Product Specification 03248E MFR 2 Multi Function Relay Mains & Generator Protection & Control Generator and mains protection Synchronization for two breakers Frequency and voltage matching Real power control Power factor control Load/var sharing Counters for kWh, operating hours, maintenance call Programmable relay outputs PC and front panel configurable CAN bus based communication Microprocessor technology for flexible and reliable operation CE marked UL/cUL Listed APPLICATIONS Based on micro-controller technology, Woodward's MFR 2 Multi Function Relay incorporates functions and features for multiple applications (e.g. gensets, hydropower, etc.) in isolated or parallel utility operation. The MFR 2 is designed for generators and switchgear equipment that require independent protection. The ability for the MFR 2 to quickly decouple from the mains when working in parallel with the mains gives complete generator protection for frequency, voltage, and real and re- active power control allowing load/var sharing between as many as eight units. DESCRIPTION The Series of MFR 2 Multi Function Relays consists of the model MFR 2S/PSVA . Features Battery voltage monitoring kWh/oper.hours/start/maintenance counter 4 configurable discrete alarm inputs 4 configurable relays Two-line LC display Synchroscope Multi level password protection Configuration directly or via PC CAN bus communication DESCRIPTION (continued) Protection ANSI # Mains Over-/undervoltage (59/27) Over-/underfrequency (81O/U) Voltage asymmetry (47) Phase/vector shift (MFR 2S only) (78) Generator Over-/undervoltage (59/27) Over-/underfrequency (81O/U) Overload (32) Reverse/reduced power (32R/F) Unbalanced load (46) Re-active power monitoring Loss of excitation (40Q) Time-overcurrent (50) Controller Synchronizer for 2 CB Discrete raise/lower for n/f/V/P/Q Speed/frequency/real power Voltage/power factor Isolated operation Mains parallel operation Load/var sharing (up to 8 units) (MFR 2S only) Dead bus operation MFR 2S/PSVA The PSVA package additionally includes: df/dt (ROCOF) (81RL) 2 conf. analog outputs (20 mA) 2 conf. pulse outp. for kWh/kvarh Real power set-point input (20 mA)

Transcript of Multi Function Relay - JEWON ENGjewoneng.co.kr/Services/Products/PDF/Power-Management/... · 2013....

Page 1: Multi Function Relay - JEWON ENGjewoneng.co.kr/Services/Products/PDF/Power-Management/... · 2013. 6. 18. · DIN rail mount option (please order brackets P/N 8923-1023) 8 116 50

Product Specification 03248E

MFR 2 Multi Function Relay

Mains & Generator Protection & Control

· Generator and mains protection

· Synchronization for two breakers

· Frequency and voltage matching

· Real power control

· Power factor control

· Load/var sharing

· Counters for kWh, operating hours, maintenance call

· Programmable relay outputs

· PC and front panel configurable

· CAN bus based communication

· Microprocessor technology for flexible and reliable operation

· CE marked

· UL/cUL Listed

APPLICATIONS

Based on micro-controller technology, Woodward's MFR 2 Multi Function Relay incorporates functions and features for multiple applications (e.g. gensets, hydropower, etc.) in isolated or parallel utility operation. The MFR 2 is designed for generators and switchgear equipment that require independent protection. The ability for the MFR 2 to quickly decouple from the mains when working in parallel with the mains gives complete generator protection for frequency, voltage, and real and re-active power control allowing load/var sharing between as many as eight units.

DESCRIPTION

The Series of MFR 2 Multi Function Relays consists of the model MFR 2S/PSVA.

Features · Battery voltage monitoring · kWh/oper.hours/start/maintenance

counter · 4 configurable discrete alarm inputs · 4 configurable relays · Two-line LC display · Synchroscope · Multi level password protection · Configuration directly or via PC · CAN bus communication

DESCRIPTION (continued)

Protection ANSI # Mains · Over-/undervoltage (59/27) · Over-/underfrequency (81O/U) · Voltage asymmetry (47) · Phase/vector shift (MFR 2S only) (78) Generator · Over-/undervoltage (59/27) · Over-/underfrequency (81O/U) · Overload (32) · Reverse/reduced power (32R/F) · Unbalanced load (46) · Re-active power monitoring · Loss of excitation (40Q) · Time-overcurrent (50)

Controller · Synchronizer for 2 CB · Discrete raise/lower for n/f/V/P/Q · Speed/frequency/real power · Voltage/power factor · Isolated operation · Mains parallel operation · Load/var sharing (up to 8 units) (MFR 2S only) · Dead bus operation

MFR 2S/PSVA The PSVA package additionally includes: · df/dt (ROCOF) (81RL) · 2 conf. analog outputs (20 mA) · 2 conf. pulse outp. for kWh/kvarh · Real power set-point input (20 mA)

