Transcript of Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.
LuxLuxProThermostats
Mt. Laurel, NJ
NEW MULTI-STAGEMULTI-STAGE
TOUCHSCREENS
Features & Programming
LuxLuxProThermostats
Mt. Laurel, NJ
• PSPU721T – 2H/1C• PSPU732T – 3H/2C• 7 Day Programmable OR
Non Programmable (Simple Mode)• Dual Fuel Capable w/optional
Outdoor Wireless Remote Temp Transmitter.
• Manual or Auto Humidity and De-Humidity Control (PSPU732T only)
• Installer Message• Energy Watch – Calculates Usage
and Dollar Amount.• Screen Lockout• Much, Much, Much More…..
NEW MULTI-STAGE
TOUCHSCREENS
VERY COMPETITIVE PRICING
LuxLuxProThermostats
Mt. Laurel, NJ
NEW TOUCHSCREENFEATURES/PROGRAMMING
• On power up, to use the PSPU721 or 732 as a simple non programmable thermostat, touch the screen.
• To switch from programmable mode to simple mode, remove the faceplate, press & release the reset button on the bottom right. When “Touch For Simple Thermostat” comes up on the screen touch the screen and the t-stat will switch to “Simple” mode.
TOUCH
FOR SIMPLE
THERMOSTAT
LuxLuxProThermostats
Mt. Laurel, NJ
• Simple Mode puts the thermostat into non programmable mode where only temperature set point, cool/heat/auto mode, or fan operation can be changed.
AUTO
FAN AUTO 72F
72.0 +-
46%
NEW TOUCHSCREENFEATURES/PROGRAMMING
LuxLuxProThermostats
Mt. Laurel, NJ
• For Programmable Mode, touch the screen. Now you can use all of the extensive programmable features to configure the thermostat the way you or the consumer wants it.
NEW TOUCHSCREENFEATURES/PROGRAMMING
TOUCH FOR
PROGRAMMABLE
THERMOSTAT
LuxLuxProThermostats
Mt. Laurel, NJ
• Home screen shows temp set points, date, time, room temp, humidity, and outdoor temp if using optional wireless temp transmitter.
• Touch the Screen anywhere to advance to Control Screen.
Heat Set Point
Cool Set Point
Outdoor Temp* RoomHumidity
NEW TOUCHSCREENFEATURES/PROGRAMMING
* With Use of Wireless Remote Transmitter
Mode Setting
Fan Setting
Run Program or Hold
Current time & date
LuxLuxProThermostats
Mt. Laurel, NJ
• The Control Screen is for the consumer to – make Temp changes, – set Humidity to Auto or
Manual, – set Dehumidifcation – set Fan mode– put t-stat in Hold or Run
Mode– access Installers Message.
• Press Home Screen button to go back to Home Screen.
• Press MENU to go to Main Programming Screen.
RUN PROG
AUTO
FAN AUTO
MENU --DHUM
++
68.072.0
45
46%70.0
HUMIDITY MANUAL
Run Program or Hold
Auto or Manual
Installers Message Home
Screen
Current Mode Blinks
Main Programming
NEW TOUCHSCREENFEATURES/PROGRAMMING
Adjust temp and dehumidification settings
Fan Auto, Fan Intermittent or Fan On.
Auto, Cool Heat, Emerg Heat or Off Current
room temp & humidity
HEAT
COOL
LuxLuxProThermostats
Mt. Laurel, NJ
• Main Menu Programming Screen allows owner to make adjustments, settings and programming choices.
• Push Date / Time Settings
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
LuxLuxProThermostats
Mt. Laurel, NJ
• Set date & time by pressing each button individually.
• Press MENU to go back to Main Programming Screen
NEW TOUCHSCREENFEATURES/PROGRAMMING
DATE / TIME SETTINGS
MENU
12 33
07 20 08
PM
2412
H M
H D Y
CLOCK
SET TIME / DATE
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Program Settings” to set daily temperature and fan settings.
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
LuxLuxProThermostats
Mt. Laurel, NJ
• Press day of week• 4 on/off periods per day. • Each day can be
programmed differently.• Fan can be set differently
for each period.• Each day can be copied
to the next.
