MultiLoad II SMP Installation Guide v1-2

56
M M u u l l t t i i L L o o a a d d I I I I S S i i n n g g l l e e M M e e t t e e r r P P r r e e s s e e t t Installation Guide Version 1.2 - Part # 6067 December 19, 2008

Transcript of MultiLoad II SMP Installation Guide v1-2

  • MMuullttiiLLooaadd IIII SSiinnggllee MMeetteerr PPrreesseett

    Installation Guide

    Version 1.2 - Part # 6067 December 19, 2008

  • 2

    EC Declaration Of Conformity the product listed below conforms to the relevant provisions of the following directives: 2004/108/EC The Electromagnetic Compatibility Directive (and its amending directives) 94/9/EEC The Potentially Explosive Atmospheres Directive (and its amending directives) Product: Process Controller with Operator Interface intended for use in potentially explosive atmospheres Model name/number: MultiLoad II SMP Protective Systems: Flameproof d, Intrinsic Safety ib Notified Body: Demko A/S Testing and Certification, Number 0539

    P.O. Box 514 Lyskaer 8 DK-2730 Herlev, Denmark

    Conformity has been demonstrated with reference to the following documentation: EC type-examination certificate 06 ATEX 0619833X Compliance with the Essential Health and Safety Requirements has been assessed by reference to the following standards: EN 61000-6-4: 2007 Generic emissions for industrial operating environments EN 61000-6-2: 2005 Generic immunity for industrial operating environments EN 60079-0: 2006 Electrical apparatus for explosive gas atmospheresGeneral requirements EN 60079-1: 2004 Electrical apparatus for explosive gas atmospheres Flameproof enclosures d EN 50020: 2002 Electrical apparatus for potentially explosive atmospheresIntrinsic safety i

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • 3

    ELECTRICAL CONSIDERATIONS AND REGULATORY REQUIREMENTS

    ! A battery is soldered to the CPU board and provides nonvolatile data storage and time/date retention. This battery should last between ten and thirteen years and is a factory replaceable part. This battery must be replaced with Matsushita Electric, model BR2477A only. Use of another battery may present a risk of fire or explosion.

    !

    CAUTION: Battery may explode if mistreated. DO NOT RECHARGE, DISASSEMBLE, OR DISPOSE OF IN FIRE.

    ! CAUTION: Use supply wires suitable for 5C above surrounding ambient.

    This equipment is suitable for use in Class I, Division 1, Groups C and D locations, Ex Zone I Group IIB locations, OR non-hazardous locations. !

    WARNING: EXPLOSION HAZARD. Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous.

    !

    WARNING: EXPLOSION HAZARD. The area must be known to be non-hazardous before servicing/replacing the unit and before installing.

    !

    WARNING: TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, conduit runs must have a sealing fitting connected within 18 inches of the enclosure.

    !

    WARNING: TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, disconnect from the supply circuit before opening enclosure. Keep tightly closed when circuits are live.

    !

    WARNING: Substitution of components may impair intrinsic safety.

    !

    WARNING: Consult installation manual for required cable entry size and thread.

    !

    WARNING: If there are unused holes, blanking elements satisfying the flameproof d method of protection must be used. Blanking elements must be removable with the aide of a tool, ATEX certified, suitable for Gas Group IIB and suitable for an ambient temperature range of -40 C to +60 C.

    Underwriters Laboratories, Inc. (UL) has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested for fire, shock and/or casualty hazards as outlined in UL's UL508, UL1203, and UL 913 Standards for Safety. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product.

    UL MAKES NO REPRESENTATIONS, WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • 4

    Copyright Notice Copyright 2006 - 2008 Toptech Systems, Inc.

    The information contained in this document is proprietary and confidential. No part of this document may be copied, reproduced, or transmitted in any medium without the express written permission of Toptech Systems, Inc.

    Disclaimer Toptech Systems assumes no responsibility for damages resulting from installation or use of its products. Toptech Systems will not be liable for any claims of damage, lost data, or lost time as a result of using its products.

    Toptech

    Systems, Inc. logo is a registered trademark of Toptech Systems, Inc.

    TMS, TMS5, TMS6, RCU II Remote Control Unit, Toptech MultiLoad II, MultiLoad II -RCU, FCM Flow Control Module are trademarks of Toptech Systems, Inc.

    Copyright 2008 Toptech Systems, Inc. All Rights Reserved.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • 5

    Table of Contents

    Electrical Considerations and Regulatory Requirements ............................................................................... 3 CHAPTER 1 General.......................................................................................................................................... 8

    1.1 Product Specification MultiLoad II SMP:............................................................................................ 8 1.1.1 Local (stand-alone) Mode...................................................................................................................... 8 1.1.2 Remote Processing Mode ..................................................................................................................... 9

    1.2 Information Alerts:................................................................................................................................. 10 1.2.1 Typographical Conventions: ................................................................................................................ 10 1.2.2 Receiving and/or Returning Equipment:.............................................................................................. 10

    1.3 Electrostatic Discharge (ESD) Protection:.......................................................................................... 11 CHAPTER 2 Installing the SMP...................................................................................................................... 12

    2.1 Tools Required....................................................................................................................................... 12 2.1.1 Installation............................................................................................................................................ 12 2.1.2 Servicing and Repair ........................................................................................................................... 12

    2.2 Mounting SMP Enclosure: .................................................................................................................... 12 2.2.1 Metal Plate or Rail: .............................................................................................................................. 12 2.2.2 Wood:................................................................................................................................................... 12 2.2.3 Concrete or Cinder Block:.................................................................................................................... 12

    2.3 Recommended Wire Sizes And Torque For All Terminal Blocks ..................................................... 13 2.4 Electrical Supply Connections............................................................................................................. 14

    2.4.1 AC Power:............................................................................................................................................ 14 2.4.2 DC Power (option): .............................................................................................................................. 17 2.4.3 Equipment Grounding:......................................................................................................................... 17 2.4.4 Cable Gland Entries:............................................................................................................................ 17

    CHAPTER 3 Data Communications Interface............................................................................................... 18 3.1 Communications Protocol Selection and Connection: ..................................................................... 19

    3.1.1 RS-422/485:......................................................................................................................................... 19 3.1.2 RS-232................................................................................................................................................. 19 3.1.3 Host/TMS Communications (COM 1 - RS-485 4-wire)........................................................................ 20 3.1.4 Host/TMS Communications (COM 1 - RS-485 2-wire)........................................................................ 21 3.1.5 Host/TMS Communications (COM 1 - RS-232)................................................................................... 22 3.1.6 Host Ticket Printer/Data Logger (COM 2 - RS-232)............................................................................ 23 3.1.7 Ethernet ............................................................................................................................................... 24

    CHAPTER 4 I/O Configuration ....................................................................................................................... 25 4.1 Connecting Field Devices to the I/O Board......................................................................................... 25

    4.1.1 TB2A +12 Vdc Supply ......................................................................................................................... 27 4.1.2 TB2B DC Inputs................................................................................................................................... 28 4.1.3 TB3 DC Outputs .................................................................................................................................. 30 4.1.4 TB4 RTD Input..................................................................................................................................... 31 4.1.5 TB1 AC Outputs................................................................................................................................... 32 4.1.6 TB5-Analog Input................................................................................................................................. 33 4.1.7 TB6-Analog Output .............................................................................................................................. 34

    CHAPTER 5 Configuration ............................................................................................................................. 35 5.1 Navigating the System: ......................................................................................................................... 35