Page 2: Multi Function Relay - JEWON ENGjewoneng.co.kr/Services/Products/PDF/Power-Management/... · 2013. 6. 18. · DIN rail mount option (please order brackets P/N 8923-1023) 8 116 50

SPECIFICATIONS

Accuracy .......................................................................................... Class 1 Power supply ..................................................................... 24 Vdc (+/-30 %) Intrinsic consumption .................................................................. max. 15 W Ambient temperature ................................................................ -20 to 70 °C Ambient humidity ...................................................... 95 %, non-condensing Voltage ........... Rated value /D: [1] 66/115 Vac or [4] 230/400 Vac Maximum value (Vmax): [1] 150 Vac or [4] 300 Vac Rated voltage Vph-ground: [1] 150 Vac or [4] 300 Vac Rated surge voltage: [1] 2.5 kV or [4] 4.0 kV Measuring frequency ................................................ 50/60 Hz (40 to 70 Hz) Linear measuring range up to ....................................................... 1.3×Vrated Input resistance ..................................................... [1] 0.21 MW, [4] 0.7 MW Max. power consumption per path ................................................... 0.15 W Current (Irated) .............................................................. [1] ../1 A or [5] ../5 A Linear measuring range up to ............................................... Igen = 3.0×Irated Imains = 1.5×Irated Load ............................................................................................. < 0.15 VA Rated short-time current (1 s) ................................. [1] 50×Irated, [5] 10×Irated Discrete inputs .............................................................................. isolated Input range .................................................................... 18 to 250 Vac or dc Input resistance ..................................................................... approx. 68 kW

Pulse outputs ................................................................... transistor output Rated gate voltage ............................................................................ 24 Vdc Maximum gate voltage ...................................................................... 32 Vdc Minimum gate current .................................................................... 10 mAdc Maximum gate current ................................................... 30 mAdc (0.5 Vdc) Relay outputs ................................................................................ isolated Contact material ............................................................................... AgCdO Load (GP) ................................................. 24 Vdc@2 Adc, 250 Vac@2 Aac Pilot duty (PD) ...................................................................... 24 Vdc@1 Adc Analog output ................................................................................ isolated Type ............................................................. 0/4 to 20 mA, freely scaleable Resolution .................................................... 8/12 Bit (depending on model) Max. load 0/4 to 20 mA ..................................................................... 500 W Insulating voltage ......................................................................... 3,000 Vdc Housing ...................................................... Type APRANORM DIN 43 700 Dimensions ....................................................................... 144×72×122 mm Front cutout ............................................................................... 138×67 mm Connection ................................................ screw/plug terminals depending on connector 1.5 mm² or 2.5 mm² Front ................................................................................. insulating surface Protection system ................................................................................ IP 21 Weight ............................................ depending on version, approx. 1,000 g Disturbance test (CE) .................................................. tested according to applicable EN guidelines Listings ............................................... UL/cUL listed for ordinary locations

DIMENSIONS

Bottom view

72

DIN rail mountoption (please order

brackets P/N 8923-1023)

8

116 50

139

179

65

2735

Back view withconnecting terminals

Front view

X1 X5

6570 6075 5450

0 24

48 25

2004-11-11 | MFR 2 Dimensions r2ww-4604-ab.skf

144

80 87

Configuration portConfiguration port

Page 3: Multi Function Relay - JEWON ENGjewoneng.co.kr/Services/Products/PDF/Power-Management/... · 2013. 6. 18. · DIN rail mount option (please order brackets P/N 8923-1023) 8 116 50

WIRING DIAGRAM (MFR 2S/PSVA; refer to manual for other units)

Drive raise

lower109

80 V

I A

Analog output0/4 to 20 mA

7071

72

Subject to technical modifications.

G

s2 (l)25

s1 (k)

s2 (l)

s1 (k)2629

3020

s1 (k)

s2 (l)3132

2122

Alarm input 2 62

N

0 Vdc

24 Vdc

Switching set point 1 <---> 2

Enable GCB

0

2005-09-13 | MFR 2 Wiring Diagram r2ww-0537-ap.skf

21

35

Isolated operation ON

Common

Common (terminal 3/4/5/6/53/54)

Release monitoring

Not used

External acknowledgment352

336

734

Alarm input 1

Blocking of mains protection 4

3 3660

61

Relay 3

Ready for operation

Relay 4

Common

Alarm input 4

Alarm input 3

1863

6465

1937

3843

Relay 1

Relay 2

4644

4547

48

8081

8283 0 V

I A

Analog output0/4 to 20 mA

8485 Impulse output kvarh

Open Collector

8687 Impulse output kWh

Open Collector

1

Analog input0/4 to 20 mA- Setpoint value: Real power kW

X1X2

X3X4

X5

InterfaceCAN bus

PSVA

Generator current L1

Generator current L2

Generator current L3

SPEED / POWERThree-position controller

PSVA

Battery#2

#2Battery

#1NO/NC

#1NO/NC

#2Battery

#1NO/NC

#1NO/NC

#1NO/NC

#1NO/NC

#1NO/NC

conf

igura

ble d

uring

setu

p (N

O/NC

)#1

Batte

ry o

r ano

ther

pow

er su

pply;

term

inal 7

/33/

65 is

pos

. or n

eg. s

ignal

#2

The

sock

et fo

r the

PC

conf

igura

tion

is sit

uate

d on

the

side

of th

e un

it. Th

is is

wher

e th

e DP

C ha

s to

be p

lugge

d in.