NEW TOUCHSCREENFEATURES/PROGRAMMING
PROGRAM SETTINGS
TUMO WE TH FR SA SU
AM3007
1
MENUHEAT COOL
FAN AUTOEVENT
START
- +68.072.0
LuxLuxProThermostats
Mt. Laurel, NJ
• After completing each day’s program, when you push the next day, the user is asked if they want to copy to the next day.
• If YES, then you will continue to the following day and be asked the question again, etc.
• If NO, then you program that day as you wish and proceed on to all the days of the week.
• Press MENU when complete to go back to the Main Programming Screen.
NEW TOUCHSCREENFEATURES/PROGRAMMING
YES NO
COPY MONDAYSETTINGS
PROGRAM SETTINGS
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Energy Watch” to see HVAC energy consumption and cost to date.
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
LuxLuxProThermostats
Mt. Laurel, NJ
• Energy Watch shows energy consumption for up to 255 days based on parameters set in “Advanced Settings”.
• Owner can see energy usage and cost at anytime.
• Hit the RESET button to zero out.
ENERGY WATCH
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU
RESET
LAST 30 DAYS150 HRS COMP. 20 HRS FURN.120 HRS FAN290 HRS TOTAL
COST $20.30
LuxLuxProThermostats
Mt. Laurel, NJ
• By touching the Clean Screen button, you freeze the screen for 15 seconds so that you can wash/wipe it w/o changing any settings.
CLEAN SCREEN
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
Consult owners manual for maintenance & care
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Set Screen” to change screen settings.
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
LuxLuxProThermostats
Mt. Laurel, NJ
• Backlight – Can be set to Constant Light or Auto (touch the screen).
• Reverse – Change from B/W to W/B.
• Night Reverse - Set for Auto screen reverse (chgs at 9PM and 6AM).
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU 07
ON
ON
AUTO BACKLIGHT
REVERSE
NIGHT REVERSE
CONTRAST
SET SCREEN
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Vacation Settings” to set parameters for time & temperature while away from the home.
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
LuxLuxProThermostats
Mt. Laurel, NJ
• Input leave (BEGIN) date, return (END) date and heat/cool temp settings.
NEW TOUCHSCREENFEATURES/PROGRAMMING
VACATION SETTINGS
0830
09
09
HEAT COOL
20BEGIN
END
- +65.080.0
VACATION SETTINGS
08
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Filter Monitor” to see filter usage in days and to reset after changing filter.
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
LuxLuxProThermostats
Mt. Laurel, NJ
• Filter Monitor Screen shows how many days current filter has been used (based on fan run time).
• Reset button will set back to zero.
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU
RESET
FILTER
USED 15 DAYS
FILTER MONITOR
LuxLuxProThermostats
Mt. Laurel, NJ
• Push this button to toggle between “Humidify” or “Dehumidify” mode.
• More detailed settings for humidity control are available in Advanced Settings. (Installer settings)
HUMIDITY SETTINGS
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
LuxLuxProThermostats
Mt. Laurel, NJ
• Push & hold the Advanced Settings button for 5 seconds and the installer will be allowed to make additional and more detailed program settings.
• The following screen will appear when entering Advanced Settings:
ADVANCED SETTINGS
DATE / TIME SETTINGS
PROGRAM SETTINGS
ENERGY WATCH
DEHUMIDIFY
ADVANCED SETTINGS
VACATION SETTINGS
FILTER MONITOR
CLEAN SCREEN
SET SCREEN
NEW TOUCHSCREENFEATURES/PROGRAMMING
CAUTION: Altering the system properties in the ADVANCED SETTINGS may affect the performance of the HVAC system and should be performed only by a qualified installer.
LuxLuxProThermostats
Mt. Laurel, NJ
• Advanced Settings Screen allows installer to set:– Daylight Savings On/Off– Filter Days– Energy Usage Parameters– Celsius or Fahrenheit– Security level– Installers message
• Press FILTER to set Filter Monitor to Off/On & number of days to monitor.
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
INSTALL MESSAGE
SECU-RITY
FILTER
MENU
ENERGY WATCH
DAYLIGHT TIME
F
OFF
NEXT PAGE
LuxLuxProThermostats
Mt. Laurel, NJ
• Turn Filter Monitor Off or ON.