    5.1.1 SMP Keypad:....................................................................................................................................... 35 5.1.2 Switch Access Control (Option)........................................................................................................... 35 5.1.3 Type 1 Program / W&M switches ........................................................................................................ 36 5.1.4 Type 2 Program / W&M switches ........................................................................................................ 37

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • 6

    5.1.5 Type 3 Program / W&M switches ........................................................................................................ 38 5.1.6 Program Mode / W&M DIP Switch ...................................................................................................... 39 5.1.7 Program Mode / W&M Field Switches................................................................................................. 40 5.1.8 Menus and Screens............................................................................................................................. 41 5.1.9 Field Modification and Data Entry........................................................................................................ 42

    5.2 SMP Preliminary Configuration: .......................................................................................................... 44 5.3 Verify Communications Between SMP And I/O Board: ..................................................................... 46

    CHAPTER 6 Service and Repair .................................................................................................................... 47 6.1.1 Modular Design:................................................................................................................................... 47 6.1.2 Operating the Flat Display Cable Connectors: .................................................................................... 48 6.1.3 CPU Subassembly Removal and Replacement: ................................................................................. 50 6.1.4 Display Subassembly Removal and Replacement:............................................................................. 51 6.1.5 Keypad Removal and Replacement: ................................................................................................... 51 6.1.6 Keypad Barrier Circuit Removal and Replacement:............................................................................ 51

    CHAPTER 7 Appendix..................................................................................................................................... 52

    Table of Figures

    Figure 2.1 MultiLoad II Terminal Block Recommended Wire Size and Screw Torque..................................... 13 Figure 2.2 MultiLoad II AC Power Supply/Comm Board................................................................................... 15 Figure 2.3 AC Supply Terminal Block Access .................................................................................................. 16 Figure 2.4 Removal of AC Wiring Side Partition............................................................................................... 16 Figure 2.5 Replacement of AC Wiring Side Partition........................................................................................ 16 Figure 2.6 DC Power Connections ................................................................................................................... 17 Figure 3.1 RS485 4-Wire, Host to a Single MultiLoad II (recommended) ........................................................ 20 Figure 3.2 RS485 4-Wire, Host to Multiple MultiLoad IIs.................................................................................. 20 Figure 3.3 RS485 2-Wire, Host to a Single MultiLoad II ................................................................................... 21 Figure 3.4 RS485 4-Wire, Host to Multiple MultiLoad IIs.................................................................................. 21 Figure 3.5 RS232, Host to a Single MultiLoad II............................................................................................... 22 Figure 3.6 RS232, Host to Multiple MultiLoad IIs ............................................................................................. 22 Figure 3.7 Ticket Printer / Data Logger Connections with Handshake............................................................. 23 Figure 3.8 Ticket Printer / Data Logger Connections without Handshake........................................................ 23 Figure 3.9 Ethernet Connections ...................................................................................................................... 24 Figure 4.1 Connections to I/O Board ................................................................................................................ 26 Figure 4.2 TB2A + 12 Vdc Supply Assignments............................................................................................... 27 Figure 4.3 +12 Vdc Supply Voltage .................................................................................................................. 27 Figure 4.4 TB2B DC Input Assignments........................................................................................................... 28 Figure 4.5 DC Inputs ......................................................................................................................................... 28 Figure 4.6 Product Meter and Permissive......................................................................................................... 29 Figure 4.7 Additive Meter.................................................................................................................................. 29 Figure 4.8 TB3 DC Outputs Assignments......................................................................................................... 30 Figure 4.9 DC Outputs ...................................................................................................................................... 30 Figure 4.10 TB4 RTD Input Assignments ........................................................................................................... 31

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • 7

    Figure 4.11 RTD Connection .............................................................................................................................. 31 Figure 4.12 TB1 AC Output Assignments........................................................................................................... 32 Figure 4.13 Digital Control Valve and Additive Connections .............................................................................. 32 Figure 4.14 TB6 Analog Current Input Assignments .......................................................................................... 33 Figure 4.15 Analog Current Input........................................................................................................................ 33 Figure 4.16 TB6 Analog Output Assignments .................................................................................................... 34 Figure 4.17 Analog Current Output..................................................................................................................... 34 Figure 4.18 Analog Voltage Output..................................................................................................................... 34 Figure 5.1 Type 1 Program / W&M Switches.................................................................................................... 36 Figure 5.2 Type 2 Program / W&M Switches.................................................................................................... 37 Figure 5.3 Type 3 Program / W&M Switches.................................................................................................... 38 Figure 5.4 CPU Board Program and W&M DIP Switches ................................................................................ 39 Figure 5-5 Program and Weights and Measures Switch .................................................................................. 40 Figure 6.1 Cam lock in the Open (Up) position................................................................................................. 48 Figure 6.2 Display Cable Insertion.................................................................................................................... 49 Figure 6.3 Cam lock in the closed (down) position ........................................................................................... 49 Figure 7.1 Unit Outline Drawing Front View .................................................................................................. 52 Figure 7.2 Unit Outline Drawing Bottom View ............................................................................................... 52 Figure 7.3 Unit Outline Drawing Side View.................................................................................................... 53 Figure 7.4 Replacement Parts SMP Base Drawing.......................................................................................... 53 Figure 7.5 Exploded view front panel assembly ............................................................................................... 54 Figure 7.6 Microprocessor Board...................................................................................................................... 54 Figure 7.7 Power Supply Board ........................................................................................................................ 55 Figure 7.8 I/O Board.......................................................................................................................................... 55 Figure 7.9 Power Supply / Comm Board & I/O Board Chassis ........................................................................ 56

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 1 General 8

    CHAPTER 1 GENERAL

    1.1 PRODUCT SPECIFICATION MULTILOAD II SMP:

    The MultiLoad II SMP (SMP) is designed to manage one arm, straight product loading. The system can operate in conjunction with the Toptech TMS system (remote processing mode) or in Local (stand alone) Mode. The SMP supports:

    Single meter/single product loading

    Two additive injectors

    Digital or analog control valves

    RTD input

    4-20 mA input for either density or pressure

    Ethernet communications

    1.1.1 LOCAL (STAND-ALONE) MODE

    Product and access information are stored in non-volatile memory. The SMP prompts the driver for a driver number and Personal Identification Number (PIN). The PIN must match the driver PIN stored in the SMP database. After the PIN has been verified the SMP contains up to four configurable prompts that can be presented to the driver. After recording the data entry prompts, a load will be authorized.

    Capabilities include:

    300 driver/access IDs and associated PINs.

    200 transaction archives complete with salable product, component detail and additive detail.

    4 user-configuration custom prompts; resultant data stored with each transaction.

    33 product recipes.

    Meter ticket combined ticket for all transaction listings in user configurable format.

    Meter, additive, pressure, density and temperature calibration features.

    Log of the last 1000 Weights and Measures parameter changes.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 1 General 9

    1.1.2 REMOTE PROCESSING MODE

    Product and access control comes from TMS or remote computer systems. The number of driver records, customer prompts and recipes is virtually unlimited.

    For product outline and dimensions see Appendix Figures 6.1 to 6.3.

    Operating voltage: 85 - 250 Vac, 47-63 Hz, 300 150 mA OR

    18 - 36 Vdc, 600mA

    Operating temperature (without heater): -22F to 140F (-25C to 60C).

    (with heater): -40F to 140F (-40C to 60C).