up to

7 a

dditio

nal g

ener

ator

s(e

ach

via o

ne M

FR2)

GATE

WAY

GW 4

Cont

rol r

oom

SPS

PC

GND

CAN-H

CAN-L

Termination

5

6

7

8

MFR

2S/P

SVA

(Mult

i Fun

ction

Rela

y)

41

MCB

33

5052

51

s2 (l)

s1 (k)

2728

Mains voltage L1

Mains voltage L2

Mains voltage L3

5339

1640

1754

Enable MCB

Command: open MCB

Command: close MCB

Busbar voltage

Reply: MCB is open

GCB

3

4214

154 Reply: GCB is open

Command: close GCB

Command: open GCB

raise

lower

1112

13

Generator voltage L1

Generator voltage L2

Generator voltage L3

Mains current L1

VOLTAGE / POW.FACTThree-position controller

2324 L2

L1

Page 4: Multi Function Relay - JEWON ENGjewoneng.co.kr/Services/Products/PDF/Power-Management/... · 2013. 6. 18. · DIN rail mount option (please order brackets P/N 8923-1023) 8 116 50

International Woodward PO Box 1519 Fort Collins CO, USA 80522-1519 1000 East Drake Road Fort Collins CO 80525 Ph: +1 (970) 498-3634 Fax: +1 (970) 498-3058 email: [email protected] Europe Woodward GmbH Handwerkstrasse 29 70565 Stuttgart, Germany Ph: +49 (0) 711 789 54-510 Fax: +49 (0) 711 789 54-101 email: [email protected] Distributors & Service Woodward has an international network of distributors and service facilities. For your nearest representative, call the Fort Collins plant or see the Worldwide Directory on our website. Corporate Headquarters Rockford IL, USA Ph: +1 (815) 877-7441 www.woodward.com Subject to technical modifications. This document is distributed for informational purposes only. It is not to be construed as creating or becoming part of any Woodward Governor Company contractual or warranty obligation unless expressly stated in a written sales contract. We appreciate your comments about the content of our publications. Please send comments including the document number below to [email protected] © Woodward Governor

Company All Rights Reserved

03248E - 12/6/S

TYPICAL APPLICATIONS

52

52

MFR 2

CAN

RS232

0/4..20mA

I / O

G

81RL

78

90

79

47

81U

81O

59

27

25

25

27

59

81O50

79

32 81U

32R

32F

40Q

4639

38

12

49 55

90

74

MFR 2S

ANSI

PSVA

Control Breaker 2 Synchronization 25 ü Isolated single-unit operation ü Mains parallel operation ü Accessories kWh counter ü kvarh counter ü Operat. hours/start/mainten. counter ü Configuration via PC #1 ü Protection Gen.: Over-/undervoltage 59/27 ü Mains: over-/undervoltage 59/27 ü Gen.: Over-/underfrequency 81O/U ü Mains: over-/underfrequency 81O/U ü Mains: Voltage asymmetry 47 ü Mains: phase/vector shift 78 ü Mains: df/dt (ROCOF) 81RL ü Gen.: Overload 32 ü Gen.: Reverse power 32R ü Gen.: Reduced power 32F/37 ü Gen.: Unbalanced load 46 ü Gen.: Re-active power ü Gen.: Loss of excitation 40Q ü Gen.: Time-overcurrent 50/51* ü Controller Discrete raise/lower: n/f & P ü Discrete raise/lower: V & Q ü Active power setp.: 0/4 to 20 mA ü Load/var sharing ü I/O's Discrete alarm inputs (config.) 4 Relay outputs (config.) 74 4 Analog inputs 0/4 to 20 mA (conf.) 2 Analog outp. 0/4 to 20 mA (conf.) 2 Impulse output for kWh/kvarh ü CAN bus communication #2 ü Listings/Approvals UL/cUL listed ü Product Number P/N Language

Measuring inputs 100 Vac, ../5 A English 8440-1287 German 8440-1733

Measuring inputs 400 Vac, ../5 A English 8440-1735 German 8440-1323

* not according to ANSI guidelines (two-step protection instead of inverse time characteristic) #1 Cable incl. software necessary (DPC, Product Number P/N 5417-557) #2 Remote monitoring, control, configuration (GW 4 could be used for several interfaces)

For m

ore

info

rmat

ion

cont

act: