

0 4 0

1694 2 Relative Density @ High Value

Read/Write unsigned div10000

0 4 1.2

Page 42: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

40

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1696 2 Relative Density Offset

Read/Write signed

div10000 -0.3 0.3 0

1740 2 2% MF Limit Ref Read/Write unsigned div10000

0 6.5535 0

1742 2 Adjacent MF Dev Limt

Read/Write unsigned div10000

0 0.1 0

1744 2 Temp Offset Limit Read/Write unsigned

div100 0 5 3

1746 2 Output Pulse FCM# Read/Write fcm address Disabled

1748 2 Output Pulse Factor Read/Write unsigned div

1000 1.000 50.000 10.000

1760 2 Unused Read/Write

1762 2 Alarm Out FCM# Read/Write fcm address Disabled

1764 2 Authorized FCM# Read/Write fcm address Disabled

1766 2 Permiss FCM# Read/Write fcm address Disabled

1768 2 Permiss Out FCM# Read/Write fcm address Disabled

1770 2 Meter K-Factor Read/Write unsigned int 1 65535 50

1772 2 Quad Check Enable Read/Write disable/enable Disabled

1774 2 Unused Read/Write

1776 2 Temperature Offset Read/Write signed div100 -5 5 0

1778 2 Temperature Alarm Time

Read/Write unsigned int 0 60 0

1780 2 Temp Sensor FCM# Read/Write fcm address analog input

Disabled

1782 2 Temperature Sensor Read/Write disable/enable Enabled

1784 2 Default Temperature Read/Write signed div10 -999.9 999.9 999.9

1786 2 Alarm Low Temp Read/Write signed div10 -999.9 999.9 -999.9

1788 2 Alarm High Temp Read/Write signed div10 -999.9 999.9 999.9

1790 2 Temp Module Type Read/Write unsigned int 0 19 0

1792 2 Temperature @ Low Value

Read/Write signed div10 -999.9 999.9 -50

1794 2 Temperature @ High Value

Read/Write signed div10 -999.9 999.9 350.0

1796 2 Unused Read/Write

1798 2 unused Read/Write

1800 2 Unused Read/Write

1802 2 Unused Read/Write

1804 2 Unused Read/Write

1806 2 Unused Read/Write

1808 2 Unused Read/Write

1810 2 Unused Read/Write

Page 43: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

41

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1812 2 Unused Read/Write

1814 2 Unused Read/Write

1816 2 API Gravity Sensor FCM#

Read/Write fcm address analog input

Disabled

1818 2 Default API Gravity Read/Write unsigned div10 -1000 11000 0

1820 2 Alarm Low API Gravity

Read/Write unsigned div10 -1000 11000 0

1822 2 Alarm High API Gravity

Read/Write unsigned div10 -1000 11000 11000

1824 2 API Gravity Alarm Time

Read/Write unsigned int 0 60 0

1826 2 API Gravity @ Low Value

Read/Write unsigned div10 -1000 11000 0

1828 2 API Gravity @ High Value

Read/Write unsigned div10 -1000 11000 11000

1830 2 API Gravity Offset Read/Write unsigned div10 -3000 3000 0

Component Configuration Registers

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1800 2 Meter# Read/Write unsigned int 1 6 1

1802 2 High Flow Rate Read/Write unsigned int 0 9999 600

1804 2 1st Stage Trip Vol Read/Write unsigned int 0 65535 70

1806 2 1st Stage Flow Rate Read/Write unsigned int 0 9999 225

1808 2 2nd Stage Trip Vol Read/Write unsigned int 0 65535 20

1810 2 2nd Stage Flow Rate Read/Write unsigned int 0 9999 150

1812 2 Final Trip Vol Read/Write unsigned

div100 0 655.35 1.15

1814 2 Final Trip Max Time Read/Write unsigned div1000

0 65.535 5

1816 2 Final Trip Vol Lock Read/Write disable/enable Disabled

1818 2 Unauth Flow Alrm Vol

Read/Write unsigned int 0 65535 10

1820 2 Tank Group Read/Write unsigned int 0 99999

99 0

1822 2 W&M Recipe Percentage

Read/Write unsigned div

100 0.00 100.00 0.00

1824 2 Unused Read/Write

1826 2 BlkValve Open Rate Read/Write unsigned int 0 9999 0

1828 2 BlkValve Open Delay Read/Write unsigned int 0 65535 0

1830 2 B.V. Open Alrm Time Read/Write unsigned int 2 65535 10

Page 44: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

42

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1832 2 B.V. Close Alrm Time Read/Write unsigned int 2 65535 10

1834 2 Pump Start Delay Read/Write unsigned int 0 65535 3

1836 2 Pump Stop Delay Read/Write unsigned int 0 65535 30

1838 2 Pump Start Alrm Time

Read/Write unsigned int 2 65535 2

1840 2 Flow Start Delay Read/Write unsigned int 0 65535 5

1842 2 Unused Read/Write

1844 2 Unauth Reset Time Read/Write unsigned int 0 65535 0

1846 2 Unused Read/Write

1848 2 Fallback Rate Read/Write unsigned int 0 9999 350

1850 2 Fallback Time Read/Write unsigned int 0 65535 0

1852 2 Fallback Retry Time Read/Write unsigned int 0 65535 0

1854 2 Fallback Retry Vol Read/Write unsigned int 0 65535 0

1856 2 Fallback Minimum Pressure

Read/Write unsigned

div100 0

999999

0

1858 2 Fallback Minimum Rate

Read/Write unsigned int 0 9999 0

1860 2 Fallback Increase Rate

Read/Write unsigned int 0 9999 0

1862 2 Fallback Decrease Rate

Read/Write unsigned int 0 9999 0

1864 2 Fallback Retry Min Pressure

Read/Write unsigned

div100 0

999999

0

1866 2 Fallback Vapor Pressure

Read/Write disable/enable Disabled

1868 2 Unused Read/Write

1870 2 Unused Read/Write

1872 2 Unused Read/Write

1874 2 Unused Read/Write

1876 2 Unused Read/Write

1878 2 API Table Read/Write API table name None

1880 2 API 54YG Product Read/Write 54YG Products 0 20 None

1882 2 API Extrapolated Range

Read/Write disable/enabl

e Disabled

1884 2 API BIO Read/Write PTB BIO Products

0 13 None

1886 2 API Gravity Read/Write signed div10 -100 1100 0

1888 2 Relative Density Read/Write unsigned div10000

0 9 0

1890 2 Default Density Read/Write unsigned div10 0 9999.9 0

1892 2 Expansion Coef. Read/Write unsigned div10 0 2000 0

1894 2 Hydrometer Used Read/Write disable/enable Disabled

Page 45: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

43

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1896 2 Commodity Type Read/Write commodity

type 0 3 1

1898 2 Expansion Coef. UOM

Read/Write expansion coef

uom type 1 2 1

1900 2 Density UOM Read/Write density uom

type 1 3 1

1902 2 Pressure UOM Read/Write pressure uom

type 1 3 3

1904 2 Reference Temperature

Read/Write unsigned int 0 9999 60

1906 2 Alcohol Percentage Read/Write Percent 0 100 0

1908 2 API Alarm Time Read/Write unsigned int 0 120 0

1910 2 Compressibility Factor

Read/Write unsigned int 0 99999 0

1912 2 API ASTMD1555 Product

Read/Write API ASTM

D1555

No Product

1914 2 Unused Read/Write

1916 2 Unused Read/Write

1918 2 Unused Read/Write

1920 2 Unused Read/Write

1922 2 Unused Read/Write

1924 2 Unused Read/Write

1926 2 Unused Read/Write

1928 2 Unused Read/Write

1930 2 Unused Read/Write

1932 2 Unused Read/Write

1934 2 Unused Read/Write

1936 2 Unused Read/Write

1938 2 Unused Read/Write

1940 2 Unused Read/Write

1942 2 Output Pulse FCM# Read/Write fcm address Disabled

1944 2 Output Pulse Factor Read/Write unsigned div

1000 1 50 10

1946 2 Output Pulse Type Read/Write Delivery Type Gross

1948 2 Close Blk Val FCM# Read/Write fcm address Disabled

1950 2 Blk Val Status FCM Read/Write fcm address Disabled

1952 2 Open Blk Val FCM# Read/Write fcm address Disabled

1954 2 Unused Read/Write

1956 2 Pump Run FCM# Read/Write fcm address Disabled

1958 2 Pump Kill FCM# Read/Write fcm address Disabled

1960 2 Pump Status FCM# Read/Write fcm address Disabled

Page 46: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

44

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

1962 2 Alarm Out FCM# Read/Write fcm address Disabled

1964 2 Authorized FCM# Read/Write fcm address Disabled

1966 2 Permiss FCM# Read/Write fcm address Disabled

1968 2 Permiss Out FCM# Read/Write fcm address Disabled

1970 2 Meter Factor #1 Read/Write unsigned div10000

0.8 1.2 1

1972 2 Meter Factor #1 Rate

Read/Write unsigned int 0 9999 150

1974 2 Meter Factor #2 Read/Write unsigned div10000

0.8 1.2 1

1976 2 Meter Factor #2 Rate

Read/Write unsigned int 0 9999 200

1978 2 Meter Factor #3 Read/Write unsigned div10000

0.8 1.2 1

1980 2 Meter Factor #3 Rate

Read/Write unsigned int 0 9999 400

1982 2 Meter Factor #4 Read/Write unsigned div10000

0.8 1.2 1

1984 2 Meter Factor #4 Rate

Read/Write unsigned int 0 9999 800

1986 2 # Meter Factors Used

Read/Write unsigned int 1 4 4

1988 2 Unused Read/Write

Additive Configuration Registers

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

2000 2 Additive Enable Read/Write disable/enable Enabled

2002 2 Flow Control Module# Read/Write unsigned int 0 31 0

2004 2 FCM Port# Read/Write unsigned int 0 3 0

2006 2 W&M Controlled Read/Write disable/enable

Disabled

2008 2 Upstream Block Valve Read/Write disable/enabl

e Disabled

2010 2 Tank Group Read/Write unsigned int 0 99999

99 0

2012 2 Additive Type Read/Write disable/enable 0 4 0

2014 2 Additive P Factor Read/Write unsigned div10000

0.0000

10 0.1

2016 2 Additive I Time Read/Write unsigned div10000

0.0000

0.6000

0.3

2018 2 Additive D Time Read/Write uint div10000 0.000 0.600

0 0

Page 47: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

45

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

2020 2 Additive No Flow mA Read/Write unsigned div

1000 0.000

20.000

0.000

2022 2 Unused Read/Write

2032 2 Additive Mode Read/Write Additive Mode NONE

2034 2 Start Volume Read/Write unsigned int 0 65535 0

2036 2 Restart Volume Read/Write unsigned int 0 65535 0

2038 2 Solenoid Shut Pulses Read/Write unsigned int 0 255 0

2040 2 Shutoff Vol From End Read/Write unsigned int 0 65535 0

2042 2 LastInj Vol From End Read/Write unsigned int 0 65535 20

2044 2 Line Flush Min Vol Read/Write unsigned int 0 65535 0

2046 2 Assigned Component Read/Write unsigned int 0 8 0

2048 2 W&M Recipe Percentage

Read/Write percent div

10000 0.000

0% 6.553

5% 0.0000%

2050 2 Add Check Start VOL Read/Write unsigned int 0 65535 0

2052 2 Unused Read/Write

2054 2 Additive Vol/Inject Read/Write unsigned div10000

0 6.5535 0.02

2056 2 Vol/Inject Cal Factr Read/Write unsigned div10000

0.0001

6.5535 1

2058 2 Unused Read/Write

2060 2 Additive Tol Percentage

Read/Write Percent 0 100 0

2062 2 Additive Mtr K-Factr Read/Write unsigned int 0 65535 2600

2064 2 Additive Mtr Factor Read/Write unsigned div10000

0.0001

6.5535 1

2066 2 Max Pstn Missed Inj Read/Write unsigned int 0 65535 0

2068 2 MaxSolenoid Inj Time Read/Write unsigned div1000

0.1 10 4

2070 2 Under Add Alrm # Inj Read/Write unsigned int 0 65535 3

2072 2 Over Add Alrm # Inj Read/Write unsigned int 0 65535 3

2074 2 Check Add Tol Time Read/Write unsigned int 0 65535 10

2076 2 Unauth Flow Alrm Vol Read/Write unsigned int 0 65535 100

2078 2 Valve Fault Alrm Vol Read/Write unsigned int 0 65535 300

2080 2 Over Inject Vol Read/Write unsigned int 0 65535 0

2082 2 Creep Reset Time Read/Write unsigned int 0 65535 0

2084 2 Unauth Reset Time Read/Write unsigned int 0 65535 0

2086 2 Max Pistn Throw Time Read/Write unsigned div1000

0.1 10 1.8

2088 2 Pump Start Alrm Time Read/Write unsigned int 0 65535 2

2090 2 Meter Creep Alrm Vol Read/Write unsigned int 0 65535 150

2092 2 Remote Calibration Read/Write disable/enable Enabled

Page 48: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

46

Register Length Description Read/Write Data Type Min

Value Max

Value Default Value

2094 2 B.V. Open Alrm Time Read/Write unsigned int 0 65535 10

2096 2 B.V. Close Alrm Time Read/Write unsigned int 0 65535 10

2098 2 Pump Stop Delay Read/Write unsigned int 0 65535 3

2100 2 Flush Pump Run Time Read/Write unsigned int 0 65535 30

2102 2 Meter Flushed Read/Write disable/enable Disabled

2104 2 Solenoid Flushed Read/Write disable/enable Disabled

2106 2 Unused Read/Write

2108 2 W&M Alarm Promo Count

Read/Write unsigned int 0 65535 0

2110 2 W&M Alarm Reset

Mode Read/Write alarm count 0 10 0

2170 2 Unused Read/Write

2172 2 Unused Read/Write

2174 2 Unused Read/Write

2176 2 Flush Pump Run FCM#

Read/Write fcm address Disabled

2178 2 Close Blk Val FCM# Read/Write fcm address Disabled

2180 2 Blk Val Status FCM# Read/Write fcm address Disabled

2182 2 Open Blk Val FCM# Read/Write fcm address Disabled

2184 2 Test Button FCM# Read/Write fcm address Disabled

2186 2 Pump Run FCM# Read/Write fcm address Disabled

2188 2 Pump Kill FCM# Read/Write fcm address Disabled

2190 2 Pump Status FCM# Read/Write fcm address Disabled

2192 2 Alarm Out FCM# Read/Write fcm address Disabled

2194 2 Authorized FCM# Read/Write fcm address Disabled

2196 2 Permiss FCM# Read/Write fcm address Disabled

2198 2 Permiss Out FCM# Read/Write fcm address Disabled

Page 49: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

47

Chapter 5 Real -Time Registers

This chapter outlines two types of Real-Time registers. The Real-Time Totalizers are continuously updated, while the Real-Time value registers are update live and specific to the current batch.