• An icon appears on the Home Screen when the Filter monitor is set to ON.
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU
OFF
FILTER MONITOR
FILTER MONITOR
ADVANCED SETTINGS
LuxLuxProThermostats
Mt. Laurel, NJ
• When you turn THE Filter Monitor ON, screen will then ask for the number of months (up to 6), based on fan run time, to notify consumer to change filter.
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU
2
CHANGE FILTER
FILTER MONITOR
ADVANCED SETTINGS
AFTER MONTH
Return to Advanced Settings Screen
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Energy Watch” to set parameters for tracking HVAC energy usage and cost.
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
INSTALL MESSAGE
SECU-RITY
FILTER
MENU
ENERGY WATCH
DAYLIGHT TIME
F
OFF
NEXT PAGE
LuxLuxProThermostats
Mt. Laurel, NJ
• Set consumption KW parameters for compressor, furnace & fan, and per hr KW cost.
• This allows consumer to watch on going HVAC energy costs by pushing the “Energy Watch” button on the Main Menu Screen.
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU 13
1
5
5 COMPRESSOR KW
FURNACE KW
FAN KW
C / KWHr
ENERGY WATCH
ADVANCED SETTINGS
Return to Advanced Settings Screen
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Security” to set level of screen lock preferred.
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
INSTALL MESSAGE
SECU-RITY
FILTER
MENU
ENERGY WATCH
DAYLIGHT TIME
F
OFF
NEXT PAGE
LuxLuxProThermostats
Mt. Laurel, NJ
• To turn Security on to FULL Lock or PARTIAL Lock, push OFF button.
• You will be asked for a Pin #. The default Pin # is 1111.
• To change your Pin # push Change Pin and follow the prompts.
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
MENU
OFF
SECURITY
SECURITY
ADVANCED SETTINGS
FULL LOCK
CHANGE PIN
LuxLuxProThermostats
Mt. Laurel, NJ
• Push the Lock button to toggle between FULL Lock and PARTIAL Lock
• FULL Lock completely locks out the thermostat from unauthorized use w/o the Pin #
• PARTIAL Lock only allows the changing of the temperature setpoint.
NEW TOUCHSCREEN
FEATURES/PROGRAMMING
MENU
OFF
SECURITY
SECURITY
ADVANCED SETTINGS
FULL LOCK
CHANGE PIN
Return to Advanced Settings Screen
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Install Message” to input installer message and set frequency of display.
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
INSTALL MESSAGE
SECU-RITY
FILTER
MENU
ENERGY WATCH
DAYLIGHT TIME
F
OFF
NEXT PAGE
LuxLuxProThermostats
Mt. Laurel, NJ
• Message of up to 42 characters.
• Message can be programmed to appear on a monthly basis.
• Message can also be accessed by consumer by pushing theicon button on the Control Screen.
NEW TOUCHSCREENFEATURES/PROGRAMMING
INSTALL MESSAGE
1 ABC
3 GHI
OK
For Service Call ABC Htg at 777-555-4321
ADVANCED SETTINGS
MENU
2 DEF
4 JKL
5 MNO
6 PQR
7 STU
8 VWX
9 YZ
0 :/-
LuxLuxProThermostats
Mt. Laurel, NJ
• Push “Next Page” to access Advanced settings for system type, cycles rates, staging temps, dual fuel, humidity and more…
NEW TOUCHSCREENFEATURES/PROGRAMMING
ADVANCED SETTINGS
INSTALL MESSAGE
SECU-RITY
FILTER
MENU
ENERGY WATCH
DAYLIGHT TIME
F
OFF
NEXT PAGE
LuxLuxProThermostats
Mt. Laurel, NJ
• Select type of HVAC system.
• Set Max Compressor Cycle Rate per Hr. (2 - 9)*
• Auto Change is minimum temp (dead band) difference between Heat/Cool set points. (1 – 5 )*
* factory settings are recommended
NEW TOUCHSCREENFEATURES/PROGRAMMING
ON
40+MENU
NEXT PAGE
PREV PAGE
HEAT PUMP 9
ELECTRIC FURNACE
HP CUT OFF
CUT TEMP
CYCLE RATE
3 AUTO CHNGE
• Heat Pump• 2 Stg HP• A/C• No Compressor
• Electric Furnace• Gas Furnace• 2 Stg Gas Furn.• Oil Furnace
ADVANCED SETTINGS
PUSH NEXT FOR FURTHER SETTING
LuxLuxProThermostats
Mt. Laurel, NJ
• Heat Pump Cut Off is for Dual Fuel applications. By turning the HP CUT OFF to ON, and setting the CUT TEMP (outside), the HP will shut down at that CUT TEMP and the gas furnace will take over.