    Explosion proof enclosure:

    Type 4, IP65

    UL Listed, Class 1, Division 1, Groups C & D

    ATEX Certified Group IIB, T4, Category 2G

    Weight: 26 lbs (12 kg)

    Display: Color 4 Diagonal, QVGA

    Communications:

    3 serial ports (1 RS-232, 1 RS-485, 1 User Selectable RS-232 or RS-485)

    1 Ethernet port 10/100 MBPS

    I/O Board provides following:

    13 Digital I/O Electrical Range

    5 AC Outputs 12 250Vac, 47 63Hz, 500mA per point

    5 DC Inputs (3 high speed counters) 5 30Vdc

    3 DC Outputs (1 Pulse output) 0 30Vdc, 600mA per point

    2 Analog Inputs 1 4-wire 100 Ohm RTD, 1 4-20mA

    1 Analog Output 1 4-20mA

    Options:

    24 Vdc Power Supply

    Program/Weights & Measures Switch

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 1 General 10

    1.2 INFORMATION ALERTS:

    !

    Important information to enhance understanding and make better use of the product. 2 Indicates potential damage to hardware or loss of data. Potential for property damage or that personal injury may occur. Pay close attention and follow instructions when you see this symbol.

    1.2.1 TYPOGRAPHICAL CONVENTIONS:

    Boldface: Indicates what you are to press on the keypad. Example: Key in 00000.

    Italics: Emphasizes a key product or industry term. Example: the display features a pick list style of item selection.

    1.2.2 RECEIVING AND/OR RETURNING EQUIPMENT:

    The SMP should be immediately inspected after opening the packaging case. If any damage is visible notify the carrier at once to establish liability. Contact Toptech Account Management to initiate timely repair or replacement of the unit. Parts requiring repair or replacement can be identified from Appendix Figures 6.4 6.8.

    Account Management will issue a Return Materials Authorization (RMA) to return the product or parts requiring repair. Do not return any material to Toptech without an RMA.

    Account Management contact information:

    Account Management Toptech Systems 280 Hunt Park Cove Longwood, FL (407) 332-1774

    Prior to installation the SMP should be stored in its packing case and be protected from damage due to handling and adverse weather conditions.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 1 General 11

    1.3 ELECTROSTATIC DISCHARGE (ESD) PROTECTION:

    The SMP contains electronic components and assemblies subject to damage by ESD. The SMP was designed to protect against ESD while the unit is closed and in normal operation. Proper handling procedures must be observed during the removal, installation, repair and other handling of printed circuit board assemblies, electronic devices and components to include:

    1) Service to be performed by authorized personnel only.

    2) The person performing the service must be grounded by an ESD grounding strap and connected to ground.

    3) While performing maintenance or repair, touch an unpainted metal of the SMP surface prior to touching or handling any printed circuit boards or electronic components.

    4) Printed circuit board assemblies must be placed in and transported in conductive bags or other conductive containers.

    5) Printed circuit boards must not be removed from the conductive container until time of use.

    6) All other best practices for protecting devices from ESD must be observed.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 2 Installing the MultiLoad II Div2 12

    CHAPTER 2 INSTALLING THE SMP

    2.1 TOOLS REQUIRED

    2.1.1 INSTALLATION

    - 6 mm hex wrench required for tightening cover bolts

    2.1.2 SERVICING AND REPAIR

    - #4 Philips screwdriver for circuit board removal

    - socket wrench for CPU circuit board removal, 5/16 socket wrench for display board removal

    - Torx T15 for removal of keypad bezel security screws

    2.2 MOUNTING SMP ENCLOSURE:

    The SMP enclosure should be located in a shaded area. Direct sunlight can increase internal temperature to greater than 140 F or 60 C.

    Exterior dimensions of the enclosure are shown in Appendix Figures 6.1 through 6.3. Cable entries (5) M20x 1.5 mm are located at the bottom of the enclosure. The enclosure cover is secured by (12) 8 mm hex cap screws. When the screws are loosened, the front cover will swing left and hang from its hinges. A 6mm Allen head wrench is required to remove the screws.

    Fasteners must be selected to support the weight of the enclosure (26 lbs or 12 kg). Mounting suggestions include:

    2.2.1 METAL PLATE OR RAIL:

    Four hex head 5/16 OD (M8) bolts with a 5/16 flat washer, OD (M8, 18mm OD) under the head of the bolt. Fasten with four 5/16 (M8) hex nuts.

    2.2.2 WOOD:

    Same as metal plate above or

    Four hex head 2 X 5/16 OD (M8 x 50 mm) lag bolts with a 5/16 flat washer, OD (M8, 18 mm OD) under the head of the bolt.

    2.2.3 CONCRETE OR CINDER BLOCK:

    Four x 2 1/4 Tapcon, 5/8 diameter hex flange head masonry fasteners with a flat washer, OD under the head of the screw.

    Pre-drill for Tapcons using a 3/16 masonry drill bit.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 2 Installing the MultiLoad II Div2 13

    2.3 RECOMMENDED WIRE SIZES AND TORQUE FOR ALL TERMINAL BLOCKS

    Three sizes of terminal blocks are used in the MultiLoad II products: 7.62 mm pitch (supply power), 5.08 mm pitch (line voltage switching), and 3.81 mm pitch (serial communication, analog or dc voltages). All sizes, orientations, and manufacturer brands have different torque and wire size specifications. Please follow the recommendations in Figure 2.1 below. The manufacturer may be determined by looking for the logo molded into the terminal block, usually on the side.

    [mm] [AWG] [Nm] [LB in]Phoenix 7.62 Straight 30 - 12 .6 - .8 5 - 7

    On-Shore Technology

    7.62 Straight 24 - 12 0.40 3.5

    Sauro 7.62 Straight 30 - 12 0.8 7

    Phoenix 5.08 Straight 30 - 12 .6 - .8 5 - 7

    On-Shore Technology

    5.08 Straight 24 - 12 0.40 3.5

    Sauro 5.08 Straight 30 - 12 0.8 7

    Phoenix 3.81 Straight 30 - 14 0.5 4

    On-Shore Technology

    3.81 Straight 28 - 16 0.19 1.7

    Phoenix 3.81 90 30 - 14 0.2 - 0.5 2 - 4

    On-Shore Technology

    3.81 90 26 - 16 0.3 3

    Sauro 3.81 90 30 - 14 0.31 2.7

    TB2A, TB2B, I/O Board

    Manufacturer Orienta-tion

    Logo Recommended Screw Torque

    Location

    TB1, Power Supply Board

    TB1, I/O Board

    Terminal Block Pitch

    Allowable Wire Size

    TB2 - TB5, Power Supply Board; TB3 -TB6, I/O Board

    Figure 2.1 MultiLoad II Terminal Block Recommended Wire Size and Screw Torque

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 2 Installing the MultiLoad II Div2 14

    2.4 ELECTRICAL SUPPLY CONNECTIONS

    !!!

    2 The SMP may be equipped for either 85 -250Vac or 24Vdc operation. Verify the power type before making any connections. To reduce the risk of ignition in hazardous atmospheres, conduit runs must have seals Installed within 18 inches (45 cm) of the enclosure.

    UL requires that field wiring is rated 75C or greater.

    Canada requires that supply wires are rated at least 5C above surrounding ambient.

    Do not route AC and DC wiring in the same conduit.

    All wiring must enter the MultiLoad II enclosure through conduit via entries in the bottom of the enclosure. All conduits must be terminated at the enclosure by use of appropriately rated conduit hubs or glands.

    Wires must be stripped and fully inserted into terminal block with no bare conductor exposed. The terminal blocks are designed to accept wires sizes 12 AWG (3.31 mm2) through 24 AWG (0.205 mm2). The recommended tightening torque is 0.5 Nm [4.4 inch-pound force] to 0.6 Nm [5.3 inch pound-force].