Real-Time Totalizer Registers

5.1.1 Real-Time Preset Gross Totalizer

Register Length Preset Data Type Read/Write Min Value Max Value

3000 2 1 uint Read 0 1,000,000,000

3002 2 2 uint Read 0 1,000,000,000

3004 2 3 uint Read 0 1,000,000,000

3006 2 4 uint Read 0 1,000,000,000

3008 2 5 uint Read 0 1,000,000,000

3010 2 6 uint Read 0 1,000,000,000

3012 2 7 uint Read 0 1,000,000,000

3014 2 8 uint Read 0 1,000,000,000

3016 2 9 uint Read 0 1,000,000,000

3018 2 10 uint Read 0 1,000,000,000

3020 2 11 uint Read 0 1,000,000,000

3022 2 12 uint Read 0 1,000,000,000

5.1.2 Real-Time Meter Gross Totalizer

Register Length Preset Meter Data Type Read/Write Min Value Max Value

3024 2 1 1 uint Read 0 1,000,000,000

3026 2 1 2 uint Read 0 1,000,000,000

3028 2 1 3 uint Read 0 1,000,000,000

3030 2 1 4 uint Read 0 1,000,000,000

3032 2 1 5 uint Read 0 1,000,000,000

3034 2 2 1 uint Read 0 1,000,000,000

3036 2 2 2 uint Read 0 1,000,000,000

3038 2 2 3 uint Read 0 1,000,000,000

3040 2 2 4 uint Read 0 1,000,000,000

Chapter

5

Page 50: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

48

Register Length Preset Meter Data Type Read/Write Min Value Max Value

3042 2 2 5 uint Read 0 1,000,000,000

3044 2 3 1 uint Read 0 1,000,000,000

3046 2 3 2 uint Read 0 1,000,000,000

3048 2 3 3 uint Read 0 1,000,000,000

3050 2 3 4 uint Read 0 1,000,000,000

3052 2 3 5 uint Read 0 1,000,000,000

3054 2 4 1 uint Read 0 1,000,000,000

3056 2 4 2 uint Read 0 1,000,000,000

3058 2 4 3 uint Read 0 1,000,000,000

3060 2 4 4 uint Read 0 1,000,000,000

3062 2 4 5 uint Read 0 1,000,000,000

3064 2 5 1 uint Read 0 1,000,000,000

3066 2 5 2 uint Read 0 1,000,000,000

3068 2 5 3 uint Read 0 1,000,000,000

3070 2 5 4 uint Read 0 1,000,000,000

3072 2 5 5 uint Read 0 1,000,000,000

3074 2 6 1 uint Read 0 1,000,000,000

3076 2 6 2 uint Read 0 1,000,000,000

3078 2 6 3 uint Read 0 1,000,000,000

3080 2 6 4 uint Read 0 1,000,000,000

3082 2 6 5 uint Read 0 1,000,000,000

3084 2 7 1 uint Read 0 1,000,000,000

3086 2 7 2 uint Read 0 1,000,000,000

3088 2 7 3 uint Read 0 1,000,000,000

3090 2 7 4 uint Read 0 1,000,000,000

3092 2 7 5 uint Read 0 1,000,000,000

3094 2 8 1 uint Read 0 1,000,000,000

3096 2 8 2 uint Read 0 1,000,000,000

3098 2 8 3 uint Read 0 1,000,000,000

3100 2 8 4 uint Read 0 1,000,000,000

3102 2 8 5 uint Read 0 1,000,000,000

3104 2 9 1 uint Read 0 1,000,000,000

3106 2 9 2 uint Read 0 1,000,000,000

3108 2 9 3 uint Read 0 1,000,000,000

3110 2 9 4 uint Read 0 1,000,000,000

3112 2 9 5 uint Read 0 1,000,000,000

3114 2 10 1 uint Read 0 1,000,000,000

3116 2 10 2 uint Read 0 1,000,000,000

3118 2 10 3 uint Read 0 1,000,000,000

3120 2 10 4 uint Read 0 1,000,000,000

3122 2 10 5 uint Read 0 1,000,000,000

Page 51: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

49

Register Length Preset Meter Data Type Read/Write Min Value Max Value

3124 2 11 1 uint Read 0 1,000,000,000

3126 2 11 2 uint Read 0 1,000,000,000

3128 2 11 3 uint Read 0 1,000,000,000

3130 2 11 4 uint Read 0 1,000,000,000

3132 2 11 5 uint Read 0 1,000,000,000

3134 2 12 1 uint Read 0 1,000,000,000

3136 2 12 2 uint Read 0 1,000,000,000

3138 2 12 3 uint Read 0 1,000,000,000

3140 2 12 4 uint Read 0 1,000,000,000

3142 2 12 5 uint Read 0 1,000,000,000

5.1.3 Real-Time Component Gross Totalizer

Register Length Preset Component Data Type Read/Write Min Value Max Value

3144 2 1 1 uint Read 0 1,000,000,000

3146 2 1 2 uint Read 0 1,000,000,000

3148 2 1 3 uint Read 0 1,000,000,000

3150 2 1 4 uint Read 0 1,000,000,000

3152 2 1 5 uint Read 0 1,000,000,000

3154 2 1 6 uint Read 0 1,000,000,000

3156 2 1 7 uint Read 0 1,000,000,000

3158 2 1 8 uint Read 0 1,000,000,000

3160 2 2 1 uint Read 0 1,000,000,000

3162 2 2 2 uint Read 0 1,000,000,000

3164 2 2 3 uint Read 0 1,000,000,000

3166 2 2 4 uint Read 0 1,000,000,000

3168 2 2 5 uint Read 0 1,000,000,000

3170 2 2 6 uint Read 0 1,000,000,000

3172 2 2 7 uint Read 0 1,000,000,000

3174 2 2 8 uint Read 0 1,000,000,000

3176 2 3 1 uint Read 0 1,000,000,000

3178 2 3 2 uint Read 0 1,000,000,000

3180 2 3 3 uint Read 0 1,000,000,000

3182 2 3 4 uint Read 0 1,000,000,000

3184 2 3 5 uint Read 0 1,000,000,000

3186 2 3 6 uint Read 0 1,000,000,000

3188 2 3 7 uint Read 0 1,000,000,000

3190 2 3 8 uint Read 0 1,000,000,000

3192 2 4 1 uint Read 0 1,000,000,000

Page 52: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

50

Register Length Preset Component Data Type Read/Write Min Value Max Value

3194 2 4 2 uint Read 0 1,000,000,000

3196 2 4 3 uint Read 0 1,000,000,000

3198 2 4 4 uint Read 0 1,000,000,000

3200 2 4 5 uint Read 0 1,000,000,000

3202 2 4 6 uint Read 0 1,000,000,000

3204 2 4 7 uint Read 0 1,000,000,000

3206 2 4 8 uint Read 0 1,000,000,000

3208 2 5 1 uint Read 0 1,000,000,000

3210 2 5 2 uint Read 0 1,000,000,000

3212 2 5 3 uint Read 0 1,000,000,000

3214 2 5 4 uint Read 0 1,000,000,000

3216 2 5 5 uint Read 0 1,000,000,000

3218 2 5 6 uint Read 0 1,000,000,000

3220 2 5 7 uint Read 0 1,000,000,000

3222 2 5 8 uint Read 0 1,000,000,000

3224 2 6 1 uint Read 0 1,000,000,000

3226 2 6 2 uint Read 0 1,000,000,000

3228 2 6 3 uint Read 0 1,000,000,000

3230 2 6 4 uint Read 0 1,000,000,000

3232 2 6 5 uint Read 0 1,000,000,000

3234 2 6 6 uint Read 0 1,000,000,000

3236 2 6 7 uint Read 0 1,000,000,000

3238 2 6 8 uint Read 0 1,000,000,000

3240 2 7 1 uint Read 0 1,000,000,000

3242 2 7 2 uint Read 0 1,000,000,000

3244 2 7 3 uint Read 0 1,000,000,000

3246 2 7 4 uint Read 0 1,000,000,000

3248 2 7 5 uint Read 0 1,000,000,000

3250 2 7 6 uint Read 0 1,000,000,000

3252 2 7 7 uint Read 0 1,000,000,000

3254 2 7 8 uint Read 0 1,000,000,000

3256 2 8 1 uint Read 0 1,000,000,000

3258 2 8 2 uint Read 0 1,000,000,000

3260 2 8 3 uint Read 0 1,000,000,000

3262 2 8 4 uint Read 0 1,000,000,000

3264 2 8 5 uint Read 0 1,000,000,000

3266 2 8 6 uint Read 0 1,000,000,000

3268 2 8 7 uint Read 0 1,000,000,000

3270 2 8 8 uint Read 0 1,000,000,000

3272 2 9 1 uint Read 0 1,000,000,000

3274 2 9 2 uint Read 0 1,000,000,000

Page 53: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

51

Register Length Preset Component Data Type Read/Write Min Value Max Value

3276 2 9 3 uint Read 0 1,000,000,000

3278 2 9 4 uint Read 0 1,000,000,000

3280 2 9 5 uint Read 0 1,000,000,000

3282 2 9 6 uint Read 0 1,000,000,000

3284 2 9 7 uint Read 0 1,000,000,000

3286 2 9 8 uint Read 0 1,000,000,000

3288 2 10 1 uint Read 0 1,000,000,000

3290 2 10 2 uint Read 0 1,000,000,000

3292 2 10 3 uint Read 0 1,000,000,000

3294 2 10 4 uint Read 0 1,000,000,000

3296 2 10 5 uint Read 0 1,000,000,000

3298 2 10 6 uint Read 0 1,000,000,000

3300 2 10 7 uint Read 0 1,000,000,000

3302 2 10 8 uint Read 0 1,000,000,000

3304 2 11 1 uint Read 0 1,000,000,000

3306 2 11 2 uint Read 0 1,000,000,000

3308 2 11 3 uint Read 0 1,000,000,000

3310 2 11 4 uint Read 0 1,000,000,000

3312 2 11 5 uint Read 0 1,000,000,000

3314 2 11 6 uint Read 0 1,000,000,000

3316 2 11 7 uint Read 0 1,000,000,000

3318 2 11 8 uint Read 0 1,000,000,000

3320 2 12 1 uint Read 0 1,000,000,000

3322 2 12 2 uint Read 0 1,000,000,000

3324 2 12 3 uint Read 0 1,000,000,000

3326 2 12 4 uint Read 0 1,000,000,000

3328 2 12 5 uint Read 0 1,000,000,000

3330 2 12 6 uint Read 0 1,000,000,000

3332 2 12 7 uint Read 0 1,000,000,000

3334 2 12 8 uint Read 0 1,000,000,000

5.1.4 Real-Time Additive Gross Totalizer

Register Length Preset Additive Data Type Read/Write Min Value Max Value

3336 2 1 1 uint Read 0 1,000,000,000

3338 2 1 2 uint Read 0 1,000,000,000

3340 2 1 3 uint Read 0 1,000,000,000

3342 2 1 4 uint Read 0 1,000,000,000

3344 2 1 5 uint Read 0 1,000,000,000

3346 2 1 6 uint Read 0 1,000,000,000

Page 54: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

52

Register Length Preset Additive Data Type Read/Write Min Value Max Value

3348 2 1 7 uint Read 0 1,000,000,000

3350 2 1 8 uint Read 0 1,000,000,000

3352 2 1 9 uint Read 0 1,000,000,000

3354 2 1 10 uint Read 0 1,000,000,000

3356 2 1 11 uint Read 0 1,000,000,000

3358 2 1 12 uint Read 0 1,000,000,000

3360 2 1 13 uint Read 0 1,000,000,000

3362 2 1 14 uint Read 0 1,000,000,000

3364 2 1 15 uint Read 0 1,000,000,000

3366 2 1 16 uint Read 0 1,000,000,000

3368 2 2 1 uint Read 0 1,000,000,000

3370 2 2 2 uint Read 0 1,000,000,000

3372 2 2 3 uint Read 0 1,000,000,000

3374 2 2 4 uint Read 0 1,000,000,000

3376 2 2 5 uint Read 0 1,000,000,000

3378 2 2 6 uint Read 0 1,000,000,000

3380 2 2 7 uint Read 0 1,000,000,000

3382 2 2 8 uint Read 0 1,000,000,000

3384 2 2 9 uint Read 0 1,000,000,000

3386 2 2 10 uint Read 0 1,000,000,000

3388 2 2 11 uint Read 0 1,000,000,000

3390 2 2 12 uint Read 0 1,000,000,000

3392 2 2 13 uint Read 0 1,000,000,000

3394 2 2 14 uint Read 0 1,000,000,000

3396 2 2 15 uint Read 0 1,000,000,000

3398 2 2 16 uint Read 0 1,000,000,000

3400 2 3 1 uint Read 0 1,000,000,000

3402 2 3 2 uint Read 0 1,000,000,000

3404 2 3 3 uint Read 0 1,000,000,000

3406 2 3 4 uint Read 0 1,000,000,000

3408 2 3 5 uint Read 0 1,000,000,000

3410 2 3 6 uint Read 0 1,000,000,000

3412 2 3 7 uint Read 0 1,000,000,000

3414 2 3 8 uint Read 0 1,000,000,000

3416 2 3 9 uint Read 0 1,000,000,000

3418 2 3 10 uint Read 0 1,000,000,000

3420 2 3 11 uint Read 0 1,000,000,000

3422 2 3 12 uint Read 0 1,000,000,000

3424 2 3 13 uint Read 0 1,000,000,000

3426 2 3 14 uint Read 0 1,000,000,000

3428 2 3 15 uint Read 0 1,000,000,000

Page 55: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

53

Register Length Preset Additive Data Type Read/Write Min Value Max Value

3430 2 3 16 uint Read 0 1,000,000,000

3432 2 4 1 uint Read 0 1,000,000,000

3434 2 4 2 uint Read 0 1,000,000,000

3436 2 4 3 uint Read 0 1,000,000,000

3438 2 4 4 uint Read 0 1,000,000,000

3440 2 4 5 uint Read 0 1,000,000,000

3442 2 4 6 uint Read 0 1,000,000,000

3444 2 4 7 uint Read 0 1,000,000,000

3446 2 4 8 uint Read 0 1,000,000,000

3448 2 4 9 uint Read 0 1,000,000,000

3450 2 4 10 uint Read 0 1,000,000,000

3452 2 4 11 uint Read 0 1,000,000,000

3454 2 4 12 uint Read 0 1,000,000,000

3456 2 4 13 uint Read 0 1,000,000,000

3458 2 4 14 uint Read 0 1,000,000,000

3460 2 4 15 uint Read 0 1,000,000,000

3462 2 4 16 uint Read 0 1,000,000,000

3464 2 5 1 uint Read 0 1,000,000,000

3466 2 5 2 uint Read 0 1,000,000,000

3468 2 5 3 uint Read 0 1,000,000,000

3470 2 5 4 uint Read 0 1,000,000,000

3472 2 5 5 uint Read 0 1,000,000,000

3474 2 5 6 uint Read 0 1,000,000,000

3476 2 5 7 uint Read 0 1,000,000,000

3478 2 5 8 uint Read 0 1,000,000,000

3480 2 5 9 uint Read 0 1,000,000,000

3482 2 5 10 uint Read 0 1,000,000,000

3484 2 5 11 uint Read 0 1,000,000,000

3486 2 5 12 uint Read 0 1,000,000,000

3488 2 5 13 uint Read 0 1,000,000,000

3490 2 5 14 uint Read 0 1,000,000,000

3492 2 5 15 uint Read 0 1,000,000,000

3494 2 5 16 uint Read 0 1,000,000,000

3496 2 6 1 uint Read 0 1,000,000,000

3498 2 6 2 uint Read 0 1,000,000,000

3500 2 6 3 uint Read 0 1,000,000,000

3502 2 6 4 uint Read 0 1,000,000,000

3504 2 6 5 uint Read 0 1,000,000,000

3506 2 6 6 uint Read 0 1,000,000,000

3508 2 6 7 uint Read 0 1,000,000,000

3510 2 6 8 uint Read 0 1,000,000,000

Page 56: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

54

Register Length Preset Additive Data Type Read/Write Min Value Max Value

3512 2 6 9 uint Read 0 1,000,000,000

3514 2 6 10 uint Read 0 1,000,000,000

3516 2 6 11 uint Read 0 1,000,000,000

3518 2 6 12 uint Read 0 1,000,000,000

3520 2 6 13 uint Read 0 1,000,000,000

3522 2 6 14 uint Read 0 1,000,000,000

3524 2 6 15 uint Read 0 1,000,000,000

3526 2 6 16 uint Read 0 1,000,000,000

3528 2 7 1 uint Read 0 1,000,000,000

3530 2 7 2 uint Read 0 1,000,000,000

3532 2 7 3 uint Read 0 1,000,000,000

3534 2 7 4 uint Read 0 1,000,000,000

3536 2 7 5 uint Read 0 1,000,000,000

3538 2 7 6 uint Read 0 1,000,000,000

3540 2 7 7 uint Read 0 1,000,000,000

3542 2 7 8 uint Read 0 1,000,000,000

3544 2 7 9 uint Read 0 1,000,000,000

3546 2 7 10 uint Read 0 1,000,000,000

3548 2 7 11 uint Read 0 1,000,000,000

3550 2 7 12 uint Read 0 1,000,000,000

3552 2 7 13 uint Read 0 1,000,000,000

3554 2 7 14 uint Read 0 1,000,000,000

3556 2 7 15 uint Read 0 1,000,000,000

3558 2 7 16 uint Read 0 1,000,000,000

3560 2 8 1 uint Read 0 1,000,000,000

3562 2 8 2 uint Read 0 1,000,000,000

3564 2 8 3 uint Read 0 1,000,000,000

3566 2 8 4 uint Read 0 1,000,000,000

3568 2 8 5 uint Read 0 1,000,000,000

3570 2 8 6 uint Read 0 1,000,000,000

3572 2 8 7 uint Read 0 1,000,000,000

3574 2 8 8 uint Read 0 1,000,000,000

3576 2 8 9 uint Read 0 1,000,000,000

3578 2 8 10 uint Read 0 1,000,000,000

3580 2 8 11 uint Read 0 1,000,000,000

3582 2 8 12 uint Read 0 1,000,000,000

3584 2 8 13 uint Read 0 1,000,000,000

3586 2 8 14 uint Read 0 1,000,000,000

3588 2 8 15 uint Read 0 1,000,000,000

3590 2 8 16 uint Read 0 1,000,000,000

3592 2 9 1 uint Read 0 1,000,000,000

Page 57: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

55

Register Length Preset Additive Data Type Read/Write Min Value Max Value

3594 2 9 2 uint Read 0 1,000,000,000

3596 2 9 3 uint Read 0 1,000,000,000

3598 2 9 4 uint Read 0 1,000,000,000

3600 2 9 5 uint Read 0 1,000,000,000

3602 2 9 6 uint Read 0 1,000,000,000

3604 2 9 7 uint Read 0 1,000,000,000

3606 2 9 8 uint Read 0 1,000,000,000

3608 2 9 9 uint Read 0 1,000,000,000

3610 2 9 10 uint Read 0 1,000,000,000

3612 2 9 11 uint Read 0 1,000,000,000

3614 2 9 12 uint Read 0 1,000,000,000

3616 2 9 13 uint Read 0 1,000,000,000

3618 2 9 14 uint Read 0 1,000,000,000

3620 2 9 15 uint Read 0 1,000,000,000

3622 2 9 16 uint Read 0 1,000,000,000

3624 2 10 1 uint Read 0 1,000,000,000