• Press NEXT PAGE for further settings
NEW TOUCHSCREENFEATURES/PROGRAMMING
ON
36+MENU
NEXT PAGE
PREV PAGE
HEAT PUMP 9
ELECTRIC FURNACE
HP CUT OFF
CUT TEMP
CYCLE RATE
3 AUTO CHNGE
ADVANCED SETTINGS
DUAL FUEL
LuxLuxProThermostats
Mt. Laurel, NJ
• Allows heat pump to operate with the furnace by changing to the ON position.
• Press NEXT PAGE for further settings
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU
PREV PAGE
HP WHEN
NEXT PAGE
OFF
FURNACE ON
ADVANCED SETTINGS
DUAL FUEL
LuxLuxProThermostats
Mt. Laurel, NJ
• 1st Stage Differential is the temp difference from set point that the heat or cool initiates.
• 2nd Stage Differential is the temp difference from 1st stg set point & 2nd stg start-up.
• 3rd Stage…• Set the reversing valve to
energize in Heat or Cool depending on unit design
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU COOL
2
2
2 1ST STAGE DIF
2ND STAGE DIF
3RD STAGE DIF
OB ENERGIZED
NEXT PAGE
PREVPAGE
PUSH NEXT FOR FURTHER SETTING
ADVANCED SETTINGS
MULTI-STAGE DIFFERENTIAL
SETTINGS
Consult equipment manufacturer’s operation/installation manuals before setting these temperature settings.
LuxLuxProThermostats
Mt. Laurel, NJ
• This time setting brings on 2nd stage (heat or cool) if system has not been able to reach the 2nd stage temperature setpoint.
• This avoids excessive compressor run time by bringing on the 2nd stage and full system capacity to meet setpoint.
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU
PREV PAGE
IF STAGE 1 RUNS
NEXT PAGE 0
TURN ON STAGE 2
ADVANCED SETTINGS
MINUTES
MULTI-STAGE DIFFERENTIAL
SETTINGS
PUSH NEXT FOR FURTHER SETTING
Consult equipment manufacturer’s operation/installation manuals before setting these temperature settings.
LuxLuxProThermostats
Mt. Laurel, NJ
• Humidity Fan – When set to ON the fan will run when there is an independent call to humidify. When set to OFF, fan only runs during heating or cooling cycles.
• De-Humidity Fan – Same as above.
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU OFF
OFF
OFF
OFF HUM FAN
DH FAN
DH REVERSE
DHCONTCOMP
NEXT PAGE
PREVPAGE
ADVANCED SETTINGS
HUMIDITY CONTROL
LuxLuxProThermostats
Mt. Laurel, NJ
• DH REVERSE:
• ON - DH relay is normally closed when relative humidity is above DH set point.
• OFF - DH relay is normally open when relative humidity is below DH set point.
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU OFF
OFF
OFF
OFF HUM FAN
DH FAN
DH REVERSE
DHCONTCOMP
NEXT PAGE
PREVPAGE
ADVANCED SETTINGS
HUMIDITY CONTROL
LuxLuxProThermostats
Mt. Laurel, NJ
• DH CONTROL COMPRESSOR:
• ON - Thermostat will turn off the air conditioning if either the dehumidify set point or the temperature set point is reached, whichever comes first, both DH relay and compressor will turn off.
• OFF - DH relay is independent of compressor activity (DH becomes a spare relay and can be used for a variable speed fan or separate dehumidifier or air exchanger)
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU OFF
OFF
OFF
OFF HUM FAN
DH FAN
DH REVERSE
DHCONTCOMP
NEXT PAGE
PREVPAGE
ADVANCED SETTINGS
HUMIDITY CONTROL
LuxLuxProThermostats
Mt. Laurel, NJ
• This screen allows you to calibrate temperature or relative humidity if found to be off.