    Both ac and dc input models require a safety ground connection as described in section 2.3.3 below.

    A service loop is recommended for all wires and cables entering the enclosure.

    2 Do not allow service loop cables to overlap the circuit boards. Coil any cable length in the bottom of the enclosure. Keep AC wiring separated from all other wiring in the enclosure by use of the supplied partitions (see wire partition instructions below).

    Wiring must comply with all local electrical codes.

    2.4.1 AC POWER:

    Provide over current protection using a 15 Amp circuit breaker or equivalent. The breaker also serves as a means of disconnection from the operating supply as required by UL/ISA/IEC 61010-1 and CAN/CSA-C22.2 NO. 61010-1. The disconnect device may not be blocked or be made difficult to operate by the MultiLoad II or any other device. Note that installation of disconnects are typically prohibited in Class I, Division 2 locations.

    Power required: 85 250 Vac, 47 63 Hz, 300 mA @ 85Vac/ 150 mA @250Vac. The power connector is located in the right hand corner of the Power Supply/Communication board as shown in figure 2.1. Select supply wire rated 300V or better with a flammability rating of at least VW-1.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 2 Installing the MultiLoad II Div2 15

    Figure 2.2 MultiLoad II AC Power Supply/Comm Board

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 2 Installing the MultiLoad II Div2 16

    A plastic flap has been installed over TB1 and along the right edge of the enclosure. All services loops or excess AC wiring should be placed under the partition. This includes AC wiring attached to TB1 of the optional I/O board. The figures below illustrate how to gain access to the terminal blocks, and replace the partitions so that wires containing Hazardous voltages are separated from all low voltage circuits (including field wired circuits).

    .

    Figure 2.3 AC Supply Terminal Block Access

    Figure 2.4 Removal of AC Wiring Side Partition

    Figure 2.5 Replacement of AC Wiring Side Partition

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • 17

    2.4.2 DC POWER (OPTION):

    The MultiLoad II is optionally available with a 24 Vdc power supply. The supply should be protected by a 1.5 Amp fuse.

    Power required: 18 36 Vdc, 600mA. The 3 position terminal block is located in the right hand corner of the power supply/communication board.

    !

    !

    Figure 2.6 DC Power Connections

    Wiring guidelines for using 24 Vdc power supply:

    Wire gauge (AWG) Distance (feet)

    24 50

    22 100

    20 150

    18 250

    16 400

    2.4.3 EQUIPMENT GROUNDING:

    A safety ground should be attached to terminal block TB1 (on both ac and dc input power models) to maintain electrical safety in the event of a fault condition. Follow the terminal block wiring instructions in section 2.3.

    Note that the external ground connection is not provided for the attachment of the protective conductor (the safety ground). Rather, it is provided only as a supplemental bonding connection where local authorities permit or require such a connection, for example, as a means of equipotentiality. The wire connection is on the bottom right exterior surface. The following wire sizes may be used: 10 AWG (5.26 mm2) or 11 AWG (4.17 mm2).

    Do not connect the power supply dc common to earth ground.

    2.4.4 CABLE GLAND ENTRIES:

    Five M20 x 1.5 mm apertures in the enclosure bottom are provided for the installation of cable glands. A gland with the correct corresponding thread must be installed in the opening.

    WARNING: If there are unused holes, blanking elements satisfying the flameproof d method of protection must be used. Blanking elements must be removable with the aide of a tool, ATEX certified, suitable for Gas Group IIB and suitable for an ambient temperature range of -40 C to +60 C.

  • Chapter 3 Data Communications Interface 18

    CHAPTER 3 DATA COMMUNICATIONS INTERFACE

    The MultiLoad II has four communications ports (see figure 2.1) each with a specific purpose. The following section provides the information required to select and make the wiring connections to the ports.

    Communication Port Interface Type Typical Function Terminal (Figure 2.1)

    Comm. Port 0 RS-485 Internal I/O board / FCM I / FCM II / PCM Communication

    TB2

    Comm. Port 1 RS-232 or RS-485 Host Communication (TMS)

    TB3 RS-232

    TB4 RS-485

    Comm. Port 2 RS-232 Ticket Printer/Data Logger

    TB5

    Ethernet 10/100MBPS Host Communication (TMS)

    J3 Internal

    Cat 5 Cable

    2 If service loop is used, maximum wire length in service loop not to exceed 3 inches.. 2 Separate AC and DC wiring by at least 3 inches. Do not allow excess wire in service loop to overhang printed circuit board.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 3 Data Communications Interface 19

    3.1 COMMUNICATIONS PROTOCOL SELECTION AND CONNECTION:

    3.1.1 RS-422/485:

    RS-422/485 communications protocol is designed for multi-point (i.e. computer to multiple devices, also called multi-dropped) communications up to 4,000 feet (1,220 Meters).

    RS-422 requires 4-wires (2 twisted pair) for full duplex communications and utilizes a transmit pair of wires (TDA & TDB) and a receive pair of wires (RDA & RDB).

    RS-485 requires 2-wires (1 twisted pair) for half duplex communications and utilizes a single pair of wires (TDA/RDA & TDB/RDB) for transmit and receive.

    This manual will typically refer to both RS-422 and RS-485 as simply RS485 2 wire or RS485 4 wire.

    A ground wire is not required, though some devices may have a terminal block for a ground.

    Wire used must meet the following:

    24 AWG stranded.

    4-wire, two twisted pair with overall shield.

    2-wire, one twisted pair with overall shield.

    30 pF maximum between conductors.

    1,000 ohm impedance.

    Maximum length: 4,000 feet (1,220 Meters)

    Maximum stub length: 15 feet.

    All exposed shields must be properly insulated to prevent short circuits.

    All shields must be continuous, soldered and properly insulated.

    3.1.2 RS-232

    RS-232 protocol is designed for point-to-point (i.e., computer to a single device) communications limited to 50 feet requiring a minimum of 3 wires transmit, receive and ground. Additional wires are required for hardware handshaking when using printers and data loggers.

    Wire used must meet the following:

    24 AWG.

    3 conductor with overall shield (data only) or 8 conductor with overall shield (full handshaking).

    30 pF maximum between conductors.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 3 Data Communications Interface 20

    3.1.3 HOST/TMS COMMUNICATIONS (COM 1 - RS-485 4-WIRE)

    The Host/TMS Computer System can be connected to the MultiLoad II via RS485 4-wire on COM 1.

    The TD and RD pairs are swapped at the Host/TMS.

    Figure 3.1 RS485 4-Wire, Host to a Single MultiLoad II (recommended)

    Figure 3.2 RS485 4-Wire, Host to Multiple MultiLoad IIs

    Host/TMS RS485

    MultiLoad II COM 1

    TDA RDATDB RDBRDA TDARDB TDB

    Host/TMS RS485

    MultiLoad II #1 COM 1

    MultiLoad II #n COM 1

    TDA RDA RDATDB RDB RDBRDA TDA TDARDB TDB TDB

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 3 Data Communications Interface 21

    3.1.4 HOST/TMS COMMUNICATIONS (COM 1 - RS-485 2-WIRE)

    The Host/TMS Computer System can be connected to the MultiLoad II via RS485 2-wire on COM 1.

    The TD and RD pairs tied together at the Host/TMS and all MultiLoad IIs.