3626 2 10 2 uint Read 0 1,000,000,000

3628 2 10 3 uint Read 0 1,000,000,000

3630 2 10 4 uint Read 0 1,000,000,000

3632 2 10 5 uint Read 0 1,000,000,000

3634 2 10 6 uint Read 0 1,000,000,000

3636 2 10 7 uint Read 0 1,000,000,000

3638 2 10 8 uint Read 0 1,000,000,000

3640 2 10 9 uint Read 0 1,000,000,000

3642 2 10 10 uint Read 0 1,000,000,000

3644 2 10 11 uint Read 0 1,000,000,000

3646 2 10 12 uint Read 0 1,000,000,000

3648 2 10 13 uint Read 0 1,000,000,000

3650 2 10 14 uint Read 0 1,000,000,000

3652 2 10 15 uint Read 0 1,000,000,000

3654 2 10 16 uint Read 0 1,000,000,000

3656 2 11 1 uint Read 0 1,000,000,000

3658 2 11 2 uint Read 0 1,000,000,000

3660 2 11 3 uint Read 0 1,000,000,000

3662 2 11 4 uint Read 0 1,000,000,000

3664 2 11 5 uint Read 0 1,000,000,000

3666 2 11 6 uint Read 0 1,000,000,000

3668 2 11 7 uint Read 0 1,000,000,000

3670 2 11 8 uint Read 0 1,000,000,000

3672 2 11 9 uint Read 0 1,000,000,000

3674 2 11 10 uint Read 0 1,000,000,000

Page 58: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

56

Register Length Preset Additive Data Type Read/Write Min Value Max Value

3676 2 11 11 uint Read 0 1,000,000,000

3678 2 11 12 uint Read 0 1,000,000,000

3680 2 11 13 uint Read 0 1,000,000,000

3682 2 11 14 uint Read 0 1,000,000,000

3684 2 11 15 uint Read 0 1,000,000,000

3686 2 11 16 uint Read 0 1,000,000,000

3688 2 12 1 uint Read 0 1,000,000,000

3690 2 12 2 uint Read 0 1,000,000,000

3692 2 12 3 uint Read 0 1,000,000,000

3694 2 12 4 uint Read 0 1,000,000,000

3696 2 12 5 uint Read 0 1,000,000,000

3698 2 12 6 uint Read 0 1,000,000,000

3700 2 12 7 uint Read 0 1,000,000,000

3702 2 12 8 uint Read 0 1,000,000,000

3704 2 12 9 uint Read 0 1,000,000,000

3706 2 12 10 uint Read 0 1,000,000,000

3708 2 12 11 uint Read 0 1,000,000,000

3710 2 12 12 uint Read 0 1,000,000,000

3712 2 12 13 uint Read 0 1,000,000,000

3714 2 12 14 uint Read 0 1,000,000,000

3716 2 12 15 uint Read 0 1,000,000,000

3718 2 12 16 uint Read 0 1,000,000,000

5.1.5 Real-Time Preset Net Totalizer

Register Length Preset Data Type Read/Write Min Value Max Value

3720 2 1 uint Read 0 1,000,000,000

3722 2 2 uint Read 0 1,000,000,000

3724 2 3 uint Read 0 1,000,000,000

3726 2 4 uint Read 0 1,000,000,000

3728 2 5 uint Read 0 1,000,000,000

3730 2 6 uint Read 0 1,000,000,000

3732 2 7 uint Read 0 1,000,000,000

3734 2 8 uint Read 0 1,000,000,000

3736 2 9 uint Read 0 1,000,000,000

3738 2 10 uint Read 0 1,000,000,000

3740 2 11 uint Read 0 1,000,000,000

3742 2 12 uint Read 0 1,000,000,000

Page 59: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

57

5.1.6 Real-Time Component Net Totalizer

Register Length Preset Component Data Type Read/Write Min Value Max Value

3744 2 1 1 uint Read 0 1,000,000,000

3746 2 1 2 uint Read 0 1,000,000,000

3748 2 1 3 uint Read 0 1,000,000,000

3750 2 1 4 uint Read 0 1,000,000,000

3752 2 1 5 uint Read 0 1,000,000,000

3754 2 1 6 uint Read 0 1,000,000,000

3756 2 1 7 uint Read 0 1,000,000,000

3758 2 1 8 uint Read 0 1,000,000,000

3760 2 2 1 uint Read 0 1,000,000,000

3762 2 2 2 uint Read 0 1,000,000,000

3764 2 2 3 uint Read 0 1,000,000,000

3766 2 2 4 uint Read 0 1,000,000,000

3768 2 2 5 uint Read 0 1,000,000,000

3770 2 2 6 uint Read 0 1,000,000,000

3772 2 2 7 uint Read 0 1,000,000,000

3774 2 2 8 uint Read 0 1,000,000,000

3776 2 3 1 uint Read 0 1,000,000,000

3778 2 3 2 uint Read 0 1,000,000,000

3780 2 3 3 uint Read 0 1,000,000,000

3782 2 3 4 uint Read 0 1,000,000,000

3784 2 3 5 uint Read 0 1,000,000,000

3786 2 3 6 uint Read 0 1,000,000,000

3788 2 3 7 uint Read 0 1,000,000,000

3790 2 3 8 uint Read 0 1,000,000,000

3792 2 4 1 uint Read 0 1,000,000,000

3794 2 4 2 uint Read 0 1,000,000,000

3796 2 4 3 uint Read 0 1,000,000,000

3798 2 4 4 uint Read 0 1,000,000,000

3800 2 4 5 uint Read 0 1,000,000,000

3802 2 4 6 uint Read 0 1,000,000,000

3804 2 4 7 uint Read 0 1,000,000,000

3806 2 4 8 uint Read 0 1,000,000,000

3808 2 5 1 uint Read 0 1,000,000,000

3810 2 5 2 uint Read 0 1,000,000,000

3812 2 5 3 uint Read 0 1,000,000,000

3814 2 5 4 uint Read 0 1,000,000,000

3816 2 5 5 uint Read 0 1,000,000,000

3818 2 5 6 uint Read 0 1,000,000,000

Page 60: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

58

Register Length Preset Component Data Type Read/Write Min Value Max Value

3820 2 5 7 uint Read 0 1,000,000,000

3822 2 5 8 uint Read 0 1,000,000,000

3824 2 6 1 uint Read 0 1,000,000,000

3826 2 6 2 uint Read 0 1,000,000,000

3828 2 6 3 uint Read 0 1,000,000,000

3830 2 6 4 uint Read 0 1,000,000,000

3832 2 6 5 uint Read 0 1,000,000,000

3834 2 6 6 uint Read 0 1,000,000,000

3836 2 6 7 uint Read 0 1,000,000,000

3838 2 6 8 uint Read 0 1,000,000,000

3840 2 7 1 uint Read 0 1,000,000,000

3842 2 7 2 uint Read 0 1,000,000,000

3844 2 7 3 uint Read 0 1,000,000,000

3846 2 7 4 uint Read 0 1,000,000,000

3848 2 7 5 uint Read 0 1,000,000,000

3850 2 7 6 uint Read 0 1,000,000,000

3852 2 7 7 uint Read 0 1,000,000,000

3854 2 7 8 uint Read 0 1,000,000,000

3856 2 8 1 uint Read 0 1,000,000,000

3858 2 8 2 uint Read 0 1,000,000,000

3860 2 8 3 uint Read 0 1,000,000,000

3862 2 8 4 uint Read 0 1,000,000,000

3864 2 8 5 uint Read 0 1,000,000,000

3866 2 8 6 uint Read 0 1,000,000,000

3868 2 8 7 uint Read 0 1,000,000,000

3870 2 8 8 uint Read 0 1,000,000,000

3872 2 9 1 uint Read 0 1,000,000,000

3874 2 9 2 uint Read 0 1,000,000,000

3876 2 9 3 uint Read 0 1,000,000,000

3878 2 9 4 uint Read 0 1,000,000,000

3880 2 9 5 uint Read 0 1,000,000,000

3882 2 9 6 uint Read 0 1,000,000,000

3884 2 9 7 uint Read 0 1,000,000,000

3886 2 9 8 uint Read 0 1,000,000,000

3888 2 10 1 uint Read 0 1,000,000,000

3890 2 10 2 uint Read 0 1,000,000,000

3892 2 10 3 uint Read 0 1,000,000,000

3894 2 10 4 uint Read 0 1,000,000,000

3896 2 10 5 uint Read 0 1,000,000,000

3898 2 10 6 uint Read 0 1,000,000,000

3900 2 10 7 uint Read 0 1,000,000,000

Page 61: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

59

Register Length Preset Component Data Type Read/Write Min Value Max Value

3902 2 10 8 uint Read 0 1,000,000,000

3904 2 11 1 uint Read 0 1,000,000,000

3906 2 11 2 uint Read 0 1,000,000,000

3908 2 11 3 uint Read 0 1,000,000,000

3910 2 11 4 uint Read 0 1,000,000,000

3912 2 11 5 uint Read 0 1,000,000,000

3914 2 11 6 uint Read 0 1,000,000,000

3916 2 11 7 uint Read 0 1,000,000,000

3918 2 11 8 uint Read 0 1,000,000,000

3920 2 12 1 uint Read 0 1,000,000,000

3922 2 12 2 uint Read 0 1,000,000,000

3924 2 12 3 uint Read 0 1,000,000,000

3926 2 12 4 uint Read 0 1,000,000,000

3928 2 12 5 uint Read 0 1,000,000,000

3930 2 12 6 uint Read 0 1,000,000,000

3932 2 12 7 uint Read 0 1,000,000,000

3934 2 12 8 uint Read 0 1,000,000,000

5.1.7 Real-Time Preset Mass Totalizer

Register Length Preset Data Type Read/Write Min Value Max Value

11720 2 1 Read uint 0 1,000,000,000

11722 2 2 Read uint 0 1,000,000,000

11724 2 3 Read uint 0 1,000,000,000

11726 2 4 Read uint 0 1,000,000,000

11728 2 5 Read uint 0 1,000,000,000

11730 2 6 Read uint 0 1,000,000,000

11732 2 7 Read uint 0 1,000,000,000

11734 2 8 Read uint 0 1,000,000,000

11736 2 9 Read uint 0 1,000,000,000

11738 2 10 Read uint 0 1,000,000,000

11740 2 11 Read uint 0 1,000,000,000

11742 2 12 Read uint 0 1,000,000,000

5.1.8 Real-Time Component Mass Totalizer

Register Length Preset Meter Data Type Read/Write Min Value Max Value

11744 2 1 1 Read uint 0 1,000,000,000

11746 2 1 2 Read uint 0 1,000,000,000

11748 2 1 3 Read uint 0 1,000,000,000

Page 62: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

60

Register Length Preset Meter Data Type Read/Write Min Value Max Value

11750 2 1 4 Read uint 0 1,000,000,000

11752 2 1 5 Read uint 0 1,000,000,000

11754 2 1 6 Read uint 0 1,000,000,000

11756 2 1 7 Read uint 0 1,000,000,000

11758 2 1 8 Read uint 0 1,000,000,000

11760 2 2 1 Read uint 0 1,000,000,000

11762 2 2 2 Read uint 0 1,000,000,000

11764 2 2 3 Read uint 0 1,000,000,000

11766 2 2 4 Read uint 0 1,000,000,000

11768 2 2 5 Read uint 0 1,000,000,000

11770 2 2 6 Read uint 0 1,000,000,000

11772 2 2 7 Read uint 0 1,000,000,000

11774 2 2 8 Read uint 0 1,000,000,000

11776 2 3 1 Read uint 0 1,000,000,000

11778 2 3 2 Read uint 0 1,000,000,000

11780 2 3 3 Read uint 0 1,000,000,000

11782 2 3 4 Read uint 0 1,000,000,000

11784 2 3 5 Read uint 0 1,000,000,000

11786 2 3 6 Read uint 0 1,000,000,000

11788 2 3 7 Read uint 0 1,000,000,000

11790 2 3 8 Read uint 0 1,000,000,000

11792 2 4 1 Read uint 0 1,000,000,000

11794 2 4 2 Read uint 0 1,000,000,000

11796 2 4 3 Read uint 0 1,000,000,000

11798 2 4 4 Read uint 0 1,000,000,000

11800 2 4 5 Read uint 0 1,000,000,000

11802 2 4 6 Read uint 0 1,000,000,000

11804 2 4 7 Read uint 0 1,000,000,000

11806 2 4 8 Read uint 0 1,000,000,000

11808 2 5 1 Read uint 0 1,000,000,000

11810 2 5 2 Read uint 0 1,000,000,000

11812 2 5 3 Read uint 0 1,000,000,000

11814 2 5 4 Read uint 0 1,000,000,000

11816 2 5 5 Read uint 0 1,000,000,000

11818 2 5 6 Read uint 0 1,000,000,000

11820 2 5 7 Read uint 0 1,000,000,000

11822 2 5 8 Read uint 0 1,000,000,000

11824 2 6 1 Read uint 0 1,000,000,000

11826 2 6 2 Read uint 0 1,000,000,000

11828 2 6 3 Read uint 0 1,000,000,000

11830 2 6 4 Read uint 0 1,000,000,000

Page 63: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

61

Register Length Preset Meter Data Type Read/Write Min Value Max Value

11832 2 6 5 Read uint 0 1,000,000,000

11834 2 6 6 Read uint 0 1,000,000,000

11836 2 6 7 Read uint 0 1,000,000,000

11838 2 6 8 Read uint 0 1,000,000,000

11840 2 7 1 Read uint 0 1,000,000,000

11842 2 7 2 Read uint 0 1,000,000,000

11844 2 7 3 Read uint 0 1,000,000,000

11846 2 7 4 Read uint 0 1,000,000,000

11848 2 7 5 Read uint 0 1,000,000,000

11850 2 7 6 Read uint 0 1,000,000,000

11852 2 7 7 Read uint 0 1,000,000,000

11854 2 7 8 Read uint 0 1,000,000,000

11856 2 8 1 Read uint 0 1,000,000,000

11858 2 8 2 Read uint 0 1,000,000,000

11860 2 8 3 Read uint 0 1,000,000,000

11862 2 8 4 Read uint 0 1,000,000,000

11864 2 8 5 Read uint 0 1,000,000,000

11866 2 8 6 Read uint 0 1,000,000,000

11868 2 8 7 Read uint 0 1,000,000,000

11870 2 8 8 Read uint 0 1,000,000,000

11872 2 9 1 Read uint 0 1,000,000,000

11874 2 9 2 Read uint 0 1,000,000,000

11876 2 9 3 Read uint 0 1,000,000,000

11878 2 9 4 Read uint 0 1,000,000,000

11880 2 9 5 Read uint 0 1,000,000,000

11882 2 9 6 Read uint 0 1,000,000,000

11884 2 9 7 Read uint 0 1,000,000,000

11886 2 9 8 Read uint 0 1,000,000,000

11888 2 10 1 Read uint 0 1,000,000,000

11890 2 10 2 Read uint 0 1,000,000,000

11892 2 10 3 Read uint 0 1,000,000,000

11894 2 10 4 Read uint 0 1,000,000,000

11896 2 10 5 Read uint 0 1,000,000,000

11898 2 10 6 Read uint 0 1,000,000,000

11900 2 10 7 Read uint 0 1,000,000,000

11902 2 10 8 Read uint 0 1,000,000,000

11904 2 11 1 Read uint 0 1,000,000,000

11906 2 11 2 Read uint 0 1,000,000,000

11908 2 11 3 Read uint 0 1,000,000,000

11910 2 11 4 Read uint 0 1,000,000,000

11912 2 11 5 Read uint 0 1,000,000,000

Page 64: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

62

Register Length Preset Meter Data Type Read/Write Min Value Max Value

11914 2 11 6 Read uint 0 1,000,000,000

11916 2 11 7 Read uint 0 1,000,000,000

11918 2 11 8 Read uint 0 1,000,000,000

11920 2 12 1 Read uint 0 1,000,000,000

11922 2 12 2 Read uint 0 1,000,000,000

11924 2 12 3 Read uint 0 1,000,000,000

11926 2 12 4 Read uint 0 1,000,000,000

11928 2 12 5 Read uint 0 1,000,000,000

11930 2 12 6 Read uint 0 1,000,000,000

11932 2 12 7 Read uint 0 1,000,000,000

11934 2 12 8 Read uint 0 1,000,000,000

Real-Time Value Registers

5.2.1 Preset quantity in whole units

Register Length Preset Data Type Read/Write Min Value Max Value

4036 2 1 uint Read 0 9,999,999

4038 2 2 uint Read 0 9,999,999

4040 2 3 uint Read 0 9,999,999

4042 2 4 uint Read 0 9,999,999

4044 2 5 uint Read 0 9,999,999

4046 2 6 uint Read 0 9,999,999

4048 2 7 uint Read 0 9,999,999

4050 2 8 uint Read 0 9,999,999

4052 2 9 uint Read 0 9,999,999

4054 2 10 uint Read 0 9,999,999

4056 2 11 uint Read 0 9,999,999

4058 2 12 uint Read 0 9,999,999

5.2.2 Preset Delivered Gross Quantity in Whole Units

Register Length Preset Data Type Read/Write Min Value Max Value

4060 2 1 uint Read 0 9,999,999

4062 2 2 uint Read 0 9,999,999

4064 2 3 uint Read 0 9,999,999

4066 2 4 uint Read 0 9,999,999

4068 2 5 uint Read 0 9,999,999

4070 2 6 uint Read 0 9,999,999

4072 2 7 uint Read 0 9,999,999

4074 2 8 uint Read 0 9,999,999

Page 65: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

63

Register Length Preset Data Type Read/Write Min Value Max Value

4076 2 9 uint Read 0 9,999,999

4078 2 10 uint Read 0 9,999,999

4080 2 11 uint Read 0 9,999,999

4082 2 12 uint Read 0 9,999,999

5.2.3 Preset Delivered Net Quantity in Whole Units

Register Length Preset Data Type Read/Write Min Value Max Value

4084 2 1 uint Read 0 9,999,999

4086 2 2 uint Read 0 9,999,999

4088 2 3 uint Read 0 9,999,999

4090 2 4 uint Read 0 9,999,999

4092 2 5 uint Read 0 9,999,999

4094 2 6 uint Read 0 9,999,999

4096 2 7 uint Read 0 9,999,999

4098 2 8 uint Read 0 9,999,999

4100 2 9 uint Read 0 9,999,999

4102 2 10 uint Read 0 9,999,999

4104 2 11 uint Read 0 9,999,999

4106 2 12 uint Read 0 9,999,999

5.2.4 Preset Batch Average Temp in Tenths or Hundredths

Register Length Preset Data Type Read/Write Min Value Max Value

4108 2 1 int Read -50.00 350.00

4110 2 2 int Read -50.00 350.00

4112 2 3 int Read -50.00 350.00

4114 2 4 int Read -50.00 350.00

4116 2 5 int Read -50.00 350.00

4118 2 6 int Read -50.00 350.00

4120 2 7 int Read -50.00 350.00

4122 2 8 int Read -50.00 350.00

