MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

32
MTR SHATIN TO CENTRAL LINK CONTRACT 1128 SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Transcript of MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Page 1: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Page 2: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Site Description

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Building Civil

Page 3: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

East SCL Tunnels

West SCL Tunnels

Fenwick Pier Emergency

Egress Point

South Ventilation Building &

POC

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Exclude Exhibition

Station

Page 4: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Site DescriptionThe main scope of the project: • Shatin to Central Link Tunnels by TBM • the Fenwick Pier Emergency Egress Point (FPP)• the South Ventilation Building (SOV)• Re-provisioning of POC

TBM Tunnels & FPP SOV & POC

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Page 5: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Eastern & Western SCL Tunnels (Finished)

Fenwick Pier Emergency Egress Point (ABWF Works)

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Site Progress

South Ventilation Building & Re-provisioning of POC(Under Construction)

Page 6: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Working at Height Control Hierarchy

Design for Safety

Engineering Control

Safety Promotion

Page 7: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Strut Free TBM Launching ShaftTraditional Launching Shaft

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Welding at Height

Page 8: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Strut Free TBM Launching ShaftConstruct First Dual Circular Shaft in Hong Kong

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

2 Concrete Beams to support

Page 9: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Remote machinery for D-Wall Opening

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Concrete Breaker Coring & Wire Cutting

Using

Before

Open by Wire Cut

Page 10: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Remote machinery for D-Wall Opening

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Review method for large opening Using Brokk

Page 11: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Remote machinery for D-Wall Opening

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Down Track Tunnel Opening

Up Track Tunnel Opening

Potential fall from height risk if break by hand

Utilize small size Brokk to break

Foresee potential fall from height risk

Page 12: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Traditional Bored Pile Concreting method

Remote Bucket for Bored Pile Concreting

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Page 13: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Bored Pile Concreting Alternative MethodRemote Bucket for Bored Pile Concreting

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Control

Real time monitoring

Page 14: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Traditional formwork cannot fulfill our requirement

Using PERI UP Formwork & Scaffolding System

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Low Stability, non Standardize

Cannot Deploy Precast Structure

Page 15: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Advantages of using PERI Up Formwork & Scaffold

Using PERI UP Formwork & Scaffolding System

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Self securing ledger connection

Universally Applicable

Page 16: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Extension pole for face marking in tunnel

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Page 17: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Extension pole for face marking in tunnel

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Challenging - Restricted environment

Highly commended in client’s innovation award

Page 18: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Elevated Guardrail

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Commended by Client

Pre-installed guardrail

Page 19: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Develop Simplified Safe Working Procedure

Standardize Working Procedure

Page 20: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Develop Simplified Safe Working Procedure

• Scaffold Erection / Dismantle SSWP

• Half-Landing Scaffold Erection SSWP

• Using Safety Harness SSWP

Page 21: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

Half Landing Erection Method

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Develop Simplified Safe Working Procedure

Provide temporary half-landing

Stand on half-landing to erect guardrail

Remove the temporary -landing and erect the 2nd level planking

Provide toe-board

Page 22: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Develop Simplified Safe Working Procedure

Briefing to related parties

Page 23: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

VR Work at Height Training Sessions

• Induction Training • Worker Safety Meeting

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Work at Height VR Training

Page 24: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Safety Day

Safety Day On 21 Nov 2019 Focus on major risk: including WAH

Page 25: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Safety Information Day

Sharing safety Innovative measures

Page 26: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

WAH Promotion Slogan

Working at height safety Everyone duties vigilance

Page 27: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

12 Health & Safety Basic

Page 28: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

12 Health & Safety Basic

Display Banner on site

Briefing to all site workers Distribute leaflet on site

Page 29: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

CIC Outreach Service

Page 30: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Work at Height Promotion Video

Page 31: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS

Question建造圖中的雙圓(花生)型豎井能減少大量高空工作

而本工地的雙圓(花生)豎井為香港第幾次建造呢?

A. 首次

B. 第二次

C. 第五次

Page 32: MTR SHATIN TO CENTRAL LINK CONTRACT 1128 ... - SAFETY …

MTR SHATIN TO CENTRAL LINK CONTRACT 1128SOUTH VENTILATION BUILDING TO ADMIRALTY TUNNELS