    Figure 3.3 RS485 2-Wire, Host to a Single MultiLoad II

    Figure 3.4 RS485 4-Wire, Host to Multiple MultiLoad IIs

    TDA TDB

    RDARDB

    RDA RDB

    TDATDB

    MultiLoad II #1 COM 1

    Host/TMS RS485

    RDARDBTDATDB

    MultiLoad II #n COM 1

    MultiLoad II COM 1

    TDA RDATDB RDBRDA TDARDB TDB

    Host/TMS RS485

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 3 Data Communications Interface 22

    3.1.5 HOST/TMS COMMUNICATIONS (COM 1 - RS-232)

    The Host/TMS Computer System can be connected to the MultiLoad II via RS232 on COM 1.

    The TX and RX are swapped at the Host/TMS.

    MultiLoad II has the ability to multi-drop onto a RS232 line.

    Figure 3.5 RS232, Host to a Single MultiLoad II

    Host/TMS RS232

    MultiLoad II COM 1

    TX RX

    RXTX

    GND GND

    TX RX

    RXTX

    GND GND

    MultiLoad II #1 COM 1

    Host/TMS RS232

    RXTXGND

    MultiLoad II #n COM 1

    Figure 3.6 RS232, Host to Multiple MultiLoad IIs

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 3 Data Communications Interface 23

    3.1.6 HOST TICKET PRINTER/DATA LOGGER (COM 2 - RS-232)

    A Ticket Printer or Data Logger can be connected to the MultiLoad II via RS232 on COM 2.

    The TX and RX are swapped at the MultiLoad II.

    Handshake lines MUST be connected or terminated or a Printer Error will be reported.

    MultiLoad II will monitor CTS, DSR and DCD for active signals.

    Figure 3.7 Ticket Printer / Data Logger Connections with Handshake

    MultiLoad II COM 2

    Printer Logger RS232 DB25 Connector

    RX CTS TX

    GND DSR DCD RTS DTR

    7 GND 4 RTS 5 CTS 6 DSR 8 - DCD

    8 - DCD

    2 - TX 20 - DTR

    3 - RX

    5 CTS 6 DSR

    4 RTS

    3 - RX 7 GND

    20 - DTR 2 - TX

    DTR RTS DCD DSR GND TX

    CTS RX

    Printer Logger RS232 DB25 Connector

    MultiLoad II COM 2

    Figure 3.8 Ticket Printer / Data Logger Connections without Handshake

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 3 Data Communications Interface 24

    3.1.7 ETHERNET

    Ethernet wiring standard T568B - Cat5 cable (or greater).

    Figure 3.10 illustrates the required connections for Ethernet.

    1 White/org 1

    7 White/Brown

    6 Green

    5 White/Blue

    4 Blue

    3 White/Grn

    2 Org

    8 Brown

    6

    7

    8

    5

    4

    3

    2

    Twisted Pairs

    Figure 3.9 Ethernet Connections

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 25

    CHAPTER 4 I/O CONFIGURATION

    4.1 CONNECTING FIELD DEVICES TO THE I/O BOARD

    The I/O board is mounted above the Power Supply/Comm board. The I/O board is connected to the Power Supply/Comm board at J4 & J5. Corresponding connections are on bottom side of the I/O board.

    Do not open enclosure unless power has been removed. !

    The following further defines Inputs and Outputs supported by the I/O board:

    5 AC Outputs: 12 - 250 Vac rms, 500 mA (Per Point), TB1

    3 DC Outputs: 0 - 30 Vdc, 600 mA (Per Point), TB3

    5 DC Inputs: 5 - 30Vdc, TB2B

    Dual Channel flow meter inputs (1-5000Hz)

    3 inputs for miscellaneous signals

    12Vdc Output: TB2A

    2W isolated Power Supply

    Power for flow meter pulsers or preamps

    RTD Input: TB4

    100-ohm platinum, four wire

    Coefficient 0.00385 Ohm/Ohm/degrees C

    Analog Input TB5

    Analog Output TB6

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 26

    Figure 4.1 Connections to I/O Board

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 27

    4.1.1 TB2A +12 VDC SUPPLY

    Terminal Block (TB2A) provides a connection point to the MultiLoad II 2W 12V isolated power supply. Use the supply to power flow meter pulse transmitters or pre-amplifiers. This source can also be used as a switching voltage to the MultiLoad II DC Inputs at TB2B, DC Outputs at TB3, and voltage source for the analog output.

    Terminal Block (TB2A) Function

    TB2A-1 through TB2A-5 +12 Vdc

    TB2A-6 through TB2A-10 DC common

    Figure 4.2 TB2A + 12 Vdc Supply Assignments

    TB2a+12 Vdc

    TB2a-1TB2a-2TB2a-3TB2a-4TB2a-5TB2a-6TB2a-7TB2a-8TB2a-9

    TB2a-10

    +12 Vdc

    DC common

    Meter Pre-Amp or Pulser

    +12 Vdc

    PowerSupply

    Figure 4.3 +12 Vdc Supply Voltage

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 28

    4.1.2 TB2B DC INPUTS

    Port Terminal Block (TB2b) Function

    TB2B-1 DC Input or Pulser V+ Port 4

    TB2B-2 DC Input or Pulser GND

    TB2B-3 DC Input or Pulser V+ Port 5

    TB2B-4 DC Input or Pulser GND

    TB2B-5 DC Input or Pulser V+ Port 6

    TB2B-6 DC Input or Pulser GND

    TB2B-7 DC Input or Pulser V+ Port 7

    TB2B-8 DC Input or Pulser GND

    TB2B-9 DC Input or Pulser V+ Port 9

    TB2B-10 DC Input or Pulser GND

    5-30 Vdc dual channel flow meter inputs 1-

    5,000 Hz

    Figure 4.4 TB2B DC Input Assignments

    TB2b-1TB2b-2TB2b-3TB2b-4TB2b-5TB2b-6TB2b-7TB2b-8TB2b-9

    TB2b-10

    TB2bDC Inputs

    Port 4

    Port 5

    Port 6

    Port 7

    Port 9

    Figure 4.5 DC Inputs

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 29

    The source voltage for the DC inputs to MultiLoad II can come from TB2a (+12 Vdc) or from an external source, not to exceed 30 Vdc.

    TB

    TB

    2

    5

    TB 2 a - 1 TB 2 a - 2 TB 2 a - 3 TB 2 a - 4 TB 2 a -TB 2 a - 6

    2 a - 7 TB 2 a - 8 TB 2 a - 9 TB 2 a - 10

    +12 Vdc

    DC common

    Meter Pre-Amp or Pulser

    +12 Vdc

    TB2b-1TB2

    Permissive

    AB

    -10bTB2-9b2TB-8b2TB

    -7b2TB-6bTB2-5bTB2-4bTB2-3bTB2-2b

    a + 12 Vdc

    TB2bDC Inputs

    Figure 4.6 Product Meter and Permissive

    TB2a+12 vdc

    TB2a-1TB2a-2TB2a-3TB2a-4TB2a-5TB2a-6TB2a-7TB2a-8TB2a-9TB2a-10

    +12 vdc

    dc commom

    Additive Meter Pre-Amp

    +12 vdc

    TB2b-1TB2b-2TB2b-3TB2b-4TB2b-5TB2b-6TB2b-7TB2b-8TB2b-9TB2b-10

    TB2bDC Inputs

    DC common

    Figure 4.7 Additive Meter

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 30

    4.1.3 TB3 DC OUTPUTS

    The source voltage for the DC Outputs to field devices can come from TB2a (+12 Vdc) or from an external source, not to exceed 30 Vdc, 1.2A

    Port Terminal Block (TB) Function

    TB3-1 V+ In Port 10

    TB3-2 V+ Out

    TB3-3 V+ In Port 11

    TB3-4 V+ Out

    TB3-5 V+ In Port 12

    TB3-6 V+ Out

    0-30 Vdc

    1,2A

    Figure 4.8 TB3 DC Outputs Assignments

    TB2a+12 Vdc

    TB2a-1TB2a-2TB2a-3TB2a-4TB2a-5TB2a-6TB2a-7TB2a-8TB2a-9

    TB2a-10

    +12 Vdc

    DC common TB3

    DC Outputs

    TB3-1TB3-2TB3-3TB3-4TB3-5TB3-6

    Pump Relay Coil

    Figure 4.9 DC Outputs

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 31

    4.1.4 TB4 RTD INPUT

    Wire a 100 ohm, four-wire, platinum RTD to TB4 as shown. The RTD must have a coefficient of 0.00385 Ohm / Ohm / C.