4124 2 9 int Read -50.00 350.00

4126 2 10 int Read -50.00 350.00

4128 2 11 int Read -50.00 350.00

4130 2 12 int Read -50.00 350.00

5.2.5 Batch Average Pressure in Tenths or Hundredths

Register Length Preset Data Type Read/Write Min Value Max Value

4132 2 1 int Read -20.00 650.00

Page 66: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

64

Register Length Preset Data Type Read/Write Min Value Max Value

4134 2 2 int Read -20.00 650.00

4136 2 3 int Read -20.00 650.00

4138 2 4 int Read -20.00 650.00

4140 2 5 int Read -20.00 650.00

4142 2 6 int Read -20.00 650.00

4144 2 7 int Read -20.00 650.00

4146 2 8 int Read -20.00 650.00

4148 2 9 int Read -20.00 650.00

4150 2 10 int Read -20.00 650.00

4152 2 11 int Read -20.00 650.00

4154 2 12 int Read -20.00 650.00

5.2.6 Preset Batch Average Density/Relative Density/Gravity

Register Length Preset Data Type Read/Write Min Value Max Value

4156 2 1 int Read -100.00 1200.00

4158 2 2 int Read -100.00 1200.00

4160 2 3 int Read -100.00 1200.00

4162 2 4 int Read -100.00 1200.00

4164 2 5 int Read -100.00 1200.00

4166 2 6 int Read -100.00 1200.00

4168 2 7 int Read -100.00 1200.00

4170 2 8 int Read -100.00 1200.00

4172 2 9 int Read -100.00 1200.00

4174 2 10 int Read -100.00 1200.00

4176 2 11 int Read -100.00 1200.00

4178 2 12 int Read -100.00 1200.00

5.2.7 Preset Gross Flow Rate in Whole Units

Register Length Preset Data Type Read/Write Min Value Max Value

4180 1 1 uint Read 0 65535

4181 1 2 uint Read 0 65535

4182 1 3 uint Read 0 65535

4183 1 4 uint Read 0 65535

4184 1 5 uint Read 0 65535

4185 1 6 uint Read 0 65535

4186 1 7 uint Read 0 65535

4187 1 8 uint Read 0 65535

4188 1 9 uint Read 0 65535

Page 67: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

65

Register Length Preset Data Type Read/Write Min Value Max Value

4189 1 10 uint Read 0 65535

4190 1 11 uint Read 0 65535

4191 1 12 uint Read 0 65535

5.2.8 Meter Delivered Gross Quantity in Whole Units

Register Length Preset Meter Data Type Read/Write Min Value Max Value

4192 2 1 1 uint Read 0 65535

4194 2 1 2 uint Read 0 65535

4196 2 1 3 uint Read 0 65535

4198 2 1 4 uint Read 0 65535

4200 2 1 5 uint Read 0 65535

4202 2 2 1 uint Read 0 65535

4204 2 2 2 uint Read 0 65535

4206 2 2 3 uint Read 0 65535

4208 2 2 4 uint Read 0 65535

4210 2 2 5 uint Read 0 65535

4212 2 3 1 uint Read 0 65535

4214 2 3 2 uint Read 0 65535

4216 2 3 3 uint Read 0 65535

4218 2 3 4 uint Read 0 65535

4220 2 3 5 uint Read 0 65535

4222 2 4 1 uint Read 0 65535

4224 2 4 2 uint Read 0 65535

4226 2 4 3 uint Read 0 65535

4228 2 4 4 uint Read 0 65535

4230 2 4 5 uint Read 0 65535

4232 2 5 1 uint Read 0 65535

4234 2 5 2 uint Read 0 65535

4236 2 5 3 uint Read 0 65535

4238 2 5 4 uint Read 0 65535

4240 2 5 5 uint Read 0 65535

4242 2 6 1 uint Read 0 65535

4244 2 6 2 uint Read 0 65535

4246 2 6 3 uint Read 0 65535

4248 2 6 4 uint Read 0 65535

4250 2 6 5 uint Read 0 65535

4252 2 7 1 uint Read 0 65535

4254 2 7 2 uint Read 0 65535

4256 2 7 3 uint Read 0 65535

4258 2 7 4 uint Read 0 65535

Page 68: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

66

Register Length Preset Meter Data Type Read/Write Min Value Max Value

4260 2 7 5 uint Read 0 65535

4262 2 8 1 uint Read 0 65535

4264 2 8 2 uint Read 0 65535

4266 2 8 3 uint Read 0 65535

4268 2 8 4 uint Read 0 65535

4270 2 8 5 uint Read 0 65535

4272 2 9 1 uint Read 0 65535

4274 2 9 2 uint Read 0 65535

4276 2 9 3 uint Read 0 65535

4278 2 9 4 uint Read 0 65535

4280 2 9 5 uint Read 0 65535

4282 2 10 1 uint Read 0 65535

4284 2 10 2 uint Read 0 65535

4286 2 10 3 uint Read 0 65535

4288 2 10 4 uint Read 0 65535

4290 2 10 5 uint Read 0 65535

4292 2 11 1 uint Read 0 65535

4294 2 11 2 uint Read 0 65535

4296 2 11 3 uint Read 0 65535

4298 2 11 4 uint Read 0 65535

4300 2 11 5 uint Read 0 65535

4302 2 12 1 uint Read 0 65535

4304 2 12 2 uint Read 0 65535

4306 2 12 3 uint Read 0 65535

4308 2 12 4 uint Read 0 65535

4310 2 12 5 uint Read 0 65535

5.2.9 Meter Gross Flow Rate in Whole Units

Register Length Preset Meter Data Type Read/Write Min Value Max Value

4312 1 1 1 uint Read 0 65535

4313 1 1 2 uint Read 0 65535

4314 1 1 3 uint Read 0 65535

4315 1 1 4 uint Read 0 65535

4316 1 1 5 uint Read 0 65535

4317 1 2 1 uint Read 0 65535

4318 1 2 2 uint Read 0 65535

4319 1 2 3 uint Read 0 65535

4320 1 2 4 uint Read 0 65535

4321 1 2 5 uint Read 0 65535

Page 69: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

67

Register Length Preset Meter Data Type Read/Write Min Value Max Value

4322 1 3 1 uint Read 0 65535

4323 1 3 2 uint Read 0 65535

4324 1 3 3 uint Read 0 65535

4325 1 3 4 uint Read 0 65535

4326 1 3 5 uint Read 0 65535

4327 1 4 1 uint Read 0 65535

4328 1 4 2 uint Read 0 65535

4329 1 4 3 uint Read 0 65535

4330 1 4 4 uint Read 0 65535

4331 1 4 5 uint Read 0 65535

4332 1 5 1 uint Read 0 65535

4333 1 5 2 uint Read 0 65535

4334 1 5 3 uint Read 0 65535

4335 1 5 4 uint Read 0 65535

4336 1 5 5 uint Read 0 65535

4337 1 6 1 uint Read 0 65535

4338 1 6 2 uint Read 0 65535

4339 1 6 3 uint Read 0 65535

4340 1 6 4 uint Read 0 65535

4341 1 6 5 uint Read 0 65535

4342 1 7 1 uint Read 0 65535

4343 1 7 2 uint Read 0 65535

4344 1 7 3 uint Read 0 65535

4345 1 7 4 uint Read 0 65535

4346 1 7 5 uint Read 0 65535

4347 1 8 1 uint Read 0 65535

4348 1 8 2 uint Read 0 65535

4349 1 8 3 uint Read 0 65535

4350 1 8 4 uint Read 0 65535

4351 1 8 5 uint Read 0 65535

4352 1 9 1 uint Read 0 65535

4353 1 9 2 uint Read 0 65535

4354 1 9 3 uint Read 0 65535

4355 1 9 4 uint Read 0 65535

4356 1 9 5 uint Read 0 65535

4357 1 10 1 uint Read 0 65535

4358 1 10 2 uint Read 0 65535

4359 1 10 3 uint Read 0 65535

4360 1 10 4 uint Read 0 65535

4361 1 10 5 uint Read 0 65535

4362 1 11 1 uint Read 0 65535

Page 70: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

68

Register Length Preset Meter Data Type Read/Write Min Value Max Value

4363 1 11 2 uint Read 0 65535

4364 1 11 3 uint Read 0 65535

4365 1 11 4 uint Read 0 65535

4366 1 11 5 uint Read 0 65535

4367 1 12 1 uint Read 0 65535

4368 1 12 2 uint Read 0 65535

4369 1 12 3 uint Read 0 65535

4370 1 12 4 uint Read 0 65535

4371 1 12 5 uint Read 0 65535

5.2.10 Component Delivered Gross Quantity in Whole Units

Register Length Preset Component Data Type Read/Write Min Value Max Value

4372 2 1 1 uint Read 0 65535

4374 2 1 2 uint Read 0 65535

4376 2 1 3 uint Read 0 65535

4378 2 1 4 uint Read 0 65535

4380 2 1 5 uint Read 0 65535

4382 2 1 6 uint Read 0 65535

4384 2 1 7 uint Read 0 65535

4386 2 1 8 uint Read 0 65535

4388 2 2 1 uint Read 0 65535

4390 2 2 2 uint Read 0 65535

4392 2 2 3 uint Read 0 65535

4394 2 2 4 uint Read 0 65535

4396 2 2 5 uint Read 0 65535

4398 2 2 6 uint Read 0 65535

4400 2 2 7 uint Read 0 65535

4402 2 2 8 uint Read 0 65535

4404 2 3 1 uint Read 0 65535

4406 2 3 2 uint Read 0 65535

4408 2 3 3 uint Read 0 65535

4410 2 3 4 uint Read 0 65535

4412 2 3 5 uint Read 0 65535

4414 2 3 6 uint Read 0 65535

4416 2 3 7 uint Read 0 65535

4418 2 3 8 uint Read 0 65535

4420 2 4 1 uint Read 0 65535

4422 2 4 2 uint Read 0 65535

4424 2 4 3 uint Read 0 65535

Page 71: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

69

Register Length Preset Component Data Type Read/Write Min Value Max Value

4426 2 4 4 uint Read 0 65535

4428 2 4 5 uint Read 0 65535

4430 2 4 6 uint Read 0 65535

4432 2 4 7 uint Read 0 65535

4434 2 4 8 uint Read 0 65535

4436 2 5 1 uint Read 0 65535

4438 2 5 2 uint Read 0 65535

4440 2 5 3 uint Read 0 65535

4442 2 5 4 uint Read 0 65535

4444 2 5 5 uint Read 0 65535

4446 2 5 6 uint Read 0 65535

4448 2 5 7 uint Read 0 65535

4450 2 5 8 uint Read 0 65535

4452 2 6 1 uint Read 0 65535

4454 2 6 2 uint Read 0 65535

4456 2 6 3 uint Read 0 65535

4458 2 6 4 uint Read 0 65535

4460 2 6 5 uint Read 0 65535

4462 2 6 6 uint Read 0 65535

4464 2 6 7 uint Read 0 65535

4466 2 6 8 uint Read 0 65535

4468 2 7 1 uint Read 0 65535

4470 2 7 2 uint Read 0 65535

4472 2 7 3 uint Read 0 65535

4474 2 7 4 uint Read 0 65535

4476 2 7 5 uint Read 0 65535

4478 2 7 6 uint Read 0 65535

4480 2 7 7 uint Read 0 65535

4482 2 7 8 uint Read 0 65535

4484 2 8 1 uint Read 0 65535

4486 2 8 2 uint Read 0 65535

4488 2 8 3 uint Read 0 65535

4490 2 8 4 uint Read 0 65535

4492 2 8 5 uint Read 0 65535

4494 2 8 6 uint Read 0 65535

4496 2 8 7 uint Read 0 65535

4498 2 8 8 uint Read 0 65535

4500 2 9 1 uint Read 0 65535

4502 2 9 2 uint Read 0 65535

4504 2 9 3 uint Read 0 65535

4506 2 9 4 uint Read 0 65535

Page 72: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

70

Register Length Preset Component Data Type Read/Write Min Value Max Value

4508 2 9 5 uint Read 0 65535

4510 2 9 6 uint Read 0 65535

4512 2 9 7 uint Read 0 65535

4514 2 9 8 uint Read 0 65535

4516 2 10 1 uint Read 0 65535

4518 2 10 2 uint Read 0 65535

4520 2 10 3 uint Read 0 65535

4522 2 10 4 uint Read 0 65535

4524 2 10 5 uint Read 0 65535

4526 2 10 6 uint Read 0 65535

4528 2 10 7 uint Read 0 65535

4530 2 10 8 uint Read 0 65535

4532 2 11 1 uint Read 0 65535

4534 2 11 2 uint Read 0 65535

4536 2 11 3 uint Read 0 65535

4538 2 11 4 uint Read 0 65535

4540 2 11 5 uint Read 0 65535

4542 2 11 6 uint Read 0 65535

4544 2 11 7 uint Read 0 65535

4546 2 11 8 uint Read 0 65535

4548 2 12 1 uint Read 0 65535

4550 2 12 2 uint Read 0 65535

4552 2 12 3 uint Read 0 65535

4554 2 12 4 uint Read 0 65535

4556 2 12 5 uint Read 0 65535

4558 2 12 6 uint Read 0 65535

4560 2 12 7 uint Read 0 65535

4562 2 12 8 uint Read 0 65535

5.2.11 Component Delivered Net Quantity in Whole Units

Register Length Preset Component Data Type Read/Write Min Value Max Value

4564 2 1 1 uint Read 0 65535

4566 2 1 2 uint Read 0 65535

4568 2 1 3 uint Read 0 65535

4570 2 1 4 uint Read 0 65535

4572 2 1 5 uint Read 0 65535

4574 2 1 6 uint Read 0 65535

4576 2 1 7 uint Read 0 65535

4578 2 1 8 uint Read 0 65535

4580 2 2 1 uint Read 0 65535

Page 73: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

71

Register Length Preset Component Data Type Read/Write Min Value Max Value

4582 2 2 2 uint Read 0 65535

4584 2 2 3 uint Read 0 65535

4586 2 2 4 uint Read 0 65535

4588 2 2 5 uint Read 0 65535

4590 2 2 6 uint Read 0 65535

4592 2 2 7 uint Read 0 65535

4594 2 2 8 uint Read 0 65535

4596 2 3 1 uint Read 0 65535

4598 2 3 2 uint Read 0 65535

4600 2 3 3 uint Read 0 65535

4602 2 3 4 uint Read 0 65535

4604 2 3 5 uint Read 0 65535

4606 2 3 6 uint Read 0 65535

4608 2 3 7 uint Read 0 65535

4610 2 3 8 uint Read 0 65535

4612 2 4 1 uint Read 0 65535

4614 2 4 2 uint Read 0 65535

4616 2 4 3 uint Read 0 65535

4618 2 4 4 uint Read 0 65535

4620 2 4 5 uint Read 0 65535

4622 2 4 6 uint Read 0 65535

4624 2 4 7 uint Read 0 65535

4626 2 4 8 uint Read 0 65535

4628 2 5 1 uint Read 0 65535

4630 2 5 2 uint Read 0 65535

4632 2 5 3 uint Read 0 65535

4634 2 5 4 uint Read 0 65535

4636 2 5 5 uint Read 0 65535

4638 2 5 6 uint Read 0 65535

4640 2 5 7 uint Read 0 65535

4642 2 5 8 uint Read 0 65535

4644 2 6 1 uint Read 0 65535

4646 2 6 2 uint Read 0 65535

4648 2 6 3 uint Read 0 65535

4650 2 6 4 uint Read 0 65535

4652 2 6 5 uint Read 0 65535

4654 2 6 6 uint Read 0 65535

4656 2 6 7 uint Read 0 65535

4658 2 6 8 uint Read 0 65535

4660 2 7 1 uint Read 0 65535

4662 2 7 2 uint Read 0 65535

Page 74: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

72

Register Length Preset Component Data Type Read/Write Min Value Max Value

4664 2 7 3 uint Read 0 65535

4666 2 7 4 uint Read 0 65535

4668 2 7 5 uint Read 0 65535

4670 2 7 6 uint Read 0 65535

4672 2 7 7 uint Read 0 65535

4674 2 7 8 uint Read 0 65535

4676 2 8 1 uint Read 0 65535

4678 2 8 2 uint Read 0 65535

4680 2 8 3 uint Read 0 65535

4682 2 8 4 uint Read 0 65535

4684 2 8 5 uint Read 0 65535

4686 2 8 6 uint Read 0 65535

4688 2 8 7 uint Read 0 65535

4690 2 8 8 uint Read 0 65535

4692 2 9 1 uint Read 0 65535

4694 2 9 2 uint Read 0 65535

4696 2 9 3 uint Read 0 65535

4698 2 9 4 uint Read 0 65535

4700 2 9 5 uint Read 0 65535

4702 2 9 6 uint Read 0 65535

4704 2 9 7 uint Read 0 65535

4706 2 9 8 uint Read 0 65535

4708 2 10 1 uint Read 0 65535

4710 2 10 2 uint Read 0 65535

4712 2 10 3 uint Read 0 65535

4714 2 10 4 uint Read 0 65535

4716 2 10 5 uint Read 0 65535

4718 2 10 6 uint Read 0 65535

4720 2 10 7 uint Read 0 65535

4722 2 10 8 uint Read 0 65535

4724 2 11 1 uint Read 0 65535

4726 2 11 2 uint Read 0 65535

4728 2 11 3 uint Read 0 65535

4730 2 11 4 uint Read 0 65535

4732 2 11 5 uint Read 0 65535

4734 2 11 6 uint Read 0 65535

4736 2 11 7 uint Read 0 65535

4738 2 11 8 uint Read 0 65535

4740 2 12 1 uint Read 0 65535

4742 2 12 2 uint Read 0 65535

4744 2 12 3 uint Read 0 65535

Page 75: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

73

Register Length Preset Component Data Type Read/Write Min Value Max Value

4746 2 12 4 uint Read 0 65535

4748 2 12 5 uint Read 0 65535

4750 2 12 6 uint Read 0 65535

4752 2 12 7 uint Read 0 65535

4754 2 12 8 uint Read 0 65535

5.2.12 Component Batch Average Temp in Tenths or Hundredths

Register Length Preset Component Data Type Read/Write Min Value Max Value

4756 2 1 1 int Read -50.00 350.00

4758 2 1 2 int Read -50.00 350.00

4760 2 1 3 int Read -50.00 350.00

4762 2 1 4 int Read -50.00 350.00

4764 2 1 5 int Read -50.00 350.00

4766 2 1 6 int Read -50.00 350.00

4768 2 1 7 int Read -50.00 350.00

4770 2 1 8 int Read -50.00 350.00

4772 2 2 1 int Read -50.00 350.00

4774 2 2 2 int Read -50.00 350.00

4776 2 2 3 int Read -50.00 350.00

4778 2 2 4 int Read -50.00 350.00

4780 2 2 5 int Read -50.00 350.00

4782 2 2 6 int Read -50.00 350.00