• Temperature accuracy is set at +/-1 degree. It can be adjusted +/- 9.5.
• Humidity accuracy is +/- 4%. It can be adjusted +/- 20%.
• Press NEXT PAGE for further settings
NEW TOUCHSCREENFEATURES/PROGRAMMING
MENU
PREV PAGE
HUM
0
ADVANCED SETTINGS
TEMP 0
0
++
LuxLuxProThermostats
Mt. Laurel, NJ
• HRV/ERV units can be controlled by simply connecting the DH terminal on the thermostat to the terminal DH of the HRV/ERV. Most HRV/ERV units will control properly with the DH REVERSE feature turned off (contact normally open).
• OPTION 1: In Advanced Settings choose DH ControlComp, set to ON then lower the temperature to a minimum safe set point, then set the desired de-humidity level. De- humidify will control the compressor (unless minimum temperature set point is reached) whichever comes first.
NEW TOUCHSCREENFEATURES/PROGRAMMING
De-humidification options for increasing comfort and efficiency
LuxLuxProThermostats
Mt. Laurel, NJ
• OPTION 2: Connect terminal DH to Y1 and set thermostat to de-humidify mode. Then regardless of temperature the de-humidification setting will have priority. Caution: This method will run the compressor until the de-humidification level is reached and may cause overcooling.
NEW TOUCHSCREENFEATURES/PROGRAMMING
De-humidification options for increasing comfort and efficiency
LuxLuxProThermostats
Mt. Laurel, NJ
• OPTION 3: Connect the DH terminal to a variable speed fan control, (set DH REVERSE to control the fan so that low speed is activated to de-humidify). This method provides maximum comfort while maintaining the temperature in cooling mode.
NEW TOUCHSCREENFEATURES/PROGRAMMING
De-humidification options for increasing comfort and efficiency
LuxLuxProThermostats
Mt. Laurel, NJ
• Optional Wireless Remote Outdoor Temperature Transmitter for PSPU7 multi-stage touchscreens. Used for DUAL FUEL & AUTOMATIC HUMIDITY CONTROL of central humidifier.
NEW TOUCHSCREENWireless Remote Temp Transmitter
Mounting Bracket
Indoor Receiver(plugs in at bottom of t-stat and mounts under t-stat cover)
Optional Outdoor Wireless Remote Temp Transmitter Kit #WTR064
LuxLuxProThermostats
Mt. Laurel, NJ
NEW TOUCHSCREENWireless Remote Indoor Receiver
Plug Indoor Receiver into plug located at bottom of PSPU t-stat
Indoor Receiver Unit installed
PSPU Thermostat Screen
Push Reset button on Indoor Receiver to initiate communication between Outdoor transmitter and Inside Receiver.
Plug antenna wire from Indoor Receiver into plug located at bottom right of PSPU t-stat
LuxLuxProThermostats
Mt. Laurel, NJ
WIRING LEGEND
TERMINAL EQUIPMENT STANDARD COLORY1 First Heat Pump YellowYellow
and/or ACG Fan GreenW2 First Stage Furnace WhiteOBW Reverse Valve or Orange
Second Stage FurnaceRH 24v Heat Transformer RedY2 Second Heat Pump Unknown
and/or ACC Common BlueH Humidity Control UnknownDH Dehumidify Control Unknown
Variable Fan ControlRC 24v Cool Transformer Unknown11 and 12 Not Used
NOTE: The above colors are standard in HVAC industry. The wiring should be confirmed before installation
12 11 RC DH H C Y2 RH OBW W2 G Y1
LuxLuxProThermostats
Mt. Laurel, NJ
TECHNICAL SUPPORT
• For more information, tech sheets, submittals, please refer to the Instruction or Engineering Manuals, or access the LuxPro web site at www.luxproproducts.com.
• Problems with installation or troubleshooting, please call our Technical Support team at (856) 234-8803 Ext. 7 (5:30AM – 2PM PST)
It is best if contractor is on jobsite when calling Tech Support
LuxLuxProThermostats
Mt. Laurel, NJ
LuxPro ’s Full Line of Residential & Light Comm’l Thermostats offer you the
best VALUE.Thanks for viewing our
Touchscreen Presentation