    Terminal Block (TB) Function

    TB4-1 V+

    TB4-2 R+

    TB4-3 R-

    TB4-4 GND

    Figure 4.10 TB4 RTD Input Assignments

    TB4RTD Input

    TB4-1TB4-2TB4-3

    TB4-4

    Four-Wire RTDPlatinum, 100 Ohm

    White V+

    White R+

    Red R-

    Red GND

    Figure 4.11 RTD Connection

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 32

    4.1.5 TB1 AC OUTPUTS

    Connect the 12-250 VAC to the even numbered terminals. Limit current to 1.25 A (rms).

    Port Terminal Block (TB1) Function

    TB1-10 Line In Port 0

    TB1-9 Line Out

    TB1-8 Line In Port 1

    TB1-7 Line Out

    TB1-6 Line In Port 2

    TB1-5 Line Out

    TB1-4 Line In Port 3

    TB1-3 Line Out

    TB1-2 Line In Port 8

    TB1-1 Line Out

    12-250 Vac

    1.,25A

    Figure 4.12 TB1 AC Output Assignments

    TB1-10TB1-9TB1-8TB1-7TB1-6TB1-5TB1-4TB1-3TB1-2TB1-1

    TB1AC Outputs

    L1 12- 250 VAC

    Add. Inject Solenoid

    N

    Port 1

    Port 0

    Port 2

    Port 3

    Port 8

    Add. Inject Solenoid

    N.O. Solenoid

    N.C. Solenoid

    Figure 4.13 Digital Control Valve and Additive Connections

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 33

    4.1.6 TB5-ANALOG INPUT

    Terminal Block (TB5) Function

    TB5-1 I+ Positive (higher) voltage or current

    TB5-2 I- Negative (lower) voltage or current

    Figure 4.14 TB6 Analog Current Input Assignments

    Analog current input from an analog device to TB5.

    TB5 Analog Input

    GND

    I++

    Analog Current

    TB5-1 TB5-2

    Transmitter

    Figure 4.15 Analog Current Input

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 4 I/O Configuration 34

    4.1.7 TB6-ANALOG OUTPUT

    Terminal Block (TB) Function

    TB6-1 V+ (Power)

    TB6-2 GND

    TB6-3 I Input (Current)

    TB6-4 V Input (Voltage)

    Figure 4.16 TB6 Analog Output Assignments

    Analog current output from TB6 to an analog device.

    GND

    Analog Current

    TB2A-5 TB2A-6

    TB6-1 TB6-2 TB6-3 TB6-4

    I In

    Receiver TB6 Analog Output

    Figure 4.17 Analog Current Output

    Analog voltage output from TB6 to an analog device.

    GND V In

    TB2A-5 TB2A-6

    TB6-1 TB6-2 TB6-3 TB6-4

    Analog Voltage Receiver TB6

    Analog Output

    Figure 4.18 Analog Voltage Output

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 35

    CHAPTER 5 CONFIGURATION

    5.1 NAVIGATING THE SYSTEM:

    The following describes how to navigate the system, select field values, perform data entry, and toggle options on and off.

    5.1.1 SMP KEYPAD:

    The SMP keypad has 18 keys, including numeric and function keys, used to:

    Select menu items and fields

    Enter data in fields

    Initiate actions

    Return to previous screens

    Numeric keys (1 through 9 and 0) used to enter numeric data.

    The decimal point (. ) is used to enter numeric field data with a decimal point.

    CLR key is used to clear data entered in error. The CLR key is a backspace key erasing characters as the cursor moves backward.

    5.1.2 SWITCH ACCESS CONTROL (OPTION)

    MultiLoad II supports external access control switches. These switches limit access to Program Mode and changes to Weights and Measures controlled parameters.

    There are three types of external switches and all can be sealed and/or locked to prevent access to Program Mode and prevent changes to Weights and Measures controlled parameters.

    In Program Mode the operator has access to the following:

    - The Configuration Menu parameters

    - The Diagnostics Menu and its functions

    - Other administrative procedures, such as clearing high-level alarms.

    To access Program Mode, the MultiLoad II terminal operator must:

    1. Move the Program Mode switch into the active position.

    2. At the idle card in screen, enter the security code (default security code is 000000) and press the key.

    2 Your local Weights and Measures office may need to be contacted after breaking the seal and changing parameters. This is typically done only during meter proving or temperature calibration.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 36

    5.1.3 TYPE 1 PROGRAM / W&M SWITCHES

    Type 1 switches consist of two separate external rotary switches, one for Program Mode Access, and one for W&M change access. Each switch has external fold down cover that can be locked or sealed with a wire and lead seal to prevent moving the switch into the active state. Each cover will also be stamped as W&M or Program to indicate function.

    Figure 5.1 Type 1 Program / W&M Switches

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 37

    5.1.4 TYPE 2 PROGRAM / W&M SWITCHES

    - Type 2 switches consist of a single 3-position external rotary switches, where each position corresponds to an operating mode. The switch has two external fold down covers that limits the switch rotation as described below. Each cover can be locked or sealed with a wire and lead seal to prevent moving the switch into the active states. Each cover will also be stamped as W&M or Program to indicate function.

    Figure 5.2 Type 2 Program / W&M Switches

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 38

    5.1.5 TYPE 3 PROGRAM / W&M SWITCHES

    Type 3 switches consist of two separate external magnetic bolts, one for Program Mode Access, and one for W&M change access. Program or W&M access is achieved by removing the corresponding bolt. Each bolt has a small hole that can be sealed with a wire and lead seal to detect unauthorized access. Both bolts are also have an external fold down cover that can be locked to prevent moving someone from removing either bolt. The cover will also be stamped as W&M or Program to indicate the function of each bolt.

    Figure 5.3 Type 3 Program / W&M Switches

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 39

    5.1.6 PROGRAM MODE / W&M DIP SWITCH

    Two DIP switches on the CPU board can also provide the closure of the Program Mode / W&M switch contacts. When the MultiLoad II does not have the external Program Mode / W&M switch installed, it is necessary to use this DIP switches on the CPU board to enable program mode and W&M access.

    Switches are numbered 1 through 4 with 1 being closest to the front of the enclosure (top of the picture), and 4 being toward the back of the enclosure (bottom of the picture).

    When switch is in the ON position, the switch is in the active state. A switch is ON when it moved right, and OFF when moved to the left.

    Switch #3 is the program mode switch. Switch #4 is the W&M access switch. In the Figure below, the Program Mode switch is currently Active, while the W&M Switch is not active.

    2 A switch input will be considered active with either the DIP switch OR external switch is active (ON). Your Weights and Measures inspector may wish to verify that DIP switch 4 (bottom switch) is in the off position (moved left) prior to sealing the MultiLoad II enclosure to ensure that W&M parameters are secure.