4784 2 2 7 int Read -50.00 350.00

4786 2 2 8 int Read -50.00 350.00

4788 2 3 1 int Read -50.00 350.00

4790 2 3 2 int Read -50.00 350.00

4792 2 3 3 int Read -50.00 350.00

4794 2 3 4 int Read -50.00 350.00

4796 2 3 5 int Read -50.00 350.00

4798 2 3 6 int Read -50.00 350.00

4800 2 3 7 int Read -50.00 350.00

4802 2 3 8 int Read -50.00 350.00

4804 2 4 1 int Read -50.00 350.00

4806 2 4 2 int Read -50.00 350.00

4808 2 4 3 int Read -50.00 350.00

4810 2 4 4 int Read -50.00 350.00

4812 2 4 5 int Read -50.00 350.00

4814 2 4 6 int Read -50.00 350.00

4816 2 4 7 int Read -50.00 350.00

4818 2 4 8 int Read -50.00 350.00

Page 76: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

74

Register Length Preset Component Data Type Read/Write Min Value Max Value

4820 2 5 1 int Read -50.00 350.00

4822 2 5 2 int Read -50.00 350.00

4824 2 5 3 int Read -50.00 350.00

4826 2 5 4 int Read -50.00 350.00

4828 2 5 5 int Read -50.00 350.00

4830 2 5 6 int Read -50.00 350.00

4832 2 5 7 int Read -50.00 350.00

4834 2 5 8 int Read -50.00 350.00

4836 2 6 1 int Read -50.00 350.00

4838 2 6 2 int Read -50.00 350.00

4840 2 6 3 int Read -50.00 350.00

4842 2 6 4 int Read -50.00 350.00

4844 2 6 5 int Read -50.00 350.00

4846 2 6 6 int Read -50.00 350.00

4848 2 6 7 int Read -50.00 350.00

4850 2 6 8 int Read -50.00 350.00

4852 2 7 1 int Read -50.00 350.00

4854 2 7 2 int Read -50.00 350.00

4856 2 7 3 int Read -50.00 350.00

4858 2 7 4 int Read -50.00 350.00

4860 2 7 5 int Read -50.00 350.00

4862 2 7 6 int Read -50.00 350.00

4864 2 7 7 int Read -50.00 350.00

4866 2 7 8 int Read -50.00 350.00

4868 2 8 1 int Read -50.00 350.00

4870 2 8 2 int Read -50.00 350.00

4872 2 8 3 int Read -50.00 350.00

4874 2 8 4 int Read -50.00 350.00

4876 2 8 5 int Read -50.00 350.00

4878 2 8 6 int Read -50.00 350.00

4880 2 8 7 int Read -50.00 350.00

4882 2 8 8 int Read -50.00 350.00

4884 2 9 1 int Read -50.00 350.00

4886 2 9 2 int Read -50.00 350.00

4888 2 9 3 int Read -50.00 350.00

4890 2 9 4 int Read -50.00 350.00

4892 2 9 5 int Read -50.00 350.00

4894 2 9 6 int Read -50.00 350.00

4896 2 9 7 int Read -50.00 350.00

4898 2 9 8 int Read -50.00 350.00

4900 2 10 1 int Read -50.00 350.00

Page 77: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

75

Register Length Preset Component Data Type Read/Write Min Value Max Value

4902 2 10 2 int Read -50.00 350.00

4904 2 10 3 int Read -50.00 350.00

4906 2 10 4 int Read -50.00 350.00

4908 2 10 5 int Read -50.00 350.00

4910 2 10 6 int Read -50.00 350.00

4912 2 10 7 int Read -50.00 350.00

4914 2 10 8 int Read -50.00 350.00

4916 2 11 1 int Read -50.00 350.00

4918 2 11 2 int Read -50.00 350.00

4920 2 11 3 int Read -50.00 350.00

4922 2 11 4 int Read -50.00 350.00

4924 2 11 5 int Read -50.00 350.00

4926 2 11 6 int Read -50.00 350.00

4928 2 11 7 int Read -50.00 350.00

4930 2 11 8 int Read -50.00 350.00

4932 2 12 1 int Read -50.00 350.00

4934 2 12 2 int Read -50.00 350.00

4936 2 12 3 int Read -50.00 350.00

4938 2 12 4 int Read -50.00 350.00

4940 2 12 5 int Read -50.00 350.00

4942 2 12 6 int Read -50.00 350.00

4944 2 12 7 int Read -50.00 350.00

4946 2 12 8 int Read -50.00 350.00

5.2.13 Component Batch Average Pressure in Tenths or Hundredths

Register Length Preset Component Data Type Read/Write Min Value Max Value

4948 2 1 1 int Read -20.00 650.00

4950 2 1 2 int Read -20.00 650.00

4952 2 1 3 int Read -20.00 650.00

4954 2 1 4 int Read -20.00 650.00

4956 2 1 5 int Read -20.00 650.00

4958 2 1 6 int Read -20.00 650.00

4960 2 1 7 int Read -20.00 650.00

4962 2 1 8 int Read -20.00 650.00

4964 2 2 1 int Read -20.00 650.00

4966 2 2 2 int Read -20.00 650.00

4968 2 2 3 int Read -20.00 650.00

4970 2 2 4 int Read -20.00 650.00

4972 2 2 5 int Read -20.00 650.00

Page 78: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

76

Register Length Preset Component Data Type Read/Write Min Value Max Value

4974 2 2 6 int Read -20.00 650.00

4976 2 2 7 int Read -20.00 650.00

4978 2 2 8 int Read -20.00 650.00

4980 2 3 1 int Read -20.00 650.00

4982 2 3 2 int Read -20.00 650.00

4984 2 3 3 int Read -20.00 650.00

4986 2 3 4 int Read -20.00 650.00

4988 2 3 5 int Read -20.00 650.00

4990 2 3 6 int Read -20.00 650.00

4992 2 3 7 int Read -20.00 650.00

4994 2 3 8 int Read -20.00 650.00

4996 2 4 1 int Read -20.00 650.00

4998 2 4 2 int Read -20.00 650.00

5000 2 4 3 int Read -20.00 650.00

5002 2 4 4 int Read -20.00 650.00

5004 2 4 5 int Read -20.00 650.00

5006 2 4 6 int Read -20.00 650.00

5008 2 4 7 int Read -20.00 650.00

5010 2 4 8 int Read -20.00 650.00

5012 2 5 1 int Read -20.00 650.00

5014 2 5 2 int Read -20.00 650.00

5016 2 5 3 int Read -20.00 650.00

5018 2 5 4 int Read -20.00 650.00

5020 2 5 5 int Read -20.00 650.00

5022 2 5 6 int Read -20.00 650.00

5024 2 5 7 int Read -20.00 650.00

5026 2 5 8 int Read -20.00 650.00

5028 2 6 1 int Read -20.00 650.00

5030 2 6 2 int Read -20.00 650.00

5032 2 6 3 int Read -20.00 650.00

5034 2 6 4 int Read -20.00 650.00

5036 2 6 5 int Read -20.00 650.00

5038 2 6 6 int Read -20.00 650.00

5040 2 6 7 int Read -20.00 650.00

5042 2 6 8 int Read -20.00 650.00

5044 2 7 1 int Read -20.00 650.00

5046 2 7 2 int Read -20.00 650.00

5048 2 7 3 int Read -20.00 650.00

5050 2 7 4 int Read -20.00 650.00

5052 2 7 5 int Read -20.00 650.00

5054 2 7 6 int Read -20.00 650.00

Page 79: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

77

Register Length Preset Component Data Type Read/Write Min Value Max Value

5056 2 7 7 int Read -20.00 650.00

5058 2 7 8 int Read -20.00 650.00

5060 2 8 1 int Read -20.00 650.00

5062 2 8 2 int Read -20.00 650.00

5064 2 8 3 int Read -20.00 650.00

5066 2 8 4 int Read -20.00 650.00

5068 2 8 5 int Read -20.00 650.00

5070 2 8 6 int Read -20.00 650.00

5072 2 8 7 int Read -20.00 650.00

5074 2 8 8 int Read -20.00 650.00

5076 2 9 1 int Read -20.00 650.00

5078 2 9 2 int Read -20.00 650.00

5080 2 9 3 int Read -20.00 650.00

5082 2 9 4 int Read -20.00 650.00

5084 2 9 5 int Read -20.00 650.00

5086 2 9 6 int Read -20.00 650.00

5088 2 9 7 int Read -20.00 650.00

5090 2 9 8 int Read -20.00 650.00

5092 2 10 1 int Read -20.00 650.00

5094 2 10 2 int Read -20.00 650.00

5096 2 10 3 int Read -20.00 650.00

5098 2 10 4 int Read -20.00 650.00

5100 2 10 5 int Read -20.00 650.00

5102 2 10 6 int Read -20.00 650.00

5104 2 10 7 int Read -20.00 650.00

5106 2 10 8 int Read -20.00 650.00

5108 2 11 1 int Read -20.00 650.00

5110 2 11 2 int Read -20.00 650.00

5112 2 11 3 int Read -20.00 650.00

5114 2 11 4 int Read -20.00 650.00

5116 2 11 5 int Read -20.00 650.00

5118 2 11 6 int Read -20.00 650.00

5120 2 11 7 int Read -20.00 650.00

5122 2 11 8 int Read -20.00 650.00

5124 2 12 1 int Read -20.00 650.00

5126 2 12 2 int Read -20.00 650.00

5128 2 12 3 int Read -20.00 650.00

5130 2 12 4 int Read -20.00 650.00

5132 2 12 5 int Read -20.00 650.00

5134 2 12 6 int Read -20.00 650.00

5136 2 12 7 int Read -20.00 650.00

Page 80: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

78

Register Length Preset Component Data Type Read/Write Min Value Max Value

5138 2 12 8 int Read -20.00 650.00

5.2.14 Component Batch Average Density/Relative Density/Gravity

Register Length Preset Component Data Type Read/Write Min Value Max Value

5140 2 1 1 int Read -100.00 1200.00

5142 2 1 2 int Read -100.00 1200.00

5144 2 1 3 int Read -100.00 1200.00

5146 2 1 4 int Read -100.00 1200.00

5148 2 1 5 int Read -100.00 1200.00

5150 2 1 6 int Read -100.00 1200.00

5152 2 1 7 int Read -100.00 1200.00

5154 2 1 8 int Read -100.00 1200.00

5156 2 2 1 int Read -100.00 1200.00

5158 2 2 2 int Read -100.00 1200.00

5160 2 2 3 int Read -100.00 1200.00

5162 2 2 4 int Read -100.00 1200.00

5164 2 2 5 int Read -100.00 1200.00

5166 2 2 6 int Read -100.00 1200.00

5168 2 2 7 int Read -100.00 1200.00

5170 2 2 8 int Read -100.00 1200.00

5172 2 3 1 int Read -100.00 1200.00

5174 2 3 2 int Read -100.00 1200.00

5176 2 3 3 int Read -100.00 1200.00

5178 2 3 4 int Read -100.00 1200.00

5180 2 3 5 int Read -100.00 1200.00

5182 2 3 6 int Read -100.00 1200.00

5184 2 3 7 int Read -100.00 1200.00

5186 2 3 8 int Read -100.00 1200.00

5188 2 4 1 int Read -100.00 1200.00

5190 2 4 2 int Read -100.00 1200.00

5192 2 4 3 int Read -100.00 1200.00

5194 2 4 4 int Read -100.00 1200.00

5196 2 4 5 int Read -100.00 1200.00

5198 2 4 6 int Read -100.00 1200.00

5200 2 4 7 int Read -100.00 1200.00

5202 2 4 8 int Read -100.00 1200.00

5204 2 5 1 int Read -100.00 1200.00

5206 2 5 2 int Read -100.00 1200.00

5208 2 5 3 int Read -100.00 1200.00

5210 2 5 4 int Read -100.00 1200.00

5212 2 5 5 int Read -100.00 1200.00

Page 81: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

79

Register Length Preset Component Data Type Read/Write Min Value Max Value

5214 2 5 6 int Read -100.00 1200.00

5216 2 5 7 int Read -100.00 1200.00

5218 2 5 8 int Read -100.00 1200.00

5220 2 6 1 int Read -100.00 1200.00

5222 2 6 2 int Read -100.00 1200.00

5224 2 6 3 int Read -100.00 1200.00

5226 2 6 4 int Read -100.00 1200.00

5228 2 6 5 int Read -100.00 1200.00

5230 2 6 6 int Read -100.00 1200.00

5232 2 6 7 int Read -100.00 1200.00

5234 2 6 8 int Read -100.00 1200.00

5236 2 7 1 int Read -100.00 1200.00

5238 2 7 2 int Read -100.00 1200.00

5240 2 7 3 int Read -100.00 1200.00

5242 2 7 4 int Read -100.00 1200.00

5244 2 7 5 int Read -100.00 1200.00

5246 2 7 6 int Read -100.00 1200.00

5248 2 7 7 int Read -100.00 1200.00

5250 2 7 8 int Read -100.00 1200.00

5252 2 8 1 int Read -100.00 1200.00

5254 2 8 2 int Read -100.00 1200.00

5256 2 8 3 int Read -100.00 1200.00

5258 2 8 4 int Read -100.00 1200.00

5260 2 8 5 int Read -100.00 1200.00

5262 2 8 6 int Read -100.00 1200.00

5264 2 8 7 int Read -100.00 1200.00

5266 2 8 8 int Read -100.00 1200.00

5268 2 9 1 int Read -100.00 1200.00

5270 2 9 2 int Read -100.00 1200.00

5272 2 9 3 int Read -100.00 1200.00

5274 2 9 4 int Read -100.00 1200.00

5276 2 9 5 int Read -100.00 1200.00

5278 2 9 6 int Read -100.00 1200.00

5280 2 9 7 int Read -100.00 1200.00

5282 2 9 8 int Read -100.00 1200.00

5284 2 10 1 int Read -100.00 1200.00

5286 2 10 2 int Read -100.00 1200.00

5288 2 10 3 int Read -100.00 1200.00

5290 2 10 4 int Read -100.00 1200.00

5292 2 10 5 int Read -100.00 1200.00

5294 2 10 6 int Read -100.00 1200.00

Page 82: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

80

Register Length Preset Component Data Type Read/Write Min Value Max Value

5296 2 10 7 int Read -100.00 1200.00

5298 2 10 8 int Read -100.00 1200.00

5300 2 11 1 int Read -100.00 1200.00

5302 2 11 2 int Read -100.00 1200.00

5304 2 11 3 int Read -100.00 1200.00

5306 2 11 4 int Read -100.00 1200.00

5308 2 11 5 int Read -100.00 1200.00

5310 2 11 6 int Read -100.00 1200.00

5312 2 11 7 int Read -100.00 1200.00

5314 2 11 8 int Read -100.00 1200.00

5316 2 12 1 int Read -100.00 1200.00

5318 2 12 2 int Read -100.00 1200.00

5320 2 12 3 int Read -100.00 1200.00

5322 2 12 4 int Read -100.00 1200.00

5324 2 12 5 int Read -100.00 1200.00

5326 2 12 6 int Read -100.00 1200.00

5328 2 12 7 int Read -100.00 1200.00

5330 2 12 8 int Read -100.00 1200.00

5.2.15 Component Current Temp in Hundredths

Register Length Preset Component Data Type Read/Write Min Value Max Value

5332 2 1 1 int Read -50.00 350.00

5334 2 1 2 int Read -50.00 350.00

5336 2 1 3 int Read -50.00 350.00

5338 2 1 4 int Read -50.00 350.00

5340 2 1 5 int Read -50.00 350.00

5342 2 1 6 int Read -50.00 350.00

5344 2 1 7 int Read -50.00 350.00

5346 2 1 8 int Read -50.00 350.00

5348 2 2 1 int Read -50.00 350.00

5350 2 2 2 int Read -50.00 350.00

5352 2 2 3 int Read -50.00 350.00

5354 2 2 4 int Read -50.00 350.00

5356 2 2 5 int Read -50.00 350.00

5358 2 2 6 int Read -50.00 350.00

5360 2 2 7 int Read -50.00 350.00

5362 2 2 8 int Read -50.00 350.00

5364 2 3 1 int Read -50.00 350.00

5366 2 3 2 int Read -50.00 350.00

Page 83: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

81

Register Length Preset Component Data Type Read/Write Min Value Max Value

5368 2 3 3 int Read -50.00 350.00

5370 2 3 4 int Read -50.00 350.00

5372 2 3 5 int Read -50.00 350.00

5374 2 3 6 int Read -50.00 350.00

5376 2 3 7 int Read -50.00 350.00

5378 2 3 8 int Read -50.00 350.00

5380 2 4 1 int Read -50.00 350.00

5382 2 4 2 int Read -50.00 350.00

5384 2 4 3 int Read -50.00 350.00

5386 2 4 4 int Read -50.00 350.00

5388 2 4 5 int Read -50.00 350.00

5390 2 4 6 int Read -50.00 350.00

5392 2 4 7 int Read -50.00 350.00

5394 2 4 8 int Read -50.00 350.00

5396 2 5 1 int Read -50.00 350.00

5398 2 5 2 int Read -50.00 350.00

5400 2 5 3 int Read -50.00 350.00

5402 2 5 4 int Read -50.00 350.00

5404 2 5 5 int Read -50.00 350.00

5406 2 5 6 int Read -50.00 350.00

5408 2 5 7 int Read -50.00 350.00

5410 2 5 8 int Read -50.00 350.00

5412 2 6 1 int Read -50.00 350.00

5414 2 6 2 int Read -50.00 350.00

5416 2 6 3 int Read -50.00 350.00

5418 2 6 4 int Read -50.00 350.00

5420 2 6 5 int Read -50.00 350.00

5422 2 6 6 int Read -50.00 350.00

5424 2 6 7 int Read -50.00 350.00

5426 2 6 8 int Read -50.00 350.00

5428 2 7 1 int Read -50.00 350.00

5430 2 7 2 int Read -50.00 350.00

5432 2 7 3 int Read -50.00 350.00

5434 2 7 4 int Read -50.00 350.00

5436 2 7 5 int Read -50.00 350.00

5438 2 7 6 int Read -50.00 350.00

5440 2 7 7 int Read -50.00 350.00

5442 2 7 8 int Read -50.00 350.00

5444 2 8 1 int Read -50.00 350.00

5446 2 8 2 int Read -50.00 350.00

5448 2 8 3 int Read -50.00 350.00

Page 84: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

82

Register Length Preset Component Data Type Read/Write Min Value Max Value

5450 2 8 4 int Read -50.00 350.00

5452 2 8 5 int Read -50.00 350.00

5454 2 8 6 int Read -50.00 350.00

5456 2 8 7 int Read -50.00 350.00

5458 2 8 8 int Read -50.00 350.00

5460 2 9 1 int Read -50.00 350.00

5462 2 9 2 int Read -50.00 350.00

5464 2 9 3 int Read -50.00 350.00

5466 2 9 4 int Read -50.00 350.00

5468 2 9 5 int Read -50.00 350.00

5470 2 9 6 int Read -50.00 350.00

5472 2 9 7 int Read -50.00 350.00

5474 2 9 8 int Read -50.00 350.00

5476 2 10 1 int Read -50.00 350.00

5478 2 10 2 int Read -50.00 350.00

5480 2 10 3 int Read -50.00 350.00

5482 2 10 4 int Read -50.00 350.00

5484 2 10 5 int Read -50.00 350.00

5486 2 10 6 int Read -50.00 350.00

5488 2 10 7 int Read -50.00 350.00

5490 2 10 8 int Read -50.00 350.00

5492 2 11 1 int Read -50.00 350.00

5494 2 11 2 int Read -50.00 350.00

5496 2 11 3 int Read -50.00 350.00

5498 2 11 4 int Read -50.00 350.00

5500 2 11 5 int Read -50.00 350.00

5502 2 11 6 int Read -50.00 350.00

5504 2 11 7 int Read -50.00 350.00

5506 2 11 8 int Read -50.00 350.00

5508 2 12 1 int Read -50.00 350.00

5510 2 12 2 int Read -50.00 350.00

5512 2 12 3 int Read -50.00 350.00

5514 2 12 4 int Read -50.00 350.00

5516 2 12 5 int Read -50.00 350.00

5518 2 12 6 int Read -50.00 350.00

5520 2 12 7 int Read -50.00 350.00

5522 2 12 8 int Read -50.00 350.00

Page 85: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

83

5.2.16 Component Current Pressure in Hundredths

Register Length Preset Component Data Type Read/Write Min Value Max Value

5524 2 1 1 int Read -20.00 650.00

5526 2 1 2 int Read -20.00 650.00

5528 2 1 3 int Read -20.00 650.00

5530 2 1 4 int Read -20.00 650.00

5532 2 1 5 int Read -20.00 650.00

5534 2 1 6 int Read -20.00 650.00

5536 2 1 7 int Read -20.00 650.00

5538 2 1 8 int Read -20.00 650.00

5540 2 2 1 int Read -20.00 650.00

5542 2 2 2 int Read -20.00 650.00

5544 2 2 3 int Read -20.00 650.00

5546 2 2 4 int Read -20.00 650.00

5548 2 2 5 int Read -20.00 650.00

5550 2 2 6 int Read -20.00 650.00

5552 2 2 7 int Read -20.00 650.00

5554 2 2 8 int Read -20.00 650.00

5556 2 3 1 int Read -20.00 650.00

5558 2 3 2 int Read -20.00 650.00

5560 2 3 3 int Read -20.00 650.00

5562 2 3 4 int Read -20.00 650.00

5564 2 3 5 int Read -20.00 650.00

5566 2 3 6 int Read -20.00 650.00

5568 2 3 7 int Read -20.00 650.00

5570 2 3 8 int Read -20.00 650.00

5572 2 4 1 int Read -20.00 650.00

5574 2 4 2 int Read -20.00 650.00

5576 2 4 3 int Read -20.00 650.00

5578 2 4 4 int Read -20.00 650.00

5580 2 4 5 int Read -20.00 650.00

5582 2 4 6 int Read -20.00 650.00

5584 2 4 7 int Read -20.00 650.00

5586 2 4 8 int Read -20.00 650.00

5588 2 5 1 int Read -20.00 650.00

5590 2 5 2 int Read -20.00 650.00

5592 2 5 3 int Read -20.00 650.00

5594 2 5 4 int Read -20.00 650.00

5596 2 5 5 int Read -20.00 650.00

5598 2 5 6 int Read -20.00 650.00

5600 2 5 7 int Read -20.00 650.00

Page 86: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

84

Register Length Preset Component Data Type Read/Write Min Value Max Value

5602 2 5 8 int Read -20.00 650.00

5604 2 6 1 int Read -20.00 650.00

5606 2 6 2 int Read -20.00 650.00

5608 2 6 3 int Read -20.00 650.00

5610 2 6 4 int Read -20.00 650.00

5612 2 6 5 int Read -20.00 650.00

5614 2 6 6 int Read -20.00 650.00

5616 2 6 7 int Read -20.00 650.00

5618 2 6 8 int Read -20.00 650.00

5620 2 7 1 int Read -20.00 650.00

5622 2 7 2 int Read -20.00 650.00

5624 2 7 3 int Read -20.00 650.00

5626 2 7 4 int Read -20.00 650.00

5628 2 7 5 int Read -20.00 650.00

5630 2 7 6 int Read -20.00 650.00

5632 2 7 7 int Read -20.00 650.00

5634 2 7 8 int Read -20.00 650.00

5636 2 8 1 int Read -20.00 650.00

5638 2 8 2 int Read -20.00 650.00

5640 2 8 3 int Read -20.00 650.00

5642 2 8 4 int Read -20.00 650.00

5644 2 8 5 int Read -20.00 650.00

5646 2 8 6 int Read -20.00 650.00

5648 2 8 7 int Read -20.00 650.00

5650 2 8 8 int Read -20.00 650.00

5652 2 9 1 int Read -20.00 650.00

5654 2 9 2 int Read -20.00 650.00

5656 2 9 3 int Read -20.00 650.00

5658 2 9 4 int Read -20.00 650.00

5660 2 9 5 int Read -20.00 650.00

5662 2 9 6 int Read -20.00 650.00

5664 2 9 7 int Read -20.00 650.00

5666 2 9 8 int Read -20.00 650.00

5668 2 10 1 int Read -20.00 650.00

5670 2 10 2 int Read -20.00 650.00

5672 2 10 3 int Read -20.00 650.00

5674 2 10 4 int Read -20.00 650.00

5676 2 10 5 int Read -20.00 650.00

5678 2 10 6 int Read -20.00 650.00

5680 2 10 7 int Read -20.00 650.00

5682 2 10 8 int Read -20.00 650.00

Page 87: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

85

Register Length Preset Component Data Type Read/Write Min Value Max Value

5684 2 11 1 int Read -20.00 650.00

5686 2 11 2 int Read -20.00 650.00

5688 2 11 3 int Read -20.00 650.00

5690 2 11 4 int Read -20.00 650.00

5692 2 11 5 int Read -20.00 650.00

5694 2 11 6 int Read -20.00 650.00

5696 2 11 7 int Read -20.00 650.00

5698 2 11 8 int Read -20.00 650.00

5700 2 12 1 int Read -20.00 650.00

5702 2 12 2 int Read -20.00 650.00

5704 2 12 3 int Read -20.00 650.00

5706 2 12 4 int Read -20.00 650.00

5708 2 12 5 int Read -20.00 650.00

5710 2 12 6 int Read -20.00 650.00

5712 2 12 7 int Read -20.00 650.00

5714 2 12 8 int Read -20.00 650.00

5.2.17 Component Current Density in Tenths

Register Length Preset Component Data Type Read/Write Min Value Max Value

5716 2 1 1 uint Read 0 1200.00

5718 2 1 2 uint Read 0 1200.00

5720 2 1 3 uint Read 0 1200.00

5722 2 1 4 uint Read 0 1200.00

5724 2 1 5 uint Read 0 1200.00

5726 2 1 6 uint Read 0 1200.00

5728 2 1 7 uint Read 0 1200.00

5730 2 1 8 uint Read 0 1200.00

5732 2 2 1 uint Read 0 1200.00

5734 2 2 2 uint Read 0 1200.00

5736 2 2 3 uint Read 0 1200.00

5738 2 2 4 uint Read 0 1200.00

5740 2 2 5 uint Read 0 1200.00

5742 2 2 6 uint Read 0 1200.00

5744 2 2 7 uint Read 0 1200.00

5746 2 2 8 uint Read 0 1200.00

5748 2 3 1 uint Read 0 1200.00

5750 2 3 2 uint Read 0 1200.00

5752 2 3 3 uint Read 0 1200.00

5754 2 3 4 uint Read 0 1200.00

Page 88: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

86

Register Length Preset Component Data Type Read/Write Min Value Max Value

5756 2 3 5 uint Read 0 1200.00

5758 2 3 6 uint Read 0 1200.00

5760 2 3 7 uint Read 0 1200.00

5762 2 3 8 uint Read 0 1200.00

5764 2 4 1 uint Read 0 1200.00

5766 2 4 2 uint Read 0 1200.00

5768 2 4 3 uint Read 0 1200.00

5770 2 4 4 uint Read 0 1200.00

5772 2 4 5 uint Read 0 1200.00

5774 2 4 6 uint Read 0 1200.00

5776 2 4 7 uint Read 0 1200.00

5778 2 4 8 uint Read 0 1200.00

5780 2 5 1 uint Read 0 1200.00

5782 2 5 2 uint Read 0 1200.00

5784 2 5 3 uint Read 0 1200.00

5786 2 5 4 uint Read 0 1200.00

5788 2 5 5 uint Read 0 1200.00

5790 2 5 6 uint Read 0 1200.00

5792 2 5 7 uint Read 0 1200.00

5794 2 5 8 uint Read 0 1200.00

5796 2 6 1 uint Read 0 1200.00

5798 2 6 2 uint Read 0 1200.00

5800 2 6 3 uint Read 0 1200.00

5802 2 6 4 uint Read 0 1200.00

5804 2 6 5 uint Read 0 1200.00

5806 2 6 6 uint Read 0 1200.00

5808 2 6 7 uint Read 0 1200.00

5810 2 6 8 uint Read 0 1200.00

5812 2 7 1 uint Read 0 1200.00

5814 2 7 2 uint Read 0 1200.00

5816 2 7 3 uint Read 0 1200.00

5818 2 7 4 uint Read 0 1200.00

5820 2 7 5 uint Read 0 1200.00

5822 2 7 6 uint Read 0 1200.00

5824 2 7 7 uint Read 0 1200.00

5826 2 7 8 uint Read 0 1200.00

5828 2 8 1 uint Read 0 1200.00

5830 2 8 2 uint Read 0 1200.00

5832 2 8 3 uint Read 0 1200.00

5834 2 8 4 uint Read 0 1200.00

5836 2 8 5 uint Read 0 1200.00

Page 89: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

87

Register Length Preset Component Data Type Read/Write Min Value Max Value

5838 2 8 6 uint Read 0 1200.00

5840 2 8 7 uint Read 0 1200.00

5842 2 8 8 uint Read 0 1200.00

5844 2 9 1 uint Read 0 1200.00

5846 2 9 2 uint Read 0 1200.00

5848 2 9 3 uint Read 0 1200.00

5850 2 9 4 uint Read 0 1200.00

5852 2 9 5 uint Read 0 1200.00

5854 2 9 6 uint Read 0 1200.00

5856 2 9 7 uint Read 0 1200.00

5858 2 9 8 uint Read 0 1200.00

5860 2 10 1 uint Read 0 1200.00

5862 2 10 2 uint Read 0 1200.00

5864 2 10 3 uint Read 0 1200.00

5866 2 10 4 uint Read 0 1200.00

5868 2 10 5 uint Read 0 1200.00

5870 2 10 6 uint Read 0 1200.00

5872 2 10 7 uint Read 0 1200.00

5874 2 10 8 uint Read 0 1200.00

5876 2 11 1 uint Read 0 1200.00

5878 2 11 2 uint Read 0 1200.00

5880 2 11 3 uint Read 0 1200.00

5882 2 11 4 uint Read 0 1200.00

5884 2 11 5 uint Read 0 1200.00

5886 2 11 6 uint Read 0 1200.00

5888 2 11 7 uint Read 0 1200.00

5890 2 11 8 uint Read 0 1200.00

5892 2 12 1 uint Read 0 1200.00

5894 2 12 2 uint Read 0 1200.00

5896 2 12 3 uint Read 0 1200.00

5898 2 12 4 uint Read 0 1200.00

5900 2 12 5 uint Read 0 1200.00

5902 2 12 6 uint Read 0 1200.00

5904 2 12 7 uint Read 0 1200.00

5906 2 12 8 uint Read 0 1200.00

5.2.18 Additive Delivered Quantity in Thousands

Register Length Preset Additive Data Type Read/Write Min Value Max Value

5908 2 1 1 uint Read 0 65535

Page 90: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

88

Register Length Preset Additive Data Type Read/Write Min Value Max Value

5910 2 1 2 uint Read 0 65535

5912 2 1 3 uint Read 0 65535

5914 2 1 4 uint Read 0 65535

5916 2 1 5 uint Read 0 65535

5918 2 1 6 uint Read 0 65535

5920 2 1 7 uint Read 0 65535

5922 2 1 8 uint Read 0 65535

5924 2 1 9 uint Read 0 65535

5926 2 1 10 uint Read 0 65535

5928 2 1 11 uint Read 0 65535

5930 2 1 12 uint Read 0 65535

5932 2 1 13 uint Read 0 65535

5934 2 1 14 uint Read 0 65535

5936 2 1 15 uint Read 0 65535

5938 2 1 16 uint Read 0 65535

5940 2 2 1 uint Read 0 65535

5942 2 2 2 uint Read 0 65535

5944 2 2 3 uint Read 0 65535

5946 2 2 4 uint Read 0 65535

5948 2 2 5 uint Read 0 65535

5950 2 2 6 uint Read 0 65535

5952 2 2 7 uint Read 0 65535

5954 2 2 8 uint Read 0 65535

5956 2 2 9 uint Read 0 65535

5958 2 2 10 uint Read 0 65535

5960 2 2 11 uint Read 0 65535

5962 2 2 12 uint Read 0 65535

5964 2 2 13 uint Read 0 65535

5966 2 2 14 uint Read 0 65535

5968 2 2 15 uint Read 0 65535

5970 2 2 16 uint Read 0 65535

5972 2 3 1 uint Read 0 65535

5974 2 3 2 uint Read 0 65535

5976 2 3 3 uint Read 0 65535

5978 2 3 4 uint Read 0 65535

5980 2 3 5 uint Read 0 65535

5982 2 3 6 uint Read 0 65535

5984 2 3 7 uint Read 0 65535

5986 2 3 8 uint Read 0 65535

5988 2 3 9 uint Read 0 65535

5990 2 3 10 uint Read 0 65535

Page 91: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

89

Register Length Preset Additive Data Type Read/Write Min Value Max Value

5992 2 3 11 uint Read 0 65535

5994 2 3 12 uint Read 0 65535

5996 2 3 13 uint Read 0 65535

5998 2 3 14 uint Read 0 65535

6000 2 3 15 uint Read 0 65535

6002 2 3 16 uint Read 0 65535

6004 2 4 1 uint Read 0 65535

6006 2 4 2 uint Read 0 65535

6008 2 4 3 uint Read 0 65535

6010 2 4 4 uint Read 0 65535

6012 2 4 5 uint Read 0 65535

6014 2 4 6 uint Read 0 65535

6016 2 4 7 uint Read 0 65535

6018 2 4 8 uint Read 0 65535

6020 2 4 9 uint Read 0 65535

6022 2 4 10 uint Read 0 65535

6024 2 4 11 uint Read 0 65535

6026 2 4 12 uint Read 0 65535

6028 2 4 13 uint Read 0 65535

6030 2 4 14 uint Read 0 65535

6032 2 4 15 uint Read 0 65535

6034 2 4 16 uint Read 0 65535

6036 2 5 1 uint Read 0 65535

6038 2 5 2 uint Read 0 65535

6040 2 5 3 uint Read 0 65535

6042 2 5 4 uint Read 0 65535

6044 2 5 5 uint Read 0 65535

6046 2 5 6 uint Read 0 65535

6048 2 5 7 uint Read 0 65535

6050 2 5 8 uint Read 0 65535

6052 2 5 9 uint Read 0 65535

6054 2 5 10 uint Read 0 65535

6056 2 5 11 uint Read 0 65535

6058 2 5 12 uint Read 0 65535

6060 2 5 13 uint Read 0 65535

6062 2 5 14 uint Read 0 65535

6064 2 5 15 uint Read 0 65535

6066 2 5 16 uint Read 0 65535

6068 2 6 1 uint Read 0 65535

6070 2 6 2 uint Read 0 65535

6072 2 6 3 uint Read 0 65535

Page 92: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

90

Register Length Preset Additive Data Type Read/Write Min Value Max Value

6074 2 6 4 uint Read 0 65535

6076 2 6 5 uint Read 0 65535

6078 2 6 6 uint Read 0 65535

6080 2 6 7 uint Read 0 65535

6082 2 6 8 uint Read 0 65535

6084 2 6 9 uint Read 0 65535

6086 2 6 10 uint Read 0 65535

6088 2 6 11 uint Read 0 65535

6090 2 6 12 uint Read 0 65535

6092 2 6 13 uint Read 0 65535

6094 2 6 14 uint Read 0 65535

6096 2 6 15 uint Read 0 65535

6098 2 6 16 uint Read 0 65535

6100 2 7 1 uint Read 0 65535

6102 2 7 2 uint Read 0 65535

6104 2 7 3 uint Read 0 65535

6106 2 7 4 uint Read 0 65535

6108 2 7 5 uint Read 0 65535

6110 2 7 6 uint Read 0 65535

6112 2 7 7 uint Read 0 65535

6114 2 7 8 uint Read 0 65535

6116 2 7 9 uint Read 0 65535

6118 2 7 10 uint Read 0 65535

6120 2 7 11 uint Read 0 65535

6122 2 7 12 uint Read 0 65535

6124 2 7 13 uint Read 0 65535

6126 2 7 14 uint Read 0 65535

6128 2 7 15 uint Read 0 65535

6130 2 7 16 uint Read 0 65535

6132 2 8 1 uint Read 0 65535

6134 2 8 2 uint Read 0 65535

6136 2 8 3 uint Read 0 65535

6138 2 8 4 uint Read 0 65535

6140 2 8 5 uint Read 0 65535

6142 2 8 6 uint Read 0 65535

6144 2 8 7 uint Read 0 65535

6146 2 8 8 uint Read 0 65535

6148 2 8 9 uint Read 0 65535

6150 2 8 10 uint Read 0 65535

6152 2 8 11 uint Read 0 65535

6154 2 8 12 uint Read 0 65535

Page 93: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

91

Register Length Preset Additive Data Type Read/Write Min Value Max Value

6156 2 8 13 uint Read 0 65535

6158 2 8 14 uint Read 0 65535

6160 2 8 15 uint Read 0 65535

6162 2 8 16 uint Read 0 65535

6164 2 9 1 uint Read 0 65535

6166 2 9 2 uint Read 0 65535

6168 2 9 3 uint Read 0 65535

6170 2 9 4 uint Read 0 65535

6172 2 9 5 uint Read 0 65535

6174 2 9 6 uint Read 0 65535

6176 2 9 7 uint Read 0 65535

6178 2 9 8 uint Read 0 65535

6180 2 9 9 uint Read 0 65535

6182 2 9 10 uint Read 0 65535