    Figure 5.4 CPU Board Program and W&M DIP Switches

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 40

    5.1.7 PROGRAM MODE / W&M FIELD SWITCHES

    The MultiLoad II also has the ability to accept field inputs for the Program Mode and W&M Access switches.

    The W&M Key FCM# and Program Key FCM# in the RCU W&M Parameters list allow any field I/O position to be the source of the switch input. See Weights and Measures for more information.

    2 If an external switch is wired to the MultiLoad II as a W&M access switch, the installer may be required to seal the switch enclosure and all conduit junction points between the switch and the MultiLoad II to ensure that the W&M parameters remain secure. Consult your local Weights and Measures for specifics.

    2 A switch input will be considered active with either the external switch OR a configured I/O point is active (ON). Your Weights and Measures inspector may wish to verify the W&M Key FCM# parameter prior to sealing the MultiLoad IIs W&M switch to ensure that W&M parameters are secure.

    - If no external field W&M switch is installed, this parameter MUST be DISABLED.

    - If an external field W&M switch is installed, this parameter MUST indicate the correct field I/O port.

    Enter Program Mode -> Weights & Measures -> RCU

    Next Prev Exit Enter

    Program Key FCM#: DISABLD W&M Key FCM#: DISABLD Measure on Load Scrn: DISABLD Min Time Change Secs: 60 Measure Used: GALLONS MM/DD/YYYY Date: ENABLED

    RCU W&M SETUP

    Operating Mode: Normal operation of the MultiLoad II. Switch can be locked or sealed in this position.

    Program Mode: Provides access to configuration parameters, diagnostic menu, administrative functions and clearing high-level alarms. Switch can be locked or sealed in this position.

    Weights and Measures Mode:

    Provides access to weight and measures parameters. Proceed to Weights and Measures section of the menu. For operation in this mode see the Weights and Measures section of the manual. Switch can be locked or sealed out of this position.

    Figure 5-5 Program and Weights and Measures Switch

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 41

    5.1.8 MENUS AND SCREENS

    The MultiLoad II SMP Main Menu is shown below. From this menu, you select one of four main functions.

    Next Prev Exit Enter

    Views and Inquiries Weights and Measures

    Configuration Diagnostics

    M A I N M E N U

    The reverse video highlight bar indicates the current selection. Press Next to select Diagnostics, and then press the Enter key to go to the Diagnostics Menu.

    Next Prev Exit Enter

    Bay Preset

    RCU

    FCM Health PCM Health

    PCM Com FCM Com Unicode Display Keypad Network Test Custom Logic Serial Ports Additives COM Loopback Components Card Reader Meters

    D I A G N O S T I C S M E N U

    For menu options and function screen items, pressing the Next key moves the selection bar down, and pressing the Prev (Previous) key moves the selection bar up.

    To return to the Main Menu, press EXIT. To return to any previous screen, press the EXIT key.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 42

    5.1.9 FIELD MODIFICATION AND DATA ENTRY

    MultiLoad II SMP will have all fields populated with default values. There are two types of fields, toggle or data entry. Toggle fields contain a number of choices. Scroll through the choices by pressing the Enter key. Data entry fields require that a value be entered into the field, within a given, applicable range. In the example below, RCU Address field is highlighted.

    Next Prev Exit Enter

    Terminal Name: Toptech Terminal Modem Login: RCUTE TOPTECH Modem Dial: Password #5: ******* Password #4: ******* Password #3: ******* Password #2: ******* Password #1: ******* Remote Processing: DISABLD RCU Address: 001

    RCU GENERAL SETUP

    Press ENTER to choose the field. A blinking cursor indicates data can be entered.

    Enter Exit

    Terminal Name: Toptech Terminal Modem Login: RCUTE TOPTECH Modem Dial: Password #5: ******* Password #4: ******* Password #3: ******* Password #2: ******* Password #1: *******

    RCU GENERAL SETUP RCU Address: Remote Processing: DISABLD

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 43

    Type in the new value (e.g. 123) and press ENTER. The new value displays on the screen.

    Enter Exit

    Terminal Name: Toptech Terminal Modem Login: RCUTE TOPTECH Modem Dial: Password #5: ******* Password #4: ******* Password #3: ******* Password #2: ******* Password #1: *******

    RCU GENERAL SETUP RCU Address: 123 Remote Processing: DISABLD

    Using this same screen as an example, the Remote Processing line is selected and ENTER is pressed, use the NEXT or PREV keys to toggle between the values ENABLED and DISABLD, as shown below. You must then press ENTER to accept the desired choice.

    Next Prev Exit Enter

    Terminal Name: Toptech Terminal Modem Login: RCUTE TOPTECH Modem Dial: Password #5: ******* Password #4: ******* Password #3: ******* Password #2: ******* Password #1: ******* Remote Processing: DISABLD RCU Address: 001

    RCU GENERAL SETUP

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 44

    5.2 SMP PRELIMINARY CONFIGURATION:

    1) Energize the SMP.

    2) When the SMP is first energized the Cardin screen appears, indicating Operating Mode.

    Press Next to Begin For Access

    3) Go to program mode by entering 00000 on the keypad, then press Next.

    If SMP has Program/Weights and Measures switch, switch must be set to Program Mode. (See Appendix Figure 6.10) 00000 is the factory default access code. See RCU General setup section for changing or adding new access codes.

    4) The program mode main menu displays:

    Next Prev Exit Enter

    Weights and Measures Views and Inquiries

    Diagnostics Configuration

    M A I N M E N U

    5) Press Enter to access the Configuration menu.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 45

    6) Press Enter to access RCU General Setup.

    7) Press Enter and key in RCU address (001) of SMP.

    The default RCU address is 001.

    RCU GENERAL SETUP RCU Address: 001 Remote Processing: DISABLD Password #1: ******* Password #2: ******* Password #3: ******* Password #4: ******* Password #5: ******* Modem Dial: Modem Login: RCUTE TOPTECH Terminal Name: Toptech Terminal

    Next Prev Exit Enter

    C O N F I G U R A T I O N M E N U Communication

    Next Prev Exit Enter

    Customer Logo Setup

    RCU Setup Equipment Setup Alarm Setup Products Additive Cal. Remote Adtv Cal. Access ID's Custom Logic

    RCU General Setup Network

    8) Press Exit to return to the Configuration Menu.

    9) Select and press Enter to return to the Main Menu.

    10) If SMP has Program/Weights and Measures switch return switch to Operating Mode.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 46

    5.3 VERIFY COMMUNICATIONS BETWEEN SMP AND I/O BOARD:

    Enter program mode by pressing 00000 on the keypad, then press Next key.

    Select diagnostics from main menu.

    Next Prev Exit Enter

    Preset Bay RCU PCM Health FCM Health PCM Com FCM Com Unicode Display Keypad Network Test Custom Logic Serial Ports Additives COM Loopback Components Card Reader Meters

    D I A G N O S T I C S M E N U

    Select FCM COM

    Exit

    00-Ok 004 FCM COM DIAGNOSTICS

    If screen display is the same as above, the I/O board is communicating with the SMP.

    If I/O board is not communicating the message 00-ERR appears.

    If 00-ERR appears see I/O board diagnostics.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 47

    CHAPTER 6 SERVICE AND REPAIR

    6.1.1 MODULAR DESIGN:

    The MultiLoad II SMP has been constructed with replaceable modules or sub-assemblies that are available from Toptech (see Appendix for part numbers). These include:

    CPU Subassembly (CPU Chassis, CPU Board, Power Supply / COM Board, I/O Board).