6184 2 9 11 uint Read 0 65535

6186 2 9 12 uint Read 0 65535

6188 2 9 13 uint Read 0 65535

6190 2 9 14 uint Read 0 65535

6192 2 9 15 uint Read 0 65535

6194 2 9 16 uint Read 0 65535

6196 2 10 1 uint Read 0 65535

6198 2 10 2 uint Read 0 65535

6200 2 10 3 uint Read 0 65535

6202 2 10 4 uint Read 0 65535

6204 2 10 5 uint Read 0 65535

6206 2 10 6 uint Read 0 65535

6208 2 10 7 uint Read 0 65535

6210 2 10 8 uint Read 0 65535

6212 2 10 9 uint Read 0 65535

6214 2 10 10 uint Read 0 65535

6216 2 10 11 uint Read 0 65535

6218 2 10 12 uint Read 0 65535

6220 2 10 13 uint Read 0 65535

6222 2 10 14 uint Read 0 65535

6224 2 10 15 uint Read 0 65535

6226 2 10 16 uint Read 0 65535

6228 2 11 1 uint Read 0 65535

6230 2 11 2 uint Read 0 65535

6232 2 11 3 uint Read 0 65535

6234 2 11 4 uint Read 0 65535

6236 2 11 5 uint Read 0 65535

Page 94: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

92

Register Length Preset Additive Data Type Read/Write Min Value Max Value

6238 2 11 6 uint Read 0 65535

6240 2 11 7 uint Read 0 65535

6242 2 11 8 uint Read 0 65535

6244 2 11 9 uint Read 0 65535

6246 2 11 10 uint Read 0 65535

6248 2 11 11 uint Read 0 65535

6250 2 11 12 uint Read 0 65535

6252 2 11 13 uint Read 0 65535

6254 2 11 14 uint Read 0 65535

6256 2 11 15 uint Read 0 65535

6258 2 11 16 uint Read 0 65535

6260 2 12 1 uint Read 0 65535

6262 2 12 2 uint Read 0 65535

6264 2 12 3 uint Read 0 65535

6266 2 12 4 uint Read 0 65535

6268 2 12 5 uint Read 0 65535

6270 2 12 6 uint Read 0 65535

6272 2 12 7 uint Read 0 65535

6274 2 12 8 uint Read 0 65535

6276 2 12 9 uint Read 0 65535

6278 2 12 10 uint Read 0 65535

6280 2 12 11 uint Read 0 65535

6282 2 12 12 uint Read 0 65535

6284 2 12 13 uint Read 0 65535

6286 2 12 14 uint Read 0 65535

6288 2 12 15 uint Read 0 65535

6290 2 12 16 uint Read 0 65535

5.2.19 Component Current Relative Density in Ten Thousands

Register Length Preset Component Data Type Read/Write Min Value Max Value

6292 2 1 1 uint Read 0 4.0000

6294 2 1 2 uint Read 0 4.0000

6296 2 1 3 uint Read 0 4.0000

6298 2 1 4 uint Read 0 4.0000

6300 2 1 5 uint Read 0 4.0000

6302 2 1 6 uint Read 0 4.0000

6304 2 1 7 uint Read 0 4.0000

6306 2 1 8 uint Read 0 4.0000

6308 2 2 1 uint Read 0 4.0000

Page 95: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

93

Register Length Preset Component Data Type Read/Write Min Value Max Value

6310 2 2 2 uint Read 0 4.0000

6312 2 2 3 uint Read 0 4.0000

6314 2 2 4 uint Read 0 4.0000

6316 2 2 5 uint Read 0 4.0000

6318 2 2 6 uint Read 0 4.0000

6320 2 2 7 uint Read 0 4.0000

6322 2 2 8 uint Read 0 4.0000

6324 2 3 1 uint Read 0 4.0000

6326 2 3 2 uint Read 0 4.0000

6328 2 3 3 uint Read 0 4.0000

6330 2 3 4 uint Read 0 4.0000

6332 2 3 5 uint Read 0 4.0000

6334 2 3 6 uint Read 0 4.0000

6336 2 3 7 uint Read 0 4.0000

6338 2 3 8 uint Read 0 4.0000

6340 2 4 1 uint Read 0 4.0000

6342 2 4 2 uint Read 0 4.0000

6344 2 4 3 uint Read 0 4.0000

6346 2 4 4 uint Read 0 4.0000

6348 2 4 5 uint Read 0 4.0000

6350 2 4 6 uint Read 0 4.0000

6352 2 4 7 uint Read 0 4.0000

6354 2 4 8 uint Read 0 4.0000

6356 2 5 1 uint Read 0 4.0000

6358 2 5 2 uint Read 0 4.0000

6360 2 5 3 uint Read 0 4.0000

6362 2 5 4 uint Read 0 4.0000

6364 2 5 5 uint Read 0 4.0000

6366 2 5 6 uint Read 0 4.0000

6368 2 5 7 uint Read 0 4.0000

6370 2 5 8 uint Read 0 4.0000

6372 2 6 1 uint Read 0 4.0000

6374 2 6 2 uint Read 0 4.0000

6376 2 6 3 uint Read 0 4.0000

6378 2 6 4 uint Read 0 4.0000

6380 2 6 5 uint Read 0 4.0000

6382 2 6 6 uint Read 0 4.0000

6384 2 6 7 uint Read 0 4.0000

6386 2 6 8 uint Read 0 4.0000

6388 2 7 1 uint Read 0 4.0000

6390 2 7 2 uint Read 0 4.0000

Page 96: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

94

Register Length Preset Component Data Type Read/Write Min Value Max Value

6392 2 7 3 uint Read 0 4.0000

6394 2 7 4 uint Read 0 4.0000

6396 2 7 5 uint Read 0 4.0000

6398 2 7 6 uint Read 0 4.0000

6400 2 7 7 uint Read 0 4.0000

6402 2 7 8 uint Read 0 4.0000

6404 2 8 1 uint Read 0 4.0000

6406 2 8 2 uint Read 0 4.0000

6408 2 8 3 uint Read 0 4.0000

6410 2 8 4 uint Read 0 4.0000

6412 2 8 5 uint Read 0 4.0000

6414 2 8 6 uint Read 0 4.0000

6416 2 8 7 uint Read 0 4.0000

6418 2 8 8 uint Read 0 4.0000

6420 2 9 1 uint Read 0 4.0000

6422 2 9 2 uint Read 0 4.0000

6424 2 9 3 uint Read 0 4.0000

6426 2 9 4 uint Read 0 4.0000

6428 2 9 5 uint Read 0 4.0000

6430 2 9 6 uint Read 0 4.0000

6432 2 9 7 uint Read 0 4.0000

6434 2 9 8 uint Read 0 4.0000

6436 2 10 1 uint Read 0 4.0000

6438 2 10 2 uint Read 0 4.0000

6440 2 10 3 uint Read 0 4.0000

6442 2 10 4 uint Read 0 4.0000

6444 2 10 5 uint Read 0 4.0000

6446 2 10 6 uint Read 0 4.0000

6448 2 10 7 uint Read 0 4.0000

6450 2 10 8 uint Read 0 4.0000

6452 2 11 1 uint Read 0 4.0000

6454 2 11 2 uint Read 0 4.0000

6456 2 11 3 uint Read 0 4.0000

6458 2 11 4 uint Read 0 4.0000

6460 2 11 5 uint Read 0 4.0000

6462 2 11 6 uint Read 0 4.0000

6464 2 11 7 uint Read 0 4.0000

6466 2 11 8 uint Read 0 4.0000

6468 2 12 1 uint Read 0 4.0000

6470 2 12 2 uint Read 0 4.0000

6472 2 12 3 uint Read 0 4.0000

Page 97: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

95

Register Length Preset Component Data Type Read/Write Min Value Max Value

6474 2 12 4 uint Read 0 4.0000

6476 2 12 5 uint Read 0 4.0000

6478 2 12 6 uint Read 0 4.0000

6480 2 12 7 uint Read 0 4.0000

6482 2 12 8 uint Read 0 4.0000

5.2.20 Component Current BSW Hund

Register Length Preset Component Data Type Read/Write Min Value Max Value

6484 2 1 1 uint Read 0 65535

6486 2 1 2 uint Read 0 65535

6488 2 1 3 uint Read 0 65535

6490 2 1 4 uint Read 0 65535

6492 2 1 5 uint Read 0 65535

6494 2 1 6 uint Read 0 65535

6496 2 1 7 uint Read 0 65535

6498 2 1 8 uint Read 0 65535

6500 2 2 1 uint Read 0 65535

6502 2 2 2 uint Read 0 65535

6504 2 2 3 uint Read 0 65535

6506 2 2 4 uint Read 0 65535

6508 2 2 5 uint Read 0 65535

6510 2 2 6 uint Read 0 65535

6512 2 2 7 uint Read 0 65535

6514 2 2 8 uint Read 0 65535

6516 2 3 1 uint Read 0 65535

6518 2 3 2 uint Read 0 65535

6520 2 3 3 uint Read 0 65535

6522 2 3 4 uint Read 0 65535

6524 2 3 5 uint Read 0 65535

6526 2 3 6 uint Read 0 65535

6528 2 3 7 uint Read 0 65535

6530 2 3 8 uint Read 0 65535

6532 2 4 1 uint Read 0 65535

6534 2 4 2 uint Read 0 65535

6536 2 4 3 uint Read 0 65535

6538 2 4 4 uint Read 0 65535

6540 2 4 5 uint Read 0 65535

6542 2 4 6 uint Read 0 65535

6544 2 4 7 uint Read 0 65535

Page 98: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

96

Register Length Preset Component Data Type Read/Write Min Value Max Value

6546 2 4 8 uint Read 0 65535

6548 2 5 1 uint Read 0 65535

6550 2 5 2 uint Read 0 65535

6552 2 5 3 uint Read 0 65535

6554 2 5 4 uint Read 0 65535

6556 2 5 5 uint Read 0 65535

6558 2 5 6 uint Read 0 65535

6560 2 5 7 uint Read 0 65535

6562 2 5 8 uint Read 0 65535

6564 2 6 1 uint Read 0 65535

6566 2 6 2 uint Read 0 65535

6568 2 6 3 uint Read 0 65535

6570 2 6 4 uint Read 0 65535

6572 2 6 5 uint Read 0 65535

6574 2 6 6 uint Read 0 65535

6576 2 6 7 uint Read 0 65535

6578 2 6 8 uint Read 0 65535

6580 2 7 1 uint Read 0 65535

6582 2 7 2 uint Read 0 65535

6584 2 7 3 uint Read 0 65535

6586 2 7 4 uint Read 0 65535

6588 2 7 5 uint Read 0 65535

6590 2 7 6 uint Read 0 65535

6592 2 7 7 uint Read 0 65535

6594 2 7 8 uint Read 0 65535

6596 2 8 1 uint Read 0 65535

6598 2 8 2 uint Read 0 65535

6600 2 8 3 uint Read 0 65535

6602 2 8 4 uint Read 0 65535

6604 2 8 5 uint Read 0 65535

6606 2 8 6 uint Read 0 65535

6608 2 8 7 uint Read 0 65535

6610 2 8 8 uint Read 0 65535

6612 2 9 1 uint Read 0 65535

6614 2 9 2 uint Read 0 65535

6616 2 9 3 uint Read 0 65535

6618 2 9 4 uint Read 0 65535

6620 2 9 5 uint Read 0 65535

6622 2 9 6 uint Read 0 65535

6624 2 9 7 uint Read 0 65535

6626 2 9 8 uint Read 0 65535

Page 99: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

97

Register Length Preset Component Data Type Read/Write Min Value Max Value

6628 2 10 1 uint Read 0 65535

6630 2 10 2 uint Read 0 65535

6632 2 10 3 uint Read 0 65535

6634 2 10 4 uint Read 0 65535

6636 2 10 5 uint Read 0 65535

6638 2 10 6 uint Read 0 65535

6640 2 10 7 uint Read 0 65535

6642 2 10 8 uint Read 0 65535

6644 2 11 1 uint Read 0 65535

6646 2 11 2 uint Read 0 65535

6648 2 11 3 uint Read 0 65535

6650 2 11 4 uint Read 0 65535

6652 2 11 5 uint Read 0 65535

6654 2 11 6 uint Read 0 65535

6656 2 11 7 uint Read 0 65535

6658 2 11 8 uint Read 0 65535

6660 2 12 1 uint Read 0 65535

6662 2 12 2 uint Read 0 65535

6664 2 12 3 uint Read 0 65535

6666 2 12 4 uint Read 0 65535

6668 2 12 5 uint Read 0 65535

6670 2 12 6 uint Read 0 65535

6672 2 12 7 uint Read 0 65535

6674 2 12 8 uint Read 0 65535

5.2.21 Component Current API Gravity Tenths

Register Length Preset Component Data Type Read/Write Min Value Max Value

6676 2 1 1 int Read -100.00 1100.00

6678 2 1 2 int Read -100.00 1100.00

6680 2 1 3 int Read -100.00 1100.00

6682 2 1 4 int Read -100.00 1100.00

6684 2 1 5 int Read -100.00 1100.00

6686 2 1 6 int Read -100.00 1100.00

6688 2 1 7 int Read -100.00 1100.00

6690 2 1 8 int Read -100.00 1100.00

6692 2 2 1 int Read -100.00 1100.00

6694 2 2 2 int Read -100.00 1100.00

6696 2 2 3 int Read -100.00 1100.00

6698 2 2 4 int Read -100.00 1100.00

Page 100: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

98

Register Length Preset Component Data Type Read/Write Min Value Max Value

6700 2 2 5 int Read -100.00 1100.00

6702 2 2 6 int Read -100.00 1100.00

6704 2 2 7 int Read -100.00 1100.00

6706 2 2 8 int Read -100.00 1100.00

6708 2 3 1 int Read -100.00 1100.00

6710 2 3 2 int Read -100.00 1100.00

6712 2 3 3 int Read -100.00 1100.00

6714 2 3 4 int Read -100.00 1100.00

6716 2 3 5 int Read -100.00 1100.00

6718 2 3 6 int Read -100.00 1100.00

6720 2 3 7 int Read -100.00 1100.00

6722 2 3 8 int Read -100.00 1100.00

6724 2 4 1 int Read -100.00 1100.00

6726 2 4 2 int Read -100.00 1100.00

6728 2 4 3 int Read -100.00 1100.00

6730 2 4 4 int Read -100.00 1100.00

6732 2 4 5 int Read -100.00 1100.00

6734 2 4 6 int Read -100.00 1100.00

6736 2 4 7 int Read -100.00 1100.00

6738 2 4 8 int Read -100.00 1100.00

6740 2 5 1 int Read -100.00 1100.00

6742 2 5 2 int Read -100.00 1100.00

6744 2 5 3 int Read -100.00 1100.00

6746 2 5 4 int Read -100.00 1100.00

6748 2 5 5 int Read -100.00 1100.00

6750 2 5 6 int Read -100.00 1100.00

6752 2 5 7 int Read -100.00 1100.00

6754 2 5 8 int Read -100.00 1100.00

6756 2 6 1 int Read -100.00 1100.00

6758 2 6 2 int Read -100.00 1100.00

6760 2 6 3 int Read -100.00 1100.00

6762 2 6 4 int Read -100.00 1100.00

6764 2 6 5 int Read -100.00 1100.00

6766 2 6 6 int Read -100.00 1100.00

6768 2 6 7 int Read -100.00 1100.00

6770 2 6 8 int Read -100.00 1100.00

6772 2 7 1 int Read -100.00 1100.00

6774 2 7 2 int Read -100.00 1100.00

6776 2 7 3 int Read -100.00 1100.00

6778 2 7 4 int Read -100.00 1100.00

6780 2 7 5 int Read -100.00 1100.00

Page 101: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

99

Register Length Preset Component Data Type Read/Write Min Value Max Value

6782 2 7 6 int Read -100.00 1100.00

6784 2 7 7 int Read -100.00 1100.00

6786 2 7 8 int Read -100.00 1100.00

6788 2 8 1 int Read -100.00 1100.00

6790 2 8 2 int Read -100.00 1100.00

6792 2 8 3 int Read -100.00 1100.00

6794 2 8 4 int Read -100.00 1100.00

6796 2 8 5 int Read -100.00 1100.00

6798 2 8 6 int Read -100.00 1100.00

6800 2 8 7 int Read -100.00 1100.00

6802 2 8 8 int Read -100.00 1100.00

6804 2 9 1 int Read -100.00 1100.00

6806 2 9 2 int Read -100.00 1100.00

6808 2 9 3 int Read -100.00 1100.00

6810 2 9 4 int Read -100.00 1100.00

6812 2 9 5 int Read -100.00 1100.00

6814 2 9 6 int Read -100.00 1100.00

6816 2 9 7 int Read -100.00 1100.00

6818 2 9 8 int Read -100.00 1100.00

6820 2 10 1 int Read -100.00 1100.00

6822 2 10 2 int Read -100.00 1100.00

6824 2 10 3 int Read -100.00 1100.00

6826 2 10 4 int Read -100.00 1100.00

6828 2 10 5 int Read -100.00 1100.00

6830 2 10 6 int Read -100.00 1100.00

6832 2 10 7 int Read -100.00 1100.00

6834 2 10 8 int Read -100.00 1100.00

6836 2 11 1 int Read -100.00 1100.00

6838 2 11 2 int Read -100.00 1100.00

6840 2 11 3 int Read -100.00 1100.00

6842 2 11 4 int Read -100.00 1100.00

6844 2 11 5 int Read -100.00 1100.00

6846 2 11 6 int Read -100.00 1100.00

6848 2 11 7 int Read -100.00 1100.00

6850 2 11 8 int Read -100.00 1100.00

6852 2 12 1 int Read -100.00 1100.00

6854 2 12 2 int Read -100.00 1100.00

6856 2 12 3 int Read -100.00 1100.00

6858 2 12 4 int Read -100.00 1100.00

6860 2 12 5 int Read -100.00 1100.00

6862 2 12 6 int Read -100.00 1100.00

Page 102: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

100

Register Length Preset Component Data Type Read/Write Min Value Max Value

6864 2 12 7 int Read -100.00 1100.00

6866 2 12 8 int Read -100.00 1100.00

5.2.22 Component Current Mass Delivered

Register Length Preset Component Data Type Read/Write Min Value Max Value

6868 2 1 1 uint Read 0 65535

6870 2 1 2 uint Read 0 65535

6872 2 1 3 uint Read 0 65535

6874 2 1 4 uint Read 0 65535

6876 2 1 5 uint Read 0 65535

6878 2 1 6 uint Read 0 65535

6880 2 1 7 uint Read 0 65535

6882 2 1 8 uint Read 0 65535

6884 2 2 1 uint Read 0 65535

6886 2 2 2 uint Read 0 65535

6888 2 2 3 uint Read 0 65535

6890 2 2 4 uint Read 0 65535

Page 103: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

101

Chapter 6 Alarm Registers

This chapter outlines the register addresses for preset, meter, component and additive alarms.

See MultiLoad Communications manual for register definitions and hexadecimal bit mapping.

Alarm Messages

6.1.1 Bay Alarm Messages

Register Length Description Read/Write Data Type Min Value Max Value

2500 1 Modbus Bay Alarm Index Read/Write uint 0 65535

2501 1 Bay Alarm Base Level Read/Write uint 0 65535

2502 15 Bay Alarm Message Read/Write char 32 122

2517 1 Bay Alarm Promotion Count Read/Write uint 0 65535

2518 1 Bay Alarm Promoted Level Read/Write uint 0 65535

2519 1 Bay Alarm Count Reset Mode Read/Write uint 0 65535

6.1.2 Preset Alarm Messages

Register Length Description Read/Write Data Type

Min Value

Max Value

2520 1 Modbus Preset Alarm Index Read/Write uint 0 65535

2521 1 Preset Alarm Base Level Read/Write uint 0 65535

2522 15 Preset Alarm Message Read/Write char 32 122

2537 1 Preset Alarm Promotion Count Read/Write uint 0 65535

2538 1 Preset Alarm Promoted Level Read/Write uint 0 65535

2539 1 Preset Alarm Count Reset Mode Read/Write uint 0 65535

Chapter

6

Page 104: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

102

6.1.3 Meter Alarm Messages

Register Length Description Read/Write Data Type Min Value Max Value

2540 1 Modbus Meter Alarm Index Read/Write uint 0 65535

2541 1 Meter Alarm Base Level Read/Write uint 0 65535

2542 15 Meter Alarm Message Read/Write char 32 122

2557 1 Meter Alarm Promotion Count Read/Write uint 0 65535

2558 1 Meter Alarm Promoted Level Read/Write uint 0 65535

2559 1 Meter Alarm Count Reset Mode Read/Write uint 0 65535

6.1.4 Component Alarm Messages

Register Length Description Read/Write Data Type

Min Value

Max Value

2560 1 Modbus Component Alarm Index Read/Write uint 0 65535

2561 1 Component Alarm Base Level Read/Write uint 0 65535

2562 15 Component Alarm Message Read/Write char 32 122

2577 1 Component Alarm Promotion Count Read/Write uint 0 65535

2578 1 Component Alarm Promoted Level Read/Write uint 0 65535

2579 1 Component Alarm Count Reset Mode Read/Write uint 0 65535

6.1.5 Additive Alarm Messages

Register Length Description Read/Write Data Type Min Value Max Value

2580 1 Modbus Additive Alarm Index Read/Write uint 0 65535

2581 1 Additive Alarm Base Level Read/Write uint 0 65535

2582 15 Additive Alarm Message Read/Write char 32 122

2597 1 Additive Alarm Promotion Count Read/Write uint 0 65535

2598 1 Additive Alarm Promoted Level Read/Write uint 0 65535

2599 1 Additive Alarm Count Reset Mode Read/Write uint 0 65535

Trip Preset Alarms

Register Length Preset Data Type Read/Write Min Value Max Value

7082 1 1 uint Read 0 65535

7083 1 2 uint Read 0 65535

7084 1 3 uint Read 0 65535

7085 1 4 uint Read 0 65535

7086 1 5 uint Read 0 65535

7087 1 6 uint Read 0 65535

7088 1 7 uint Read 0 65535

Page 105: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

103

Register Length Preset Data Type Read/Write Min Value Max Value

7089 1 8 uint Read 0 65535

7090 1 9 uint Read 0 65535

7091 1 10 uint Read 0 65535

7092 1 11 uint Read 0 65535

7093 1 12 uint Read 0 65535

Request Alarms

6.3.1 Request Preset Alarms

Register Length Preset Data Type Read/Write Min Value Max Value

4024 1 1 uint Read 0 65535

4025 1 2 uint Read 0 65535

4026 1 3 uint Read 0 65535

4027 1 4 uint Read 0 65535

4028 1 5 uint Read 0 65535

4029 1 6 uint Read 0 65535

4030 1 7 uint Read 0 65535

4031 1 8 uint Read 0 65535

4032 1 9 uint Read 0 65535

4033 1 10 uint Read 0 65535

4034 1 11 uint Read 0 65535

4035 1 12 uint Read 0 65535

6.3.2 Request Bay Alarms

Register Length Description Data Type Read/Write Min Value Max Value

7094 1 Bay Alarm uint Read 0 65535

6.3.3 Request Component Alarms

Register Length Preset Component Data Type Read/Write Min Value Max Value

7095 1 1 1 uint Read 0 65535

7096 1 1 2 uint Read 0 65535

7097 1 1 3 uint Read 0 65535

7098 1 1 4 uint Read 0 65535

7099 1 1 5 uint Read 0 65535

7100 1 1 6 uint Read 0 65535

7101 1 1 7 uint Read 0 65535

7102 1 1 8 uint Read 0 65535

7103 1 2 1 uint Read 0 65535

7104 1 2 2 uint Read 0 65535

Page 106: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

104

Register Length Preset Component Data Type Read/Write Min Value Max Value

7105 1 2 3 uint Read 0 65535

7106 1 2 4 uint Read 0 65535

7107 1 2 5 uint Read 0 65535

7108 1 2 6 uint Read 0 65535

7109 1 2 7 uint Read 0 65535

7110 1 2 8 uint Read 0 65535

7111 1 3 1 uint Read 0 65535

7112 1 3 2 uint Read 0 65535

7113 1 3 3 uint Read 0 65535

7114 1 3 4 uint Read 0 65535

7115 1 3 5 uint Read 0 65535

7116 1 3 6 uint Read 0 65535

7117 1 3 7 uint Read 0 65535

7118 1 3 8 uint Read 0 65535

7119 1 4 1 uint Read 0 65535

7120 1 4 2 uint Read 0 65535

7121 1 4 3 uint Read 0 65535

7122 1 4 4 uint Read 0 65535

7123 1 4 5 uint Read 0 65535

7124 1 4 6 uint Read 0 65535

7125 1 4 7 uint Read 0 65535

7126 1 4 8 uint Read 0 65535

7127 1 5 1 uint Read 0 65535

7128 1 5 2 uint Read 0 65535

7129 1 5 3 uint Read 0 65535

7130 1 5 4 uint Read 0 65535

7131 1 5 5 uint Read 0 65535

7132 1 5 6 uint Read 0 65535

7133 1 5 7 uint Read 0 65535

7134 1 5 8 uint Read 0 65535

7135 1 6 1 uint Read 0 65535

7136 1 6 2 uint Read 0 65535

7137 1 6 3 uint Read 0 65535

7138 1 6 4 uint Read 0 65535

7139 1 6 5 uint Read 0 65535

7140 1 6 6 uint Read 0 65535

7141 1 6 7 uint Read 0 65535

7142 1 6 8 uint Read 0 65535

7143 1 7 1 uint Read 0 65535

7144 1 7 2 uint Read 0 65535

7145 1 7 3 uint Read 0 65535

Page 107: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

105

Register Length Preset Component Data Type Read/Write Min Value Max Value

7146 1 7 4 uint Read 0 65535

7147 1 7 5 uint Read 0 65535

7148 1 7 6 uint Read 0 65535

7149 1 7 7 uint Read 0 65535

7150 1 7 8 uint Read 0 65535

7151 1 8 1 uint Read 0 65535

7152 1 8 2 uint Read 0 65535

7153 1 8 3 uint Read 0 65535

7154 1 8 4 uint Read 0 65535

7155 1 8 5 uint Read 0 65535

7156 1 8 6 uint Read 0 65535

7157 1 8 7 uint Read 0 65535

7158 1 8 8 uint Read 0 65535

7159 1 9 1 uint Read 0 65535

7160 1 9 2 uint Read 0 65535

7161 1 9 3 uint Read 0 65535

7162 1 9 4 uint Read 0 65535

7163 1 9 5 uint Read 0 65535

7164 1 9 6 uint Read 0 65535

7165 1 9 7 uint Read 0 65535

7166 1 9 8 uint Read 0 65535

7167 1 10 1 uint Read 0 65535

7168 1 10 2 uint Read 0 65535

7169 1 10 3 uint Read 0 65535

7170 1 10 4 uint Read 0 65535

7171 1 10 5 uint Read 0 65535

7172 1 10 6 uint Read 0 65535

7173 1 10 7 uint Read 0 65535

7174 1 10 8 uint Read 0 65535

7175 1 11 1 uint Read 0 65535

7176 1 11 2 uint Read 0 65535

7177 1 11 3 uint Read 0 65535

7178 1 11 4 uint Read 0 65535

7179 1 11 5 uint Read 0 65535

7180 1 11 6 uint Read 0 65535

7181 1 11 7 uint Read 0 65535

7182 1 11 8 uint Read 0 65535

7183 1 12 1 uint Read 0 65535

7184 1 12 2 uint Read 0 65535

7185 1 12 3 uint Read 0 65535

7186 1 12 4 uint Read 0 65535

Page 108: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

106

Register Length Preset Component Data Type Read/Write Min Value Max Value

7187 1 12 5 uint Read 0 65535

7188 1 12 6 uint Read 0 65535

7189 1 12 7 uint Read 0 65535

7190 1 12 8 uint Read 0 65535

6.3.4 Request Meter Alarms

Register Length Preset Meter Data Type Read/Write Min Value Max Value

7191 1 1 1 uint Read 0 65535

7192 1 1 2 uint Read 0 65535

7193 1 1 3 uint Read 0 65535

7194 1 1 4 uint Read 0 65535

7195 1 1 5 uint Read 0 65535

7196 1 2 1 uint Read 0 65535

7197 1 2 2 uint Read 0 65535

7198 1 2 3 uint Read 0 65535

7199 1 2 4 uint Read 0 65535

7200 1 2 5 uint Read 0 65535

7201 1 3 1 uint Read 0 65535

7202 1 3 2 uint Read 0 65535

7203 1 3 3 uint Read 0 65535

7204 1 3 4 uint Read 0 65535

7205 1 3 5 uint Read 0 65535

7206 1 4 1 uint Read 0 65535

7207 1 4 2 uint Read 0 65535

7208 1 4 3 uint Read 0 65535

7209 1 4 4 uint Read 0 65535

7210 1 4 5 uint Read 0 65535

7211 1 5 1 uint Read 0 65535

7212 1 5 2 uint Read 0 65535

7213 1 5 3 uint Read 0 65535

7214 1 5 4 uint Read 0 65535

7215 1 5 5 uint Read 0 65535

7216 1 6 1 uint Read 0 65535

7217 1 6 2 uint Read 0 65535

7218 1 6 3 uint Read 0 65535

7219 1 6 4 uint Read 0 65535

7220 1 6 5 uint Read 0 65535

7221 1 7 1 uint Read 0 65535

7222 1 7 2 uint Read 0 65535

Page 109: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

107

Register Length Preset Meter Data Type Read/Write Min Value Max Value

7223 1 7 3 uint Read 0 65535

7224 1 7 4 uint Read 0 65535

7225 1 7 5 uint Read 0 65535

7226 1 8 1 uint Read 0 65535

7227 1 8 2 uint Read 0 65535

7228 1 8 3 uint Read 0 65535

7229 1 8 4 uint Read 0 65535

7230 1 8 5 uint Read 0 65535

7231 1 9 1 uint Read 0 65535

7232 1 9 2 uint Read 0 65535

7233 1 9 3 uint Read 0 65535

7234 1 9 4 uint Read 0 65535

7235 1 9 5 uint Read 0 65535

7236 1 10 1 uint Read 0 65535

7237 1 10 2 uint Read 0 65535

7238 1 10 3 uint Read 0 65535

7239 1 10 4 uint Read 0 65535

7240 1 10 5 uint Read 0 65535

7241 1 11 1 uint Read 0 65535

7242 1 11 2 uint Read 0 65535

7243 1 11 3 uint Read 0 65535

7244 1 11 4 uint Read 0 65535

7245 1 11 5 uint Read 0 65535

7246 1 12 1 uint Read 0 65535

7247 1 12 2 uint Read 0 65535

7248 1 12 3 uint Read 0 65535

7249 1 12 4 uint Read 0 65535

7250 1 12 5 uint Read 0 65535

6.3.5 Request Additive Alarms

Register Length Preset Additive Data Type Read/Write Min Value Max Value

7251 1 1 1 uint Read 0 65535

7252 1 1 2 uint Read 0 65535

7253 1 1 3 uint Read 0 65535

7254 1 1 4 uint Read 0 65535

7255 1 1 5 uint Read 0 65535

7256 1 1 6 uint Read 0 65535

7257 1 1 7 uint Read 0 65535

7258 1 1 8 uint Read 0 65535

Page 110: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

108

Register Length Preset Additive Data Type Read/Write Min Value Max Value

7259 1 1 9 uint Read 0 65535

7260 1 1 10 uint Read 0 65535

7261 1 1 11 uint Read 0 65535

7262 1 1 12 uint Read 0 65535

7263 1 1 13 uint Read 0 65535

7264 1 1 14 uint Read 0 65535

7265 1 1 15 uint Read 0 65535

7266 1 1 16 uint Read 0 65535

7267 1 2 1 uint Read 0 65535

7268 1 2 2 uint Read 0 65535

7269 1 2 3 uint Read 0 65535

7270 1 2 4 uint Read 0 65535

7271 1 2 5 uint Read 0 65535

7272 1 2 6 uint Read 0 65535

7273 1 2 7 uint Read 0 65535

7274 1 2 8 uint Read 0 65535

7275 1 2 9 uint Read 0 65535

7276 1 2 10 uint Read 0 65535

7277 1 2 11 uint Read 0 65535

7278 1 2 12 uint Read 0 65535

7279 1 2 13 uint Read 0 65535

7280 1 2 14 uint Read 0 65535

7281 1 2 15 uint Read 0 65535

7282 1 2 16 uint Read 0 65535

7283 1 3 1 uint Read 0 65535

7284 1 3 2 uint Read 0 65535

7285 1 3 3 uint Read 0 65535

7286 1 3 4 uint Read 0 65535

7287 1 3 5 uint Read 0 65535

7288 1 3 6 uint Read 0 65535

7289 1 3 7 uint Read 0 65535

7290 1 3 8 uint Read 0 65535

7291 1 3 9 uint Read 0 65535

7292 1 3 10 uint Read 0 65535

7293 1 3 11 uint Read 0 65535

7294 1 3 12 uint Read 0 65535

7295 1 3 13 uint Read 0 65535

7296 1 3 14 uint Read 0 65535

7297 1 3 15 uint Read 0 65535

7298 1 3 16 uint Read 0 65535

7299 1 4 1 uint Read 0 65535

Page 111: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

109

Register Length Preset Additive Data Type Read/Write Min Value Max Value

7300 1 4 2 uint Read 0 65535

7301 1 4 3 uint Read 0 65535

7302 1 4 4 uint Read 0 65535

7303 1 4 5 uint Read 0 65535

7304 1 4 6 uint Read 0 65535

7305 1 4 7 uint Read 0 65535

7306 1 4 8 uint Read 0 65535

7307 1 4 9 uint Read 0 65535

7308 1 4 10 uint Read 0 65535

7309 1 4 11 uint Read 0 65535

7310 1 4 12 uint Read 0 65535

7311 1 4 13 uint Read 0 65535

7312 1 4 14 uint Read 0 65535

7313 1 4 15 uint Read 0 65535

7314 1 4 16 uint Read 0 65535

7315 1 5 1 uint Read 0 65535

7316 1 5 2 uint Read 0 65535

7317 1 5 3 uint Read 0 65535

7318 1 5 4 uint Read 0 65535

7319 1 5 5 uint Read 0 65535

7320 1 5 6 uint Read 0 65535

7321 1 5 7 uint Read 0 65535

7322 1 5 8 uint Read 0 65535

7323 1 5 9 uint Read 0 65535

7324 1 5 10 uint Read 0 65535

7325 1 5 11 uint Read 0 65535

7326 1 5 12 uint Read 0 65535

7327 1 5 13 uint Read 0 65535

7328 1 5 14 uint Read 0 65535

7329 1 5 15 uint Read 0 65535

7330 1 5 16 uint Read 0 65535

7331 1 6 1 uint Read 0 65535

7332 1 6 2 uint Read 0 65535

7333 1 6 3 uint Read 0 65535

7334 1 6 4 uint Read 0 65535

7335 1 6 5 uint Read 0 65535

7336 1 6 6 uint Read 0 65535

7337 1 6 7 uint Read 0 65535

7338 1 6 8 uint Read 0 65535

7339 1 6 9 uint Read 0 65535

7340 1 6 10 uint Read 0 65535

Page 112: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

110

Register Length Preset Additive Data Type Read/Write Min Value Max Value

7341 1 6 11 uint Read 0 65535

7342 1 6 12 uint Read 0 65535

7343 1 6 13 uint Read 0 65535

7344 1 6 14 uint Read 0 65535

7345 1 6 15 uint Read 0 65535

7346 1 6 16 uint Read 0 65535

7347 1 7 1 uint Read 0 65535

7348 1 7 2 uint Read 0 65535

7349 1 7 3 uint Read 0 65535

7350 1 7 4 uint Read 0 65535

7351 1 7 5 uint Read 0 65535

7352 1 7 6 uint Read 0 65535

7353 1 7 7 uint Read 0 65535

7354 1 7 8 uint Read 0 65535

7355 1 7 9 uint Read 0 65535

7356 1 7 10 uint Read 0 65535

7357 1 7 11 uint Read 0 65535

7358 1 7 12 uint Read 0 65535

7359 1 7 13 uint Read 0 65535

7360 1 7 14 uint Read 0 65535

7361 1 7 15 uint Read 0 65535

7362 1 7 16 uint Read 0 65535

7363 1 8 1 uint Read 0 65535

7364 1 8 2 uint Read 0 65535

7365 1 8 3 uint Read 0 65535

7366 1 8 4 uint Read 0 65535

7367 1 8 5 uint Read 0 65535

7368 1 8 6 uint Read 0 65535

7369 1 8 7 uint Read 0 65535

7370 1 8 8 uint Read 0 65535

7371 1 8 9 uint Read 0 65535

7372 1 8 10 uint Read 0 65535

7373 1 8 11 uint Read 0 65535

7374 1 8 12 uint Read 0 65535

7375 1 8 13 uint Read 0 65535

7376 1 8 14 uint Read 0 65535

7377 1 8 15 uint Read 0 65535

7378 1 8 16 uint Read 0 65535

7379 1 9 1 uint Read 0 65535

7380 1 9 2 uint Read 0 65535

7381 1 9 3 uint Read 0 65535

Page 113: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

111

Register Length Preset Additive Data Type Read/Write Min Value Max Value

7382 1 9 4 uint Read 0 65535

7383 1 9 5 uint Read 0 65535

7384 1 9 6 uint Read 0 65535

7385 1 9 7 uint Read 0 65535

7386 1 9 8 uint Read 0 65535

7387 1 9 9 uint Read 0 65535

7388 1 9 10 uint Read 0 65535

7389 1 9 11 uint Read 0 65535

7390 1 9 12 uint Read 0 65535

7391 1 9 13 uint Read 0 65535

7392 1 9 14 uint Read 0 65535

7393 1 9 15 uint Read 0 65535

7394 1 9 16 uint Read 0 65535

7395 1 10 1 uint Read 0 65535

7396 1 10 2 uint Read 0 65535

7397 1 10 3 uint Read 0 65535

7398 1 10 4 uint Read 0 65535

7399 1 10 5 uint Read 0 65535

7400 1 10 6 uint Read 0 65535

7401 1 10 7 uint Read 0 65535

7402 1 10 8 uint Read 0 65535

7403 1 10 9 uint Read 0 65535

7404 1 10 10 uint Read 0 65535

7405 1 10 11 uint Read 0 65535

7406 1 10 12 uint Read 0 65535

7407 1 10 13 uint Read 0 65535

7408 1 10 14 uint Read 0 65535

7409 1 10 15 uint Read 0 65535

7410 1 10 16 uint Read 0 65535

7411 1 11 1 uint Read 0 65535

7412 1 11 2 uint Read 0 65535

7413 1 11 3 uint Read 0 65535

7414 1 11 4 uint Read 0 65535

7415 1 11 5 uint Read 0 65535

7416 1 11 6 uint Read 0 65535

7417 1 11 7 uint Read 0 65535

7418 1 11 8 uint Read 0 65535

7419 1 11 9 uint Read 0 65535

7420 1 11 10 uint Read 0 65535

7421 1 11 11 uint Read 0 65535

7422 1 11 12 uint Read 0 65535

Page 114: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

112

Register Length Preset Additive Data Type Read/Write Min Value Max Value

7423 1 11 13 uint Read 0 65535

7424 1 11 14 uint Read 0 65535

7425 1 11 15 uint Read 0 65535

7426 1 11 16 uint Read 0 65535

7427 1 12 1 uint Read 0 65535

7428 1 12 2 uint Read 0 65535

7429 1 12 3 uint Read 0 65535

7430 1 12 4 uint Read 0 65535

7431 1 12 5 uint Read 0 65535

7432 1 12 6 uint Read 0 65535

7433 1 12 7 uint Read 0 65535

7434 1 12 8 uint Read 0 65535

7435 1 12 9 uint Read 0 65535

7436 1 12 10 uint Read 0 65535

7437 1 12 11 uint Read 0 65535

7438 1 12 12 uint Read 0 65535

7439 1 12 13 uint Read 0 65535

7440 1 12 14 uint Read 0 65535

7441 1 12 15 uint Read 0 65535

7442 1 12 16 uint Read 0 65535

Page 115: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

113

Chapter 7 Preset Status Registers

This chapter outlines the register address for Preset State and Status.

See MultiLoad Communications manual for register definitions and hexadecimal bit mapping.

Preset State

Register Length Preset Data Type Read/Write Min Value Max Value

4000 1 1 uint Read 0 99

4001 1 2 uint Read 0 99

4002 1 3 uint Read 0 99

4003 1 4 uint Read 0 99

4004 1 5 uint Read 0 99

4005 1 6 uint Read 0 99

4006 1 7 uint Read 0 99

4007 1 8 uint Read 0 99

4008 1 9 uint Read 0 99

4009 1 10 uint Read 0 99

4010 1 11 uint Read 0 99

4011 1 12 uint Read 0 99

Preset Status

Register Length Preset Data Type Read/Write Min Value Max Value

4012 1 1 uint Read 0 65535

4013 1 2 uint Read 0 65535

4014 1 3 uint Read 0 65535

4015 1 4 uint Read 0 65535

4016 1 5 uint Read 0 65535

4017 1 6 uint Read 0 65535

4018 1 7 uint Read 0 65535

4019 1 8 uint Read 0 65535

4020 1 9 uint Read 0 65535

4021 1 10 uint Read 0 65535

Chapter

7

Page 116: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

114

Register Length Preset Data Type Read/Write Min Value Max Value

4022 1 11 uint Read 0 65535

4023 1 12 uint Read 0 65535

State/Status Registers

Register Length Description Read/Write Data Type Min Value Max Value

7000 1 RCU State Read uint 0 65535

7001 1 Card Status Read uint 0 65535

7002 1 RCU Status Read uint 0 65535

Start Preset Flow

Register Length Preset Data Type Read/Write Min Value Max Value

7443 1 1 uint Read 0 65535

7444 1 2 uint Read 0 65535

7445 1 3 uint Read 0 65535

7446 1 4 uint Read 0 65535

7447 1 5 uint Read 0 65535

7448 1 6 uint Read 0 65535

7449 1 7 uint Read 0 65535

7450 1 8 uint Read 0 65535

7451 1 9 uint Read 0 65535

7452 1 10 uint Read 0 65535

7453 1 11 uint Read 0 65535

7454 1 12 uint Read 0 65535

Stop Preset Flow

Register Length Preset Data Type Read/Write Min Value Max Value

7455 1 1 uint Read 0 65535

7456 1 2 uint Read 0 65535

7457 1 3 uint Read 0 65535

7458 1 4 uint Read 0 65535

7459 1 5 uint Read 0 65535

7460 1 6 uint Read 0 65535

7461 1 7 uint Read 0 65535

7462 1 8 uint Read 0 65535

7463 1 9 uint Read 0 65535

7464 1 10 uint Read 0 65535

7465 1 11 uint Read 0 65535

Page 117: MultiLoad Modbus Mapping - Amazon S3

MULTILOAD II – MODBUS MAPPING

115

Register Length Preset Data Type Read/Write Min Value Max Value

7466 1 12 uint Read 0 65535