    Display Subassembly (Active Matrix Display and Display Board)

    Keypad

    Keypad Barrier Circuit

    The following sections describe how to remove and replace each subassembly and where possible, how to further disassemble the subassembly

    NOTE: Do not service MultiLoad II without removing mains power.

    NOTE: Do not open the MultiLoad II enclosure while the MultiLoad II is energized.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 48

    6.1.2 OPERATING THE FLAT DISPLAY CABLE CONNECTORS:

    Removal:

    1. To remove the Display Cable rotate the cam to the open (up) position. (See Figure 5.2.)

    2. Gently pull the cable straight out free of the connector.

    Installation:

    1. To install the display cable make sure the cam is in the open (up) position.

    2. Gently insert the cable with the dark insulated side towards the cam. (See Figure 5.3.) When inserting the cable make sure that it is not tilted to one side or the other and that the bottom of the cable is completely seating in the connector.

    3. Rotate the cam to the closed (down) position to lock in place. (See Figure 5.4.)

    Figure 6.1 Cam lock in the Open (Up) position

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 49

    Figure 6.2 Display Cable Insertion

    Figure 6.3 Cam lock in the closed (down) position

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 50

    6.1.3 CPU SUBASSEMBLY REMOVAL AND REPLACEMENT:

    NOTE: Using a magnetic screwdriver is very helpful in retaining the screws during removal and installation.

    Removal:

    1. Disconnect all field wiring from the I/O board.

    2. Disconnect all Serial Communications from the Power Supply/COM board.

    3. Disconnect Mains Power from the Power Supply/COM board.

    4. Disconnect the flat display cable (after releasing the cam lock) and display power cable.

    5. Disconnect the W&M Access/Program Mode switch cable from the CPU board.

    6. Remove the four chassis mounting screws (not the mounting screws for the I/O board or Power Supply / COM board.

    7. Carefully remove the CPU chassis from inside the base by removing the CPU board side of the chassis first.

    Installation:

    1. Carefully insert the CPU chassis back into the enclosure.

    2. Install the chassis mounding screws.

    3. Connect the W&M Access/Program Mode switch cable to the CPU board.

    4. Reconnect the display power cable and the flat display cable (remember to secure the cam lock).

    5. Connect the Mains Power to the Power Supply/COM board.

    6. Connect all Serial Communications to the Power Supply/COM board.

    7. Connect all field wiring to the I/O board.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 6 Service and Repair 51

    6.1.4 DISPLAY SUBASSEMBLY REMOVAL AND REPLACEMENT:

    Removal:

    1. Disconnect the flat display cable (after releasing the cam lock), display power cable and the keypad cable.

    2. While supporting the display subassembly, remove the four mounting screws.

    3. Do not attempt to disassemble the display subassembly. Return entire subassembly to Toptech for repair after receiving an RMA number.

    Installation:

    1. While supporting the display subassembly, install the four mounting screws.

    2. Connect the keypad cable, display power cable and the flat display cable.

    3. Verify routing and clearance of the cable

    6.1.5 KEYPAD REMOVAL AND REPLACEMENT:

    Removal:

    1. Using a security screwdriver bit (available from Toptech), remove all security screws holding on the Keypad bezel.

    2. Remove the bezel.

    3. Using a flat screwdriver, carefully pry out the keypad.

    4. Disconnect the keypad cable from the back of the keypad.

    Installation:

    1. Connect the keypad cable to the back of the keypad.

    2. Carefully install the keypad into the cover.

    3. Install the keypad bezel.

    4. Using a security screwdriver bit, install all the bezel holding security screws.

    6.1.6 KEYPAD BARRIER CIRCUIT REMOVAL AND REPLACEMENT:

    Removal:

    1. Disconnect the keypad cable from the display subassembly.

    2. Remove the four screws holding barrier circuit box.

    3. One by one, move over the keypad wires to a new barrier circuit.

    Installation:

    1. Reinstall the barrier circuit box with the three holding screws.

    2. Connect the keypad cable to the display subassembly.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 7 - Appendix 52

    CHAPTER 7 APPENDIX

    Figure 7.1 Unit Outline Drawing Front View

    Figure 7.2 Unit Outline Drawing Bottom View

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 7 - Appendix 53

    Figure 7.3 Unit Outline Drawing Side View

    Figure 7.4 Replacement Parts SMP Base Drawing

    NOTE: TT PN = Toptech Part Number.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 7 - Appendix 54

    Figure 7.5 Exploded view front panel assembly

    Figure 7.6 Microprocessor Board

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 7 - Appendix 55

    Figure 7.7 Power Supply Board

    Figure 7.8 I/O Board.

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

  • Chapter 7 - Appendix 56

    Figure 7.9 Power Supply / Comm Board & I/O Board Chassis

    MultiLoad II Single Meter Preset (SMP) Installation Guide: Version 1.2 - Part # 6067

    Electrical Considerations and Regulatory RequirementsChapter 1 General1.1 Product Specification MultiLoad II SMP:1.1.1 Local (stand-alone) Mode1.1.2 Remote Processing ModeOptions:

    1.2 Information Alerts:1.2.1 Typographical Conventions:1.2.2 Receiving and/or Returning Equipment:

    1.3 Electrostatic Discharge (ESD) Protection:

    Chapter 2 Installing the SMP2.1 Tools Required2.1.1 Installation2.1.2 Servicing and Repair

    2.2 Mounting SMP Enclosure:2.2.1 Metal Plate or Rail:2.2.2 Wood:2.2.3 Concrete or Cinder Block:

    2.3 Recommended Wire Sizes And Torque For All Terminal Blocks2.4 Electrical Supply Connections2.4.1 AC Power:2.4.2 DC Power (option):2.4.3 Equipment Grounding:2.4.4 Cable Gland Entries:

    Chapter 3 Data Communications Interface3.1 Communications Protocol Selection and Connection:3.1.1 RS-422/485:3.1.2 RS-2323.1.3 Host/TMS Communications (COM 1 - RS-485 4-wire)3.1.4 Host/TMS Communications (COM 1 - RS-485 2-wire)3.1.5 Host/TMS Communications (COM 1 - RS-232)3.1.6 Host Ticket Printer/Data Logger (COM 2 - RS-232)3.1.7 Ethernet

    Chapter 4 I/O Configuration4.1 Connecting Field Devices to the I/O Board4.1.1 TB2A +12 Vdc Supply4.1.2 TB2B DC Inputs4.1.3 TB3 DC Outputs4.1.4 TB4 RTD Input4.1.5 TB1 AC Outputs4.1.6 TB5-Analog Input4.1.7 TB6-Analog Output

    Chapter 5 Configuration5.1 Navigating the System:5.1.1 SMP Keypad:5.1.2 Switch Access Control (Option)5.1.3 Type 1 Program / W&M switches5.1.4 Type 2 Program / W&M switches5.1.5 Type 3 Program / W&M switches5.1.6 Program Mode / W&M DIP Switch5.1.7 Program Mode / W&M Field Switches5.1.8 Menus and Screens5.1.9 Field Modification and Data Entry

    5.2 SMP Preliminary Configuration:5.3 Verify Communications Between SMP And I/O Board:

    Chapter 6 Service and Repair6.1.1 Modular Design:6.1.2 Operating the Flat Display Cable Connectors:6.1.3 CPU Subassembly Removal and Replacement:6.1.4 Display Subassembly Removal and Replacement:6.1.5 Keypad Removal and Replacement:6.1.6 Keypad Barrier Circuit Removal and Replacement:

    Chapter 7 Appendix